OPERATING INSTRUCTIONS
Pull-rope emergency stop switch
Type PRS
7/30/2019 pull-chord manual
2/30
Legal notice
Operating Instructions (Translation of original)
Document no.: 94.064 131.191
Pull-rope emergency stop switch, Type PRS
Equipment item no.: various
Date of issue: 21.11.2008
Update status: Index 0
CE conformity certificate
The device complies with the relevant European and
national regulations.
CE conformity has been certified; the relevant records
are in the hands of the manufacturer.
Protective note (as per DIN ISO 16016:2002-5)
Forwarding and duplicating this document, as well as
using or revealing its contents are prohibited without
written approval. Noncompliance is subject to
compensatory damages. All rights reserved with regard
to patent claims or submission of design or utility patent.
www.kiepe-elektrik.com Tel.: +49 (0) 211 / 74 97 0Fax: +49 (0) 211 / 74 97 420
Vossloh Kiepe GmbH
Kiepe-Platz 1
40599 Dsseldorf
Germany
CONFIDE
NTIAL
7/30/2019 pull-chord manual
3/30
3
Operating Instructions PRS
CONFIDENTIAL
Table of contents
1 For your safety..................................................................................................................5
1.1 Intended use.................................................................................................................................................51.2 Design of warnings .......................................................................................................................................6
2 Transport, storage and disposal .......................................................................................8
2.1 Transport and packaging..............................................................................................................................8
2.2 Storage .........................................................................................................................................................8
2.3 Disposal ........................................................................................................................................................8
3 Description........................................................................................................................93.1 How the emergency stop function works for all types...................................................................................9
4 Technical data ................................................................................................................11
4.1 General technical data................................................................................................................................11
4.3 Dimensions.................................................................................................................................................13
5 Mounting and dismounting..............................................................................................14
5.1 Scope of delivery ........................................................................................................................................14
5.2 Mounting .....................................................................................................................................................14
5.2.1 Important mounting instructions..................................................................................................................14
5.2.2 KIEPE mounting accessories .....................................................................................................................15
5.2.3 Mechanical mounting..................................................................................................................................16
7/30/2019 pull-chord manual
4/30
4
PRS Operating Instructions
CONFIDENTIAL
5.2.4 Electrical connection .................................................................................................................................. 21
5.2.4.1 Preparation work........................................................................................................................................ 21
5.2.4.2 Connecting types PRS 001 and PRS 101.................................................................................................. 22
5.3 Dismounting ............................................................................................................................................... 23
6 Maintenance and repair..................................................................................................25
7 Ordering devices, replacement parts and accessories .................................................. 26
7.1 Ordering devices........................................................................................................................................ 26
7.2 Ordering replacement parts and accessories ............................................................................................ 27
7/30/2019 pull-chord manual
5/30
5
Operating Instructions PRS
1 For your safety
CONFIDENTIAL
1 For your safety
1.1 Intended use
Pull-rope emergency stop switches are used in conveyorsystems for emergency stop of continuous conveyors.
The pull-rope emergency stop switches meet the very
high requirements of industry safety regulations, which
stipulate that emergency stop equipment on conveyor
systems must be used to ensure worker's safety
(VBG 10/BGI 710). The device is intended for use in sta-
tionary installations and in vehicles.
The documentation at hand is to be considered part of
the product and must be retained and be available to therespective owner/user for the entire service life of the
product. The documentation must be passed on to each
subsequent owner of the product.
The manufacturer is not liable for personal injury and
property damage arising from non-intended use of the
device or unauthorized modifications to the device and
its components. Make sure that the intended use is not
impaired in any way even after unexpected outsideinfluence on the device.
Intended use refers specifically to the operation of the
device in accordance with these operating instruc-
tions. Work on this device may only be carried out by
qualified personnel who are familiar with accident
prevention regulations as well as other generally
recognized safety regulations.
By using the equipment as intended, you protect
yourself and prevent damage to the equipment and
its components.
7/30/2019 pull-chord manual
6/30
6
PRS Operating Instructions
1 For your safety
CONFIDENTIAL
1.2 Design of warnings
Risks are classified in accordance with ISO 3864-2 and
ANSI Z535.6 using the keywords
Danger, Warning, and Caution in the case of
bodily injury,
Beware in the case of property damage, and
Note to convey general information.
In this documentation, the Risks and Notes are classified
and presented as follows:
Note!
Note indicates advice on use and other espe-
cially helpful information.
Danger!
indicates the immediate threat of danger. Not avoidingthis danger will result in death or extremely serious in-
jury (crippling).
Warning!
indicates a possibly dangerous situation. Not avoiding
this dangerous situation could result in death or
extremely serious injury (crippling).
!
!
Caution!
indicates a possibly dangerous situation. Failure to avo-
id this dangerous situation can result in light or minor in-juries.
Beware!
indicates a possibly harmful situation. If this harmful
situation is not avoided, the product or something in its
vicinity could be damaged.
!
!
7/30/2019 pull-chord manual
7/30
7
Operating Instructions PRS
1 For your safety
CONFIDENTIAL
Icons
The following icons are used to more clearly define the
sources of danger. The icons can appear in reference to
any level of danger.
Icon Type of danger
Dangers of all types, except those that are
labeled with the following icon
Injuries caused by dangerous voltages and
currents.
Damage caused by electrostaticdischarges (ESD protection)
Tab. 1-1: Icons for general sources of danger
7/30/2019 pull-chord manual
8/30
8
PRS Operating Instructions
2 Transport, storage and disposal
CONFIDENTIAL
2 Transport, storage and disposal
2.1 Transport and packaging
Select suitable packaging when sending the device orcomponents of the device to Vossloh Kiepe GmbH, e.g.
for repairs. In particular, ensure that the components are
kept clean and protected from shock and moisture. This
prevents damage to the components that may occur
during transport, for which the manufacturer accepts no
liability.
2.2 Storage
Avoid major temperature fluctuations, as these can lead
to condensation that can cause damage to the device
and its components.
The approved storage temperature ranges from -25C to
+70C.
2.3 Disposal
Only materials that are not considered hazardous
according to current engineering practice are used for
Vossloh Kiepe GmbH products. Furthermore, we develop
products that can be recycled after intended use. In our
selection of raw materials and components, we favor
reusable materials. This choice of materials used does not
compromise product safety in any way.
Damage caused by storage
Dirt or water getting into the device and exposure to
weather (e.g. buildup of condensation in the device,
sunlight) damage the device and lead to faster deterio-
ration.
Protect the device by storing it in a clean, dry place
under stable ambient conditions. If possible, store the
device in its original packaging.
!
7/30/2019 pull-chord manual
9/30
9
Operating Instructions PRS
3 Description
CONFIDENTIAL
3 Description
Pull-rope emergency stop switches are used in conveyor
systems for emergency stop of continuous conveyors.
The devices are designed for long service lives under se-vere environmental conditions.
3.1 How the emergency stop functionworks for all types
The trigger lever (3) for the PRS pull-rope emergency
stop switch is actuated via a tear rope (15) which is stret-
ched along the conveyor system (see fig. 3-1).
Actuating the trigger lever (3) causes the switch cylinder
to move to the Off position, so that the trigger lever (3)
is decoupled. At this point, no further switching operation
is possible. When inserting a pull-rope emergency stop
Abb. 3-1: Function
Tension spring (16)
Trigger lever (3)Reset lever (4)
Tear rope (15)
Signal lamp (9)
Max. 50 m
Tension spring (16)Tear rope (15)
Max. 50 m
Attachment point for anchor
hooks (20)Attachment point for
anchor hooks (20)
Warning!
The tear rope should be stretched along the conveyor
system so that it is visible along its entire length.
!
http://-/?-http://-/?-7/30/2019 pull-chord manual
10/30
10
PRS Operating Instructions
3 Description
CONFIDENTIAL
switch with signal lamp (9), it displays the emergency
stop status.
The tear rope length (15) may vary according to local
conditions; however, it must not exceed 50 m on either
side. The tension springs (16) at both ends of the tearrope (15) ensure that the tear rope is foolproof, i.e. if the
tear rope (15) is broken, the pull-rope emergency stop
switch is actuated by the tension spring (16).
The conveyor system can only be restarted if the reset le-
ver (4) has been used to unlock the pull-rope emergency
stop switch at the installation site.
Warning!
After actuating and before resetting the pull-rope emer-
gency stop switch, the installation must be checked
along the entire length of the tear rope (15) in order toestablish why the pull-rope emergency stop switch was
actuated.
!
7/30/2019 pull-chord manual
11/30
11
Operating Instructions PRS
4 Technical data
CONFIDENTIAL
4 Technical data
4.1 General technical data
In compliance with the following stan-dards and regulations
EN 60947-5-1, EN 60947-5-5, EN 0418,VDE 0110 degree of pollution: 2 (inside), 4 (outside), VBG 10/BGI 710
Suitable for Controls and installations according to EN 60204
Version Plastic (casing: yellow (RAL 1004), trigger lever: red (RAL 3000) and reset lever: blue
(similar to RAL 5010)
Mounting 2 screws M 6
Permissible ambient temperature -25C +70C
Switching system
PRS 001 2 snap-acting switches with forced opening for emergency stop circuits (orange termi-
nals)
PRS 101 1 snap-acting switch as normally open contact for the signal lamp
Rated insulation voltage Ui AC 230 V
Rated operating voltage Ue AC 230 V
Conventional thermal current Ith 6 A
Breaking capacity
AC -15DC-13
AC 230 V, 1.5 ADC 60 V / 0.5 A
Protection standard
according to DIN VDE 470, part 1 (EN
60529)
IP 67
Mechanical service life 10.000 switching cycles
7/30/2019 pull-chord manual
12/30
12
PRS Operating Instructions
4 Technical data
CONFIDENTIAL
4.2 Technical data PRS 101 with signal lamp
Conductor infeed Threaded hole for 3 x M 25 x 1.5
1x screwed cable gland M 25 x 1.5; sealing area 9 mm to 17 mm
2 x dummy plug M25 x 1.5
Line connection cross-section Max. 2.5 mm2
Rated operating voltage of the signal
lamp
AC 230 V
(at terminals X14 and X15)
7/30/2019 pull-chord manual
13/30
13
Operating Instructions PRS
4 Technical data
CONFIDENTIAL
4.3 Dimensions
Abb. 4-1: Dimensions
95 175
6
162
113,
5
68,
5
80,
5
54
126
7/30/2019 pull-chord manual
14/30
14
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
5 Mounting and dismounting
5.1 Scope of delivery
The pull-rope emergency stop switches are deliveredready to operate. The screws for mechanical fastening
are not included in the scope of delivery. One cable gland
(10) and two dummy plugs (11) are included in the scope
of delivery (see fig. 5-1).
5.2 Mounting
5.2.1 Important mounting instructions
Observe the following notes while mounting to ensure
that the pull-rope emergency stop switches are operated
properly. If conditions should deviate from those indica-
ted, consult Vossloh Kiepe GmbH (see legal notice for
company address).
When mounting, only use KIEPE accessories. This ap-
plies in particular to the cable gland (10) and the dummy
plug (11).
Mount at an ambient temperature of approx + 15C.
The pull-rope emergency stop switch must be moun-
ted in the middle between the attachment points.
Deviation of up to 3 % of the distance between the
Beware!
Use only screwed cable glands and dummy plugs re-
commended by the manufacturer and supplied with thedevice.
!
Abb. 5-1: Scope of delivery
Thread (M 25 x 1.5) for 1 cable
gland (10) and 2 dummy plugs
(11)
Beware!
The device must only be operated when all three holes
are closed with the supplied cable gland (10) and both
dummy plugs (11). Only use the supplied cable gland
(10) and dummy plugs (11), otherwise the seal can no
longer be guaranteed.
!
http://-/?-http://-/?-7/30/2019 pull-chord manual
15/30
15
Operating Instructions PRS
5 Mounting and dismounting
CONFIDENTIAL
pull-rope emergency stop switch and the attachment
point is permitted.
The distance between the attachment points may
not exceed 100 m.
The attachment points for the anchor hooks (20)must be constructed from sturdy mechanical compo-
nents.
The distance between the eyebolts (19) must not
exceed 2.5 m (see figure 5-2, page 16).
5.2.2 KIEPE mounting accessories
Pull-rope emergency stop switches must be fastened
into place on the conveyor structure using KIEPE acces-
sories.
You will require the following accessories to mount the
pull-rope emergency stop switch (see figure 5-4, page
17)):
two M 6 screws (5) for securing the pull-rope emer-
gency stop switch into place (see figure 5-3, page
17)
Cable gland (10), M 25 x 1.5 (see figure 5-8, page
22)
A tear rope (15) made of red, flexible steel wire,
plastic coated, 3 mm
Tension springs (16), 170 x 20 mm
Turnbuckles (17)
Egg-shaped clamps (18)
Eyebolts (19) M 12 x 60
Anchor hooks (20) M 10
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
16/30
16
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
5.2.3 Mechanical mounting
1. Prior to working, switch off the power supply to the
system. Ensure that the conveyor system cannot be
Danger of fatal electric shock
Work on the device may be performed only by a quali-fied electrical technician.
Prior to working, switch off the power supply to the sys-
tem. Ensure that the system cannot be accidentally
switched on. Mask any neighboring components that
may be live to prevent contact.
Abb. 5-2: Mounting on the conveyor structure
Tension spring
(16)
Tension spring
(16)Tear rope (15)
Trigger lever (3) Egg-shaped clamp (18)Reset lever (4)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Egg-shaped clamp (18)
Attachment point for rope loop (21) Attachment point for rope loop (21)
Tear rope (15)
max. 50 m ( 3 %)max. 50 m ( 3 %)
Rope loop (21) Rope loop (21)
Warning!
The tear rope should be stretched along the conveyor
system so that it is visible along its entire length.
Beware!
The pull-rope emergency stop switches may be used in
control circuits only.
!
!
7/30/2019 pull-chord manual
17/30
17
Operating Instructions PRS
5 Mounting and dismounting
CONFIDENTIAL
accidentally switched on. Mask any neighboring
components that may be live to prevent contact.
2. Secure the pull-rope emergency stop switch in the
middle between the attachment points on the con-
veyor structure (see figures 4-1 and 5-2). In doingso, the actuating lever (3) must point towards the
belt. Secure the pull-rope emergency stop switch
with two screws M 6 (5) through the sockets (13)
(see fig. 5-3).3. Place the anchor hooks (20) on the attachment
points (see fig. 5-2).
4. Hook the tension springs (16) onto the anchor hook
(20) (see fig. 5-4).
Abb. 5-3: Mounting the pull-rope emergency stop switch
Reset lever (4)
Socket (13) for
screws M 6 (5)
Socket (13) for
screws M 6 (5)
Belt side
Trigger lever (3)
Beware!
The attachment points for the anchor hooks (20) must
be constructed from sturdy mechanical components,which the anchor hooks (20) cannot break away from
when actuating the tear rope (15).
!
Abb. 5-4: Attaching the tear rope onto the tension spring
Egg-shaped clamp (18)
Allow 450 to 500 mm of the tear
rope (15) for the rope loop (21)
Tear rope (15)
Tension spring
(16)Anchor hooks (20)
max. 400 mm + 170 mm
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
18/30
18
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
5. Thread the end of the tear rope (15) through the eye
of the tension spring (16). Pull the tear rope (15)
about 450 to 500 mm through the eye, so that it can
form a rope loop (21) at that end to complete the
mounting procedure (see fig. 5-4).Note
The rope loops (21) are designed to limit the ac-
tuating travel of the tear rope (15) when actua-
ted and prevents the tension springs (16) from
overextending. The maximum extension of a
tension spring (16) is approximately 400 mm.
6. Secure the tear rope (15) on the tension spring (16)
using an egg-shaped clamp (18) (see fig. 5-4).Fix
the eyebolts (19) to the conveyor structure to guide
the tear rope (15) (see fig. 5-5).
Distance between eyebolts (19): max. 2.5 m7. Put the tear rope (15) through the eyebolts (19) (see
fig. 5-5).
Setting the spring force
Centering the trigger lever (3) makes it resistant to tem-
perature changes. The tension springs (16) compensate
for any extension or contraction of the tear rope (15)
caused by temperature changes (see fig. 5-5).
Abb. 5-5: Mounting on the conveyor structure and setting the spring force
Tension spring
(16)
Tension spring
(16)Tear rope (15)
Trigger lever (3) Egg-shaped clamp (18)Reset lever (4)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Egg-shaped clamp (18)
Attachment point for rope loop (21) Attachment point for rope loop (21)
Tear rope (15)
max. 50 m ( 3 %)max. 50 m ( 3 %)
Rope loop (21) Rope loop (21)
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
19/30
19
Operating Instructions PRS
5 Mounting and dismounting
CONFIDENTIAL
8. Release the tension of the turnbuckle (17) comple-
tely (see fig. 5-6).
9. Put one end of the tear rope (15) through the eye of
the turnbuckle (17) and hook the turnbuckle (17) into
the trigger lever (3) (see fig. 5-6).
10. Tighten the tear rope (15) so that the tension spring
(16) is extended by 35 mm (see fig. 5-5).
11. Attach this end of the tear rope (15) using an egg-
shaped clamp (18) (see fig. 5-6).
12. Remove the turnbuckle (17) again. Unlock the pull-
rope emergency stop switch by using the reset lever
(4) (see fig. 5-5).
13. Repeat steps 5 - 12 for installing the tear rope (15)
on the other side of the pull-rope emergency stop
switch (see fig. 5-5).
14. Now hook both turnbuckles (17) into place and ope-
rate the actuating lever (3) of the pull-rope emer-
gency stop switch (see fig. 5-5).
The trigger lever (3) can now be moved.
15. Place the actuating lever (3) in the middle using theturnbuckles (17) and adjust the tightened tension
springs (16) so that they are 210 mm long (see
fig. 5-5).
Beware!
If the tear rope tears on one side, the pull-rope emer-
gency stop switch must be actuated by the tensionspring on the other side.
Beware!
The tear rope (15) may be maximum 50 meters long in
each direction.
!
!
Abb. 5-6: Mounting the pull-rope emergency stop switch
Reset lever (4)
Trigger lever (3) Turnbuckle (17) Tear rope (15)
Egg-shaped clamp (18)
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
20/30
20
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
Abb. 5-7: Forming the rope loop
16. Form the rope loops (21) on both tension springs
(16) as follows:
a. place the section of tear rope (15) provided for
the rope loop (21) along the tension spring (16)(See figure 5-7, above).
b. Use the end of the rope loop (21) to make a fas-
tening loop that stops about 50 mm from the end
of the tension spring (16) (See figure 5-7,
above).
c. Use an egg-shaped clamp (18) to attach the
rope loop (21) to the anchor hook (20) (See
figure 5-7, below).
Tear rope (15)Tension spring
(16)Anchor hooks (20)
Egg-shaped clamp (18)
Egg-shaped clamp (18)
50 mm
Rope loop (21)
Rope loop (21)
Tear rope (15)
Tension spring
(16)Anchor hooks (20)
Beware!
Ensure that rope loops are formed on both tension
springs.The rope loops are designed to limit the actuating travel
of the tear rope and prevent the tension springs from
overextending (see figure 5-7, page 20). The maximum
extension of a tension spring is approximately 400 mm.
!
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
21/30
21
Operating Instructions PRS
5 Mounting and dismounting
CONFIDENTIAL
5.2.4 Electrical connection 5.2.4.1 Preparation work
1. Prior to working, switch off the power supply to the
system. Ensure that the conveyor system cannot be
accidentally switched on. Mask any neighboring
components that may be live to prevent contact.2. Open the cover (2) of the belt pull-rope emergency
stop switch by unscrewing the two screws (6) (see
fig. 5-8).
3. Turn the cable gland (10) into one of the threaded
holes M 25 x 1.5 of the pull-rope emergency stop
switch.
4. Close the other two holes with the dummy plugs (11)
5. Pull the connection cable through the cable gland
(10).
Danger of fatal electric shock
Work on the device may be performed only by a quali-fied electrical technician.
Prior to working, switch off the power supply to the sys-
tem. Ensure that the system cannot be accidentally
switched on. Mask any neighboring components that
may be live to prevent contact.
Danger!
The penetration of dust and moisture into the pull-rope
emergency stop switch must be prevented at all costs.
As required, remove any dust which has entered the
unit. Seal the cover immediately after making the elec-
trical connection.
Danger!
Only use connection cables with a diameter of between11 mm and 16 mm. The permissible conductor cross-
sections can be found in Chapter 4: Technical data",
page 11.
!
!
Beware!
The device must only be operated when all three holes
are closed with the supplied cable gland (10) and both
dummy plugs (11). Only use the supplied cable gland
(10) and dummy plugs (11), otherwise the seal can no
longer be guaranteed.
!
http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
22/30
22
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
5.2.4.2 Connecting types PRS 001 and PRS 101
1. Connect the connection cable to the connection ter-
minals (8) according to the connection diagram:
PRS 001 without signal lamp (9):
See figure 5-9PRS 101 with signal lamp (9): See figure 5-10
2. Close the cover (2) of the belt pull-rope emergency
stop switch, and tighten both screws again (6) (see
fig. 5-8).
Abb. 5-9: Assignment of the connection terminals of the
PRS 001Abb. 5-8: Pull-rope emergency stop switch connection
Screw M 6 (5)
Screws (6)
Screw M 6 (5)Cover (2)
Thread (M 25 x 1.5) for 1 ca-
ble gland (10) and 2 dummy
plugs (11)
PRS 001 withoutsignal lamp
Auxiliary signal circuit:
connection terminal (8)
X16 X18 (gray)
10 11 12 13 14 15 16 17 18 19
21 22
Thick lines: Circuit for the PRS 001.
Emergency stop circuit:connection terminal (8)
X10 X13 (orange)
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
23/30
23
Operating Instructions PRS
5 Mounting and dismounting
CONFIDENTIAL
Abb. 5-10: Assignment of the connection terminals of the
PRS 101
5.3 Dismounting
1. Prior to working, switch off the power supply to the
system. Ensure that the conveyor system cannot be
accidentally switched on. Mask any neighboring
components that may be live to prevent contact.
Auxiliary signal circuit:
connection terminal (8)
X16 X19, X21 X22 (gray)
Signal lamp (AC 230 V): con-
nection terminals X14, X15
(gray)
Connection terminal (8)
X10 X13 (orange)
10 11 12 13 14 15 16 17 18 19
21 22
Thin lines: additional circuit for the PRS 101.
PRS 101 with signal lamp
Danger of fatal electric shock
Work on the device may be performed only by a quali-fied electrical technician.
Prior to working, switch off the power supply to the sys-
tem. Ensure that the system cannot be accidentally
switched on. Mask any neighboring components that
may be live to prevent contact.
Danger of fatal electric shock
Prior to dismounting, ensure that the conveyor system
is de-energized. Ensure that the unit cannot be acci-
dentally switched on.
Danger of fatal electric shock
Open the pull-rope emergency stop switch only after it
has been de-energized.
7/30/2019 pull-chord manual
24/30
24
PRS Operating Instructions
5 Mounting and dismounting
CONFIDENTIAL
2. Open the cover (2) of the belt pull-rope emergency
stop switch by unscrewing the two screws (6) (see
fig. 5-11).
3. Unscrew the cable gland (10).
4. Disconnect all electrical connections and pull thecables out of the cable gland (10) (see figure 5-9,
page 22).
5. Unscrew both screws M 6 (5), and remove the
device (see fig. 5-11).
Abb. 5-11: Dismounting the pull-rope emergency stop switch
Screw M 6 (5)
Screws (6)
Screw M 6 (5)Cover (2)
Thread (M 25 x 1.5) for 1 ca-
ble gland (10) and 2 dummy
plugs (11)
http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-7/30/2019 pull-chord manual
25/30
25
Operating Instructions PRS
6 Maintenance and repair
CONFIDENTIAL
6 Maintenance and repair
1. Check the pull-rope emergency stop switch and the
tear rope system at regular intervals (approximately
every three months) to ensure that they are in pro-per condition and function smoothly.
Abb. 6-1: Mounting on the conveyor structure and setting the spring force
Tension spring
(16)
Tension spring
(16)Tear rope (15)
Trigger lever (3) Egg-shaped clamp (18)Reset lever (4)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Eyebolts (19)
Distance: max. 2.5 m
Turnbuckle
(17)
Egg-shaped clamp (18)
Attachment point for rope loop (21) Attachment point for rope loop (21)
Tear rope (15)
max. 50 m ( 3 %)max. 50 m ( 3 %)
Rope loop (21)Rope loop (21)
Danger!
A damaged pull-rope emergency stop switch or dama-
ged components (e.g. cable glands, gaskets) are not to
be used.
Damaged pull-rope emergency stop switches must al-
ways be replaced
!
7/30/2019 pull-chord manual
26/30
26
PRS Operating Instructions
7 Ordering devices, replacement parts and accessories
CONFIDENTIAL
7 Ordering devices, replacement parts and accessories
7.1 Ordering devices
Please provide the following data with every order (see
legal notice for company address):
1. Pull-rope emergency stop switch type
(see rating plate on casing cover):
e.g. PRS 001
2. Product number
(see rating plate on casing cover):
e.g. 91.054 033.001
Type of pull-rope emergency stopswitch
Product number
PRS 001 (without signal lamp) 91.054 033.001
PRS 101 (with signal lamp) 91.054 033.101
7/30/2019 pull-chord manual
27/30
27
Operating Instructions PRS
7 Ordering devices, replacement parts and accessories
CONFIDENTIAL
7.2 Ordering replacement parts andaccessories
Please provide the following data with every order (see
legal notice for company address):
1. Pull-rope emergency stop switch type
(see rating plate on casing cover):
e.g. PRS 001
2. Product number
(see rating plate on casing cover):
e.g. 91.054 033.001
3. Order information and order number (see table):
e.g. eye bolts M 12 x 60, 94.045 727.001
Abb. 7-1: Accessories
Tension spring (16) Tension spring (16)Tear rope (15)
Egg-shaped clamp (18)
Eyebolts (19)
Turnbuckle (17)
Eyebolts (19)
Turnbuckle (17)
Egg-shaped clamp (18)
Anchor hooks (20) Anchor hooks (20)
Tear rope (15)
7/30/2019 pull-chord manual
28/30
28
PRS Operating Instructions
7 Ordering devices, replacement parts and accessories
CONFIDENTIAL
Item Order information Order number
15 Tear rope red, flexible steel wire,
plastic coated 3 mm
Roll 50 m
Roll 100 m
Roll 500 m
94.045 731.001
94.045 731.011
94.045 731.021
94.045 731.031
16 Tension spring V2A
170 mm x 20 mm 94.000 026.681
17 Turnbuckle (metal, 1 hook, 1 eye) 215.22.80.02.01
18 Egg-shaped clamp
for tear rope of 3 mm 94.047 869.001
Abb. 7-2: Accessories
Tear rope (15)
Egg-shaped clamp (18)
Turnbuckle (17)19 Eyebolt
M 12 x 60
M 12 x 200
94.045 727.001
94.045 727.002
20 Anchor hook M 10 94.045 728.001
Item Order information Order number
7/30/2019 pull-chord manual
29/30
29
Operating Instructions PRS
CONFIDENTIAL
7/30/2019 pull-chord manual
30/30
www.vossloh-kiepe.com Tel.: +49 (0) 211 / 74 97 0Fax: +49 (0) 211 / 74 97 420
Vossloh Kiepe GmbH
Kiepe-Platz 1
40599 Dsseldorf
Germany
Top Related