Ablerex │Three Phase UPS
Three Phase UPS System 100kVA-500kVA
◼ Up to 96% efficiency across a wide load range◼ Near-unity input power factor >0.99◼ Low input harmonic distortion <3%◼ Dual input Mains for independent control of power sources◼ Smart Rotation Redundancy optimized UPS reliability.◼ Intelligent burn-in Technology without load.◼ Large HMI Coloured LCD Touch Screen for advanced control
and monitoring
The BRIC M & BRC Series is a modular UPS ideal for medium to large sized power applications. With its modular structure,the true on-line, double conversion, three-phase UPS system offers a scalable and paralleable architecture for optimalpower designs.
The modular architecture offers a scalable solution by providing the ability to add or removepower modules when the load increases or decreases, ensuring that the UPS system alwaysoperate at optimum efficiency.
Furthering the advantages, the hot-swappable functionality of critical components and powermodules improve the serviceability of the UPS system thereby reducing Mean Time To Repair(MTTR) and ensuring power continuity should a module fails.
In parallel system configuration, the UPS System ensure the highest efficiency also at partial load rate conditions down to very low loadrate conditions - using Smart Rotation Redundancy. Each UPS automatically adjust the number of active power modules (PM) to sharethe load demand equally, putting the remaining power modules in a “sleeping mode”. With this feature, the active PM operate at a highereffective load percentage, thus improving the efficiency and reliability of the overall UPS System.
Overall Active System Capacity: 150kVAOverall Output Supply: 90kVAEffective Total Load Rate: 60%
Achieve Efficiency: 96% Load Demand: 90kVA
UPS 11 PM Active3 PMs SleepingOutput Supply: 30kVAEffective Load rate 60%
Efficiency: 96%
UPS 31 PM Active3 PMs SleepingOutput Supply: 30kVAEffective Load rate 60%
Efficiency: 96%
UPS 21 PM Active3 PMs SleepingOutput Supply: 30kVAEffective Load rate 60%
Efficiency: 96%
The flexibility of the power modules allows parallel expansion to achieve redundancy and to increase the total system capacity. Up to three UPS system can be paralleled without additional hardware.
88.0%
89.0%
90.0%
91.0%
92.0%
93.0%
94.0%
95.0%
96.0%
97.0%
11% 22% 33% 39% 50% 60% 70% 80% 90% 100%
Efficiency
Up to 96%
Load rate
The BRT series is an advanced 3 Phase tower UPS ideal for small and medium data centers. Seamlessly integrated into today's data center design, this design is easily and efficently serviceable, offers a scalable and paralleable architecture as demand grows.
Built-in Maintenance and Static Bypass switch prevents interruption by allowing load transfer to utility during overloads.
Parallel up to 1500kVA to increase the system’s total capacity and providing fail-safe redundancy, thus enhancing its fault managementcapability by preventing a single point of failure.
Featuring Smart Rotation Redundancy, each UPS automatically adjust the number of active subsystem to share the load demand equally, putting the remaining subsystems in a “sleeping mode”. This feature allows the active subsystems to maximise uptime and availability of the overall UPS System.
Soldering surface
Heat sinksComponents here
In order to optimize the performance of the power modules, themodules has an unique air flow design with directed airflow channel.Fans are specifically positioned to direct cool air over the componentsand heat sinks to increase heat dissipation. It prevent dust andmoisture from accumulating at the soldering points that could result inshort circuit.
The UPS is fully equipped with user-friendly monitoring and controls in various languages. A large coloured LCD touch screen provides direct controls and parameters displays on a single page view.
Equip with market largest Smart HMI, the 10.4inch Colored LCD Touch Screen provides real time information, enables direct control andaccess to all parameters and waveforms for management of the UPS System.
Multiples high power density subsystems comprise of advanced IGBT electronics with speed controlled cooling fans are integrated intothe compact UPS tower design. The design features of multiple subsystems is to facilitate ease of maintenance and repair, and spacesaving with a small footprint of 0.5m2 at 100kVA.
Taurus BRT 150kVA~200kVA
Taurus BRT 400kVA~500kVA
Taurus BRT 120kVA
Width 600mm
Width 650mm
Width 1300mm
Height1400mm
Depth980mm Depth
960mm
Height1600mm
Height2000mm
Depth1100mm
Flexible Modular Design
Air Flow Design
Parallel Architecture
Smart Rotation Redundancy
Smart Human Machine Interface
Smart Rotation Redundancy
Smart Human Machine Interface
Parallel Architecture
Built-in Maintenace and Static Bypass
IGBT Technology
Bric M & BRC Series Modular Online UPS (20kVA~500kVA) BRT33 Tower Online UPS (100kVA~500kVA)
50kVA
Sleeping mode
Active mode
Active mode
Sleeping mode
Sleeping mode
Sleeping mode
Active mode
200kVA 200kVA200kVA
50kVA
50kVA
Ablerex │Three Phase UPS
Power Module Model BRIC M-20P BRIC M-30P BRIC M-40P BRIC M-50P
Power Rating 20KVA/18kW 30KVA/27kW 40KVA/40kW 50KVA/45kW
Voltage, Phase
Voltage Range
Frequency
Power Factor
THDi
Voltage, Phase
Voltage Range
Frequency
Frequency Tolerance
Voltage, Phase
Voltage Tolerance
Power Factor 1.0 0.9
Frequency
Frequency Tolerance
Crest Factor
THDu
Protection Overload Capacity
DC Voltage
Number of batteries
Charging Power
VFI Mode
ECO Mode
Display
Built-in Communication
Optional Communication
Optional Add-ons
Power Module Dimension (mm) 440 (W) 590 (D) 134 (H) 440 (W) x 590 (D) x134 (H)
Power Module Weight 22kg 34kg 44kg 45kg
Protection Index
Noise (at 1 meter)
Operating Temperature
Operating Humidity
Safety and EMC
Markings
Cabinet Model Maximum Capacity Max. No. of Power Modules Cabinet Dimension (mm) Cabinet Weight Parallel Operations
BRIC M-60-20P 60kVA Up to 3 nos. x Bric M-20P 600 (W) 900 (D) 1100 (H) 105kg Up to 2 Cabinets
BRIC M-120-20P 120kVA Up to 6 nos. x Bric M-20P 600 (W) x 900 (D) x 1600 (H) 145kg Up to 2 Cabinets
BRIC M-200-20P 200kVA Up to 10 nos. x Bric M-20P 600 (W) x 900 (D) x 2000 (H) 179kg Up to 2 Cabinets
BRIC M-180-30P 180kVA Up to 6 nos. x Bric M-30P 600 (W) 1100 (D) 1600 (H) 165kg Up to 3 Cabinets
BRIC M-300-30P 300kVA Up to 10 nos. x Bric M-30P 600 (W) 1100 (D) 2000 (H) 220kg Up to 3 Cabinets
BRIC M-600-30P 600kVA Up to 20 nos. x Bric M-30P 2000 (W) 1100 (D) 2000 (H) 660kg No
BRIC M-80-40P 80kVA Up to 2 nos. x Bric M-40P 600 (W) 980 (D) 1150 (H) 115kg Up to 3 Cabinets
BRIC M-160-40P 160kVA Up to 4 nos. x Bric M-40P 650(W) 960 (D) 1600 (H) 165kg Up to 3 Cabinets
BRIC M-240-40P 240kVA Up to 6 nos. x Bric M-40P 650 (W) 970 (D) 2000 (H) 215kg Up to 3 Cabinets
BRIC M-400-40P 400kVA Up to 10 nos. x Bric M-40P 1300 (W) 1100 (D) 2000 (H) 900kg Up to 3 Cabinets
BRIC M-100-50P 100kVA Up to 2 nos. x Bric M-50P 600 (W) 980 (D) 1150 (H) 115kg Up to 3 Cabinets
BRIC M-200-50P 200kVA Up to 4 nos. x Bric M-50P 650 (W) 960 (D) 1600 (H) 165kg Up to 3 Cabinets
BRIC M-300-50P 300kVA Up to 6 nos. x Bric M-50P 650 (W) 970 (D) 2000 (H) 215kg Up to 3 Cabinets
BRIC M-500-50P 500kVA Up to 10 nos. x Bric M-50P 1300 (W) 1100 (D) 2000 (H) 900kg Up to 3 Cabinets
20% of UPS Capacity
Battery
>99%
>95%
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute, >150% for 200ms
36~44pcs configurable
±240Vdc (with +/N/- connections)
10.4" LCD Coloured Touch Screen
RS232, RS485, USB, Dry Contact
Parallel kit, Battery cold start kit (standard for 250kVA and above)
>96%
Standards and
Certifications
IEC/EN 62040-1 (Safety) and IEC/EN 62040-2 (EMC)
TUV-SUD
0~40C
Physical
510 (W) 700 (D) 178 (H)
IP20
72dB at 100% load; 62dB at 45% load
Environment0~95% (without condensation)
Input
Interface
System
380V / 400V / 415V, 3 Phase + N + G
304V ~478V line to line at full load
50Hz / 60Hz
≥0.99
<3%
380V / 400/V / 415V, 3 Phase + N
50/60Hz
±0.01% (free running)
SNMP Card, AS400
0.9
Ouput
Bypass
380/400/415V, 3 Phase + N + G
-20% to 15%
50/60Hz
±3Hz
3:1
<1% for linear load; <5.5% for non-linear load
±1.5%
BRIC M Series On-Line Modular UPS20KVA ~ 500KVA
Specification
◼ Bric M-180
◼ Bric M-300
◼ Bric M-400◼ Bric M-500
◆ Hot-Swappable Power Modules to reduce Mean Time to Repair (MTTR)
◆ High Power Density
◆ High Efficiency >96% in On-line mode
◆ High Input Power Factor >0.99
◆ Low Input Harmonic, THDi% <3%
◆ High Scalability supporting N+X redundancy
◆ Smart Sleep Mode for Energy Saving
◆ Advanced Operation Interface -- 10.4" Colored LCD Touch Screen
Ablerex │Three Phase UPS
Power Module Model
Power Rating
Voltage, Phase
Voltage Range
Frequency
Power Factor
THDi
Voltage, Phase
Voltage Range
Frequency
Frequency Tolerance
Voltage, Phase
Voltage Range
Power Factor
Frequency
Frequency Tolerance
Crest Factor
THDu
Protection Overload Capacity
DC Voltage
Number of batteries
Charging Power
VFI Mode
Backup Mode
ECO Mode
Display
Built-in Communication
Optional Communication
Parallel
Power Module Dimension (mm)
Power Module Weight
Protection Index
Noise (at 1 meter)
Operating Temperature
Operating Humidity
Safety and EMC
Markings
Cabinet Model Maximum Capacity Max. No. of Power Modules Cabinet Dimension (mm) Cabinet Weight Parallel Operations
BRC-150 150kVA Up to 6 nos. x BRC-25C 485 (W) x 900 (D) x 1072 (H) 140kg Up to 3 Cabinets
BRC-200 200kVA Up to 8 nos. x BRC-25C 482 (W) x 916 (D) x 1550 (H) 160kg Up to 3 Cabinets
Bypass
Physical
Up to 3 units
436 (W) 677 (D) 85 (H)
65dB
18kg
IP20
TUV-SUD
Standards and
Certifications
0~40C
50/60Hz
±0.1% (free running)
3:1
<1% for linear load; <6% for non-linear load
32~44pcs configurable
BRC-25C
25kVA/25kW
±240Vdc (with +/N/- connections)
Input
380V / 400V / 415V, 3 Phase + N + G
304V ~478V line to line at full load
40~70Hz
≥0.99
<3%
380/400/415V 3 Phase + N + G
Settable, -40% ~ +25%
50/60Hz
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute, >150% for 200ms
±1Hz, ±3Hz, ±5Hz (Setectable)
Battery
Output
±1% (Static Load)
380V / 400V / 415V, 3 Phase + N + G
IEC/EN 62040-1 (Safety) and IEC/EN 62040-2 (EMC)
1.0
>96%
10.4" Colorful LCD Touch Screen
RS232, RS485, Dry Contact
SNMP
>95%
>99%
Interface
System
Environment0~95% (without condensation)
20% of UPS Capacity
BRC Series On-Line Modular UPS25KVA ~ 200KVA
Specification
◼ BRC-150
◼ BRC-200
◆ Three-Phase Modular System designed for Rack Integration
◆ Hot-Swappable Power Modules to reduce Mean Time to Repair (MTTR)
◆ High Power Density
◆ High Efficiency >96% in On-line mode
◆ Low Input Harmonic, THDi% <3%
◆ High Scalability supporting N+X redundancy
◆ Advanced Operation Interface -- 10.4" Colored LCD Touch Screen
Model BRT33 100P BRT33 120P BRT33 150P BRT33 200P BRT33 250P BRT33 300P BRT33 400P BRT33 500P
Power Rating 100kVA/90kW 120kVA/108kW 150kVA/135kW 200kVA/180kW 250kVA/225kW 300kVA/270kW 400kVA/360kW 500kVA/450kW
Voltage, Phase
Voltage Range
Frequency
Power Factor
THDi
Voltage, Phase
Voltage Range 20% to 15%
Frequency
Frequency Tolerance
Voltage, Phase
Voltage Tolerance
Power Factor
Frequency
Frequency Tolerance
Crest Factor
THDu
Protection Overload
Voltage
Charging Power
VFI Mode >96% >95.5%
Backup Mode >96% >95%
ECO Mode
Display
Built-in Communication
Optional Communication
Optional Add-Ons
Parallel
Weight 210kg 266kg 305kg 350kg 445kg 490kg 810kg 900kg
Operating Temperature
Operating Humidity
Protection Grade
Noise (at 1 meter)
Safety and EMC
Markings
Input
InterfaceStandard: RS232, RS485, USB, Dry Contact
Battery
3:1
±0.01% (free running)
<3%
380/400/415V 3 Phase + N + G
±1.5%
0.9
50/60Hz
SNMP, AS400
10.4" Colorful LCD Touch Screen
<1% for linear load; <5.5% for non-linear load
110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute, >150% for 200ms
±240Vdc (with +/N/- connections)
CE
Environment
0~40C
IEC/EN 62040-1 (Safety) and IEC/EN 62040-2 (EMC)Standards and
Certifications
Ablerex │Three Phase UPS
400V 3 Phase + N + G
+20%, -24%
45~70Hz
≥0.99
20% of UPS Capacity
>96%
System >96%
>99%
Parallel kit, Battery cold start (standard ofr 250kVA above), Lightning protection components, Dust filter, LBS
0~95% (without condensation)
IP20
<68dB at 100% load; 65dB at 45% load <72dB at 100% load; 69% at 45% load
Up to 1500kVA
650 (W) 960 (D) 2000 (H) 1300 (W) 1100 (D) 2000 (H)
Bypass
380/400/415V 3 Phase + G + N
50/60Hz
±1Hz, ±3Hz, ±5Hz (Setectable)
Ouput
PhysicalDimension (mm)
600 (W)
980 (D)
1150 (H)
600 (W)
980 (D)
1400 (H)
650 (W) 960 (D) 1600 (H)
BRT33 Series On-Line Tower UPS100KVA ~ 500KVA
Specification
◼ BRT33 150P◼ BRT33 200P
◼ BRT33 400P◼ BRT33 500P
◆ Front Access for operation and maintenace reduces Mean Time to Repair
(MTTR)
◆ High Power Density, Small Footprint
◆ High Efficiency >96% in On-line mode
◆ High Input Power Factor >0.99
◆ Low Input Harmonic, THDi% <3%
◆ Built in Backfeed Protection and Maintenance Switch
◆ Advanced Operation Interface -- 10.4" Colored LCD Touch Screen
Mars II SeriesConvertible Redundancy On-Line UPSMSII RT 4500VA~20000VA
■ Simple Parallel Installation
■ Full-time Digital Signal Processor Control
■ Frequency Converter Operation Mode
■ Smart ECO Mode
■ LCD Mimic Panel
■ Power Range and Runtime Scalability
■ Maintenance Bypass Switch Embedded
■ Optional Galvanic Isolation Transformer
■ Optional Hot Swappable Battery
Ablerex, Experts in Power Conversion|Single Phase UPS
Display
Alarms
Code Bat. Type Max. Quantities Dimensions (HxWxD, mm/inch)
Physical
Protection
Environmental
Interface
Standards and Certifications
Model MSII 20000 RTMSII 15000RTMSII4500RT MSII6000RT MSII6000C MSII8000RT / 8000PRT
MSII10000RT /10000PRT
MSII10000C
Voltage
Frequency
Power Factor
Voltage
Capacity
Frequency (Battery Mode)
Operating Temperature
Noise Level
Altitude
Humidity
Interface Type
Communication Slots
Compatible Platforms
Safety Standard
EMC Standard
Marks
Input
Output
0~40°C/ 32~104°F
1000m / 3280ft without Derating
20%~95%RH (Without condensation)
2nd RS232, USB, RS485, Relay Contact, SNMP/WEB Card
Microsoft Windows series, Linux, Mac, etc.
160~280Vac (1Φ) / 277 – 485Vac (3Φ)**160~280Vac 277~485Vac(3Φ)**
220/230/240Vac Selectable
440x220x720/ 17.3x8.6x28.2
36/79.2
<60dBA
Standard RS232 & EPO
EN62040-1-1
EN62040-2
CE
Battery
* Specifications subject to change without notice.** Based on load percentage.*** Standard configuration - back-up time at 70% of the load.
****Depending on the model and voltage, please contact Ablerex for more information.*****The same technical specification may be sold in different countries under different
model names, please consult Ablerex for more information.
UPS mode
Battery Bank SpecificationsMSII RT 4500 / 6000VA MSII RT 8000 / 10000VA MSII RT 4500 / 6000VA (ODIN) MSII RT 8000 / 10000VA (ODIN) MSII RT 15000 / 20000VA
C20J3U07C20N3U09C20J4U07C20N4U09C20V3U09
7AH9AH7AH9AH9AH
2020202020
132x440x680 / 5.2x17.3x26.8132x440x680 / 5.2x17.3x26.8176x440x550 / 6.9x17.3x21.7176x440x550 / 6.9x17.3x21.7132x440x680 / 5.2x17.3x26.8
1Φ, Line + Neutral + Ground3Φ, R, S, T + Neutral + Ground1Φ, Line + Neutral + Ground 3Φ, R, S, T + Neutral + Ground
Up to 0.95 at Linear LoadUp to 0.99(1Φ) / 0.95(3Φ) at Linear Load
200/208/220/230/240Vac Selectable(208/120Vac optional)
<50dBA
Standard RS232
EN62040-1-1, UL1778
EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A
CE, cUL, UL****
N.A. N.A. 4 hours to 90%
12V/7AH 12V/5AH
24/52.9 17.5/38.5 (ODIN) 52/114.6 45/99.2(8K/10KRT)
50/110.2 (8K/10KRTP) 96/211.2
440x88x680/17.3x3.5x26.8 440x132x550/
17.3x5.2x21.6 (ODIN)
440x176x680/17.3x6.9x26.8
440x264x680/17.3x10.3x26.8
440x132x680/ 17.3x5.2x26.8
12V/9AH
N.A. N.A. N.A.N.A. 4 hours to 90%
4050W 5400W 7200W 9000W 13500W 18000W
Inverter Supply: 105%~150% for 160 sec. ~ 2 cycles before switching bypass.
Bypass Supply: 105%~200% for 500 sec. ~8 cycles before stopping supply load.
www.ablerex.com.tw
■ MSII 10000VA RT■ Battery Bank
Dimensions (WxHxD, mm/inch)ODIN:Dimensions (Short Version)
Weight (kg/libs)ODIN:Weight (Short version)
45 ~ 65 Hz
±1Hz or ±3Hz (Selectable)
20pcs (without Battery in RT power module type)
240Vdc
Phase
Current Crest Ratio
Harmonic Distortion
Output Waveform
Transfer Time (AC to DC)
Efficiency
DC Start
Number of batteries
Type
Capacity
Rated Battery Voltage
Recharge Time
Status On LED + LCD
Readings on LCD
Self-Diagnostics
Audible and Visual
Overload Capacity
Short Circuit
EPO
Over Temperature
3:1
< 3% at Linear Load
Pure Sine Wave
0ms
Yes
Sealed Lead Acid Maintenance Free
105%~150% for 600sec. ~ 1 sec.before switching bypass.
105%~150% for 600sec. ~ 1 sec.before stopping supply load.
90% 91%
Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, and Transferring with interruption & UPS Fault.
Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature.
Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking
Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions
Output Breaker/Electronic Circuit
Output shuts down immediately
AC Mode: Switch to Bypass / Backup Mode: Switch off the UPS
Mars III SeriesHigh Performance Redundancy On-Line UPSMSIII Tower (MSII PLUS) 4500VA~10000VAMSIII RT (MSII PLUS RT) 4500VA~10000VA
■ Rack/Tower Convertible Design
■ Power Factor 1.0
■ Patent Backup Runtime Estimation
■ Flexible Battery Configuration
■ Easy Parallel Installation
■ Frequency Converter Operation Mode
■ Smart ECO Mode
■ Generator Compatible Mode
■ Full-time Digital Signal Processor (DSP) Control
■ LCD Mimic Panel
■ Power Range and Runtime Scalability
■ Optional Galvanic Isolation Transformer Module / MTBS Box
Ablerex, Experts in Power Conversion|Single Phase UPS
* Specifications subject to change without notice, and the final explanation rights are reserved by Ablerex.** Depending on load percentage : 176-280 VAC, without derating ; 160-176 VAC, derating to 75% Load ; 110-160 VAC , derating to 50% Load*** Max. depending on number of battery. PF:1.0-10K(20S),6K(20S/18S/16S) ; PF:0.9/0.8-10K(18S),6K(14S) ; PF:0.7-10K(16S),6K(12S)**** Depending on the model and voltage, more information please contact with Ablerex.
www.ablerex.com.tw
■ MSIII10000RT■ MSIII10000RT
■ MSIII6000RT 4U ■ MSIII 4.5/6KVA (with TR) ■ MSIII 8/10KVA (with TR)
Battery Bank SpecificationsUPS model Code Max Battery number / String Max Battery Quantities Dimensions(HxWxD,mm)MSIII 4.5K~10K Tower BT602403 20 60 700x288x657 / 27.6x11.3x25.9MSIII 4.5K~6K RT BC202406 20 20 88x440x483.5 / 3.5x11.3x26.9MSIII 8K~10K RT BC202403 20 20 132x440x685 / 5.2x11.3x27
≦60dBA @ 1 Meter≦60dBA @ 1 Meter
1Φ, Line + Neutral + Ground
40~60Hz 50~70Hz ≦5%
Up to 0.99 @Linear Load
≦2% @ 100% Linear load≦3% @ 100% non-linear load(PF=0.9) ≦7% @ 100% non-linear load(PF=0.7)
110-280VAC
MODEL MSIII 4.5K / MSIII-RT 4.5K MSIII 6K / MSIII-RT 6K MSIII 8K / MSIII-RT 8K MSIII 10K / MSIII-RT 10K
Input Output 50HzOutput 60Hz
Output
4500VA/4500W 6000VA/6000W 8000VA/8000W 10000VA/10000Wwithout Transformer 200/208/220/230/240Vac, settable with Transformer 120/208 or 110/220 or 115/230 or 120/240
1
without Transformer ±1%with Transformer ±3%
(Synchronized Range) ±1Hz or ±3Hz (Selectable)3:1
Pure Sine Wave
Efficiency
without Transformer 93% 94%with Transformer 90% 91%without Transformer 98%with Transformer 94% 95%
Battery
12/14/16/18/20 16/18/20VRLA, Sealed Maintenance Free Lead Acid
4hours12/14/16 Model 2-step(CC-CV), 1.9A(max.) N/A16/18/20 Model 2-step(CC-CV), 1.7A(max.)
Display
Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, and Transferring with interruption & UPS Fault
Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature, Backup time estimationUpon Power-on, Manual control by panel & communication, self routine check
Alarm Line Failure / Battery Low / Transfer to Bypass / System Fault
Protection Overload, Over temperature, Short circuit, ABDM, overcharge
Function
Normal/ ECO/ CVCFYes
up to 4 units3+1
Physical
Dimensions (WxHxD, mm/inch) 240x509x700 / 9.5x27.6x20 288x509x700 / 11.3x20x27.6
Net Weight (kgs/lbs) 76/167 91/200Dimensions (WxHxD, mm/inch) 240x657x700 / 9.5x25.9x20 288x657x700 / 11.3x25.9x27.6
Net Weight (kgs/lbs) 119 / 262.3 133 / 293.2
Dimensions (WxHxD, mm/inch) 440x88x685 / 17.3x3.5x26.0 440x132x685 / 17.3x5.2x26.0
Net Weight (kgs/lbs) 18.5 / 40.8 21.5/47.4
Dimensions (WxHxD, mm/inch) 440x176x685 / 17.3x6.9x26.0 N/A
Net Weight (kgs/lbs) 60/132.3 (5Ahx20) N/ADimensions (WxHxD, mm/inch) 440x88x660 / 17.3x3.5x26.0 440x132x660 / 17.3x5.2x26.0
Net Weight (kgs/lbs) 42 / 92.6 58 / 127.9
Environmental
0~40°C/ 32~104°F20%~95%RH (Without condensing)
1000m/3280ft without Derating
InterfaceUSB, EPO/ROO
2nd RS232, USB, RS485, Dry Contact Relay, SNMP/WEB Cardmicrosoft Windows series, Linux, Mac, etc.
Standards and Certifications****
EN62040-1, UL1778EN62040-2, FCC part 15 Class A, EN61000-2-2, EN61000-3-2/3,
PhaseVoltage Range**
Frequency Range
Input Current DistortionInput Power FactorCapacity
Voltage
Output Power Factor***
Output Voltage Distortion
Output Voltage RegulationFrequency RangeCrest FactorOutput Waveform
Line Mode
High Efficiency ModeNumber of BatteryBattery TypeRecharge Time (to 90%)
Charger
Status On LED + LCD
Readings On LCD
Self-Diagnostics
Audible or Visual
Full Protection
Multi-ModeDC startParallel capacityParallel redundancy
Tower Model(with Batt)
Tower Model(with Transformer & Batt)
RT Model
RT Model(with Battery)
RT TransformerModule
Operation TemperatureOperation HumidityAltitudeNoise LevelStandardOptionCompatible PlatformsSafetyEMCMarks CE/TUV, cULus