7/24/2019 Gould Pumps
1/12
4
CentriPro4" Motors and Controls
AGENCY LISTINGS:
Control BoxMay Replace May Replace May Replace
EnclosureShipping
Order HP KW VoltsGP # RJ # FE #
DimensionsWeight (lbs)
Number W x D x H (in)
CB05412CR 0.5 .37 230 NA
50F311CB 2824055015 8.1 x 5.9 x 9.3 7
S50N1CB, A50N1CB
CB07412CR .75 .55 230 NA
75F311CB 2824075015 8.1 x 5.9 x 9.3 7
S75N1CB, A75N1CB
CB10412CR 1 .75 230 NA
S100F311CB 2824085015 8.1 x 5.9 x 9.3 7
S100N1CB, A100N1CB
CB15412CR 1.5 1.1 230 00074
150F311CB282 3008 110 8.1 x 5.9 x 9.3 7
S150N1CB, A150N1CB
CB20412CR 2 1.5 230 00084
200F311CB282 3018 110 8.1 x 5.9 x 9.3 7
S200N1CB, AS200T1CB
CB30412CR 3 2.2 230 00094
300F311CB282 3028 110 8.1 x 5.9 x 9.3 7
S300N1CB
CB50412CR 5 3.7 230 00104
500F311CB282 1138 110 8.1 x 5.9 x 9.3 8
S500N1CB
CSCR (Capacitor Start-Capacitor Run) Control Box Features
Vltage Rela fr installer cnvenience
230 vlt standard mdels 208 vlt rela, rder n. 9K479 is available fr lw vltageapplicatins
Start Capacitrs fr starting trque
Run Capacitrs fr efcienc and quiet peratin
Tpe 3R enclsure fr indr r utdr munting
Accepts up t #2 AWG wire
Multiple knckuts and tw grund terminals
Higher HP mdels require heav dut pressure switches See Magnetic Cntactr versin t use standard pressure switches
Manual reset verlads n 1 5 HP mdels
Note:208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.
Quick Disconnect Control Box Features
Vltage Relas fr installer cnvenience 115 and 230 vlt mdels
208 vlt rela available fr lw vltage applicatins Start Capacitrs
NEMA 3R enclsure fr indr r utdr munting Multiple knckuts
Quick discnnect cver design will retrt with F.E. Q-D cntrl bxes Tw grund lugs
CentriPro Order Numbers
Control Box
HP KW Volts
Replaces Replaces Enclosure Dimensions Shipping
Order Number old # FE # W x D x H (in) Weight (lbs)
CB05411 .5 .37 115 00043 280 104 49 4.8 x 2.9 x 8.4 4
CB05412 .5 .37 230 00044 280 105 49 4.8 x 2.9 x 8.4 4
CB07412 .75 .55 230 00054 280 107 49 4.8 x 2.9 x 8.4 4
CB10412 1 .75 230 00064 280 108 49 4.8 x 2.9 x 8.4 4
AGENCY
LISTINGS:
UL
C US
ULTESTED To UL AND CSASTANDARDS By UL.
7/24/2019 Gould Pumps
2/12
CentriProQuick Disconnect Control BoxesFor 4", 1, 3-Wire Submersible Motors
ITT Residential Water
FEATURES
Voltage Relays for installer convenience
115 and 230 volt models
208 volt relay, 9K461, available for lowvoltage applications
Start Capacitors
NEMA 3R enclosure for indoor or out-door mounting
Quick disconnect cover design will retro-
fit with F.E. Q-D control boxesMultiple knockouts
Two grounding lugs
AGENCY LISTINGS
CentriPro is a brand of ITT Corporation.
www.centripro.com
Engineered for life
CentriPro
CSA certified to C22.2, No. 108 Standardby Canadian Standards Association,File No. LR38549
Listed to UL778 Standard by UnderwritersLaboratories Inc. File No. E83318
UL
7/24/2019 Gould Pumps
3/12
ITT CENTRIPROResidential Water
2
K REPAIR PARTS FOR QUICK DISCONNECT STYLE CONTROL BOXES*
CentriPro Old Capacitor StartCapacitor Capacitor
StartSupplier
Order Order HP Volts Order CapacitorVoltage Quantity
RelayNumber
Number Number Number Mfd Order No.
CB05411 00043 (GP) .5 115 9K450 250 - 300 125 1 9K457
RVA7AA (6L)(or KL)
CB05412 00044 (GP) .5 230 9K448 59 - 71 220 1RVA2AL (6L)
CB07412 00054 (GP) .75 230 9K449 86 - 103 220 1 9K462(or KL)
CB10412 00064 (GP) 1 230 9K447 105 - 126 220 1
Special 208 V Relay for .5 - 1 HP operating on 200 or 208 volt power supplies Order No. 9K461.
* Repair parts above will work in new voltage relay control boxes as well as in control boxes shown in "ReplacesColumn" above.
Note:208 Volt starting relay, 9K461, is available for 200-208 volt power supplies.
CENTRIPRO ORDER NUMBERS
Control Box ReplacesReplaces
StandardStandard
Dual Element EnclosureShipping
Order HP KW Volts oldFE #
CircuitFuse
Time Delay DimensionsWt. (lbs)
Number # Breaker Fuse W x D x H (in)
CB05411 .5 .37 115 00043 280 104 49 30 A 35 A 20 A 4.8 x 2.9 x 8.4 4
CB05412 .5 .37 230 00044 280 105 49 15 A 20 A 10 A 4.8 x 2.9 x 8.4 4
CB07412 .75 .55 230 00054 280 107 49 20 A 25 A 15 A 4.8 x 2.9 x 8.4 4
CB10412 1 .75 230 00064 280 108 49 25 A 30 A 20 A 4.8 x 2.9 x 8.4 4
7/24/2019 Gould Pumps
4/12
ITT CENTRIPROResidential Water
3
INSTALLING A PumpSaverINSIDER
1. Remove the cover from the front of the 3-wire CentriProcontrol box.
2. Remove the yellow wire from the terminal strip at L2.
3. Remove the black wire from L1 to the capacitor.
4. Press the PumpSaver onto the L1 and L2 terminals.
5. Reconnect the yellow wire to L2 on the PumpSaver.
6. Connect the blue wire attached to the PumpSaver to thedual-lug terminal (with the black wire) of the capacitor.
ORANGE
BLUE
BLK VOLTAGERELAY
1
2
5
YEL
YELRED
B(MAIN) Y(COMM) R(START) L2 L1
MODEL 111/231INSIDER
7/24/2019 Gould Pumps
5/12
ITT
CentriPro and the ITT Engineered Blocks Symbol areregistered trademarks and tradenames of ITT Corporation.
PumpSaver is a registered trademark of SymCom, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
BCQD April, 2008
2008 ITT Corporation
Engineered for life
Residential Water
CentriPro
WIRING DIAGRAM
GND
GREEN
GND
GREEN
BLACK BLACK
START
CAPACITORRELAY
ORANGE
RED
YELLOW
MAIN (B) COMM (Y) START (R) L2 L1
1
2 5
Y
EL.
(MOTOR LEADS) (LINE LEADS)
7/24/2019 Gould Pumps
6/12
4
CentriPro4" Motors and Controls
AGENCY LISTINGS:
Control BoxMay Replace May Replace May Replace
EnclosureShipping
Order HP KW VoltsGP # RJ # FE #
DimensionsWeight (lbs)
Number W x D x H (in)
CB05412CR 0.5 .37 230 NA
50F311CB 2824055015 8.1 x 5.9 x 9.3 7
S50N1CB, A50N1CB
CB07412CR .75 .55 230 NA
75F311CB 2824075015 8.1 x 5.9 x 9.3 7
S75N1CB, A75N1CB
CB10412CR 1 .75 230 NA
S100F311CB 2824085015 8.1 x 5.9 x 9.3 7
S100N1CB, A100N1CB
CB15412CR 1.5 1.1 230 00074
150F311CB282 3008 110 8.1 x 5.9 x 9.3 7
S150N1CB, A150N1CB
CB20412CR 2 1.5 230 00084
200F311CB282 3018 110 8.1 x 5.9 x 9.3 7
S200N1CB, AS200T1CB
CB30412CR 3 2.2 230 00094
300F311CB282 3028 110 8.1 x 5.9 x 9.3 7
S300N1CB
CB50412CR 5 3.7 230 00104
500F311CB282 1138 110 8.1 x 5.9 x 9.3 8
S500N1CB
CSCR (Capacitor Start-Capacitor Run) Control Box Features
Vltage Rela fr installer cnvenience
230 vlt standard mdels 208 vlt rela, rder n. 9K479 is available fr lw vltageapplicatins
Start Capacitrs fr starting trque
Run Capacitrs fr efcienc and quiet peratin
Tpe 3R enclsure fr indr r utdr munting
Accepts up t #2 AWG wire
Multiple knckuts and tw grund terminals
Higher HP mdels require heav dut pressure switches See Magnetic Cntactr versin t use standard pressure switches
Manual reset verlads n 1 5 HP mdels
Note:208 Volt starting relay is available as a repair part for 200-208 volt power supplies, 9K461.
Quick Disconnect Control Box Features
Vltage Relas fr installer cnvenience 115 and 230 vlt mdels
208 vlt rela available fr lw vltage applicatins Start Capacitrs
NEMA 3R enclsure fr indr r utdr munting Multiple knckuts
Quick discnnect cver design will retrt with F.E. Q-D cntrl bxes Tw grund lugs
CentriPro Order Numbers
Control Box
HP KW Volts
Replaces Replaces Enclosure Dimensions Shipping
Order Number old # FE # W x D x H (in) Weight (lbs)
CB05411 .5 .37 115 00043 280 104 49 4.8 x 2.9 x 8.4 4
CB05412 .5 .37 230 00044 280 105 49 4.8 x 2.9 x 8.4 4
CB07412 .75 .55 230 00054 280 107 49 4.8 x 2.9 x 8.4 4
CB10412 1 .75 230 00064 280 108 49 4.8 x 2.9 x 8.4 4
AGENCY
LISTINGS:
UL
C US
ULTESTED To UL AND CSASTANDARDS By UL.
7/24/2019 Gould Pumps
7/12
Residential Water Systems
FEATURES
Voltage Relay for installer convenience230 volt models 208 volt relay, 9K479,
available for low voltage applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quietoperation
Type 3R enclosure for indoor or outdoormounting
Accepts up to #2 AWG wire
Multiple knockouts and two groundterminals
Higher HP models require heavy duty pres-sure switches See Magnetic Contactorversion to use standard pressure switches
Manual reset overloads on 1 5 HPmodels
AGENCY LISTINGS
ITT
CentriProCSCR 1 Control BoxesCapacitor Start - Capacitor Run for3-wire, 5 HP Submersible Motors
CentriPro is a brand of ITT Corporation.
www.centripro.com
Engineered for life
CentriPro
C US
UL TESTED TO UL AND CSA STANDARDS BY UL.
BCCR
7/24/2019 Gould Pumps
8/12
Control Box MayMay Replace May Replace
StandardStandard
Dual Element EnclosureShipping
Order Hp KW Volts ReplaceRJ # FE #
CircuitFuse
Time Delay DimensionsWt. (lbs)
Number GP # Breaker Fuse W x D x H (in)
CB05412CR 0.5 .37 230
50F311CB2824055015 15 20 10 8.1 x 5.9 x 9.3 7
S50N1CB, A50N1CB
CB07412CR .75 .55 230
75F311CB2824075015 20 25 15 8.1 x 5.9 x 9.3 7
S75N1CB, A75N1CB
CB10412CR 1 .75 230
S100F311CB2824085015 25 30 20 8.1 x 5.9 x 9.3 7
S100N1CB, A100N1CB
CB15412CR 1.5 1.1 230 00074
150F311CB282 3008 110 30 35 20 8.1 x 5.9 x 9.3 7
S150N1CB, A150N1CB
CB20412CR 2 1.5 230 00084
200F311CB282 3018 110 25 30 20 8.1 x 5.9 x 9.3 7
S200N1CB, AS200T1CB
CB30412CR 3 2.2 230 00094 300F311CB 282 3028 110 40 45 30 8.1 x 5.9 x 9.3 7 S300N1CB
CB50412CR 5 3.7 230 00104
500F311CB282 1138 110 60 80 45 8.1 x 5.9 x 9.3 8
S500N1CB
ITT
CentriPro is a registered trademark of ITT Corporation. ITT,the Engineered Blocks Symbol and Engineered for Life areRegistered trademarks of ITT Manufacturing Enterprises, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
BCCR January, 2010Copyright (c) 2010 ITT Corporation
Engineered for life
Residential Water Systems
CentriPro
K REPAIR PARTS
Control Box Old Control CapacitorCapacitor Capacitor Capacitor Capacitor
Overload Start Relay Order HP Volts Box Order Repair Part
Mfd. Type Voltage Quantity Order Order
Number Number Number Number Number
CB05412CR .5 230
9K465 43-53 Start 2501 NA 9K458
9K466 15 Run 370
CB07412CR .75 230 9K448 59-71 Start 250
1 N/A 9K458 9K467 23 Run 370
CB10412CR 1 230 9K449 86-103 Start 250
1 N/A 9K458 9K467 23 Run 370
CB15412CR 1.5 230 00074 9K447 105-126 Start 250
1 9K471 9K458 9K452 10 Run 370
CB20412CR 2 230 00084 9K447 105-126 Start 250
1 9K481 9K458 9K451 20 Run 370
CB30412CR 3 230 00094 9K453 208-250 Start 250
1 9K4829K454 45 Run 370
9K459
CB50412CR 5 230 00104 9K455 270-324 Start 330 1
9K4839K456 40 Run 370 2
New 1 HP CSCR control box is now in a larger enclosure, it is notin a quick disconnect style enclosure.
Overloads for 2, 3 and 5 HP CSCR boxes are sold prewired andsoldered as an assembly. No field soldering or wiring required.
If supply voltage is between 200 V 210 V a 208 V start relay,order no. 9K479, is required.
7/24/2019 Gould Pumps
9/12
5
Features
Built-in Magnetic Contactors allow the use ofstandard pressure switches, prolong switchlife and eliminate the need to source andinstall separate contactors, saving installationtime and reducing total system componentcosts.
Voltage Relay for installer convenience
230 volt standard models 208 volt relay,order no. 9K479 is available for low voltageapplications
Start Capacitors for starting torque
Run Capacitors for efciency and quietoperation
Type 3R enclosure for indoor or outdoormounting
Accepts up to #2 AWG wire
Multiple knockouts and two groundterminals
Manual reset overloads on 1 5 HPmodels
AGENCY LISTINGS:
MAGNETIC CONTACTOR 1 CONTROL BOXESFor 3-wire, 1 5 HP Submersible Motors
C US
UL TESTED To UL AND CSA STANDARDS By UL.
1 3 HP
7/24/2019 Gould Pumps
10/12
Residential Water Systems
FEATURES
Built-in Magnetic Contactors allow the use
of standard pressure switches, prolongswitch life and eliminate the need to sourceand install separate contactors, savinginstallation time and reducing total systemcomponent costs.
Voltage Relay for installer convenience
230 volt standard models 208 volt relay,9K479 available for low voltage applications
Start Capacitors for starting torque
Run Capacitors for efficiency and quietoperation
Type 3R enclosure for indoor or outdoormounting
Accepts up to #2 AWG wire
Multiple knockouts and two groundterminals
Manual reset overloads on 1 5 HPmodels
AGENCY LISTINGS
ITT
CentriProMagnetic Contactor 1 Control BoxesFor 3-wire, 1 5 HP Submersible Motors
CentriPro is a brand of ITT Corporation.
www.centripro.com
Engineered for life
CentriPro
C US
UL TESTED TO UL AND CSA STANDARDS BY UL.
1 3 HP
5 HP is in larger enclosure
BCMC
7/24/2019 Gould Pumps
11/12
ITT
CentriPro is a registered trademark of ITT Corporation. ITT,the Engineered Blocks Symbol and Engineered for Life areRegistered trademarks of ITT Manufacturing Enterprises, Inc.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
BCMC January, 2010Copyright (c) 2010 ITT Corporation
Engineered for life
Residential Water Systems
CentriPro
MAGNETIC CONTACTOR (MC) CONTROL BOXES FOR 3 WIRE, 1,
4" CENTRIPRO MOTORS AND 4" (6", 5 HP) FRANKLIN ELECTRIC MOTORS
Control Box
Replaces Replaces Replaces
StandardStandard
Dual Element EnclosureShipping
Order Number
HP KW VoltsGP # RJ # FE #
CircuitFuse
Time Delay DimensionsWt. (lbs)
Breaker Fuse W x D x H (in)
CB15412MC 1.5 1.1 230 No Equal No Equal No Equal 30 35 20
CB20412MC 2 1.5 230 00084MC No Equal 2823018310 25 30 20 8.1 x 5.9 x 9.3 8
CB30412MC 3 2.2 230 00094MC S300N1CBC 2823028310 40 45 30
CB50412MC 5 3.7 230 00104MC S500N1CBC 2821139310 60 80 45 11 x 6.7 x 12.5 15
"K" REPAIR PARTS FOR MAGNETIC CONTACTOR "MC" CONTROL BOXES
Control Box
CapacitorCapacitor Capacitor Capacitor Capacitor
Contactor Overload Start Relay
Order Number HP KW Volts Repair Part
Type Mfd. Voltage Quantity Order Order Order
Number Number Number Number
CB15412MC 1.5 1.1
9K447 Start 105-126 2509K493
9K452 Run 10 370
CB20412MC 2 1.5 9K447 Start 105-126 250
1
9K485 9K480 (S)
9K458
230 9K451 Run 20 370 9K472 (M)
CB30412MC 3 2.2 9K453 Start 208-250 250 9K473 (S)
9K454 Run 45 370 9K474 (M)
CB50412MC 5 3.7 9K455 Start 270-324 330 1 9K486 9K475 (S) 9K459 9K456 Run 40 370 2 9K476 (M)
Repair parts above are compatible with and replace parts in old Goulds Pumps or Franklin Electric control boxes.
If supply voltage is between 200 V 210 V a 208 V start relay, order no. 9K479, is required.
7/24/2019 Gould Pumps
12/12
7
BALANCED FLOW
BF20, BF30 and BF50Constant Pressure Controllers for -2, 3 and 5 HP Submersible Pumps
Features
Enclosure Rating: NEMA 3R, IP22 rainproof,indoor/outdoor enclosure. Allows mountingthe controller outdoors.
Current Limit Selector Switch: Rotary switchto set current limit to match motor ServiceFactor Amps (SFA).
The controller may be used on smallerpump/motor combinations as long as themotor SFA is within the current limit rangeof the controller.
Communications Port: RS-232 serial portto facilitate software updates and futureexpansion.
Three sizes available for - 5 HP pumps.
Constant Pressure: The system providesconsistent pressure even as system owrequirements vary.
Controller acts as a pump protection deviceand troubleshooting device.
Flashing LED lights indicate system faults bynumber of ashes.
Controller will operate between 190 and260 volts.
Includes a pressure sensor and sensor cable.
Integrated output motor lter protectsthe motor from voltage spikes and limitselectrical interference with devices such asportable telephones, radios, televisions andgarage door openers.
Cooling fan: Allows operation in ambienttemperatures up to 122F.
Top Related