Serving the Medical Community with Vascular Technology Since 1973
Hokanson Product Catalog
Since 1973, D. E. Hokanson, Inc. has provided reliable noninvasive vascular diagnostic instruments of the highest quality to the medical community. We manufacture our instruments with a commitment to excellence in research, materials and workmanship. You, our customers, are a key factor in our research and development process. We invite you to contact us with feedback about your Hokanson products. Following this tradition we continue to update and add to our product line.
This catalog gives a general description of each of our products. For more specific information or for the name of your local Hokanson representative, please contact Hokanson directly or visit our website at www.hokanson.cc. We look forward to working with you in providing convenient, effective health care throughout the world.
Kyra Hokanson Gray, President
Quality at an Affordable PriceExceptional value
Ourgoalwithevery instrument is tomake iteasy touse,accurateandreliable–allatareasonableprice.YourinvestmentinHokansonwillserveyouwellandkeepitsvalue.
Ease of operation Selfexplanatorybuttonscontrolthemostimportantfunctionsofeachofourinstruments.Wedesigneveryinstrumenttoensurethatthecontrolsarelogical,visibleandeasytohandle.
Outstanding quality Our quality control program of mechanical and thermal shock testing for all Hokansoninstrumentshelpstopreventmanyinstrumentfailuresandallowsustoconfidentlyofferafullfiveyearwarranty–thelongestintheindustry.
Accurate resultsHokansoninstrumentsutilize thehighestqualitycomponents.Eachinstrument is thoroughlytestedforfunctionandaccuracy.
A history of reliabilityHealthcareprofessionalshavedependedonHokansoninstrumentssince1973.Todayourinstrumentsareatworkinover35nations.
Hokanson is ISO 13485 certified.All our products carry the European CE mark.
D.E.Hokanson,Inc.12840NE21stPlace
Bellevue,WA98005USATelephone:1800.999.8251or
425.882.1689Fax:425.881.1636
Website:www.hokanson.ccE-mail:[email protected]
About Hokanson
1
Our Catalog
Tests and Applications Doppler PPG Pneumo Strain Specialty Gauge
Upper&LowerExtremityArterial&VenousDoppler √ Vascular
Upper&LowerExtremitySpectralDoppler √ Vascular
Upper&LowerExtremitySegmentalBloodPressure √ √ √ Vascular
BloodPressureinAllDigits √ √ Vascular
BloodPressureinAllLimbs √ √ √ Vascular
DigitandLimbPulseVolumeRecording √ Vascular
CarotidDoppler √ Vascular
PenilePressureandPlethysmography √ √ √ √ Vascular
ThoracicOutletSyndrome √ Vascular
MaximumVenousOutflow √ √ Vascular
VenousReflux √ √ √ Vascular
VenousInsufficiencywithDuplexScanner Phlebology
VenousRefluxwithDuplexScanner Phlebology
AnkleBrachialIndex √ √ √ PrimaryCare
ToeBrachialIndex √ √ PrimaryCare
ToePressures √ PrimaryCare
PostExercisePressureswithAutomaticABICalculation √ √ PrimaryCare
Pulses √ Hospital
SystolicBP √ Hospital
PostRevascularizationPulseCheck √ Hospital
continues next page
How to use this catalog
Hokansonbecameacompanytomeettheneedsofthevascularcommunityofresearchersandcliniciansandnowhasembracedthevenousandprimarycarepractitioners.Ourcatalogtailorstheinstrumentstoyourprofessionalspecialty:Vascular,Phlebology,PrimaryCare/HospitalorResearch.Foreaseofuse,wehavecolorcodedourproductstoyourspecialtyandreferencethemusing
tabsonrighthandpages.Attheendofthecatalogisadisplayofallofourcuffsbytypeandsomeaccessories.
Tests and applicationsIfyouaremorecomfortablethinkingintermsofthetestsyouperform,wehaveprovidedamatrixbelowthatlinkseachtesttotheappropri-ateinstrument,alsogroupedbyspecialty.Forsamplereports,researchpapersandbrochuresonalloftheseinstruments,pleasevisitourwebsiteatwww.hokanson.cc.
HokansonprovidesyouwithachoiceofDopplersaswellasphoto,pneumoandstraingaugeplethysmographyinstruments.Manytestscanbeperformedusingseveralmodeswithsomemodesworkingbetterthanothersdependingonthesitetobetested.AdditionallyHokansonhascuffinflatorsincludingsphygmomanometers,automatedandrapidinflation/deflationtomeetyourvarioustestingneeds.Wearethemajorvascularcuffmanufacturerwithdigitandsegmentalcuffsinawidevarietyofsizesandtypes.
Hokansoninstruments,cuffs,inflatorsandaccessoriesareallmadeintheUSA.
Key to matrix Vascular:Includesvascularlabs,vascularsurgeons,cardiovascularsurgeonsandcardiologists.
Phlebology:Includesveinclinics,veinspecialistsandvascularsurgeons.
Primary Care:Includesinternists,familypractice,homehealthorclinicsandhospitals.
Research:Includesresearchersindiabetes,endovascularfunctionandarterialinflowstudies.
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 2
ArterialInflowVenousOcclusionPlethysmography/EndothelialFunction √ √ Research
VenousOutflowandVenousCapacitance √ √ Research
ColdSensitivity √ √ Research
ArterialPressures&QualitativeWaveformAnalysis √ √ Research
AutomaticReactiveHyperemia √ Research
Tests and Applications Doppler PPG Pneumo Strain Specialty Gauge
Our Tests & Applications
continued from previous page
Inthechartbelow,alltestswhereaDopplercouldbeusedtoperformthetestarelistedfirst,followedbyallteststhatcanusephotoplethysmography,thenallthatcanusepneumoplethysmographyand,last,straingaugeplethysmography.Instrumentsarelistedfromsimplesttomostcomplexintheinstrumentfields.
Upper&LowerExtremityArterial&VenousDoppler
Upper&LowerExtremitySpectralDoppler
AnkleBrachialIndex
ToeBrachialIndex
PostExercisePressureswithAutomaticABICalculation
Upper&LowerExtremitySegmentalBloodPressure
BloodPressureinAllLimbs
CarotidDoppler
PenilePressureandPlethysmographyVenousReflux
Pulses
SystolicBP
PostRevascularizationPulseCheck
MD6System–MD35–CVS4
CVS4
PortableABIKit–MD6System–MD35–CVS4
TBIPackage–MD6System–MD35–CVS4
MD35–CVS4
MD6System–MD35–CVS4
PortableABIKit–MD6System–MD35–CVS4
MD6Doppler–MD35Doppler
MD35–CVS4–EC6
MD35–CVS4–EC6
MD6Doppler–UW7Doppler
PortableABIKit–MD6Doppler–UW7Doppler
MD6Doppler–UW7Doppler
√
√
√
√
√
√
√
√
√
√
√
√
√
Vascular
Vascular
PrimaryCare
PrimaryCare
PrimaryCare
Vascular
Vascular
Vascular
Vascular
Vascular
Hospital
Hospital
Hospital
√
√
√
√
√
√
√
√
√
√
√ √
√
continues next page
Tests and Applications Instrument Doppler PPG Pneumo Strain Specialty Gauge
3
Our Tests & Applications
ThoracicOutletSyndrome
BloodPressureinAllDigits
ToePressures
ArterialInflowVenousOcclusionPlethysmographyVenousOutflowandVenousCapacitanceColdSensitivity
ArterialPressuresandQualitativeWaveformAnalysis
MaximumVenousOutflow
DigitandLimbPulseVolumeRecording
AutomaticReactiveHyperemia
MD6–MD35–CVS4ToePressureKit–MD6System–MD35–CVS4ToePressureKit–MD6System–MD35–CVS4EC6–AI6
EC6–AI6MD6–MD35–CVS4EC6–AI6MD35–CVS4–EC6
MD6System–MD35–CVS4
EC6–AI6
Vascular
Vascular
Vascular
PrimaryCare
Research
ResearchResearch
Research
Vascular
Vascular
Research
√
√
√
√
√√
√
√
√
√
√
√√
√
√
√
Tests and Applications Instrument Doppler PPG Pneumo Strain Specialty Gauge
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 4
Index
Thefollowingindexliststhelocationofeveryoccurrenceforeachcategory,instrumentoraccessoryinthecatalog.
Vascular
CVS4.................................................................................................... 6
DICOMExtension................................................................................... 7
MD35(MobileVascular)......................................................................... 8
MD35ProcordSystemOption.................................................................. 9
MD35ProcordSystemBasicOption......................................................... 9
SegmentalPressurePackageOption......................................................... 9
NIVP3Software................................................................................... 10
TD312CuffInflator................................................................... 10,16,22
StraightSegmentalCuffs.................................................................. 11,29
ContouredCuffs....................................................................... 11,19,29
DurableDigitCuffs......................................................................... 12,31
ThermalChartPaper................................................................. 12,16,32
RD2RapidCuffDeflator.................................................................. 13,28
MV10SegmentalCuffSelector......................................................... 13,28
MD6System........................................................................................ 14
MD6BidirectionalDoppler.................................................................... 14
MD6RPPhotoPlethysmograph................................................................ 15
MD6PNPneumoPlethysmograph........................................................... 15
MD6VRChartRecorder......................................................................... 15
MD6Doppler................................................................................. 17,22
MD6PocketDopplerwithDetachableTransducer............................... 17,23
Phlebology/Venous
RapidCuffInflationSystem.................................................................... 18
E20TimersandFootSwitch............................................................. 18,19
RapidVersionSegmentalCuffs.........................................................19,30
ContouredCuffs....................................................................... 11,19,29
Primary Care or Hospital
PortableABIKit.................................................................................... 20
TBIPackage......................................................................................... 21
ToePressureKit.................................................................................... 21
TD312CuffInflator................................................................... 10,16,22
MD6Doppler................................................................................. 17,22
MD6PocketDopplerwithDetachableTransducer............................... 17,23
UW7Doppler................................................................................ 23,34
Where to find Page
5
Index
Research Studies
AI6AutomatedStrainGaugePlethysmographySystem............................. 24
EC6StrainGaugeandPhotoPlethsymograph.......................................... 25
E20/AG101RapidCuffInflationSystem................................................. 25
E20CycleTimer................................................................................... 25
StrainGauges...................................................................................... 26
PositioningAids.............................................................................. 26,33
DS400AneroidSphygmomanometer...................................................... 27
NIVP3ArterialInflowSoftware............................................................... 27
Accessories and Cuffs
MV10SegmentalCuffSelector......................................................... 13,28
RD2RapidCuffDeflator.................................................................. 13,28
StraightSegmentalCuffs.................................................................. 11,29
ContouredCuffs....................................................................... 11,19,29
RapidVersionStraightSegmentalCuffs............................................. 19,30
ReplacementBladdersforCuffs.............................................................. 30
DurableLatexFreeDigitCuffs.......................................................... 12,31
DurableLatexDigitCuffs................................................................. 12,31
DisposableDigitCuffs........................................................................... 31
VascularCuffSets................................................................................. 32
ThermalChartPaper................................................................. 12,16,32
UltrasonicCouplingGel........................................................................ 33
PositioningAids.............................................................................. 26,33
Doppler..................................................................... 14,17,22,23,34
Plethysmographs................................................................. 15,25,35
Hokanson Policies........................................................................... 36
Where to find Page
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 6
CVS4 Everything you need
T heCVS4isaCompletePhysiologicalPeripheralVascularautomatedandcomputerizedsystemforthevascularcom-munity.Everythingyouneedtoperformphysiologicalstudies
usingDoppler,photoplethysmographyorpneumoplethysmogra-phycomeswiththissystem.Included with your purchase is one day of on-site set up and instrument training.
The CVS4 for noninvasive peripheral vascular testing provides:
• Exceptionalvalue
•Reliable,affordabletechnology
•Easeofoperation
•Outstandingquality
•Accurateresults
CVS4 components:
•ContinuousWaveDopplerspectraandzero-crossingDopplerwithbifocallensfordeep&superficialvesselswithonetransducer.
•AutomaticcuffinflatorandsoftwareremotecontrolTD312
•CuffselectorMV10
•CompletesetofcuffsforperformingsegmentalpressuresandPVR’s
•Customcart
• Flatpanelmonitor,minidesktopcomputer(Windows®)andHPDeskjetcolorprinter
CVS4 computerized reports:
•Storespatientinformation,waveformsandpressures
•Printedcolorreportsforalltests,withafeaturethatprintsonlythetestsyouwant
• Includesmultiplevisitgraphsforfollowuppatients
• TheDICOMExtensionisavailableasanaddontointerfacewithyourPACSsystem
SpectralanalysisisincludedwiththeCVS4;spectralDopplersoundsaresavedsothatyoucanreviewbothwaveformsaswellasthesounds,anexcellentDopplertrainingtool.Repre-sentativenormalwaveformsarepresentedforbothviewingandlisteningcomparison.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
7
Vascula
r
The DICOM Extension
TheDICOMExtensionsharesdatawithaPACSsystemandcreatesonerecordviewableonallDICOMworkstations;additionallythein-formationviewedonthescreencanbeprinted.Thephysiciancanseebothphysiologicalandduplexinformationforthesamepatientonthesameworkstation.TheNIVP3dataisavailableforviewingincludingplaybackofSpectralDopplerrecordingswithsound,ifDICOMworkstationissoundenabled.ThisapplicationfacilitatesthesharingofthephysiologicalperipheralvasculardataincludingwaveformswithanothersystemorapplicationthatisalsoDICOMcompatible.TheWorkListServerfunctioninNIVP3allowsyoutopopulatethethepatientdemographicsfromthePACSsystem,parsingitanddisplayingitinthecorrectfieldsinNIVP3.Thiseliminatesthehassleofdupli-catedataentrywiththesubsequentpossibilityoferror.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
— The physician can see both physiological and duplex information for the same patient on the same workstation
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 8
MD35 Compact & user friendly
T heMD35istheMobilephysiologicalperipheralvascularsystemthatisidealfortransportingthetesttothepatientviaavanorcar.Youcanbuildoutthesystemtosuityourpracticeincludingcomputerization.Itisflexible,versatileandreliable.ItiscompacttomeetyoursizeconstraintsandcanbecomputerizedusingyourlaptoporPCandprinter.Compactsize,lightweight,andsmall
footprintmakeitidealtofitonashelfinaself-containedlab,inavanorincarryingcasesforgrab-and-gotoanoffice.
IncludedisaCWbidirectionalDopplerwithabifocallensforsuperficialanddeepvessels,eliminatingtheneedfortwoDopplerprobes.TheDopplerprobehascontrolsforvolume,waveforminversionandturningon/offthechartrecorderonthehandle,foryourconve-nience.Aphotoplethysmographytransducerandpneumoplethysmographyarealsoprovided.YoucanperformallofthestandardperipheralvascularphysiologicaltestswiththeMD35.
TheMD35hastencalibratedgainsettings,selectableAC(artery)orDC(venous)couplingandatwospeedchartrecorderforobtainingthebestwaveforms.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
9
Vascula
r
Thefollowingoptionswerecreatedtomeetthetypicalcustomers’needs:
Option: MD35 Procord System
Thissystemincludes:4segmentalcuffsandonecontouredthighcuffandseveraldigitcuffs(forthebasictests)andtheDS400AneroidsphygmomanometerandRD2RapidCuffDeflator.ThisoptiontakestheplaceofthebasicMD35instrumentandincludeseverythinginthebasicMD35.
Option: MD35 Procord BasicThisisthebasicMD35instrumentwithtransducers,andstart-upsupplies.Thissystemisidealforthelabwithexistingcuffs,orsoyoucanchooseyourowncustomcuffset.
Option: Segmental Pressure Package
SupplementaltotheMD35isthesegmentalpressurepackagewithextracuffsforcompletesegmentalpressureandPVRstudiesandtheMV10segmentalcuffselector.
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 10
NIVP3 Software Consistent reporting
Segmental Arterial & Venous Exams Software
T hissoftwarecomeswiththecompleteCVS4system,andisavailablefortheMD35mobileunittocreateconsistenttestswithcomputerizedtestresultsandreporting.NIVP3captures,storesandprintsphysiologicstudiesofupperand
lowerextremityarteriesandveins.ThereisaspectralDoppleroptionavailableforusewiththeMD35ProcordwhichincludestheabilitytorecordandplaybacktheDopplerwaveformsandassociatedaudio.
Youcaneditthedemographicdataandsigns&symptomsquestionstomeetyourpractice’sneeds.Whenprintingoutreports,youcanchoosewhichteststoincludeinthehardcopy.TrackingABI’s,postexercisepressuresandothervascularstud-iesovertimecanbeaccomplishedviagraphs.WhencombinedwiththeMD35andtheTD312cuffinflator/softwareremotecontrol,thecliniciancaninflate/deflatecuffsaswellasenterdataandnavigatethesoftwareremotely.
ThissoftwareisalsocompatiblewithlegacydevicesfromHokanson.Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
TD312 Cuff Inflator and Software Remote Control TheTD312isidealforinflatingcuffsfortheMD35.Thethumbwheelispushedforward(awayfromyou)toin-flateandpulledtowardsyoutodeflate,withnomanualpumping,makingcuffinflationeasy.Therechargeablebatterymakesthisautomatedcuffinflatorreadyatalltimes;justrechargeovernightwhenthebatterydisplaysaysthechargeis11Voltsorunder.Afullychargedbatterypackreads14Voltsonthedisplay.WhenusedwiththeNIVP3ArterialandVenousSoftwareitprovidesahandysoftwareremotecontrolandfacilitatesthepressuresandwaveformdataentrybypushingtheStorebutton.Thecomputerinterfaceisavailablewithei-therawirelessRF(radiofrequencyUSonly)orawiredconnection(DataLink).Itcaninflateanysizecuffandrememberthepressureforyou.ThemetalmaleLuerfittingfitsallcuffswithafemaleLuerfittingandtheMV10CuffSelector.
— Rechargeable battery makes it ready at all times
11
A completesetofcuffsisofferedintheCVS4productline.YoucanpurchasetheoptionalSegmentalPressurePackageorpurchasespecificcuffsbasedonyourneeds.OurcuffsareofthedistinctiveHokansonbluewithourlogoonthem;theyofferexceptionalquality,durabilityandfit.
ThefollowingtypesofcuffsareapplicablefortestsperformedbytheMD35.AllofthesecuffshaveafemaleLuerfittingforinflationandwillworkwiththeDS400orTD312withorwithouttheMV10Cuffselector.
TheStraightSegmentalCuffsareusedinmanyexams.Choosecuffsizesaccordingtothelimbcircumference.Cuffsshouldbe20%widerthanthediameterofthelimbwhereyouwillbeapplyingthecuff.Thewrongsizedcuffwillgiveanincorrectpressure.
Afterremovingthebladders,thesecuffscanbewashedinawashingmachineongentlecyclewithsoap.Linedryandwhencompletelydryinsertthebladder.Bladdersandcoversarereplaceable,andcanbepurchasedfromHokanson.
Straight Segmental Cuffs
Contoured Cuffs
SC10TM 11x85cm Upperarmandlowerlegforsegmental pressuremeasurementsandpulse volumerecordings,fourcuffmethod.
SC12TM 13x85cm Upperarmandupperlegforsegmental pressuremeasurementsandpulsevolume recordings,fourcuffmethod.
SC12LTM 13x124cm Upperthighforsegmentalpressure measurementsandpulsevolumerecordings, fourcuffmethodonlargepatients.
SC5TM 6x83cm Armorlegtourniquetcuff.
TMC7TM 7.5x40cm Metatarsusorwrist.
CC17TM 18x108cm Smalltomiddleadultthighforstandard thighbloodpressures,plethysmography, segmentalpressuremeasurementsandpulse volumerecordings,threecuffmethod.
CC22TM 24x122.5cm Largeadultthighforstandardthighblood pressures,plethysmography,segmental pressuremeasurementsandpulsevolume recordings,threecuffmethod.
Vascula
r
MD35 Cuffs Exceptional durability and fit
Model Overall Cuff Size Cuff Application
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 12
D urabledigitcuffscanbeusedforalldigitorpeniletesting.Pleasenotethatthereisachoicebetweenlatexandlatexfreecuffsinthesamesizes.Likelimbcuffs,digitcuffsshouldfitwellbutnottoosnugortooloose.Thelengthofthedigitcuffshouldbelongerthanthecircumferenceofthedigitwherethecuffwillbeapplied.Itisdesirableforthecufflengthtooverlapitselfinordertoget
anaccuratepressuremeasurement.Digitcuffscanbecleanedbywipingwithasoapandwatersolutionandthenrinsing.
*Donotcleanlatexcuffswithalcoholproducts;itwilldestroythem.
Durable latex free polyurethane cuffs
Durable latex cuff
Formoreinformationandsupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Thermal chart paper
TCPG60(caseof60rolls)andTCPG3(boxof3rolls)arethetwothermalchartpaperoptionsfortheMD35chartrecorder.Thisthermalchartpapercomeswiththegridpre-printedonit.
Formoreinformationandsupportingdocumentspleasegotoourwebsite:www.hokanson.cc
MD35 Cuffs Digit or penile testing
UDC1.6TM 1.6x9cm Smalltoesandfingers.
UDC1.9TM 1.9x9cm Middletoesandfingers.
UDC2.5TM 2.5x9cm Largefingersandmiddletoes.
UPC2.5TM 2.5x12cm Largetoeorpenis.
UPC3.3TM 3.3x12cm Verylargetoeorpenis.
DC1.6TM 1.6x9cm Smalltoesandfingers.
DC1.9TM 1.9x9cm Middletoesandfingers.
DC2.5TM 2.5x9cm Largefingersandmiddletoes.
PC2.5TM 2.5x12cm Largetoeorpenis.
PC3.3TM 3.3x12cm Verylargetoeorpenis.
Model Overall Cuff Size Cuff Application
13
Vascula
r
RD2 Rapid Cuff Deflator
TheRD2plungerrapidlyexhauststheairfromavascularcuffforvenousoutflowmeasurements;itcanbeusedwiththecontouredthighcuffsandrapidversionstraightcuffs.ItworkswellwitheithertheDS400ortheTD312inflator.Pushingintheplungerquicklydeflatestheattachedinflatedcuff.
TheRD2usesthesameuniqueconnectionsystemastheE20RapidCuffInflatorformaximumexhaustrate.
Formoreinformationandsupportingdocumentspleasegotoourwebsite:www.hokanson.cc
MV10 Segmental Cuff Selector TheMV10facilitatesrapidswitchingfromonecufftoanotherforpulsevolumerecordings(PVR’s),segmentalpressureexams,orevenspeedingupanABIexam.TheMV10iscompatiblewiththeTD312ortheRS400.
ThecuffinflatorattachestotheconnectoratthebaseoftheMV10andupto10cuffscanbeconnectedtothehoses.Toswitchbetweencuffstoinflateanddeflate,flipthetoggleswitch.NopowerisrequiredanditfitsallsizesandtypesofHokansonvascularcuffs. — No power required and fits all sizes and types of
Hokanson vascular cuffs
UDC1.6TM 1.6x9cm Smalltoesandfingers.
UDC1.9TM 1.9x9cm Middletoesandfingers.
UDC2.5TM 2.5x9cm Largefingersandmiddletoes.
UPC2.5TM 2.5x12cm Largetoeorpenis.
UPC3.3TM 3.3x12cm Verylargetoeorpenis.
DC1.6TM 1.6x9cm Smalltoesandfingers.
DC1.9TM 1.9x9cm Middletoesandfingers.
DC2.5TM 2.5x9cm Largefingersandmiddletoes.
PC2.5TM 2.5x12cm Largetoeorpenis.
PC3.3TM 3.3x12cm Verylargetoeorpenis.
Model Overall Cuff Size Cuff Application
— Pushing in the plunger quickly deflates the attached inflated cuff
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 14
P ortable,compactandeasytouse:TheMD6Systemisacompletephysiologicalperipheralvasculartestingsystemthatyoucantakeanywhere.Itisnotcomputerizedandhasastripchartrecorderforeasydocumentation.Thechartrecorderpaperhasanadhesivebackingsoyoujustprintandpressonthepatientrecord.BoththeDopplerandChartRecorderrunonrechargeablebatteriesso
youdonotneedACpowerwhenusingthesystem.
MD6 Bidirectional Continuous Wave Doppler At9ouncestheMD6isasmall,compactpocketDoppler.ThehighqualityaudiosignalusesDynamicNoiseReduction(DNR®)andiseasytohear,eveninanoisyroom.ThepatentedredandgreenLEDsontheendoftheDopplerprobeshowyouvisuallywhentheprobeisoverthebestplaceforasignal.Greenmeansflowtowardstheprobeorarterialblood.Whentheprobeisoveraveinordetectsretrogradeflow,theredLEDlightstoindicateflowawayfromtheprobe.Togetanaudiostereoeffectfordistinguishingbloodflow,purchasingop-tionalstereoearphonesallowsyoutohearflowtowardstheprobeintheleftearandflowawayfromtheprobeintherightear.
ThecontrolsforDoppleron/offandchartrecorderon/offareconve-nientlyontheprobeforeasyaccesswithyourindexfingerorthumb.TheDopplerusesrechargeableNiCadbatteriesandischargedseparatelyfromthechartrecorder.WheninsertedontheinputjackoftheMD6VRchartrecorder,thewaveformsfromtheDopplercanberecorded.
MD6 System Portable, easy to use
— The red and green LEDs show the best place for a signal
15
MD6RP Photo Plethysmograph
TheInfraredbasedPPGphotoplethysmographfacilitatesdigitpressuresandwaveformswitheaseandaccuracy.ThediodeshaveaVelcroattachmentforsecurefittingtodigits.Theplethysmo-graphplugsintotheinputjackanddrawsitspowerfromthechartrecorder.
MD6PN Pneumo Plethysmograph
TheMD6PNfacilitatespulsevolumerecordingsbydetectingpressurechangesinasensingcuffappliedtothepatient’slimb.Thepulsevolumerecordingwaveformshapesandamplitudescanbecomparedbetweensitesonthepatient’sbodytoindicatethesegmentwherediseasemaybepresent.TheMD6PNplugsintotheinputjackonthechartrecorderanddrawsitspowerfromtheMD6VR.Realtimewaveformsandbloodflowinformationareproducedforhardcopyclinicalreports.
MD6VR Chart Recorder
TheMD6VRcreatesareal-timechartrecordingofbloodflowinformationorwaveformsdirectlyfromthefollowinginstruments:theMD6Doppler,theMD6RPPhotoPlethysmo-graphandtheMD6PNPneumoPlethysmograph.Thischartrecorderhasrechargeablebatteriessoyoucanuseitanywhere.ThecontrolsaresimplesoftbuttonsandanLEDbargraphindicatesthewaveformpositionandreflectspulsation.Thereare5printspeedsettings,sixrangesettingsforplethysmographsandthreerangesettingsfortheDoppler.Dateandtimeareprintedatthestartofeachrecordingandthechartrecorderspeedandrangearealsoprintedalongtheedgeofthechartpaper.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Vascula
r
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 16
TD312 Calculating Cuff Inflator
T heTD312CalculatingCuffInflatorisidealforbusypracticesorlargescreeningclinics.Thethumbwheelispushedforward(awayfromyou)toinflatetheattachedcuff,andpulledtowardsyoutodeflatewithnomanualpumping,makingcuffinflationeasy.Therechargeablebatterymakesthisautomated
cuffinflatorreadyatalltimesduringyourbusyday,andcanbelefttochargeovernight.WhenusedwiththeNIVP3ArterialandVenousSoftwareitprovidesahandysoftwareremotecontrol.TheTD312canstorepressuresandperformtheABIcalculationsforyou;thisisveryusefulwhendoingABIscreeningexams.ItcaninflateanysizecuffandrememberthedetectedpressureforyouandcalculatetheABI.ThemalemetalfittingfitsallstandardHokansoncuffsandtheMV10CuffSelector.
Fortakingsegmentalpressures:duringdeflationofthecuffwhentheDopplersignalreturnsateachsite,pushtheStorebuttontosavethepressurereading;upto12pressurescanbestoredinthememory.YoucanrecallthestoredpressureswheninmemorymodeaswellasselectthepressurestousetocalculatetheAnkleBrachialIndexorToeBrachialIndex.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Thermal Chart PaperTCP105cmwideplainpaperforMD6VRandlegacyMD6R(packageof10rolls)
ADP105cmwideplainadhesivebackedpaperforMD6VRandlegacyMD6R(packageof10rolls)
ChartpaperisavailablefortheMD6VRChartRecorder.TheMD6VRhastheoptionofadhesivebackedthermalchartpapersoyoujustprint,removethebackingandadhereittothepatientrecordwithnomoretapingorpastinganditadheressowellthatitcannotberemoved.
Formoreinformationpleasegotoourwebsite:www.hokanson.cc
— No more taping or pasting. Adheres so well it cannot be removed.
TCPI0 ADP10
17
MD6 Doppler
At9ounces(250grams)theMD6isacompact,convenientpocketDoppler.ThehighqualityaudiosignalusesDynamicNoiseReduction(DNR®)andiseasytohear,eveninanoisyroom.ThepatentedredandgreenLEDsontheendoftheDopplerprobeshowyouvisuallywhenyouareonthearteryatthebestplaceforasignal(itflashesabrightgreenLEDlightwhichisbrightestwhenyouareonthe“sweetspot”).Greenmeansflowtowardstheprobeorarterialblood.WhentheprobeisoveraveintheLEDflashesredtoindicateflowawayfromtheprobe.Togetanaudiostereoeffectfordistinguishingbloodflow,purchasingoptionalstereoearphonesallowsyoutohearflowtowardstheprobeintheleftearandflowawayfromtheprobeintherightear.
ThecontrolsforDoppleron/offandchartrecorderstart/stopareontheprobe.TheDopplerusesrechargeableNiCadbatteriesandischargedseparatelyfromthechartrecorder.Wheninsertedonthein-putjackoftheMD6VRchartrecorder,thewaveformsfromtheDopplercanberecorded.
MD6 Pocket Doppler with Detachable Transducer
This“twin”totheMD6Dopplerhasadetachablecablethatis6feet(1.8meters)long.Thecontrolsandre-chargeablebatteryareidenti-caltotheMD6Doppler.ItcanalsobeusedwiththeMD6VRchartrecorderforprintingwaveforms.
HandheldorpocketDopplers:theMD6andtheMD6withDetachableTransducerDopplersareidealforlocatingdifficulttofindpulsesorcheckingpostoperativepulsesonvascularstentsorrevascularizedsites.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Vascula
r
TD312 Calculating Cuff Inflator Dopplers To find the hardest pulse
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 18
ImproveyourduplexscanningforVenousRefluxorVenousInsufficiencywiththeRapidCuffInflationSystem.GetreproducibleresultsandcatchtherefluxmissedwhenusingeitherValsalvaorhandaugmentation.TheHokansonE20eliminatessquattingtosqueezethepatient’sleg,compressingallofthesofttissue,holdingitforpreciselythecorrectamountoftimeandrapidlyreleasingthepressure
whileyouscanthelegforvenousreflux.Thereisnoneedforasecondpersontodothecompression,reducingtheexpenseofperformingthistest.TheE20inflatesanycuffin0.3sec,holdsthepressureindefinitelyorforwhatevertimeyourprotocolneedsandtheninstanta-neouslydeflatesthecuff.Itworkseverytimenomatterthesizeofthecufforlimb.Simplydialinthepressureneededandpushthebuttonforinflationandthenpushthebuttontodeflate.
TheE20’slargedigitalreadoutdisplayscuffpressuresaccuratelytowithin1mmHgoverarangeof0to300mmHg.TheE20requiresasourceofcleancompressedairandtheAG101istheperfectcompanion.TheAG101hasthecapacitytoallowtheE20toinflatealargecontouredthighcuffevery12secondsindefinitely.Specialcarehasbeentakentomakethecompressorquiet,compactanddependablesoitisideallysuitedforyourexamroom.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
AlongwiththeRapidCuffInflationSystemyouselecttheoptiontohavea3-SecondTimeroraFootSwitchandalsothecuffsthatyouwillneedtomeetyourpatientneeds.
3-Second Timer SetthepressureontheE20andwhenyouarereadytoscanthelegjustpushthebut-tononthe3-SecondTimerandthecuffinflatesin0.3second,holdsthepressurefor3secondsandthendeflatesinstantaneously;itisaccurate,reliableandeasy.Noneedforasecondpersonandnoworriesabouttheconsistencyorreproducibilityandaccu-racyofthepressure,timingorresults.Savestime,moneyandyourback.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Rapid Cuff Inflation System
— No need for a second person to do the compression, reducing costs
19
Foot Switch TheFootSwitchprovidesremoteinflation/deflationwheneveryouneedit.SteppingontheFootSwitcheitherinflatesordeflates,keepingyourhandsfreeforothertasks.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Rapid Version Cuffs RapidVersionCuffshavelargeinnerdiametertubingsothecuffcaninflateanddeflatealmostinstantaneously.Theyarenotdesignedfortakingstandardbloodpressures,orforusewithLuerfittings.
Rapid Version Straight Segmental Cuffs
Forlargelegsandarmsthattaper,thiscuffgivesabetterfitwithevenpressureapplicationaroundthelimb.Tousewiththerapidcuffinflationsystem,cutofftheLuerfittingsonthelargetubing.
Contoured Cuffs
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
SC10DTM 11x85cm Upperarmandlowerlegfor plethysmographyandvenousreflux measurements.
SC12DTM 13x85cm Upperarmandlowerlegfor plethysmographyandvenousreflux measurements.
CC17TM 18x108cm Smalltomiddleadultthighforstandard thighbloodpressures,plethysmography, segmentalpressuremeasurementsandpulse volumerecordings,threecuffmethod.
CC22TM 24x122.5cm Largeadultthighforstandardthighblood pressures,plethysmography,segmental pressuremeasurementsandpulsevolume recordings,threecuffmethod.
Phlebolog
y
Rapid Cuff Inflation System
Model Overall Cuff Size Cuff Application
Fitted with “D” version tubing
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 20
Portable ABI Kit Everything you need
T heABIisaneasy,noninvasiveexamforperipheralarterialdisease(PAD)screening.ThisexamisrecommendedbytheAmericanDiabetesAssociation,theAmericanHeartAssociation,theAmericanCollegeofCardiologyandtheAmericanCollegeofPhysi-ciansasabasicscreeningexaminationforPAD.Pleaseseeourwebsite:www.hokanson.ccformoreinformationaboutPADand
ABIscreening.
The Portable ABI Kit ForthePrimaryCareProviderorHomeHealthorClinic,thePortableABIKithaseverythingyouneedtoperformaccurateABI’stoidentifypatientswithPADwhoneedfurtherattention.Resultsaredocumentedinreal-timeviathewaveformprintedonthestripchartrecorder.ThegreencoloredLED’sflashprovidestheclinicianameanstoidentifythe“sweetspot”wherethemaximumarterialflowislocated.
ThisKitprovidesalltheinstrumentsandaccessoriesneededinaconvenientcarryingcaseincludingachartrecorderfordocumentation.ItisidealforclinicsdoingABIscreening,homehealth,physician’sofficesandhospitalsthatwanttoperformscreeningatthebedsideandotherplaceswhereportabilityisneeded.
The Portable ABI Kit includes:
•MD6Doppler:ThiscontinuouswavebidirectionalDopplerdetectsperipheralbloodflowinthearmandankle.ThepatentedredandgreenLEDsontheendoftheDopplerprobeshowyouvisuallywhenthetransducerispositionedoverthearteryatthebestplaceforasignal(itflashesabrightgreenLEDlightwhichisatitsmaximumwhenyouareonthe“sweetspot”).
•MD6VRChartRecorder:Printsreal-timeDopplerwaveformsfromtheMD6(usedfordocumentation).
• Fourstraightsegmentalbloodpressurecuffs:Onecuffforeacharmandoneforeachankle.
•DS400Aneroidsphygmomanometer:Ambidextrous,ruggedcuffinflatorallowseasilycontrolledcuffbleedrate.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
— Ideal for screening at the bedside and other places where portability is needed
21
Primary Ca
re
Portable ABI Kit Everything you need
The TBI Package
TheTBIPackageaddsthetoepressuretothePortableABIKitsopatientswithabnormallyhighABI’s(typicallythosegreaterthan1.3)canbeexaminedproperly.Calcificationofthearterialbloodvesselsinthelegscauseanabnor-mallyhighABIandtheyarenotconsideredaccurate.Forthesepatients,theToeBrachialIndex(TBI)givesanaccurateassessmentofthepresenceofPADbyusingphotoplethysmographytodetectpulsesandsystolicpressuresontoes.Itiseasytoperformandnecessaryforevaluationofpatientswithcalcifiedvessels.ItusestheChartRecorderfromthePortableABIKit.Itcanfitintothecarryingcaseforeasytransport.
Formoreinformationandsamplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Toe Pressure Kit
ToePressuresareanexcellentperipheralarterialcheckfordiabeticpatients,especiallythosewithwoundsorulcersontheirlegsorfeet.Thiseasytousekitiscompletelyportableandyoucandocumenttheassociatedwaveformforcomparisonovertime.Itcontainsthephotoplethysmograph,phototransducer,cuffs,chartrecorder/batterycharger(chartpaper),carryingcaseandaneroidsphygmomanometer.Thiskitisexcellentforevaluatingpatientswithcalcifiedvessels,non-healingwounds,diabeticfeetorpeoplewhoneedtoepressures.
— Excellent for the needs of diabetic patients
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 22
TD312 For busy practices or clinics
T heTD312isidealforbusypracticesorlargescreeningclinics.Thethumbwheelispushedforward(awayfromyou)toinflateandpulledtowardsyoutodeflate,withnomanualpumping,makingcuffin-flationeasy.Therechargeablebatterymakesthisautomatedcuffinflatorreadyatalltimes;justrecharge
overnight.WhenusedwiththeNIVP3ArterialandVenousSoftwaretheTD312alsoprovidesahandysoft-wareremotecontrol.Whenusedasastandalonecuffinflator,orwithotherHokansonproducts,theTD312canstorepressuresandperformtheABIcalculationsforyou;thisisveryusefulwhendoingABIscreeningexams.Itcaninflateanysizecuffandrememberthepressureforyou.ThemalemetalfittingfitsallstandardHokansoncuffsandtheMV10CuffSelector.
Fortakingsegmentalpressures:duringdeflationofthecuffwhentheDopplersignalreturnsateachsite,youpushtheStorebuttontosavethepressurereading;upto12pressurescanbestoredinthememory.Youcanrecallthestoredpressureswheninmemorymodeaswellascalculatethepressureindices,suchastheABIandTBI.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Handheld Dopplers
MD6 Doppler At9ounces(250grams)theMD6isacompact,convenientpocketDoppler.ThehighqualityaudiosignalusesDynamicNoiseReduction(DNR®)andiseasytohear,eveninanoisyroom.ThepatentedredandgreenLEDsontheendoftheDopplerprobeshowyouvisuallywhenyouareonthearteryatthebestplaceforasignal(itflashesabrightgreenLEDlightwhichisbrightestwhenyouareonthe“sweetspot”).Greenmeansflowtowardstheprobeorarterialblood.WhentheprobeisoveraveintheLEDflashesredtoindicateflowawayfromtheprobe.Togetanaudiostereoeffectfordistinguishingbloodflow,purchasingoptionalstereoearphonesallowsyoutohearflowtowardstheprobeintheleftearandflowawayfromtheprobeintherightear.
ThecontrolsforDoppleron/offandchartrecorderstart/stopareontheprobe.TheDopplerusesrechargeableNiCadbatteriesandischargedseparatelyfromthechartrecorder.WheninsertedontheinputjackoftheMD6VRchartrecorder,thewaveformsfromtheDopplercanberecorded.
23
MD6 Pocket Doppler with Detachable Transducer
This“twin”totheMD6Dopplerhasadetachablecablethatis6feet(1.8meters)long.Thecontrolsandre-chargeablebatteryareidenticaltotheMD6Doppler.ItcanalsobeusedwiththeMD6VRchartrecorderforprintingwaveforms.
Handheld or pocket Dopplers:theMD6andtheMD6withDetachableTransducerDopplersareidealforlocatingdifficulttofindpulsesorcheckingpostoperativepulsesonvascularstentsorrevascularizedsites.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
UW7 Doppler
TheUW7DopplerprovidesbotharemovableDopplertransducerwithanextralongcableandalargespeakerforexcellentsound.ThisDopplerisveryusefulinateachingsituationwheretheinstructorcanlocatethepulseandallofthestudentshearthesoundsimultaneously.TheUW7doesnothaveanyprintcapabilities.
TD312 For busy practices or clinics
— Useful in teaching situations where students hear pulse sounds simultaneously
Primary Ca
re
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 24
The AI6 A complete automated system
AI6 Automated Strain Gauge Plethysmography System
T heAI6istheidealarterialinflowsystemforresearcherswhowantacompletelyautomatedsystemwitheverythingneededtoperformthemostadvancedstraingaugeplethysmographytestingavailabletoday.
Usingbuiltinprotocolsyoucontrolthevariablesandcaneasilyreplicatethetestwithmultiplepatients.Youcancreateyourownstandardprotocolseasilyandsavethemforfutureuse.TheAI6isthesolutionforsimplifyingandautomatingbilaterallimbbloodflowstudies.OncetheprotocolsaresettoyourspecificationsandthepatientpreparedtheAI6doestherestforyou.AnECGinputisusedtosynchronizethevenousocclusioncuffwiththepatient’sheartbeattoimprovetheconsistencyofthemeasurements.Aninvasivearteriallinecanbeusedtocalculatearterialresistance.Alltestingisbilateralandsomeresearchersuseonelimbasthecontrolfortheexperi-ment.Thereisawiderangeoftestprotocoloptions,allintheresearcher’scontrol.Alltestdataisstoredforyoutoreviewandthesoftwareassistsyouwiththeinflowratemeasurementsanddataanalysis.Oncedataisacquired,itisstoredinadatabaseforeasyrecall,editandreportprint-outs.
TheAI6comeswithstandardprotocolsformeasuringarterialinflowinoneortwolimbssimultaneouslyincludingautomaticreactivehyperemiatesting.Youcancontroltheinflationtimesanddurationsandthesoftwarecontrolstheinstrumentsandrecordsthemeasurementsautomaticallybasedonyoursettings.
The AI6 includes:
•Twostraingaugeplethysmographs
•Twocuffinflatorsforinflationoffourcuffs,totwoseparatepressures
•OneECGamplifierfortiming
•Oneinvasivearterialpressuretransducer
•Oneauxiliaryanaloginputformeasurementofanextraparameter
Features that simplify testing:
•Twochannelsofcalibratedstraingaugeplethysmographytomeasuretwolimbssimultaneously.
•R-Wavetrigger.AnECGamplifierdetectsthepatient’sheartbeatandtheAI6inflatesthecuffsattheselectedpointintheheartcycle.Theresultinginflowmeasurementsareeasierandmorerepeatable.
•Allinstrumentcontrolsareonthecomputerscreen,makingiteasytoadjustcuffpressures,balancetheplethysmographs,pauseandrestartmeasurementsandaddtestcommentstothedata.
Formoreinformation,samplereportsandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
25
EC6 Strain Gauge and Photo Plethysmograph
TheEC6providesresearcherswiththeabilitytobuildtosuittheinstrumentationtheyneedforusingeitherstraingaugeorphotoplethysmographyforarterialinflow,venoustestingandawidevarietyofmeasurementapplications.Thisisthelowestcoststraingaugeplethysmographwithin-situelectricalcalibration;thisconceptwasinventedbyHokansonandisunique.Ithasbecomewellacceptedandisanindustrystandard.HokansonhasbothMercuryandIndium-Galliumstraingaugesforlimbsanddigitsandcanbuildtosuitspecialorders.TheEC6supportsaHokansoninfraredphototransducerforpulsedetection,foruseinbloodpressureandvenousrefluxtesting.Choosethedocumentationmethodthatbestsuitsyour
application:TheRS232digitaloutputconnectstoNIVP3SoftwarefordocumentationandautomatedcontrolsofE20/AG101orcon-necttotheirownthirdpartysoftwareapplication.Theanalogoutputallowsconnectivitytoawiderangeofbothsoftwareorstripchartrecorderoptionsfromthirdparties.
TheEC6analogoutputmaybeACorDCcoupledforarterialandvenoustests.Theoutputisadjustablefrom±200mV,andsevensensitivityrangesspan2%(8%fullscale)to0.02%volumechangeperdivisiononthemeter.Autobalanceisavailablewhichresetsthesignalwheneveritgoesbeyondthescaleoftheinstrument’smeter.Calibrationandzeroingoftheoutputisperformedwithonebuttonorbyaremotesignal.
The NIVP3 Segmental Arterial & Venous Exams SoftwarecanbeusedwiththeEC6Plethysmographtoperformpenilepressuresandplethysmography,venousreflux,andmaximumvenousoutflow(MVO)exams.
E20/AG101 Rapid Cuff Inflation System TheE20/AG101canbeusedinconjunctionwiththeEC6forarterialinflowtest-
ing.TheE20providesnearlyinstantaneousvenousoutflowfacilitatingtheEC6’smeasurementofthearterialinflowrate.TheE20/AG101alsodeflatesacuffin-stantaneouslysothatitcanbeusedforthemaximumvenousoutflow(MVO)exam.TheE20/AG101maybeusedtoperformreactivehyperemia,asitsregulatorwillmaintainthesetcuffpressureaslongasisdesired.WhenusedwiththeNIVP3SoftwareforarterialinfloworMVOtests,youcanautomatetheinflation,hold,deflationtomeettheneedsofyourstudy’sprotocol.
• Cycle Timer
TheCycleTimerisoptionallyinstalledinsidetheE20atthefactory.Thecycletimerisidealforarterialinflowstudies,wheretheNIVP3ArterialInflowsoftwareisnotused.TheCycleTimerhastwotimersaccessibleonthefrontoftheinstrument.WiththeCycleTimeryoucanrepeatthecycleofinflation/deflationautomaticallyandindefinitely.FirstselectthepressureforinflationwiththedialontheE20,thenselectatimetomaintaintheinflationandtheintervalbetweeninflationsontheCycleTimerandtheE20willperformthisinflate/hold/deflatecycle.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Resea
rch
The AI6 A complete automated system
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 26
Strain Gauges The industry standard
Hokansonstraingaugesaredesignedwithaunique4-wireconstructionthathasbeentheindustrystandardforover30years.StrainGaugesareavailableineitherMercuryorIndium-Galliumandareorderedbysizeand
type(limbordigit).Thestraingaugesaredesignedsothattheactiveportionofthegaugeisthesameasthecircumferenceofthelimbordigitbeingmeasured.ThisallowstheHokansonplethysmographtorelateresistancechangetovolumechange.Thesizeforlimbstraingaugesshouldbe1-3cmlessthatthecircumfer-enceofthelimbsotheywillstretchslightly.Digitsstraingaugeshouldbe0.5cmlessthanthecircumferenceofthedigit.Straingaugeshaveashelflifeduetooxidi-zationsowebuildthemtoorder,andtheyarewarrantedforoneyear.
Formoreinformationandothersupportingdocumentspleasegotoourwebsite:www.hokanson.cc
Positioning AidsTheactiveportionofthestraingaugeshouldnottouchanythingoutsideofthelimbduringtesting,andthelimbordigitshouldnotmovetopreventartifact.Positioningfoamblockshelpstopositionthepatientinacomfortablewaysotheywillnotmoveduringtest-ing.Allblocksareeasilycleanedandcanwithstandyearsofuse.
PAK8: Aneightpiecesetofcontouredfoamblocksusedtoposi-tionthelegs,arms,handsandfeetforplethysmographystudies.ThePAK8includestwoofeachpieceshownhere.
PAK5: Afivepieceset,similartothePAK8,isdesignedforfore-armplethysmographystudies.ItincludestwoofeachsizewedgeandoneU-shapedblock.
LimbSet Eightgaugesfrom22to36cmin2cmincrementsForearmSet Eightgaugesfrom16to30cmin2cmincrementsDigitSet Sevengaugesfrom4.5to7.5cmin0.5cmincrements
Strain Gauge Sets Sizes
27
Resea
rch
Strain Gauges The industry standard
DS400 Aneroid Sphygmomanometer TheDS400isareliable,sturdyhandheldsphygmomanometerthathasa10yearwarrantyonthecalibration.Thegripisambidextrousandverycomfortable,andthetriggerreleaseiseasytouseandgivesyougoodcontroloverthedeflationrate.Itcaninflateallofourcuffsexceptthosedesignedforrapidcuffinflation(non-Luerfitting).ItcanalsobeusedwiththeMV10CuffSelectorandtheRD2RapidCuffDeflator.
NIVP3 Arterial Inflow Software
TheNIVP3ArterialInflowSoftwaresimplifiesyourtestprotocolsandinflowcalculationsandprovidesyouwiththeautomationofbalancingthestraingaugeplethysmographcuffinflationanddeflation(usingtheE20/AG101),andstoringtheinflowwaveforms.TheNIVP3softwareassistsyouinmakingslopecalculationstomeasuretheinflowrate.Itgeneratespatientreportsthatarecompletewithplethysmographicwaveforms,patientdemographicsandtabulardata.Analyzingthewaveformslopeallowsyoutosetthecursors(includingahotkeyforlocatingtheclosestwaveformpeakstothecursors)andcalculatestheslopebasedonthecursorpositions.
— Comfortable grip and easy to use trigger release
— Generates complete patient reports with waveforms, demographics and tabular data
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 28
MV10 Segmental Cuff Selector
T heMV10facilitatesrapidswitchingfromonecufftoanotherforsegmentalpressures,pulsevolumerecordingsorevenspeedingupanABIexam.ThissegmentalcuffselectorworkswellwithTD312,theDS400ortheE20RapidCuffInflator.ThecuffinflatorattachesatthefemaleLuerconnectoratthebaseoftheMV10andupto10cuffscanbeconnectedtothehoses.Toswitchbetween
cuffstoinflateanddeflate,flipthetogglevalveassociatedwiththeappropriatecuff.NopowerisrequiredanditfitsallofthesizesandtypesofvascularcuffsviathemaleLuerfittingoneachhose.
RD2 Rapid Cuff DeflatorTheRD2plungerreleasestheairfromavascularcuffrapidlyandcompletelyforvenousoutflowmea-surements;itcanbeusedwiththecontouredthighcuffsandrapidversionstraightcuffs.TheRD2alsoworkswellwitheithertheDS400ortheTD312.Pushingintheplungerquicklyexhauststhepressurefromtheattachedcuff.TheuniqueconnectionsystemthatisalsousedfortheE20RapidCuffInflatorprovidesmaximumcuffexhaustrate.NotethattheRD2isnotrequiredifyouareusingtheE20RapidCuffInflator.
Accessories & Cuffs A full line
— Works well with either the DS400 or TD312
29
Vascular CuffsHokansonistheprimarymanufacturerofvascularcuffsforthevascularcommunity,andourdistinctiveHokansonbluecuffshavebecomethestandardforperipheralvasculartestingforbothclinicalandresearchuse.Theyofferexceptionalquality,durabilityandfit.Wehaveavarietyofsizesandtypesfromstraightsegmentalforarmsandlegstodigit/penilecuffswithandwithoutlatex.AllHokansoncuffshaveafemaleLuerfittingforusewiththeTD312orDS400cuffinflatorswithorwithouttheMV10CuffSelector.AdditionallyHokansoncanmanufacturecustomcuffs,formoreinformation,pleasecallore-mailuswithyourneeds.
Whencuffsarewashed,thebladdersshouldberemovedfirst.Thebladdersshouldnotbereplaceduntilthecuffsarecompletelydry.Thevascularcuffbluecoverscanbewashedongentlecycleinawashingmachinewithmildsoap(rinsewell)andthenlinedried.NEVERAUTOCLAVEACUFFasthiswilldestroyit.
Straight Segmental CuffsAllsegmentalcuffsarelatexfreeandhaveareplaceablepolyurethanebladderandwashablebluenyloncover.Fitisimportantsomeasureeachpatient’slimbinrelationshiptothecuff.Thecuffwidthshouldbe20%largerthanthelimbdiametertocompressallofthesofttissueevenlyandcompletely,andtoprovideanaccuratebloodpressuremeasurement.Alwaysputthecuffsonstraightandsnuggly,butnottight.
Contoured CuffsContouredCuffsprovidebetterfitforlargetaperinglegsorupperarms.TousewithE20RapidCuffInflationSystemortheRD2RapidCuffDeflator,cutoffthefemaleLuerfittingandplugontheendofeachhose.Contouredcuffsarealsolatexfreeandhaveareplaceablepolyurethanebladderandwashablebluenyloncover.
Accessories &
Cuffs
Accessories & Cuffs A full line
SC10TM 11x85cm Upperarmandlowerlegforsegmental pressuremeasurementsandpulse volumerecordings,fourcuffmethod.
SC12TM 13x85cm Upperarmandupperlegforsegmental pressuremeasurementsandpulsevolume recordings,fourcuffmethod.
SC12LTM 13x124cm Upperthighforsegmentalpressure measurementsandpulsevolumerecordings, fourcuffmethodonlargepatients.
SC5TM 6x83cm Armorlegtourniquetcuff.
TMC7TM 7.5x40cm Metatarsusorwrist.
CC17TM 18x108cm Smalltomiddleadultthighforstandard thighbloodpressures,plethysmography, segmentalpressuremeasurementsandpulse volumerecordings,threecuffmethod.
CC22TM 24x122.5cm Largeadultthighforstandardthighblood pressures,plethysmography,segmental pressuremeasurementsandpulsevolume recordings,threecuffmethod.
Model Overall Cuff Size Cuff Application
Model Overall Cuff Size Cuff Application
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 30
Rapid Version Cuffs
RapidVersionCuffsareessentialtosuccessfulrapidcuffinflationforvenousrefluxorinsufficiencytests,aswellasforarterialinflowstudies.ThelargeinnerdiametertubingfacilitatesalmostinstantinflationanddeflationwiththeE20/AG101RapidCuffInflationSystem.ThesecuffsaremadeforusewiththeE20/AG101orRD2RapidCuffDeflator,anddonotcomewithanyLuerfittings.
All new Hokanson cuffs come with durable polyurethane air bladders. Replacement bladders can also be purchased separately, for your straight, contoured, and rapid version cuffs.
Replacement BladdersReplacementbladdersaddtothelongevityofyourcuffs.Bladderscharacteristicallydonotlastaslongasthecovers,soyoucanpurchasereplacementbladdersforthosecovers.
Specialized Cuffs Rapid version, digit, penile
SC10DTM 11x85cm Upperarmandlowerlegfor plethysmographyandvenousreflux measurements.
SC12DTM 13x85cm Upperarmandlowerlegforplethysmography andvenousrefluxmeasurements.
SC10RBTM 10x41cmSC12RBTM 12x41cmSC12LRBTM 12x56cmSC5RBTM 5x41cmTMC7RBTM 6.5x23cmCC17RBTM 17x65cmCC22RBTM 22x69.5cm SC10DRBTM 10x41cmSC12DRBTM 12x41cm
SC10TMStraightSegmentalCuffSC12TMStraightSegmentalCuffSC12LTMLongStraightSegmentalCuffSC5TMTourniquetCuffTMC7TMTransmetatarsalCuffCC17TMContouredThighCuffCC22TMContouredThighCuffSC10DTMRapidVersionStraightCuffSC12DTMRapidVersionStraightCuff
Fitted with “D” version tubing
Model Overall Cuff Size Cuff Application
Model Overall Bladder Size Bladder Application
31
Accessories &
Cuffs
Specialized Cuffs Rapid version, digit, penile
Digit and Penile CuffsDigitandPenilecuffsaremadetofitcorrectlyandsecurely.Theyareusedfortakingmeasurementswithphotoandpneumoplethysmographsaswellasstraingauges.
Thedurablecuffsincludebothlatexandlatexfreepolyurethaneversionsinthesamesizes.ThesecuffshaveoneinlettubewithaplasticLuerfittingforinflationwitheithertheTD312orDS400cuffinflators,withorwithouttheMV10CuffSelector.WithanadaptorDigitandPenilecuffscanalsobeinflatedbytheE20/AG101forcontrolledinflation/deflation.
Disposable Digit or Penile CuffsDisposablecuffsaredesignedforpeaceofmindforyouandyourpatients.Thesedisposablecuffsarepackagedandmeanttobeusedforonepatient;theycanbeusedmorethanonceonapatientandthendisposedproperly.TheyaremadeofPVC(polyvinylchloride)andhaveawhitelatextubewithafemaleLuerfittingforconnectionwiththeTD312orDS400cuffinflator.Theyarepackagedindividu-allyandcomeinpackagesof10,25or100.
Durable latex free polyurethane cuffs
Durable latex cuff
UDC1.6TM 1.6x9cm Smalltoesandfingers.
UDC1.9TM 1.9x9cm Middletoesandfingers.
UDC2.5TM 2.5x9cm Largefingersandmiddletoes.
UPC2.5TM 2.5x12cm Largetoeorpenis.
UPC3.3TM 3.3x12cm Verylargetoeorpenis.
DC1.6TM 1.6x9cm Smalltoesandfingers.
DC1.9TM 1.9x9cm Middletoesandfingers.
DC2.5TM 2.5x9cm Largefingersandmiddletoes.
PC2.5TM 2.5x12cm Largetoeorpenis.
PC3.3TM 3.3x12cm Verylargetoeorpenis.
Model Overall Cuff Size Cuff Application
Model Overall Cuff Size Cuff Application
DP2.0TM 2.1x12.1cm Largeandmiddletoes,orpenis. DP2.5TM 3.0x12.1cm Largetoeorpenis.
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 32
Vascular Cuff Sets A wide selection
V ascularCuffSetsweredesignedtomeetthegeneralneedsofperipheralvascularexamswithagoodselectionofcuffsfornearlyanysizedlimbordigit.
TheVCS23includesanassortmentofcuffsizesandtypestomeettherequirementsofanyvascularlab:twoCC22™andtwoCC17™con-touredThighCuffs;fourSC10™andfourSC12™StraightSegmentalCuffs;twoSC5™TourniquetCuffs;oneTMC7™TransmetatarsalCuff;sixDigitCuffs(twoineachwidth:1.6,1.9and2.5cm);oneUPC2.5™DigitCuffandoneUPC3.3™DigitCuff.
TheVCS14SegmentalVascularCuffSetprovidesallofthecuffsneededtoperformbilateralsegmentalpressuresandpulsevolumerecordings:fourSC10™StraightSegmentalCuffs;sixSC12™StraightSegmentalCuffs;twoTMC7™TransmetatarsalCuffsandtwoUPC2.5™DigitCuffs.
Thermal Chart PaperChartpaperisavailableforboththeMD6VRChartRecorderandtheMD35ChartRecorder.TheMD6VRhastwooptionsforthermalchartpaper.Oneoptionistheadhesivebackedstrippaper,theADP10,thatallowsyoutojustprint,removethebackingthenadhereittothepatientrecordwithnomoretapingorpastinganditadheressowellthatitcannotberemoved.
TheMD35usestheTCPG60andTCPG3thermalchartpaperwithapreprintedgrid.
TheMD6VR(andlegacyMD6R)usestheTCP10andtheADP10thermalchartpaper.TheTCP10andADP10donothaveapreprintedgrid.
TCPI0 ADP10
TCPG60&TCPG3
— No more taping or pasting. Adheres so well it cannot be removed.
33
Vascular Cuff Sets A wide selection A
ccessories & Cuffs
Coupling Gel
GEL60:60gramtubesaresoldinapackageof12tubes.Couplinggelremovestheairbetweenthetransducerandthepatient’sskin;airisapoortransmitterofsoundwaves.Thegelalsoaidsinthepropagationofthesoundwaves.
Positioning Aids•Usefulforholdingpatientsinpositionswhileperformingstraingaugeplethysmography.Theactiveportionofthestraingaugesmust
onlybeincontactwiththelimbtobemeasured.Theseblocksaremadefromdensefoamandcanbeeasilycleansedandwithstandyearsofuse.
• Twochoices:
PAK 8whichincludestwoofeachshapeshownhere.
PAK 5 includestwoofeachwedgesizeandoneU-shapedblock.
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 34
DopplerbloodflowdetectorshavebeenusedinmedicinesincetheirinventioninJapanbySatomurain1948.InnovationsinDop-plertechnologyhaveresultedineasilyportableinstruments,capableofsensingthedirectionaswellasthevelocityandlocationofbloodflow.Doppleroutputisalwaysanaudiosignalwithapitchproportionaltothevelocityofthebloodflowandloudness
proportionaltotheamountofblood.Additionaloutputsincludequadratureaudioforspectralanalysisandanalogsignalsforrecordinghardcopy.Dopplersareusefulinthemeasurementofsystolicbloodpressure,determiningthepatencyofarterialgrafts,tracingindividualarteriesandveins,anddetectingfetalheartbeats.
Direction SensingVascularDopplerswithdirectionsensingcapabilityaretypicallycalledbidirectional.BidirectionalDopplersallowyoutodistinguishbetweenarterialandvenoussignalsbasedonflowdirection,andtoidentifyreverseflowinthearteries.AllHokansonvascularDopplersarebidirectional,anduseavarietyofmethodstoshowthedirectionofflow.
OnedirectionindicatorfoundinmanyofourDopplersisthepatenteduseofredandgreenLEDlightsintheprobetip.Theredlightsilluminatetoindicateflowawayfromtheprobe,andthegreenlightsindicateflowtowardtheprobe.OtherflowdirectionindicatorsinHokansonDopplersareabargraphdisplayandprintedstripchart.Thebargraphdisplayshowsthelevelanddirectionoftheflowsignalthatwillberecordedwhenthechartpaperruns.
SomeofourDopplersalsoprovideanauralindicationofflowdirectionthroughstereoheadphones;flowtowardtheprobeisheardintheleftearandflowawayfromtheprobeintherightear.
Dynamic Noise ReductionDNR®isatrademarkofNationalSemiconductorfortheirpatentednoisereductioncircuitryusedinhi-fiaudioapplicationstoreduceback-groundhiss.WewerethefirsttolicensethistechnologyforuseinaDopplerinstrument.Asaresult,ourinstrumentseliminatehisswithoutusingcommonfilterswhichwouldlimithighfidelityresponse.Accuratediagnosisoftendependsonclear,high-frequencyaudiblesignals.
Doppler For accurate blood pressure
— All Hokanson vascular Dopplers are bidirectional, using a variety of methods to show the direction of flow
35
Aplethysmographisaninstrumentusedtodetermineandregistervariationsinthesizeofanorganorlimb.Evaluationofbloodflowanddiagnosisofvasculardiseasecanbeperformedwithseveraltypesofplethysmographs;eachhasitsownadvantages.Wemanufacturethreetypes:
Photo Plethysmograph (PPG)Thisinstrumentusesinfraredsensorstodetectskincolorchangesthatoccurwitheachheartbeat.
Theoutputofthephotoplethysmographisawaveformshowingvolumechangesinthemeasurementarea.Thisinstrumentistypicallyusedinthedetectionofbloodflowandthemeasurementofbloodpressure.Alimitationisthatvariationsinskincolorandthemethodofapplicationprecludevolumecalibration.
Strain Gauge Plethysmograph (SPG)Athinrubbertube,filledwithMercuryorIndium-Gallium,isplacedaroundthelimbordigitofinterest.Asthevolumeofthelimbchangeswitheachheartbeat,thetubeisstretchedandtheelectricalresistanceincreases.Themeasurementisprocessedandsentasanaloginformationtothedisplayorchartrecorder.
Advantagesofourstraingaugeplethysmographsarethattheyareeasilyandaccuratelycalibratedin-situ,andcanbeusedinawidevarietyofapplications.
Commonusesofthisinstrumentincludemeasuringarterialbloodflowintothelimbsanddigits(sometimescalledvenousocclusionplethysmography),venouscapacitance,maximumvenousoutflowtodetectdeepvenousthrombosisinthelegs,andbloodpressuremeasurementsintheextremities.
Pneumo PlethysmographThisplethysmographdetectschangesinlimbordigitvolumefromthepressurechangesinasensingcuff.Thiscuffisplacedaroundthelimbordigitofinterest,inflatedtoalowpressureandsealedofffromtheinflationdevice.Anychangeinvolumeunderthecuffisreflectedbyapressurechangewithinthecuff.Thisisshownonadisplayorchartrecorder.
Thepneumoplethysmographisgenerallyusedforevaluatingwaveformshapesandrelativeamplitudechanges.Itcanbecalibratedbyaddingorsubtractingaknownvolumeofairtothesystemandobservingthecorrespondingoutputchanges.
Advantagesofpneumoplethysmographyarethatitissimpletouseandcleanwaveformsareeasytoobtain;multiplecuffscanbeappliedtoseveralpartsofthebodyandthenmeasuredinquicksuccession.Usesincludepulsevolumerecording(PVR)andmaximumvenousoutflow.
Doppler For accurate blood pressure Plethysmograph To evaluate bloodflow
1 800.999.8251 fax 425.881.1636 www.hokanson.cc 36
Hokanson Policies
Warranty• Hokansonelectronicinstrumentscarryafiveyearwarranty.Instrumentsarewarranted
againstdefectsinparts,workmanshipandperformanceforaperiodoffiveyearsfromthedateofdeliveryprovidedthattheyhavenotbeenabusedorrepairedbyanunauthorizedperson.
• Transducers,straingauges,bloodpressurecuffsandaccessoriesarewarrantedforoneyear.
• Batteriesareexcludedfromthiswarranty.
• Repairisfreeofchargewhentheinstrumentisreturnedprepaid.Returnshipmentwillbemadeatourexpenseinamannersimilartoyourshipmenttous.Ifforanyreasonweareunabletorepairyourinstrumentwithinthreeworkingdayswewillprovideafreeloanerinstrumentatourexpense.
Service PolicyHokansonwillserviceanyinstrumentwehaveevermanufactured,regardlessofthemanufacturedate.
Rentalandloanerinstrumentsareavailabletothecustomerunderthefollowingconditions:
1. Ifrepairtakesmorethanthreeworkingdays,wewillfurnishafreerentalinstrument(loaner)atourexpense.FreightchargeswillbetheresponsibilityofD.E.Hokanson,Inc.
2. Iftheinstrumentiswithinthewarrantyperiodandthecustomerrequiresarentalinstrumenttocontinuelaboperationsduringequipmentrepair,aloanerwillbeprovidedfreeofcharge,butairfreightchargeswillbetheresponsibilityofthecustomer.
3.Afterthewarrantyperiod,ifthecustomerrequiresarentalinstrumenttocontinuelaboperationsduringequipmentrepair,standardchargesare10%oftheinstrument’svaluepermonth,plusallairfreightcharges.Minimumrentalisonemonth.
TermsPaymenttermsarenet30daysonapprovalofcredit.HokansoncustomerscanalsopayfororderswithVisa,MasterCard,AmericanExpress,prepaymentcheck,wiretransfer,ororderscanbeshippedC.O.D.intheU.S.Pastduebillswillhave1.5%permonthadded.AllpricesquotedareF.O.B.Bellevue,Washington,U.S.A.
Itemsmustbereturnedwithin30daysofdeliveryforcreditandwillbesubjecttoa10%restockingfee.PleasenotifyHokansonpriortoreturninganyitemsforrepairorreplacement.
Minimumorderis$30.00.
Hokanson Policies
12840NE21stPlaceBellevue,WA98005USA
425.882.1689or1800.999.8251fax425.881.1636www.hokanson.cc
How to Perform an ABI
(425) 882-1689 • USA • www.hokanson.cc
Vascular Instruments Vascular Accessories
A complete line of advanced instruments and educational tools for the vascular community of researchers, clinicians, venous and primary care practitioners.
Education
Top Related