AL - 5
Level measurement – Radar
Contents Page
Application examples ........................................ 6
VEGAPULS series 40 ....................................... 7 ff.
VEGAPULS series 50 ....................................... 14 ff.
Dimensions ....................................................... 22 ff.
VEGADIS 50, MINICOM .................................... 32
Level measurement – Radar
6 - AL
Level measurement – Radar
Continuous measurement withcompact instrument
Measuring system with VEGAPULS series 40 or50K as compact instrument
A measuring system consists of:
- one VEGAPULS series 40 or 50Kcompact instrument for use in non-Exarea with analgoue current output
HART® andVEGACONNECT
Power supply4 … 20 mA
VVO adjustmentprogram
Application examples: Level measurement with radar
Measuring system with VEGAPULS series 40 or50 as compact instrument Ex "d"
A measuring system consists of:
- one VEGAPULS 41 … 45 compactsensor or 51K … 56K two-wire sensorloop powered in Ex "d" version andpower supply via 4 … 20 mA
Continuous measurement withcompact instrument in hazardousareas
Ex-area Non-Ex-area
Zone 0
Ex-area Non-Ex-area
HART® andVEGACONNECT
Profibus PA ia or4 … 20 mA ialoop powered
Measuring system with VEGAPULS series 40 or50 as compact instrument intrinsically safe
A measuring system consists of:
- one VEGAPULS 41 … 45 compactsensor or 51K … 56K two-wire sensorloop powered with power supply via4 … 20 mA
- one VEGAPULS 41 … 45 compactsensor or 51K … 56K (two-wire sensorloop powered) intrinsically safe ia andsuitable separator, or
- one Profibus PA sensor VEGAPULS41 … 45 or 51P … 56P and a segmentcoupler for connection to Profibus DP/connection to PLC
VVOadjustmentprogram
Measuring system with VEGAPULS series 40 or50K as compact instrument
A measuring system consists of:
- one VEGAPULS series 40 or 50Kcompact instrument two-wire sensorloop powered with power supply via4 … 20 mA, or
- one Profibus PA sensor VEGAPULSseries 40 or 50P with digitaltransmission of measured values
HART® andVEGACONNECT
Profibus PA or4 … 20 mA loop powered
VVO adjustmentprogram
HART® andVEGACONNECT
4 … 20 mA loop powered
VVO adjustmentprogram
Measuring system with VEGAPULS series 40/50as compact instrument Ex "d" with separatepower supply
A measuring system consists of:
- one VEGAPULS 41 … 45 compactsensor or 51 … 56 four-wire sensorwith separate power supply in Ex "d"version and 4 … 20 mA current output
HART® andVEGACONNECT
4 … 20 mA
VVO adjustmentprogram
Power supply "e"
Ex-area Non-Ex-area
AL - 7
Level measurement – RadarVEGAPULS 41 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
VEGAPULS 41Radar sensor for continuous level measurement in 26 GHz technology with PTFE encapsulated antenna system Especially suitable for small vessels for the measurement of aggressive liquids under easy process conditions - wetted materials TFM™ -PTFE and PVDF with Viton seal- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm
´- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Meas. range : 10 mSeal antenna system : VitonProcess temperature : -40...130°CProcess pressure : -1...3 bar (-100...300 kPa)
Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)
CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)
CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)
DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)
XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 2)
DU FM Division 1/Zone 0, pressure-tight encapsulation 1)
Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Material G Thread G1½A/PVDFN Thread 1½NPT/PVDFA Tri-Clamp 2"/1.4571(316Ti)B Tri-Clamp 3"/1.4571(316Ti)J Bolting DN50/1.4571(316Ti) DIN11851L Bolting DN80/1.4571(316Ti) DIN11851
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT
PS41.
1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"
8 - AL
Level measurement – RadarVEGAPULS 42 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
VEGAPULS 42Radar sensor for continuous level measurement in 26 GHz technology with horn antenna Especially suitable for small tanks and process vessels for measurement of virtually all products - non-contact measurement, unaffected by process pressure, temperature and gas- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm
´- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Process pressure : -1...40 bar (-100...4000 kPa)
Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)
CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)
CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)
DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)
XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)
DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)
Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Material/Vessel pressure G Thread G1½A/1.4435(316L)(also antenna)/max.40barN Thread 1½NPT/1.4435(316L)(also antenna)/max.40bar
Horn antenna/Measuring range A ø40mm/max.10m
Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT
Options X withoutJ Extension for horn antenna 1.4435(316L)
PS42.
1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"
AL - 9
Level measurement – RadarVEGAPULS 43 radar sensor
ABILITY
WE'VE GOT
P R O F I
B U SPROCESS FIELD BUS
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
VEGAPULS 43Radar sensor for continuous level measurement in 26 GHz technology with PTFE encapsulated antenna systemEspecially suitable for measurement of liquids in the chemical, pharmaceutical and food processing industry - only one wetted material TFM™-PTFE- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm
`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module Process temperature : -40...150°CProcess pressure : -1...16 bar (-100...1600 kPa)
Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)
CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)
CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)
DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)
XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 2)
DU FM Division 1/Zone 0, pressure-tight encapsulation 1)
Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Measuring range FA Flange DN50PN40/10mFB Flange DN80PN40/20mFC Flange DN100PN16/20mAA Flange 2"150lb ANSI/10mAB Flange 3"150lb ANSI/20mAC Flange 4"150lb ANSI/20mAE Flange 6"150lb ANSI/20mCA Tri-Clamp 2"/10mCB Tri-Clamp 3"/10mRA Bolting DN50/10mRB Bolting 3"/10m
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT
PS43.
1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"
10 - AL
Level measurement – RadarVEGAPULS 44 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
VEGAPULS 44Radar sensor for continuous level measurement in 26 GHz technology with horn antenna Especially suitable for storage tanks and process vessels for the measurement of products such as solvents, hydrocarbons and fuels under arduous process conditions
- measurement up to 50 mm to the antenna edge for complete use of the vessel volume - accuracy +/- 3 mm
`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
Process pressure : -1...40 bar (-100...4000 kPa)
AL - 11
Level measurement – RadarVEGAPULS 44 radar sensor (continuation)
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)
CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)
CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)
DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)
XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)
DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)
Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Flange/Horn antenna/Measuring range/Material GCC DN50PN40C/ø48mm/max.15m/1.4435(316L)FCE DN80PN40C/ø75mm/max.20m/1.4435(316L)CCG DN100PN16C/ø95mm/max.20m/1.4435(316L)DCG DN150PN16C/ø95mm/max.20m/1.4435(316L)ARC 2"150lb RF,ANSI/ø48mm/max.15m/1.4435(316L)BRE 3"150lb RF,ANSI/ø75mm/max.20m/1.4435(316L)CRG 4"150lb RF,ANSI/ø95mm/max.20m/1.4435(316L)DRG 6"150lb RF,ANSI/ø95mm/max.20m/1.4435(316L)
Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT
Options X withoutJ Extension for horn antenna/1.4435(316L)
PS44.
1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"
12 - AL
Level measurement – RadarVEGAPULS 45 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
VEGAPULS 45Radar sensor for continuous level measurement of liquids in 26 GHz technology with mounted ¾" standpipe Especially suitable for the measurement of solvents and liquid gases in vessels with small process connections under arduous process conditions
- setup without additional settings- measurement up to the process fitting for complete use of the vessel volume - accuracy +/- 3 mm
`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
Process pressure : -1...40 bar (-100...4000 kPa)
AL - 13
Level measurement – RadarVEGAPULS 45 radar sensor (continuation)
• Multi-sectional standpipe upon request• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Approval XX withoutCX ATEX II 1G, 1/2G EEx ia IIC T6 2)
CM ATEX II 1G, 1/2G EEx ia IIC T6 + ship approvalDX ATEX II 1/2G EEx d ia IIC T6 1)
CA ATEX II 1G, 1/2G EEx ia IIC T6 + WHG 2)
DA ATEX II 1/2G EEx d ia IIC T6 + WHG 1)
XV FCCXU FM Division 2/Zone 2CU FM Division 1/Zone 0 FCC 2)
DU FM Division 1/Zone 0, FCC; pressure-tight encapsul. 1)
Electronics B Four-wire 20...72VDC/20...250VAC 4...20mA HART®D Two-wire-Loop powered 4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Material GB Thread G1½A/1.4435(316L)NR Thread 1½NPT/1.4435(316L)AC Flens DN50PN40C/1.4435(316L)BC Flens DN80PN40C/1.4435(316L)CC Flange DN100PN16C/1.4435(316L)DC Flange DN150PN16C/1.4435(316L)AR Flange 2"150lb RF,ANSI/1.4435(316L)BR Flange 3"150lb RF,ANSI/1.4435(316L)CR Flange 4"150lb RF,ANSI/1.4435(316L)DR Flange 6"150lb RF,ANSI/1.4435(316L)
Seal antenna system/Process temperature V Viton/-25...150°C/impedance cone PTFEN Viton/-40...150°C/impedance cone PTFEA Kalrez 4079/-15...150°C/impedance cone PTFE
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPT
PS45.
1) Only in conjunction with housing/cable entry "D"2) Not for electronics "B"
Standpipe length in mm per 100 mm of 1.4435(316L)per 100 mm of Hastelloy C22
14 - AL
Level measurement – RadarVEGAPULS 51 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
• Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
VEGAPULS 51Radar sensor for continuous level measurement of liquids in 6.3 GHz technology with rod antenna Especially suitable for vessels with small process connections for measurement of liquids under easy process conditions
- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
Meas. range : up to 20 m
Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA
Approval .X FTZ (Standard telecommunication approval)
EX0.X Use in Ex-Zone 0 1)
EX0.A Use in Ex-Zone 0, overfill protection WHG 1)
EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Process pressure G Thread G1½A/PVDF/max.3bar (PP antenna)N Thread 1½NPT/PVDF/max.3bar (PP antenna)E Thread G1½A/1.4435(316L)/max.16bar (PPS antenna)H Thread 1½NPT/1.4435(316L)/max.16bar (PPS antenna)A Tri-Clamp 2"/1.4571(316Ti)/max.3 barB Tri-Clamp 3"/1.4571(316Ti)/max.3 barJ Bolting DN50/1.4571(316Ti)/DIN11851/max.3 barL Bolting DN80/1.4571(316Ti)/DIN11851/max.3 bar
Rod antenna material/Process temperature 5 PP socket length up to 50mm/-20...80°C3 PPS socket length to 100mm/-20...120°C9 PPS socket length to 250mm/-20...120°C
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5
PULS51
1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"
AL - 15
Level measurement – RadarVEGAPULS 52 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
• Process connection "A", "B", "G", "N", "J", "L": only for socket length up to 50 mm• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA
Approval .X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0 1)
EX0.A Use in Ex-Zone 0, overfill protection WHG 1)
EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Process pressure/Temperature G Thread G1½A/PVDF/max.3 bar/-40...130°CN Thread 1½NPT/PVDF/max.3 bar/-40...130°CE Thread G1½A/1.4571(316Ti)/max.16 bar/-40...150°CH Thread 1½NPT/1.4571(316Ti)/max.16 bar/-40...150°CA Tri-Clamp 2"/1.4571(316Ti)/max.3 bar/-40...150°CB Tri-Clamp 3"/1.4571(316Ti)/max.3 bar/-40...150°CJ Bolting DN50/1.4571(316Ti)/max.3 bar/-40...150°CL Bolting DN80/1.4571(316Ti)/max.3 bar/-40...150°C
Rod antenna of PTFE 5 for socket length up to 50mm3 for socket length up to 100mm9 for socket length up to 250mm
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5
PULS52
1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"
VEGAPULS 52Radar sensor for continuous level measurement of liquids in 6.3 GHz technology Especially suitable for vessels with small process connections for measurement of aggressive liquids under easy process conditions
- rod antenna of PTFE (Teflon)- accuracy +/- 10 mm
`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
Meas. range : up to 20 m
16 - AL
Level measurement – RadarVEGAPULS 53 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
VEGAPULS 53Radar sensor for continuous level measurement of liquids in 6.3 GHz technology with rod antenna of PTFE Especially suitable for measurement of aggressive liquids under arduous process conditions
- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
Meas. range : up to 20 mProcess pressure : -1...16 bar (-100...1600 kPa)
AL - 17
Level measurement – RadarVEGAPULS 53 radar sensor (continuation)
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA
Approval .X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0 1)
EX0.A Use in Ex-Zone 0, overfill protection WHG 1)
EX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Process connection/Material C Flange DN50PN40C/1.4571(316Ti)D Flange DN80PN40C/1.4571(316Ti)G Flange DN100PN16C/1.4571(316Ti)H Flange DN150PN16C/1.4571(316Ti)S Flange 2"150lb ANSI/1.4571(316Ti)W Flange 3"150lb ANSI/1.4571(316Ti)P Flange 4"150lb ANSI/1.4571(316Ti)V Flange 6"150lb ANSI/1.4571(316Ti)
Rod antenna of PTFE/Process temperature 1 for measurement in standpipe/-40...150°C3 for socket length up to 100mm/-40...150°C9 for socket length up to 250 mm/-40...150°C
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5
PULS53
1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"
18 - AL
Level measurement – RadarVEGAPULS 54 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
VEGAPULS 54Radar sensor for continuous level measurement in 6.3 GHz technology with horn antenna and flange connection Especially suitable for measurement of liquids and solids under arduous process conditions such as buildup, condensation and foam generation as well as strong product movements
- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
AL - 19
Extension for horn antenna mm (max. 3000 mm); per 100 mm
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Level measurement – RadarVEGAPULS 54 radar sensor (continuation)
Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA
Approval .X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0 1)
EX0.A Use in Ex-Zone 0, overfill protection WHG 1)
EX0.M Use in Ex-Zone 0, ship approval GL, LREX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Flange size/Material/Antenna diameter RCX DN50PN40C/1.4571(316Ti)/without horn antennaUC6 DN80PN40C/1.4571(316Ti)/horn antenna ø76EC1 DN100PN16C/1.4571(316Ti)/horn antenna ø96FC2 DN150PN16C/1.4571(316Ti)/horn antenna ø146FD2 DN150PN16C/1.4571/PTFE-coat./enamelled antenna ø140 3)
MD4 DN200PN16C/1.4571/PTFE-coat./enamelled antenna ø160 3)
SVX 2"150lb RF/1.4571(316Ti)/without horn antennaWV6 3"150lb RF/1.4571(316Ti)/horn antenna ø76PV1 4"150lb RF/1.4571(316Ti)/horn antenna ø96VV2 6"150lb RF/1.4571(316Ti)/horn antenna ø146VD2 6"150lb RF/1.4571/PTFE coat./enamelled antenna ø140 3)
QD4 8"150lb RF/1.4571/PTFE coat./enamelled antenna ø160 3)
Seal antenna system/Process temperature V Viton/-25...150°CA Kalrez 4079/-15...150°CP Viton with PTFE-coating/-40°C...200°C 5)
G Graphite with ceramic/-60...250°C
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5
Options X withoutJ Extension for horn antenna/1.4571(316Ti) 4)
PULS54
1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"3) Delivery time more than 10 working days4) Delivery time more than 5 working days5) Only possible with antenna material enamel
20 - AL
Level measurement – RadarVEGAPULS 56 radar sensor
ABILITY
WE'VE GOTP R O F I
B U SPROCESS FIELD BUS
VEGAPULS 56Radar sensor for continuous level measurement in 6.3 GHz technology with horn antenna and flange connection under high pressures and temperatures Especially suitable for measurement of liquids and solids under extreme process conditions such as 160 bar (16000 kPa) process pressure or 400°C process temperature
- accuracy +/- 10 mm`- ECHOFOX® signal processing with Fuzzy-Logic- adjustment via VEGACONNECT and PC, via detachable adjustment module
AL - 21
Extension for horn antenna mm (max. 3000 mm); per 100 mm
• Further process connections upon request• Profibus accessory see chapter "Signal conditioning instruments and communication"
Level measurement – RadarVEGAPULS 56 radar sensor (continuation)
Instrument version K Compact instrument with analogue current outputP Digital signal transmission for connect. to Profibus PA
Approval .X FTZ (Standard telecommunication approval)
EX0.X Use in Ex zone 0 1)
EX0.A Use in Ex-Zone 0, overfill protection WHG 1)
EX0.M Use in Ex-Zone 0, ship approval GL, LREX.U FM Div.I, CSA Div.I, FCC, Industry Canada 2)
.U FM Div.II, CSA Div.II, FCC, Industry Canada
Electronics D Two-wire-Loop powered/4...20mA HART®B Four wire 20...72VDC,20...250VAC/4...20mA HART®G Profibus PA
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
Flange size/Material/Antenna diameter RCX DN50PN40C/1.4571(316Ti)/without horn antennaUC6 DN80PN40C/1.4571(316Ti)/horn antenna ø76EC1 DN100PN16C/1.4571(316Ti)/horn antenna ø96FC2 DN150PN16C/1.4571(316Ti)/horn antenna ø146SVX 2"150lb RF/1.4571(316Ti)/without horn antennaWV6 3"150lb RF/1.4571(316Ti)/horn antenna ø76PV1 4"150lb RF/1.4571(316Ti)/horn antenna ø96VV2 6"150lb RF/1.4571(316Ti)/horn antenna ø146
Seal antenna system/Process temperature G Graphite (coupling of ceramic)/-60...400°C
Housing/Cable entry K Plastic PBT/M20x1,5N Plastic PBT/½NPTA Alu powder coated/M20x1,5D Alu powder coated EEx d/½NPTE Alu powder coated EEx e/M20x1,5
Options X withoutJ Extension for horn antenna/1.4571(316Ti) 3)
PULS56
1) In combination with electronics "B": only in conjunction with housing/cable entry "D" or "E"2) In combination with electronics "B": only in conjunction with housing/cable entry "D"3) Delivery time more than 10 working days
22 - AL
Level measurement – RadarDimensions
VEGAPULS 41, 42 and 43
Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment
VEGAPULS 43
215
185
370
205
185
215
370
205
116 25 11625
M20x1,5
½ NPT
201
10˚ 101
125
182
322
M20x1,5
165
135
G1½ A1½ NPT
ø 40
100 14
5 199
ø
G1½ A1½ NPT
420
9ø 60,3
ø 102
84
ø 125
18
ø 165
DN 50 PN 40 C DN 80 PN 40 C
45
ø 160
ø 200
18
ø 138
142
414
24
ø 40
SW 60 SW 60
130
83
VEGAPULS 42VEGAPULS 41
AL - 23
Level measurement – RadarDimensions
Recommended max. socket lengthdepending on the antenna version:
Sensor type Version Socket length
VEGAPULS 41 Standard 70 mmVEGAPULS 42 Standard 135 mmVEGAPULS 43 DN50/ANSI 2" 50 mm
DN 80/ANSI 3" 80 mmDN 100/ANSI 4" 100 mmDN 150/ANSI 6" 150 mmTri-Clamp 2" 50 mmTri-Clamp 3" 80 mmTri-Clamp 4" 100 mm
VEGAPULS 43
DN 100 PN 16 C
ø 180
ø 220
45
ø18
ø 157,2
414
20
DN 150 PN 16 C
ø 240
ø22
ø 285
45
ø 212
414
22
Tri-Clamp 2" Tri-Clamp 3" Tri-Clamp 4"
169
14 ø 119
105
ø 648 ø 918
0,3
24 - AL
Level measurement – RadarDimensions
VEGAPULS 44 and 45
VEGAPULS 44
215
185
370
205
185
215
370
205
116 25 11625
M20x1,5
½ NPT
201
10˚ 101
125
182
322
M20x1,5
165
135
ø 160
ø18
ø 200
45˚
DN 80 PN 40 C
24
ø 75
219
ø 180
ø 220
45˚
ø18
ø 95
DN 100 PN 16 C
2031
9
ø 240
ø22
ø 285
45˚
ø 95
DN 150 PN 16 C
2231
9
ø 125
ø18
ø 165
DN 50 PN 40 C
1920
139
ø
ø 40
PB
T: 5
3A
l: 73
ø 26,9
L16
Antenna extension
Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment
AL - 25
Level measurement – RadarDimensions
VEGAPULS 45
Recommended max. socket lengthdepending on the antenna version:
Sensor type Version Socket length
VEGAPULS 44 DN50/ANSI 2" 135 mmDN 80/ANSI 3" 210 mmDN 100/ANSI 4" 310 mmDN 150/ANSI 6" 310 mm
DN 50…DN 150 PN 16/40 C G1½ A1½ NPT
18…
22
ø165…285
L m
ax. 4
000
125
65
ø 27
22
29
ø 27
L m
ax. 4
000
125
ø 26,9 x 2,6
x
1545
1000
Extension sleeve formulti-sectionalstandpipe
26 - AL
Level measurement – RadarDimensions
VEGAPULS 51 … 53
20
24
ø60
ø85
212
350
382
(532
)
ø25ø40
ø35
415
(565
)
ø36
PB
T: 6
42 (
792)
Al:
66
5 (8
15)
PB
T: 6
09 (
759)
Al:
6
32 (
782)
PB
T: 5
77
Al:
600
SW 60
215185
370
205
185
215
370
205
11625 116
25
M20x1,5
½ NPT
201
10˚ 101
125 135
182
322
M20x1,5
165
7
80
ø
202
112
PB
T: 3
95A
l:41
7
ø104
DN 50 PN 40 C
ø125
ø165
ø18
G 1½ A1½ NPT
G 1½ A1½ NPT
G 1½ A1½ NPT
VEGAPULS 51Antenna PP
VEGAPULS 52Antenna PTFE
VEGAPULS 52
VEGAPULS 53
for standpipe
VEGAPULS 51Antenna PPS
Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment
AL - 27
Level measurement – RadarDimensions
2
ø158
DN 100 PN 16 C
ø180
2
20
ø138
ø18
ø104
DN 50 PN 40 C
ø160ø125
2
2420
ø35
395
(545
)
ø36
ø35
ø36
ø35
395
(545
)
PB
T: 6
79 (
879)
Al:
7
02 (
852)
ø36
395
(545
)
ø220ø200
DN 80 PN 40 C
ø165
PB
T: 6
79 (
879)
Al:
70
2 (8
52)
PB
T: 6
77 (
827)
Al:
700
(85
0)
45˚
ø18
45˚
ø18
80 222
ø35
395
(545
)
PB
T: 6
81 (
881)
Al:
70
4 (8
54)
ø36
ø240
ø22
DN 150 PN 16 C
ø285
ø216
45˚
VEGAPULS 53
28 - AL
Level measurement – RadarDimensions
VEGAPULS 54
ø 144ø 212
ø 162ø 268
242
30 1
96
22
ø 240
ø 285
PBT:
483
Al:
531
PBT:
535
Al:
583
ø22
45˚
ø22
ø 295
ø 340
45˚
DN 150 PN 16 C DN 200 PN 16 C
ø160
ø76
ø18
ø125
ø18
242026
DN 50 PN 40 C DN 80 PN 40 C
ø200
75
ø165
45˚
PB
T: 2
76 (
250˚
C: 3
99)
Al:
3
19 (
250˚
C: 4
42)
215185
370
205
185
215
370
205
11625 116
25
M20x1,5
½ NPT
201
10˚ 101
125 135
182
322
M20x1,5
165
196
176
53 73
PB
T: 3
30 (
250˚
C: 4
53)
Al:
3
73 (
250˚
C: 4
96)
PBT Alu
53 73
PBT Alu PBTV4A
AluV4A
Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment
AL - 29
Level measurement – RadarDimensions
2220
5
ø146
ø240
ø22
DN 150 PN 16 C
ø285
2429
6
ø196
2638
0
ø242
45˚
ø26
2012
0
ø180
ø96
DN 100 PN 16 C
ø220
45˚
ø18
DN 200 PN 16 C DN 250 PN 16 C
PB
T: 4
62 (
250˚
C: 5
85)
Al:
5
05 (
250˚
C: 6
28)
ø295
ø22
ø340ø355
ø405
30˚
30˚
PB
T: 3
75 (
250˚
C: 4
98)
Al:
4
18 (
250˚
C: 5
41)
PB
T: 6
41 (
250˚
C: 7
64)
Al:
6
84 (
250˚
C: 8
07)
PB
T: 5
55 (
250˚
C: 6
78)
Al:
5
98 (
250˚
C: 7
21)
30 - AL
Level measurement – RadarDimensions
VEGAPULS 56
320
2012
0
ø180
ø96
ø160
ø76
ø18
ø125
ø18
242026
DN 50 PN 40 C DN 80 PN 40 C DN 100 PN 16 C
ø200
75
ø220ø165
45˚
45˚
ø18
PB
T: 5
43A
l:
566
215185
370
205
185
215
370
205
11625 116
25
M20x1,5
½ NPT
201
10˚ 101
125 135
182
322
M20x1,5
165
PB
T: 6
42A
l:
665
PB
T: 5
97A
l:
620
Plastic housing Aluminium housing Aluminium housing with Ex dterminal compartment
AL - 31
Level measurement – RadarDimensions
ø26
ø295
ø22
ø340ø355
ø405
30˚
30˚
2220
5
ø146
ø240
ø22
DN 150 PN 16 C
ø285
2429
6
ø196
2638
0
ø242
45˚
PB
T: 7
29A
l:
752
DN 200 PN 16 C DN 250 PN 16 C
PB
T: 9
08A
l:
931
PB
T: 8
22A
l:
845
32 - AL
Level measurement – RadarAdjustment instruments and accessory for setup of sensors
• Dimensions see chapter "Indication and adjustment"
VEGADIS 50External indication and adjustment unit for connection of VEGAPULS series 40 and 50, VEGASON 50 and VEGAFLEX 50 sensorsSuitable for external indication of the measured values and external adjustment of sensors
- digital and quasi-analogue indication of measured values- can be mounted up to 25 m away from the sensor - module for adjustment module MINICOM
Indicating range : -9999...9999, with individually adjustable decimal point
Housing protection : IP66/IP67
Approval EX.X ATEX II 1 G EEx ia IIC T6
Adjustment module MINICOM (plug-in) X withoutB mounted
Indication X withoutA mounted
DIS50
MINICOMPluggable adjustment module for VEGASON, VEGAPULS and VEGAFLEX series 50 and VEGAPULS series 40 sensorsSuitable for adjustment directly on the sensor or separate in conjunction with VEGADIS 50 for 4...20mA or Profibus PA sensors
- 6-key adjustment´- 4-line display for menu-driven clear text parameter adjustment
MINICOM.