SOUND LEVEL METER MODEL NO.- ACM-SLM-2636
R
Weiber Sound Level Meter measures sound pressure level in industries, in environment surrounding us and
for noise produced by aircrafts. The current International standard for sound level meter performance is IEC
61672:2003 and this mandates the inclusion of an A-frequency-weighting filter and also describes other
frequency weightings of C and Z (zero) frequency weightings. The A-frequency-weighting is mandatory for
protection of workers against noise induced deafness.
Ÿ Pharmaceuticals
Ÿ Food Processing
Ÿ Electronics
Ÿ Surface Plating and coating
Ÿ Weiber offers sound level meter in the following different models, varying on the basis of the features it
offers :
Standard:This instrument is compatible with several standards of GB/T3785,IEC 651 Type 2,ANSIS 1.4 Type
2 .
USAGE
MODELS OF EQUIPMENT - SOUND LEVEL METER
PRODUCT DESCRIPTION
R
SOUND LEVEL METER
MODEL NO.- ACM-SLM-2636
TECHNICAL SPECIFICATIONS
OPTIONAL ACCESSORIES
236 x 63 x26 mm
170g (including batteries)
LCD display(10mm(0.4″) )
LP , Leq ,LN.
31.5Hz~8kHz
0.1db
1dB
Maximum value (30groups)
Low battery indicator
Electron
RS232C
4x1.5v AAA (UM-4 battery)
Size
Weight
Display
Function
Frequency Range
Measurement Range
LP:30~130dB (A)
35~130dB (C)
35~130 dB (F)
Leq :30-130dB
LN .: 0-100%
Resolution
Accarcy
Memory
Indicator
Alarm
Connector
Power Supply
ND9 sound level meter calibrator
Rs-232 and software
External Relay
R
Surface cleanliness is essential when applying the replication methods; it is less significant when viewing the
specimen directly by the scanning electron microscope. Surface damage any analytical measurement should
not change the sample being measured. If the condition of the measurement or the probe with which the
analysis is being done changes or damages the sample, the results of the analysis will be incorrect.
Ÿ 4 digit LCD with mode indicators
LCD displays updates every 3 seconds, showing the average for the past 30
second time period at normal levels.
Ÿ Wipe Test Plate
Ÿ External scintillation probe
PRODUCT FEATURES
TECHNICAL FEATURES
OPTIONAL ACCESSORIES
R
mR/hr
CPM
Total
mSv / hr
CPS
Efficiency
Sensitivity
Accuracy
Timer :
Can set 1-10 minute sampling periods in 1-minute
increments,
10-50 minute sampling periods in 10-minute
increments, and
1-24 hour sampling periods in 1-hour increments
Temperature Range
Power
.001 to 100.0
0 to 300,000
1 to 9,999,000 counts
.01 to 1,000
0 to 5,000
Sr-90 (546KeV, 2.3MeV bmax
3500 CPM / mR / hr referenced to Cs-137
±15% 0-50 mR / hr; ± - 20 % 50 - 100 mR / hr
-10 ºC to +50C (14 ºF to 122 ºF)
One 9-volt alkaline battery; battery life is minimum 200
hours at normal background, minimum 24 hours at 1
mR / hr
OPERATING RANGE
R
www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com
SALES OFFICE (HONG KONG)
SHOWROOM
SALES OFFICE (RUSSIA)
Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,
Sheung Wan, Hong Kong (PRC)
Tel.: 0086-13929598046 0086- 18922303099
E-mail.: [email protected]
J-284 Sector 1 Bawana Industrial Estate, Bawana,
Delhi, INDIA-110039
Tel.: 0091-0-9312219738 (M) +91- 9717741167
E-mail.: [email protected]
Inmed Trade Street Ozerkovsky Embankment,
Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: [email protected]
Tel.: 0049- 79592345 | Email: [email protected]
TECHNOCRACY PVT. LTD.
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485
WHO: GMP Products | GLP Compliant Products
SALES OFFICE (INDIA)
thOffice no. 506 & 507, 5 Floor, Plot no.- C-9,
Pearls Best Height-II, Netaji Subhash Place,
Pitam Pura, Delhi- 110034
Land Line No.: +91 - 11- 47619688,
Fax: +91-11-47619788
E-mail.: [email protected]
Top Related