S - S E R I E S OV E RV I E W
7 CHS Controls ABTel +46 42 38 61 00, Fax +46 42 38 61 [email protected] www.chscontrols.se
Pg 2/12
Designed to Railway Standards but suitable for multiple application
S - S e r i e s C o n t a c t o r s & D i s c o n n e c t o r s
2 sub-ranges: – SI: full size contactors, 250-1300 Amps per pole, 1-4 poles – SP: compact low power contactors, 300A per pole, 1-3 poles
S-series contactors and disconnectors are globally the most complete range of devices for AC and DC current switching. Flexibly configurable in thousands of versions, they fit a wide variety of applications and offer highest performances to suit virtually any specification
S-Series benefits: – Most flexible configuration of number and types of poles – Full modularity and easy assembly process made for localization – Wide customizability of actuators, terminals and interface options – High reliability and easy maintainability with direct access to parts
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 3/12
SI units are based on a modular design, with the actuator moving a transversal axle, that pulls all poles simultaneously, flexibly configurable in thousands of versions all based on following principles:
High Performance High making and breaking capacity Fully bidirectional – absence of critical currents Thermal current up to 1300A per pole
Flexible Configuration Variable number of poles Combination of N.O. and N.C. poles Different actuation systems (coil/latch)
Reliability Robust Construction Durability up to 2 million operating cycles
Modular Construction Easy assembly process - made for localization 4 standard modules: Pole/Container/Arc Chute/Actuator 2 customizable modules: Terminals/Fixing Base
Full adaptability Multiple terminal configurations Customizable floor or wall fixing base without orientation (settings) change
Easy maintenance Direct access to all the contactor parts for inspection or replacement Complete spare part offer for maintenance
S I c o n c e p t & v e r s i o n s
Arc chute kit
Main pole
Fixing base
Terminals kit (1/2)
Terminals kit (2/2)
Container
Actuator
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 4/12
SI units can be modularly extended up to 4 poles, mechanically connected. Each pole can be NO or NC
Each pole can carry 4 different types of arc chutes, differentiated by voltage rating (size & shape of arc chute) and material of the arc extinguishing parts (plastic / ceramic). Compared to plastic, ceramic arc chutes offer a higher maximum breaking performance and longer durability
The side magnetic blow out plates are sized according to the type of arc chute selected
The arc chutes can be removed from and plugged back onto the poles without tools for easy tips inspection and replacement
Main Poles are available with Indirect blow out, where the blow out coil is fed only during arcing and contactlessly activated by the arc itself. Fully proven bidirectionality, it avoids critical currents in any current direction.
A r c B l o w O u t S y s t e m s
V o l t a g e d i f f e r e n t i a t i n g A r c C h u t e s
1 - 4 p o l e s u n i t s
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 5/12
The SI line poles are available alternatively as Normally Open or Normally Closed contacts, with the same mechanical movement of the actuating hinge.
Different types of poles can therefore be combined side by side in a single container, creating NO/NC combinations, that can be used as Change Overs contacts, with a Break Before Make contacting sequence.
SI line poles can be activated in 2 different ways:
1. Single Coil, monostable, with electronic drive 2. Double Coil, bistable, with latch, 0W hold-in, coil 1 closes, coil 2 opens, on-load switching
SI poles terminal can be configured in 8 different shapes, allowing vertical plane („wall“) or horizontal plane („floor“) fixing without changing the pole orientation and its dynamic behaviour, i.e. without any setting or hardware difference in the poles.
N o r m a l l y O p e n / N o r m a l l y C l o s e d p o l e s
8 Te r m i n a l C o n f i g u r a t i o n s
3 D i f f e r e n t A c t u a t o r T y p e s
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 6/12
SI contactors cover 3 typical Railway DC or AC voltage systems and different levels of thermal currents up to 1300 Amps per pole
S I o v e r v i e w s u m m a r y
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 7/12
Each SI product has a 15 digits talking Part Number which covers all standard options, for thousands of available combinations
S I P a r t N u m b e r S e l e c t i o n
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
S I 1 A 1 0 0 2 C L A C 0 0 0
1 pole unit 12 poles unit 23 poles unit 3 N No aux ctcts
4 poles unit 4 C 1NO+1NC S L 3NO+3NC S
F 1NO+1NC F M 3NO+3NC F
K 2NO+2NC S P 4NO+4NC S
All Normally Open A J 2NO+2NC F Q 4NO+4NC F
All Normally Closed REqual NO + NC (2&4 poles only) Y
ABCDE
1000V, ceramic arc chute F
2000V, ceramic arc chute
3000V, ceramic arc chute
250 Amp
350 Amp
450 Amp
650 Amp
800 Amp
1000 Amp
1300 Amp
No. of aux contacts (S=screw / F=faston)
Poles configuration
Control voltage Vc (+25%/-30%)
9 Main Digits (Father Part Number) 6 Configuration Digits (Son Part Number)
Number of poles Configuration digits
L L-terminals, bottom fixingThermal current per pole @40°C
24Vdc (16,8 - 30Vdc)
36Vdc (25,2 - 45Vdc)
48Vdc (33,6 - 56Vdc)Arc chute size and type 72Vdc (50,4 - 90Vdc)
110Vdc (77 - 137,5Vdc)11 220Vdc (154 - 275Vdc)
21
31 Terminals configuration
02S Shifted terminals, bottom fixing
0305
M Straight terminals, bottom fixing0708
E Same side terminals, bottom fixing1013
F L-terminals, wall fixing
Z Shifted terminals, wall fixingActuator type
Coil, electronic driven, monostable actuation, contactor functionality, on load switching C I Straight terminals, wall fixing
Close + open coils, bistable actuation, magnetic latch, zero power hold, positive opening, on load switching allowed T B Same side terminal, wall fixing
M
E
S
L
F
Z
I
B
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 8/12
SP units are built for smaller power control with a simpler and more compact design, based on permanent magnet blow out, to fit all those less demanding applications:
S P c o n c e p t & v e r s i o n s
High Performance High making and breaking capacity in compact size Unidirectional DC or AC application – absence of critical currents Thermal current 300A per pole
Flexible Configuration Variable number of poles (1-3) Different types of connections
Reliability Robust Construction Setting-free design for both floor or wall mounting Durability up to 2 million operating cycles
Modular Construction 3 standard modules: Pole/Coil-Base/Arc Chute Customizable fitting of aux contacts Easy assembly process - made for localization
Pole Module Coil and base module
Arc chute module Aux contacts
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 9/12
SP units can be modularly extended up to 3 poles, moved by the same actuator.
Each pole can carry 5 different types of arc chutes, differentiated by voltage rating (size, shape & material of arc chute).
• Plastic arc chutes are for light duty / low voltage / precharge applications • Ceramic arc chutes are for heavy duty / full-power applications
The arc chutes can be removed from and plugged back onto the poles without tools for easy tips inspection.
V o l t a g e d i f f e r e n t i a t i n g A r c C h u t e s
1 - 3 p o l e s u n i t s
900V plastic 900V ceramic 1800V plastic 1800V ceramic 3600V ceramic
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 10/12
SP contactors cover 3 typical Railway DC or AC voltage systems and can be configured as 1-2-3 poles units, totalling 9 main combinations of nominal voltage and number of poles
Additionally, a single Normally Closed pole version is available as 900V version
Similarly to SI, also SP products have a 15 digits talking Part Number which covers all standard options, for hundreds of available combinations:
S P P a r t N u m b e r S e l e c t i o n
S P o v e r v i e w s u m m a r y
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 11/12
All information contained in the present document is subject to change without notice
S I O v e r a l l S i z e s
SI sizes cover the overall dimensions of bodies and arc chutes Terminals and fixing plate may protrude beyond given dimensions, depending on selected versions
H
L W
S P O v e r a l l s i z e s
Terminals and fixing plate protrude beyond given dimensions, depending on selected versions
10 20 30 10 20 30 1p 2p 3p 4pS__02 220 260 300 233 273 313 67 118 169 220S__03 220 260 300 233 273 313 67 118 169 220S__05 284 304 349 266 286 331 75 143 211 279S__07 284 304 349 266 286 331 75 143 211 279S__08 284 304 349 266 286 331 75 143 211 279S__10 284 304 349 266 286 331 95 183 271 359S__13 284 304 349 331 351 371 95 183 271 359
mmWL H
1p 2p 3pSP1x03 170 179SP2x03 220 189SP3103 220 189
70 130 190
mmW
L H
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Pg 12/12
Via E. Fermi 50, 20090 Trezzano sul Naviglio (Milano) – Italy
Phone/Fax +39.02.4969.9540 – email: [email protected] www.telarc.it
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se