7/28/2019 Smoke Detector Using Zigbee
1/82
1
ORGANIZATIONAL PROFILE
The National Small Industries Corporation Limited (NSIC) was established in
1955 by the Government of India with a view to promote, aid and foster the growth of Small
Industries in the country. NSIC continues to remain at the forefront, with it's various programs
and projects, to assist the small-scale sector in the country.
Over a period of four decades of this rescission, growth and development of
small-scale sector, it has proved its strength within the country and abroad dynamically, showing
its progressive attitude towards modernization, up gradation of technology, quality
consciousness, strengthening linkages with large and medium scale enterprises and boosting
exports of products from Small Enterprises. The small-scale sector continues to remain an
important instrument for enterprise-building, dispersal of industries for even regional economic
development and employment generation. NSIC has been successfully able to plan its assigned
role in this endeavor.
Due to changed industrial scenario and gradual globalization of the economy, small-scale
sector has to face stiff competition as the insulated and protected market conditions are no more
going to be available to it. To enable the small-scale industry to meet this challenge, NSIC has
already initiated various steps so that SSI's can play their due role, even during polarization of
various economic forces.
A SPECTRUM OF ACTIVITIES
NSIC provides diversified support through its wide spectrum of programs to TSC to cater
to their different needs related to multi-products and multi-locations markets. It has adopted a
multi-pronged approach to effectively serve the various needs of TSC. Assistance by NISC to
Small Scale Units to sell their goods and services to government departments and agencies,
through 'Single Point Registration Scheme', provides a vast marketing opportunity.
The corporation also arranges indigenous as well as imported raw materials and parts
to ensure that the production cycle of SSI's continues without break and they are able to produce
high quality products. But that's not all. There is a lot more to NSIC. The organization operates
7/28/2019 Smoke Detector Using Zigbee
2/82
2
Hire purchase and Equipment Leasing Schemes for providing machinery and equipment at
doorsteps of the entrepreneurs. These schemes not only have been able to generate a class of
First Generation Entrepreneurs to set up enterprises with minimum investment, the schemes have
also acted as stimulants to the existing entrepreneur for expansion, diversification, modernization
and technology up gradation.
Though a chain of five NSIC Technical Service Centers are located at different parts of
the country, NSIC offers workshops, testing laboratories and common facilities to the
entrepreneurs and their workmen are provided with avenues for skill up gradation through
training in various technical trades. To encourage exports, NSIC has set up Software Technology
Parks providing complete infrastructure to enable small entrepreneurs to undertake Software
exports.
ACTIVITIES
Common facilities
Prototype development
Technology Transfer
Human Resource DevelopmentPlacements
Seminars and Workshops
ASSISSTING COUNTRIES WORLDWIDE
NSIC is committed to accelerate the growth of the small-scale sector not only in
India but also in similar countries worldwide NSICs efforts in assisting other countries with
infrastructure facilities and support service has been worthy.
7/28/2019 Smoke Detector Using Zigbee
3/82
3
.
CHAPTER-1
GENERAL OVERVIEW
7/28/2019 Smoke Detector Using Zigbee
4/82
4
GENERAL OVERVIEW
1.1 INTRODUCTION:
Technology is the word coined for the practical application of scientific knowledge in the industry.
The advancement in technology cannot be justified unless it is used for leveraging the users
purpose. Technology, is today, imbibed for accomplishment of several tasks of varied complexity,
in almost all walks of life.
The society as a whole is exquisitely dependent on science and technology.
Technology has played a very significant role in improving the quality of life. One way through
which this is done is by automating several tasks using complex logic to simplify the work.
1.2 AIM:
Vehicle access control system is an important sub-system of the intelligentized residence
section. Today, in a growing emphasis on personal and property safety, the control of vehicles'
access authorization and the management of the vehicles' access authority, access time and
access method via computer, is safe and convenient. This paper describes a set of vehicle access
control system based on ZigBee wireless technology. In this system, ZigBee coordinator and its
terminal nodes installed respectively in the entrance of the district and the vehicles, together
form a ZigBee wireless sensor network. This paper mainly introduces the overall structure,
hardware platform and software design of this system. The implementation and performance
tests of this system are fairly good.
7/28/2019 Smoke Detector Using Zigbee
5/82
5
1.3 METHODOLOGY:
The above figure gives the pictorial representation of the procedure followed in the project
development.
In the specifications stage, the requirements of the model were identified. In order to
identify the requirements, literature survey was carried out.
The identified requirements and the specifications of the model were then analyzed to
identify whether or not they were viable. If any of the specifications seemed impracticable, the
specifications were reviewed.
Once the viable specifications were identified, the design of the product was developed.
A set of all possible test cases was also prepared simultaneously.
Specifications Analysis ProductDesign
TestCases
High-level
Desi n
Low-level
Desi n
Coding &Unit
Testing
IntegrationSystem
TestDocumentation
TestDesign
Successful
Failure
7/28/2019 Smoke Detector Using Zigbee
6/82
6
The high level design document gives an overview of the design details.
The low level design document contains the intricate details of the product design.
The project was then divided into separate modules and each module was individually
soldered, coded and tested.
All the tested modules were then integrated. The integrated module was then tested for
the set of all possible test cases. In case the integrated module didnt work fora certain test case, the
specifications were reviewed accordingly.
In general, after every stage in project development, the specifications were reviewed.
After the integrated module satisfied all the test cases, different stages of the project were
documented.
1.4 SIGNIFICANCE OF PROJECT WORK:
During the course of our project we developed a multi system controller that is capable of
controlling devices that work on sensor supplies satisfactorily. We have developed a model that
gives a demo of industrial automation.
7/28/2019 Smoke Detector Using Zigbee
7/82
7
CHAPTER-2
INTRODUCTION
7/28/2019 Smoke Detector Using Zigbee
8/82
8
INTRODUCTION
2.1 INTRODUCTION TO EMBEDDED SYSTEMS:
2.1.1 EMBEDDED SYSTEMS:An embedded system is a specialized computer system that is housed in a large system in order to
carry out certain specific applications. Some embedded systems include operating systems and most
are so specialized such that the entire logic can be implemented as a single program.
2.1.2 APPLICATIONS OF EMBEDDED SYSTEMS:
Industrial machines Automobiles
Medical equipment
Cameras
Household appliances
Airplanes
Vending machines
Toys etc
2.2INTRODUCTION TO ZIGBEE
ZigBee coordinator(ZC): The most capable device, the coordinator forms the root of the
network tree and might bridge to other networks. There is exactly one ZigBee coordinator in
each network since it is the device that started the network originally. It is able to store
information about the network, including acting as the Trust Centre & repository for security
keys.
ZigBee Router (ZR): As well as running an application function a router can act as an
intermediate router, passing data from other devices.
ZigBee End Device (ZED): Contains just enough functionality to talk to the parent node (either
the coordinator or a router); it cannot relay data from other devices. This relationship allows the
node to be asleep a significant amount of the time thereby giving long battery life. A ZED
7/28/2019 Smoke Detector Using Zigbee
9/82
9
requires the least amount of memory, and therefore can be less expensive to manufacture than a
ZR or ZC.
Protocols
The protocols build on recent algorithmic research (Ad-hoc On-demand Distance Vector,
neuRFon) to automatically construct a low-speed ad-hoc network of nodes. In most large
network instances, the network will be a cluster of clusters. It can also form a mesh or a single
cluster. The current profiles derived from the ZigBee protocols support beacon and non-beacon
enabled networks.
In non-beacon-enabled networks (those whose beacon order is 15), an unslotted CSMA/CA
channel access mechanism is used. In this type of network, ZigBee Routers typically have their
receivers continuously active, requiring a more robust power supply. However, this allows for
heterogeneous networks in which some devices receive continuously, while others only transmit
when an external stimulus is detected. The typical example of a heterogeneous network is a
wireless light switch: the ZigBee node at the lamp may receive constantly, since it is connected
to the mains supply, while a battery-powered light switch would remain asleep until the switch is
thrown. The switch then wakes up, sends a command to the lamp, receives an acknowledgment,
and returns to sleep. In such a network the lamp node will be at least a ZigBee Router, if not the
ZigBee Coordinator; the switch node is typically a ZigBee End Device.
In beacon-enabled networks, the special network nodes called ZigBee Routers transmit periodic
beacons to confirm their presence to other network nodes. Nodes may sleep between beacons,
thus lowering theirduty cycle and extending their battery life. Beacon intervals may range from
15.36 milliseconds to 15.36 ms * 214 = 251.65824 seconds at 250 kbit/s, from 24 milliseconds to
24 ms * 214 = 393.216 seconds at 40 kbit/s and from 48 milliseconds to 48 ms * 214 = 786.432
seconds at 20 kbit/s. However, low duty cycle operation with long beacon intervals requires
precise timing, which can conflict with the need for low product cost.
http://en.wikipedia.org/wiki/AODVhttp://en.wikipedia.org/wiki/NeuRFonhttp://en.wikipedia.org/wiki/CSMA/CAhttp://en.wikipedia.org/wiki/Wireless_light_switchhttp://en.wikipedia.org/wiki/Duty_cyclehttp://en.wikipedia.org/wiki/Kbit/shttp://en.wikipedia.org/wiki/Kbit/shttp://en.wikipedia.org/wiki/Duty_cyclehttp://en.wikipedia.org/wiki/Wireless_light_switchhttp://en.wikipedia.org/wiki/CSMA/CAhttp://en.wikipedia.org/wiki/NeuRFonhttp://en.wikipedia.org/wiki/AODV7/28/2019 Smoke Detector Using Zigbee
10/82
10
In general, the ZigBee protocols minimize the time the radio is on so as to reduce power use. In
beaconing networks, nodes only need to be active while a beacon is being transmitted. In non-
beacon-enabled networks, power consumption is decidedly asymmetrical: some devices are
always active, while others spend most of their time sleeping.
ZigBee devices are required to conform to the IEEE 802.15.4-2003 Low-Rate Wireless Personal
Area Network (WPAN) standard. The standard specifies the lowerprotocol layersthe physical
layer(PHY), and the medium access control (MAC) portion of the data link layer(DLL). This
standard specifies operation in the unlicensed 2.4 GHz, 915 MHz and 868 MHz ISM bands. In
the 2.4 GHz band there are 16 ZigBee channels, with each channel requiring 5 MHz of
bandwidth. The center frequency for each channel can be calculated as, FC = (2405 + 5 * (ch -
11)) MHz, where ch = 11, 12, ..., 26.
The radios use direct-sequence spread spectrum coding, which is managed by the digital stream
into the modulator. BPSK is used in the 868 and 915 MHz bands, and orthogonal QPSK that
transmits two bits per symbol is used in the 2.4 GHz band. The raw, over-the-air data rate is 250
kbit/sperchannel in the 2.4 GHz band, 40 kbit/s per channel in the 915 MHz band, and 20 kbit/s
in the 868 MHz band. Transmission range is between 10 and 75(up to 1500meteres for zigbee
pro.)meters (33 and 246 feet), although it is heavily dependent on the particular environment.
The maximum output power of the radios is generally 0 dBm (1 mW).
The basic channel access mode is "carrier sense, multiple access/collision avoidance"
(CSMA/CA). That is, the nodes talk in the same way that people converse; they briefly check to
see that no one is talking before they start. There are three notable exceptions to the use of
CSMA. Beacons are sent on a fixed timing schedule, and do not use CSMA. Message
acknowledgments also do not use CSMA. Finally, devices in Beacon Oriented networks that
have low latency real-time requirements may also use Guaranteed Time Slots (GTS), which by
definition do not use CSMA.
http://en.wikipedia.org/wiki/Protocol_(computing)http://en.wikipedia.org/wiki/Layerhttp://en.wikipedia.org/wiki/Physical_layerhttp://en.wikipedia.org/wiki/Media_Access_Controlhttp://en.wikipedia.org/wiki/Data_link_layerhttp://en.wikipedia.org/wiki/Hertzhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/ISM_bandhttp://en.wikipedia.org/wiki/Hertzhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/Direct-sequence_spread_spectrumhttp://en.wikipedia.org/wiki/BPSKhttp://en.wikipedia.org/wiki/QPSKhttp://en.wikipedia.org/wiki/Kilobithttp://en.wikipedia.org/wiki/Secondhttp://en.wikipedia.org/wiki/Channel_(communications)http://en.wikipedia.org/wiki/Meterhttp://en.wikipedia.org/wiki/Foot_(length)http://en.wikipedia.org/wiki/DBmhttp://en.wikipedia.org/wiki/Carrier_Sense_Multiple_Accesshttp://en.wikipedia.org/wiki/Carrier_Sense_Multiple_Accesshttp://en.wikipedia.org/wiki/DBmhttp://en.wikipedia.org/wiki/Foot_(length)http://en.wikipedia.org/wiki/Meterhttp://en.wikipedia.org/wiki/Channel_(communications)http://en.wikipedia.org/wiki/Secondhttp://en.wikipedia.org/wiki/Kilobithttp://en.wikipedia.org/wiki/QPSKhttp://en.wikipedia.org/wiki/BPSKhttp://en.wikipedia.org/wiki/Direct-sequence_spread_spectrumhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/Hertzhttp://en.wikipedia.org/wiki/ISM_bandhttp://en.wikipedia.org/wiki/Megahertzhttp://en.wikipedia.org/wiki/Hertzhttp://en.wikipedia.org/wiki/Data_link_layerhttp://en.wikipedia.org/wiki/Media_Access_Controlhttp://en.wikipedia.org/wiki/Physical_layerhttp://en.wikipedia.org/wiki/Layerhttp://en.wikipedia.org/wiki/Protocol_(computing)7/28/2019 Smoke Detector Using Zigbee
11/82
11
Software and Hardware
The software is designed to be easy to develop on small, inexpensive microprocessors. The radio
design used by ZigBee has been carefully optimized for low cost in large scale production. It has
few analog stages and uses digital circuits wherever possible.
Even though the radios themselves are inexpensive, the ZigBee Qualification Process involves a
full validation of the requirements of the physical layer. This amount of concern about the
Physical Layer has multiple benefits, since all radios derived from that semiconductor mask set
would enjoy the same RF characteristics. On the other hand, an uncertified physical layer that
malfunctions could cripple the battery lifespan of other devices on a ZigBee network. Where
other protocols can mask poor sensitivity or other esoteric problems in a fade compensation
response, ZigBee radios have very tight engineering constraints: they are both power and
bandwidth constrained. Thus, radios are tested to the ISO 17025 standard with guidance given by
Clause 6 of the 802.15.4-2006 Standard. Most vendors plan to integrate the radio and
microcontroller onto a single chip.
Controversy
An academic research group has examined the Zigbee address formation algorithm in the 2006
specification, and argues[6] that the network will isolate many units that could be connected. The
group proposed an alternative algorithm with similar complexity in time and space.
A white paperpublished by a European manufacturing group (associated with the development
of a competing standard, Z-Wave) claims that wireless technologies such as ZigBee, which
operate in the 2.4 GHz RF band, are subject to significant interference - enough to make them
unusable.[7] It claims that this is due to the presence of other wireless technologies like Wireless
LAN in the same RF band. The ZigBee Alliance released a white paper refuting these claims.[8]
After a technical analysis, this paper concludes that ZigBee devices continue to communicate
effectively and robustly even in the presence of large amounts of interference.
http://en.wikipedia.org/wiki/Analog_circuithttp://en.wikipedia.org/wiki/Digital_circuithttp://en.wikipedia.org/wiki/ISO_17025http://en.wikipedia.org/wiki/ZigBee#cite_note-5#cite_note-5http://en.wikipedia.org/wiki/White_paperhttp://en.wikipedia.org/wiki/Z-Wavehttp://en.wikipedia.org/wiki/ZigBee#cite_note-Zig_WLAN_Interference-6#cite_note-Zig_WLAN_Interference-6http://en.wikipedia.org/wiki/Wireless_LANhttp://en.wikipedia.org/wiki/Wireless_LANhttp://en.wikipedia.org/wiki/ZigBee#cite_note-Zig_WLAN_Interference_Refute-7#cite_note-Zig_WLAN_Interference_Refute-7http://en.wikipedia.org/wiki/ZigBee#cite_note-Zig_WLAN_Interference_Refute-7#cite_note-Zig_WLAN_Interference_Refute-7http://en.wikipedia.org/wiki/Wireless_LANhttp://en.wikipedia.org/wiki/Wireless_LANhttp://en.wikipedia.org/wiki/ZigBee#cite_note-Zig_WLAN_Interference-6#cite_note-Zig_WLAN_Interference-6http://en.wikipedia.org/wiki/Z-Wavehttp://en.wikipedia.org/wiki/White_paperhttp://en.wikipedia.org/wiki/ZigBee#cite_note-5#cite_note-5http://en.wikipedia.org/wiki/ISO_17025http://en.wikipedia.org/wiki/Digital_circuithttp://en.wikipedia.org/wiki/Analog_circuit7/28/2019 Smoke Detector Using Zigbee
12/82
12
.Advantages:
low cost allows the technology to be widely deployed in wireless control and monitoring
applications.
low power-usage allows longer life with smaller batteries,.
mesh networking provides high reliability and larger range.
Applications:
Home Automation
ZigBee Smart Energy
Telecommunication Applications
Personal Home
Hospital Care
7/28/2019 Smoke Detector Using Zigbee
13/82
13
CHAPTER-3
MICROCONTROLLER
7/28/2019 Smoke Detector Using Zigbee
14/82
14
MICROCONTROLLER
3.1 INTRODUCTION:
A microcontroller is a computer on a chip. It is an integrated chip that is usually a part of an
embedded system. It is a microprocessor that is meant to be more self contained, independent andyet function as a tiny, dedicated computer. It lays emphasis on high integration, low power
consumption, self sufficiency and cost effectiveness.
It is typically designed using the CMOS (complementary metal oxide semiconductor) technology
and has the following features:
a central processing unit
discrete input and output pins
serial input/output ports(UARTs)
peripherals such as timers, counters
RAM,ROM,EPROM,Flash Memory(EEPROM)
Clock generator
May include analog to digital converters
In-circuit programming and debugging support
Micro controller
Memory
(RAM/ROM)
I/O ports
Peripherals
7/28/2019 Smoke Detector Using Zigbee
15/82
15
3.2 ADVANTAGES:
Design with microcontrollers has the following advantages:
It has low overall system cost as all the peripherals are integrated onto a single chip.
The product size is small, therefore the product is handy.
System design and troubleshooting is simple.
Since the peripherals are integrated on the same chip, the system is reliable.
Additional RAM and ROM can be easily interfaced as and when required.
Microcontrollers with on-chip ROM provides a software security feature.
3.3 ATMEL 89S52:
ATMEL 89C51 is a low power, high performance CMOS 8 bit microcomputer with 4K bytes of
flash programmable and erasable read only memory (PEROM).The device is manufactured using
Atmels high density, non volatile memory technology and is compatible with industry standard
MCS-51 instruction set. It provides highly flexible and cost effective solution to many embedded
control applications.
3.4 FEATURES OF ATMEL 89S52:
It has 4K bytes of in-system reprogrammable flash memory (1000 write/erase cycles).
Fully static operation: 0-24 MHz
Three level program memory lock
128 bytes internal RAM
32 programmable I/O lines(4 ports)
Two 16 bit timers/counters
Six interrupt sources
Programmable serial channel
Low power idle and Power down modes
8 bit CPU optimized for controlled applications
64 K of external program memory
Full duplex UART
7/28/2019 Smoke Detector Using Zigbee
16/82
16
3.5 BLOCK DIAGRAM OF THE MICROCONTROLLER:
Fig 3.5 Block Diagram of the Microcontroller
7/28/2019 Smoke Detector Using Zigbee
17/82
17
3.6 DESCRIPTION OF BLOCK DIAGRAM:
3.6.1 CENTRAL PROCESSING UNIT (CPU):The microcontroller consists of 8 bit ALU with associated registers like register A,
register B,Program status word(PSW),Stack pointer(SP) ,a 16 bit program counter(PC) and a 16 bit
data pointer register(DTPR).
3.6.2ARITHMETIC LOGIC UNIT(ALU):
The ALU performs arithmetic and logic functions on 8 bit variables. An important and unique
feature of the microcontroller architecture is that theALU can manipulate 1 bit as well as 8 bit data
types. It performs the Operations over the operands held by the temporary registers TMP1 and
TMP2.The temporary registers cannot be accessed by the user.
3.6.3 ACCUMULATOR (ACC):
It is referred to as register A or Acc.It is an 8 bit register. It holds the source
operand and stores the result of arithmetic operations. It is used as the source or destination register
for logical operations. It is either explicitly or implicitly specified in the instructions.
3.6.4 B REGISTER:
It is a special function register. It can be used to store one of the operands in multiply
and divide instructions. For all other instructions it is used as a scratch pad.
3.6.5 PROGRAM STATUS WORD (PSW):
It is one of the special function registers .It is an 8 bit register. It is a set of
Flags that indicate the status of the microcontroller.
CARRY BIT (CY):
This bit holds the carry bit in case of arithmetic operations. It also serves the purpose of
accumulator in case of Boolean operations. It is set to one when there is a carry out from the D7 bit.
It can also be rest or cleared through instructions.
CY AC FO RS1 RS0 OV -- P
7/28/2019 Smoke Detector Using Zigbee
18/82
18
AUXILLARY CARRY (AC):
It is used in BCD operations usually. This bit is raised when a carry occurs from lower nibble to the
higher nibble during arithmetic operations on BCD numbers.
FLAG 0 (F0):Flag 0 is available to the user for general purpose.
REGISTER SELECT BITS (RS1 AND RS0):
The two bits RS1 and RS0 are used to select one of the four available register banks
As below:
OVERFLOW FLAG (OF):
The overflow flag was created specifically for the purpose of informing the programmer that the
result of the signed number operation is erroneous. If the result of an operation on signed numbers
is too big for a register, an overflow has occurred and the programmer must be notified.
PARITY (P):
The parity bit reflects the number of 1s in the accumulator.
P=0 implies that accumulator contains an even number of 1s.
P=1 implies that the accumulator contains odd number of 1s.
D1 bit is a user definable flag and is reserved for future use.
3.5.6 SPECIAL FUNCTION REGISTER BANK (SFR):
It is a set of special function registers that can be addressed using their respective addresses
allotted to them. The addresses lie in the range 80H-FFH.
RS1 RS0 REGISTER BANKS ADDRESS
0 0 0 00H-07H
0 1 1 08H-0FH
1 0 2 10H-17H
1 1 3 18H-1FH
7/28/2019 Smoke Detector Using Zigbee
19/82
19
3.5.7 INPUT-OUTPUT (I/O) PORTS (P0-P3):
These four latches-drivers pairs have been allotted to the four parallel I/O ports. These latches have
been allotted addresses in the special function register bank. Using these allotted addresses, the user
can communicate with the ports.
3.5.8 BUFFER:
It is a special function register and consists of two registers namely transmit buffer and the
receive buffer. The transmit buffer receives data parallely and transmits serially. The receive buffer
on the other hand is serial in parallel out register.
3.5.9 TIMING AND CONTROL UNIT:
It derives the timing and control information required for the internal operation of the circuit
and the control information required for controlling the external bus.
3.5.10 OSCILLATOR:
It generates the basic timing clock signal required for the operation of the circuit using a
crystal oscillator connected externally.
3.5.11 EPROM AND PROGRAM ADDRESS REGISTER:
These blocks provide on chip EPROM and a mechanism to internally address the EPROM.
3.5.12 RAM AND RAM ADDRESS REGISTER:
They provide 128 bytes of RAM and a mechanism to internally address the RAM
7/28/2019 Smoke Detector Using Zigbee
20/82
20
3.6 PIN DESCRIPTION OF AT89S52:
3.7 Pin Description
3.7.1VCC (PIN 40)
Supply voltage.
3.7.2 GND (PIN 20)
Ground.
3.7.3 Port 0 (PIN 32-39)
Port 0 is an 8-bit open drain bidirectional I/O port. As an output port, each pin can sink eight
TTL inputs. When 1s are written to port 0 pins, the pins can be used as high-impedance inputs. Port
0 can also be configured to be the multiplexed low-order address/data bus during accesses to
external program and data memory. In this mode, P0 has internal pull-ups. Port 0 also receives the
code bytes during Flash programming and outputs the code bytes dur-ing program verification.
External pull-ups are required during program verification.
3.7.4 Port 1 (PIN 1-8)
Port 1 is an 8-bit bidirectional I/O port with internal pull-ups. The Port 1 output buffers can
sink/source four TTL inputs. When 1s are written to Port 1 pins, they are pulled high by the inter-
nal pull-ups and can be used as inputs. As inputs, Port 1 pins that are externally being pulled low
7/28/2019 Smoke Detector Using Zigbee
21/82
21
will source current (IIL) because of the internal pull-ups. In addition, P1.0 and P1.1 can be
configured to be the timer/counter 2 external count input (P1.0/T2) and the timer/counter 2 trigger
input (P1.1/T2EX), respectively, as shown in the following table. Port 1 also receives the low-order
address bytes during Flash programming and verification.
3.7.5 Port 2 (PIN 21-28)
Port 2 is an 8-bit bidirectional I/O port with internal pull-ups. The Port 2 output buffers can
sink/source four TTL inputs. When 1s are written to Port 2 pins, they are pulled high by the internal
pull-ups and can be used as inputs. As inputs, Port 2 pins that are externally being pulled low will
source current (IIL) because of the internal pull-ups. Port 2 emits the high-order address byte during
fetches from external program memory and during accesses to external data memory that use 16-bit
addresses (MOVX @ DPTR). In this application, Port 2 uses strong internal pull-ups when emitting
1s. During accesses to external data memory that use 8-bit addresses (MOVX @ RI), Port 2 emits
the contents of the P2 Special Function Register. Port 2 also receives the high-order address bits
and some control signals during Flash program-ming and verification. Port Pin Alternate Functions
P1.0 T2 (external count input to Timer/Counter 2), clock-out P1.1 T2EX (Timer/Counter 2
capture/reload trigger and direction control) P1.5 MOSI (used for In-System Programming) P1.6
MISO (used for In-System Programming) P1.7 SCK (used for In-System Programming)
3.7.6 Port 3 (PIN 10-17)
Port 3 is an 8-bit bidirectional I/O port with internal pull-ups. The Port 3 output buffers can
sink/source four TTL inputs. When 1s are written to Port 3 pins, they are pulled high by the internal
pull-ups and can be used as inputs. As inputs, Port 3 pins that are externally being pulled low will
source current (IIL) because of the pull-ups. Port 3 receives some control signals for Flash
programming and verification. Port 3 also serves the functions of various special features of the
AT89S52, as shown in the following table.
3.7.7 RST (PIN 9)Reset input. A high on this pin for two machine cycles while the oscillator is running resets the
device. This pin drives high for 98 oscillator periods after the Watchdog times out. The DISRTO bit
in SFR AUXR (address 8EH) can be used to disable this feature. In the default state of bit DISRTO,
the RESET HIGH out feature is enabled.
3.7.8 ALE/PROG (PIN 30)
7/28/2019 Smoke Detector Using Zigbee
22/82
22
Address Latch Enable (ALE) is an output pulse for latching the low byte of the address during
accesses to external memory. This pin is also the program pulse input (PROG) during Flash
programming. In normal operation, ALE is emitted at a constant rate of 1/6 the oscillator frequency
and may be used for external timing or clocking purposes. If desired, ALE operation can be
disabled by setting bit 0 of SFR location 8EH. With the bit set, ALE is active only during a MOVX
or MOVC instruction. Otherwise, the pin is weakly pulled high. Setting the ALE-disable bit has no
effect if the microcontroller is in external execution mode. Port Pin Alternate FunctionsP3.0 RXD
(serial input port) P3.1 TXD (serial output port) P3.2 INT0 (external interrupt 0) P3.3 INT1
(external interrupt 1) P3.4 T0 (timer 0 external input) P3.5 T1 (timer 1 external input) P3.6 WR
(external data memory write strobe) P3.7 RD (external data memory read strobe)
3.7.9 PSEN (PIN 29)
Program Store Enable (PSEN) is the read strobe to external program memory. When the AT89S52
is executing code from external program memory, PSEN is activated twice each machine cycle,
except that two PSEN activations are skipped during each access to exter-nal data memory.
3.7.10 EA/VPP (PIN 31)
External Access Enable. EA must be strapped to GND in order to enable the device to fetch code
from external program memory locations starting at 0000H up to FFFFH. Note, however, that if
lock bit 1 is programmed, EA will be internally latched on reset. EA should be strapped to VCC for
internal program executions. This pin also receives the 12-volt programming enable voltage (VPP)
during Flash programming.
3.7.11 XTAL1 (PIN 19)
Input to the inverting oscillator amplifier and input to the internal clock operating circuit.
3.7.12 XTAL2 (PIN 18)
Output from the inverting oscillator amplifier.
7/28/2019 Smoke Detector Using Zigbee
23/82
23
CHAPTER-4
GAS SENSOR
7/28/2019 Smoke Detector Using Zigbee
24/82
24
GAS SENSOR
INTRODUCTION:
A CO gas sensor according to the present invention includes a gas collecting container for
collecting a measured gas therein; a detecting section provided within the gas collecting
container and having at least a pair of electrodes positioned through electrolyte; and a voltage
applying apparatus for applying voltage to the detecting section. One of the electrodes of the
detecting section is a detection electrode having the capability of adsorbing at least one of
hydrogenous gas and CO gas when a voltage is applied and then oxidizing it. By introducing a
measured gas into a gas collecting container of the CO gas sensor and carrying out electrolysis
according to a potential sweep method or a pulse method with the measured gas being in contact
with the detecting section, a CO gas concentration in the measured gas can be measured based on
an electrical current value obtained at the detecting section and changes of the electrical current
with elapse of time. According to the CO gas sensor of the present invention, it is possible to
accurately carry out detection and measurement of the concentration of CO gas when CO gas is
to be detected or measured even in a gaseous atmosphere containing a relatively large amount of
hydrogen gas and CO2 gas.
DESCRIPTION:
FIELD OF THE INVENTION
The present invention relates to a CO gas sensor for measuring the concentration of CO gas
contained in a gaseous phase and to a method of measuring the concentration of CO gas, and in
particular relates to a CO gas sensor for measuring the concentration of CO gas in a gaseous
atmosphere containing relatively high concentrations of hydrogen gas and carbon dioxide gas, afuel cell power generating apparatus equipped with such CO gas sensor, and a method of
measuring the concentration of CO gas.
7/28/2019 Smoke Detector Using Zigbee
25/82
25
BACKGROUND ART
In many cases, hydrogen gas is used as a fuel gas for fuel cells. As such hydrogen gas, a
hydrogen gas rich reforming gas which is obtained by reforming methanol or the like is used.
When manufacturing such a reforming gas, a tiny amount of carbon monoxide (CO), namely
several tens ppm to several hundred ppm, is present as impurities. For this reason, when such a
reforming gas is used as a fuel gas for a fuel cell, the CO gas is adsorbed on the surface of the
platinum catalyst of the fuel cell electrodes, thus hindering ionization of the hydrogen gas and
lowering the output of the fuel cell. In order to take appropriate measures to counter such a
problem caused by the CO gas, it is necessary to continuously monitor the concentration of CO
gas in the reforming gas used in the fuel cell.
Conventionally, as for the most commonly used CO gas sensor, there are known a controlled
potential analysis type CO gas sensor and a semiconductor type CO gas sensor. However, for the
reasons given below, neither of these CO gas sensors is appropriate for detecting CO gas in a
reforming gas.
Namely, the reforming gas contains hydrogen gas used as a fuel in the fuel cell for the amount of
about 75% thereof. In comparison with this, the reforming gas contains a relatively tiny amount
of CO gas as described above. Therefore, it becomes necessary to detect or measure CO gas in a
hydrogen gas atmosphere containing a relatively large amount of hydrogen gas. However, in the
case where the concentration of CO gas is measured in such a hydrogen gas rich atmosphere
using these CO gas sensors, there is a problem that it is difficult to accurately detect (qualitative
analysis) or measure (quantitative analysis) such CO gas with either type of CO gas sensor due to
influence of the hydrogen gas rich atmosphere in which interference by hydrogen gas occurs.
In view of the problem mentioned above, it is an object of the present invention to provide a CO
gas sensor which can accurately carry out detection (qualitative analysis) and measurement
(quantitative analysis) of the concentration of CO gas when CO gas is detected or measured in a
gaseous atmosphere containing a relatively large amount of hydrogen gas and carbon dioxide
gas, a fuel cell power generating apparatus equipped with such a CO gas sensor, and a method of
measuring the concentration of CO gas.
7/28/2019 Smoke Detector Using Zigbee
26/82
26
CHAPTER-5
Relay
7/28/2019 Smoke Detector Using Zigbee
27/82
7/28/2019 Smoke Detector Using Zigbee
28/82
28
diode inside the relay case. Alternatively a contact protection network, consisting of a capacitor
and resistor in series, may absorb the surge. If the coil is designed to be energized with AC, a
small copper ring can be crimped to the end of the solenoid. This "shading ring" creates a small
out-of-phase current, which increases the minimum pull on the armature during the AC cycle.[1]
By analogy with the functions of the original electromagnetic device, a solid-state relay is made
with a thyristor or other solid-state switching device. To achieve electrical isolation an
optocouplercan be used which is a light-emitting diode (LED) coupled with a photo transistor.
Types of relay
Latching relay
A latching relay has two relaxed states (bistable). These are also called 'keep' or 'stay' relays.
When the current is switched off, the relay remains in its last state. This is achieved with a
solenoid operating a ratchet and cam mechanism, or by having two opposing coils with an over-
center spring or permanent magnet to hold the armature and contacts in position while the coil is
relaxed, or with a remnant core. In the ratchet and cam example, the first pulse to the coil turns
the relay on and the second pulse turns it off. In the two coil example, a pulse to one coil turns
the relay on and a pulse to the opposite coil turns the relay off. This type of relay has the
advantage that it consumes power only for an instant, while it is being switched, and it retains its
last setting across a power outage. Reed relay
A reed relay has a set of contacts inside a vacuum orinert gas filled glass tube, which protects
the contacts against atmospheric corrosion. The contacts are closed by a magnetic field generated
when current passes through a coil around the glass tube. Reed relays are capable of faster
switching speeds than larger types of relays, but have low switch current and voltage ratings. See
also reed switch.
Mercury-wetted relay
A mercury-wetted reed relay is a form of reed relay in which the contacts are wetted with
mercury. Such relays are used to switch low-voltage signals (one volt or less) because of its low
contact resistance, or for high-speed counting and timing applications where the mercury
eliminates contact bounce. Mercury wetted relays are position-sensitive and must be mounted
http://en.wikipedia.org/wiki/Relay#cite_note-0#cite_note-0http://en.wikipedia.org/wiki/Thyristorhttp://en.wikipedia.org/wiki/Optocouplerhttp://en.wikipedia.org/wiki/Light-emitting_diodehttp://en.wikipedia.org/wiki/Solenoidhttp://en.wikipedia.org/wiki/Reed_relayhttp://en.wikipedia.org/wiki/Vacuumhttp://en.wikipedia.org/wiki/Inert_gashttp://en.wikipedia.org/wiki/Corrosionhttp://en.wikipedia.org/wiki/Coilhttp://en.wikipedia.org/wiki/Reed_switchhttp://en.wikipedia.org/wiki/Mercury_(element)http://en.wikipedia.org/wiki/Mercury_(element)http://en.wikipedia.org/wiki/Reed_switchhttp://en.wikipedia.org/wiki/Coilhttp://en.wikipedia.org/wiki/Corrosionhttp://en.wikipedia.org/wiki/Inert_gashttp://en.wikipedia.org/wiki/Vacuumhttp://en.wikipedia.org/wiki/Reed_relayhttp://en.wikipedia.org/wiki/Solenoidhttp://en.wikipedia.org/wiki/Light-emitting_diodehttp://en.wikipedia.org/wiki/Optocouplerhttp://en.wikipedia.org/wiki/Thyristorhttp://en.wikipedia.org/wiki/Relay#cite_note-0#cite_note-07/28/2019 Smoke Detector Using Zigbee
29/82
29
vertically to work properly. Because of the toxicity and expense of liquid mercury, these relays
are rarely specified for new equipment. See also mercury switch.
Polarized relay
A Polarized Relay placed the armature between the poles of a permanent magnet to increase
sensitivity. Polarized relays were used in middle 20th Century telephone exchanges to detect
faint pulses and correct telegraphic distortion. The poles were on screws, so a technician could
first adjust them for maximum sensitivity and then apply a bias spring to set the critical current
that would operate the relay.
Machine tool relay
A machine tool relay is a type standardized for industrial control of machine tools, transfer
machines, and other sequential control. They are characterized by a large number of contacts
(sometimes extendable in the field) which are easily converted from normally-open to normally-
closed status, easily replaceable coils, and a form factor that allows compactly installing many
relays in a control panel. Although such relays once were the backbone of automation in such
industries as automobile assembly, the programmable logic controller (PLC) mostly displaced
the machine tool relay from sequential control applications.
Contactor relay
A contactor is a very heavy-duty relay used for switching electric motors and lighting loads.
High-current contacts are made with alloys containing silver. The unavoidable arcing causes thecontacts to oxidize and silver oxide is still a good conductor. Such devices are often used for
motor starters. A motor starter is a contactor with overload protection devices attached. The
overload sensing devices are a form of heat operated relay where a coil heats a bi-metal strip, or
where a solder pot melts, releasing a spring to operate auxiliary contacts. These auxiliary
contacts are in series with the coil. If the overload senses excess current in the load, the coil is
de-energized. Contactor relays can be extremely loud to operate, making them unfit for use
where noise is a chief concern.
Solid-state relay
Solid state relay, which has no moving parts 25 amp or 40 amp solid state contactors
A solid state relay (SSR) is a solid state electronic component that provides a similar function to
an electromechanical relay but does not have any moving components, increasing long-term
reliability. With early SSR's, the tradeoff came from the fact that every transistor has a small
http://en.wikipedia.org/wiki/Mercury_switchhttp://en.wikipedia.org/wiki/Crossbar_switchhttp://en.wikipedia.org/wiki/Form_factorhttp://en.wikipedia.org/wiki/Programmable_logic_controllerhttp://en.wikipedia.org/wiki/Contactorhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Silverhttp://en.wikipedia.org/wiki/Solid_state_(electronics)http://en.wikipedia.org/wiki/Solid_state_relayhttp://en.wikipedia.org/wiki/Solid_state_(electronics)http://en.wikipedia.org/wiki/Electromechanicalhttp://en.wikipedia.org/wiki/Electromechanicalhttp://en.wikipedia.org/wiki/Solid_state_(electronics)http://en.wikipedia.org/wiki/Solid_state_relayhttp://en.wikipedia.org/wiki/Solid_state_(electronics)http://en.wikipedia.org/wiki/Silverhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Contactorhttp://en.wikipedia.org/wiki/Programmable_logic_controllerhttp://en.wikipedia.org/wiki/Form_factorhttp://en.wikipedia.org/wiki/Crossbar_switchhttp://en.wikipedia.org/wiki/Mercury_switch7/28/2019 Smoke Detector Using Zigbee
30/82
30
voltage drop across it. This voltage drop limited the amount of current a given SSR could handle.
As transistors improved, higher current SSR's, able to handle 100 to 1,200 amps, have become
commercially available. Compared to electromagnetic relays, they may be falsely triggered by
transients.
Solid state contactor relay
A solid state contactor is a very heavy-duty solid state relay, including the necessary heat sink,
used for switching electric heaters, small electric motors and lighting loads; where frequent
on/off cycles are required. There are no moving parts to wear out and there is no contact bounce
due to vibration. They are activated by AC control signals or DC control signals from
Programmable logic controller (PLCs), PCs, Transistor-transistor logic (TTL) sources, or other
microprocessor controls.
Buchholz relay
A Buchholz relay is a safety device sensing the accumulation of gas in large oil-filled
transformers, which will alarm on slow accumulation of gas or shut down the transformer if gas
is produced rapidly in the transformer oil.
Forced-guided contacts relay
A forced-guided contacts relay has relay contacts that are mechanically linked together, so that
when the relay coil is energized or de-energized, all of the linked contacts move together. If one
set of contacts in the relay becomes immobilized, no other contact of the same relay will be ableto move. The function of forced-guided contacts is to enable the safety circuit to check the status
of the relay. Forced-guided contacts are also known as "positive-guided contacts", "captive
contacts", "locked contacts", or "safety relays".
Overload protection relay
One type ofelectric motoroverload protection relay is operated by a heating element in series
with the electric motor . The heat generated by the motor current operates a bi-metal strip or
melts solder, releasing a spring to operate contacts. Where the overload relay is exposed to the
same environment as the motor, a useful though crude compensation for motor ambient
temperature is provided.
http://en.wikipedia.org/wiki/Ampshttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Programmable_logic_controllerhttp://en.wikipedia.org/wiki/Transistor-transistor_logichttp://en.wikipedia.org/wiki/Buchholz_relayhttp://en.wikipedia.org/wiki/Transformerhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Solderhttp://en.wikipedia.org/wiki/Solderhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Transformerhttp://en.wikipedia.org/wiki/Buchholz_relayhttp://en.wikipedia.org/wiki/Transistor-transistor_logichttp://en.wikipedia.org/wiki/Programmable_logic_controllerhttp://en.wikipedia.org/wiki/Electric_motorhttp://en.wikipedia.org/wiki/Amps7/28/2019 Smoke Detector Using Zigbee
31/82
31
CHAPTER-6DESIGN AND IMPLEMENTATION
LIST OF COMPONENTS
7/28/2019 Smoke Detector Using Zigbee
32/82
32
6.1 DESIGN AND IMPLEMENTATION
.Power supply circuit supplies +5V DC to all the passive components like resistors, capacitors,
IC and Microcontrollers.
BLOCK DIAGRAM
MICRO
CONTROLLER
PORER
SUPPLY
7/28/2019 Smoke Detector Using Zigbee
33/82
7/28/2019 Smoke Detector Using Zigbee
34/82
7/28/2019 Smoke Detector Using Zigbee
35/82
35
(v) Capacitors in Series
Fig 6.7: Capacitors in series
When capacitors are connected in series (figure 5) their combined resistance is less than any of
the individual capacitances. There is a special equation for the combined capacitance of two
capacitors C1 and C2:
C = (C1C2)/(C1+C2)
6.3. RESISTORS
Fig 6.8: Resistors
Type : passive
Electronic symbol : (Europe)
(US)
http://en.wikipedia.org/wiki/Electronic_symbolhttp://en.wikipedia.org/wiki/File:Resistor_symbol_America.svghttp://en.wikipedia.org/wiki/File:Resistor_symbol_Europe.svghttp://en.wikipedia.org/wiki/File:3_Resistors.jpghttp://en.wikipedia.org/wiki/File:Resistor_symbol_America.svghttp://en.wikipedia.org/wiki/File:Resistor_symbol_Europe.svghttp://en.wikipedia.org/wiki/File:3_Resistors.jpghttp://en.wikipedia.org/wiki/File:Resistor_symbol_America.svghttp://en.wikipedia.org/wiki/File:Resistor_symbol_Europe.svghttp://en.wikipedia.org/wiki/File:3_Resistors.jpghttp://en.wikipedia.org/wiki/File:Resistor_symbol_America.svghttp://en.wikipedia.org/wiki/File:Resistor_symbol_Europe.svghttp://en.wikipedia.org/wiki/File:3_Resistors.jpghttp://en.wikipedia.org/wiki/Electronic_symbol7/28/2019 Smoke Detector Using Zigbee
36/82
36
A resistor is a two-terminal electronic component that produces a voltage across its
terminals that is proportional to the electric current through it in accordance with Ohm's law:
V = IR
Resistors are elements of electrical networks and electronic circuits. The primary
characteristics of a resistor are the resistance, the tolerance, maximum working voltage and the
powerrating. Other characteristics include temperature coefficient, noise, and inductance.
http://en.wikipedia.org/wiki/Terminal_%28electronics%29http://en.wikipedia.org/wiki/Electronic_componenthttp://en.wikipedia.org/wiki/Voltagehttp://en.wikipedia.org/wiki/Proportionality_%28mathematics%29#Direct_proportionhttp://en.wikipedia.org/wiki/Electric_currenthttp://en.wikipedia.org/wiki/Ohm%27s_lawhttp://en.wikipedia.org/wiki/Electrical_networkshttp://en.wikipedia.org/wiki/Electrical_resistancehttp://en.wikipedia.org/wiki/Engineering_tolerance#Electrical_component_tolerancehttp://en.wikipedia.org/wiki/Electric_power#In_circuitshttp://en.wikipedia.org/wiki/Temperature_coefficienthttp://en.wikipedia.org/wiki/Electrical_noisehttp://en.wikipedia.org/wiki/Inductancehttp://en.wikipedia.org/wiki/Inductancehttp://en.wikipedia.org/wiki/Electrical_noisehttp://en.wikipedia.org/wiki/Temperature_coefficienthttp://en.wikipedia.org/wiki/Electric_power#In_circuitshttp://en.wikipedia.org/wiki/Engineering_tolerance#Electrical_component_tolerancehttp://en.wikipedia.org/wiki/Electrical_resistancehttp://en.wikipedia.org/wiki/Electrical_networkshttp://en.wikipedia.org/wiki/Ohm%27s_lawhttp://en.wikipedia.org/wiki/Electric_currenthttp://en.wikipedia.org/wiki/Proportionality_%28mathematics%29#Direct_proportionhttp://en.wikipedia.org/wiki/Voltagehttp://en.wikipedia.org/wiki/Electronic_componenthttp://en.wikipedia.org/wiki/Terminal_%28electronics%297/28/2019 Smoke Detector Using Zigbee
37/82
37
CHAPTER-7
LCD
7/28/2019 Smoke Detector Using Zigbee
38/82
38
LCD INTERFACING
Introduction
The most commonly used Character based LCDs are based on Hitachi's
HD44780 controller or other which are compatible with HD44580. In this
tutorial, we will discuss about character based LCDs, their interfacing
with various microcontrollers, various interfaces (8-bit/4-bit),
programming, special stuff and tricks you can do with these simple
looking LCDs which can give a new look to your application.
Pin Description
The most commonly used LCDs found in the market today are 1 Line, 2
Line or 4 Line LCDs which have only 1 controller and support at most of
80 characters, whereas LCDs supporting more than 80 characters make
use of 2 HD44780 controllers.
Most LCDs with 1 controller has 14 Pins and LCDs with 2 controller has
16 Pins (two pins are extra in both for back-light LED connections). Pindescription is shown in the table below.
Pin No. Name Description
Pin no. 1 VSS Power supply (GND)
Pin no. 2 VCC Power supply (+5V)
Pin no. 3 VEE Contrast adjust
Pin no. 4 RS
0 = Instruction input
1 = Data input
Pin no. 5 R/W0 = Write to LCD module
1 = Read from LCD module
Pin no. 6 EN Enable signal
Pin no. 7 D0 Data bus line 0 (LSB)
Pin no. 8 D1 Data bus line 1
7/28/2019 Smoke Detector Using Zigbee
39/82
39
Pin no. 9 D2 Data bus line 2
Pin no. 10 D3 Data bus line 3
Pin no. 11 D4 Data bus line 4
Pin no. 12 D5 Data bus line 5
Pin no. 13 D6 Data bus line 6
Pin no. 14 D7 Data bus line 7 (MSB)
DDRAM - Display Data RAM
Display data RAM (DDRAM) stores display data represented in 8-bit
character codes. Its extended capacity is 80 X 8 bits, or 80 characters.
The area in display data RAM (DDRAM) that is not used for display can
be used as general data RAM. So whatever you send on the DDRAM is
actually displayed on the LCD. For LCDs like 1x16, only 16 characters
are visible, so whatever you write after 16 chars is written in DDRAM but
is not visible to the user.
CGROM - Character Generator ROM
Now you might be thinking that when you send an ASCII value to
DDRAM, how the character is displayed on LCD? So the answer is
CGROM. The character generator ROM generates 5 x 8 dot or 5 x 10 dot
character patterns from 8-bit character codes (see Figure 5 and Figure 6
for more details). It can generate 208 5 x 8 dot character patterns and 32
5 x 10 dot character patterns. User defined character patterns are also
available by mask-programmed ROM.
As you can see in both the code maps, the character code from 0x00 to
0x07 is occupied by the CGRAM characters or the user defined
characters. If user wants to display the fourth custom character then the
code to display it is 0x03 i.e. when user sends 0x03 code to the LCD
http://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.php7/28/2019 Smoke Detector Using Zigbee
40/82
40
DDRAM then the fourth user created character or pattern will be
displayed on the LCD.
CGRAM - Character Generator RAM
As clear from the name, CGRAM area is used to create customcharacters in LCD. In the character generator RAM, the user can rewrite
character patterns by program. For 5 x 8 dots, eight character patterns
can be written, and for 5 x 10 dots, four character patterns can be
written.
BF - Busy Flag
Busy Flag is a status indicator flag for LCD. When we send a command
or data to the LCD for processing, this flag is set (i.e. BF =1) and as soon
as the instruction is executed successfully this flag is cleared (BF = 0).
This is helpful in producing and exact amount of delay for the LCD
processing.
To read Busy Flag, the condition RS = 0 and R/W = 1 must be met and
The MSB of the LCD data bus (D7) act as busy flag. When BF = 1 means
LCD is busy and will not accept next command or data and BF = 0
means LCD is ready for the next command or data to process.
Instruction Register (IR) and Data Register (DR)
There are two 8-bit registers in HD44780 controller Instruction and Data
register. Instruction register corresponds to the register where you sendcommands to LCD e.g. LCD shift command, LCD clear, LCD address etc.
and Data register is used for storing data which is to be displayed on
LCD. When send the enable signal of the LCD is asserted, the data on
the pins is latched in to the data register and data is then moved
http://www.8051projects.net/lcd-interfacing/basics.phphttp://www.8051projects.net/lcd-interfacing/basics.php7/28/2019 Smoke Detector Using Zigbee
41/82
41
automatically to the DDRAM and hence is displayed on the LCD.
Data Register is not only used for sending data to DDRAM but also for
CGRAM, the address where you want to send the data, is decided by the
instruction you send to LCD.
4-bit programming of LCD
In 4-bit mode the data is sent in nibbles, first we send the higher nibble
and then the lower nibble. To enable the 4-bit mode of LCD, we need to
follow special sequence of initialization that tells the LCD controller that
user has selected 4-bit mode of operation. We call this special sequence
as resetting the LCD. Following is the reset sequence of LCD.
Wait for about 20mS
Send the first init value (0x30)
Wait for about 10mS
Send second init value (0x30)
Wait for about 1mS
Send third init value (0x30)
Wait for 1mS
Select bus width (0x30 - for 8-bit and 0x20 for 4-bit)
Wait for 1mS
The busy flag will only be valid after the above reset sequence. Usually
we do not use busy flag in 4-bit mode as we have to write code for
reading two nibbles from the LCD. Instead we simply put a certain
amount of delay usually 300 to 600uS. This delay might vary depending
on the LCD you are using, as you might have a different crystal
7/28/2019 Smoke Detector Using Zigbee
42/82
42
frequency on which LCD controller is running. So it actually depends on
the LCD module you are using.
In 4-bit mode, we only need 6 pins to interface an LCD. D4-D7 are thedata pins connection and Enable and Register select are for LCD control
pins. We are not using Read/Write (RW) Pin of the LCD, as we are only
writing on the LCD so we have made it grounded permanently. If you
want to use it, then you may connect it on your controller but that will
only increase another pin and does not make any big difference.
Potentiometer RV1 is used to control the LCD contrast. The unwanted
data pins of LCD i.e. D0-D3 are connected to ground.
Sending data/command in 4-bit Mode
We will now look into the common steps to send data/command to LCD
when working in 4-bit mode. In 4-bit mode data is sent nibble by nibble,
first we send higher nibble and then lower nibble. This means in both
command and data sending function we need to separate the higher 4-
bits and lower 4-bits.
The common steps are:
Mask lower 4-bits
Send to the LCD port
Send enable signal
Mask higher 4-bits
Send to LCD port
Send enable signal
http://www.8051projects.net/lcd-interfacing/lcd-4-bit.phphttp://www.8051projects.net/lcd-interfacing/lcd-4-bit.php7/28/2019 Smoke Detector Using Zigbee
43/82
43
CHAPTER-8POWER SUPPLY
7/28/2019 Smoke Detector Using Zigbee
44/82
44
POWER SUPPLY
8.1 1N4007:
8.1.1 FEATURES:
Low forward voltage drop
High surge current capability
8.1.2 ABSOLUTE MAXIMUM RATINGS:
Symbol Parameter Value Unit
IO verage Rectified Current 0.375 lead length
@ TA=750C
1.0
If(surge) Peak forward surge current
8.3ms single half-sine-waveSuperimposed on rated load
30
PD Total Device Dissipation
Derate above 250C
2.5
20
W
mW/C
RJA Thermal Resistance, Junction to Ambient 50 C/W
Tstg Storage Temperature Range -55 to +175 C
TJ Operating Junction Temperature -55 to +150 C
7/28/2019 Smoke Detector Using Zigbee
45/82
7/28/2019 Smoke Detector Using Zigbee
46/82
46
8.2 3-TERMINAL 500mA VOLTAGE REGULATOR:(KA7805, KA7812)
8.2.1 FEATURES:
Output current of 500mA
Output Voltages of 5V,12V
Thermal overload protection
Short circuit protection
Output transistor Safe Operating Area Protection
8.2.2 DESCRIPTION:
7/28/2019 Smoke Detector Using Zigbee
47/82
47
The 3-Terminal Regulator is available in TO-220/D-PAK package and with several fixed output
voltages, making them useful in a wide range of applications. Each type employs internal current
limiting, thermal shutdown and safe operating area protection, making it essentially indestructible.
If adequate heat sinking is provided, they can deliver 1A output current. Although it is designed as
a fixed voltage regulator primarily, the device can be used with external components to obtain
adjustable voltages and currents.
8.2.3. INTERNAL BLOCK DIAGRAM:
SERIESPASS
ELEMENT
Current
Generator
SOA
protection
Startingcircuit
Referencevoltage
Error
Amplifier
Thermal
protection
Input Output
Gnd
7/28/2019 Smoke Detector Using Zigbee
48/82
7/28/2019 Smoke Detector Using Zigbee
49/82
49
0=8V to 18V
Dropout voltage VDrop 0=1A,TJ=+25C
Short Circuit Current ISC I=35V,TA=25C 30 M A
Peak current PK J=25C 2
8.2.6 ELECTRICAL CHARACTERISTICS OF 7812 REGULATOR:
Parameter Symbol Conditions Min. Typ. Max Unit
Output voltage V0 J=+25C 11.5 2.0 .5
5mAI01A,
015W,V1=7V to 20V
11.4 2.0 .6
Line Regulation Regline TJ=25C O=14.5V
30V
10.0 40
MV
I=16V
V
.0 120
Load Regulation Regload TJ=25C I0=5mA
1. 5mA
11 240
MV
0=250mA
750mA
0 120
Quiescent Current 0 TJ=+25C .1 .0 mA
Quiescent Current Change IQ I0=5mA to 1A 1 5 mA
I=14.5V to 30V . 5 0
Output voltage drift V0/T I0=5mA mV/C
Output noise voltage VN F=10Hz to 10kHz 6 V/V0
Ripple Rejection RR F=120Hz
V0=15V to 25V
5 71 DB
Dropout voltage VDrop I0=1A,TJ=+25C
Short Circuit Current ISC VI=35V,TA=25C 30 mA
Peak current IPK J=25C 2.2
7/28/2019 Smoke Detector Using Zigbee
50/82
50
8.2.7 TYPICAL PERFORMANCE CHARACTERISTICS:
fig. peak output current
Fig: output voltage
7/28/2019 Smoke Detector Using Zigbee
51/82
51
8.3 B
C 547 TRANSISTOR:
8.3.1 GENERAL DIAGRAM:
Collector
1
Base
2
3
Emitter
7/28/2019 Smoke Detector Using Zigbee
52/82
52
8.3.2 MAXIMUM RATINGS:
Rating Symbol BC547 Unit
Collector-Emitter voltage VCE0 45 Vdc
Collector-Base voltage VCB0 50 Vdc
Emitter-Base voltage VEB0 6.0 Vdc
Collector current continuous Ic 100 MAdc
Total device Dissipation @TA=25C
Derate above 25C
PD 625
50
mW
mW/C
8.3.3 THERMAL CHARACTERISTICS:
Characteristics Symbol Max. Unit
Thermal resistance, junction to ambient R_JA 00 C/W
Thermal resistance, junction to case R_JC 3.3 C/W
8.3.4 ELECTRICAL CHARACTERISTICS:
1. OFF CHARACTERISTICS:
Characteristic Symbol Min. Typ. Max. Unit
Collector-emitter breakdown voltage
IC=1.0mA,IB=0)
V(BR)CE0 45
Collector-base breakdown voltage
dc)
V(BR)CB0 50
Emitter-base breakdown voltage
IE=10A,IC=0)
V(BR)EB0 6.0
Collector cutoff current
(VCE=50V,VBE=0)
(VCE=30V,TA=125C)
ICES 0.2
-
15
4.0
nA
A
7/28/2019 Smoke Detector Using Zigbee
53/82
53
2. ON CHARACTERISTICS:
Characteristic Symbol Min. Typ. Max. Unitcurrent gain
IC=2.0mA,VCE=5.0V)
hFE 10 800
Collector-emitter saturation voltage
IC=10mA,IB=0.5mA)
IC=100mA,IB=5.0mA)
IC=10mA)
VCE(sat)
0.09
0.2
0.3
0.25
0.6
0.6
Base-emitter On voltage
IC=2.0mA,VCE=5.0V)
IC=10mA,VCE=5.0V)
IBE(on)
0.55 0.7
0.77
Base-emitter saturation voltage VBE(sat) 0.7
3. SMALL CHARACTERISTICS:
Characteristic Symbol Min. Typ. Max. Unit
Current gain Band Width Product
IC=10mA,VCE=5.0,f=100Mhz)
fT 150 300 MHz
Output capacitance
(VEB=0.5V,IC=0,f=1.0Mhz)
Cobo - 1. 7 4.5 pF
Input capacitance
(VEB=0.5V,IC=0,f=1.0Mhz)
Cibo 10 pF
Small signal current gain
IC=2.0mA,VCE=5.0V,f=1.0khz)
Hfe 125 900
Noise Figure
(IC=0.2mA,VCE=5.0V,Rs=2K,
F =1.0khz,f=200hz)
NF 2 .0 10 dB
7/28/2019 Smoke Detector Using Zigbee
54/82
54
8.4 POWER SUPPLY
8.4.1 OPERATION:
. The input voltage to the diodes 1 and 2 is supplied from a transformer and is equal to the peak
AC voltage of the secondary winding of the transformer as shown in graph 1.
. The circuit consisting of the combination of the two diodes is called full wave rectifier and the
output of this is graph 2 which contains high ripple.
. These diodes combined with a capacitor are known as full wave rectifier with a capacitor.
. This capacitor is known as filtering capacitor improves the output of the rectifier considerably and
the output of this stage is shown in graph 3.
. The efficiency of this rectifier is 81.2%.
. The resistor is used to limit the voltage and current those are supplied to the regulator in order to
avoid the regulator from getting damaged.
. The diode 3 is used to protect the diodes 1 and 2 from the back current discharged by the
capacitor.
VIN (ac)
VIN (ac)
Vout (dc)1 2 3
Regulator|
|
|
||
||
2|
|
|
||
||
3|
|
|
||
||
4
7/28/2019 Smoke Detector Using Zigbee
55/82
55
. The output at this point is not completely regulated since there is still some amount of ripple
present in the rectified voltage.
. Therefore a regulator is used to ensure low voltage ripple and excellent load and line voltage
regulation.
. The graph 4 gives the output of the regulator and this voltage is 99.9% regulated.
. The resistor after the regulator is used to limit the current supplied to the LED.
.When the voltage supplied is greater than 3.8V, the LED will glow.
. The regulated DC voltage output is taken across the capacitor and is further supplied to other
applications.
8.4.2 OUTPUT AT DIFFERENT STAGES OF THE POWER SUPPLY:
Voltage
T
T
T
T
1
2
3
4
7/28/2019 Smoke Detector Using Zigbee
56/82
56
CHAPTER-9
KEIL VISION3
SOFTWARE
7/28/2019 Smoke Detector Using Zigbee
57/82
57
9. KEIL VISION3 SOFTWARE
9.1 VISION3 OVERVIEW:
The Vision3 IDE is a windows based software development platform that combines a
robust editor, project manager, and integrated make facility. Vision3 integrates all tools
including the C compiler, macro assembler, linker/locator, and HEX file generator. Vision3
helps expedite the development process of our embedded applications by providing the
following:
Full-featured source code editor
Device database for configuring the development tool setting
Project manager for creating and maintaining our projects
Integrated make facility for assembling, compiling, and linking our embedded
applications
Dialogs for all development tool settings
True integrated source level Debugger with high-speed CPU and peripheral simulator
Advanced GDI interface for software debugging in the target hardware and for
connection to Keil ULINK
Flash programming utility for downloading the application program into Flash ROM
Links to development tools manuals, device datasheets and users guides
.In the Build Mode, we maintain the project files and generate the
application. In the Debug Mode, we verify our program either with a powerful CPU and
peripheral simulator or with the Keil ULINK USB-JTAG Adapter (or other AGDI drivers) that
connect the debugger to the target system. The ULINK allows us also to download our
application into Flash ROM of our target system.
7/28/2019 Smoke Detector Using Zigbee
58/82
58
9.2 FEATURES and BENEFITS:
Feature BenefitThe Vision3 Simulator is the only
Debugger that completely simulates all
on-chip peripherals.
Write and test the application code before production
hardware is available. Investigate different hardware
configurations to optimize the hardware design.
Simulation capabilities may be expanded
using the Advanced Simulation Interface
(AGSI).
Sophisticated systems can be accurately simulated
by adding our own peripheral drivers.
The Code Coverage feature of the
Vision3 Simulator provides analysis of
our programs execution.
Safety-critical systems can be thoroughly tested and
validated. Execution analysis reports can be viewed
and printed for certification requirements.
The Vision3 Device Database
automatically configures the
development tools for the target micro
controller.
Mistakes in tool settings are practically eliminated
and tool configuration time is minimized.
The Vision3 IDE integrates additional
third-party tools like VCS, CASE, and
FLASH/Device Programming.
Quickly access development tools and third-party
tools. All configuration details are saved in the
Vision3 project.
Identical Target Debugger and Simulator
User Interface.
Shortens our learning curve.
Vision3 incorporates project manager,
editor, and debugger in a single
environment.
Accelerates application development. While editing,
we may configure debugger features. While
debugging, we may make source code modifications.
7/28/2019 Smoke Detector Using Zigbee
59/82
7/28/2019 Smoke Detector Using Zigbee
60/82
60
The tabs of the Project Workspace give us access to:
Files and Groups of the project.
CPU Registers during debugging.
Tool and project specific on-line Books.
Text Templates for often used text blocks.
Function in the project for quick editor navigation.
The tabs of the Output Window provides: Build messages and fast error access;
Debug Command input/output console; Find in Files results with quick file access.
The Memory Window gives access to the memory areas in display various formats.
The Watch and Call Stack Window allows us to review and modify program variables and
displays the current function call tree.
The Workspace is used for the file editing, disassembly output, and other debug
information.
The Peripheral Dialogs help us to review the status of the on-chip peripherals in the
microcontroller.
9.4 SOFTWARE DEVELOPMENT LIFE CYCLE:
When you use the Keil Vision3, the project development cycle is
roughly the same as it is for any other software development project.
1. Create a project, select the target chip from the device database, and configure the tool
settings.
2. Create source files in C or assembly.
3. Build our application with the project manager.
4. Correct errors in source files.
5. Test the linked application.
7/28/2019 Smoke Detector Using Zigbee
61/82
7/28/2019 Smoke Detector Using Zigbee
62/82
62
files and organize them into a project that defines our target application. Vision3 automatically
compiles, assembles, and links our embedded application and provides a single focal point for
our development efforts.
9.4.2 C COMPILER & MACRO ASSEMBLER:
Source files are created by the Vision3 IDE and are passed to the C or EC++ Compiler
or Macro Assembler. The compiler and assembler process source files and create re-locatable
object files.
9.4.3 LIBRARY MANAGER:
The library manager allows us to create object library from the object files created by the
compiler and assembler. Libraries are specially formatted, ordered program collections of object
modules that may be used by the linker at a later time. When the linker processes a library, only
those object modules in the library that are necessary to create the program are used.
9.4.4 LINKER/LOCATOR:
The Linker/Locator creates an executable program file using the object modules extracted
from libraries and those created by the compiler and assembler. An executable program file (also
called absolute object module) contains no re-locatable code or data. All code and data reside at
fixed memory locations. This executable program file may be used:
To program an Flash ROM or other memory devices,
With the Vision3 Debugger for simulation and target debugging,
With an in-circuit emulator for the program testing.
9.4.5 VISION3 DEBUGGER:
The Vision3 symbolic, source-level debugger is ideally suited for fast, reliable program
debugging. The debugger includes a high-speed simulator that let us simulate a microcontroller
7/28/2019 Smoke Detector Using Zigbee
63/82
63
system including on-chip peripherals and external hardware. The attributes of the chip you use
are automatically configured when we select the device from the Device Database.
The Vision3 Debugger provides several ways for us to test our programs on real target
hardware. Use the Keil ULINK USB-JTAG adapter for Flash downloading and software
test of our program via on-chip debugging system like the Embedded ICE macro cell that
is integrated in many ARM devices.
Use the AGDI interface to attach use the Vision3 Debugger front end with our target
system using other debuggers like Monitor, In-System Debugger, or Emulator.
9.5 USER INTERFACE:
The Vision3 User Interface consists of menus, toolbar buttons, keyboard shortcuts,
dialog boxes, and windows that you use as you interact with and manage the various aspects of
your embedded project.
The menu bar provides menus for editor operations, project maintenance, development
tool option settings, program debugging, external tool control, window selection and
manipulation, and on-line help.
The toolbar buttons allow you to rapidly execute Vision3 commands. A Status Bar
provides editor and debugger information. The various toolbars and the status bar can be
enabled or disabled from the View Menu commands.
Keyboard shortcuts offer quick access to Vision3 commands and may be configured via
the menu command Edit-Configuration-Shortcut key.
The following sections list the Vision3 commands that can be reached by menu
commands, toolbar buttons, and keyboard shortcuts. The Vision3 commands are grouped
mainly based on the appearance in the menu bar:
File Menu and File Commands
Edit Menu and Edit Commands
View Menu
7/28/2019 Smoke Detector Using Zigbee
64/82
64
Project Menu and Project Commands
Debug Menu and Debug Commands
Peripherals Menu
9.5.1. FILE MENU AND COMMANDS:
File Menu Tool bar Short cut Description
New... Ctrl+N Create a new source or text file
Open Ctrl+O Open an existing file
Close Close the active file
Save Ctrl+S Save the active file
Save as... Save and rename the active file
Save All Save all open source and text files including project
and the active file
Device Database Maintain the Vision3 device database
License
Management
Maintain and review the installed software
components
Print Setup... Setup the printer
Print Ctrl+P Print the active file
Print Preview Display pages in print view
1 .. 10 Open the most recent used source or text files
Exit Quit Vision3 and prompt for saving files
7/28/2019 Smoke Detector Using Zigbee
65/82
65
9.5.2 PERIPHERALS MENU:
Menu Item
Reset CPU
Sets CPU to reset state.
Interrupts
Opens dialog for the interrupt controller.
I/O Ports
Opens dialogs for the on-chip I/O Ports.
Serial
Opens dialogs for the on-chip Serial Port.
Timer
Opens dialogs for the on-chip Timers/Counters.
Watchdog
Opens dialogs for the on-chip Watchdog Timer.
A/D Converter
Opens dialogs for the on-chip Analog to Digital Converter.
D/A Converter
Opens dialogs for the on-chip Digital to Analog Converter.
IC Controller
Opens dialogs for the on-chip IC Controller.
CAN Controller
Opens dialogs for the on-chip CAN Controller.
7/28/2019 Smoke Detector Using Zigbee
66/82
66
9.6 CREATING APPLICATIONS:
Create a Project: explains the steps required to setup a simple application and to
generate HEX output.
Project Target and File Groups: shows how to create application variants and
organized the files that belong to a project.
Tips and Tricks: provides information about the advanced features of the
Vision3 Project Manager.
9.6.1 CREATE A PROJECT:
Vision3 includes a project manager which makes it easy to design applications for an
ARM based microcontroller. We need to perform the following steps to create a new project:
Create Project file and Select CPU
Project Workspace-Books
Create New Source Files
Add Source Files to the Project
Create Files Groups
Set tool Options for Target Hardware
Configure the CPU Start-up Code
Build Project and Generate Application Program Code
Create a HEX File for PROM Programming
9.6.2 Description:
Create Project file and Select CPU:
To create a new project file, go to the Vision3 menu and select Project New
Vision Project. The Create New Project dialog asks us for the new project file name. At this
7/28/2019 Smoke Detector Using Zigbee
67/82
67
time navigate to the folder where our new project will reside. It's a good idea to use a separate
folder for each project. Use the icon Create New Folder in this dialog to create a new empty
folder. Select this folder and enter the file name for the new project, i.e. Project1. Vision3
creates a new project file with the name PROJECT1.UV2which contains a default target and file
group name. We can see these names in the Project WorkspaceFiles.
Select Microcontroller from Device Database:
When we create a new project Vision3 asks us to select a CPU for our project. The
Select Device dialog box shows the Vision3 device database. Just select the microcontroller
you use. For the example in this chapter we are using the Philips LPC2106 controller. This
selection sets necessary tool options for the LPC2106 device and simplifies the tool
configuration.
Copy and Add the CPU Start-up Code:
An embedded program requires CPU initialization code that needs to match the
configuration of our hardware design. This Start-up Code depends also on the tool chain that we
are using. Since we might need to modify that file to match our target hardware, the file should
be copied to our project folder.
http://www.keil.com/support/man/docs/uv3/uv3_ca_projtargfilegr.htm7/28/2019 Smoke Detector Using Zigbee
68/82
7/28/2019 Smoke Detector Using Zigbee
69/82
69
Configure Start-up Code:
The CPU Start-up Code (on most ARM targets the file name is Startup.S) may be open
from the Project WorkspaceFiles Tab. Most start-up files have embedded comments for the
Vision3 Configure Wizard which provides menu driven selections.
7/28/2019 Smoke Detector Using Zigbee
70/82
70
The default settings of the Start-up Code give a good starting point on most single chip
applications. However you need to adapt the configuration for your target hardware. CPU/PLL
clock and BUS system is target specific and cannot be automatically configured. Some devices
provide options to enable or disable on-chip components (for example on-chip xdata RAM on
8051 variants).We must ensure that the settings in the start-up file match the other settings in
your project. The button Edit as Text opens the Start-up Code in a standard editor window and
allows us to review the source code of this file.
Build a Project:
Typically, the tool settings under Options Target are all we need to start a new application.
We may translate all source files and link the application by clicking on the Build Target toolbar
button.
7/28/2019 Smoke Detector Using Zigbee
71/82
7/28/2019 Smoke Detector Using Zigbee
72/82
72
We may start our PROM programming utility after the make process when us specify the
program under the option UserRun User Program #1 as explained under Start ExternalTools
9.7 PROJECT TARGETS AND FILE GROUPS:
By using different Project Targets Vision3 lets us create several programs from a
single project. We may need one target for testing and another target for a release version of your
application. Each target allows individual tool settings within the same project file. Files Groups
let us group associated files together in a project. This is useful for grouping files into functional
blocks or for identifying engineers in our software team. We have already used file groups in our
example to separate the CPU related files from other source files. With these techniques it is
easily possible to maintain complex projects with several 100 files in Vision3.
The dialog Project-Components, Environment, Books-Project Components allows us
to create project targets and file groups. We have already used this dialog to add system
configuration files in a file group. An example project structure is shown below.
7/28/2019 Smoke Detector Using Zigbee
73/82
73
The Project Workspaceshows all groups and the related files. Files are built and linked in the
same order as shown in this window. You can move file positions with Drag & Drop . We may
select a target or group name and Clickto rename it. The local menu opens with a right mouse
Click and allows you for each item:
to set tool options
to remove the item
to add files to a group
to open the file.
In the build toolbar you can quickly change the current project target to build.
9.7.1 TIPS AND TRICKS:
The following section discusses advanced techniques we may use with the Vision3 Project
Manager.
7/28/2019 Smoke Detector Using Zigbee
74/82
74
Start External Tools after Build Process shows how to execute programs after a
successful build command which is useful for post-processing as required for symbol
information by some emulators or programmers.
Specify a Separate Folder for Listing and Object Files lets us direct the object and
listing files of your project to specific folders.
Use a CPU that is not in the Vision Device Database explains how to define new
Devices that can be selected from the Device Database.
Create a Library File gives us the tool setup that is required for creating library files.
File Extensions allows us to set the file extension for the various file types of a project.
Import Project Files from Vision Version 1 explains you how to import existing
Vision Version 1 *.PRJ files.
Version and Serial Number Information allows you to view project specific tool
version information.
File and Group Specific Options are set via Options for ... in context menu that opens via a
right mouse click on an item in the Project Workspace.
Options for ... provides the following configuration options:
Properties Dialog allows us to set file and group specific options.
Include Always specific Library Modules specify library modules that should be always
included in a project.
7/28/2019 Smoke Detector Using Zigbee
75/82
7/28/2019 Smoke Detector Using Zigbee
76/82
76
CHAPTER-10
CODE
7/28/2019 Smoke Detector Using Zigbee
77/82
77
CHAPTER-11
TESTING
7/28/2019 Smoke Detector Using Zigbee
78/82
78
TESTING THE CIRCUIT
11.1BASIC TESTS:
It is essential to conduct certain preliminary tests prior to testing the software to prevent the damageof the electronic components.
11.2CHECKING THE POWER SUPPLY:
The power supply circuit is expected to produce a constant dc power supply of 5V (or 12V).The
magnitude of the dc voltage given by the circuit depends upon the voltage regulator used.
To test the circuit, a 9-0-9 step down transformer (12-0-12V) is used. The primary is connected
to 230V AC and the secondary is connected to the full wave rectifier part of the circuit. Upon
switching on of the mains, the LED must glow and the voltage across the output terminals must
show 5V (or 12V).
11.3CHECKING THE ICs:
The pins of various ICs used are to be checked properly for their default status in order to ensure
smooth functioning.
The power supply is connected to the chips and voltages across corresponding pins are
checked using a digital multimeter.By default, the input ports of the microcontroller are configured
to 1 and the output ports are configured to 0.
When the microcontrollers havent been connected, the address and data pins of the
encoder and decoders default to 0.
7/28/2019 Smoke Detector Using Zigbee
79/82
7/28/2019 Smoke Detector Using Zigbee
80/82
80
CONCLUSION
A multi system controller allows several electronic gadgets to be controlled by a
single device. This enables automation in any environment that has several electronic devices.
During the course of our project, we have developed a working model to demonstrate the
functioning of a multi system controller using RF communication. The device developed is simple
and controls three devices i.e. bulbs, fan and a remote controlled car. This device is capable of
controlling devices that run on both ac and/or dc power supply.
12.1 FUTURE SCOPE:
With increased complexity, this device can be successfully used in any environment where
automation is desired.
7/28/2019 Smoke Detector Using Zigbee
81/82
81
APPENDIX
7/28/2019 Smoke Detector Using Zigbee
82/82
APPENDIX
BIBLIOGRAPHY
REFERENCE BOOKS:
8051 MICROCONTROLLERS AND EMBEDDED SYSTEMS- MAZIDI & MAZIDI
ADVANCED MICROPROCESSORS AND PERIPHERALS- RAY AND BHURCHANDI
REFERENCE SITES:
www.keil.com
www.wisegeek/microcontroller.com
www.wikipedia.com
www.mytutorialcafe.com
www.avrfreaks.com
www.softpedia.com
www.rfsolutions.co.uk
www.freewebs.com
www.tpub.co
Top Related