iFaceSeriesInstallationGuide
Version1.0DateSep2009
AboutthisGuide
This guide provides actual installation instructions only. For information
regardinguserinstructions,pleaserefertoiFaceSeriesUserManual.
iFaceSeriesInstallationGuideV1.0
I
Content1SystemConfiguration.............................................................................. 1
1.1Viewofoperationpanel................................................................ 1
1.2Theillustrationofsystemconstruction .......................................... 2
1.3Thesketchmapofcommunication................................................ 3
2Installation.............................................................................................. 4
2.1Doorsensorconnection ............................................................... 6
2.2Exitbuttonconnection.................................................................. 6
2.3TimeRingconnection .................................................................. 7
2.4Doorlockconnection.................................................................... 8
2.5Ethernetconnection ................................................................... 12
2.6RS232connection...................................................................... 13
2.7RS485connection...................................................................... 14
2.8 WiegandOutputConnection....................................................... 15
2.9PowerConnection...................................................................... 16
3.Others ................................................................................................. 17
3.1Reset......................................................................................... 17
3.2 Antidismantlebutton.................................................................. 17
3.3Uflashdiskusing....................................................................... 18
3.4ReserveBattery......................................................................... 19
iFaceSeriesInstallationGuideV1.0
1
Powerkey
Resetkey
USB
Loudspeaker
Batteryslot
Touchscreen
Camera
Baseline
FingerprintSensor
LEDlight
1SystemConfiguration
1.1Viewofoperationpanel
Power TCP/IP USB
iFaceSeriesInstallationGuideV1.0
2
1.2Theillustrationofsystemconstruction
iFaceSeriesInstallationGuideV1.0
3
PC
PC
1.3Thesketchmapofcommunication
1FingerprintmachinedirectlyconnectswithPCthroughRS232orTCP/IP.
2FingerprintmachineconnectswithPCthroughRS485network.
3FingerprintmachineconnectswithPCthroughTCP/IPnetwork.
TCP/IP
TCP/IPTCP/IP
RS485Switch
RS232
RS485
Switch
TCP/IP orRS232
PC
iFaceSeriesInstallationGuideV1.0
4
Power TCP/IP USB
2Installation
Caution:Donottoconnectperipheralequipmentbeforethepowerof thedevice iscutdown,otherwise it ispossible todamagethedevicebadly.Pleasefollowinstructiontoconnectperipheralequipment Doorsensorconnection(Sensor,GND) Exitbuttonconnection(Button,GND) Alarmconnection(NC2,COM2,NO2) Doorlockconnection(NC1,COM1,NO1) Ethernetconnection(RJ451,RJ452,RJ453,RJ456) RS232connection(232T,232R,GND) RS485connection(485A,485B) Wiegandoutputconnection(WD0,WD1,GND) Powerconnection(+12V,GND)
iFaceSeriesInstallationGuideV1.0
5
Thedefinitionofterminalconnection
Fromlefttoright
1 NO2 ConnecttoCableBellNOterminal
2 COM2
ConnecttoCableBellCOMterminal
3 NC2 ConnecttoCableBellNCterminal
Tieup
together
4 Sensor
ConnecttoDoorsensor
5 GND ForDoorsensorandreleasebutton
6 Button
ConnecttoReleasebutton
Tieup
together
7 NO1 ConnecttoLockNCterminal
8 COM1
ConnecttoLockCOMterminal
9 NC1 ConnecttoLockNOterminal
Tieup
together
10 485 ConnecttoRS485B
11 485+ ConnecttoRS485A
Tieup
together
12 GND Connect to RS232 and WeigandGND
13 TXD ConnecttoRS232TXD
14 RXD ConnecttoRS232RXD
Tieup
together
15 WD0 ConnecttoWeigandoutWD0
16 WD1 ConnecttoWeigandoutWD1
17 SGND
Connectto screenwire
Tieup
together
18 GND ConnecttoPowerGND
19 +12V ConnecttoPower+12v
Tieup
together
iFaceSeriesInstallationGuideV1.0
6
2.1Doorsensorconnection
The door sensor is used to detect the door openclose state ,terminal can monitor if the door has been unauthorized openthroughthedoorsensor,atthistimeitcanoutputaalarmsignal,moreover, terminal can triggerpromptwarning if thedoor is notclosetightly.
2.2Exitbuttonconnection
Theexitbuttonisinstalledforindooroperation.Whentheswitchof the button is close, the door will open. The distance isapproximately1400mmfromgroundtoexitbuttonbottom. Makesurethattheexitbuttonpositionistoaligncorrect,uprightandtheconnection is accurate and reliable. (Unused exposed end ofcable should be cut off, and use insulating tape towrap it.)Payattentiontoelectromagneticdisturbance.(Forexample:Thelightswitch,thecomputerandsoon)
DoorSensor
Button
PowerSupply
iFaceSeriesInstallationGuideV1.0
7
2.3TimeRingconnection
Connecttheelectricalbelltothefingerprintmachine,when arrivethe
appointtime,thefingerprintmachinewillsendsignalto triggerrelayTheterminalsupportsbothNormalOpenbellsandNormalClosebellsatthesametime.NormalOpenbells
NormalClosebells
iFace
Bell
iFace
Bell
Powersupply
Powersupply
iFaceSeriesInstallationGuideV1.0
8
2.4Doorlockconnection
Thewayof installingdoor lockdependson the typeof lockandlocalcondition. Internal resistorwhichcomesfromlongdistancetransfer should be taken into consideration when selecting thecableofelectricpower.Thedoorlockshouldbeinstalledreliableandstable .Ensure thewiring is correct.For thestrike lockandelectromagnetic lock, you should pay attention to positive andnegativeterminalconnection.Theunusedbareendofwireshouldbe cut off and use insulating tape towrap it. The delay time ofstrikelockisadjustableaccordingtodifferentconditions.Select electric lockit is better to use strike lock for the twodirection opening glass door (both open to inside or outsidedirection),forthesingleopeningwooddoorincompanyinternal,werecommend tousemagnetic lock, themagnetic lockalsobecalled as electric magnetic lock,. The magnetic lock is morereliablethanthestrikelock,butthestrikelockismuchsaferthanthemagneticlock.Inthesmalllivingcommunity,itisbettertousestrikelockandmagneticforcelock.Theelectriccontrollockgivesout higher noise the electric control lock is commonly used tobuildingcommunication.Nowthereisasoundlesselectriccontrollockwhichisabletobeapplied.Pleasepayattention,thelockismadeofironandeasyrust,soyoumustbewareofnotexposingittowater or harsh condition, there are some other electric locksavailable,wedontrecommendyoutousethem.Connectwithelectriclock
The NormalOpen lock is open when the power is on. TheNormalClose lock is closed when power is on. The machine
iFaceSeriesInstallationGuideV1.0
9
supportsbothofthetwokindsoflocksatthesametime.Thewayoflockconnectionchangeswiththetypeoflock.ForNOlock,theNO terminal will be used for NC lock, the NC terminal will beused.
ThisaccesscontrolmachineispoweredbyDC12Vandworkcurrent400mA.IfthelockworkelectricpowerisDC12Vandtheworkcurrent is less than1000mA, the fingerprintmachineandlock are able to be powered by one adapter together, pleaserefertotable1,2.
In the following three cases,we recommend that fingerprintmachineandlockarepoweredseparately.
1)Theworkingvoltageof the lock isDC12V,but thecurrentdifferenceofthefingerprintmachineandthelockdoesntexceed1A.
2)ThelockvoltageisnotDC12V.
3)Thedistancebetween lockand fingerprintmachine is toofar.
iFaceSeriesInstallationGuideV1.0
10
Picture1Powerbyonesupply
Picture2powerbyonesupply
NCLOCK
NOLOCK
DC12V
DC12V
iFaceSeriesInstallationGuideV1.0
11
Picture3Theterminalandlockpoweredbyindependentadapters
Picture4Theterminalandlockpoweredbyindependentadapters
NOLOCK
NCLOCK
LockPower
LockPower
DC12V
DC12V
iFaceSeriesInstallationGuideV1.0
12
2.5Ethernetconnection
TheterminalprovidetwowaysconnectEthernet.1TheterminalconnectwithPCthroughcrosscable
2The terminal connect with PC through network and HUB tocreatealocalnetwork
IP192.168.1.100SubMask255.255.255.0
IP192.168.1.101Mask255.255.255.0
Switch
PC
PCiFace
iFaceSeriesInstallationGuideV1.0
13
iFace
2.6RS232connection
TheterminalconnectwithPCthroughRS232NoteDont upload or download facialmodule throughRS232,becausethelargedatawilleffectthetransferspeed.
PCSerialPort
iFaceSeriesInstallationGuideV1.0
14
PC
2.7RS485connection
TheterminalconnectwithPCthroughRS485NoteDont upload or download facial module through RS485becausethelargedatawilleffectthetransferspeed.
RS485Switch
RS232
RS485
iFaceSeriesInstallationGuideV1.0
15
2.8WiegandOutputConnection
ThedevicehasWiegandoutputfunction,canconnectthemajorityaccess
controllersonthemarket,atthistimeitisusedasareader
Note1Thedistancebetweendeviceandaccesscontrollerorcardreadershouldntbeover90meters(Ifalongerdistanceisneededorthereis
interferenceinusingenvironment,pleaseuseWiegandsignaldelay.).
2)ToensurethestabilityoftheWiegandsignal,thedevicemustsharethe
GNDwithcontrollerorWeigandreader.
3)IfthedistanceofWiegandoutputor485communicationisover90meters,
inordertoreducetheinterferencecausedbythelongdistance,itis
suggestedtousethecablewithshieldandconnecttheshieldcabletothe
SGNDterminal.
iFaceSeriesInstallationGuideV1.0
16
2.9PowerConnection
ThedevicesworkingvoltageisDC12V,withworkingcurrent500mA,standbycurrent50mA.hasprovidedtwowaystoconnectpower,pleaseselectonereferringtotheactual.1Terminalconnection,Makesuretheconnectionasthediagram(Dontconnectthepolesinreverse.).2Slot connection :Insert the plug of DC12V adapter into thepowerslotdirectly.
PowerSlot
DC12V
Terminalconnection Slotconnection
iFaceSeriesInstallationGuideV1.0
17
3.Others
3.1Reset
Due to operation error or other accidence, which leads themachinenottowork,youcanrestartmachinethroughresetkey
takeasmalltoolwhichdiameterisnomorethan2mm
findresetmarkofresontheleftsmallholeonthebottomofdevice,seefollowingfigure
Usethetoolplugintotheholerefertothepictureonright,thenplugout.Themachineisabletorestar
3.2Antidismantlebutton
Antidismantle button is onmiddle of device, whose function is
Reset
iFaceSeriesInstallationGuideV1.0
18
realizedbybackcoverpressingtheantidismantlebutton.Whenthedeviceisbeingdismantled,itwillsendaalarmsignalthroughtheterminal.
3.3Uflashdiskusing
thereisaminiportofUSB,pleaseseefigurecircleontheleft
USBcanbeusedtouploadanddownloaddatabyUdisk,
Antidismantlebutton
iFaceSeriesInstallationGuideV1.0
19
3.4ReserveBattery
WorkprincipleBeforeuse,makesurethereservebatteryis installedproperly.Wheneverusepowersupplyorreservebattery,youneedpresspower key to turn on the terminal. In normal state,When thepower cut down, the reserve batterywill switch into dischargestate to power on the terminal, In power off state, when thepowercutdown,thereservebatterywillnotswitchintodischargestatetopoweron.Ifyouwanttopowerontheterminal,youneedpresspowerkeytoturnontheterminal.
USBPort
iFaceSeriesInstallationGuideV1.0
20
Technicalparameter
Chargetime Lessthan4H Dischargetime
Morethen5.5H
Workingenvironment
050 Relativehumidity
1090
Storingenvironment
Please store the battery when the dischargecapacityisfull.,andtheenvironmentis205
Cycleage Cycletimesofchargeanddischarge300times
Notice
Thereisadangerofbatteryexploding,leak,fever,fire,break,ifyoudontreadthenoticecarefully.
DoNotuseitover50DoNotinversepolarityconnectionDoNotputthebatteryintowaterorletittogetwetDo Not use and store battery near heatgenerating
machine(suchasfireorheater)
Batteryslot
Powerkey
iFaceSeriesInstallationGuideV1.0
21
DoNotthrowbatteriesintofireorhotbatteryDo Not use wire or othermetal short the positive and
negativeterminal.