Hazardous Materials Incidentsby Chris Hawley
CHAPTER 2: Recognition and Identification
Chapter 2: Overview• Introduction• Location and occupancy• Placards, labels, and markings• Other identification systems • Containers• Use of senses• Chemical and physical properties• Summary
HAZMAT Clues (1 of 2)
• It is through recognition and identification (R & I) that you can impact your ability to stay alive.
HAZMAT Clues (2 of 2)
• Location and occupancy
• Placards, labels, and markings
• Container types• Senses
Location and Occupancy
• The size of the community does not impact the potential for hazardous materials; every community has hazardous materials – Major transportation corridors – Buildings that store chemicals
Some Examples• Hardware stores,
hospitals• Auto part supply stores• Dry cleaners• Manufacturing facilities• Print shops• Doctors’ offices• Photo labs• Agricultural supply stores• Semi-conductor
manufacturing facilities• Electronic manufacturing
• Light to heavy industrial• Marine terminals• Rail yards• Airport terminals and
fueling areas• Pool chemical stores• Paint stores• Hotels• Swimming pools• Food manufacturing• Many others
Placards, Labels, and Markings
• The Department of Transportation (DOT) regulates the movement of hazardous materials (dangerous goods in Canada) by air, rail, water, roadway, and pipeline which can be located in 49 CFR 170-180.
DOT Placarding (1 of 2)
• Table 1 placards– Require placarding at any amount
• Table 2 placards– Require placarding at 1,001 pounds
DOT Placarding (2 of 2)
DOT Hazard Classes (1 of 2)
• DOT has established 9 hazard classes. – Classes 1-8 are specific.– Class 9 is a miscellaneous category.
• Some classes have subdivisions.
DOT Hazard Classes (2 of 2) • Class 1: Explosives• Class 2: Gases• Class 3: Flammable liquids• Class 4: Oxidizers and organic peroxides• Class 5: Flammable solids, water reactives, and
spontaneously reactive• Class 6: Poisons• Class 7: Radioactives• Class 8: Corrosives• Class 9: Miscellaneous hazards
Placards• Fixed on the four sides
of a vehicle
• 10 ¾ by 10 ¾ inches
• Provide warning by:– Color– Division number– Name or UN number– Picture
Labels• Used on two sides of
shipping packages• Affixed near shipping name• 3.9 x 3.9 inches in size• Smaller versions of the
placards• Required for most
hazardous materials packages
Class 1: Explosives• Division 1.1 – Mass explosion hazard
• Division 1.2 - Projectile hazard
• Division 1.3 - Fire hazard or minor blast hazard
• Division 1.4 – Minor explosion hazard
• Division 1.5 – Very insensitive explosives
• Division 1.6 –Also very insensitive explosives
Explosives and Fires
• Extremely dangerous
• Withdrawing usually best option
• Consult DOT ERG
• 1988 Kansas City, MO, lost six firefighters to a fire involving explosives.
Packing Groups• Some materials may not be shipped with
others.
• They have established packing groups.– Packing group I – greatest danger– Packing group 2 – medium danger– Packing group 3 – minor danger
• DOT rules state which materials can be shipped with the various packing groups.
Class 2: Gases (1 of 2)
• Division 2.1 – Flammable gases
• Division 2.2 – Non-flammable, non-poisonous, and compressed gas– Liquefied gas– Pressurized cryogenic gas– Compressed gas in solution
• Division 2.3 – Poisonous gases
Class 2: Gases (2 of 2)
Hazard Zones
• DOT has established hazard zones that signify the amount of toxicity a particular material may present.
• Hazard zones are listed as A-D.• A material listed with “Hazard zone A” is
extremely toxic and presents significant inhalation risk.
• Hazard zone D is also severely toxic, but not as toxic as “A.”
Class 3: Flammable Liquids (1 of 2)
• Flammable liquids are those that have flash points below 141º F.
• Combustible liquids are those that have flash points above 141º F.
Class 3: Flammable Liquids (2 of 2)
Class 4: Flammable Solids (1 of 2)
• Division 4.1 – Flammable solids
• Division 4.2 – Spontaneously combustible materials
• Division 4.3 – Dangerous when wet materials
Class 4: Flammable Solids (2 of 2)
Class 5 Oxidizers and Organic Peroxides
• Division 5.1 - Oxidizers
• Division 5.2 - Organic peroxides
Oxidizers
Organic Peroxides
• Ability to polymerize
• May be violently reactive or explosive
• May violently rupture container, if contained
• Sensitive to shock, heat, or contamination
Organic Peroxides
Class 6: Poisons (1 of 2)
• Division 6.1 – Materials that present a risk to humans during transportation
• Division 6.2 – Microorganisms, or their toxins, that can cause disease
• Has two hazard zones
Class 6: Poisons (2 of 2)
Class 7: Radioactive (1 of 2)
• There are no sub-divisions for radioactives.
• There are three labels.– Radioactive I– Radioactive II– Radioactive III
Class 7: Radioactive (2 of 2)
Class 8: Corrosives (1 of 2)
• Includes acids and bases
• Capable of causing destruction to humans and metal
Class 8: Corrosives (2 of 2)
Class 9: Miscellaneous (1 of 2)
• Present hazard not listed in previous classes– Dry ice– Molten sulfur– Hazardous waste
Class 9: Miscellaneous (2 of 2)
Dangerous Placard (1 of 2)
• Placard means mixed load is being carried.
• Load consists of two materials that would require placarding.
• More than 2, 205 lbs. requires dangerous placard and specific hazard placard.
Dangerous Placard (2 of 2)
Specific Name Placards
Primary Placards
• Provides primary hazard and subsidiary hazard.
• Subsidiary hazard does not have class/division number.
• Subsidiary placard is below primary hazard.
Placard and Identification Numbers
• ID number indicates a bulk shipment.– More than 119 gallons
in one container
Other Placards and Labels (1 of 3)
Other Placards and Labels (2 of 3)
Other Placards and Labels (3 of 3)
White Squared Placard
Labels
• Display primary hazard of the package
• May display subsidiary hazard
Facility Markings: NFPA 704
• Four-tiered system– Health– Fire– Reactivity– Special hazards
• Numerical rating system 0-4
Ratings
• 4 – Severe hazard
• 3 – Serious hazard
• 2 – Moderate hazard
• 1 – Slight hazard
• 0 – Minimal hazard
Hazardous Materials Information System (HMIS)
• On containers
• Used by employers to comply with hazard communication regulation
Military Warning System
Pipeline Marking System
• Pipeline contents
• Pipeline owner
• Emergency contact information
Pesticide Markings
• Label signal words– Danger– Warning– Caution
• Pesticide control #
Containers
• Small, household
• Medium-sized containers
• Large-scale containers
• Fortified containers
Bottles
Bags
Drums• Fiberboard• Fiberboard plastic
lined• Plastic (poly)• Steel• Stainless steel• Aluminum
• Dry, granular• Wetted materials,
slurries• Corrosives• Flammables• Hazardous corrosives• Pesticides or steel
reacting materials
Drums
Cylinders
Totes
Highway Transportation• Box trucks
– Land sea container (sea box)
• Atmospheric tank truck
• Chemical hauler
• Corrosive tank
• Pressurized tanks
• Inter-modal containers
Specification Plate
• Located on tank• Provides specific
information on the tank
DOT 406/MC306 (1 of 2)
• Atmospheric tank truck– Commonly called gasoline tank truck
• 2-5 compartments
• Up to 11,000 gallons
• Aluminum construction
• Elliptical in shape
• Rollover protection
DOT 406/MC306 (2 of 2)
Internal Baffles and Bulkheads
DOT 407/MC307 (1 of 4)
• Chemical workhorse
• Two types– Insulated– Non-insulated
• 2000-7000 gallons (5000 normal)
• Usually one compartment
DOT 407/MC307 (2 of 4)
DOT 407/MC307 (3 of 4)
DOT 407/MC307 (4 of 4)
Insulated 407/307
• Typically one compartment
• Inner tank surrounded by insulation and outer shell
• Steam lines or heated lines in insulation
• Horseshoe shaped
Non–Insulated 407/307
• Reinforced rings
• Typically one compartment
• Round in shape
DOT 412/MC312 (1 of 2)
• Corrosive tank trucks
• Single compartment
• Usually less than 5,000 gallons
DOT 412/MC312 (2 of 2)
MC331 (1 of 2)
• Pressurized tank
• Compressed gases
• Up to 11,500 gallons
• Low to high pressure
• Significant BLEVE risk
MC331 (2 of 2)
BLEVE
• They pose significant risk to responders.
• Fires involving sealed containers can violently rupture.– Propane tanks are common examples
Diagram of a BLEVE
BLEVE Recommendations (1 of 2) • Withdraw immediately in case of rising sound
from venting relief valves or discoloration of the tank.
• Fight the fire from a distance with unstaffed hose holders or monitor nozzles.
• Cool the tank with flooding quantities long after the fire is out.– A minimum of 500 gpm at the point of flame
impingement is recommended by the NFPA.
BLEVE Recommendations (2 of 2) • If the water is vaporizing on contact, you are not putting
enough water on the tank.– Water should be running off the tank if you are cooling the tank.
• Do not direct water at relief valves or safety devices, as icing may occur which would block the venting material causing an increase in pressure inside the tank.
• The tank may fail from any direction, but avoid the ends of the tank.
• For massive fire, use unmanned hose holders or monitor nozzles. If impossible, withdraw from the area and let fire burn.
Dangers Associated with BLEVEs
• The fireball can engulf responders and exposures.
• Metal parts of the tank can fly considerable distance.
• Liquid propane can be released into the surrounding area and be ignited.
• The shock wave, air blast, or flying metal parts created by a BLEVE can collapse buildings, or move responders and equipment.
MC-338 (1 of 2)
• Cryogenic containers
• Vacuum-sealed inner container
• Well insulated
• Low pressure
MC-338 (2 of 2)
Tube Trailers• High pressure cylinders
• Contain compressed gas
Dry Bulk Tanks
Hot Materials Tanks
Intermodal Tanks (1 of 2)
• Non-pressure
• Pressure
• High pressure
Intermodal Tanks (2 of 2)
Rail Tank Cars
• Increased volume– Up to 30,000 gallons
for HAZMAT
• Limited access
Types of Rail Cars• Non-pressure• Pressure• Specialized
Non-pressure Cars (1 of 2)
• Up to 100 psi pressure
• Known as General Service cars
• All piping valves, lines, relief valves on the outside
Non-pressure Cars (2 of 2)
Pressure Cars (1 of 2)
• Over 100 psi pressure
• Liquefied gases
• All pipes, valves, and fittings under a protective dome
Pressure Cars (2 of 2)
Specialized Rail Cars (1 of 3)
• Trailers of flat car
• Box cars
• Cryogenic cars
• Tube cars
Specialized Rail Cars (2 of 3)
Specialized Rail Cars (3 of 3)
Markings on Rail Cars• Placards
• Dedicated cars labeled
• Specifications on side
• Tank car #
Bulk Storage Tanks• Underground
• Aboveground
Gasoline Stations
Ordinary Tank
External Floating Roof
Internal Floating Roof
Specialized Tanks• Cryogenic tanks
• High pressure tanks
Senses
• Touch, taste, smell are dangerous tools to use for recognition and identification.
• Sight and sounds are acceptable, but always maintain distance.
Chemical and Physical Properties
• Follow the science to guide your response.
State of Matter
• Solid
• Liquid
• Gases
Temperature• Melting point
• Freezing point
• Sublimation
Boiling Point• Material turning
to a gas or vapor
Vapor Pressure
• Indication of vapor production
• Material moves to a gas or vapor
• Measure of the force of the vapors
• 760 mm HG = 1 ATM = 14.7 psi
Common Vapor Pressures• Water – 25 mm Hg• Acetone – 180 mm
Hg• Gasoline – 300 mm
Hg• Ethyl ether – 440 mm
Hg• Methyl alcohol – 100
mm Hg
• Diesel fuel – 5 mm Hg• Sodium hydroxide – 1
mm Hg @ 2534º F• Sulfuric acid – 0.001
mm Hg• Ethion – 0.0000015
mm Hg• Sarin – 2.1 mm Hg
Vapor Density
• Relationship with air• Air given value of 1
– Less than 1 rise in air– Greater than 1 stay low
Specific Gravity• Relationship with water
• Water given value of 1– Less than 1 float on water– Greater than 1 sink
Corrosivity
• Acids have a value of 0-6.9.
• Bases are 7.1-14.
• Neutral is a pH of 7.
Common pHs • Water – 7 • Stomach acid – 2• Orange juice – 3• Drain cleaner – 14• Potassium hydroxide – 14• Sulfuric acid – 1• Pepsi – 2• Ammonia - 12
Chemical Reactivity
• Exothermic– Releases heat
• Endothermic– Absorbs heat
Flash Point
• Temperature of the liquid when, while being heated, an ignition source is introduced into the vapor/air mixture located above the liquid, causing a flash fire
Common Flashpoints
• Gasoline – 45º F
• Isopropyl alcohol – 53º F
• Acetone – -4º F
• Diesel fuel – >100º F
• Motor oil 300 – -450º F
• Xylene – 90º F
Autoignition Temperature
• Material is heated and ignites on its own without the presence of an ignition source.
SADT
• Self Accelerating Decomposition Temperature– Temperature at which the material will rapidly
decompose• Usually reacting violently or burning
Flammable Range (1 of 2)
• Lower Explosive Limit (LEL)– Minimum amount in air needed to have a fire
• Upper Explosive Limit (UEL)– Maximum amount in air to have a fire
• Range in between LEL and UEL is the flammable range.
• Fires and explosions occur in the flammable range.
Flammable Range (2 of 2)
Toxic Products of Combustion• When most materials burn, smoke is
usually very toxic.
• Even wood, wool, hay, and many other common items present a significant risk.
• Smoke from plastic burning is extremely toxic.
• Respiratory protection should always be worn in the presence of smoke.
Summary• Hazard classes
• Containers
• Chemical and physical properties
Top Related