Spec Data SheetQuote
Masoneilan Valves 35-35212
Quantity 1
Item Revision1Item NoGeneral Controlar el nivel de condensado en Slug Catcher V-03Service
LCV-110120Tag:
78-40 / 1.5 inch st. st.
English / -
316 St. St. / st.st. double Ferrule / 0.25 inch / psi-kPa-bar-kg/cm2
.25 NPT /
/
Pneumatic
2 / Horizontal Line (Default)
Eccentric
A194 gr 8
A193 gr B8 cl 1
125 - 250 AARH
0,1775 0,187 0,1965in
-
Flow Action
Serial Plate Language(s):
FN Notes
Tubing Mat l / Fitting Type / Tubing Size(min.) / Gauge scale:
Enclosure RatingAir Connection /Elect Conn
Type
3-15 psi g / Linear
35 / 6
Linear
Eccentric plug
316 St. St. / 440C St. St.
Characteristic
Plug Type
33 ft/s dia.
Body Studs
Body Nuts
/
/
/
0,28- 6,625 - / 0,28- 6,625
ITP-1ITP:
Mounting / Installation
/
0,82440,82790,8325
0,1417 [O]0,1284 [O]0,1156 [O]ft/s [I]nlet [O]utlet
FL
Valve velocity
Area Class / PED 97/23 CE Pass / Category
Notes to Customer:
% lift
Sound Level, IECrequired Cv
Flowing Cond.
Liquid Gf
ViscosityVapor Pressure
Critical pressure
Temperature
Outlet Pressure
Inlet Pressure
Flow Rate
Leakage Class / NACE
Size
Stem/Shaft Mtl
Seat Ring Mtl
Rated Cv
Cage:Retnr / Guide Matl
Plug:Ball:Disk Matl
Limit Stop
Trim Type
Packing Type
Body & Bonnet Matl
Rating / End Conn /sch
Body Type
Face Finish
Bonnet Type / Bellows
Size (In x Body x Out)
Model No
Line Size - Schedule - OD - Wall Inlet / Outlet
Process Fluid / Fluid State
Design Press / Design Temp
Sizing Conditions Units Service
Inputs
Service
Results
Body Bonnet
Trim
Model / Size
Shutoff Pressure
Type
Fail Position
Manual Override
Actuator
Agency / Approval
Approval Description:
Airset / Gauge
Model
Input Signal / Characteristic
Tag
Positioner
psi g100
48 psi g /80 deg F /
inin
ANSI Class
- -
LY-110120
Braided PTFE/Carbon or aramid core
CL 300 / Flangeless
STD6- STD6
4710P
-
Closed
Spring-diaphragm
reduced area
630(H1075) St. St.
316 St. St.
316L St.St.Hard Faced
Flow to Close
58
A216 gr WCC
Integral/
in3
Globe, Rotary
35-35212
41,8540,7139,5
< 70< 70< 70
22,7822,0521,26
LaminarLaminarLaminar
0,9640,9640,964
125212521252
2,062,062,06
320032003200
808080
464646
484848
10796,9687,3
dBA
centipoisepsi a
psi a
deg F
psi g
psi g
bbl/d
OtherMaxNormMin
LiquidCONDENSADO
IV
Paint System / Prep: P01-1 MN Standard CES 1036 Table 1 /Solvent Cleaning, standard
Body Paint Color: Gray, standard (RAL 7001)
Yoke: Red, standard (RAL 3011)
Actuator Case: Red, standard (RAL 3011)
Handwheel:
Revisions Item Revision Description Date By Contact
Ysidro Mundarain Phone: +58-291-3153522
Accessory Sheet X Notes Sheet
lune
s, 2
2 de
dic
iem
bre
de 2
014
Supply Pressure / Oversize Factor 20 psi g / 0
Sel
ler,
at i
ts o
ptio
n an
d at
no
expe
nse
to th
e cu
stom
er, m
ay m
ake
desi
gn c
hang
es to
goo
ds o
r m
ater
ials
not
impa
ctin
g fo
rm, f
it, o
r fu
nctio
n
PID No
Serial No Line No
Bench Range / Travel / Stroke Time 7-15 psi g / 50 deg /
Yoke Matl / Volume Chamber
Diagnostics Level / Position Transmit - / -
Cast Iron / -
Slug Catcher V-03
ING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2
LCV-110120
1
1
Controlar el nivel de condensado en Slug Catcher V-03
ValSpeQ v
Accessory Sheet
Quote No:
Customer:
RFQ No:
CustomerPO:
Revision:
Revision:
Project:
End User:
End User Location:
Tag:
General Item No
Quantity:
Item Revision
Service
PID No
Serial No
Quote
Masoneilan ValvesS
olen
oid
NEMA Types 3,4,7,9
-
cl. II; gr. E,F,G
Explosion Proof
CSA
Stainless steel
.5 Inch NPTF
-
- / Airset / Gauge
SunShade
Elect Connection
Solenoid Body Matl
Agency
ApprovalApproval Desc
Approval Note
Enclosure Rating
Asco / Three Way
EFHT8320G203
1
Normally Closed
Vents deenergized
24 VDC
.25 In / 0,25
60 / .25 NPTMax Shutoff / Air Connection
Orifice Size / Rated CV
Voltage
Position
Action
Quantity:
Model:
Manufacturer / Type
Gauge Internals
Tag:
lunes, 22 de diciembre de 2014
ING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2ValSpeQ vFactory
Quote No:
Customer:
RFQ No:
CustomerPO:
Calculation Sheet
Project:
End User:
End User Location:Revision:
Revision:
Quote
Size v3.99.2
Masoneilan Valves
6
6
/
/
STD
STD
/
/
6,625
6,625
/
/
0,28
0,28
LCV-110120
in
in
CONDENSADO
Liquid
Min Norm Max
bbl/d
psi g
psi g
psi
deg F
psi a
psi a
centipoise
Cv x 1
dBA
in
ft/s [I]nlet [O]utlet
87,3 96,96 107
48 48 48
46 46 46
2 2 2
80 80 80
2,06 2,06 2,06
3200 3200 3200
1252 1252 1252
0,964 0,964 0,964
Laminar Laminar Laminar
21,26 22,05 22,78
21,26 22,05 22,78
< 70 < 70 < 70
39,5 40,71 41,85
36,66 38,02 39,28
0,8325 0,8279 0,8244
0,1815 0,1815 0,1815
0,1775 0,187 0,1965
0,1156 [O] 0,1284 [O] 0,1417 [O]
35-35212
58
Eccentric plug
Controlar el nivel de condensado en Slug Catcher V-03
1
1
3 in ASME CL 300
Tag
General
Siz
ing
Dat
aS
ervi
ce C
ondi
tions
Sizing Conditions Units
Flow Rate
Inlet Pressure
Outlet Pressure
Pressure Drop
Temperature
Vapor Pressure
critical pressure
Viscosity
Liquid Gf
flowing cond.
required Cv.
oversize req Cv.
sound level, IEC
% lift
% Cv
FL
critical FL
33 ft/s dia.
valve velocity
Sizing Warning:
Notes to Customer
Restrictor Sheet
Process Fluid / Design Press
Fluid State / Min / Max Design Temp:
Service
PID No
Serial No
Item No Item Revision
Quantity
Size (In x Body x Out):
Model No:
Rated Cv:
Trim Type:
Inlet Pipe Size / Sch / OD /Wall:
Outlet Pipe Size / Sch / OD / Wall:
48 psi g
/80 deg F
/
/Flu
id
% Flashing
lunes, 22 de diciembre de 2014
CUSTOMER
CUSTOMER REFERENCE NO.
MN INTERNAL REF
Engineer:
Date:
Revision:
ING. MARIA GABRIELA GOMEZ :
INSPECTION AND TEST PLAN FORM FOR CONTROL VALVES
% inspect ORG 1 ORG 2 ORG 3Requirements Standards ReportTesting Plan RevSub Category
Page 1 of 1
Valid for :
Ysidro Mundarain
0Standard ITP
LCV-110120
Acceptance Criteria
Quote
[ ITP-1 ]Masoneilan Valves
ASME B16-34Regulation & Design Code ¨-
CMTR / EN 10204 3.1 / ISO 10474 3.1B Melt chemical analysis and mechanical propertiesPressure containing parts(body,
bonnet, cover...)
¨ITP items
MSS SP 55 Visual Examination accessible areas ¨ITP items
COC / EN 10204 2.1 / ISO 10474 2.1 Melt chemical analysis and mechanical propertiesPressure retaining parts(Trim) ¨ITP items
COC / EN 10204 2.1 / ISO 10474 2.1 Melt chemical analysis and mechanical propertiesBody bonnet bolting ¨ITP items
ASME B31.3 / B31.1 Visual inspection of BWNDT/Inspection ¨BW items
ASME B16.34/EN 12266.1/IEC 60534-4/ISA S 75.19 Hydrostatic TestTesting ¨ITP items
FCI 70.2/IEC 60534-4/EN 1349 Plug/Seat Leakage Test ¨ITP items
IEC 60534-4 Packing Leakage Test ¨ITP items
IEC 60534-4 Standard Functional Test ¨ITP items
Visual / Dimensional / Marking / Identification /
Painting visual Check and Document Review
Inspection of Assembled ProductFinal inspection ¨ITP items
StandardCleaning ¨ITP items
Masoneilan standardPainting ¨ITP items
Masoneilan standardPackaging ¨ITP items
SNT TC1A or EN 473 or equivalent NDT operators level IICertification ¨-
ASME IX Process & welders certified ¨-
INSPECTION REQUIREMENTS
Symb. Organization Contact Name, Phone N° or E-mail Inspection Notice
ORG 1
ORG 2
ORG 3
Partial final inspection authorized
Final Inspection Release Note
Release Note For Packaging
None
None
None
Additional comments:
¨
¨
¨
Primary / Secondary Serial Plate Language / Contractual: English / - / English
*Important Note: When "Report" check box is ticked,
test reports are to be submitted to customer.
W-WITNESS POINT
H-HOLD POINT
R-DOCUMENTATION REVIEW POINT
Supplier will provide a date at which the product is available for witness.
Supplier may proceed with manufacturing past the witness date.
Same as witness point, however supplier cannot proceed with manufacturing
past the witness date unless waiver from the customer/agency.
ING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2
LCV-110120
1
1
Controlar el nivel de condensado en Slug Catcher V-03
1 LCV-110120 [35-35212] 3in, Carbon Steel, ASME CL 300, A216 gr WCC, Flangeless
Eccentric plug Cv 58
ValSpeQ v
Flow Curve Sheet
Quote No:
Customer:
RFQ No:
CustomerPO:
Revision:
Revision:
Project:
End User:
End User Location:
Tag
General Item No
Quantity
Item Revision
Service
PID No
Serial No
Quote
Masoneilan Valves
@ffCond1 =
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100
@ffCond1@ffCond2@ffCond3@ffCond4@ffCond5@ffCond6@ffCond7@ffCond8@ffPctCv
% Travel
% C
v
Min
@ffCond2 =
@ffCond3 =
@ffCond4 =
Norm
Max
Other
@ffCond5 = Case 5
@ffCondi6 = Case 6
@ffCond7 = Case 7
@ffCond8 = Case 8
lunes, 22 de diciembre de 2014
ValSpeQ vING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2
Quote No:
Customer:
RFQ No:
CustomerPO:
Revision:
Revision:
Project:
End User:
End User Location:
Spec Data SheetQuote
Masoneilan Valves 35-35212
Quantity 1
Item Revision1Item NoGeneral Controlar el nivel de condensado en el Amortiguador V-02Service
LCV-110220Tag:
78-40 / 1.5 inch st. st.
English / -
316 St. St. / st.st. double Ferrule / 0.25 inch / psi-kPa-bar-kg/cm2
.25 NPT /
/
Pneumatic
2 / Horizontal Line (Default)
Eccentric
A194 gr 8
A193 gr B8 cl 1
125 - 250 AARH
0,3549 0,3741 0,3925in
-
Flow Action
Serial Plate Language(s):
FN Notes
Tubing Mat l / Fitting Type / Tubing Size(min.) / Gauge scale:
Enclosure RatingAir Connection /Elect Conn
Type
3-15 psi g / Linear
35 / 6
Linear
Eccentric plug
316 St. St. / 440C St. St.
Characteristic
Plug Type
33 ft/s dia.
Body Studs
Body Nuts
/
/
/
0,28- 6,625 - / 0,28- 6,625
ITP-1ITP:
Mounting / Installation
/
0,7880,79160,7954
0,5653 [O]0,5135 [O]0,462 [O]ft/s [I]nlet [O]utlet
FL
Valve velocity
Area Class / PED 97/23 CE Pass / Category
Notes to Customer:
% lift
Sound Level, IECrequired Cv
Flowing Cond.
Liquid Gf
ViscosityVapor Pressure
Critical pressure
Temperature
Outlet Pressure
Inlet Pressure
Flow Rate
Leakage Class / NACE
Size
Stem/Shaft Mtl
Seat Ring Mtl
Rated Cv
Cage:Retnr / Guide Matl
Plug:Ball:Disk Matl
Limit Stop
Trim Type
Packing Type
Body & Bonnet Matl
Rating / End Conn /sch
Body Type
Face Finish
Bonnet Type / Bellows
Size (In x Body x Out)
Model No
Line Size - Schedule - OD - Wall Inlet / Outlet
Process Fluid / Fluid State
Design Press / Design Temp
Sizing Conditions Units Service
Inputs
Service
Results
Body Bonnet
Trim
Model / Size
Shutoff Pressure
Type
Fail Position
Manual Override
Actuator
Agency / Approval
Approval Description:
Airset / Gauge
Model
Input Signal / Characteristic
Tag
Positioner
psi g100
51 psi g /80 deg F /
inin
ANSI Class
- -
LY-110220
Braided PTFE/Carbon or aramid core
CL 300 / Flangeless
STD6- STD6
4710P
-
Closed
Spring-diaphragm
reduced area
630(H1075) St. St.
316 St. St.
316L St.St.Hard Faced
Flow to Close
58
A216 gr WCC
Integral/
in3
Globe, Rotary
35-35212
53,9952,851,54
< 70< 70< 70
31,6330,5929,48
LaminarLaminarLaminar
0,9640,9640,964
125212521252
2,062,062,06
320032003200
808080
484848
515151
427387,83349
dBA
centipoisepsi a
psi a
deg F
psi g
psi g
bbl/d
OtherMaxNormMin
LiquidCONDENSADO
IV
Paint System / Prep: P01-1 MN Standard CES 1036 Table 1 /Solvent Cleaning, standard
Body Paint Color: Gray, standard (RAL 7001)
Yoke: Red, standard (RAL 3011)
Actuator Case: Red, standard (RAL 3011)
Handwheel:
Revisions Item Revision Description Date By Contact
Ysidro Mundarain Phone: +58-291-3153522
Accessory Sheet Notes Sheet
lune
s, 2
2 de
dic
iem
bre
de 2
014
Supply Pressure / Oversize Factor 20 psi g / 0
Sel
ler,
at i
ts o
ptio
n an
d at
no
expe
nse
to th
e cu
stom
er, m
ay m
ake
desi
gn c
hang
es to
goo
ds o
r m
ater
ials
not
impa
ctin
g fo
rm, f
it, o
r fu
nctio
n
PID No
Serial No Line No
Bench Range / Travel / Stroke Time 7-15 psi g / 50 deg /
Yoke Matl / Volume Chamber
Diagnostics Level / Position Transmit - / -
Cast Iron / -
Amortiguador V-02
ING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2ValSpeQ vFactory
Quote No:
Customer:
RFQ No:
CustomerPO:
Calculation Sheet
Project:
End User:
End User Location:Revision:
Revision:
Quote
Size v3.99.2
Masoneilan Valves
6
6
/
/
STD
STD
/
/
6,625
6,625
/
/
0,28
0,28
LCV-110220
in
in
CONDENSADO
Liquid
Min Norm Max
bbl/d
psi g
psi g
psi
deg F
psi a
psi a
centipoise
Cv x 1
dBA
in
ft/s [I]nlet [O]utlet
349 387,83 427
51 51 51
48 48 48
3 3 3
80 80 80
2,06 2,06 2,06
3200 3200 3200
1252 1252 1252
0,964 0,964 0,964
Laminar Laminar Laminar
29,48 30,59 31,63
29,48 30,59 31,63
< 70 < 70 < 70
51,54 52,8 53,99
50,83 52,74 54,53
0,7954 0,7916 0,788
0,217 0,217 0,217
0,3549 0,3741 0,3925
0,462 [O] 0,5135 [O] 0,5653 [O]
35-35212
58
Eccentric plug
Controlar el nivel de condensado en el Amortiguador V-02
1
1
3 in ASME CL 300
Tag
General
Siz
ing
Dat
aS
ervi
ce C
ondi
tions
Sizing Conditions Units
Flow Rate
Inlet Pressure
Outlet Pressure
Pressure Drop
Temperature
Vapor Pressure
critical pressure
Viscosity
Liquid Gf
flowing cond.
required Cv.
oversize req Cv.
sound level, IEC
% lift
% Cv
FL
critical FL
33 ft/s dia.
valve velocity
Sizing Warning:
Notes to Customer
Restrictor Sheet
Process Fluid / Design Press
Fluid State / Min / Max Design Temp:
Service
PID No
Serial No
Item No Item Revision
Quantity
Size (In x Body x Out):
Model No:
Rated Cv:
Trim Type:
Inlet Pipe Size / Sch / OD /Wall:
Outlet Pipe Size / Sch / OD / Wall:
51 psi g
/80 deg F
/
/Flu
id
% Flashing
lunes, 22 de diciembre de 2014
CUSTOMER
CUSTOMER REFERENCE NO.
MN INTERNAL REF
Engineer:
Date:
Revision:
ING. MARIA GABRIELA GOMEZ :
INSPECTION AND TEST PLAN FORM FOR CONTROL VALVES
% inspect ORG 1 ORG 2 ORG 3Requirements Standards ReportTesting Plan RevSub Category
Page 1 of 1
Valid for :
Ysidro Mundarain
0Standard ITP
LCV-110220
Acceptance Criteria
Quote
[ ITP-1 ]Masoneilan Valves
ASME B16-34Regulation & Design Code ¨-
CMTR / EN 10204 3.1 / ISO 10474 3.1B Melt chemical analysis and mechanical propertiesPressure containing parts(body,
bonnet, cover...)
¨ITP items
MSS SP 55 Visual Examination accessible areas ¨ITP items
COC / EN 10204 2.1 / ISO 10474 2.1 Melt chemical analysis and mechanical propertiesPressure retaining parts(Trim) ¨ITP items
COC / EN 10204 2.1 / ISO 10474 2.1 Melt chemical analysis and mechanical propertiesBody bonnet bolting ¨ITP items
ASME B31.3 / B31.1 Visual inspection of BWNDT/Inspection ¨BW items
ASME B16.34/EN 12266.1/IEC 60534-4/ISA S 75.19 Hydrostatic TestTesting ¨ITP items
FCI 70.2/IEC 60534-4/EN 1349 Plug/Seat Leakage Test ¨ITP items
IEC 60534-4 Packing Leakage Test ¨ITP items
IEC 60534-4 Standard Functional Test ¨ITP items
Visual / Dimensional / Marking / Identification /
Painting visual Check and Document Review
Inspection of Assembled ProductFinal inspection ¨ITP items
StandardCleaning ¨ITP items
Masoneilan standardPainting ¨ITP items
Masoneilan standardPackaging ¨ITP items
SNT TC1A or EN 473 or equivalent NDT operators level IICertification ¨-
ASME IX Process & welders certified ¨-
INSPECTION REQUIREMENTS
Symb. Organization Contact Name, Phone N° or E-mail Inspection Notice
ORG 1
ORG 2
ORG 3
Partial final inspection authorized
Final Inspection Release Note
Release Note For Packaging
None
None
None
Additional comments:
¨
¨
¨
Primary / Secondary Serial Plate Language / Contractual: English / - / English
*Important Note: When "Report" check box is ticked,
test reports are to be submitted to customer.
W-WITNESS POINT
H-HOLD POINT
R-DOCUMENTATION REVIEW POINT
Supplier will provide a date at which the product is available for witness.
Supplier may proceed with manufacturing past the witness date.
Same as witness point, however supplier cannot proceed with manufacturing
past the witness date unless waiver from the customer/agency.
ING. MARIA GABRIELA GOMEZ
SISTEMA DE RECOLECCIÓN DE GAS EN BAJA PR
PDVSA
CAMPO MELONES MORICHAL
3.99.2
LCV-110220
1
1
Controlar el nivel de condensado en el Amortiguador V-02
1 LCV-110220 [35-35212] 3in, Carbon Steel, ASME CL 300, A216 gr WCC, Flangeless
Eccentric plug Cv 58
ValSpeQ v
Flow Curve Sheet
Quote No:
Customer:
RFQ No:
CustomerPO:
Revision:
Revision:
Project:
End User:
End User Location:
Tag
General Item No
Quantity
Item Revision
Service
PID No
Serial No
Quote
Masoneilan Valves
@ffCond1 =
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100
@ffCond1@ffCond2@ffCond3@ffCond4@ffCond5@ffCond6@ffCond7@ffCond8@ffPctCv
% Travel
% C
v
Min
@ffCond2 =
@ffCond3 =
@ffCond4 =
Norm
Max
Other
@ffCond5 = Case 5
@ffCondi6 = Case 6
@ffCond7 = Case 7
@ffCond8 = Case 8
lunes, 22 de diciembre de 2014
Top Related