Probe12Probe12
Sap Velocity based Sap Velocity based Sap flow loggerSap flow logger&&Irrigation SchedulerIrrigation Scheduler
Probe12 FeatruresProbe12 Featrures
Based on successful Based on successful Flow4 TechnologyFlow4 Technology Combined advantages of Flow4 and Combined advantages of Flow4 and
TDP sensorTDP sensorAdvantages of TDPAdvantages of TDP
–Sap Velocity principleSap Velocity principle–Less maintenanceLess maintenance–Monitor large treesMonitor large trees–Simple sap flow Simple sap flow calculation and analysiscalculation and analysis
Advantages Flow4Advantages Flow4–Integrated data loggerIntegrated data logger
–User friendly softwareUser friendly software
–Real-time monitoring and Real-time monitoring and controlcontrol
–Communication optionsCommunication options
Sensor CapabilitySensor Capability
TDP 10 TDP 10 12 sensors12 sensors TDP 30 TDP 30 12 sensors12 sensors TDP 50 TDP 50 12 sensors12 sensors TDP 80 TDP 80 4 sensors4 sensors TDP 100TDP 100 4 sensors4 sensors
Probe12 System OverviewProbe12 System Overview
Sapflow DataloggerSapflow DataloggerProbe12-DLProbe12-DL
Dedicated DataloggerDedicated Datalogger Up to 12, 8ft CablesUp to 12, 8ft Cables 4, 8ft cables when 4, 8ft cables when
using TDP 80/100using TDP 80/100 AC AdapterAC Adapter Logs moisture, rain Logs moisture, rain
and irrigationand irrigation
Option 1 Option 2
Irrigation Scheduler Probe12-IS
• Measures Water Balance • Dedicated Datalogger• Indexes Sap Flow to crop• Tipping Bucket Raingage• Flow meter • Valve Control• Soil Moisture Monitor
Probe12 - FeaturesProbe12 - Features
Factory assembled for TDP10/30/50/80/100 based pn Factory assembled for TDP10/30/50/80/100 based pn customer requirements.customer requirements.
Easy on-site expansion of channels up to 12 using Easy on-site expansion of channels up to 12 using terminal swapterminal swap
8’ ft TDP cables, 25, 50, 75 ft. extension cables.8’ ft TDP cables, 25, 50, 75 ft. extension cables. Battery statusBattery status Automatic retrieval at 0:00 HrsAutomatic retrieval at 0:00 Hrs Auto-retrieval schedule data retrieval with csv formatAuto-retrieval schedule data retrieval with csv format Real time use plot, Plot controlsReal time use plot, Plot controls Solar calculator for Probe12, RF modemSolar calculator for Probe12, RF modem Nonvolatile RAM – to retain data in the LoggerNonvolatile RAM – to retain data in the Logger
Terminals installed for all available channels
• Terminal adapter for TDP80 and TDP100
• Heater voltage knob
Control PanelControl Panel
Logger -all features of the -DL model and the following:
• Irrigation needed status LED
• Water control 24 VAC relay output to either:
•Irrigate strobe light
•24 V ac/dc valve actuator
• Rain Gage - 25 ft cable
• Choice of auxiliary sensors (1 of below)
• Soil Moisture sensor - ML2 & 25 ft cable
• Solar Radiation - PAR sensor
• Cable connection to irrigation flow meter - Flow meters available separately for 1”,2”, 3”, 6” size pipe.
Probe12-IS SpecificationsProbe12-IS Specifications
Main Logger File Format: csv format (comma separated)
• Date – mm/dd/yyyy format
• Time - HH:MM
• System voltage - Volts
• Averaged - weighted sap flow g/h.
• Rain collected (mm) accumulated
• Water delivered (calibrated flow) – flow meter accumulated
• External input ( calibrated output) - soil moisture, solar radiation.
• TDP sensor data (for each sensor installed)–
• Sensor Status
• TC voltage (mV)
• Sap Flow (g/h)
• 14 days of data logger storage in non-volatile memory with a scanning interval of 1hour
Probe12-DL Data logger FunctionsProbe12-DL Data logger Functions
Probe12-History DataProbe12-History Data
Flow HistoryFlow History
Hourly Flow rate in g/hr Hourly Flow rate in g/hr 200 Hours of hourly sap flow rate 200 Hours of hourly sap flow rate
storagestorage Collect, Save and plot functionsCollect, Save and plot functions
Data FormatData Format
Date Date Hour Hour Hourly rate(g)Hourly rate(g)
Daily Use History
• Daily accumulated irrigation parameters
• Daily water used in mm
• Daily rain in mm
• Daily Irrigation in mm (Flow meter)
• 100 days of daily use storage
• Data Format
Date Use(mm) Rain(mm) Irr(mm)
Graphical User Interface Probe12Graphical User Interface Probe12
Real-time Sapflow plot
TDP Setup
Terminal diagram
Probe data icon
Plant data icon
Click here for chart control dialog box
Probe12 System Setup
SapFlow(g/hr)TDP sensor status
Probe12 system SetupProbe12 system Setup
TDP SetupTDP Setup
Real-time reportReal-time report
• Parameter Control
– Plant Density - Area
– Irrigation efficiency - Evaporation
– Irrigation Interval
– Index measured plants to crop average (LAI or Stem Area Index)
Irrigation System ControlIrrigation System Control
Irrigation StatusIrrigation Status
OutputsCrop Water DeficitAutomated Valve Control or Irrigation required NotificationWater Need in mm
Water need in Kl
Data logger and HistoryData logger and History
Logger Setup: Auto-retrievalLogger Setup: Auto-retrieval
System: SetupSystem: Setup
Message % of Battery remaining Battery VoltageFULL >=100% > 13 V
GOOD 75% – 100% 12 V – 13 V
LOW BATTERY 50% – 75% 11 V – 12 V
CRITICAL 35% – 50% 10 V – 11 V
FAIL SAFE 0% - 35% 7V - 10 V
FAIL SAFE 0% < 7V
Maintenance and Trouble shootingMaintenance and Trouble shooting• Convenient feature for technical support and trouble shooting
Dynamax, IncDynamax, Inc10808 Fallstone Rd.10808 Fallstone Rd.Suite 350Suite 350Houston, TX 77099Houston, TX 77099Phone: 281-564-5100Phone: 281-564-5100Fax: 281-564-5200Fax: 281-564-5200Email: [email protected]: [email protected]