A New UV Sensor Method for Sewer Renovation
Michael Roeling, Export Manager BKP Berolina Polyester GmbH & Co. KG, Velten, Germany
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 3
• UV Curing of CIPP since 1986
• becoming more and more popular within the last 15 years
• good quality control “online” possible
• spectrum used: 350 nm – 450 nm (UVA to visible blue)
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 4
Quality Managements steps at the installation site
Data recording with PC
Copyright: BKP
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 5
lamp switched off
lamp defect
lamp started
lamp switched on on/off of winch
lamp not activated
Data recording with PC – control mode
Quality Managements steps at the installation site
Copyright: BKP
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 6
0
10
20
30
40
50
60
70
28.06.2001 11:02 28.06.2001 11:16 28.06.2001 11:31 28.06.2001 11:45 28.06.2001 12:00 28.06.2001 12:14 28.06.2001 12:28
[cm
/min
]
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
[ba
r]
Curing speed [cm/min]
air pressure [bar]
0
20
40
60
80
100
120
140
28.06.2001 11:02 28.06.2001 11:16 28.06.2001 11:31 28.06.2001 11:45 28.06.2001 12:00 28.06.2001 12:14 28.06.2001 12:28
[°C
]
Air temperature [°C]
Laminate temperature 2 [°C]
Laminate temperature 1 [°C]
Data recording with PC – evaluation
Copyright: BKP
Quality Managements steps at the installation site
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 7
evaluation process optimization
optical measurement
light source
host pipe
optical sensor
CIPP-Liner
quality proof
Overview: objective
Source: OSSCAD
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 8
Principal configuration of UV-light measuring
Transmission measuring: • UV collimation device • optical fiber • wavelength selective receiver
Lateral UV-light launching: • no UV collimation device • special optical fiber • wavelength selective receiver
New: measuring the UV light by lateral launching it into optical fibers!
Source: OSSCAD
spectrometer
transmission measuring
ligh
tlig
ht
spectrometer
transmission measuring
ligh
tlig
ht
ligh
tlig
ht
lateral light launching
spectrometerlight
light
lateral light launching
spectrometerlightlight
lightlight
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 9
PE_S: received power with lateral launching PST: stray power related to the interaction length e: Euler‘s constant S: stray coefficient of sensor fiber
A: absorption coefficient of sensor fiber : central wave length of light
S: catch factor AN: numerical aperture l: length of interaction : lateral launch efficiency
Pk: optical power (outer core area) LA: length of sensor fiber
Mathematical model of UV light measuring
Source: OSSCAD
PE_SPST
light
PE_SPST PE_SPST
lightlightAAs
AAs
L
kNSASE
L
STASE
ePlASLP
ePLP
)(2
_
)(2
_
),(
),(
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 10
Source: https://www.tu-harburg.de/et3/students/Skripte_ss10/V772.pdf
Spectral attenuation of optical fibers – standard fibers
typical data of
quartz fibers:
for single mode fibers
for multi mode fibers
Composition of a step index fiber
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 11
Spectral attenuation behavior of standard fibers
wavelength range: 800nm to 1600nm composition of fiber: Cladding: 125µm, SiO2 – quartz glass
Core: 50µm, Ge-SiO2 – Germanium doped quartz glass Coating: 250µm, UV resistant material
Standard fibers are not usable for measuring UV light!
Spectral attenuation of optical fibers – standard fibers
area of
UV light
area of
UV light
area of
UV light
Source: OSSCAD
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 12
Optical characteristics of special fibers – plastic optical fiber (POF)
In comparison with quartz fibers POF have:
higher path attenuation (absorption)
less temperature resistance
POF are not usable for measuring UV light!
Spectral attenuation behavior of POF Attenuation
Wave Length
Attenuation
Wave Length
Source: OSSCAD
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 13
Wavelength range: 200nm to 800nm Composition of glass fiber:
Cladding: 220µm, F-SiO2 – Fluorine-doped quartz glass Core: 200µm, SiO2 – quartz glass Coating: 260µm, UV transparent material
Use of a UV transparent coating
Development of a UV resistant fiber with UV transparent coating.
Spectrum used forUV-curing
Spectrum used forUV-curing
Source: OSSCAD
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 14
Spectral distribution of UV- light source (mercury vapor lamp):
Spectrum used for
UV-curing
Spectrum used for
UV-curing
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 15
15
Laboratory test – test set-up
evaluation
µP
optoelectronic measuring device
TCP/IP
Interface
amplifier
photodiode
Spectrometer
USB
optical fiber connector
20m - UV patch cable
optical fiber connector
Liner sample:
L=50cm (20”), ID=300mm (12”), wall thickness=4.3mm
UV-light source
UVASPOT 400T
L=15-20cm
25cm
µP
optoelectronic measuring device
TCP/IP
Interface
amplifier
photodiodephotodiode
Spectrometer
USB
optical fiber connector
20m - UV patch cable
optical fiber connector
Liner sample:
L=50cm (20”), ID=300mm (12”), wall thickness=4.3mm
UV-light source
UVASPOT 400T
L=15-20cm
25cm
optical fiber connector
20m - UV patch cable
optical fiber connector
Liner sample:
L=50cm (20”), ID=300mm (12”), wall thickness=4.3mm
UV-light source
UVASPOT 400T
L=15-20cm
25cm
optical fiber connector
Liner sample:
L=50cm (20”), ID=300mm (12”), wall thickness=4.3mm
UV-light source
UVASPOT 400T
L=15-20cm
25cm
UV-light source
UVASPOT 400T
L=15-20cm
25cm
L=15-20cm
25cm25cm
Source: OSSCAD
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 16
Test with site simulation – test set-up
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 17
UV-measuring with UV-filter and automatic amplification
light chain 8 UV-lamps
UV-measuring test: September 30th 2010 length of sensor cable: 1m test 1
Ignition of lamps
All lamps “ON”
Integral transmission curve of
sensor cable as a function of time
Conditions:
- curing speed: 67cm/min
- all 8 UV lamps „On“
- UV lamp (bulb 17cm, center 10cm)
- distance between lamps: 17cm
- length of light chain: 2,48m
Start of
curing process
Liner fully cured
Light chain moves
towards sensor cable
Ignition of lamps
All lamps “ON”
Integral transmission curve of
sensor cable as a function of time
Conditions:
- curing speed: 67cm/min
- all 8 UV lamps „On“
- UV lamp (bulb 17cm, center 10cm)
- distance between lamps: 17cm
- length of light chain: 2,48m
Start of
curing process
Liner fully cured
Light chain moves
towards sensor cable
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 18
UV-measuring with UV-filter and automatic amplification
light chain with lamps 1+2 and 7+8 only
UV-measuring test: September 30th 2010 length of sensor cable: 1m test 2
Start of curing process when
UV lamps 1+2 pass by
Liner fully cured after
passage of UV lamps 7+8
Integral transmission curve of
sensor cable as a function of time
Conditions:
- curing speed: 33cm/min
-UV lamps 1+2+7+8 „On“
- UV lamp (bulb 17cm, center 10cm)
- distance between lamps: 17cm
- length of light chain: 2,48m
Start of curing process when
UV lamps 1+2 pass by
Liner fully cured after
passage of UV lamps 7+8
Integral transmission curve of
sensor cable as a function of time
Conditions:
- curing speed: 33cm/min
-UV lamps 1+2+7+8 „On“
- UV lamp (bulb 17cm, center 10cm)
- distance between lamps: 17cm
- length of light chain: 2,48m
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 19
Laboratory test – sample for calibration
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 20
Laboratory test – sample for calibration
Prof. Dr. Ulrich Glombitza, Treffen SARTEX– 29. Mai 2009
Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 21
Thank You For Your Attention!
BKP Berolina Polyester GmbH & Co. KG
Heidering 28
16727 Velten
Germany
Phone: +49 (3304) 20 88 - 100
Fax: +49 (3304) 20 88 - 110
e-mail: [email protected]
Web: www.bkp-berolina.de
Top Related