DSK 0-052-02 E (01.03)SMD 1A / SMD 2 / SMD 3 flow meters
Modular design, with gearwheel-type flow indicator andbypass system, for oil circulation lubricating systems
www.vogel-fluidtec.de
� Modular design to adapt the lubricating system to machinesand systems anytime.
� Flow adaption by adjusting the throttle screw. The oil flow iscontinuously adjustable even while the machine or system isrunning.
� The setting range of the SMD 1A flow meter is from 0,05 and0,25 l/min. The setting range of the SMD 2 flow meter is from0.1 and 4.4 l/min when using a fine throttle screw and from 4to 8.0 l/min with a coarse throttle screw. The SMD 3 flowmeter is available with a setting range of 4 to 40 l/min.
� Electric wheel monitoring (NAMUR switch). The combinationof optical and electrical monitoring guarantees the bestpossible flow monitoring.
� User-friendliness thanks to a bypass system. If anyservicing work should become necessary, it can be carriedout without changing the setting of the throttle screw andwithout interrupting the lubricant supply.
� Optimal flushing block for easy service.
Flow meters of the SMD 1A, SMD 2 and SMD 3 series aremainly used in oil circulation lubricating systems for papermachines.
They stand out especially for their reliability, easy maintenanceand flexibility.
3 Throttle screw2 Gearwheel-type flow indicator1 NAMUR switch
4 Bypass valve
AdvantagesApplication
3
2
1
4
SMD 3 SMD 1A/SMD 2
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 2
3 5 1 6 2
4
General
The individual flow meters are designed to divide the oil flow ofthe main line into defined flows or block flows if necessary.
Throttling devices have proved to be reliable and flexibleespecially in papermachines that often have several hundredsof lubricating points. Throttle systems are used whenever minoradjustments and corrections of the lubricant supply must beperformend while the machine is running.
For better serviceability and reduced downtime a bypassfunction was integrated into the SMD1A, SMD 2 and SMD 3flow meters.
This makes it possible to service the flow meters withoutchanging the throttle adjustment and with no impact on the oilflow. The bypass function is part of the SMD 1A, SMD 2 andSMD 3 scope of supply.
Assembly of SMD ... flow meters
SMD 1A/SMD 2
SMD 3
Table of ContentsApplication ........................................................................ 1Advantages ...................................................................... 1General ............................................................................ 2Assembly of SMD ... flow meters .................................... 2Mode of operation of the throttling device ....................... 3Mode of operation of the gearwheel-type flow indicator . 3Bypass valve closed (operating position) ...................... 3Bypass valve open (service position) ............................ 3Electric supply for the gearwheel-type flow indicator ..... 3Characteristics of the SMD 1A flow meter ..................... 4Basic dimensions for the SMD 1A flow meter ................ 4Characteristics of the SMD 2 flow meter ........................ 4Basic dimensions for the SMD 2 flow meter ................... 4Characteristics of the SMD 3 flow meter ........................ 5Basic dimensions for the SMD 3 flow meter ................... 5Examples of SMD 1A / SMD 2 / SMD 3 in a stainlesssteel cabinet ..................................................................... 6Order list .......................................................................... 7Documentation ................................................................. 8
Position Description
1 Housing
2 Plexiglas lid
3 Plastic gear wheels
4 Throttle scrwew
5 NAMUR switch (electr. gear wheel monitoring)
6 Bypass screw
7 Cable duct cover/Plate holder
8 Connection screw for modular design
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 3
Mode of operation of the throttling device
The lubricant coming from the supply line flows from the inlet ofthe throttle housing into the wheel chamber of the gearwheel-type flow indicator and over the gear wheels to the throttle.
The flow is regulated by selecting (fine throttle or coarse throttle)and setting the throttle screw.
After having passed the throttle screw the dosed lubricant flowsto the outlet of the throttle housing.
Mode of operation of the gearwheel-typeflow indicator
The lubricant coming from the supply line flows from the inlet ofthe throttle housing into the wheel chamber of the gearwheel-type flow indicator and over the gear wheels to the throttle.
This flow generates a rotation of the gear wheels in the wheelchamber. A NAMUR switch installed above one of the gearwheels detects the rotation (pulse detetion) of the gear wheels,indicating the flow rate at the same time.
The number of pulses as an equipment of the flow by theNAMUR switch (flow rate) depends on the setting detected ofthe throttle screw and the resulting flow.
inlet
lubricant
outlet
lubricant
NAMUR switch
gear wheels
wheelchamber
throttle screw
SMD1A/SMD 2
Gearwheels
Wheel chamber
Cross section of SMD1A/SMD 2
NAMUR switch
The lubricat flows from the inlet through the wheel chamber ofthe gearwheel-type flow indicator and over the throttle screw tothe outlet.
Bypass valve closed (operating position)
Bypass valve open (service position)
No lubricant passes the wheel chamber and the oil flows acrossthe throttle screw directly to the lube point.
bypass valve closed
Bypass valve open
SMD1A/SMD 2 bypass valve closed
SMD1A/SMD 2 bypass valve open
Electric supply for the gearwheel-typeflow indicator
Connect electrical leads according to the technicalspecifications and local regulations (DIN, VDE).
Connection cable for NAMUR switch
white/power supply +
brown/earth -
white
NAMURRL
OV+ PS
brown
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 4
Characteristics of the SMD 1A flow meter
General
Type ............................................ throttle valve
Installation ................................... position any
Material ....................................... housing aluminium, anodised;
lid 1); plastic gear wheels
Inlets ........................................... G 3/4 2) (1.1/16-12 UN 3))
Outlets ........................................ G 3/8 2) (9/16-18 UNF 3))
Ambient temperature range ....... 0 °C to + 70 °C
Number of outlets per module ... 2
Weight ......................................... 1.57 kg
Options ....................................... Connection block, shut off
block, flushing block
HydraulicsWorking pressure ...................... max 16 bar
Lubricant ..................................... Mineral oils and synthetic oilsOperating viscosity ......................... 50 to 650 mm2/s
Nominal flow per flow meter ... 0.05 to 0,25 l/min
Specific flow ................................ 2.6 ml/pulse
Electrics
Characteristics of the NAMUR inductive proximity switch:
Nominal operating voltage ......... 8.2 V
Operating voltage range ............ 5 to 30 V DC
Attenuated power input .............. < 1 mA
Unattenuated power input .......... > 4 mA
Type of protection ...................... IP65
1) = Plastic, clear
2) = BSPP thread
3) = SAE thread
Basic dimensions for the SMD 1A flow meter
Characteristics of the SMD 2 flow meter
General
Type ............................................ throttle valve
Installation ................................... position any
Material ....................................... housing aluminium, anodised;
lid 1); plastic gear wheels
Inlets ........................................... G 3/4 2) (1.1/16-12 UN 3))
Outlets ........................................ G 3/8 2) (9/16-18 UNF 3))
Ambient temperature range ....... 0 °C to + 70 °C
Number of outlets per module ... 2
Weight ......................................... 1.57 kg
Options ....................................... Connection block, shut off
block, flushing block
HydraulicsWorking pressure ...................... max 16 bar
Lubricant ..................................... Mineral oils and synthetic oilsOperating viscosity ......................... 50 to 650 mm2/s
Nominal flow per assembly group .. max. 65 l/min
Nominal flow per flow meter ... 0.1 to 8 l/min
Throttle screw fine ..................... 0.1 to 4.4 l/min
Throttle screw coarse ................ 4 to 8 l/min
Specific flow ................................ 9.3 ml/pulse
Electrics
Characteristics of the NAMUR inductive proximity switch:
Nominal operating voltage ......... 8.2 V
Operating voltage range ............ 5 to 30 V DC
Attenuated power input .............. < 1 mA
Unattenuated power input .......... > 4 mA
Type of protection ...................... IP65
1) = Plastic, clear
2) = BSPP thread
3) = SAE thread
Basic dimensions for the SMD 2 flow meter
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 5
Characteristics of the SMD 3 flow meter
General
Type ............................................ throttle valve
Installation ................................... position any
Material ....................................... housing aluminium, anodised;
lid 1); plastic gear wheels
Inlets ........................................... G 3/4 2) (1.1/16-12 UN3))
Outlets ........................................ G 3/4 2) (1.1/16-12 UN3))
Ambient temperature range ....... 0 °C to + 70 °C
Number of outlets per module ... 1
Weight ......................................... 4.31 kg
Options ....................................... Connection module, shut off
module, flushing block
HydraulicsWorking pressure ...................... max 16 bar
Lubricant ..................................... Mineral oils and synthetic oilsOperating viscosity ......................... 50 to 650 mm2/s
Nominal flow per flow meter . 4 to 40 l/min
Specific flow ................................ 9.3 ml/pulse
Electrics
Characteristics of the NAMUR inductive proximity switch:
Nominal operating voltage ......... 8.2 V
Operating voltage range ............ 5 to 30 V DC
Attenuated power input .............. < 1 mA
Unattenuated power input .......... > 4 mA
Type of protection ...................... IP65
1) = Plastic, clear
2) = BSPP thread
3) = SAE thread
Basic dimensions for the SMD 3 flow meter
6
114
25 7024
104
G3/
4 (1
,1/1
6-12
UN
)M
8
15
G3/
4 (1
,1/1
6-12
UN
)75
39
35
59
111 15
0
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 6
Connection for 60
0
600
410
40
100
hand-held display
Examples of SMD 1A / SMD 2 / SMD 3 in a stainless steel cabinet
max. 12 lubricating points
max. 24 lubricating points
Standard cabinets are available with 12, 24 and 36 lubricating points at the most. The equipment and arrangement are customized.
max. 36 lubricating points
800
G1/2 800
Connection for hand-held display
~ 120 200
100
610
40
100ca. 120
810
200
40
1.000G1/2
Connection for hand-held display
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 7
D3 D2F
fin
1
7,8
9 fin2 9
MS
coarse
D2Gcoarse
D2F/G
5
6M
coarse 3 4fin
7,8
Order list(Stainless steel cabinet on request)
Order No. Order No.Position Type Designation Symbol Specification Specification
BSPP thread UN/UNF thread
1 SMD 3 Flow meter D3 24-2581-2592 24-2581-2693
2 SMD 1A Flow meter (2 fine throttle screws) D2F 24-2581-2598 24-2581-2630
2 SMD 2 Flow meter (2 fine throttle screws) D2F 24-2581-2586 24-2581-2615
3 SMD 2 Flow meter (2 coarse throttle screws) D2G 24-2581-2587 24-2581-2617
Flow meter (1 fine throttle screw (top)4 SMD 2
and 1 coarse throttle screw (bottom))D2F/G 24-2581-2588 24-2581-2616
5 SMD 1A/SMD2 Complete connection block M 24-1503-2103 24-2581-2104
6 SMD 1A/SMD2 Complete shut off block MS 24-1503-2102 on request
7 Plug screw G3/4 DIN 908 (1.1/16-12 UN) 95-0034-0908
8 Gasket A27 x 32 DIN 7603 Cu 95-2721-760324-1855-2029
9 VARIOLUB type plate 44-1826-2937 44-1826-2937
Replacement parts
SMD 1A Set of replacement parts 24-9909-0184 24-9909-0185
SMD 2 Set of replacement parts 24-9909-0178 24-9909-0180
SMD 3 Set of replacement parts 24-9909-0179 24-9909-0182
SMD 1A / SMD 2 Seal kit 24-0404-2520 24-0404-2522
SMD 3 Seal kit 24-0404-2521 24-0404-2523
SMD 1A / SMD 2 / SMD 3 flow meters DSK 0-052-02 E (01.03) 8
Documentation
Operating manual for setting the bypass function on the SMD 2/SMD 3
flow meters of the VARIOLUB lubricating system DSB 0-052-02
Operating manual for VARIOLUB DSB 6-015-09
Please note:
All VOGEL products must be used correctly. If operatinginstructions are supplied with the products, any additionaldevice-specific instructions and information given in thoseoperating instructions should be applied.
Please note, in particular, that hazardous materials of any type,particularly materials that are classified as hazardous in EUDirective 67/548/EEC, article 2, para. 2, must not be used to fillor be pumped and/or distributed by VOGEL central lubricationsystems and components withoutthe prior written approval ofVOGEL.
No products manufactured by VOGEL are approved for usewith gases, liquefied gases, gases that are released underpressure, vapours and any liquids with a vapour pressure ofmore than 0.5 bar above normal atmospheric pressure(1013 mbar) at the maximum permitted temperature.
We
rese
rve
the
right
to m
ake
amen
dmen
ts.
000
0 0
1/03
VOGEL fluidtec GmbH2. Industriestraße 468766 HockenheimGermanyTel. +49 (0) 62 05 / 27-127Fax +49 (0) 62 05 / [email protected]
Willy Vogel AGMotzener Straße 35/3712277 Berlin, GermanyPF 97 04 44 . 12704 BerlinTel. +49 (0) 30-720 02-0Fax +49 (0) 30-720 [email protected]
VOGEL France SASRue Robert Amy, B.P. 13049404 Saumur cedexFranceTel. +33 (0) 241 404 200Fax +33 (0) 241 404 [email protected]
Top Related