6
TECHNICAL INFORMATION
2
from unit of with conver- in units of from units of with conver- into units ofmeasurement sion factor measurement measurement sion factor measurement
bar 1000 mbar mbar 0,001 bar
mbar 100 Pa Pa 0,01 mbar
mmWS 0,098 mbar mbar 10,2 mm H2O
mWS 98,07 mbar mbar 0,0102 mm H2O
Pressure
Pressure
Pressure
Pressure
Conversion tableUnits of measurement
European units of measurement in the USA
Pressure
Pressure
Pressure
Volumetric flow rate
Volumetric flow rate
Electrical Power output
Length
Length
Length
Length
Weight
Pressure
Volumetric flow rate
Example for conversion
from SI-unit of with conver- into anglo-amer. from anglo-amer. with conver- into SI-units ofmeasurement sion factor unit of measur. unit of measur. sion factor measurement
mbar 0,0145 psi = lb/in2 psi = lb/in2 68,95 mbar
bar 14,5 psi = lb/in2 psi = lb/in2 0,0689 bar
mbar 0,402 inches water inches water 2,49 mbar
m3/min 264,2 gal/min gal/min 0,00379 m3/min
m3/min 35,31 cfm cfm 0,0283 m3/min
kW 1,341 hp hp 0,746 kW
mm 0,0394 inch inch 25,4 mm
m 39,37 inch inch 0,0254 m
mm 0,00328 ft ft 305 mm
m 3,28 ft ft 0,305 m
kg 2,205 Ib Ib 0,454 kg
180 mbar 0,0145 2,61 PSI 2,61 PSI 68,95 180 mbar
6 m3/min 35,31 211,8 ft3/min 211,8 ft3/min 0,0283 6 m3/min
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
7
ND rangeCast aluminium blower housings, impellers made ofgalvanised steel sheet, maintenance-free squirrel cagerotor motors to IP 54. The blowers can be supplied inclockwise or anti-clockwise rotation. On demand speedvariable execution, 2-step speed variable, stepless withsingle phase, or speed variable execution by frequencyconverter. A variety of accessories include fine filters,connectors and throttle valves, base plate, etc.Special designs for specific applications, e. g. for highermedia flow and ambient temperatures, with improvedcorrosion protection, with sealed housing parts, for spe-cial voltage and frequency as well as to enclosure IP 55and thermal class F
3
LOW PRESSURE BLOWERS ND
Applications:• Conveying of high air volumes at low and
medium system resistance• Extracting fumes and vapours• Cooling apparatus and machinery parts• Ventilation of rooms• Chimney draft boosting• Forced air supply for gas, oil and coal fired systems• Drying parts of various size and composition• Supplementary cooling of electric machines
For more details see ND catalogue.
0
200
400
600
800
1000
1200
1400
1600
1800
2000
10 20 30 40 50 60 70 80 90 100
D 09
D 08
D 066 D 092
D 082
D 07
D 072
D 064 M
D 060 M
0
100
200
300
400
500
600
2,5 5 7,5 10 12,5 15 17,5
D 052 M
D 045 M
D 04 M
E 02 SP
D 05 M
D 03 M
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
6
LOW PRESSURE BLOWERS
4
ND
Twin blowersSame basic technical design and accessories as the standard blowers. All units are supplied without the foot base.
Compact blowersCast aluminium blower housings, impellers made ofgalvanised steel sheet. Compact dimensions by built-inmotors, cooled by the air flow through the blower. Theunits are supplied without a foot base and for clockwiserotation only (seen from the inlet side). Fine filters areavailable as an accessory.
0
100
200
300
400
500
600
700
800
900
1100
1000
1300
1200
1400
5 10 15 20 25 30 35 40
DK 3/2
DK 1/2
DK 2/2
0
200
400
600
800
1000
1200
1400
1600
1800
2000
10 20 30 40 50 60 70 80 90 100
2D08
2D 07
2D066
2D 064
2D 060
2D 052
2D 052D0452D04
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
5
RD rangeCast aluminium blower housings, impellers made ofgalvanised steel sheet, maintenance-free squirrel cagerotor motor to IP 54. The blowers can be supplied inclockwise or anti-clockwise rotation, with our withoutfoot base. On demand speed variable execution, 2-stepspeed variable, stepless with single phase, or speed variable execution by frequency converter. A variety ofaccessories include fine filters, connectors and throttlevalves, etc. Special blowers for specific applications,e.g. for higher media flow and ambient temperatures,with improved corrosion protection, with sealed housingparts, for special voltage and frequency as well as toenclosure IP 55 and thermal class F.
MEDIUM PRESSURE BLOWERS RD
Applications:• Conveying of medium air volumes at higher system
resistance• Ventilation of installations with higher system resistance• Air supply for drying installations• Air supply for air cushion tables• Air supply for filters and dust extraction
For more details see RD catalogue.
pp st
p
0
RD 94
20 40 60 80 100 140120
3000
11000
10000
6000
5000
4000
RD 92
RD 84
RD 8
RD 82
RD 72
RD 74
RD 7
RD 64
RD 65
2000
1000
7000
8000
9000
0
RD 62
RD 6
RD 0
RD 10
RD 14
RD 16
RD 2
RD 4
RD 5
2,5 5 7,5 10 12,5 15 20 22,5 25 3017,5 27,5
1000
3500
3000
2500
2000
1500
500
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
66
HIGH PRESSURE BLOWERSHRD
HRD rangeCast aluminium blower housings, closed impellers madeof sheet aluminium, maintenance-free squirrel cage rotormotors to IP 54. The blowers can be supplied in clockwi-se or anti-clockwise rotation. High performance by V-beltpulley drive at compact design. Special blowers for speci-fic applications, e. g. for higher media flow and ambienttemperatures, with improved corrosion protection, withsealed housing parts, for special voltage and frequency aswell as to enclosure IP 55 and thermal class F.Applications:• Conveying of medium air volumes at higher system
resistance• Vacuum operation• Forced air supply for gas, oil and coal fired systems• Air supply for drying installations• Air supply for air cushion tables
For more details see HRD catalogue
st
0
2000
4000
8000
9000
10000
11000
12000
5 10 15 20 25 30 35 40 45 50
HRD 2/4 T
HRD 2/5 T
HRD 60/4
HRD 60/77000
6000
5000
3000
1000
HRD 60/5
HRD 60/3
HRD 2/3 T
0
1000
3500
4000
4500
5000
5500
2,5 5 7,5 10 12,5 15 20 22,5 25 30
HRD 14/5 T3000
2500
2000
1500
500
HRD 14/4 T
HRD 14/3 T
HRD 14/2 T
HRD 1/2 T
HRD 1/3 T
HRD 1/4 T
HRD 1/5 T
17,5 27,5
st
0
2000
4000
8000
10000
12000
14000
16000
18000
10 20 30 40 50 60 70 80 90 100
HRD 65/2
HRD 65/4
HRD 65/5 HRD 65/7
HRD 7/12
HRD 7/17
HRD 7/23
6000
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
77
HIGH PRESSURE BLOWERS
Model range without motor This type of high-pressure fan can be driven from anexternal source via V-belts. The fan housings made of sturdy cast aluminium and the enclosed impellers aremanufactured from aluminium sheet. Fans are availablewith a clockwise or anti-clockwise rotation. A variety ofaccessories is also available. Special fans for special ope-rating conditions. e.g. increased temperatures of theconveyed medium and ambient temperatures, extendedcorrosion protection, fan sealing.
Model range for frequency converterFU/FUK series devices allow the infinitely variable speedregulation of the induction motors used. The speed canbe set from 0 to the max. possible speed typical for thedevice. No derating is required in the entire speed range.In the case of devices in the FUK series, the frequencyconverter is connected to the motor. The enclosure isIP54. The max. ambient temperature can range up to 60 degrees Celsius. Devices in the FU series require aseparate frequency converter, which is normally accom-modated in a switch cabinet. The types 1 T FUK-105/0,9to HRD 65 FUK-100/7,5 are deliverable with build up frequency converter.
HRD
st
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
10 20 30 40 50 60 70 80 90 100
HRD1T FU/FUK-0,9
HRD 14 T FU/FUK-2,1
HRD 2 T FU/FUK-2,7
HRD 60 FU/FUK-6,5
HRD 65 FU/FUK-6,5
HRD 65 FU/FUK-4,0
HRD 60 FU/FUK-4,0
HRD 7 FU/FUK-11
HRD 7 FU/FUK-15
HRD 7 FU/FUK-20
pp st
p
0
2000
4000
6000
8000
10000
12000
14000
16000
10 20 30 40 50 60 70 80 90 100
HRD 7
HRD 65
HRD 60
HRD 2 T
HRD 14 T
HRD 1 T
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
8
ELECTROR ORIGINAL ACCESSORIES
High performance noise protection systems.Due to design, all the fans from Elektror have a low noise level in proportion to their output. Extra noise protectionmeasures may be required in individual cases, however, depending on the purpose or also on statutory regulations. For these cases, Elektror offers a number of possibilities for active noise protection.
Disc sound absorbersAre manufactured exclusively from sheet steel in two piece execution. Elektror disc sound absorbers are fitted ex works with an integrated intake screen. Foam plastic is used as an insulation material in the large discs.
Tube sound absorbersExtremely high-performance sound deadening by meansof tubes, which are wound from aluminium foil and havea high tightness as a result of special folding. The insidetube is perforated and insulated with synthetic resin-bonded mineral fibre.
In addition, the tubes are tightly sealed with aluminiumcaps. This type of sound absorber can only be mountedwith an inlet connection without a flange.
Noise insulating coversThese covers are manufactured from sheet steel and cove-red with a rock wool insulation material, thereby provi-ding effective noise protection. The covers are mounted on a U-shaped base plate, which is suitable for screwing
on to a bed (drill holes are present ex works). The sidepanels can be easily detached and allow easy access tothe fan. All the noise insulating covers are designed forfitting to fans with free intake from the atmosphere.
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
9
SD rangeAll blower parts made of cast aluminium. Non-contact andoil-free rotating impellers. Silencers on inlet and outlet sidewith base plate as standard. Maintenance-free and perfor-mance-adapted squirrel cage rotor motors to IP 54.Various accessories as connectors, welding and threadedflanges, fine filters, pressure and vacuum relief valves andsupplementary silencers are available. Reversing units“Reversierautomat” for quick reversal of the air flow fromvacuum to pressure operation, with or without neutralposition, without reversing the direction of motor rotation.
SD high Pressure rangeSame basic technical design and accessories as SD range.
SIDE CHANNEL BLOWERS SD
0 0,5 1,0 3,01,5
100
300
250
350
200
2,0 3,52,5 5,04,0
SD 6
SD 54
SD 52
SD 5
SD 42
SD 4n
SD 2n
SD 22
SD 24SD 20
SD 12SD 12B
150
50
4,5
0 2 4 126
100
450
400
150
50
300
350SD 140
200
250
SD 120
SD 92
SD 9
SD 90
SD 80
SD 8
SD 82
SD 7
SD 72
SD 62
SD 64
SD 74
8 1410 201816 0 2 4 126
100
600
400
300
500
SD 820
200 SD 900
8 1410 1816
SD 420
SD 540
SD 800
SD 740SD 3
SD 6400
SD 5400
SD 400
SD 6200
SD 5200
SD 600
Tota
l pre
ssu
re r
ise
∆pt
(mb
ar)
Flow volume (m3/min)
Tota
l pre
ssu
re r
ise
∆pt
(mb
ar)
Flow volume (m3/min)
Tota
l pre
ssu
re r
ise
∆pt
(mb
ar)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
10
SIDE CHANNEL BLOWERSSD
Model range without motorThis type of appliance can be driven from an externalsource via V-belts. The fan housings made of sturdy castaluminium and the enclosed impellers are manufacturedfrom aluminium sheet. Fans are available with a clockwi-se or anti-clockwise rotation. A variety of accessories isalso available. Special fans for special operating condi-tions. e.g. increased temperatures of the conveyedmedium and ambient temperatures, extended corrosionprotection, fan sealing. For more details see SD catalogue.Applications:• Conveying of small to medium air volumes
at high system resistance • Air tube conveying • Vacuum lifting gear • Pneumatic conveying • Water treatment • Welding fume extraction • Vacuum cleaners
Model range for frequency converterFU/FUK series devices allow the infinitely variable speedregulation of the induction motors used. The speed canbe set from 0 to the max. possible speed typical for thedevice. No derating is required in the entire speed range.In the case of devices in the FUK series, the frequencyconverter is connected to the motor. The enclosure isIP54. The max. ambient temperature can range up to 60 degrees Celsius. Devices in the FU series require a separate frequencyconverter, which is normally accommodated in a switchcabinet.
0 2 4 126
100
400
300
500
200
SD 9-1
8 1410 1816
SD 8-1
SD 7-1
SD 6-1
SD 4n-1
SD 2n-1
SD 3-1
0 2 4
100
300
400
200
86 1210
SD 5 FU/FUK
SD 4n FU/FUK
SD 22 FU/FUK
SD 7 FU/FUK
Tota
l pre
ssu
re r
ise
∆pt
(mb
ar)
Flow volume (m3/min)
Tota
l pre
ssu
re r
ise
∆pt
(mb
ar)
Flow volume (m3/min)
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
FD/RD F
FD rangeBlower housings made of abrasion resistant cast iron,hinged housing cover lid for inspection and cleaning,welded sheet steel impellers with radial blades.Maintenance-free squirrel cage rotor motors to IP54.The units can only be supplied in the housing positionpictured. Accessories: Various connectors for both inletand outlet side. For more details see FD catalogue.Application:• Conveying of plastic granules, plastic waste and
lightweight bulk materials of all kind provided there is no operational risk.
RD F rangeThe RD F range can be used for conveying of light andnon-abrasive bulk. The blower parts are made of alumi-nium cast, the impellers are made of welded sheet steel.The solid construction of the practically maintenancefree medium pressure blowers is the basis for a longlasting service life and low operation cost. Inspectionand cleaning may only be carried out at these blowersby unscrewing the housing cover plate. All drive motors are made to IP 54 enclosure, class Fthermal insulation and comply with EN 60034-1 (VDE530 Part 1). The motor power is oversized in order tohave sufficient reserve for the conveying.For more details see FD / RD F catalogue.Application:• Conveying of lightweight bulk material of all kind
provided there is no operational risk.
CONVEYING BLOWERS
0
RD 82 F
10 20 30 40 50 7060
1500
7000
6500
3500
2500
2000RD 74 F
RD 62 F
RD 6 FRD 14 F
RD 4 F1000
500
4500
5000
5500
RD 5 F
3000
4000
6500
RD 64 F
0
500
1500
2000
2500
3500
3000
4000
10 20 30 40 50 60 70
FD 74
FD 72
FD 62
FD 64
1000
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
Pres
sure
ris
e ∆p
st(P
a)
Flow volume (m3/min)
11
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
Richard-Hirschmann-Straße 12 D-73728 Esslingen/NeckarPhone +49 (0) 711 319 73 –0Fax +49 (0) 711 319 73 –135Internet: www.elektror.de E-Mail: [email protected]
T 70
0418
03.
05/0
5 Ro
https://elektror.ru АО "БЕРГАБ" Тел./факс: (495)727-22-72 [email protected]
Top Related