  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIESCONSORTIUM

    B 14.03.97 AS - BUILT

    ISHREVISED AS MARKED20.11.963 SA SH

    ACMSP2 20.3.96 APPROVAL FOR CONSTRUCTION

    APPROVAL BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.95 APPROVAL FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL3.11.95C GRR SS

    SSGRRB 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    LimitedWorley

    ENGINEERS INDIA LIMITEDNEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELDCENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    01101420003173

    Path\File name\Initials:

    FLOW SHEET & INSTRUMENT LEGENDDocument title:

    Page(s)Company's document No.:

    37130110Path\File name\Initials:

    DISTRIBUTION CODE:

    GENERAL ABBREVIATIONSA P

    A/D ANALOG TO DIGITALANALYZER ELEMENTAE

    ARV AIR RELEASE VALVEANALYZER INDICATORAI

    AT ANALYZER TRANSMITTER

    B

    BS & W TRANSMITTERBSWTBSWR BS & W RECORDER

    BS & W MEASURING ELEMENTBSWE

    BE BURNER FLAME DETECTOR ELEMENT

    C

    CVP CHOKE VALVE POSITIVECHOKE VALVE ADJUSTABLECVA

    D

    DT DENSITY TRANSMITTERDENSITY RECORDERDR

    DV DELUGE VALVE

    EMERGENCY SHUT DOWNESD

    E

    F

    FLOW ALARMFAFAH FLOW ALARM HIGH

    FLOW ALARM LOWFAL

    FLOW CONTROL VALVEFVFLOW ELEMENTFE

    FG FLOW GLASSFLOW INDICATOR

    FDI FLOW DIFFERENTIAL INDICATORFLOW INDICATING CONTROLLERFICFLOW INDICATING TRANSMITTERFIT

    FLA FLAME ARRESTORFLOW METERFMFLOW PRESSURE RECORDER (TWO PEN)FPRFLOW-PRESS.-TEMP.FPTRRECORDER (THREE PEN)

    FQFQIFRFFCFRCFSFSHFSL

    FLOW INGRATORFLOW INGRATOR AND INDICATORFLOW RECORDERFLOW RATIO CONTROLLERFLOW RECORDER CONTROLLERFLOW SWITCHFLOW SWITCH HIGHFLOW SWITCH LOW

    FTFFA

    FLOW TRANSMITTERFLAME FAILURE ALARM

    FX FLOW CALCULATION BLOCK

    GAS DETECTORGD

    G

    IH

    HAND INTIATED CONTROL (MANUAL LOADING)HICHCV HAND CONTROL VALVE

    HEAT ACTUATED DEVICEHAD

    HS HAND SELECTOR

    I

    INTERFACE LEVEL ALARM HICHILAH

    FY,TY CURRENT TO PNEUMATIC TRANSDUCERLY,PY

    ILAL INTERFACE LEVEL ALARM LOWILCILCVILGILICILT

    INTERFACE LEVEL CONTROLINTERFACE LEVEL CONTROL VALVEINTERFACE LEVEL GAUGEINTERFACE LEVEL INDICATING CONTROLINTERFACE LEVEL TRANSMITTER

    LEVEL ALARM HIGH LOWLAHLLAHLA

    LAL LEVEL ALARM LOWLCLVLG

    LIC

    LEVEL CONTROLLERLEVEL CONTROL VALVELEVEL GAUGELEVEL INDICATORLEVEL INDICATOR CONTROLLER

    L

    LEVEL ALARM LEVEL ALARM HIGH

    LITLR

    LSLSHLSLLTLSHHLAHH

    LEVEL INDICATOR TRANSMITTERLEVEL RECORDER

    LEVEL SWITCHLEVEL SWITCH HIGHLEVEL SWITCH LOWLEVEL TRANSMITTERLEVEL SWITCH HIGH HIGHLEVEL ALARM HIGH HIGH

    LSLLLALLLAH2

    LEVEL SWITCH LOW LOWLEVEL ALARM LOW LOWSECOND LEVEL ALARM HIGH

    LSH2 SECOND LEVEL SWITCH HIGH

    MOISTURE INDICATORMIMAAMA

    MIA MOISTURE INDICATOR ALARMMLSMOVMT

    MANUAL LOADING SYSTEMMOTOR OPERATED VALVEMOISTURE TRANSMITTER

    M

    MOISTURE ANALYSERMOISTURE ANALYSER ALARM

    MFC MASTER FLOW CONTROLLER

    O

    PRESSURE ALARMPAPAL PRESSURE ALARM LOW

    PRESSURE ALARM HIGHPAH

    PRESSURE ALARM LOW LOWPALL PUSH BUTTONPBPRESSURE CONTROLLERPRESSURE CONTROL VALVEPV

    PCV SELF ACTUATED PRESSURE CONTROL VALVEPRESSURE DIFFERENTIAL ALARMPRESSURE DIFFERENTIAL CONTROLLERPDCPRESSURE DIFFERENTIAL CONTROL VALVEPRESSURE DIFFERENTIAL INDICATORPDIPRESSURE DIFFERENTIAL INDICATING CONTROLLERPDICPRESSURE DIFFERENTIAL SWITCH HIGHPDSHPRESSURE DIFFERENTIAL SWITCH LOW

    PDTPGPIPIC

    PRPRC

    PRESSURE DIFFERENTIAL TRANSMITTERPRESSURE GAUGEPRESSURE INDICATORPRESSURE INDICATING CONTROLLERPNEUMATIC TO CURRENT TRANSDUCERPRESSURE RECORDERPRESSURE RECORDER CONTROLLERPRESSURE SWITCH

    PSH PRESSURE SWITCH HIGHPRESSURE SWITCH LOW LOW

    PSHH PRESSURE SWITCH HIGH HIGH

    PRESSURE ALARM HIGH HIGHPAHH

    PC

    PDA

    PDCV

    PDSL

    P/I

    PS

    PSLL

    PSHLPSLPSVPTPTRPVSVPYPDAHPDALPXPOV

    PRESSURE SWITCH HIGH LOWPRESSURE SWITCH LOWPRESSURE SAFETY VALVEPRESSURE TRANSMITTERPRESSURE/TEMPERATURE RECORDERPRESSURE CUM VACUUM SAFETY VALVEPRESSURE RELAYPRESSURE DIFFERENTIAL ALARM HIGHPRESSURE DIFFERENTIAL ALARM LOWPRESSURE CALCULATION BLOCKPILOT OPERATED VALVE

    PVRVPDIS

    PRESSURE CUM VACUUM RELIEF VALVEPRESSURE DIFFERENTIAL INDICATOR AND SWITCH

    R/S

    RUPTURE DISCRDRO RESTRICTION ORIFICE

    REMOTE OPERATED VALVEROVRTRTUR/ESCSDASGSOVSRSSHSSLSSSVSSVSTSSD

    RESISTANCE TEMPERATURE TRANSMITTERREMOTE TERMINAL UNIT (TELEMETERY SYSTEM)RESISTANCE TO ELECTRICAL TRANSDUCERSPEED CONTROLLERSHUT DOWN ALARMSIGHT GLASSSOLENOIO OPERATED VALVESPEED RECORDERSPEED SWITCH HIGHSPEED SWITCH LOWSUBSURFACE SAFETY VALVESURFACE SAFETY VALVESPEED TRANSMITTERSAFETY SHUTDOWN (PANEL)

    T

    TEMPERATURE ALARMTATAH TEMPERATURE ALARM HIGH

    TEMPERATURE ALARM LOWTALTCTVTETGTRTRCTITICTSTSHTSLTSVTTTW

    TEMPERATURE CONTROLLERTEMPERATURE CONTROL VALVETEMPERATURE ELEMENTTEMPERATURE GAUGETEMPERATURE RECORDERTEMPERATURE RECORDER CONTROLLERTEMPERATURE INDICATORTEMPERATURE INDICATOR CONTROLLERTEMPERATURE SWITCHTEMPERATURE SWITCH HIGHTEMPERATURE SWTICH LOWTHERMAL SWITCH VALVETEMPERATURE TRANSMITTERTHERMOWELL

    TSHHTAHHTSLLTALLTM

    TEMPERATURE SWTICH HIGH HIGHTEMPERATURE ALARM HIGH HIGHTEMPERATURE SWTICH LOW LOWTEMPERATURE ALARM LOW LOWTIMER

    U

    UNIT (COMMOM) ALARMUAUSD UNIT (COMMOM) SHUT DOWN

    UNIT CONTROL PANELUCPUIC UNIT-SURGE CONTROLLER

    VISCOSITY RECORDERVRVSVVM

    VT VISCOSITY TRANSMITTERVXVSHVAH

    VISCOSITY COMPENSATORVIBRATION SWITCH HIGHVIBRATION ALARM HIGH

    V

    VISCOSITY MONITORVACUUM SAFETY VALVE

    VSHH VIBRATION SWITCH HIGH HIGHVAHH VIBRATION ALARM HIGH HIGH

    DEW POINT ELEMENTXDEXA MISC ALARM

    AUTO SELECT RELAYXAS

    BLOW DOWN VALVEXBDVCONVERTERXC CORROSION METERCONTROL RELAYXCR

    XCV MISC CONTROL VALVEDEW POINT ALARM HIGH

    DEW POINT RECORDERXDRDERIVATIVE CONTROLLERDEW POINT INDICATORXDIDEW POINT TRANSMITTERXDTFLOW ADDERXFAFLOW COMPUTER

    XFFAXFSXFTXGD

    XPAXPI

    FLAME FAILURE ALARM FLAME SENSORFLOW TOTALIZERHAZARDOUS GAS DETECTORIGNITION PANELPIG ALARMPIG DETECTOR/INOICATORPIG INDICATOR SWITCH

    XPSU POWER SUPPLY UNITPILOT VALVE

    XRG RAMP GENRATOR

    BEACON ALARMXBA

    XCM

    XDAH

    XDC

    XFC

    XIP

    XPIS

    XPV

    XRRXSXSDXVXSRHXSRLXSHSOVXTCXTP

    XVB

    RATIO RELAYSELECTOR SWITCHSPHERE DETECTORSHUT DOWN VALVESELECTOR ALARM HIGHSELECTOR ALARM LOWLIMIT SWITCH HIGHSOLENOID VALVETEMPERATURE CONVERTORTICKET PRINTER

    VOLUME BOOSTER

    XTXLY

    POSITION TRANSMITTERHIGH LIMITERS

    X/Z

    XLXIZSCZICZSOXIO

    RUNNING LIGHT INDICATORRUNNING INDICATORVALVE POSITION SWITCH CLOSEVALVE POSITION CLOSE INDICATORVALVE POSITION SWITCH OPENVALVE POSITION OPEN INDICATOR

    OTHER ABBREVIATIONS

    AIR TO CLOSEAC AIR TO OPENAOAUTO RESETAR

    BOH

    CCCD

    CN

    BLOW OUT HATCHBASIS SEDIMENT & WATERCORROSION COUPONCONTINUOUS DRAINCLOSE DRAIN HEADER

    CHOKE NIPPLECLEAN OUT

    CP CORROSION PROBECAR SEAL CLOSED

    CSO CAR SEAL OPEN

    CDH

    CO

    CSC

    CTC

    DAIDFBFCFOFLFSDHHHY

    CENTRAL TELEMETRY CONTROL

    DIRECT ACTIONINSIDE DIAMETERFULL BOREFAIL CLOSEDFAIL OPENFAIL LOCKEDFIRE SHUT DOWNHAND HOLEHYDRANT

    LCLO

    LOCK CLOSEDLOCK OPEN

    MCCMOMOLMR

    MF

    MOTOR CONTROL CENTERMANUALLY OPERATEDMAIN OIL LINEMANUAL RESET

    MAINTENANCE FLANGE

    BS&W

    LCPLELODNBD/SNNF

    LOCAL CONTROL PANELLOWER EXPLOSIVE UNITOUTSIDE DIAMETERNOMINAL BOREDOWN STREAMNORMALLY NO FLOW

    KIC TIME SCHEDULE INDICATORCONTROLLER

    NCNORARBRMRS

    SPSTRS/SSSTHTSOUCTYPV/FHELT/T

    NORMALLY CLOSEDNORMALLY OPENREVERSE ACTINGREDUCED BOREREMOTE MANIFOLDREMOTE STATIONSAMPLE POINTSPECIALITY ITEMSTRAINER (PERMANENT)SEAM TO SEAMSELECTOR SWITCHTHIEF HATCHTIGHT SHUTOFFUTILITY CONNECTIONTYPICALVENDOR FURNISHEDHIGHER EXPLOSIVE LIMITTANGENT TO TANGENT

    GCIDCSHPFLPFS/DFMR

    CMRIASMSLLSSGHODD

    FIRE & GAS PANELGAS CORROSION INHIBITORDISTRIBUTED CONTROL SYSTEMHIGH PRESSURE FLARELOW PRESSURE FLARESHUT DOWNFIELD MANUAL RESET

    CONTROL ROOM MANUAL RESETINSTRUMENT AIR SUPPLYMEAN SEA LEVELLOWER SIGNAL SELECTORGAUCING HATCHOPEN DECK DRAIN

    F&G

    HCLTCSTOL

    HYDROCARBONLOW TEMP. CARBON STEELTOP OF LINE

    LINE INDENTIFICATION

    INSULATIONLINE NO. BY SERIESCLASS & SPECIFICATIONSERVICE & DESICNATIONSIZE

    CLASS & SPECIFICATION INDEX

    SPEC. NO.

    ANSIRATING

    SERVICE

    P,DW,BD,DH,C,DF,FG,FL,A1

    B1

    D1

    E1

    XF1

    F1

    A2

    B2

    D2

    E2

    A3

    SV,VG,GI,GU,HY,N,WI,WC,

    P,DW,DH,C,DF,FG,N,CI,FL,SV,BD,VG,GU,HY,N,WI

    P,DW,BD,DH,C,FG,GI,FLSV,VG,CU,HI,N,WI

    P,DW,BD,DH,C,N,T,FLGI,FG,SV,VG,GU,HY,WI

    P,PD,C,N,FL,SV,GI,GU,HY,WI

    P,BD,C,N,FL,SV,GI,GU,HY

    GL,T

    GL,T

    GL,T

    GL,T

    AI,AU,C

    B3A4A5A6

    A8A15B15D15E15F15PE11

    F2

    A1NA1HA10B10

    E10A17E17

    AU

    WPWF,WU,WR,DW,SHEX.

    WF,WU,SWP,SV,CD,GIP,SV,CD,GIP,SV,CD,GIP,SV,CD,GIP,SV,CD,GI,CPL

    CL

    P,SV,CD,G1,FC,BDFLP,SV,CD,FG,BD,LO,CP,SV,FG,BD,CDLO,SO,M,C,WPLO,SO

    PP(LTCS), FL(LTCS)P(LTCS), FL(LTCS)

    1500

    1500

    150

    300

    600

    900

    150150150

    600

    1500900

    1500

    150

    150

    900150900

    150300

    150150300

    900

    150

    300

    150

    300

    600

    900

    LINE LEGEND

    PWRWI

    RAW SEA WATERWATER INJECTION

    PROCESS LIQUIDS & VAPOUR

    DRAINS & RELIEFSBD BLOW DOWNDHDWFLSVVG

    DRAIN, HYDROCARBONDRAIN, WATER ETCFLARESAFETY VALVE DISCHARGEVENT GAS

    STEAM & CONDENSATEHB BOILER FEED WATERS STEAM

    UTILITIES, GENERAL

    AUGI

    AIR, INSTRUMENTAIR, UTILITYGAS, INSTRUMENTGAS, UTILITY

    AB AIR, BREATHING

    AI

    GU

    UTILITY OILS

    LUBE OILSO SEAL OILLO

    CHEMICALS

    C CHEMICAL / CO2GLYCOL

    SH COPPER CHLORINE SOLUTIONGL

    OTHERSPLT

    PIPE LINESTHERMALTURBINE EXHAUST

    PW PROCESS WATEREX

    INSULATION TYPES

    IH INSULATION (HOT)ICISIAITIE

    INSULATION (COLD)INSULATION (SAFETY)INSULATION (ACCOUSTIC)STEAM TRACINGELECTRICAL TRACING

    IF THERMAL FLUID TRACING

    EQUIPMENT PREFIXES

    BLOWERBCOMPRESSORDRYERDEXCHANGER/HEATEREFILTERFGENERATOR

    H

    MM

    MP

    HEATER

    MIXERMOTORFLAME FRONT GENERATORFLARE TIPPUMP

    TANK/COLUMNV VESSEL/CAISSON

    K

    G

    M

    T,TK

    XPKPMCHCMIMWHWMOMGLMWIM

    MISCELLANEOUSPACKAGEPRODUCTION MANIFOLDCHLORINATORCENTRAL MANIFOLDINLET MANIFOLDWELL HEADWATER MAKEROIL MANIFOLDGAS LIFT MANIFOLDWATER INJECTION MANIFOLD

    TGCG

    TURBO GENERATORDIESEL GENERATOR

    CIMCOMDGTAC

    COMPRESSOR INLET MAINFOLDCOMPRESSOR OUTLET MAINFOLDGAS TURBINE DRIVERAIR COOLER

    ADDITIONAL INSTRUMENT ABBREVATIONS, IF REQUIRED

    THE FOLLOWING TABLE IS A GUIDE FOR ADDING ABBREVITIONS

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    M

    N

    O

    P

    Q

    R

    S

    T

    U

    V

    W

    FOURTH POSITIONFIRST POSITION

    ANALYSIS

    BURNER

    CONDUCTIVITY (ELECTRICAL)

    DENSITY OR SPECIFIC GRAVITY

    VOLTAGE (EMF)

    FLOW

    GLAZING (DIMENSIONAL)

    HAND INTIATED

    CURRENT (ELECTRICAL)

    POWER

    TIME

    LEVEL

    MOISTURE OR HUMIDITY

    PRESSURE OR VACUUM

    QUANTITY OR EVENT

    SPEED OR FREQUENCY

    TEMPERATURE

    UNIT

    VIBRATION

    WEIGHT OR FORCE

    UNCLASSIFIED

    POSITION

    X

    Y

    Z

    SECOND POSITION

    CONTROL CONTROLLER

    DIFFERENTIAL

    ELEMENT

    FRACTION (RATIO)

    GLASS

    INDICATOR/INDICATING

    SCAN

    CONTROL STATION

    LIGHT(PLOT)/LEVEL/LIMIT

    ORIFICE RESTRICTION

    POINT (TEST CONNECTION)

    INTEGRATE (TOTALIZE)

    RECORDER

    SWITCH, SAFETY

    TRANSMITTER

    VALVE

    WELL

    UNCLASSIFIED

    RELAY

    DRIVE

    USUAL OR PREFERRED USAGE

    ALARM

    THIRD POSITION

    ALARM

    CONTROL, CONTROLLER, CLOSE

    ELEMENT

    HIGH

    INDICATOR

    CONTROL STATION

    LOW

    MIDDLE

    OPEN

    PANEL

    RECOODER

    SWITCH, SAFETY

    TRABSMITTER

    VALVE

    UNGLASSIFIED

    RELAY

    DRIVE

    CONTROLLER

    HIGH

    INDICATOR

    LOW

    MIDDLE

    RECORDER

    VALVE

    UNIGLASSIFIED

    LINE DESIGNATIONS

    PH LOCJUY

    PH JUY LOC

    FI

    LI

    DEW POINT ALARM LOWXDAL

    S

    12"-P-E1-1001-ISPROCESS LINES

    UTILITY WATER

    WCWF

    CHILLED WATERCOOLING WATERFIRE WATERPOTABLE WATER

    WU UTILITY WATER

    C/W

    WP

    UTILITY GAS & FUELBLANKET GAS

    DF DIESEL FUELBG

    FUEL GASN NITROGENFG

    I

    J

    K

    LL

    141516 13This drawing and the design it covers ate the property of ENGINEERS INDIA LIMITED. They are nerely loaned and on the borrower's express agreem

    ent that they

    will not be reproduced, copied, loaned, exhibited nor used except in the lim

    ited way and private use perm

    itted by any written consent given by tender to borrower.

    K

    J

    I

    H

    G

    F

    E

    D

    C

    B

    16 15

    A

    5 48 7 611 10 913 1214

    12 91011 678 5 4 123

    E

    F

    G

    H

    LRC LEVEL RECORDER CONTROLLER

    SEWERSW

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95 GRR SS

    SSGRR15.10.95 ISSUED FOR CLIENT'S APPROVAL

    C

    B

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    11101420003173

    Path\File name\Initials:

    FLOW SHEET & INSTRUMENT LEGENDDocument title:

    Page(s)Company's document No.:

    37130111Path\File name\Initials:

    DISTRIBUTION CODE:

    LINES

    LINES IDENTIFICATION

    PROCESS/UTILITY LINE

    ELECTRICAL LINE

    PNEUMATIC LINE

    ELEC. TRACED LINE

    CAPILLARY LINEx x x x x

    SKID/VENDOR LIMIT LINE

    CENTER LINE

    HYDRAULIC LINE

    FUTURE

    SOFTWARE SIGNAL

    LINE RATING CHANGE

    (W/PIPING SPEC. DESIGNATION)

    DEVICE IDENTIFICATION

    LOCALLY MOUNTED

    LOCAL, PURGED

    PANEL MOUNTED

    LOCAL, PANEL MOUNTED

    BACK-PANEL MOUNTED

    BACK LOCAL PANEL

    COMPUTER

    COMPUTER LOCAL PANEL

    DCS/DIDC

    FUNCTION BLOCK

    INTERLOCK

    PLC

    RUNNING LIGHT (LOCAL)

    RUNNING LIGHT (PANEL)

    RUNNING LIGHT

    (LOCAL PANEL)

    S

    SOLENOID VALVE (2WAY)

    SOLENOID VALVE (3WAY)

    S

    FOUR WAY VALVE

    QUICK EXHAUST VALVE

    FUSIBLE PLUG

    PIPING SYMBOLS

    GATE VALVE

    GLOBE VALVE

    CHECK VALVE

    BUTTERFLY VALVE

    PLUG VALVE

    BALL VALVE

    NEEDLE VALVE

    SPRING LOADED VALVE

    DIAPHRAGM VALVE

    CONTROL VALVE

    CONTROL VALVE

    WITH HAND WHEEL

    DOWN STREAM

    SELF ACTUATED PCV

    SELF ACTUATED PCV

    UP STREAM

    HAND-OPERATED VALVE

    PISTON OPERATED VALVE

    MOTOR OPERATED VALVE

    M

    SHUT DOWN VALVE

    BALL CONTROL VALVE

    BUTTERFLY CONTROL VALVE

    PILOT-OPERATED VALVE

    SLOPE (DOWN WARD)

    HAMMER BLIND

    SPECTACLE BLIND

    FLANGE

    REDUCER/EXPANDER

    BURIEDB

    ST STEAM TRAP

    UNION

    INSULATION JOINT

    ADAPTOR (TUBING PIPE)

    FLOW ELEMENT ORIFICE

    TURBINE METER8

    POS. DISP. METER

    ROTAMERTER

    SONIC METERS

    ELECTRIC MOTORM

    PITOT TUBE

    VENTURI METER

    DRAIN PLUGGED

    DRAIN FLANGE

    STRAIGHTENING VALVES

    (FLANGE MODEL)

    FILTER

    CAP (THREADED)

    BLIND FLANGE

    CAP (WELDED)

    HOSE CONN.

    OFF/ON SKID OR SHOP FABRICATED

    T-TYPE STRAINER (WITH VALVE)

    Y-TYPE STRAINER (WITH VALVE)

    TS TEMPORARY STRAINER

    BASKET STRAINER

    FLAME ARRESTER

    ANGLE VALVE

    ANGLE BALL VALVE

    ANGLE CHOKE VALVE

    ANGLE CONTROL VALVE

    3-WAY VALVE

    3-WAY CONTROL VALVE

    CONTINUOUS DRAIN

    VANNE CONTROL VALVE

    HAND-OP. VANNE VALVE

    EXPANSION JOINT

    SILENCER

    OPEN DRAIN SYSTEM

    (WITH LIQUID SEAL)

    S SAMPLE POINT

    DIAPHRAGM SEAL

    101

    PSV

    24

    2J3

    INLET SIZE INCHES

    ORIFICE CODE LETTER

    OUTLET SIZE INCHES

    SET PRESSURE kPa(g)

    RUPTURE DISK

    101

    RD

    SCRAPER / SPHERE TEE

    SPECIALITY ITEMSP

    NITROGEN CARTIDGEN2

    FLEXIBLE HOSE

    RAIN CAP

    LO/LC NORMALLY LOCK OPENINTERCHANGEABLE TO LC

    FSD VALVES

    INTERCHANGEABLE TO LO

    NORMALLY LOCK CLOSEDLC/LO

    NORMALLY CLOSEDNC

    NO NORMALLY OPEN

    NORMALLY NO FLOWNNF

    DELUGE NOZZLE

    MAN WAYM

    H HAND HOLE

    MOTOR DRIVE

    FOAM NOZZLE

    M

    RESTRICTION ORIFICE

    9.11 BORE SIZE MM

    NOTES: -GENERAL

    1. HIGH AND LOW PIPING VENTS AND DRAINS NOT SHOWN ON P&IDS SHALL

    BE SHOWN ON PIPING PLANS AND ELEVATION.

    2. ALL SAFETY VALVES DISCHARGE & EQUIPMENT DEPRESSURIZING LINES

    SHALL BE FREE DRAINING TO FLARE HEADER. THEY SHOULD JOIN FLARE

    HEADER FROM TOP WITH AN ANGLE OF 30 TO 45 WITH FLARE HEADER

    AXIES AND HAVE NO POCKETS TO AND INCLUDING HEADERS.

    3. DELETED

    4. DELETED

    5. DELETED

    6. DRAINS OF LEVEL INSTRUMENTS IN HYDROCARBON SERVICE SHALL BE

    TUBED TO CLOSED DRAIN HEADER WITH 12MM SS TUBING.

    7. FOR PUMP HANDLING LIQUID, CASING VENTS, DRAINS AND BASE PLATE DRAINS SHALL BE PIPED WITH VALVE TO NEAREST

    DECK DRAIN FUNNEL.

    8. PROTECTION AGAINST GALVANIC CORROSION TO BE PROVIDED WHEREVER

    REQUIRED BETWEEN DISSIMILAR MATERIALS.

    9. ALL VENT GAS PIPING SHOULD BE FREE DRAINING WITH NO POCKETS.

    10. ALL LIQUID SAMPLES SHALL BE TAKEN FROM CENTER OF THE PIPE.

    11. PIPING VALVES FOR INSTRUMENTS SHOULD BE AS PER DETAILS GIVENT

    BELOW. ALL VALVES SHOULD BE AS PER APPROPRIATE PIPING

    SPECS. DIAPHRAGM SEAL ALSO AS PER SPECS. ALL TAKE OFF

    COONECTIONS SHALL BE SW (SOCKET WELD) UNLESS OTHERWISE SPECIFIED. FOR INST. SUPPLIED VALVES REFER TO INSTRUMENT

    HOOK-UP DETAILS.

    11.1

    PI

    PI

    INST.

    PIPING 3/4" 1"1/2

    PIPING

    INST.

    PI

    (TYPICAL FOR PI, PT, PC, PIC, PSH, PSL, PSHL)TAKE OFF CONNECTIONS-PIPING 3

    4" VESSEL 1.5" FLANGED.

    ALL DIAPHRAM SEAL TYPE INST. TO HAVE 1.5" FLANGED TAPPING.

    11.2

    PDI

    11.3

    PDI

    MANIFOLD (PER SPECS)

    PIP

    ING

    INST.

    TYPICAL FOR PDI, PDT, PDSH, PDSL, PDSHL)TAKE OFF CONNECTION-PIPING: 3

    4" VESSEL 1.5" FLANGED.

    11.4

    TI TI

    PIPING

    INST. 1.5"

    4" MINIMUM

    (TYPICAL FOR TI, TSH, TSL, TG, TT, TC)

    11.5

    LG

    INST.

    PIP

    ING

    LG

    1/2"

    3/4"

    1/2"

    3/4"

    2"

    2"

    3/4"

    3/4"

    LG

    PIP

    ING

    INST.

    STANDP

    IPE

    VESSEL

    (TYPICAL FOR LG, ILG)

    (TYPICAL FOR DISPLACER TYPE LEVEL TRANSMITTERS)(LT, ILT, LEVEL CONTROLLER (FIELD MOUNTED LC, ILC))

    VESSEL

    STANDP

    IPE

    INST.

    PIP

    ING

    LT

    2"

    2"

    2"

    2"

    2"

    1/2"

    2"

    1/2"

    LT

    PIP

    ING

    INST.

    LT

    11.6

    NOTES CONTINUED ......

    11.7

    LSH

    INST.

    PIP

    ING

    LSH

    1/2"

    1"

    1/2"

    1"

    2"

    2"

    STANDP

    IPE

    (TYPICAL FOR EXTERNAL TYPE LSH, ILSH, LSL, ILSL)TAKE OFF CONNECTIONS-PIPING 1" VESSEL 1.5" FLANGED.

    VESSEL

    INST.

    PIP

    ING

    LSH

    1"

    1"

    11.8 DELETED

    FT

    11.9

    FE FT

    1/2"

    1/2"PIPING

    INST.

    MANIFOLD

    (PER SPEC.)

    INST.

    PIPING

    (TYPICAL FOR FT, FR)IMPULSE LINE SLOPE-

    FOR GAS AND VAPOR-TOWARDS FE

    FOR LIQUIDS TOWARDS FT.

    12. SAMPLE CONNECTION SHALL BE AS PER FOLLOWING TYP. DETAIL.

    GAS SAMPLE TO BE SURFACE ONLY UNLESS OTHERWISE SPECIFIED.

    S

    1"1/2"1"x1/2"

    (LIQUID)

    1"x1/2"

    1/2"1"

    SAMPLE

    BOMB

    1/2"

    1"x1/2"

    1"

    A1

    AS PER

    PIPE

    SPEC.

    TO LP FLARE

    COMPANY

    13. DELETED

    14. ALL EQUIPMENTS AND INSTRUMENTS SHALL BE SUITABLE FOR

    CORROSIVE SALT LADEN MARINE ENVIRONMENT WITH 100HUMIDITY

    15. DELETED

    16. DELETED

    17. DELETED

    18. PIPING REQUIRING INSULATION FOR PERSONNEL PROTECTION SHALL BE AS

    PER THE GENERAL STANDARDS.

    21. ALL INJECTION AND TRANSFER PUMPS TO HAVE ADEQUATE SPACE FOR

    MAINTENANCE AND REMOVAL OF SUCTION AND DISCHARGE VALVE. SUCTION/ DISCHARGE LINES TO HAVE FLANGE/UNION CONNECTIONS CLOSE TO PUMP FOR EASY DISASSEMBLY.

    20. DELETED

    19. DELETED

    22. ALL OPEN DECK DRAINS SHALL BE SEAL WELDED.

    24. DELETED

    23. DELETED

    25. DELETED

    26. DELETED

    27. DELETED

    28. DELETED

    29. ALL SAMPLE POINTS SHALL BE ACCESSIBLE AND LOCATED IN HORIZONTAL LINE.

    35. DELETED

    34. DELETED

    33. DELETED

    32. DELETED

    30. DELETED

    31. DELETED

    36. DELETED

    37. DELETED

    38. DELETED

    39. ALL INSTRUMENT NOS. SHALL BE PREFIXED BY UNIT NO. Lo. TG-0101

    SHALL BE READ AS 21-TC-0101 IN UNIT NO. '21'.

    40. THE SOV ASSEMBLY IS AS FOLLOWS: -(APPLICABLE FOR PLATFORM INLET/OUTLET SHUTDOWN ISOLATION VALVES)

    SOV

    FMR

    IAS

    SOV

    FMR

    SOV

    AR

    XV

    ACTUATOR

    A B C

    BYPASS

    PB

    PLC-2

    FROM

    FROM

    PLC-1

    NOTES CONTINUED ......

    PLC-1

    FROM

    FROM

    PLC-2

    UNIT PLC

    FROM

    CBA

    ACTUATOR

    XV

    CMR

    SOV

    FMR

    SOV

    IAS

    FMR

    SOV

    41. THE SOV ASSEMBLY IS AS FOLLOWS: -(APPLICABLE FOR ALL USD ISOLATION VALVES AND FOR HP COMPRESSOR BLOWDOWN VALVES)

    PB

    CLOSE

    CLOSEPB

    PB

    OPEN OPEN

    PB

    42. THE SOV ASSEMBLY IS AS FOLLOWS: -(APPLICABLE FOR GENERAL PURPOSE BLOWDOWN VALVES)

    SOV

    FMR

    IAS

    SOV

    FMR

    XV

    ACTUATOR

    A B

    PLC-2

    FROM

    FROM

    PLC-1

    OPEN

    PBSSD PANEL

    43. ALL PUMPS AND COOLER SHALL HAVE LOCAL START/STOP PUSH BUTTONS EXCEPT FOR POWER TURBINE AND HP COMPRESSOR AUXILIARYS INCLUDING LUBE OIL COOLER AS PER SOLAR'S

    STANDARD PRACTICE.

    44. TYPICAL CHEMICAL INJECTION POINT SHALL BE AS INDICATED BELOW;

    INJECTION CHEMICAL

    2"

    SPOOL

    PIECE

    PROVIDE 20 HOLES OF

    5mm EACH ON THE SIDE

    FACING THE DIRECTION OF

    FLOW ON THE 1" PIPE

    45. FOR LOCATION OF HEAT FIRE AND GAS DETECTORS, REFER TO DRAWINGS NO. 3713-00-16-51-1601 TO 1806

    46. THE FIRST TWO DIGITS OF ALL INSTRUMENTS DENOTE THE LAST TWO DIGITS OF THE

    RELEVANT P&ID NO. FOR MULTIPLE TRAINS, A,B,C.... ARE ADDED AT THE END OF THE INSTRUMENT TAG NO.

    47. ALL ELECTRONIC TRANSMITERS SHALL BE FITTED WITH LOCAL INDICATION.

    48. ALL PIPING LOW POINTS SHALL HAVE DRAIN CONNECTION WITH VALVE. LOCATION

    SHALL BE DECIDED BY PIPING DISCRIPLINE, THESE SHALL BE BACK DRAFTED DURING AS BUILT.

    49. ALL 4" AND LARGER SIZE BALL VALVES IN 900# CLASS AND ABOVE SHALL BE TRUNNION MOUNTED WITH DOUBLE SEAL AND BLEED.

    50. ALL SHUTDOWN VALVE WITH SINGLE SOLENOID VALVES SHALL HAVE A MANUAL 3-WAY

    VALVE IN THE PNEUMATIC LINE TO ENABLE LOCAL CLOSURE OF THE SHUTDOWN VALVE.

    I

    I

    I

    I

    I

    I

    I

    I

    I

    L

    K

    J

    I

    H

    G

    F

    E

    D

    C

    B

    A

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    wil

    l not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    111216 15 5 48 7 610 91314

    12314 13 12 91011 678 5 41516

    I

    J

    K

    L

    E

    F

    G

    H

    101

    RO

    (GAS)

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    10011420123173

    Path\File name\Initials:

    HP GAS FROM RISER PLTF AND HP SEPARATORDocument title:

    Page(s)Company's document No.:

    37131001Path\File name\Initials:

    DISTRIBUTION CODE:

    NOTES

    3713-00-02-41-0110 &

    TAG. NO. SET POINT

    1300 kPa(g)PAHH-0110

    800 kPa(g)PALL-0111

    1200 kPa(g)PAH-0112

    850 kPa(g)PAL-0112

    1. REFER LEGEND P&ID No.

    3713-00-02-41-0111 FOR NOTES.

    2. SYMMETRICAL PIPING REQUIRED AT INLET AND GAS OUTLET

    3. REFER NOTE-40 OF LEGEND P&ID No.

    1300 kPa(g)PAHH-0105/06

    PAH-0103/04

    950 mm FROM BTLLAH-0101/02

    LAL-0101/02 100 mm FROM BTL

    700 mm FROM BTLLAH2-0108/0110 50 mm FROM BTLLALL-0109/0115

    LAHH-0105/0113

    LALL-0106/07

    LAH-0103/04

    LAL-0103/04

    PAL-0103/04

    1200 kPa(g)1060 mm FROM BTL

    50 mm FROM BTL

    600 mm FROM BTL

    200 mm FROM BTL

    850 kPa(g)

    FOR 1-V-211 A/B.

    3713-00-02-41-0111 FOR DETAILS OF SOV ASSEMBLEY.

    3713-00-02-41-0110 &

    3713-00-02-41-0110 &

    3713-00-02-41-0111 FOR DETAILS OF SOV ASSEMBLEY.

    4. REFER NOTE-41 OF LEGEND P&ID No.

    5. REFER NOTE-42 OF LEGEND P&ID No.

    3713-00-02-41-0110 &

    3713-00-02-41-0111 FOR DETAILS OF SOV ASSEMBLEY.

    6. PROVIDE TAPPING FROM TOP OF PIPE AT HIGHEST POINT.

    7. THE ENTIRE PIPING FROM CCP B/L UPTO THE HP COMPRESSORS SHALL HAVE MIN. BENDS AND LENGHT. PIPING GA's AND ISO's

    SHALL BE REVIEWED TO ENSURE THAT TOTAL P IS WITHIN

    REQUIRED LIMITS.

    M M

    1-V-211B

    0113

    LSHH

    0107

    LSLL

    0113

    LAHH

    CLOSE

    XV-0105

    TRIP

    1-K-501

    V/F

    V/F XV-0109CLOSE

    0107

    LALL

    S0109

    SOV

    CMR

    0109

    ZSC

    0109

    ZSO

    0109

    ZIC

    0109

    ZIO

    2"-P-B1-1009

    0102

    LY

    1"

    3/4"

    FC

    2"

    NC

    0102

    LV

    3/4"

    IAS

    I/P

    3/4"

    NC

    2"

    FC

    3/4"

    B1 A1

    2"-P-B1-1024

    0107

    LV

    0107

    LY

    0102

    LICLAH

    LAL

    FROM

    LSLL-0107

    SPL

    IT

    RANGE

    I/P

    0109

    XV

    FC

    0115

    LSLL

    V/F

    V/F0110

    LSH2

    0110

    LAH23"

    0115

    LALLTO CLOSE

    XV-0106

    2"

    3"x2" NC

    NC

    A1 B1DWG NO. 1137

    TO CDH

    DRAIN

    INST.

    SS TUB

    ING

    0117

    LG

    V/F

    0104

    LT

    V/F

    3/4"2"

    FC

    3/4"

    NC

    3"-DH-A1-2217

    3"-DW-B1-2302

    0104

    LV0104

    LY

    1"

    I/P

    0104

    LIC

    INTERFACE

    LAH

    LAL

    2"-P-B1-1010

    0106

    ZSC

    0106

    ZSO

    0106

    ZIO

    0106

    ZIC

    0106

    XV

    SCMR

    IAS

    0106

    SOV

    LSLL-0115

    FROM

    B1A1

    FC

    BLACK COND. TO

    DWG NO. 1012

    CPP-2

    2"-P-A1-1024

    V/F

    0108

    LG

    0102

    LT

    V/F

    3"

    3"

    2"

    0106

    PSHH

    0106

    PAHH

    V/F

    0104

    PT

    0104

    PI

    V/F

    PAL

    CLOSE

    XV-0105

    4"-P-B1-1003

    A1

    B1 2"

    PAHCS0

    4"-P-B1-1020

    3/4"

    B1

    A1CS0

    6"-SV-A1-25020103

    PSV2700

    2H3

    FIRE

    CASE

    4"-P-B1-1021

    CSC

    CS0A1

    B1

    0104

    PSV2700

    2H3

    CASE

    FIRE

    6"-SV-A1-2504

    3/4"

    14"x20"

    14"x20"

    DWG NO

    . 1135

    20"-P-B1-1006

    HP FLARE

    6"-

    FL-A1-2403

    OILY WATER TO 1-V-451

    DWG NO. 11242"-P-A1-1011

    0105

    XV

    0105

    SOV

    IAS

    NOTE-3S

    20"-P-B1-1004

    0102

    PI

    0102

    TI

    FROM ESD

    LSHH-0113

    PSHH-0106

    0105

    ZSO

    0105

    ZSC

    0105

    ZIO

    0105

    ZIC

    CSC 1"

    FC

    FC

    1"CSC

    0104

    ZIC

    0104

    ZIO

    0104

    ZSC

    0104

    ZSO

    PSHH-0105

    LSHH-0105

    FROM ESD

    0101

    TI

    0101

    PI

    20"-P-B1-1001

    S

    NOTE-3

    IAS

    0104

    SOV

    0104

    XV

    6"-

    FL-A1-2402

    HP FLARE

    20"-P-B1-1005

    DWG NO

    . 1135

    14"x20"

    14"x20"

    3/4"

    6"-SV-A1-2503

    FIRE

    CASE

    2700

    2H3

    0102

    PSV

    B1

    A1CS0

    CSC

    4"-P-B1-1019

    CASE

    FIRE 2700

    2H3

    0101

    PSV 6"-SV-A1-2501

    CS0A1

    B1

    3/4"

    4"-P-B1-1018

    CS0PAH

    2"B1

    A1

    4"-P-B1-1002

    XV-0104

    CLOSE

    PAL

    V/F

    0103

    PI

    0103

    PT

    V/F

    0105

    PAHH

    0105

    PSHH

    2"

    3"

    3"

    V/F

    0101

    LT

    0107

    LG

    V/F

    FCA1 B1

    FROM

    LSLL-0109

    0107

    SOV

    CMR S

    0107

    XV

    0107

    ZIC

    0107

    ZIO

    0107

    ZSO

    0107

    ZSC

    2"-P-B1-1011

    LAL

    LAH

    INTERFACE

    0103

    LIC

    I/P

    1"

    0103

    LY

    0103

    LV

    3"-DH-A1-2216

    NC

    3/4"FC

    2"3/4"

    V/F

    0103

    LT

    V/F

    0111

    LGSS TUB

    ING

    INST.

    DRAIN

    TO CDH

    DWG NO. 1137

    B1A1

    NC

    NC3"x2"

    2"

    XV-0107

    TO CLOSE

    0109

    LALL

    3"

    0108

    LAH2

    0108

    LSH2

    V/F

    V/F

    0109

    LSLL

    FC

    0108

    XV

    2

    I/P

    RANGE

    SPL

    IT

    LSLL-0106

    FROM

    LAL

    LAH

    0101

    LIC

    0106

    LY

    0106

    LV

    2"-P-B1-1022

    A1B1

    3/4"

    FC

    2"

    NC

    3/4"

    I/P

    IAS

    3/4"

    0101

    LV

    NC

    2"

    FC

    3/4"

    1"

    0101

    LY

    2"-P-B1-1008

    0108

    ZIO

    0108

    ZIC

    0108

    ZSO

    0108

    ZSC

    CMR0108

    SOV

    S

    0106

    LALL

    CLOSE

    XV-0108V/F

    V/F

    1-K-501

    TRIP

    XV-0104

    CLOSE

    0105

    LAHH

    0106

    LSLL

    0105

    LSHH

    1-V-211AMM

    3"

    3"

    3"

    3"

    3"-DW-B1-2301

    3"

    3"

    0112

    PT

    0112

    PI

    PAH

    PAL

    FCA1B1

    SNOTE-40102

    SOV

    ESD,UCP OF 1-K-251

    0102

    XV 0102

    ZSC

    IAS

    0102

    ZIC

    0102

    ZSO

    0102

    ZIO

    (1-K-251)UCP

    UCP

    (1-K-251)

    ITEM NO. :

    ITEM NAME :

    SIZE :

    DESIGN PRESS. :

    DESIGN TEMP. :

    LINING :

    180C

    2700 kPa (g)1800 mm (ID) x 7200 mm (T/T)

    INLET SEPARATOR

    1-V-211A/B

    BOOT DIA. = 750 mm (ID)HEIGHT = 750 mm (T/T)EPOXY LINING - FOR BOOT ONLY

    DWG NO. 1007

    LP GAS FROM 1-K-252

    6"-P-A1-1059-ISNO POCKETS

    0103

    ZIO

    0103

    ZSO

    0103

    ZIC

    IAS

    0103

    ZSC

    0103

    XBDV

    FROM

    0103

    SOV

    S

    FO

    NOTE-5

    ESD

    CSO

    2"

    0103

    RO

    2"-FL-A1-2401

    CSO

    9.16

    DWG NO

    . 1135

    HP FLARE

    30"x20"

    30"x20"

    NOTE-2 NOTE-6

    30"-P-B1-1007

    HP FLARE

    DWG NO

    . 1135

    31.18

    CSO 3"-FL-A1-2405

    0101

    RO

    CSO

    ESD

    NOTE-5

    FO

    S0110

    SOV

    0110

    XBDV

    0110

    ZSC

    IAS

    0110

    ZIC

    0110

    ZSO

    0110

    ZIO

    2"x3"B1 A1

    SUCTION HEADER

    DWG NO. 1002

    TO HP COMPRESSOR

    START-UP

    DWG NO. 1131

    FUEL GAS TO 1-K-501

    NOTE-6

    4"-FG-B1-6301-IE

    TO 1-V-254

    DWG NO. 1006

    LP COMPRESSOR

    SUCTION SCRUBBER

    4"-P-B1-1015

    2"x3"

    2"x3"

    DWG NO. 1007

    TO 1-T-231

    3"-P-B1-1008

    0103

    TI

    0110

    PSHH

    0110

    PAHH

    CLOSE SIGNAL TO

    RISER PLTF AND

    CAUSE PSD

    0111

    PALL

    0111

    PSLL

    CAUSE PSD

    RISER PLTF AND

    CLOSE SIGNAL TO

    0109

    TI

    0109

    TT

    FROM RISER PLTF

    DWG NO. 1133

    HP GAS

    NOTE-2

    30"-P-B1-1001

    NOTE-7

    B1

    A1

    LOW

    POINT

    30"x20"

    30"x20"

    DWG NO

    . 1137

    TO CDH

    1.5

    "-DH-A1-2246

    3/4"

    3/4"

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    I

    II

    I

    IAS

    S

    S

    16 15 11 10 913 1214 5 48 7 6

    L

    K

    J

    I

    H

    G

    F

    E

    D

    C

    B

    A

    This draw

    ing

    and

    the

    design

    it co

    vers are

    the

    prop

    erty of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are

    nere

    ly

    loan

    ed and

    on the

    borrow

    er's expres

    s ag

    reem

    ent

    that they

    will not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    limited way and priva

    te use perm

    itted by any written consent g

    iven by

    tender

    to the borrower.

    14 13 121516 11 910 678 5 4 123

    I

    J

    K

    L

    E

    F

    G

    H

    2

    2"

    TU NGOC HAISticky NoteMarked set by TU NGOC HAI1-V-211AOperating Pressure = 9 atShell Thick = 28mmLength = 7200mmInside Diameter = 1800mm2"-P-B1-1011Outside Diameter = 60.3mmthick = 5.5mm3"-DH-A1-2216Outside Diameter = 88.9mmthick = 7.6mm3"-DW-B1-2301Outside Diameter = 88.9mmthick = 7.6mm
  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    20011420523173

    Path\File name\Initials:

    HP COMPRESSOR SUCTION MANIFOLDDocument title:

    Page(s)Company's document No.:

    37131002Path\File name\Initials:

    DISTRIBUTION CODE:

    1. DELETED

    3713-00-02-41-0110 &

    3. REFER LEGEND P&ID No.

    3713-00-02-41-0111 FOR NOTES.

    5. DELETED

    DWG NO. 1303

    TO 1-V-251D

    DWG NO. 1403

    FROM 1-V-211A/B

    DWG NO. 1001

    DWG NO

    . 1135

    LP FLARE

    S

    0202E

    ZIC

    0202E

    SOV

    IAS

    0202E

    XV

    0202E

    ZSC

    0202E

    ZSO

    0202E

    ZIO

    B1D1

    FC

    16"-P-B1-1017E

    S

    0201E

    ZIC

    0201E

    SOV

    0201E

    XV

    0201E

    ZSC

    0201E

    ZSO

    0201E

    ZIO

    B1D1

    FC

    S

    0202D

    ZIC

    0202D

    SOV

    0202D

    XV

    0202D

    ZSC

    0202D

    ZSO

    0202D

    ZIO

    B1D1

    FC

    S

    0201D

    ZIC

    0201D

    SOV

    0201D

    XV

    0201D

    ZSC

    0201D

    ZSO

    0201D

    ZIO

    B1D1

    FC

    0201

    FT

    0202

    PT

    0202

    TT

    0204

    TI

    0205

    PI

    FT

    0202

    PT

    0203

    TT

    0203

    TI

    0205

    PI

    0206

    0201

    FQ

    0201

    FI

    0201

    FE

    0201

    CC

    DWG NO

    . 1135

    0202C

    ZIO

    0202C

    ZSO

    0202C

    ZSC

    0202C

    ZIC

    D1B1

    FC

    16"-P-D1-1017C

    0202C

    XV

    0201C

    ZIO

    0201C

    ZSO

    0201C

    ZSC

    0201C

    ZIC

    D1B1

    FC

    1"-P-D1-1023C

    0201C

    XV

    0202B

    ZIO

    0202B

    ZS0

    0202B

    ZSC

    0202B

    ZIC

    D1B1

    FC

    16"-P-D1-1017B0202B

    XV

    0201B

    ZIO

    0201B

    ZSO

    0201B

    ZSC

    0201B

    ZIC

    D1B1

    FC

    1"-P-D1-1023B

    0201B

    XV

    0202A

    ZIO

    0202A

    ZSO

    0202A

    ZSC

    0202A

    ZIC

    D1B1

    FC

    16"-P-D1-1017A

    0202A

    XV

    0201A

    ZIO

    0201A

    ZSO

    0201A

    ZSC

    0201A

    ZIC

    D1B1

    FC

    1"-P-D1-1023A

    0201A

    XV

    DWG NO. 1203

    TO 1-V-251C

    DWG NO. 1103

    TO 1-V-251B

    DWG NO. 1003

    TO 1-V-251A

    DWG NO. 1003

    0207

    PT

    0201

    PI

    0204D

    PDI

    0204D

    PDT

    UCP

    UCP UCP

    NOTE-2ESD/UCP

    1"-P-D1-1023D

    16"-P-B1-1017D16"-P-D1-1017D

    UCP UCP

    NOTE-2ESD/UCP

    0204E

    PDI

    0204E

    PDT

    UCP

    1"-P-D1-1023E

    UCP UCP

    NOTE-2ESD/UCP

    16"-P-D1-1017E

    UCP UCP

    NOTE-2ESD/UCP

    TO 1-V-251E

    3/4"1-PK-266

    INLET GAS METERING SYSTEM

    NOTE-4

    HP PLARE

    B1

    A11.5

    "-FL-A1-2411

    2100 MM

    10" LOW

    POINT

    30"-P-B1-1007

    30"-P-B1-1007

    NOCSC

    1"

    B1

    A1

    FE

    0202

    NC

    FX

    0201

    1"-

    FL-A1-2419

    NO

    1"-P-B1-1016

    SS TUBING

    TO GAS CHROMATOGRAPH

    REFER DETAIL-A IN

    DWG NO. 1011

    FROM GAS

    CHROMATOGRAPH

    REFER DWG NO. 1011

    30"-P-B1-1007

    NO

    3/4"

    B1

    A1

    1"

    CSC

    1"-

    FL-A1-2420

    1"-

    FL-A1-2432

    LP FLARE

    DWG NO

    . 1135

    1-PK-266

    INLET GAS METERING SYSTEM

    2700 KPa(g) / 180CFUTURE

    16"

    FUTURE

    16"

    30"-P-B1-1007

    16"-P-B1-1017C

    16"-P-B1-1017B

    16"-P-B1-1017A

    0204A

    PDI

    0204A

    PDT

    UCPUCP

    UCPUCP

    TO STATION

    CONTROL PANEL

    0204B

    PDI

    0204B

    PDT

    UCP

    UCP UCP

    UCP UCP

    0204C

    PDI

    0204C

    PDT

    UCPUCP

    UCPUCP

    2. REFER NOTE-41 OF LEGEND P&ID 3713-00-02-41-0110

    AND 0111. FOR SOV ASSEMBLY

    4. ALL ITEMS ARE SUPPLIED LOOSE BY GAS METERING VENDOR

    ASSEMBLY TO BE DONE BY 'SHI'

    0202C

    SOV

    IAS

    S

    0201A

    SOV

    S

    NOTE-2 ESD/UCP

    0202A

    SOV

    S

    NOTE-2

    ESD/UCP

    0201B

    SOV

    S

    NOTE-2

    ESD/UCP

    0202B

    SOV

    S

    NOTE-2

    ESD/UCP

    0201C

    SOV

    CMRS

    NOTE-2

    ESD/UCP

    NOTE-2

    ESD/UCP

    30"-P-B1-1050

    VENDOR (NOTE-4)

    ITEM No.:

    ITEM NAME:

    DES. PRESS./DES. TEMP.:

    UCP

    UCP

    NOTES:

    S

    II

    II II

    II II

    II

    II

    II

    IIII

    II II

    II

    II

    IIII

    II II

    II

    II

    II

    II

    II

    II

    II II

    II II

    II

    II II

    IIII

    II

    II

    LEGEND:

    14 1213 91011 678 451516

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    wil

    l not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    30011420523173

    Path\File name\Initials:

    HP INLET SCRUBBER, COMPRESSOR & INTERSTAGE COOLER (TRAIN'A')Document title:

    Page(s)Company's document No.:

    37131003Path\File name\Initials:

    DISTRIBUTION CODE:

    NOTES

    1. UCP REFERS TO UNIT CONTROL PANEL

    3713-00-02-41-0110 &

    TAG. NO. SET POINT

    4400 kPa(g)PAHH-0308A

    750 kPa(g)PALL-0303A

    900 kPa(g)PAH-0304A

    800 kPa(g)PAL-0304A

    0301A

    PSV

    ITEM NO.:

    ITEM NAME:

    SIZE:

    DESIGN PRESS :

    DESIGN TEMP. :

    LINING :

    DWG NO

    . 1136

    4"-

    FL-A1-2406A

    4"-

    SV-A1-2505A

    4"-

    SV-A1-2506A

    TO HP FLARE

    5500

    1.5G2.5

    CSO CSO

    2"-P-D1-1067A

    CSCCSO

    3/4" 3/4"

    2"

    A1

    D1

    FIRE

    CASE CASE

    FIRE

    5500

    1.5G2.5

    0302A

    PSV

    16"-P-D1-1030A

    DWG NO. 1002

    SUCTION HEADER

    FROM HP COMPRESSOR

    0302A

    LG

    0301A

    LT

    0301A

    LIC

    LAH

    LAL

    M

    1-V-251A0304A

    LSHH

    LSLL

    0303A

    0304A

    LAHH

    0303A

    LALL

    1-K-253A TRIP

    CLOSE

    XV-0302A

    2"

    DIFF. PR. :

    CAPACITY :

    ITEM NAME:

    ITEM NO.:

    FROM PT-0207

    DWG NO. 1002

    DWG NO. 1136

    TO HP FLARE

    S

    1-K-253A TRIP

    LSLL-0303A

    FROM

    0302A

    ZIC

    0302A

    SOV

    CMR

    IAS

    0302A

    XV

    0302A

    ZSC

    0302A

    ZSO

    0302A

    ZIO

    D1A1

    FC

    0301A

    LY

    FC

    2"

    3/4"3/4"

    2"-P-D1-1029A

    0301A

    LV

    1"

    I/P

    3/4"

    D1

    A1

    TO COH

    DWG NO

    . 1137

    1-DGT-253A

    HP COMPRESSOR

    9.219 MW

    GAS TURBINE DRIVER

    16"-P-D1-1017A

    2"-P-D1-1051A

    2"-DH-A1-2201A

    SS TUBING

    3/4"

    INST. DRAIN

    STATION

    CONTROL

    PANEL

    TOL

    0301A

    ZIC

    CMR

    0301A

    SOV

    S

    14"-P-D1-1037A

    FO

    0301A

    ZSC

    UCP UCP

    0301A

    ZSO

    0301A

    ZIO

    V/F V/F

    V/F

    UCP

    0301A

    FY

    V/F

    I/P

    NOTE-6

    0301A

    FV

    4"

    V/F

    SURGE CONTROL

    FROM PT-0501

    DWG NO. 1005

    DWG NO. 1150

    METHANOL

    PIPING INST.

    E1D1

    3/4"12MM SS TUBING

    NNF

    EPOXY (INTERNAL)

    180C

    5500 kPa(g)

    2110 mm(ID) x 3025 mm(T/T)

    H.P. INLET SCRUBBER

    1-V-251A1-AC-251A

    H.P. INTERSTAGE COOLER

    DUTY: 25.936 MMKJ/Hr (7.204 MW)

    5500 kPa(g)180C

    1st STAGE

    75450 Nm3/hr (GUARANTEE)

    HP COMPRESSOR

    1-K-253A

    3107 kPa

    V/FUCP

    1-K-253A

    0301A

    XITO UCP "B"

    DWG NO. 1103

    DWG NO. 1203

    TO UCP "C"

    TO UCP "D"

    DWG NO. 1303

    TO UCP "E"

    DWG NO. 1403

    FAST

    STOP

    STOP

    NORMAL

    CLOSE

    XV-4601A, XV-0302A, XV-0401A, XV-0402AON 1-K-253A TRIP

    0302A

    USD

    0301A

    UA

    COMMON

    M/C PARAMETERTRIPALARM

    M/C PARAMETERCOMMONSTART

    PRESSUR1-

    SATION

    0303A

    PB

    0304A

    PB

    MACHINE

    START

    ESD SIGNAL

    FROM PLC-1/2(FAST STOP)

    1-K-253A TRIP

    PLC-1 (NORMAL S/D)

    DWG NO. 1153

    FROM 1-P-356A

    12MM SS TUBING

    SS LSS

    0304ADWG NO. 1004

    COMPR. DISCHARGE

    ON 2nd STAGE

    FROM PIC-0410A

    BIASSIC

    0301A

    V/F

    CONTROL

    SPEED

    GOVERNOR

    ST

    0301A

    V/F

    12"x16"

    10"x12"

    TI

    0305A

    PI

    0305A

    PSLL

    0312A

    PT

    0310A

    1-DGT-253A 1-K-253A

    UCP

    V/FNOTE-13

    V/F

    PT

    0304A0304A

    PIC

    PAH

    PAL

    TS

    0311A

    PDI

    ST-0301A

    NOTE-10

    V/F

    0301A

    TI

    0301A

    TT

    UCP

    0303A

    PSLL

    0303A

    PALL

    16"-P-D1-1030A

    NOTE-8

    TAH

    TAL

    FT

    0301A

    V/FPT

    0306A

    PSLL

    0307A

    PSHH

    0308A 0308A

    PAHH

    UCP

    0307A

    PALL

    UCP

    TI

    0303A

    PI

    0309A

    PAL

    PAH

    NOTE-8

    0306A

    PI

    UIC-0301A

    V/F

    V/F

    TAH

    NOTE-8

    0304A

    TT

    0304A

    TI

    V/F

    0307A

    TAHH

    0307A

    TSHH

    I UCP

    12"-P-D1-1031A-IS

    3/4"

    SS

    D1 PIPING

    INST.

    3/4"

    NOTE-11

    1-AC-251A DWG NO. 1004

    TO 1-V-252A

    3/4"

    8"-P-D1-1037A

    M

    0301A

    VSHH

    0301A

    VAHH

    MOTOR

    S/D

    * *

    0302A

    VAHH

    0302A

    VSHH

    MS/DMOTOR

    0303A

    XI

    0301A

    PB

    FROM

    VSHH-0301A

    NOTE-9

    VSHH-0302A

    FROM

    0302A

    PB

    NOTE-9

    FROM TT-0306A

    DWG NO. 1004

    TAL

    TAH

    0306A

    TIC

    0306A

    TYI/P

    TOL

    12"-P-D1-1032A

    2. UIC REFERS TO ANTISURCE CONTROLLER

    3. REFER LEGEND P&ID No.

    3713-00-02-41-0111 FOR NOTES.

    4. DELETED

    5. DELETED

    6. LOCATE FV-0301A CLOSE TO TAP-OFF POINT.

    7. DELETED

    8. ALL THESE INDICATIONS SHALL BE AVAILABLE ON

    DCS AS WELL AS COMPRESSOR UCP.

    LOCAL CONTROL ROOM.

    9. LOCAL/REMOTE SELECTOR FOR FAN START SHALL BE IN

    10. USE 20 MESH PER VENDOR REQUIREMENT.

    11. INJECTION QUILL TO BE AS PER CORROSION INHIBITOR

    SYSTEM VENDOR REQUIREMENT.

    12. DUAL PLATE WAFER TYPE.

    CONTROL

    13. THIS PSLL SHALL BE UTILISED BY SOLAR FOR LUBE OIL PUMP

    14. UCPS OF FIVE COMPRESSOR TRAINS ARE SERIAL LINKED TO ONE

    STATION CONTROL PANEL.

    2300 kPa(g)PALL-0307A

    50 CTAH-0306A

    44 CTAL-0306A

    170 CTAHH-0307A

    400MM FROM BTLLAH-0301A

    LAL-0301A 200MM FROM BTL

    465MM FROM BTLLAHH-0304A

    150MM FROM BTLLALL-0303A

    TAH-0304A 165 C

    TAL-0301A 45 C

    TAH-0301A 55 C

    4250 kPa(g)PAH-0306A

    3200 kPa(g)PAL-0306A

    VAHH-0302A

    VAHH-0301A

    20 kPaPDI-0311A(MAX)

    LEGEND:

    VENDOR'S SCOPE (SOLAR)

    V/F VENDOR'S SCOPE OF SUPPLY (SOLAR)

    COOLER VENDOR'S SCOPE OF SUPPLY*

    2"-P-D1-1066A

    OVERRIDE

    SOFT

    UCP

    0302A

    XI

    NOTE-12

    I

    I

    I

    II

    II

    I

    I

    I

    I

    I

    I

    I

    I

    I I

    14 1213 91011 678 451516

    This draw

    ing

    and

    the

    design

    it co

    vers are

    the

    prop

    erty of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are

    nere

    ly

    loan

    ed and

    on the

    borrow

    er's expres

    s ag

    reem

    ent

    that they

    will not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    limited way and priva

    te use perm

    itted by any written consent g

    iven by

    tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    NC

    NOTE-14V/F

    PB

    0306A

    PB

    0305A

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    40011420523173

    Path\File name\Initials:

    Document title:

    Page(s)Company's document No.:

    37131004Path\File name\Initials:

    DISTRIBUTION CODE:

    TAG. NO. SET POINT

    TAL-0406A

    TAHH-0409A

    LAH-0401A

    LAL-0401A

    LAHH-0404A

    LALL-0403A

    LAHH-0408A

    LALL-0407A

    400 MM FROM BTLLAH-0402A

    LAL-0402A 200 MM FROM BTL

    4250 kPa(g)PAH-0401A

    PAL-0401A

    TAL-0401A 44 C

    TAH-0401A 50 C

    13000 kPa(g)PAH-0405A

    10500 kPa(g)PAL-0405A

    VAHH-0402A

    VAHH-0401A

    20 kPaPDI-0412A(MAX)

    LEGEND:

    V/F VENDOR'S SCOPE OF SUPPLY (SOLAR)

    COOLER VENDOR'S SCOPE OF SUPPLY*

    DWG NO. 1008

    ACCUMULATOR

    DWG NO. 1124

    TO OILY WATER TREATMENT

    S

    0401A

    ZIC

    0401A

    SOV

    CMR

    IAS

    0401A

    XV

    0401A

    ZSC

    0401A

    ZSO

    0401A

    ZIO

    D1B1

    FC

    S

    0402A

    ZIC

    0402A

    SOV

    CMR

    0402A

    XV

    0402A

    ZSC

    0402A

    ZSO

    0402A

    ZIO

    E1A1

    FC

    2"-P-E1-1074A

    0405A

    LG

    0401A

    LT

    0401A

    LIC

    M

    1-V-252A 0404ALSHH

    LSLL

    0403A

    0404A

    LAHH

    0403A

    LALL

    1-K-253A TRIP

    CLOSE

    XV-0401A

    2"

    0401A

    LY

    FC

    2"

    3/4"3/4"

    0401A

    LV

    2"

    I/P

    D1

    A1

    TO CDH

    DWG NO

    . 1137

    2"-DH-A1-2202A

    SS TUBING3/4"

    INST. DRAIN

    FROM 1-AC-251A

    DWG NO. 100312"-P-D1-1032A NO POCKETS

    2"-P-D1-1036A

    DWG NO. 1003

    TO 1-DGT-253A SPEED CONTROL

    DWG NO. 1003

    TIC-0306A

    DWG NO. 1146

    TO FUEL GAS SKID

    0401A

    ZIO

    0401A

    ZSO

    0401A

    ZSC

    0401A

    ZIC

    F1D1

    FO

    0403A

    SOV

    CMRS

    0401A

    FV

    0401A

    PSV

    DWG NO

    . 1136

    3"-FL-A1-2407A

    3"-SV-A1-2507A

    TO HP FLARE

    CSO CSO

    2"-P-D1-1041A

    CSCCSO

    3/4"3/4"

    2"

    A1

    D1

    FIRE

    CASE CASE

    FIRE

    0402A

    PSV

    8400

    1E2

    8400

    1E2

    PI

    0402A

    TI

    0402A

    PSLL

    0412A

    UCP

    V/F

    NOTE-8

    0412A

    PALL

    TS

    ST-0401A

    TT

    0401A

    V/F

    0401A

    TI

    0401A

    FY

    METHANOL

    DWG NO. 1150

    UCPUCP

    4"-P-F1-1125A-IS

    UCP

    0403A

    RO

    0403A

    PSV

    DWG NO

    . 1136

    6"-FL-A1-2408A

    6"-SV-A1-2516A

    6"-SV-A1-2509A

    TO HP FLARE

    CSO CSO

    CSCCSO

    3/4"3/4"

    2"

    A1

    F1

    0404A

    PSV

    14000

    2J3

    14000

    2J3

    0401A

    RO

    0406A

    LG

    0402A

    LT

    0402A

    LIC

    LAH

    LAL

    M

    1-V-253A

    0408A

    LSHH

    LSLL

    0407A

    0408A

    LAHH

    0407A

    LALL

    CLOSE

    XV-0402A

    2"

    FC

    3/4"

    E1

    A1

    TO CDH

    DWG NO

    . 1137

    2"-DH-A1-2203A

    SS TUBING

    3/4"

    INST. DRAIN

    DWG NO. 1005

    TO DISCHARGE

    TT

    0406A0406A

    TI

    TSHH

    0409A0409A

    TAHH

    UCP

    *

    0402A

    VAHH

    0402A

    VSHH

    MVSHH-0402A

    FROM

    0402A

    PB

    0402A

    XI

    0401A

    VAHH

    0401A

    VSHH

    M

    VSHH-0401A

    FROM

    0401A

    PB

    0401A

    XI

    0402A

    LY

    FROM 1-P-357A

    DWG NO. 1154

    3/4" 3/4"

    3/4"

    TI

    0407A

    12MM SS TUBING

    NO POCKETS

    8"-P-E1-1035A

    8"-P-E1-1070A

    8"-P-E1-1038A

    NO POCKETS

    NOTE-710"-P-D1-1070A

    12MM SS TUBING

    NNF

    NO POCKETS 3"-P-D1-1069A

    0402A

    CC

    ITEM NO.

    ITEM NAMESIZE :

    DESIGN PRESS :

    DESIGN TEMP :

    LINING :

    1-V-252A

    H.P. INTERSTAGE SCRUBBER

    1710 mm (ID)X 2750 mm(T/T)8400 kPa(g)

    180C

    EPOXY (INTERNAL)

    1-AC-252A

    H.P. DISCHARGE COOLER

    DUTY: 22.236 MMKJ/H (6.177 MW)14000 kPa(g)

    180C

    1-V-253A

    H.P. DISCHARGE

    SCRUBBER

    1122 mm (ID) X 2415 mm(T/T)14000 kPa(g)

    65C

    EPOXY (INTERNAL)

    ITEM NO.

    ITEM NAMECAPACITY :

    DIFF. PRESS :

    1-V-254A

    H.P.

    COMPRESSOR

    2nd STAGE

    67696 Nm3/hr8743 kPa

    I

    I

    I

    I

    I

    I

    II

    II I II

    II II

    II

    NC

    TO CONDENSATE

    FROM

    LSLL-0407A,1-K-253A TRIP

    FROM

    LSLL-0403A, LSHH-0807

    PSHH-0805, 1-K-253A TRIPLAH

    LAL

    D1

    F1

    10"x12"

    6"x8"

    TOP

    ENTRY

    2"-P-D1-1044A

    3"-SV-A1-2508A

    0306A

    TT

    2"-P-D1-1071A

    0402A

    RO

    21.05

    12"-P-D1-1033A

    V/FPT

    0401A

    0401A

    PI PAH

    PAL

    NOTE-3

    NOTE-3

    TAH

    TAL

    NOTE-5

    PID

    0412A

    I

    UCP

    I

    PSLL

    0411A

    TI

    0404A

    PT

    0405A

    PI

    0408A

    0405A

    PI

    V/FPAH

    PAL

    NOTE-3

    PSLL

    0407A

    0407A

    PALL

    F1

    SS

    PIPING

    INST.

    II II0405A

    TAHH

    0409A

    PAHH

    0408A

    TI

    TSHH

    0405A

    PSHH

    0409A

    TT

    0408A

    FT

    0402A

    FT

    0401A

    V/F V/F

    V/F

    TAH

    NOTE-3

    F1SS

    INST. PIPING

    IS

    3"

    V/F

    E1F1

    II II

    UCPUCP

    UCP

    V/FI/P

    70.99

    IS

    53.79

    NO POCKETS

    6"-P-F1-1043A-

    IS

    6"-P-F1-1042A-IS

    6"-P-F

    I-1073A-

    IS

    0401A

    PIC

    PT

    0401A

    GAS HEADER

    TAH

    TAL

    VENT

    F1

    E1

    NOTE-4MOTOR

    S/D S/D

    MOTOR NOTE-4

    1-K-253A TRIP

    I/P

    0402A

    LY

    1"1" NC

    HP GAS COMPRESSION & CONDENSATE SEPARATOR TRAIN-A

    TAH-0408A 165 C

    3200 kPa(g)

    150 MM FROM BTL

    465 MM FROM BTL

    50 MM FROM BTL

    774 MM FROM BTL

    130 MM FROM BTL

    290 MM FROM BTL

    55 C

    35 C

    TAH-0406A 50 C

    TAHH-0405A 172 C

    2300 kPa(g)PALL-0412A 4500 kPa(g)PALL-0407A13200 kPa(g)PAHH-0409A

    1. REFER LEGEND P&ID No.

    3713-00-02-41-0110 &

    3713-00-02-41-0111 FOR NOTES.

    2. LOCATE FV-0401A CLOSE TO TAP-OFF POINT.

    3. ALL THESE INDICATIONS SHALL BE AVAILABLE ON

    DCS AS WELL AS COMPRESSOR UCP.

    4. LOCAL/REMOTE SELECTOR FOR FANS START SHALL BE IN LOCAL CONTROL ROOM.

    5. USE 20 MESH PER VENDOR REQUIREMENT.

    6. INJECTION QUILL TO BE AS PER CORROSION INHIBITOR

    SYSTEM VENDOR REQUIREMENT.

    7. DUAL PLATE WAFER TYPE.

    8. THIS PSLL SHALL BE UTILISED BY SOLAR FOR LUBE OIL

    PUMP CONTROL.

    VENDOR'S SCOPE

    NOTES:

    UCI-0401A

    V/FV/F V/F

    V/F

    NOTE-2

    1-K-254A

    VENT

    14 1213 91011 678 451516

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    will not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    1-AC-252A

    3/4"

    0401A

    CC

    NOTE-6

    8"-P-F1-1034A-

    IS

    IAS

    3/4"

    *

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    50011420523173

    Path\File name\Initials:

    HP COMPRESSOR DISCHARGE MANIFOLDDocument title:

    Page(s)Company's document No.:

    37131005Path\File name\Initials:

    DISTRIBUTION CODE:

    NOTES:

    TAG. NO. SET POINT

    250 kPa(g)PAL-0501 A/B/C/D/E

    50CTAH-0501

    35CTAL-0501

    13000 kPa(g)PAH-0501

    1. DELETED.

    2. REFER NOTE-41 OF LEGEND P&ID NO. 0110/0111 FOR SOV

    3. REFER LEGEND P&ID No. 3713-00-02-41-0110

    10500 kPa(g)PAL-0501

    & 3713-00-02-41-0111 FOR NOTES.

    ASSEMBLY DETAILS. IN ADDITION, A PUSH BUTTON MOUNTED IN SSD

    PANEL IN LCR SHALL BE PROVIDED TO OPEN THE BLOWDOWN VALVE.

    4. REFER NOTE-42 OF LEGEND P&ID NO. 3713-00-02-41-0110 & 0111

    FOR SOV ASSEMBLY DETAILS.

    5. DELETED.

    6. DUAL PLATE WAFER TYPE.

    7. ALL DEAD ENDS LONGER THAN 5M OF FLARE AND VENT HEADERS

    SHALL BE PROVIDED WITH PURGE CONNECTIONS. FOR PURGE CONN.

    REFER P&ID NO. 1135. FLARE HEADERS SHALL BE PURGED WITH

    FEUL GAS AND VENT HEADERS WITH INERT GAS.

    DWG NO. 1136

    DWG NO. 1136

    DWG NO. 1008

    VENT

    FLOW TEMPERATURE

    FLARE

    TO 1-T-311A/B

    SEAL GAS

    DWG NO. 1056

    2"-P-E1-1160

    I

    0511

    ZSC

    0511

    ZSO

    0511

    ZIO

    0511

    ZIC

    0511

    XBDV

    S

    0511

    SOV

    NOTE-4

    ESD

    E17E1

    FOCSO

    RO

    0501

    6.43

    CSO

    E17 A17

    2"x3"2"-P-E1-1133

    NO POCKETS

    4"-VG-A1-2834

    6"-FL-A17-2408

    16"-P-E1-1040

    NO POCKETS

    2 : 1000

    CC

    0501

    TT

    0501

    0501

    TITAH

    TAL

    8"

    FUTURE FUTURE

    4"

    FUTURE

    2"

    NOTE-7

    A1E1

    CSC

    0502A

    RO

    0505A

    ZSC

    0505A

    ZIC

    I

    UCP

    ALARM

    17.98

    NC

    2"-P-E1-1127A

    II

    I

    UCPUCP

    0500A

    ZIO

    0500A

    ZSO

    0500A

    ZIC

    0500A

    ZSC

    0500A

    XV

    UCP/ESD

    0500A

    SOV

    NOTE-2

    S

    FC

    DWG NO. 1004

    FROM 1-V-253A

    8"-P-E1-1038A

    0501A

    PSL

    0501A

    PAL

    2"

    NOTE-6

    3/4"

    2"-P-E1-1039A

    FO

    S

    NOTE-2

    0510A

    SOV

    0510A

    XBDV

    0510A

    ZSC

    0510A

    ZIC

    0510A

    ZSO

    0510A

    ZIO

    UCPUCP

    I

    II

    CSO

    E1

    E17

    UCP/ESD

    15.04

    RO

    0500A

    2"x4"

    A17E17

    CSO

    17.98

    0502E

    RO

    A1 E1

    CSC

    NC

    8"-P-E1-1127E

    0505E

    ZSC

    0505E

    ZIC

    UCP

    I

    ALARM

    I

    I

    I

    UCPUCP

    0500E

    ZIO

    0500E

    ZSO

    0500E

    ZIC

    0500E

    ZSC

    0500E

    XV

    UCP/ESD

    0500E

    SOV

    NOTE-2

    S

    FC

    2"

    NOTE-6

    3/4"

    FROM 1-V-253E

    DWG NO. 1404

    CSO

    E17A17

    2"x4"

    RO

    0500E

    15.04

    UCP/ESD

    E1

    CSO

    I

    I

    I

    UCPUCP

    0510E

    ZIO

    0510E

    ZSO

    0510E

    ZIC

    0510E

    ZSC

    0510E

    XBDV

    0510E

    SOV

    NOTE-2

    S

    FO

    2"-P-E1-1039E

    FROM

    E17

    17.98

    ALARM

    UCP

    I

    0505B

    ZIC

    0505B

    ZSC

    0502B

    RO

    CSC

    E1 A1

    2"-P-E1-1127B

    NC

    0501B

    PAL

    0501B

    PSL

    8"-P-E1-1038BFROM 1-V-253B

    DWG NO. 1104

    E17

    E1

    CSO

    I

    UCPUCP

    0510B

    ZIO

    0510B

    ZSO

    0510B

    ZIC

    0510B

    ZSC

    0510B

    XBDV

    0510B

    SOV

    NOTE-2

    S

    FO

    3/4"

    NOTE-6

    2"FC

    S

    NOTE-2

    0500B

    SOV

    0500B

    XV

    0500B

    ZSC

    0500B

    ZIC

    0500B

    ZSO

    0500B

    ZIO

    UCP

    UCP

    I

    CSO

    E17 A17

    2"x4"

    RO

    0500B

    15.04I

    I

    I

    UCP/ESD

    2"-P-E1-1039B

    UCP/ESD

    I

    A1E1

    CSC

    0502C

    RO

    17.98

    0505C

    ZSC

    0505C

    ZIC

    I

    UCP

    ALARM

    NC

    2"-P-E1-1127C

    DWG NO. 1204

    FROM 1-V-253C

    8"-P-E1-1038C

    0501C

    PSL

    0501C

    PAL

    I

    UCP/ESD

    2"-P-E1-1039C

    UCP/ESD

    I

    I

    I15.04

    RO

    0500C

    2"x4"

    A17E17

    CSO

    I

    UCPUCP

    0500C

    ZIO

    0500C

    ZSO

    0500C

    ZIC

    0500C

    ZSC

    0500C

    XV

    0500C

    SOV

    NOTE-2

    S

    FC

    2"

    NOTE-6

    3/4"

    FO

    S

    NOTE-2

    0510C

    SOV

    0510C

    XBDV

    0510C

    ZSC

    IAS

    0510C

    ZIC

    0510C

    ZSO

    0510C

    ZIO

    UCP

    UCP

    I

    CSO

    E1

    E17

    DWG NO. 1003

    CONTROL PANEL

    TO STATION

    0501

    PT

    0501

    PI

    PAL

    PAH

    8"-P-E1-1038E

    0501E

    PSL

    0501E

    PAL

    0501D

    PAL

    0501D

    PSL

    8"-P-E1-1038D

    E17

    2"-P-E1-1039D

    FO

    0510D

    XBDV

    0510D

    ZSC0510D

    ZSO

    CSO

    E1

    RO

    0500D

    3/4"

    NOTE-6

    2"

    FC

    S

    NOTE-2

    0500D

    SOV

    UCP/ESD

    0500D

    XV

    0500D

    ZSC

    0500D

    ZIC

    0500D

    ZSO

    0500D

    ZIO

    UCPUCP

    I

    I

    I

    ALARM

    I

    UCP 0505D

    ZIC

    0505D

    ZSC

    NC

    CSC

    E1A1

    0502D

    RO

    8"-P-E1-1127D

    2"x4"CSO

    A17 E17

    S

    NOTE-2

    0510D

    SOV

    0510D

    ZIC0510D

    ZIO

    UCPUCP

    I

    I

    I

    UCP/ESD

    15.04

    DWG NO. 1304

    FROM 1-V-253D

    17.98

    FUTUREFUTUREFUTURE

    8" 4" 2"

    NOTE-7

    16"-P-E1-1040

    16"-FL-A17-2408

    4"-VG-A1-2634

    14 1213 91011 678 451516

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    wil

    l not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

    IAS

  • 123

    LALL-0604 (-)105MM FROM BTL

    LAHH-0603 195MM FROM BTL

    TAHH-0602/04/06

    TAL-0601

    TAH-0601 60C

    PAL-0601

    PAH-0601

    PAL-0605 260 kPa(g)

    2. REFER LEGEND P&ID NO. 3713-00-02-41-0110 AND

    PAH-0605 370 kPa(g)

    PAHH-0606 400 kPa(g)

    PALL-0604 (-)8.8 kPa(g)

    PAHH-0609 40 kPa(g)

    SET POINTTAG. NO.

    1. DELETED.

    NOTES

    DISTRIBUTION CODE:

    Path\File name\Initials: 37131006

    Company's document No.: Page(s)

    Document title: COMPRESSION OF LOW PRESSURE GAS FROM CPP2

    Path\File name\Initials:

    7 1 3 2 5 0 2 4 1 1 0 0 6

    Contractor's document identification:

    B

    Rev.

    Company's contract No.:

    CCP-WT/95

    Type of documentSCALE

    PIPING & INSTRUMENTATION DIAGRAM

    Project name: PETROVIETNAM GAS UTILISATION PROJECT

    CENTRAL COMPRESSION PLATFORM

    WHITE TIGER FIELD

    Basic Engineering:

    Detailed Engineering:

    NEW DELHI - INDIA

    ENGINEERS INDIA LIMITED

    WorleyLimited

    Contractor:

    Company;

    VIETSOVPETRO

    PETECHIM/VIETSOPETRO

    Date

    DD-MM-YYDescription of revision COMPANYSHIWORLEYEILEIL

    31.8.95 ISSUED FOR KICK OFF MEETING

    TITLE BLK REV. FOR COMMENTS11.9.95 GB/NL SS/AC

    ACNL/SS25.9.95 ISSUED FOR PRELIMINARY HAZOPS

    ISSUED FOR CLIENT'S APPROVAL15.10.95 GRR SS

    SSGRR03.11.95 ISSUED FOR COMPANY'S APPROVAL

    APPROVED FOR ENGG.10.1.96 MSP GRR

    GRRMSP7.2.96 APPROVED BY COMPANY FOR ENGG. PH JUY LOC

    LOCJUYPH APPROVED FOR CONSTRUCTION20.3.96 MSP AC

    SDHSA20.11.96 REVISRD AS MARKED ISH

    AS - BUILT14.3.97

    CONSORTIUM

    BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    Rev.

    A

    B

    C

    D

    E

    0

    1

    2

    3

    B

    3713-00-02-41-0111 FOR NOTES.

    3. REFER NOTE-41 OF 3713-00-02-41-0110 AND

    3713-00-02-41-0111 FOR SOV ASSEMBLEY DETAILS.

    4. VENDOR TO PROVIDE A TEMPERED WATER JACKET COOLING

    SYSTEM TO PREVENT HYDROCARBON. CONDENSATION IN

    THE COMPRESSOR.

    5. ALL INSTRUMENTATION AND CONTROL ITEMS EXCEPT THOSE

    INDICATED AS IN DCS SHALL BE SUPPLIED BY PACKAGE VENDOR.

    6. COMPRESSOR SHALL HAVE A UNIT CONTROL PANEL (UCP) IN THE

    CONTROL ROOM, AND A LOCAL PANEL (LCP) IN THE FIELD.

    - ALL PROCESS/MECHANICAL TRIP INTERLOCKS SHALL BE EXECUTEDIN THE UCP. WITH THE ALARMS SERIAL LINKED TO THE DCS.

    - LCP SHALL CONTAIN COMPRESSOR START/STOP PUSH BUTTONSAND INDICATIONS FOR AUXILIARY FACILITIES.

    - START PERMISSIVE FOR COMPRESSOR SHALL BE FROM THE UCP.

    7. 1-AC-253 IS SUPPLIED LOOSE BY VENDOR. PIPING TO/FROM1-AC-253 SHALL BE IN PURCHASER'S SCOPE.

    8. LOCAL/REMOTE SELECTOR SWITCH FOR 1-AC-253 START SHALL BEIN THE CONTROL ROOM.

    9. ON ACTUATION OF TDAL -0705 (P&ID NO. 1007). OPERATOR SHOULDCHANGE XV-0603 TO ROUTE GAS THROUGH 1-AC-253.

    10. 25-TI-0603 & 25-TT-0602 PROVIDED AT OUTLET OF CYLINDER

    NO.-4 SIMILARLY 25-TI-0613 & 25-TT-0604 PROVIDED AT OUTLET

    OF CYLINDER NO.-2 AND 25-TI-0615 & 25-TT-0606 PROVIDED

    AT OUTLET OF CYLINDER NO.-1.

    11. TYPICAL ARRANGEMENT FOR EACH CYLINDER.

    12. FROM VOLUME BOTTLE D3.

    36 kPa(g)

    (-)5 kPa(g)

    40C

    135C

    LAH-0602 125MM FROM BTL

    LAL-0602 (-)25MM FROM BTLTAH-0607 130C

    TAL-0607 100C

    TAH-0605 98C

    TAL-0605 80C

    VAHH-0601

    PDI-0607(MAX.) 10 kPa(g)

    DWG NO. 1007

    3/4"-DH-A1-2219

    FROM 1-T-T1

    TO CDH

    DWG NO. 11371"-DH-A1-2228

    3/4"

    A1

    B11"-DH-A1-2215

    1"-DH-A1-2218

    NOTE 12

    3/4"12mm SS TUBING

    DWG NO. 1007

    TO 1-V-D5 FOR TIE-IN DETAILS

    P&ID NO. SOP-52599/1

    REFER NUOVO PIGNONE

    DWG NO. 1124

    TO 1-V-453

    2"-P-A1-1053

    FREE DRAIN9

    L1

    DWG NO. 1007

    SKID LIMITS

    RO

    0601

    1/2"FC

    2"

    TSO

    2"

    1/2"

    LV

    0602

    S

    SOV

    0604

    IFROM

    LSLL-0604

    CMR

    S

    SOV

    0602

    AR

    IAS

    0602

    LSL

    0602

    LSHOPEN

    CLOSE

    0602

    LI

    LAH

    LAL

    LG

    0601

    ST-0601

    TS

    PDI

    0607

    14"x16"

    TI

    0609

    PI

    0602

    PSHH

    0609

    I

    UCP

    1-K-251 S/D

    0609

    PAHH

    1

    S

    TO LP FLARE

    DWG NO. 1135

    DWG NO. 1137

    TO CDH

    1.5"-DH-A1-2234

    1"-FL-A1-2470

    LOW

    POINT

    DWG NO. 1133

    LP GAS FROM CPP-2

    16"-P-A1-1052

    21 8

    UCPUCP

    II

    V/F

    ESD

    FROM 1-K-251 S/D.

    I

    0601

    ZSC

    0601

    ZSO

    0601

    ZIO

    0601

    ZIC

    0601

    XV

    S

    IAS

    0601

    SOV

    NOTE-3

    UCP

    FC

    V/F

    8"-P-A1-1015

    8"x4"

    B1

    A1

    PY

    0601

    I/P

    1/2"

    1/2"

    NC

    2"

    FC

    PV

    0601

    N2 PURGE

    SUPPLY

    5

    4"-P-B1-1015

    0602

    ZSC

    0602

    ZSO

    0602

    ZIO

    0602

    ZIC

    NOTE-3

    0605

    SOV

    IAS

    S

    0602

    XV

    I

    FROM 1-K-251 S/D.ESD

    I

    UCP

    I

    UCP

    DWG NO. 1001

    SUCTION HEADER

    FROM HP COMPRESSOR

    FC

    2" VENT

    RO

    0602

    LT

    0602

    LSLL

    0604

    LSHH

    0603

    I

    0603

    LAHH

    0604

    LALL

    I

    UCP

    CLOSE

    LV-0602

    UCP

    1-K-251 S/D

    6"-P-A1-1047

    3"x6"

    CSC

    VF

    VF

    1/2"

    2"

    2"VF

    CSO

    4"x8" 0602

    PSV

    500

    3L4

    VF

    LP FLARE

    DWG NO. 1135

    8"-FL-A1-2410

    8"-

    SV-A1-2511

    8"-

    SV-A1-2510

    VF

    500

    3L4

    0601

    PSV

    4"x8"

    CSOVF

    1/2"VF

    VF

    CSO

    3"x6"

    6"-P-A1-1048

    DESIGN TEMP.

    DESIGN PRESS.

    ITEM NAME :

    ITEM NO. :1-V-254

    LP SUCTION SCRUBBER

    DIA 1352mm x 2192mm (T/T)500 kPa (g) & FULL VAC.100C

    SIZE

    0604

    PSLL

    0604

    PALL

    I UCP

    1-K-251

    S/D0601TI

    0601

    TT

    TAL

    TAH

    6"-P-A1-1045

    27

    14"-P-A1-1054-IE

    V/F

    UCP

    1-K-251

    NOTE-6

    0601

    UA

    0602

    USD

    I

    I

    ESD SIGNAL

    FROM PLC-1/2LSHH 0703

    TRIP XV-0702

    COMMON

    ALARM

    TRIP

    COMMON

    START

    PERMISSIVE

    NOTE-6

    1-K-251

    LCP

    DWG NO. 1007

    L2

    12mm SS TUB

    ING

    DRG NO. 1007

    TO 1-T-231

    TT

    0605

    0608

    TI

    V/F

    TAH

    TAL

    TO

    TX-0705

    P&ID NO. 1007

    TAL

    V/F

    0607

    TI

    TT

    0607

    0603

    ZSO

    0603

    ZSC

    0603

    ZIC

    0603

    ZIO

    I I

    UCP UCP

    0603

    XVV/F

    S

    IAS

    0603

    SOV

    0601

    PB

    NOTE-9

    8"x6"

    8"x6"

    FO8"x6"

    8"-P-A1-1056-IS

    FREE DRA

    INING

    8"-P-A1-1057-

    IS

    V/F1-AC-253

    8"-P-A1-1055-

    IS

    VSHH

    0601

    0601

    VAHH

    I

    V/F

    UCP

    MOTOR

    S/D

    M

    I

    0602

    XI

    1-V-D2/D3

    TI

    0603

    1"

    PSHH

    0606

    0606

    PAHH

    I

    PT

    0605

    PI

    0608

    0605

    PIUCP

    1-K-251

    S/D

    NOTE-5 (TYP.)

    PAH

    PAL

    M0601

    XI

    I

    UCP

    TRIP

    1-K-251

    1"

    RO

    0603

    NOTE-10

    2

    TSHH

    0602

    0602

    TAHH

    I UCP

    1-K-251

    S/D

    NOTE-10

    CSO

    4"x6"

    CSC

    1/2"

    2"

    0604

    PSV

    500

    4P6

    6"-

    SV-A1-2513

    6"-SV-A1-2512

    500

    4P6

    0603

    PSV

    1/2"CSO

    4"x6"

    CSO

    6"-P-A1-1140

    6"-P-A1-1141

    1-V-D1

    DWG NO

    . 1135

    LP FLARE

    6"-FL-A1-2424

    DWG NO. 1007

    6"x8"

    1.5"-FL-A1-2432A

    6

    L3

    DWG. NO. 1007

    7

    NOTE-11

    3"-VG-A1-2637

    TO SAFE

    LOCATION

    CONTINUED ON

    P&

    ID NO

    . 1007

    PT

    0601

    0601

    PIC

    0601

    PAH

    0601

    PAL

    I I

    PAH

    PAL

    UCP

    CAPACITY CONTROL

    1"

    PI

    0603

    TI

    0601

    CAPACITY

    ITEM NO. :

    ITEM NAME :

    DIFF. PRESS.

    310 KPa

    15018 Kg/hr

    LP COMPRESSOR 1st STAGE

    1-K-251

    180C

    500 kPa (g)DUTY: 183.46 KJ/Hr

    LP INTERSTAGE COOLER

    1-AC-253

    TAH

    FC

    4"-P-A1-1139

    NOTE-11

    14 1213 91011 678 451516

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    wil

    l not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    3

    1-V-254

    M

    FROM VSHH-0601

    UCP

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    70011420523173

    Path\File name\Initials:

    Document title:

    Page(s)Company's document No.:

    37131007Path\File name\Initials:

    DISTRIBUTION CODE:

    TAG. NO. SET POINT

    LAHH-0703

    LALL-0701

    LAH-0702

    LAL-0702

    PAHH-0701

    PALL-0702

    PAH-0708

    PAL-0708

    TAHH-0702

    PAH-0705

    900 kPa(g)PAL-0705

    TAH-0704

    PDI-0701(MAX)

    TAL-0704 125 C

    V/F: COMPRESSOR VENDOR SCOPE SUPPLY.

    LOW PRESSURE GAS COMPRESSION & CONDENSATE STRIPPING

    150 kPa(g)

    270 MM FROM BTL

    430 MM FROM BTL

    TDAL-0705 10 C

    TDAH-0705 25 C

    NOTES:

    0702

    LT

    0704

    LG

    0701

    LALL

    2"

    II

    0703

    LSHH

    0701

    LSLL

    FROM 1-K-251 1st. STAGE

    DWG NO. 1006

    0703

    PSV

    DWG NO

    . 1135

    3"-SV-A1-2514

    3"-SV-A1-2515

    TO HP FLARE

    CSO CSO

    CSCCSO

    3/4" 3/4"

    2"

    0704

    PSV

    500

    1.5H3

    500

    1.5H3

    0703

    LAHH

    II

    0701

    ZIO

    0701

    XV0701

    ZSO

    0701

    ZSC

    0701

    ZIC

    FC

    IS

    0701

    SOV

    0701

    RO

    0708

    PI

    2"-P-A1-1171-

    IS

    0709

    PI

    SS TUBING

    DWG NO

    . 1137

    0701

    PB

    0701

    XI

    I

    0702

    PB

    0702

    XI

    I

    DWG NO. 1012

    BLACK CONDENSATE

    TO 1-PK-264

    DWG NO. 1012

    0702

    ZIO

    0702

    XV0702

    ZSO

    0702

    ZSC

    0702

    ZIC

    B1A1

    FC

    IS

    0702

    SOV IAS

    DWG NO. 1001

    0701

    PSV

    DWG NO

    . 1136

    6"-SV-A1-2521

    6"-SV-A1-2522

    TO HP FLARE

    CSO CSO

    CSCCSO

    3/4" 3/4"2"

    0702

    PSV

    1200

    3L4

    1200

    3L4

    4"-P-A1-1105-IS

    4"-P-A1-1106-

    IS

    0703

    RO

    0704

    PI

    0705

    TI

    0705

    TX

    0705

    TDI0702

    TT

    0701

    TI

    0702

    TAHH

    0704

    TT

    0704

    TI

    0705

    PT

    0705

    PI

    0701

    PSHH

    0701

    PAHH

    0708

    PT

    0708

    PI

    0703

    TI

    0702

    PSLL

    0702

    PALL

    0706

    PI

    0701

    PDI

    TS DWG NO. 1001

    DWG NO. 1006

    TAH

    DWG NO. 1006

    DWG NO. 1006

    DWG NO. 1006

    DWG NO. 1006

    0705

    TT

    1-K-252

    LP COMPRESSOR 2nd STAGE

    17077 Kg/hr719 kPa

    1-P-233A/B (NOTE-6)BLACK CONDENSATE PUMPS

    2.0 m3/hr350 kPa

    ITEM NO.

    ITEM NAMECAPACITY

    DIFF. PRESS.

    ITEM NO.

    ITEM NAMESIZE

    DESIGN PRESS.

    DESIGN TEMP.

    1-T-231

    CONDENSATE STRIPPER

    1200 mm (ID) X 8600 mm (T/T)

    500 kPa (g) /F.V140 C

    8"-P-A1-1056-IS FREE DRAINING

    600 MM FROM BTL

    100 MM FROM BTL

    1100 kPa(g)

    231 kPa(g)

    340 kPa(g)

    245 kPa(g)

    1050 kPa(g)

    165 C

    15 kPa(g)

    0602

    LG

    0702

    RO

    STOPLSLL-0701LSLL-0701

    STOP

    3/4"3/4"

    2"X1"2"x1" 3/4"3/4"

    INTS. DRAIN

    2"-P-A1-1173-

    IS

    2"-P-A1-1172-

    IS

    2"-P-A1-1174-

    IS

    3/4"

    S

    2"-P-A1-1058-IS

    3/4"

    FOR PI

    NOTE-5

    FROM ESD.

    LSLL-0701

    7.47

    NC

    2"-P-A1-1058-IS

    2"-DH-A1-2232

    75 MM

    HOTTO CLOSE

    XV-0701

    TRIP 1-P-233A/B

    M2 0702LIC

    LAH

    LAL

    TO LV-0702

    FROM 1-V-211A/BHC LIQUID

    0708

    PDI

    75 MM

    HOT

    LOW POINT

    DRAIN3/4"

    3"-P-A1-1008 3"-P-B1-1008

    LOW POINT

    DRAIN3/4"

    LSHH-0703ON 1-K-251 S/D

    TO 1-V-453

    3/4"-DH-A1-2219

    NOTE-317

    1"-DH-A1-2273

    FROM COMP. CYLINDERS

    I

    UCP

    1-K-251

    S/D

    1.5"-FL-A1-2432A

    16 CSO

    TO 1"-DH-A1-2125

    TO 1-V-211 A/B

    12 mm SS TUBING

    1"

    6"-P-A1-1059-IS

    4

    4"-P-A1-1104-IS

    1"

    TAL

    13

    1"

    3

    1"

    DWG NO. 1006

    L3

    PAH

    PAL

    I

    S/D

    1-K-251

    UCP

    I

    S/D

    1-K-251

    UCP

    REFER NUOVO PIGNONE

    P&ID NO. SOP-52599/1FOR TIE IN DETAILS

    1-K-252

    1-V-D51-V-D4

    L1

    L2

    1-T-T1

    10"-P-A1-1081-

    IE

    NO POCKETS V/F

    6"X3"3"-P-A1-1101-IS

    3"-P-A1-1103-IS

    3"-P-A1-1102-IS

    M1

    1-T-231

    #1

    #10

    1. DELETED.

    2. DELETED.

    3. ALL INSTRUMENTATION AND CONTROL ITEMS EXCEPT THOSE

    INDICATED AS IN DCS/PLC SHALL BE SUPPLIED BY PACKAGE VENDOR.

    4. ROUTE LINE SO THAT SAFETY INSULATION IS MINIMISED.

    5. REFER NOTE-41 OF 3713-00-02-41-0111.

    6. LOCATE PUMPS ON TILTING PLATE SEPARATOR (1-V-453) DECK TO MEET NPSH REQUIREMENTS.

    7. STRAINERS ST-1301/1302 PREVIOUSLY PROCURED FOR 1-P-232 A/B TO BE USED.

    TO 1-K-251 S/DCLOSE XV-0702

    3"-FL-A1-2412

    8"-FL-A1-2413

    6"X8"

    CONTINUED FROM

    P&

    ID NO

    . 1006

    14 1213 91011 678 451516

    This draw

    ing and the design

    it cove

    rs are the property of ENG

    INEERS

    IND

    IA LIM

    ITED

    . They are nere

    ly

    loaned and on the borrower's

    exp

    ress agreement

    that

    they

    wil

    l not be reproduced, cop

    ied,

    loaned, exh

    ibited nor used except

    in the

    lim

    ited way and private use perm

    itted by any written consent g

    iven by tender

    to the borrower.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    J

    K

    L

    16 15 458 7 611 10 9121314 3 2 1

    H

    G

    F

    E

    L

    K

    J

    I

    1-T-T1

    CONTAMINATED LIQUID FLASH DRUMBY VENDOR

    350 kPa (g)65C

    M M

    IAS

    TDAH

    TDAL

    0707

    PI

    PAH

    PAL

    2"-P-A1-1175-IS

    ST-0701

    NOTE-7

    ST-0702

    NOTE-7

  • BOUYSUES OFFSHORE + SAMSUNG HEAVY INDUSTRIES

    CONSORTIUM

    B 14.3.97 AS - BUILT

    ISHREVISRD AS MARKED20.11.963 SA SDH

    ACMSP2 20.3.96 APPROVED FOR CONSTRUCTION PH JUY LOC

    LOCJUYPH APPROVED BY COMPANY FOR ENGG.7.2.961 MSP GRR

    GRRMSP0 10.1.96 APPROVED FOR ENGG.

    ISSUED FOR COMPANY'S APPROVAL03.11.95E GRR SS

    SSGRRD 15.10.95 ISSUED FOR CLIENT'S APPROVAL

    ISSUED FOR PRELIMINARY HAZOPS25.9.95C NL/SS AC

    SS/ACGB/NLB 11.9.95 TITLE BLK REV. FOR COMMENTS

    ISSUED FOR KICK OFF MEETING31.8.95A

    EIL EIL WORLEY SHI COMPANYDescription of revisionDD-MM-YY

    DateRev.

    PETECHIM/VIETSOPETROVIETSOVPETRO

    Company;

    Contractor:

    Limited

    Worley

    ENGINEERS INDIA LIMITED

    NEW DELHI - INDIA

    Detailed Engineering:

    Basic Engineering:

    WHITE TIGER FIELD

    CENTRAL COMPRESSION PLATFORM

    PETROVIETNAM GAS UTILISATION PROJECTProject name:

    PIPING & INSTRUMENTATION DIAGRAM

    SCALE Type of document

    CCP-WT/95

    Company's contract No.:

    Rev.

    B

    Contractor's document identification:

    80011420323173

    Path\File name\Initials:

    CONDENSATE COALESCER & INJECTION PUMPSDocument title:

    Page(s)Company's document No.:

    37131008Path\File name\Initials:

    DISTRIBUTION CODE:

    NOTES:

    3713-00-02-41-0110 &

    TAG. NO. SET POINT

    3800 kPa (g)PAH-0801

    3400 kPa(g)PAL-0801

    3900 kPa(g)PAHH-0805

    3000 kPa(g)PALL-0813

    1. REFER LEGEND P&ID No.

    3713-00-02-41-0111 FOR NOTES.

    2. DELETED

    3. ON ONE RUNNING PUMP TRIP. THE STANDBY PUMP SHALL START

    4500 kPa(g)PALL-0807

    PALL-0809

    PAHH-0810

    PAHH-0812

    2400 mm FROM BTLLAH-0802

    250 mm FROM BTLLAL-0802

    PALL-0811

    PAHH-0808

    LAHH-0807

    LALL-0806

    FAL-0801

    4500 kPa(g)

    2600 mm FROM BTL

    150 mm FROM BTL

    18 m3/hr

    AUTOMATICALLY.

    LOCATED IN LOCAL CONTROL ROOM.

    4. AUTO MANUAL SELECTOR SWITCH FOR 1-P-231A/B/C/ SHALL BE

    5. PUMP SEAL CAVITY BYPASS LINE.

    6. PI-0806 TO BE VISIBLE FROM THIS VALVE

    7. PROVIDE EITHER TRUNION MOUNTED VALVE WITH TWIN SEAL

    AND BODY BLEED OR DOUBLE BLOCK VALVES WITH 3/4" BLEED.

    IAS

    I

    3/4"1"

    FC

    3/4"

    NC

    0801

    LV

    1"

    I/P

    2"-P-B1-1061

    0801

    ZSC

    0801

    ZSO

    0801

    ZIO

    0801

    ZIC

    0801

    XV

    SCMR

    0801

    SOV

    LSLL-0805

    FROM

    B1A1

    FC

    0801

    LY

    DWG NO. 1124

    0801

    LT

    0804

    LG

    0805

    LSLL

    0805

    LALL

    I

    0808

    LSLL

    0807

    PDI

    M

    2"

    VENT

    M

    2"

    VENT

    DWG NO. 1136

    HP FLARE

    DWG NO

    . 1136

    HP FLARE

    6"-

    FL-A1-2409

    A1

    B1

    CS0