Motor DataP/N 33224
Item Energy Efficient Motor
Motor Type 3-Phase
Enclosure Totally Enclosed Fan-Cooled
Duty Inverter
HP 2
Nameplate RPM 1725
Voltage 208-230/460
NEMA/IEC Frame 56H
Service Factor 1.00
Hz 60
Nominal Efficiency 82.5
Mounting Base
Bearings Double Shielded Ball
Thermal Protection None
Full Load Amps 6.0-5.8/2.9
Rotation CW/CCW
Insulation Class B
Ambient (C) 40
Efficiency Group Standard
Shaft Dia. (In.) 5/8
Shaft Length (In.) 1 7/8
Frame Material Steel
Body Dia. (In.) 6.3
NEMA Design B
Phase 3
Rated 50 Hz Operation on 190/380V at 5/6 of 60 Hz HP and RPM at 1.0 SF
Warranty (Years) 2
Model No: 3N486BB Curve at 230 Volts , 60Hz, 2 HP,1725 RPM, 208-230/460 V, 60Hz, 3 Phase Customer: WWG Document 3N486BB
Full load torque 97.3 Oz-ft Full load Amps 6.2-6.0/3.0 Amps
BD Torque 353.8 Oz-ft PU Torque 226.00 Oz-ft
LR Torque 304.1 Oz-ft LR Amps@230V 45.34 Amps
Winding SpecWTS070817P7 Prepared By Shirish 10/29/2007
DAYTON Electric Mfg Co.
Typical Performance Curve for AC motor
PLOT FOR WATTS INPUT
0
2000
4000
6000
8000
10000
12000
14000
0 500 1000 1500 2000
Speed (rpm)
Inp
ut
(Watt
s)
PLOT FOR EFFECIENCY
0
10
20
30
40
50
60
70
80
90
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Speed (rpm)
Eff
ecie
ncy (
%)
PLOT FOR TORQUE
0
50
100
150
200
250
300
350
400
0 500 1000 1500 2000
Speed (rpm)
To
rqu
e (
Oz-f
t)
PLOT FOR LINE CURRENT
0
5
10
15
20
25
30
35
40
45
50
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Speed (rpm)
Lin
e C
urr
en
t (A
mp
s)