Automatic horizontal sliding landing door
www.fermator.com 2PREMIUM
Door configuration
APPLICATION RANGE
Opening Clear opening - PL (mm) Clear height - HL (mm)
C2 700 - 2.400
1.800 - 3.000
C4 900 - 3.000C6 1.600 - 3.000T1 600 - 1.200T2 700 - 1.600T3 700 - 2.000
FRAME DEFINITION
Frame depth (mm)
Jamb J1(mm)
Header(mm)
Jamb J2(mm) Remarks
Frame type Options
STD
MSS MV
MSS MH
Con
ceal
ed
Lateralcovers
Withoutextra-strokeMRL Without
lateral punching
60 120 210 120 - > 120 + Δ 10 > 210 + Δ 10 > 120 + Δ 10 -
50 70 80 70 - MSS MV: Frame without sill supplement with visible sill support.
MSS MH: Frame without sill supplement with concealed sill support.Without extra-stroke: Closing jamb without labyrinth.
MRL: Jamb ready for lift control cabinet in machine roomless installations.
PANELS
Opening
Steel panels Glass panels
Metal sheet (1)
Double skin Vision Fritted
visionWien type
visionBevel big
visionFlush big
visionFull glass in skirting
Full glass in
mooringsAluminium
glass
W
C2 - C4 - C6 T1 - T2 - T3
NO F.RF.R. E30 (2)
F.R. E120 (2)
F.R. EI30 (2)
F.R. EI60 (2)
F.R. EI120 (2)
F.R. EW30 (2)
F.R. EW60 (2)
NO F.RF.R. E120 (2)
NO F.RF.R.E60
F.R.E120F.R.EI30
NO F.RF.R.E60
F.R.E120F.R.EI30
NO F.R
1 Solid execution option. 2 Execution with smoke seal protection available.
F.R.: Fire rated according to EN 81-58.
Anti-trapping safety device option
C2
LIFT APPLICATION Door cycles per year: Up to 2.500.000.
Maximum cycle rate of the door: Up to 360 cycles per hour.Maximum lift speed: Up to 6 m/s.
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
www.fermator.com3 PREMIUM
Door configuration
STANDARDS
Opening EN 81-1/2Safety rules
EN 81-21Existing buildings
EN 81-41Impaired mobility
EN 81-71Vandal resistant lifts EN 81-72
Firefighting liftsEN 81-20/50Safety rulesCat. I Cat. II
C2 - C4 - C6 T1 - T2 - T3
SILL SUPPLEMENTS
Type of supplement Aluminium Reinforced aluminium Steel Massive
Profile detail
Availability
FRAME DETAIL
Frame type STD MSS MV MSS MH Concealed
Frame detail - - -
MSS MV: Frame without sill supplement with visible sill support.MSS MH: Frame without sill supplement with concealed sill support.
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
SILLS
Type of sill Aluminium Reinforced aluminium Steel Steel concealed Massive
Profile detail
Availability Heated sill option
Debris holes
www.fermator.com 4PREMIUM
COMPATIBILITY
90 9030
6090
210 500260
110
±0
90
HL
AFO: HL + 220
HL + 345
H
MOT
OR
Case Premium PM car doorCoupling Asymmetrical clutch Pre-opening asymmetrical clutch
Unlocking zone +102 / -148 +232 / -269Toe guard type Standard Standard
H 265 395Thickness 1 1
Range All AllT2 opening shown.
If not otherwise indicated all dimensions in mm.
Door configuration
PANEL REGULATION SUPPORT AND PANEL GUIDE
Type of panel regulation support Direct fastening
Type of panel guide Plus
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
PROTECTION
Opening
IP21Protection against a solid foreign body of 12,5 mm or more in diameter and
protected against vertically falling drops of water.
IPX3Protected against
sprays of water up to 60 degrees from the
vertical.
IP54Protection against debris and protected against
water splashed from all directions.
IP65Sealed against debris and protected against
jets ofwater from all directions.
EExExplosion proof, Group II (surface industries) and Category 2 (explosive
atmosphere between 10 and 1.000 hrs/yr).Magnetic contact Mechanical contact
C2 - C4 - C6 T1 - T2 -T3 (3) (4)
(3) Only for T1 - T2 - T3 - C2 - C4 - C6.(4) Only for T1 - T2 - C2 - C6.
www.fermator.com5 PREMIUM
Technical features
INSTALLATIONPre-adjusted and tested to simplify the installation.
T2 mechanism
DOOR HOISTWAY PROJECTION (DHP) - FIXING BRACKETS
DHPtype
C2 C4 C6 T1 T2 T3DHP*(mm)
Bracket DHP*(mm)
Bracket DHP*(mm)
Bracket DHP*(mm)
Bracket DHP*(mm)
Bracket DHP*(mm)
Bracket
1 0 - 31 X A 0 - 37,5 X A 0 - 32,5 D 0 - 31 X A 0 - 38 X A 0 - 32,5 D2a - - 37,6 - 90 W 32,6 - 125 D - - 39 - 89 W 32,6 - 125 D2b 32 - 93 W 91 - 140 D 126 - 175 V2 32 - 93 W 90 - 140 D 126 - 175 V23 94 - 124 V8 141 - 150 V2 176 - 195 V7 94 - 124 V8 141 - 150 V2 176 - 195 V7
Brackettype
A D V2 V7 V8 X W
Thickness(mm) 5 5 4 4 4 5 5
*See DHP dimension in sill detail (technical drawings pages).
GENERAL FEATURESNoise level 48 dB.Total weight Reference: T2 PL 800 mm HL 2.000 mm 120 x 60 mm frame, with sheet metal panels - 84 kg.
Safety closing system
C2: PL 700 - 2.400 mm = Counterweight / PL 700 - 1.200 mm = Spring.C4: PL 900 - 3.000 mm = Counterweight / PL 900 - 2.400 mm = Spring.
C6: PL 1.600 - 3.000 mm = Counterweight.T1: PL 600 - 1.200 mm = Counterweight.
T2: PL 700 - 1.600 mm = Counterweight / PL 700 - 1.200 mm = Spring.T3: PL 700 - 2.000 mm = Counterweight / PL 700 - 1.200 mm = Spring.
www.fermator.com 6PREMIUM
S
S
S
L
U
L
= =
==
160
6054
J1 J2
3042
5
49 5
54114
60
30
210
5420 60
= =
DHP(1)
DHP(1)
90
PL - 80
2PL + 40
2PL + 50
PL + 25
PL
HL
+ 12
1
HL
+ 21
0
HL
+ 10
HL
PL 2PL + 50
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
MECHANICALDETAILS
Technical drawing2 panel centre parting door
SILL DETAIL
thickness3
thickness3
54 mm sill
Safety closing system
Counterweight Spring
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.- If not otherwise indicated all dimensions in mm.
Notes:
www.fermator.com7 PREMIUM
U
L
S
S
L
S
= =
==
20 90 60
30
210
4040 5590
15060
30425
B
J1 J2
6090
= =
DHP(1)
G
DHP(1)
90
PL - 80
1,5 PL + 40
HL
+ 12
1
HL
+ 10
HL
+ 21
0
HL
1,5 PL + 50
0,75PL + 25
PL
PL
1,5 PL + 50
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
Technical drawing4 panel centre parting door
90 mm sillSingle coupling system (PL 900 - 1.150)
MECHANICALDETAILS
SILL DETAIL
Safety closing system
Counterweight Spring
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.- If not otherwise indicated all dimensions in mm.
Notes:
thickness3
thickness3
PL 900 950 1000 1050 1100 1150
G 10 57 45 32 20 7
B 100 160
www.fermator.com 8PREMIUM
Technical drawing4 panel centre parting door
90 mm sillDouble coupling system (PL 1.200 - 3.000)
Safety closing system
Counterweight Spring
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.- If not otherwise indicated all dimensions in mm.
Notes:
U
L
S
L
S
S
S
= =
==
20 90 70
30
210
4040 5590
16070
30425
120 120
7090
= =
DHP(1)
DHP(1)
9090
= =160 160
PL - 80
1,5PL + 40
HL
+ 12
1
HL
+ 10
HL
HL
+ 21
0
1,5PL + 50
PL
PL
1,5PL + 50
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
MECHANICALDETAILS
SILL DETAIL
thickness3
thickness3
www.fermator.com9 PREMIUM
L
SS
S
S
L
U
DHP(1)
= =
= = =
==
=160= 160
6013
5
404040 55
135195
605
3042
5
J1 J2
30
210
13520 60
DHP(1)
90
G
90
G
PL
1,35PL + 50
HL
+ 21
0
HL
+ 12
1
HL
+ 10
HL
PL - 80
1,35PL + 40
1,35PL + 50
PL
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
Technical drawing6 panel centre parting door
135 mm sill
MECHANICALDETAILS
SILL DETAIL
Safety closing system
Counterweight
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.- If not otherwise indicated all dimensions in mm.
Notes:
thickness3
thickness3
PL 1600 1650 > 1650
G 20 0
www.fermator.com 10PREMIUM
S
L
U
L
S
= =
J2 - 25
J2 - 205
160
4560
15J2J1
J2 + 40
30
210
54 6020
DHP(1)
3042
5
49 5
54114
60
DHP(1)
2PL + 40
PL
PL - 80PL + 40
HL
+ 12
1 H
L +
210
HL
+ 10
HL
2PL + 50
PL
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
Technical drawing1 panel side opening door
54 mm sill
MECHANICALDETAILS
SILL DETAIL
Safety closing system
Counterweight
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.- If not otherwise indicated all dimensions in mm.
Notes:
thickness3
thickness3
www.fermator.com11 PREMIUM
L
S
S
Y
Y
210
4040 5590
15060
3042
5
9020 60
30
6090
J1 J215
160
J2 - 205
80
40
= =J2 + 40
L
U
DHP(1)
DHP(1)S
J2 - 25
35
HL
HL
+ 12
1
HL
+ 21
0
PL
1,5PL + 40
PL - 800,5PL + 40
PL 1,5PL + 50
HL
+ 10
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
Technical drawing2 panel side opening door
MECHANICALDETAILS
SILL DETAIL
90 mm sill
Safety closing system
Counterweight Spring
DHP
Upper bracket
Lower bracket
1 See DHP details in technical features page.Y With optional steel concealed sill, this extra space is required.- If not otherwise indicated all dimensions in mm.
Notes:
thickness3
thickness3
PREMIUM www.fermator.com 12
S
S
S
L
U
L
= =
J2 + 40
13520 60
30
210
404040 55
135195
605
3042
5
160J2 - 205
6013
5
J1 J2
15DHP(1)
DHP(1)
J2 - 25G
PL - 800,35PL + 40
PL
1,35PL + 50
HL
+ 12
1
HL
+ 21
0
HL
1,35PL + 40
PL
H
H
Con
cent
ricØ
66
Ecce
ntric
Ø 2
6
Technical drawing3 panel side opening door
135 mm sill
MECHANICALDETAILS
SILL DETAIL
Safety closing system
Counterweight Spring
DHP
Upper bracket
Lower bracket
Notes:
1 See DHP details in technical features page.G In PL 700 to 800 in open position, the locking device sticks out 40 mm maximum.- If not otherwise indicated all dimensions in mm.
thickness3
thickness3
PL 700 750 > 750
G 40 25 0