Download - igus in the cleanroom

Transcript
Page 1: igus in the cleanroom

..room/..

.de/..Sensational test results...Sensational test results...Sensatio

®

clean...

Page 2: igus in the cleanroom

This is the common objective for the de-velopment of all igus®-products. A new report of IPA, Fraunhofer Institut,proves the best possible classification ISOclass 1 for a large number of igus®-pro-ducts.

The single demand for all cleanroom products is that as fewparticles as possible should be released into the environ-ment. This is especially important for moving dynamic sys -tems, for example E-Chains® and cables. A high resistanceto wear results in less particles, as well as ensuring a long lifetime.

...class1.

Chainflex®-cables CF9, CF27, CF34 and pneumatic hose CF CleanAir IPA certified for ISO class 1By including all cables with the same outer jacket material there are resultsfor 620 different cables – available ex stock.

Best possible certified classification: E-Chain® series E3, E

E-Chains® Result

E3.15.040.075.0 ISO Class 1 E6.29.060.150.CR* ISO Class 1 E6.29.060.150.0 ISO Class 3 E14.3.038.0 ISO Class 2 2500.05.055.0 ISO Class 3 280.100 ISO Class 4 * Special Material CR

Chainflex® Result

CF5.10.07 ISO Class 2 CF9.15.07 ISO Class 1 CF34.25.04 ISO Class 1 CF27.07.05.02.01.D ISO Class 1 CAPE (CF Clean Air) ISO Class 1

Test results

E-ChainSystems® E3 and E6.CR IPA certified for ISO class 1Now there are precise statements for all common igus® E-Chains® for usein clean rooms.

Page 3: igus in the cleanroom

...class1.E6 + Chainflex® cables CF9, CF27 and CF34...Best possib

Class per DIN Equivalent to Equivalent to EN ISO 14644-1 VDI 2083 US Fed.Std. 209E

ISO Klasse 1 no compar. classification no compar. classificationISO Klasse 2 no compar. classification no compar. classificationISO Klasse 3 Class 1 Class 1ISO Klasse 4 Class 2 Class 10ISO Klasse 5 Class 3 Class 100ISO Klasse 6 Class 4 Class 1.000ISO Klasse 7 Class 5 Class 10.000ISO Klasse 8 Class 6 Class 100.000

Classification chart

Particle generation measurement:For 100 minutes the air that is extracted at the moving test object isanalysed for particles.

Result: As shown in the graph i.e. NO particles larger ≥ 0,2 µmwere measured.

0

1

2

3

10Measuring period [min]

Test results with igus® Chainflex® cable CF354.25.04, v1=0,5 m/s, E-Chain® E3.15.050.075.0 black

Par

ticle

> 0

,2 μ

m p

er m

in

20 30 50 60 70 80 90 10040

Test setup

Page 4: igus in the cleanroom

As well as clean room suitabi-lity, there is often a require-ment for ESD protection. Withthe E-Chain® Series "Easy-Chain®" made of igumid NB, arange of products are availableex stock which have the bestpossible ESD-compatibilityLevel 1 acc. to Semi E78-0998 certified by IPA.Also a large number of E-Chains® are available in ESD/ATEX-versionon request – with PTB certifcate. The ESD E-Chain® even has a longer life time than the standard ma-terial. When compared with the traditional solutions using temporary con-ductive layers or built in static inhibitors, the igus® options offer a longlasting and maintenance free conductivity. And additional advantageis the resistance to unfavourable environmental conditions.

.de/... igus® GmbH Spicher Str. 1a D-51147 Köln (Cologne)Phone +49-2203-9649-0 Fax [email protected] www.igus.de

MAT0071371.2 12/2007

esd...Field strength measurement

Test design

Result: Level 1, ESD-compatibility acc. to SEMIE78-0998, for E14.3.038.0 and E6.29.050.055.0

There is a large range of electrically conductive iglidur® polymer bear-ing materials. I.e. the high-tech problem solver iglidur® X with a spe-cific volume resistance <105 Ωcm and a surface resistance < 103 Ω.Please request further iglidur®-materials and technical data for yourapllication!

..ESD & ATEX... maintenance-free conductivity...ESD & AT

..//electrical conductive polymer bearings...//electrical con

iglidur® F iglidur® H 370iglidur® X

®