Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 1

Kinetic Backup Power for SRCF Bob Hall, Senior Manager, Applications Engineering

Kit Killingsworth, System Sales Engineer

Page 2: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 2

Agenda» Introductions

» Phil Reese’s Vision

» Who is Active Power Products Product value proposition

» The 415 VAC Data Center One Line Advantages to drive lower PUE Air side economizing

» Technology Flywheel energy storage UPS parallel online topology TCO

Page 3: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 3Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 3

A Simple Idea and Vision

» The vision of a single man can be a powerful, driving factor

» The vision of Stanford to explore alternative solutions for their data center in both power and cooling

Page 4: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 4Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 4

Who is Active Power?» Active Power is a leading global manufacturer of

uninterruptible power supply (UPS) systems and modular infrastructure solutions for data centers and other mission critical operations

» Our products and services provide tangible operational advantages through an unmatched combination of power density, reliability, and total cost of ownership

» Chosen by marquee customers around the world, we help them achieve their most forward thinking data center designs

Global Customers

Page 5: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 5

Company Snapshot» Overview

Founded 1992; IPO 2000 NASDAQ: ACPW 23% average annual growth

since 2005 57 country implementations 3,800+ flywheels shipped 160+ million hours of field

runtime 900 MW power protection

deployed

» Innovation Patented flywheel technology 100+ global patents issued

» Global Operation Centers Austin, Texas (HQ) UK Germany China

» Capabilities 9001:2008 ISO Manufacturing Packaging & Integration Services Design & Project Management Installation & Maintenance

» Partners

Page 6: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 6Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 6

The Data Center Paradigm Shift to 415 VAC

Page 7: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 7Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 7

» MV – LV Transformation at UPS 5KV / 415V transformer feeds UPS 415V in/out of UPS Single phase 230V distributed

server racks

» Benefits Transform close to load still allows

benefits of small MV cabling Eliminate PDU transformer cost

and efficiency losses Reduce footprint of many PDUs

The 415V Data Center

1250KVA5KV415VY/230V

PDU A1250KVA

1000 KVA900KW

CDB A 415/230V

Page 8: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 8Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 8

4MW UPS project, expandable to 8 MW

» Capex Reduced wiring cost by $250,000 dollars (14% of total installation) by

providing MV as close to the load (point of transformation) as possible Eliminate 480:208V transformers in PDUs Reduced MV breakers by $360,000 (11% of total hardware) Reduced UPS / PDU space consumption by 50%

» Opex Improve efficiency by 2-3% by eliminating transformation steps ($65,000

annual savings @ 3MW; $171,000 annual savings @ 8MW) Improve power supply (server) efficiency by 1.5-2% operating at higher

voltage ($42,000 annual savings @ 3MW; $112,000 @ 8MW) Total annual savings of $239,000 @ 3MW; $635,000 @ 8MW) Lower losses = less cooling required

Major Savings in MV / 415V Distribution

Page 9: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 9

SRCF Abbreviated SLD

G

2.5MW12.47kV

1000kVA/900kW

Active PowerFlywheel

UPS

1000kVA/900kW

Active PowerFlywheel

UPS

1000kVA/900kW

Active PowerFlywheel

UPS

G

2.5MW12.47kV

Page 10: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 10Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 10

PUE – Power Usage Effectiveness

How PUE is changing the topologies, functions, and characteristics of UPS in the data center space

10

PUE = Total Facility PowerIT Equipment Power

Page 11: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 11Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 11

More on PUE» Power usage effectiveness (PUE) is a measure of how efficiently a

data center uses its power; specifically, how much of the power is actually used by the computing equipment

» PUE is the inverse of data center infrastructure efficiency (DCIE).

» An ideal PUE is 1.0

» Anything that isn't considered a computing device in a data center (i.e., lighting, cooling, etc.) falls into the category of facility power usage

11

Page 12: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 12Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 12

Value Propositions to Drive Lower PUE» Medium Voltage Application

» Highly Efficient, Up to ~98%

» Minimal if any AC needed for the UPS, will operate up to 104 F without de-rating

» Half the heat rejection of legacy UPS

» No special room needed – less construction cost

» Power Dense – twice the power in half the space

» Lower overall maintenance cost

» Air side economizing for facility

Page 13: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 13Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 13

Utility Savings of Highly Efficient UPS

Traditional Double Conversion UPS

$ / kW/hr. $ 0.10 0.1 X 0.06

X 2400 X 8760 = $ 134,194

kW load 2400 0.94

Traditional UPS Efficiency 94% Active Power CleanSource UPS

Active Power UPS Efficiency 97% 0.1 X 0.03X 2400 X 8760 = $ 65,022

0.97

Utility savings per year: $ 69,172

Page 14: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 14

UPS Technology and Product Overview to Achieve Lowest PUE and TCO

Page 15: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 15Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 15

Power Dense and Reliable» Modular * Scalable * Flexible» Field Upgradeable * Grows with IT and Business Needs» Paralleling Capability for Multi-Megawatt Solutions

300 kVA600 kVA 900 kVA

1200 kVA

Page 16: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 16Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 16

CleanSource UPS Multi-Module Systems – Z Series

Input Isolation SwitchesSystem Cabinet

Output Isolation SwitchesSystem Cabinet

Dual Input OptionMBP External Only

DC

DCAC

ACDC

DCAC

AC

MMS One-line

Built in:• Maintainability• Scalability• Redundancy

DC

DCAC

ACDC

DCAC

AC

Page 17: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 17

Flywheel UPS Parallel Online Architecture

Static Bypass

Harmonic Current• Conditions power to load• Voltage regulation• Power Factor correction• Harmonic cancellation

• Low input current distortion• Overload capability• Unlimited cycling

Page 18: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 18Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 18

Total Cost of Ownership (TCO) » Lower installation costs

Flywheel and communication cables as well as wire way provided

» Efficiency – up to 98%

» Minimal cooling requirements Less heat rejection

» Small footprint, power dense

» Low maintenance costs

» No battery cooling required

» No battery changes

» A KNOWN Energy Source

Page 19: Kinetic Backup Power for SRCF

Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 19