1
Peripheral pumpsAQUAMAT
8 M9 T
Description, design and technical data
Basic type
Characteristics of pump size
Single-phase or three-phase motor
Materials of the pump parts:
Electric motor data
- Two pole single-phase or three-phase asynchronous motor- Rated voltage: 1x230V or 3x400V, 50Hz- Degree of mechanical protection: IP54- Insulation class: F- Allowed ambient temperature: 40 C- Protection: pumps are delivered with motor without
protection, so it is necessary to carry out the protection withmotor protection switch
o
- Pump housing: gray iron- Motor housing: Al alloy- Shaft: stainless steel- Impeller: copper alloy
Technical data- Flow: up to 85 l/min- Head: up to 70 m- Suction pressure: max 3 bar- Discharge pressure: max 10 bar- Water temperature: up to 50 C
At the greatest head, the pump AQUAMAT absorbs the greatestpower. For this reason the usage of the pump is allowed within thelimits of the flow and the head designated on diagrams.
o
Standards and marks of quality
Pumps AQUAMAT are in category of domestic appliances. Theyhold all necessary certificates and declarations in accordancewith the directives of the European Union. According to the EUlegislation, they carry the CE sign.They are attested by TÜV Rheinland.Pumps meet the requirements of the following standards:- EN 60335-1- EN 60335-2-41- EN 55014-1- EN 55014-2
Pump designation
Application
Transported liquid
Automatic pumps AQUAMAT are applied for supplying
households, cottages, motels, farms with cold consumption water
and they also can be used for irrigation. They pump water out of
dug, drilled or driven wells, cisterns, tanks and brooks.
Pump is used for transport of cold consumption water with
allowed quantity of sand max 25 g/m and the greatest diameter
of particles up to 0,04mm.
3
Design
Pump is peripheral, single-stage, in monoblock execution withelectric motor. Loose radial coupling of shaft and impellerenables seflpositioning of impeller in pump housing. Pumphousing sealing is done by mechanical seal. At suction anddischarge there are flanges with inner tube thread R1 / ", whichare intended for connection to the pipeline. This enables easy andsimple mounting and dismounting of pump.The main parts of the pump are of high quality and assure long lifepractically without maintenance.
14
A - 9 T
Diagrams of hydraulic characteristics
2
Peripheral pumpsAQUAMAT
�
%
0 10 20 30 40 50 60 70 80 90
1 2 3 4 5
Q, l/min
Q, m /h3
0
Hm
0 10 20 30 40 50 60 70 80 90
1 2 3 4 5
Q, l/min
Q, m /h3
0
P
kW1
0 10 20 30 40 50 60 70 80 90
1 2 3 4 5
Q, l/min
Q, m /h3
2,0
1,5
1,0
0,5
2,5
3,0
INP
UT
PO
WE
R
0
p
barS
100 120 140 160 180 190 U , VZ
STA
TIC
PR
ES
SU
RE
p* S
110 130 150 170
Diagrams of hydraulic characteristics
20 30 40 50 60 70 80 85
7 38 30 20 10 0
7,5 70
–
60 50 40 30 20 10
–
5
–
Flow Q, l/min
Head H, m
Type
Max suction head
Hu
m
Note:All rights to change or complete the data preserved. Obligatory data are given on special request.
HE
AD
The characteristics are valid for Hu=0 m, without resistance in the discharge pipe, for nominal voltage and up to 1000m above sea level.
STARTING VOLTAGE*static pressure in the pump housing at the starting instant.
UZ
FLOW
FLOW
FLOW
EF
FIC
IEN
CY
J/kg
700
600
500
400
300
200
100
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
0
10
9
8
7
6
5
4
3
2
1
0
HMAX
HMAX
QM
AX
A9-
A-8
A9-
A-8
A 9-A-8 A
9-A-8
A-8 M(T)
A-9 M(T)
3
Peripheral pumpsAQUAMAT
Measurement drawing, electrical characteristics and masses
Measurement drawing
A AA AB B BB C H
125 178,5 38 155 100 130 107 80 191 60
125 178,5 38 155 100 130 107 80 191 60
140 191 40 180 125 155 89 90 206 65
140 191 40 180 100 130 89 90 206 65
mm
Allowedno. of
startingper hour
Typepower*
* Output power of electric motor
OutputRated
P2
voltageU
kWV
HA
9
9
12
12
HE
190
190
211
211
R1
R1
R1
R1
D
1
1
1
1
/4
/4
/4
/4
"
"
"
"
335
335
392
362
Mass
16,0
14,0
21,5
16,5
kg
Dimensions, electrical characteristics and masses
Note:All rights to change or complete the data preserved. Obligatory data are given on special request.
Dischargeport
Port for watering
Su
ctio
np
ort
A1 H1 H2 L1
A-8 M 230 40
A-8 T 400 50
A-9 M 230 20
A-9 T 400 30
0,75
0,75
1,5
1,5
44
D
40B A
AAC
BB AB
L1 A1
H1
H2
HA
H
HE
D
20
96
20
10
4
Automatic pumpsHIDROPAK
Designation, design and technical data
Pump designation
8 M9 T
Basic type
Characteristic of pump size
Single-phase or three-phase motor
Application
Transported liquid
Automatic pumps HIDROPAK are applied for supplying
households, cottages, motels, farms with cold consumption water
and they also can be used for irrigation. They pump water out of
dug, drilled or driven wells with depth level up to 7,5 m. Pump with
injector can pump water out from a depth level up to 30 m.
Pump is used for transport of cold consumption water with
allowed quantity of sand max 25 g/m and the greatest diameter
of particles up to 0,04 mm.
3
Design
Pump is peripheral, single-stage in monoblock execution withelectric motor, pressure tank and pressure switch which enablesautomatic pump operation. Pressure gauge serves only forrunning control. There are standard executions withsingle-phase and three-phase asynchronous electric motors.
Materials of pump parts
Electric motor data
- Standard measures of connectors:suction: R 1 1/4"discharge: R 1"
- Two pole single-phase or three-phase asynchronous motor- Rated voltage: 1x230V, 50Hz or 3x400V, 50Hz- Degree of mechanical protection: IP54- Insulation class: F- Protection: pumps are delivered with motor without
protection, so it is necessary to carry out the protection withmotor protection switch
- Pump housing: gray iron- Motor housing: Al alloy- Shaft: stainless steel- Impeller: copper alloy
- Flow: up to 70 l/min- Head: up to 45 m- Working pressure range : 1-4,5 bar- Suction height: up to 30 m- Water temperature: up to 50 C
Technical data
o
Note:*Only for pumps with injector.
Standards and marks of quality
Pumps HIDROPAK are in category of domestic appliances. Theyhold all necessary certificates and declarations in accordancewith the directives of the European Union. According to the EUlegislation, they carry the CE sign.They are attested by TÜV Rheinland.Pumps meet the requirements of the following standards:- EN 60335-1- EN 60335-2-41- EN 55014-1- EN 55014-2
H - 9 T INJ 4"
Designation for injector*
up to
up to
5Installation
Automatic pumpsHIDROPAK
For water level depth up to 30 m and consumption upto 30 l/min, we recommend type H-9 M(T) INJ 4" (forlarger households, small motels, small farms, etc).
*When suction height is less then 30 m, pump can be placed on adistance more than 10 m from the well. Every decrease of suctionheight for 1 m allows increase of distance between pump andwell for 10 m, but not more than 50 m.
Pump installation in case of deep wells
Pumps are used for water level depth up to 7,5 m.For ground-floor or one-floor households, weekend houses, for water consumption up to 50 l/min, we recommend type H-8 M(T).For water consumption up to 70 l/min, we recommend type H-9 M(T), for larger households, small motels, etc.
NoteWhen distance between pump and well increases, suction height decreases for 1 m on every 10 m. This should be considered while determining the position of the pump.For very remote wells the pump has to be placed beside the well or an injector has to be used with increasing the diameter of the suction pipeline.
Pump installation in case of shallow wells
Note:All rights to change or complete the data preserved. Obligatory data are given on special request.
Suction pipefrom 1 / " (32mm)1
4
up to
Suction basketwith valve
"T" tap joint
Straight-troughtap
Well pipeSuction pipe 1 / " (32mm)1
4
Non return valve 1 / "1
4
Straight-troughtap
0,8
m
min
1,5
m
Main well pipe4" (100 mm)
Recirculating pipe1" (25 mm)
Suction pipe1 / " (32 mm)1
4
C
Pump characteristics for shallow wells
Pump characteristics with injector for deep wells
50 60
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
30 45 35 20 0 - - - - - - - - - - -
25 - 45 35 25 15 5 - - - - - - - - -
20 - - - 40 35 27 20 10 0 - - - - - -
15 - - - - 40 36 30 24 17 10 0 - - - -
10 - - - - - - 40 36 30 25 20 15 10 5 0
Flow Q, l/min
Head H, mHu
40 45 70 80
30 25 20 10 -
- 45 40 30 20 10
Head H, m
Flow Q, l/min
P2UMass
kWV
Type
Type
Type
6
Measurement drawing
Dimensions, electrical characteristics and masses
A
B
C
PUMP
Pressure gauge
Pressure switch
Port for watering
160
160
50
13
96
98
64
250
380
Rec
ircu
lati
ng
pipe
R1"
Su
ctio
npi
peR
1/
"1
4
R1 / "1
4
R1" DischargeportR
ecir
cula
tin
gpo
rt
Su
ctio
npo
rtR
1/
"1
4 R1"
46
50
725
240
Pump with
electric motor
INJECTORFOR 4" WELLS
powerOutputNominal
voltage
suction
height
Note:All rights to change or complete the data preserved. Obligatory data are given on special request.
1)QH data are valid for altitude up to 1000m above sea level. Pump characteristics for shallow wells are for a suction height Hu=0 m.
Measurement drawing and pump characteristics
Automatic pumpsHIDROPAK
0
H-8 M 0,75
0,75
230
H-8 T
1,1
1,1
400
H-9 M 230
H-9 T 400
A B C
H-9 T(M) INJ 4"
H-8 T(M)
H-9 T(M)
mm mm mm kg
390 490 540 26
390 490 540 26
400 500 550 28,5
400 500 550 26,5
a company of INDUSTRIES AGA-TEC
ATB Group - a global player
Company locations
Austria
Head office
ATB AUSTRIA ANTRIEBSTECHNIK AG
www.atb-motors.com
Germany
France
Hohenstaufengasse 7,
1010 Vienna
Phone: +43 1 90250-0
Fax: +43 1 90250-110
E-Mail: info atb-motors.com
ATB MOTORENWERKE GmbH
G.-Bauknecht-Straße 1,
A-8724 Spielberg
Phone: +43 3577 757-0
Fax: +43 3577 757-182
E-Mail: info at.atb-motors.com
ATB TECHNOLOGIES GmbH
Millennium Park 11,
A-6890 Lustenau
Phone: +43 5577 9010 - 0
Fax: +43 5577 9010 - 110
E-Mail: info at.atb-motors.com
ATB ANTRIEBSTECHNIK GmbH
Silcherstraße 74,
D-73642 Welzheim
Phone: +49 7182 14 - 1
Fax: +49 7182 14 - 590
E-Mail: info de.atb-motors.com
ATB MOTORENTECHNIK GmbH
Helgoländer Damm 75,
D-26954 Nordenham
Phone: +49 4731 365 0
Fax: +49 4731 365 159
E-Mail: nordenham de.atb-motors.com
ATB SELNI SAS
6 rue Louise Michel BP 24,
F-58028 Nevers Cedex
Phone: +33 3 86 93 42 00
Fax: +33 3 86 93 42 22
E-Mail: info fr.atb-motors.com
@
Http://
@
@
@
@
@
Great Britain
Serbia
Czech Republic
China
ATB MORLEY Ltd.Bradford Road, West Yorkshire,
Phone: +44 113 257 1734Fax: +44 113 257 0751E-Mail: sales uk.atb-motors.com
ATB LAURENCE SCOTT LTD.PO Box 25 Hardy Road,
,Phone: +44 1603 628 333Fax: +44 1603 619 788E-Mail: admin laurence-scott.com
ATB SEVER a.d.Magnetna polja 6,
Phone: +381 24 548 111, 548 222Fax: +381 24 546 893E-Mail: sever yu.atb-motors.com
ATB COMPONENTS S.R.O.Lihovarská 1335/9,CZ-71610 Ostrava - RadvanicePhone: +420 5 962 333 40Fax: +420 5 962 333 40E-Mail: atb.bastro quick.cz
ATB MOTORS (SHANGHAI) Co. Ltd., Building 28,
No.500 East Fute 2nd Road,200131 ShanghaiPhone: +86 21 5046 1928Fax: +86 21 5046 3362E-Mail: info cn.atb-motors.com
LS28 6QA Leeds
NR1 1JD Norwich Norfolk
24000 Subotica
Section E, Floor 1
@
@
@
@
@
ATB SEVER a.d.
Magnetna polja 6
24 000 Subotica
Serbia
Tel. +381 24 548-111, 548-222
Fax +381 24 546-893
www.atb-motors.com
sever yu.@ atb-motors.com
Top Related