Portable Ultrasonic Flow Meter (F-133P)
Technical Specifications of Main Body Flow Measurement Accuracy better than + 0.5%
Calorimetric Measurement
Accuracy 2%-3%
Working Power Supply built-in Ni-MH rechargeable battery, charging source 220V, which
supplies for up to 24 hours after charging.
Measuring Period: 500ms (2 times per second, and 128 groups of data collected during
each period)
Display 8 digits, 2 lines characters displayed on the same screen.
Thermal Loss Calculation beginning with 0.25K, temperature resolution: 0.01℃
Processing Temperature Range 4℃ ~ 95℃
Ambient Temperature -20℃~60℃
Signal Output isolated RS485
Communication Protocol MODBUS protocol, FUJI extension protocol
Printout Equipped with built-in integrated thermal printer, which can realize
real-time or timed printing.
Data Storage
The optional built-in data storage unit (SD card) can store time,
instantaneous flow, accumulative flow, signal status and etc. The data
can be transferred into the computer (only one from data storage and
printing functions can be selected).
Installation external application installation Self
-
Other Functions diagnosis to indicate whether the current working condition is
normal or not.
Self
Specifications of Clamp-on Sensor
Technical
parameters:
Standard S1
type
Standard M1
type
Standard L1
type
High-
temperature
S1H type
High-
temperature
M1H type
Applicable
pipe diameter
(DN) 15~100 50~700 100~10000 15~100 50~700
Material ABS Special high-temperature
material
Working
frequency IMHZ
Installation
method V (N、
W)method
V、Z
method Z method
V (N、W)method
V、Z method
Calibration Pairing & Calibrating for the complete machine
Magnetism Yes N/A
Applicable
temperature 0~70℃ 0℃~160℃
Protection
grade: IP65
Dimensions 45×30×30 60×45×45 80×70×55 90×85×24 90×82×29
Mass (gram) 75 250 650 94 150
Media type: Water, seawater, sewage, alcohol, various oils and other single, uniform and
stable liquid that can transmit ultrasonic wave
material mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc.
Signal cable Standard configuration: 5mX2, and 10mX2 or 15mX2 are optional.
Medium
turbidity: ≤20000ppm with low bubble content
Applicable
pipes:
Uniform and compact pipes made of carbon steel, stainless steel, cast iron,
copper, PVC, aluminum, glass fiber reinforced plastics, and lining is
permitted.
Pipe lining Epoxy asphalt, rubber,
Top Related