LEDs

• Switch Chassis LEDs, page 1

• Uplink Module LEDs, page 2

• Fan Module LEDs, page 2

• Power Supply LEDs, page 2

Switch Chassis LEDsThe BCN, STS, and ENV LEDs are located on the left side of the front of the switch. The port LEDs areappear as triangles pointing up or down to the nearest port.

StatusColorLED

The operator has activated this LED to identify this module in the chassis.Flashing blueBCN

This module is not being identified.Off

The switch is operational.GreenSTS

The switch is booting up.Flashing amber

Temperature exceeds major alarm threshold.Flashing red

The switch is not receiving power.Off

Fans and power supply modules are operational.GreenENV

At least one fan or power supply module is not operating.Amber

Port is connected with a transceiver or other connector.Green(port)

Port is not connected.Amber

Cisco Nexus 9396PX NX-OS-Mode Switch Hardware Installation Guide 1

Page 2: LEDs - Cisco...LEDs • SwitchChassisLEDs,page1 • UplinkModuleLEDs,page2 • FanModuleLEDs,page2 • PowerSupplyLEDs,page2 Switch Chassis LEDs TheBCN,STS ...

Uplink Module LEDsThe Status (STS) LED is located on the left side of the uplink module. There is an ACT LED located beloweach two uplink ports. Next to each ACT LED are two triangular port LEDs that point to the top or bottomto identify their port as being the top or bottom port.

Table 1: Uplink Module LED Descriptions

StatusColorLED

This module is operational.GreenSTS

Temperature is not operational.Red

The module is not receiving power.Off

The two ports above this LED are enabled.On (white)ACT

The two ports above this LED are not enabled.Off

The port is connected with a transceiver or other connector.Green(port)

The port is not connected.Off

Fan Module LEDsThe fan module LED is located below the air holes on the front of the module.

StatusColorLED

The fan module is operational.GreenSTS

The fan module is not operational (fan is probably not functional).Red

Fan module is not receiving power.Off

Power Supply LEDsThe power supply LEDs are located on the left front portion of the power supply. Combinations of states

indicated by the Okay ( ) and Fault ( ) LEDs indicate the status for the module as shown in the followingtable.

Cisco Nexus 9396PX NX-OS-Mode Switch Hardware Installation Guide2

LEDsUplink Module LEDs

Page 3: LEDs - Cisco...LEDs • SwitchChassisLEDs,page1 • UplinkModuleLEDs,page2 • FanModuleLEDs,page2 • PowerSupplyLEDs,page2 Switch Chassis LEDs TheBCN,STS ...

Table 2: Power Supply LED Descriptions

Status LED LED

Power supply is on and outputting power to the switch.OffGreen

Power supply is connected to a power source but not outputting power to theswitch—power supply might not be installed in the chassis.

OffFlashinggreen

Power supply is not receiving power.OffOff

Power supply warning—possibly one of the following conditions:

• High voltage

• High power

• Low voltage

• Power supply installed in chassis but not connected to a power source

• Slow power supply fan

Flashingamber

Green

Power supply failure—possibly one of the following conditions:

• Over voltage

• Over current

• Over temperature

• Power supply fan failure

AmberFlashinggreen

Cisco Nexus 9396PX NX-OS-Mode Switch Hardware Installation Guide 3

LEDsPower Supply LEDs