Perfection Home Inspections1042 E. Fairbrook Circle
Mesa, AZ 85203602-524-2916
perfectionhomeinspections.com
Webb, Roy & Joan35900 S. Gold Rock Circle
Inspected 2/4/17 9:00 AMBuilt 20085692 sf
Greg Oswalt Arizona Lic. 38752
Wickenburg, AZ 85390
Client Information:
Inspected By:
Record Number 7124
Printed Saturday, February 4, 2017
John L. PayneUnited Country Excelerate Real Estate &Auction
Referral Information
FRONT VIEW OF HOME PHOTO
Page 1 of 39
Inspection SummaryPerfection Home Inspections
1042 E. Fairbrook CircleMesa, AZ 85203602-524-2916
perfectionhomeinspections.com
Safety ConcernEXTERIOROutside Outlets
The polarity and the grounding of all accessible exterior outlets were tested.The exterior outlet in the back of the garage below the sprinkler timer is not GFCI protected.GFCI outlets recommended for all exterior outlet to prevent shocks.
GROUNDSHand Rail
No handrail installed for back steps. This is a trip hazard. Recommend installing a handrail for all steps. See pictureGARAGE/CARPORTAuto Garage Door Lift Controls
The automatic garage door opener did not stop and return the garage door when meeting obstacles. According toreports received by the U.S. Consumer Product Safety Commission (CPSC), approximately 60 children between theages of 2 and 14 have been trapped and killed under automatic garage doors between March 1982 and 1997. Irecommend all automatic garage doors openers stop and reverse when meeting obstacles to prevent someone orsomething from being smashed by the automatic door. Adjusting the automatic door opener to open and close withthe proper tension normally requires turning a screw or nut on the opener. In this case less force is needed to closethe door. All garage door openers manufactured after January 1, 1993 are required to have this auto- reversefunction. Recommend a qualified contractor evaluate and make all necessary repairs. A 2x4 block 1.5" high wasplaced on the garage floor under the door to test the automatic stop and reverse function of this garage door opener. The garage doors opener on both ends of the garage are holding down and did not automatically reverse and goback up.Recommend a qualified contractor evaluate and make all necessary repairs.
PLUMBINGCross Connections
Hoes bibb on the west side of the house at the water main has no vacuum breaker installed.To avoid a cross connection that may pollute potable drinking water recommend a vacuum breaker device beinstalled on all hose bibbs. This may not have been required when it was built but it is now considered unsafe. Thisis an inexpensive part that can be purchased at a local hardware store and attached to the hose bibbs.
Well Pump TypeWell is in the front near the neighbor to the west.The electric panel at this well is missing knockouts in the breaker panel cover. Recommend installing knockouts.
POOLAutomatic Safety Controls
No temperature pressure relief valve pipe found for the pool heater. Recommend all temperature pressure reliefvalve pipes be within 12 inches of the ground and pointed straight down.Recommend a qualified contractor evaluate and make all necessary repairs
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
1Summary: Page of 3 Perfection Home InspectionsPage 2 of 39
Service/RepairEXTERIORWall Covering \ Cladding
There are some cracked in the stucco on the east side by the window near the front. Recommend patching thesecracks. Cracks in stucco are mostly cosmetic and rather common in the phoenix area but they should be monitored andpatched when convenient or immediately when any sign of a leak develops. Recommend patching all stucco cracksand holes 1/16 of an inch or larger as soon as they are found. The stucco is too close to the ground in some areas. Recommend a minimum of a 4 inch gap between the bottom of the stucco and the finished grade and a minimum of2 inches above the cement. Stucco need to be able to drain moisture out of the walls through the bottom of thestucco and termites and other pests may enter the home undetected if this distance is not maintained.
GROUNDSGROUNDS
The fountain in the back is not working.Recommend a qualified contractor evaluate and make all necessary repairs.
Retaining WallNo weep holes found in the retaining wall in the back. It supports approximately 3' of soil.Recommend a qualified contractor evaluate and make all necessary repairs.
ROOFROOF
Debris on the roof should be removed. Debris can cause water to backup on the roof and create a roof leak.Porch Roof
On west side patio roof at the north has some small cracks on the roof surface.Recommend a qualified contractor evaluate and make all necessary repairs.
GARAGE/CARPORTGarage Overhead Door Spring
The east side garage door spring needs adjustment. When disconnected from the opener the overhead door slamsto the ground. This is a safety problem.Recommend a qualified contractor evaluate and make all necessary repair
ATTICAttic Access
No access to the attic. Can not check attic for electrical, insulation, plumbing or roof leaks. Recommend inspectingattic after proper access is provided.
COOLING Air Handler(s)
The air handlers on installed in exterior closets on the east and west side of the house. The east side air handlerstorage room door has not hole for the bottom door latch to enter.Recommend a qualified contractor evaluate and make all necessary repairs.
MBEDFloor
Some scratches in the wood flooring in the master bedroom.Recommend a qualified contractor evaluate and make all necessary repairs.
POOLAuto Sweep\Self Cleaning
Pool pop ups needed to clean the pool did not work when tested. Recommend service by a qualified swimming poolcompany or contractor.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
2Summary: Page of 3 Perfection Home InspectionsPage 3 of 39
Recommend Further InvestigationW. HEATERWATER HEATER
The east side water heater is totally covered so I cannot get any information on this water heater other than testedthe faucets for hot water.The listed information is mostly related to the west side water heater that is not covered.
LAUNDRYAppliances
The dryer was tested without cloths inside to find out if it heats up when turned on. This dryer did not heat up whentested. Recommend further investigation. The washing machine was tested by turning it on with no cloths inside. This test is only to find out if water enters andleaves the washer with out any signs of leaks.
OtherStains on the base of the laundry sink cabinet but no signs of a leak. Something may have spilled under the sink inthis area.Recommend monitoring area for leaks.
MBATHJacuzzi Bath or Tub
Tub overflow drains are not tested during a home inspection because they tend to leak. Recommend not filling a tubto the overflow because this may cause a leak. No access panel found so the pipes, motor, ground wire, GFCI breaker and other parts of the Jacuzzi tub could notbe inspected. Recommend seller provide access panel for Jacuzzi so this area can be inspected.
Monitor/MaintainW. HEATEROverflow Pan
Recommend installing an overflow pan under the water heater and installing a drain line from this pan if possible tothe exterior.
MBATHToilet Bowl and Tank
Bidet also installed and tested.Tub/Shower Faucet
This shower is electronically controlled so I only operated the upper most shower head on the wall. Recommendfinding the instruction manual to learn how to operate this shower.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
3Summary: Page of 3 Perfection Home InspectionsPage 4 of 39
Inspection Report Details
GENERAL INFORMATIONSatisfactory BuyerGENERAL INFORMATION - Buyer
You have the right to ask for repairs and to have other problems addressed even if they are not included in thisinspection report. Paint and carpet are generally not included in this report. The washing machine, dryer andrefrigerator may not be tested unless specifically requested. The Agreement for Visual Inspection and pictures are anintegral part of this report, please refer to the Agreement for limitations regarding this report. Pictures are provided togive a better idea of the conditions reported on and I recommend repair people get a copy of the pictures provided for abetter understanding of the problems needing repair. Roofs often contain hidden defects and if that is a concern, aroofer should be brought in prior to the close of escrow to determine such defects. This report is not to be consideredcomplete without consulting with the inspector that created it. Please read the entire report carefully before makingdecisions based on this report.Recommend the buyer have all exterior door locks re-keyed to replaced after taking possession. All Accessibleentryway doors are inspected. HOME WARRANTY COMPANIES will not repair AC units if the units have not beenproperly maintained. Recommend annual service of AC units and recommend making sure AC coils and filter are cleanbefore calling a warranty company for repairs. If water leaks or water stains are listed in this report there is always apossibility of a mold problem with such problems. If mold is a concern recommend having a qualified contractor checkfor mold. Make all necessary repairs means to repair or replace making all necessary corrections to solve the problemand correct all damages created by the problem as recommend by the qualified contractor evaluating the problem. ToWhom Report Made: Client is the only person to whom the Inspection Report and examination is made and to no otherperson or entity. Inspection Report may not be circulated to any other person or entity for material use other than theClient or it shall become void. All examinations and reports covered by this agreement are void to all others than Client.
Satisfactory OccupiedOccupancy - OccupiedOccupied homes cannot be inspected as well as vacant homes due to personal belongings unintentionally covering upor hiding existing problems. I recommend a through inspection after all personal belongings are removed.
Satisfactory Single Family HomeInspection Type - Single Family HomeFor all damage found recommend first locating and solving the problem that caused the damage prior to repairingexisting damage, and have all problems found be corrected by qualified professionals in a professional manor. Aqualified contractor or professional is one with a state issued license competent in their field of expertise regarding theissues addressed and with insurance covering their work. This report is not to be considered complete without consulting with the inspector that created it. Please read the entirereport carefully before making decisions based on this report.Appears acceptable means of the items observed no visual defects other than normal wear for their age were noticedduring the inspection. Monitor means to observe the item on a regular basis to check for a change in the condition of the item.
EXTERIORSatisfactory Masonry One StoryType of Wall Structure - Masonry One Story
Satisfactory Appears LevelWall Structure - Appears Level
Satisfactory WoodType of Columns - Wood
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
1Inspection Details: Page of 35 Perfection Home InspectionsPage 5 of 39
EXTERIORStucco\Synthetic Stucco, Stucco To SoilService/Repair Wall Covering \ Cladding - Stucco\Synthetic Stucco, Stucco To Soil
There are some cracked in the stucco on the east side by thewindow near the front. Recommend patching these cracks. Cracks in stucco are mostly cosmetic and rather common in thephoenix area but they should be monitored and patched whenconvenient or immediately when any sign of a leak develops. Recommend patching all stucco cracks and holes 1/16 of an inch orlarger as soon as they are found. The stucco is too close to the ground in some areas. Recommend a minimum of a 4 inch gap between the bottom of thestucco and the finished grade and a minimum of 2 inches above thecement. Stucco need to be able to drain moisture out of the wallsthrough the bottom of the stucco and termites and other pests mayenter the home undetected if this distance is not maintained.
Satisfactory InspectedExterior Electrical Fixtures - Inspected
TestedSafety Concern Outside Outlets - TestedThe polarity and the grounding of all accessible exterior outlets were tested.The exterior outlet in the back of the garage below the sprinkler timer is not GFCI protected.GFCI outlets recommended for all exterior outlet to prevent shocks.
Satisfactory None Soffit\Eaves\Fascia - None
Satisfactory StuccoFlashings and Trim - Stucco
Satisfactory Poured ConcreteExposed Foundation - Poured Concrete
Satisfactory TestedExterior Doors - TestedExterior entrance door tested and found to be in proper working order.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
2Inspection Details: Page of 35 Perfection Home InspectionsPage 6 of 39
EXTERIORSatisfactory SlidingPatio Doors - Sliding
Exterior patio and or back door(s) tested and found to be in proper working order. Safety glass installed.
Satisfactory AdequateGrading\Surface Drainage - AdequateRecommend all soil be sloped away from house at all times to improve drainage and protect the foundation andrecommend installing roof gutters to help keep rain water away from the foundation.When water is allowed to flow towards the foundation due to improperly slopped soil foundation problems may develop.
Satisfactory InspectedDrainage Property - Inspected
Satisfactory CheckedVegetation - Checked
Satisfactory WoodWindow Character Material - Wood
Satisfactory CasementWindow Character Type - Casement
Satisfactory Duel PaneGlass - Duel Pane
Satisfactory Tested OKDoor Bell - Tested OK
Satisfactory No BasementBasement - No Basement
Satisfactory NoneRaised Foundation - None
Satisfactory OtherStorage Room - OtherSample picture of the exterior storage room and corral area. Lightsand outlets tested.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
3Inspection Details: Page of 35 Perfection Home InspectionsPage 7 of 39
GROUNDSGeneral CommentService/Repair GROUNDS - General Comment
The fountain in the back is not working.Recommend a qualified contractor evaluate and make all necessary repairs.
Satisfactory GravelDriveway - Gravel
Satisfactory ConcreteWalkways - Concrete
Satisfactory InspectedOutside Steps - Inspected
No Exterior Hand RailsSafety Concern Hand Rail - No Exterior Hand RailsNo handrail installed for back steps. This is a trip hazard. Recommend installing a handrail for all steps. See picture
Satisfactory Guard Rails 36 inches or HigherBalconies - Guard Rails 36 inches or Higher
Satisfactory ConcretePatio - Concrete
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
4Inspection Details: Page of 35 Perfection Home InspectionsPage 8 of 39
GROUNDSSatisfactory ConcretePorches - Concrete
Satisfactory NoneWood Decks - None
OtherService/Repair Retaining Wall - OtherNo weep holes found in the retaining wall in the back. It supports approximately 3' of soil.Recommend a qualified contractor evaluate and make all necessary repairs.
Satisfactory No Problems FoundStoops / Areaways - No Problems Found
ROOFDebrisService/Repair ROOF - Debris
Debris on the roof should be removed. Debris can cause water tobackup on the roof and create a roof leak.
Satisfactory Walked on RoofHow Inspected - Walked on Roof
Satisfactory Built Up\FoamRoof Covering - Built Up\Foam
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
5Inspection Details: Page of 35 Perfection Home InspectionsPage 9 of 39
ROOFSatisfactory FlatRoof Style - Flat
Some sample pictures of the roof.
Satisfactory Not VisibleFlashing - Not Visible
Satisfactory NoneValleys - None
Satisfactory ABSPlumbing Vents - ABS
Satisfactory ScuppersGutter/Drainage System - ScuppersRoof scuppers metal flanges tend to pop loose in 10 to 12 years after installation and need to be resealed. Recommenda qualified contractor evaluate and make all necessary repairs.
Satisfactory FlatGarage / Carport Roof - Flat
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
6Inspection Details: Page of 35 Perfection Home InspectionsPage 10 of 39
ROOFSame as HouseService/Repair Porch Roof - Same as House
On west side patio roof at the north has some small cracks on theroof surface.Recommend a qualified contractor evaluate and make all necessaryrepairs.
Satisfactory InstalledSkylight - Installed
Satisfactory Sky Light(s), Solar PanelOther Roof Penetrations - Sky Light(s), Solar Panel
GARAGE/CARPORTSatisfactory Multi Car DetachedGarage Type - Multi Car Detached
Three car detached garage.Satisfactory InspectedGarage Exterior Walls - Inspected
Satisfactory ConcreteGarage Floor - Concrete
Satisfactory NoneGarage Door To House - NoneThere is no door from the garage directly to the home.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
7Inspection Details: Page of 35 Perfection Home InspectionsPage 11 of 39
GARAGE/CARPORTSatisfactory TestedGFCI Outlets - Tested
The polarity and the grounding of all accessible exterior outlets were tested.Satisfactory Tested, OtherLight Fixture - Tested, Other
Skylights.Improper AdjustmentService/Repair Garage Overhead Door Spring - Improper Adjustment
The east side garage door spring needs adjustment. When disconnected from the opener the overhead door slams tothe ground. This is a safety problem.Recommend a qualified contractor evaluate and make all necessary repair
Auto Stop\ Reverse DefectiveSafety Concern Auto Garage Door Lift Controls - Auto Stop\ Reverse DefectiveThe automatic garage door opener did not stop and return thegarage door when meeting obstacles. According to reports receivedby the U.S. Consumer Product Safety Commission (CPSC),approximately 60 children between the ages of 2 and 14 have beentrapped and killed under automatic garage doors between March1982 and 1997. I recommend all automatic garage doors openersstop and reverse when meeting obstacles to prevent someone orsomething from being smashed by the automatic door. Adjustingthe automatic door opener to open and close with the proper tensionnormally requires turning a screw or nut on the opener. In this caseless force is needed to close the door. All garage door openersmanufactured after January 1, 1993 are required to have this auto-reverse function. Recommend a qualified contractor evaluate andmake all necessary repairs. A 2x4 block 1.5" high was placed onthe garage floor under the door to test the automatic stop andreverse function of this garage door opener. The garage doorsopener on both ends of the garage are holding down and did notautomatically reverse and go back up.Recommend a qualified contractor evaluate and make all necessaryrepairs.
Satisfactory 4 to 6 Inches Above FloorGarage Electronic Eye - 4 to 6 Inches Above Floor
Satisfactory FlatGarage Roof Framing Style - Flat
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
8Inspection Details: Page of 35 Perfection Home InspectionsPage 12 of 39
GARAGE/CARPORTSatisfactory NoneGarage Fascia\Soffit - None
Satisfactory ScuppersGarage Gutters - Scuppers
Satisfactory Drywall\PlasterGarage Interior Walls - Drywall\Plaster
Satisfactory Drywall\PlasterGarage Interior Ceiling - Drywall\Plaster
Satisfactory OverheadGarage Doors - Overhead
Satisfactory TestedGarage Man Door Exterior - TestedGarage door to side yard tested and found to be in proper working order.
Satisfactory In Door OnlyGarage Windows - In Door OnlyWindows are only in the overhead garage doors.
Satisfactory TrussGarage Roof Framing Type - Truss
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
9Inspection Details: Page of 35 Perfection Home InspectionsPage 13 of 39
GARAGE/CARPORTSatisfactory Fiberglass BattCeiling Insulation - Fiberglass Batt
Satisfactory **None LocatedInsulation & Vapor Retarder - **None Located
W. HEATERTestedRecommend
FurtherInvestigation
WATER HEATER - Tested
The east side water heater is totally covered so I cannot get anyinformation on this water heater other than tested the faucets for hotwater.The listed information is mostly related to the west side water heaterthat is not covered.
Satisfactory Bradford WhiteWater Heater 1 Mfg. - Bradford White
Satisfactory 4500Water Heater 1 Rated BTU/Watts - 45004500 Watts.
Satisfactory Water Heater CapacityWater Heater 1 Size in Gallons - Water Heater CapacityThe water heater has a BTU/hour rating of 80 gallons.
Satisfactory ExtStore RoomWater Heater 1 Location - ExtStore RoomThe water heater is located in an exterior store room\closet on the west side.
Satisfactory Electric, SolarWater Heater Fuel - Electric, SolarThe west side water heater is electric and it has a solar panel on the roof to assist in heating of the water. The east sidewater heater is electric and has tubes run through the roof for a future solar heater.
Satisfactory PresentTemp. Pres Relief Valve and Pipe - Present
Satisfactory No Problems FoundAutomatic Safety Controls - No Problems Found
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
10Inspection Details: Page of 35 Perfection Home InspectionsPage 14 of 39
W. HEATERSatisfactory InspectedWater Heater Nipples - Inspected
Satisfactory PresentWater shutoff Valve - Present
Satisfactory InspectedWater Heater Exterior Jacket - Inspected
Satisfactory InspectedGround Wire - Inspected
NoneMonitor/Maintain Overflow Pan - NoneRecommend installing an overflow pan under the water heater and installing a drain line from this pan if possible to theexterior.
LAUNDRYSatisfactory TestedDoor - Tested
Satisfactory Drywall/PlasterWalls & Ceiling - Drywall/Plaster
Satisfactory Power attic ventVentilation - Power attic vent
Satisfactory Not VisibleDryer Vented - Not Visible
Satisfactory Gate TypeWasher Faucets - Gate Type
Satisfactory Not VisibleWasher Drains - Not Visible
Satisfactory 220 ElectricLaundry Energy Source - 220 Electric
Dryer Tested, Washing Machine TestedRecommendFurtherInvestigation
Appliances - Dryer Tested, Washing Machine Tested
The dryer was tested without cloths inside to find out if it heats up when turned on. This dryer did not heat up whentested. Recommend further investigation. The washing machine was tested by turning it on with no cloths inside. This test is only to find out if water enters andleaves the washer with out any signs of leaks.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
11Inspection Details: Page of 35 Perfection Home InspectionsPage 15 of 39
LAUNDRYSatisfactory TileFloor - Tile
Satisfactory TestedLight Fixture - Tested
Satisfactory TestedOutlets - TestedAll accessible outlets were tested in the laundry.
Satisfactory CentralHeating and Cooling Source - Central
Satisfactory TestedLaundry Sink - Tested
Satisfactory TestedLaundry Sink Faucets - Tested
Satisfactory TestedLaundry Sink Drain Trap - Tested
CabinetsRecommendFurtherInvestigation
Other - Cabinets
Stains on the base of the laundry sink cabinet but no signs of a leak.Something may have spilled under the sink in this area.Recommend monitoring area for leaks.
ATTICNo AccessService/Repair Attic Access - No Access
No access to the attic. Can not check attic for electrical, insulation, plumbing or roof leaks. Recommend inspecting atticafter proper access is provided.
CHIMNEYSatisfactory Metal BoxFireplace1 - Metal Box
Metal box electric heat fire places in the living room, the entry and the large room in the back on the east side.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
12Inspection Details: Page of 35 Perfection Home InspectionsPage 16 of 39
CHIMNEYSatisfactory MetalChimney 1 Type - Metal
Satisfactory MetalFlue Lining - Metal
Satisfactory OtherSpark Arrestor - OtherThese fireplaces do not vent to the exterior they are electric.
Satisfactory Fireplace Screen/DoorFire Proofing - Fireplace Screen/Door
COOLING Satisfactory TestedCOOLING SYSTEM - Tested
Central cooling system(s) tested using normal operating controls. Dust and other contaminants usually find there way into all heatingand cooling duct systems.For all used homes to help protect your health and for better airquality I recommend before moving in or soon thereafter a thoroughcleaning of the entire heating and cooling duct system by a qualifiedprofessional. For all AC repairs and service I recommend PremierAir Solutions Inc. for AC work. 480-940-2351The Federal appliance manufacturing standards (10 CFR 430) willrequire all residential-sized central air conditioners and heat pumps,manufactured or imported on or after January 23, 2006 to meet anew higher SEER standard. AC units that do not meet these newstandards will need to be replaced with AC units up to 50% larger insize when they break and parts may be hard to find for Lower SEERunits.AC units have an average life of 12 to 15 years in the Phoenix area.
Satisfactory 5-TonEstimated AC Size - 5-TonModel Number: 60Compressor RLA: Two similar 5 ton Trane AC units.Estimated Size: 5 TonRecommended Size: 1 Ton for every 450 Sq feet of living space. However the actual required size of unit for a homecan only be properly determined by using performing a heat load calculation on the home.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
13Inspection Details: Page of 35 Perfection Home InspectionsPage 17 of 39
COOLING Satisfactory TraneCooling System(s) - Trane
Cooling coil(s) made by Trane.Satisfactory ElectricEnergy Source - Electric
Satisfactory Checked BreakerCooling System Electrical - Checked BreakerBreaker Used 60 & 60Maximum Breaker Size 60 & 60
Satisfactory InstalledQuick Disconnect - Installed
Satisfactory AdjustableRegisters - Adjustable
Satisfactory CleanAir Filters and Dampers - CleanAir filter system installed at the air handlers in the exterior closets one on the east side and one on the west side.
Satisfactory Not VisibleDuct Type - Not Visible
Satisfactory Air to AirHeat Pump - Air to AirBoth heating and cooling systems are heat pump and heat pumps use the same heating and cooling duct system, thesame air filter, the same coils, air handler and the same thermostat for heating and cooling.
Satisfactory ExteriorCooling System Coils - ExteriorThe AC cooling coils are located outside one on the east side and the other on the west side of the home.
OtherService/Repair Air Handler(s) - OtherThe air handlers on installed in exterior closets on the east and west side of the house. The east side air handler storageroom door has not hole for the bottom door latch to enter.Recommend a qualified contractor evaluate and make all necessary repairs.
Satisfactory InstalledCondensate Drain - Installed
Satisfactory DetailsDifferential Temperature(s) - DetailsA differential temperature between 20 and 30 degrees is considered good for a air conditioning system. Over 30 the unitmay have a clogged filter or other problem which may cause the unit to ice up. For a split of 16 degrees and lower andfor units with a split of 30 degrees and higher I recommend the AC unit be serviced.Unit one has a 25 degree split.Unit two has a 23 degree split
Satisfactory NoneEvaporative Cooler - None
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
14Inspection Details: Page of 35 Perfection Home InspectionsPage 18 of 39
FURNACESatisfactory TestedFURNACE - Tested
Central heating system(s) tested using normal operating controls. Visually observed automatic safety controls wereinspected and found to be in proper working order.
Satisfactory Heat PumpFurnace Type - Heat PumpThe central heating and cooling systems are heat pumps and heat pumps uses the same heating and cooling ductsystem, the same air filter, the same coils, air handler and the same thermostat for heating and cooling. Some heatpumps have an electric back-up heater installed.
Satisfactory Single and MultiThermostat - Single and Multi
Satisfactory Central FilterFilter System For Central AC & Heat - Central FilterThe central heating system use the same filter(s) and duct system for the heating system as is used for the AC system.
Satisfactory Not VisibleDistribution System For Central AC and Heating Sys - Not Visible
Satisfactory TraneForced Air System Mfg(s). - TraneHeater made by Trane.
Satisfactory ElectricForced Air Sys. Energy Source - Electric
Satisfactory InspectedAutomatic Safety Controls - Inspected
KITCHENSatisfactory TestedMicrowave - Tested
Satisfactory Hood ExhaustExhaust Fan Hood - Hood Exhaust
Satisfactory InspectedKitchen Ceiling and Walls - Inspected
Satisfactory TileKitchen Floors - Tile
Satisfactory CentralHeating and Cooling Source - Central
Satisfactory InspectedKitchen Cabinets - Inspected
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
15Inspection Details: Page of 35 Perfection Home InspectionsPage 19 of 39
KITCHENSatisfactory StoneCounter top - Stone
Satisfactory InspectedKitchen Sink - InspectedTwo sinks and two disposals. x
Satisfactory TestedKitchen Sink Faucet - Tested
Satisfactory InspectedWater Supply - Inspected
Satisfactory TestedKitchen Drain and Trap - Tested
Satisfactory Recessed Can, SkylightKitchen Switches Fixtures - Recessed Can, SkylightRecessed light fixtures require special light bulbs designed to reflect the heat away from the fixture. Using improperbulbs may damage the fixtures and start fires. Recommend checking all light bulbs in recessed fixtures to make surethey are acceptable for the fixture.
Satisfactory GFCI ProtectedKitchen Wall Receptacles - GFCI ProtectedKitchen counter receptacles within 6 feet of a water source are GFCI protected. Starting in 1996 some buildingdepartments started requiring all receptacles serving kitchen counter tops to have GFCI protection.
Satisfactory TestedGarbage Disposal - Tested
Satisfactory TestedDishwasher - Tested
Satisfactory TestedKitchen Windows - Tested
Satisfactory ElectricRange Oven - ElectricThe self cleaning function, timers and clocks of ovens are not tested as part of the home inspection.
Satisfactory ElectricSurface Cook top - Electric
Satisfactory NoneReverse Osmosis/Water Filter - None
Satisfactory NoneTrash Compactor - None
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
16Inspection Details: Page of 35 Perfection Home InspectionsPage 20 of 39
INTERIORSatisfactory Concrete SlabFloor Structure - Concrete Slab
The slab inspection is visual only and carpets are not lifted to inspect slabs. Slabs may have cracks and other problemnot detectable by a visual home inspection. No defects in the slab were found at the time of the home inspection.
Satisfactory InspectedInterior Walls and Ceiling - Inspected
Satisfactory InspectedInterior Floor Covering - Inspected
Satisfactory All Habitable RoomsRooms With Heat Source - All Habitable Rooms
Satisfactory All Habitable RoomsRooms With Cooling Source - All Habitable Rooms
Satisfactory One or More TestedSmoke Detectors - One or More TestedThe smoke alarm(s) was tested by pushing the button on the unit. They were not smoke tested. Photoelectric smokealarms are superior to Ionization smoke alarms. Under UL testing ionization smoke alarms fail 20% of the time and 97%of false alarms are from ionization type smoke alarms. All smoke alarms should be replaced every 10 years or less.
Satisfactory TestedWindows - Tested
Satisfactory Sample Number TestSwitches and Light Fixtures - Sample Number Test
Satisfactory Three Prong GroundedInterior Outlets - Three Prong GroundedThe polarity and the grounding of all accessible exterior outlets were tested.
Satisfactory Tested, ResetGFCI - Tested, ResetAll accessible GFCI outlets were tested and reset.
Satisfactory None observedSigns of Water Penetration - None observedNo water penetration found inside house.
Satisfactory None VisibleInsulation Walls - None Visible
Satisfactory Living RoomInterior Rooms - Living Room
Satisfactory NoneSkylight - None
Satisfactory NoneVisible Flues and Dampers - None
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
17Inspection Details: Page of 35 Perfection Home InspectionsPage 21 of 39
INTERIORSatisfactory NoneStairways and Steps - None
Satisfactory NoneBalconies and Railings - None
ELECTRICSatisfactory Underground ServiceMain Electrical Service - Underground Service
The main electrical service entrance conductors are not visible and therefore were not visually observed. No signed ofdefected were found regarding these conductors.
Satisfactory Front of HouseMain Elect. Panel Location - Front of House
Satisfactory In Back, FrontMain Electrical Disconnect - In Back, FrontThe main shut off breaker is located outside in the main electric panel on the front of the house. The main shut off breaker is located outside in the main electric panel on the back of the house.
Satisfactory InspectedMain Electric Panel - Inspected
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
18Inspection Details: Page of 35 Perfection Home InspectionsPage 22 of 39
ELECTRICSatisfactory 15 and 20 amp, 30 amp, 50 amp, 60 ampBreakers & Wire Sizes - 15 and 20 amp, 30 amp, 50 amp, 60 amp
Satisfactory None ObservedCompatibility Issues - None Observed
Satisfactory Not VisibleMain electric Wire Type - Not Visible
Satisfactory Not VisibleMain Service Wire Size - Not Visible
Satisfactory 400Main Panel Amp. Rating - 400
Satisfactory 110 / 220Voltage Available - 110 / 220
Satisfactory Recommend GFCIGFCI Outlets Tested - Recommend GFCITo prevent electrical shocks we recommend providing GFCI protection for all exterior and garage outlets and also on allinterior outlets within six feet of a water source such as a sink, or tub. When a home is remodeled GFCI outlets arenormally required. GFCI outlets may not have been required at the time of construction but are recommended forsafety.
Satisfactory Water Pipe, Driven RodGrounding - Water Pipe, Driven Rod
Satisfactory Water MainBonding - Water Main
Satisfactory NoneAluminum Branch Wiring - NoneNo solid strand aluminum wiring to branch circuits found.
Satisfactory RomexType of House Wire - Romex
Satisfactory CopperInterior House Wiring - Copper
Satisfactory 3 SlottedElectrical Outlets - 3 Slotted
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
19Inspection Details: Page of 35 Perfection Home InspectionsPage 23 of 39
ELECTRICSatisfactory Other*Sub Panel Locations - Other
Sub electric panels in the garage, at the pool equipment area, in thelaundry and in the game room.
PLUMBINGSatisfactory Side of HouseMain Water Shut Off - Side of House
The main water shut off valve is located on the side of the west house.Satisfactory Ball Valve TestMain Water Shutoff Test - Ball Valve Test
Satisfactory CopperMain Supply Type - CopperCopper line at the house but may not be copper.
Satisfactory 40 to 80 PSIWater Pressure - 40 to 80 PSIWater pressure recorded today was 40 psi. Recommended water pressure between 40 to 80 PSI.
Satisfactory AverageFunctional Water Flow - Average
Satisfactory AverageFunctional Drainage - Average
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
20Inspection Details: Page of 35 Perfection Home InspectionsPage 24 of 39
PLUMBINGSatisfactory TestedHose Bibs Tested - Tested
Tested all accessible exterior hose bibbs for water flow and leaks.Satisfactory CopperInterior Visible Water Pipes - Copper
All visible interior pipes are copper but some pipes hidden in the attic and in the walls may not be copper. Recommendasking seller what types of pipes have been used.
Satisfactory ABSInterior Waste/Vent Pipes - ABS
Satisfactory None FoundWater Leaks Supply/Drain - None Found
Hose BibbSafety Concern Cross Connections - Hose BibbHoes bibb on the west side of the house at the water main has no vacuum breaker installed.To avoid a cross connection that may pollute potable drinking water recommend a vacuum breaker device be installedon all hose bibbs. This may not have been required when it was built but it is now considered unsafe. This is aninexpensive part that can be purchased at a local hardware store and attached to the hose bibbs.
Satisfactory None FoundEjector Pump Location - None Found
Satisfactory OtherFuel Supply Tank Type - OtherGas propane tank in the back for heating the spa.
Satisfactory InspectedFuel Supply Piping & Supports - Inspected
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
21Inspection Details: Page of 35 Perfection Home InspectionsPage 25 of 39
PLUMBINGOtherSafety Concern Well Pump Type - Other
Well is in the front near the neighbor to the west.The electric panel at this well is missing knockouts in the breakerpanel cover. Recommend installing knockouts.
Satisfactory No Visible ProblemsPlumbing Pipe Support and Insulation - No Visible Problems
Satisfactory None FoundWater Softener - None Found
MBATHSatisfactory Door Lock and HardwareDoor - Door Lock and Hardware
Satisfactory DoubleSink - Double
Satisfactory InspectedSink Cabinet - Inspected
Satisfactory TestedSink Faucet - Tested
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
22Inspection Details: Page of 35 Perfection Home InspectionsPage 26 of 39
MBATHSatisfactory TestedDrain, Trap, Waste and Vent Piping - Tested
Satisfactory Wall, Ceiling, SkylightSwitches and Fixtures - Wall, Ceiling, Skylight
Satisfactory GFCIReceptacles - GFCI
Satisfactory InspectedWalls and Ceiling - Inspected
Satisfactory Natural Stone TileFloor Covering - Natural Stone Tile
Satisfactory Electic Fan, WindowVentilation - Electic Fan, Window
Satisfactory Central Heating & CoolingHeating and Cooling - Central Heating & Cooling
Flushes, Drains, and RefillsMonitor/Maintain Toilet Bowl and Tank - Flushes, Drains, and RefillsBidet also installed and tested.
Adequate FlowMonitor/Maintain Tub/Shower Faucet - Adequate FlowThis shower is electronically controlled so I only operated the upper most shower head on the wall. Recommend findingthe instruction manual to learn how to operate this shower.
Satisfactory TestedTub/Shower Drain - Tested
Satisfactory Natural Stone TileTub/Shower Enclosure - Natural Stone Tile
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
23Inspection Details: Page of 35 Perfection Home InspectionsPage 27 of 39
MBATHTub Faucet & Drain Tested, No access panelRecommend
FurtherInvestigation
Jacuzzi Bath or Tub - Tub Faucet & Drain Tested, No access panel
Tub overflow drains are not tested during a home inspectionbecause they tend to leak. Recommend not filling a tub to theoverflow because this may cause a leak. No access panel found so the pipes, motor, ground wire, GFCIbreaker and other parts of the Jacuzzi tub could not be inspected. Recommend seller provide access panel for Jacuzzi so this areacan be inspected.
MBEDSatisfactory Door(s), Light, PoleCloset - Door(s), Light, Pole
Satisfactory Hardware CheckedDoor - Hardware Checked
Satisfactory InstalledLight Fixture - Installed
Satisfactory 3 Prong GroundedOutlets - 3 Prong Grounded
Satisfactory InspectedWalls and Ceiling - Inspected
Wood/Imitation WoodService/Repair Floor - Wood/Imitation WoodSome scratches in the wood flooring in the master bedroom.Recommend a qualified contractor evaluate and make all necessaryrepairs.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
24Inspection Details: Page of 35 Perfection Home InspectionsPage 28 of 39
MBEDSatisfactory Central Heating and CoolingHeating & Cooling Source - Central Heating and Cooling
Satisfactory Approx. 44" or Less to Sill, DoorWindows - Approx. 44" or Less to Sill, Door
BATH2Satisfactory LocatedBATH2 - Located
This bathroom is located in the front bedroom.Satisfactory Door Lock and HardwareDoor - Door Lock and Hardware
Satisfactory DoubleSink - Double
Satisfactory InspectedSink Cabinet - Inspected
Satisfactory TestedSink Faucets - Tested
Satisfactory TestedDrain, Trap, Waste and Vent Piping - Tested
Satisfactory CeilingSwitches and Fixtures - Ceiling
Satisfactory GFCIReceptacles - GFCI
Satisfactory InspectedWalls and Ceiling - Inspected
Satisfactory Natural Stone TileFloor Covering - Natural Stone Tile
Satisfactory Electric Fan, WindowVentilation - Electric Fan, Window
Satisfactory Central Heating & CoolingHeating and Cooling - Central Heating & Cooling
Satisfactory Flushes, Drains, and RefillsToilet Bowl and Tank - Flushes, Drains, and Refills
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
25Inspection Details: Page of 35 Perfection Home InspectionsPage 29 of 39
BATH2Satisfactory Adequate FlowTub/Shower Faucets - Adequate Flow
Satisfactory TestedTub/Shower Drain - TestedTub overflow drains are not tested during a home inspection because they tend to leak. Recommend not filling a tub tothe overflow because this may cause a leak.
Satisfactory Natural StoneTub/Shower Enclosure - Natural Stone
BATH3Satisfactory LocatedBath3 - Located
This bathroom is located on the east side in the center of the hall.Satisfactory Door Lock and HardwareDoors - Door Lock and Hardware
Satisfactory DoubleSink - Double
Satisfactory InspectedSink Cabinet - Inspected
Satisfactory TestedSink Faucet - Tested
Satisfactory TestedDrain, Trap, Waste and Vent Piping - Tested
Satisfactory Ceiling, SkylightSwitches and Fixtures - Ceiling, Skylight
Satisfactory GFCIReceptacles - GFCI
Satisfactory TileWalls and Ceiling - Tile
Satisfactory Natural Stone TileFloor Covering - Natural Stone Tile
Satisfactory Electric FanVentilation - Electric Fan
Satisfactory Central Heating & CoolingHeating and Cooling - Central Heating & Cooling
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
26Inspection Details: Page of 35 Perfection Home InspectionsPage 30 of 39
BATH3Satisfactory Flushes, Drains, RefillsToilet Bowl and Tank - Flushes, Drains, Refills
Satisfactory Adequate FlowTub/Shower Faucet - Adequate Flow
Satisfactory TestedTub/Shower Drain - Tested
Satisfactory Natural StoneTub/Shower Enclosure - Natural Stone
BATH4Satisfactory LocatedBath4 - Located
This bathroom is located on the east side next to the office/library.Satisfactory Door Lock and HardwareDoors - Door Lock and Hardware
Satisfactory SingleSink - Single
Satisfactory TestedSink Faucet - Tested
Satisfactory TestedDrain, Trap, Waste and Vent Piping - Tested
Satisfactory Wall, Ceiling, SkylightSwitches and Fixtures - Wall, Ceiling, Skylight
Satisfactory GFCIReceptacles - GFCI
Satisfactory InspectedWalls and Ceiling - Inspected
Satisfactory TileFloor Covering - Tile
Satisfactory Electric FanVentilation - Electric Fan
Satisfactory Central Heating & CoolingHeating and Cooling - Central Heating & Cooling
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
27Inspection Details: Page of 35 Perfection Home InspectionsPage 31 of 39
BATH4Satisfactory Flushes, Drains, RefillsToilet Bowl and Tank - Flushes, Drains, Refills
BATH5Satisfactory Room LocatedBATH5 - Room Located
This bathroom is located in the garage.Satisfactory Door Lock & HardwareDoors - Door Lock & Hardware
Satisfactory SingleSink - Single
Satisfactory TestedSink Faucet - Tested
Satisfactory TestedDrain, Trap, Waste and Vent Piping - Tested
Satisfactory Ceiling, SkylightSwitches and Fixtures - Ceiling, Skylight
Satisfactory GFCIReceptacles - GFCI
Satisfactory Drywall/PlasterWalls and Ceiling - Drywall/Plaster
Satisfactory TileFloor Covering - Tile
Satisfactory Electric FanVentilation - Electric Fan
Satisfactory Electric Ceiling FixtureHeating and Cooling - Electric Ceiling FixtureNo air conditioning for this bathroom.
Satisfactory Flushes, Drains, RefillsToilet Bowl and Tank - Flushes, Drains, Refills
BED2Satisfactory Near MasterBEDROOM 2 - Near Master
This bedroom room is located closest to the master bedroom.
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
28Inspection Details: Page of 35 Perfection Home InspectionsPage 32 of 39
BED2Satisfactory Hardware CheckedDoor - Hardware Checked
Satisfactory InstalledLight Fixtures - Installed
Satisfactory 3 Prong GroundedOutlets - 3 Prong Grounded
Satisfactory InspectedWalls & Ceiling - Inspected
Satisfactory TileFloor - Tile
Satisfactory Central Heating & CoolingHeating & Cooling Source - Central Heating & Cooling
Satisfactory Approx. 44" or Less to sillWindows - Approx. 44" or Less to sill
Satisfactory Door(s) & PoleCloset - Door(s) & Pole
BED3Satisfactory Room LocationBEDROOM 3 - Room Location
This room is located in the front of the home on the east side.Satisfactory Hardware TestedDoor - Hardware Tested
Satisfactory Switched Outlet, InstalledLight Fixture - Switched Outlet, InstalledMost switched outlets are installed upside down so they can be quickly identified.
Satisfactory 3 Prong GroundedOutlets - 3 Prong Grounded
Satisfactory InspectedWalls & Ceiling - Inspected
Satisfactory Wood/Imitation WoodFloor - Wood/Imitation Wood
Satisfactory Central Heating & CoolingHeating & Cooling Source - Central Heating & Cooling
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
29Inspection Details: Page of 35 Perfection Home InspectionsPage 33 of 39
BED3Satisfactory Approx. 44" or Less to SillWindows - Approx. 44" or Less to Sill
Satisfactory Door(s) Light & PoleCloset - Door(s) Light & Pole
BED4Satisfactory Room LocationBEDROOM 4 - Room Location
This room is located on the east side next to the front bedroom.Satisfactory Hardware TestedDoor - Hardware Tested
Satisfactory Switched Outlet, InstalledLight Fixture - Switched Outlet, Installed
Satisfactory 3 Prong GroundedOutlets - 3 Prong Grounded
Satisfactory InspectedWalls & Ceiling - Inspected
Satisfactory Wood/Imitation WoodFloor - Wood/Imitation Wood
Satisfactory Central Heating & CoolingHeating & Cooling Source - Central Heating & Cooling
Satisfactory Approx. 44" or Less to SillWindows - Approx. 44" or Less to Sill
Satisfactory Door(s) Light & PoleCloset - Door(s) Light & Pole
BED5Satisfactory Room LocationBEDROOM 5 - Room Location
This room is located on the east side south of the hall bathroom.Satisfactory Hardware CheckedDoor - Hardware Checked
Satisfactory Switched Outlet, InstalledLight Fixture - Switched Outlet, Installed
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
30Inspection Details: Page of 35 Perfection Home InspectionsPage 34 of 39
BED5Satisfactory 3 Prong GroundedOutlets - 3 Prong Grounded
Satisfactory Drywall/PlasterWalls & Ceiling - Drywall/Plaster
Satisfactory Wood/Imitation WoodFloor - Wood/Imitation Wood
Satisfactory Central Heating & CoolingHeating & Cooling Source - Central Heating & Cooling
Satisfactory Approx. 44" or Less to SillWindows - Approx. 44" or Less to Sill
Satisfactory Door(s) Light & PoleCloset - Door(s) Light & Pole
OFFICE/DENSatisfactory Checked hardwareDoor - Checked hardware
Satisfactory InspectedWalls & Ceiling - Inspected
Satisfactory InstalledLight Fixture - Installed
Satisfactory Wood/Imitation WoodFloor - Wood/Imitation Wood
Satisfactory CentralHeating & Cooling - Central
Satisfactory OtherWindow - OtherSliding glass door to the exterior.
Satisfactory 3 prong groundedOutlets - 3 prong grounded
POOLSatisfactory GENERAL INFORMATIONPOOL - GENERAL INFORMATION
The spa/pool shower on the back of the house was tested. The water flow both hot and cold and the drain were alltested
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
31Inspection Details: Page of 35 Perfection Home InspectionsPage 35 of 39
POOLSatisfactory In groundType of Pool /Spa - In ground
Satisfactory ClearWater - Clear
Satisfactory PlasterPool Surface - Plaster
Satisfactory InspectedSteps & Coping - Inspected
Satisfactory None FoundAlgae - None Found
Satisfactory CheckedSkimmer Basket - Checked
Satisfactory CheckedTiles - Checked
Satisfactory TestedPool Light - Tested
Satisfactory TestedGFCI Outlet - Tested
Satisfactory GeneralDecking - General
Satisfactory InstalledAuto Fill Device - Installed
Satisfactory CheckedDeep End Drain Diverter - Checked
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
32Inspection Details: Page of 35 Perfection Home InspectionsPage 36 of 39
POOLSatisfactory TestedPump - Tested
Satisfactory TestedFilter - Tested
Satisfactory Water PerssureWater Pressure/ Gauges - Water PerssureThe water pressure gauge on the top of the swimming pool filter reads 12 PSI when the pump is running.
No TPRVSafety Concern Automatic Safety Controls - No TPRVNo temperature pressure relief valve pipe found for the pool heater. Recommend all temperature pressure relief valve pipes be within 12inches of the ground and pointed straight down.Recommend a qualified contractor evaluate and make all necessaryrepairs
Satisfactory PaintedPipes - Painted
Satisfactory TestedValves - Tested
Satisfactory Gas, SolarHeater - Gas, SolarPropane gas and solar heating for the pool also known as overgrown spa.
Satisfactory WorkingTime Clock - Working
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
33Inspection Details: Page of 35 Perfection Home InspectionsPage 37 of 39
POOLSatisfactory CartridgeFilter Type - Cartridge
Pop-upsService/Repair Auto Sweep\Self Cleaning - Pop-upsPool pop ups needed to clean the pool did not work when tested. Recommend service by a qualified swimming poolcompany or contractor.
Satisfactory Pump/motor, HeaterBonding 5 Feet From Pool - Pump/motor, Heater
Satisfactory Wall/Fence Height 5 Feet or MoreSafety Barrier - Wall/Fence Height 5 Feet or MoreEvery city has their own codes on swimming pool barriers and they should be checked by the buyer because thisinspection is not a code compliance inspection.
Satisfactory CheckedGrading Near Pool - Checked
Satisfactory NoneAutomatic Chlorinator - None
Satisfactory NoneDiving Board - None
OTHER ROOMSatisfactory GeneralOther Room - General
This room is the exercise room.Satisfactory Hardware CheckedDoor - Hardware Checked
Satisfactory InspectedWalls & Ceiling - Inspected
Satisfactory Installed, Ceiling FanLight fixture - Installed, Ceiling Fan
Satisfactory TileFloor - Tile
Satisfactory Central Heating & CoolingHeating & Cooling - Central Heating & Cooling
Satisfactory 3 prong groundedOutlets - 3 prong grounded
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
34Inspection Details: Page of 35 Perfection Home InspectionsPage 38 of 39
OTHER ROOM 2Satisfactory GeneralOther Room 2 - General
This room is the game room on the east side.Satisfactory Hardware CheckedDoor - Hardware Checked
Satisfactory DrywallWalls & Ceiling - Drywall
Satisfactory InstalledLight fixture - Installed
Satisfactory TileFloor - Tile
Satisfactory Central Heating & CoolingHeating & Cooling - Central Heating & Cooling
Satisfactory TestedWindow - Tested
Satisfactory 3 prong groundedOutlets - 3 prong grounded
Record 7124 - Webb, Roy & Joan 35900 S. Gold Rock Circle, Wickenburg, AZ 85390
35Inspection Details: Page of 35 Perfection Home InspectionsPage 39 of 39