revision: A - WIPdrawing number: A0.01project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCECOVER
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
DWG INDEX
DWG #A0.01
A1.01
A2.01
A2.02
A2.03
A2.04
A2.05
A2.06
A2.07
A2.08
A3.01
A3.02
A3.03
A3.04
A3.05
A3.06
A3.07
A3.08
A3.09
A4.01
A4.02
A4.03
A4.04
A4.05
A4.06
A4.07
A4.08
A4.09
A4.10
A4.11
DRAWING NAMECOVER
SITE PLAN
DEMOLITION GROUND FLOOR PLAN
DEMOLITION FIRST FLOOR PLAN
PROPOSED SLAB SETOUT PLAN
PROPOSED GROUND FLOOR PLAN
PROPOSED FIRST FLOOR PLAN
PROPOSED ROOF PLAN
PROPOSED GROUND FLOOR RCP
PROPOSED FIRST FLOOR RCP
NORTH ELEVATION
SOUTH ELEVATION
EAST ELEVATION
WEST ELEVATION
SECTIONS
SECTIONS
SECTIONS
SECTIONS
STAIR DETAILS
INTERNAL ELEVATIONS - RUMPUS/GUEST
INTERNAL ELEVATIONS - GARAGE
INTERNAL ELEVATIONS - GARAGE
INTERNAL ELEVATIONS - GROUND FLOO...
INTERNAL ELEVATIONS - KITCHEN
INTERNAL ELEVATIONS - PLAY ROOM
INTERNAL ELEVATIONS - LIVING & BEDR...
INTERNAL ELEVATIONS - BEDROOM 1
INTERNAL ELEVATIONS - BEDROOM 2
INTERNAL ELEVATIONS - BEDROOM 3
INTERNAL ELEVATIONS - 1ST FLOOR BA...
REVA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Proposed Perspective
0mm 4000 8000 20000
SCALE 1:400 @ A32-
Existing Perspective
0mm 4000 8000 20000
SCALE 1:400 @ A31-
GEORGE ST RESIDENCE78 George Street, Mackay, QLD, 4740
revision: A - WIPdrawing number: A1.01project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCESITE PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
WG04
WG10WG
07WG09
WG08
WG06WG
05DG02
WG01
DG03
DG04
DG01
40.2
34m
,0°
0' 0
"
20.117m,90° 0' 0"
40.2
34m
,18
0° 0
' 0"
20.117m,270° 0' 0"
DG10
WG02
WG03
DG09
Lot 54RP702028
G E O R G E S T R E E T
55RP702028
53RP702028
1
RL 7.04
3
RL 7.04
2
RL 7.03
3
RL 7.02
0
RL 6.87
1
RL 6.88
6
RL 7.01
2
RL 7.01
6
RL 7.00
3
RL 6.88
9RL 6
.856
RL 7.01
3
RL 7.00
5
RL 7.03
0
RL 7.07
8
RL 7.13
1
RL 7.23
5
RL 7.21
2
RL 7.19
4
RL 7.22
1
RL 7.23
6
RL 7.24
1
RL 7.17
6
RL 7.13
1
RL 7.11
6
RL 7.06
4
RL 7.10
8
RL 7.18
7RL 7
.217
RL 7.31
5 7.210
RL 7.30
8
RL 7.30
8
RL 7.18
8
RL 7.07
9
RL 7.14
8
RL 7.12
5RL 7
.104
RL 7.13
6
RL 7.17
7RL 7
.191
RL 7.15
0
RL 7.12
5
RL 7.03
8
RL 7.59
4
RL 7.01
3
RL 7.03
1RL 7
.105
RL 7.17
8
RL 7.16
6
RL 7.13
1
RL 7.17
2
RL 7.16
5
RL 7.16
6
RL 7.13
3
RL 7.15
5
RL 7.15
7RL 7.13
2RL 7.44
1
RL 7.03
9
RL 7.03
7
RL 7.03
7
RL 7.03
0
RL 7.02
0
RL 7.72
4
RL 7.72
4
RL 8.73
8
RL 7.02
7
RL 7.02
2
RL 7.06
9
RL 7.11
7
RL 7.11
1
RL 7.04
1
RL 7.11
6
RL 7.08
3
RL 7.16
0RL 7.17
7
RL 7.17
4
RL 7.18
9
RL 7.22
7
RL 7.23
1
RL 7.01
1
RL 7.09
8
RL 7.05
6
RL 6.85
3
RL 6.85
4RL 7
.001
WM
ELEC
New exposed aggregatedriveway
EXISTINGPOOL & DECK
TURFED AREA
Existing tree to remain
New gate
Approximatelocation ofexisting sewer
Exist
ing co
ncre
te pa
th
Existing treeto remain
Existing treeto remain
Additional 10.9m²enclosed floor areaon First Floorshown dashed
RL 7.00
6
RL 7.22
5
NEWENCLOSEDGROUNDFLOOR7,810 A.H.D.
GARAGE
RUMPUS /GUEST
BATHROOM
LAUNDRY
UNDERCROFT
40.2
34m
,0°
0' 0
"
20.117m,90° 0' 0"
40.2
34m
,18
0° 0
' 0"
20.117m,270° 0' 0"
Lot 54RP702028
G E O R G E S T R E E T
55RP702028
53RP702028
1
RL 7.04
3
RL 7.04
2
RL 7.03
3
RL 7.02
0
RL 6.87
1
RL 6.88
6
RL 7.01
2
RL 7.01
6
RL 7.00
3
RL 6.88
9RL 6
.856
RL 7.01
3
RL 7.00
5
RL 7.03
0
RL 7.07
8
RL 7.05
3RL 7
.104
RL 7.13
1
RL 7.23
5
RL 7.21
2
RL 7.16
5
RL 7.19
4
RL 7.21
7
RL 7.22
1
RL 7.23
6
RL 7.24
6
RL 7.24
1
RL 7.17
6
RL 7.13
1
RL 7.11
6
RL 7.06
4
RL 7.10
8
RL 7.18
7RL 7
.217
RL 7.31
5 7.210
RL 7.13
3
RL 7.23
4RL 7
.308
RL 7.30
8
RL 7.78
3
RL 7.80
8
RL 7.16
4
RL 7.26
8RL 7.17
7
RL 7.22
4
RL 7.18
8
RL 7.07
9RL 7.09
0
RL 7.14
8RL 7
.123
RL 7.12
5RL 7
.104
RL 7.13
6
RL 7.17
7
RL 7.15
6RL 7
.191
RL 7.15
0
RL 7.12
5
RL 7.03
8
RL 7.59
4
RL 7.01
3
RL 7.03
1RL 7
.105
RL 7.17
8
RL 7.16
6
RL 7.13
1
RL 7.14
9
RL 7.17
2
RL 7.16
5
RL 7.16
6
RL 7.13
3
RL 7.15
5
RL 7.15
7RL 7.13
2RL 7.44
1
RL 7.03
9
RL 7.03
7
RL 7.03
7
RL 7.03
0
RL 7.02
0
RL 7.72
4
RL 7.72
4
RL 8.73
8
RL 7.02
7
RL 7.02
2
RL 7.06
9
RL 7.11
7
RL 7.11
1
RL 7.04
1
RL 7.11
6
RL 7.08
3
RL 7.16
0RL 7.17
7
RL 7.17
4
RL 7.18
9
RL 7.22
7
RL 7.23
1
RL 7.01
1
RL 7.09
8
RL 7.05
6
RL 6.85
3
RL 6.85
4RL 7
.001
WM
ELEC
UNDERCROFT
EXISTINGPOOL & DECK
TURFED AREA
Existing tree to remain
Approximatelocation ofexisting sewer
Exist
ing co
ncre
te pa
th
Exist
ing co
ncre
te pa
th
Existing treeto remain
Existing treeto remain
Additional 10.9m²enclosed floor areaon First Floorshown dashed
RL 7.00
6
RL 7.22
5
EXISTINGUNDERCROFT7,200 A.H.D. Approx.
GUEST
BATH
LDRY
STORE
GARAGE
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundary
SITE PLAN PROPOSED
0mm 2000 4000 10000
SCALE 1:200 @ A3
Project North
SITE PLAN EXISTING
0mm 2000 4000 10000
SCALE 1:200 @ A3
Project North
revision: A - WIPdrawing number: A2.01project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEDEMOLITION GROUND FLOOR PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundaryWall to be demolishedExisting wallNew wall
Remove existing stone& brick walls
Remove existing walls& doors shown dashed
Remove existing columnsthroughout ground floor. Tobe replaced with steelcolumns. Refer toStructural Eng. drawings &details for sizing &connection details
Remove existing bathroomfixtures & cap off drainage
Remove existingconcrete slabs toundercroft area
T.B.C.
Remove & salvageexisting timber batteninfill panels
Existing timber stairs &balustrade to be lifted tosuit new first floor height
Remove existing carport,including roller door &associated columns
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg. Col. Extg.Col. Extg.
Col.
Extg.Col.
Extg.Col.
Existing timber battenarchway infill panels tobe retained & re-used
Remove existingcolumns, stud infills &timber batten archwayinfill panels
Existing timber stairs &balustrade to remain
Existing timber battenfence & gate to be removed
Remove existing concreteslabs. Confirm extent to beremoved on site
Exist
ing la
ndsc
aping
to re
main
Existing turf
Existing turf
Exist
ing la
ndsc
aping
to re
main
ExtgGas
55RP702028
53RP702028
Existing concreteslab to be removed
Remove & salvage existingtimber batten infill panels
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
Relocate existing fence &gate. Refer to A2.04 fornew location
Remove existing hotwater system
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.Extg.Col.
Extg.Col.
Extg.Col.Extg.
Col.Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Existing concretepath to remain
Existing
concr
ete
path to
remain
Remove all existingconcrete paths
Remove section ofconcrete path
Protect extg NBNbox & reinstate
Remove existing concrete
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1DEMOLITION GROUND FLOOR
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
revision: A - WIPdrawing number: A2.02project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEDEMOLITION FIRST FLOOR PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundaryWall to be demolishedExisting wallNew wall
Remove existing walls& doors shown dashed
Existing timber stairs &balustrade to remain.Raise to match newlevel of building
Remove existing toilet.Remove redundant drainagelines as required.Remove existing floorboardsto this area
Existing timber deck &roof to remain. Removebox gutter betweendeck roof & house roof
Existing Kitchen joineryto be removed
Existing bathroom walls,joinery & fixtures to beremoved
Existing wardrobe tobe removed
Existing timber stairs &balustrade to be lifted withthe rest of the house
Remove existing carport,including roller shutter &associated columns
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
Line o
f roo
f ove
r
Line o
f roo
f ove
r
Line of roof over
Line of roof over
Line of roof over
Retain existing sunhood
Existing sunhoodsto be removed
Retain existing sunhood
Retain existing sunhood
Existing timber framedexternal wall removed. Referto sections & elevations forextent of removal. Salvagewindows. All existingweatherboards removed areto be salvaged for re-use inthe project if viable
Remove existing door
Existing bathroom doorto be removed and re-used for new bathroom
Existing doors to bere-hung to opentowards bedroom
All carpet throughout to beremoved
All carpet throughout to beremoved
Remove existing walllining to reveal T&Gboarding behind
Existing hinged door tobe removed and re-used as front entry door
Remove & salvage existinghinged door
Existing walls removedto hight of 2100 A.F.L.
Section of wall above 2100 tobe retained & modified. Referto bedroom internalelevations & seek advice fromstructural engineer.
Section of floor to beremoved for new stairs
Remove sections ofexisting wall. Refer to1/A4.07 for extentRemove sections ofexisting wall. Refer to5/A4.06 for extent
Modify existing casementwindow to accomodate newinternal stud wall to Bathroom
Removeextg A/C Remove
extg A/C
Removeextg A/C
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1DEMOLITION FIRST FLOOR
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
revision: A - WIPdrawing number: A2.03project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED SLAB SETOUT PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
1,265 3,375 3,625 4,040
12,305
2,250
1,200
300
300 50
5
2,600
1,140
2,225
1,200
60030
030
01,1
05
4,000 600 1,820 1,180
7,810
7,810
7,785
7785
77857,785 7,785
7,260
7,167
7,263
7,200
-592
7,220
7,152
7,332
7,106
7,630
7,7607,610 7,460
7,310
7,760
1A2.03
5A2.03
55RP702028
53RP702028
col.col. col. col. col. col. col.
col.
col.
col.
col.
col.col.
col.col.
col.
col.
col.
col.
col. col.
col.
col.
col.
col.
col.
col. col.col.
col.
col.col.
col.
col.
col.
col. col. col.
col.col.
50
50
50
Step
FALL
Max.
1:4
FALLExisting concrete path
Polished concrete to areashown hatched (bathroom& rumpus).
Stairsup
Stairsup
Refer to structural engineersdrawings and details for more info onsteel columns & conrete slab.
DRIVEWAYExposed Aggregate
Step
New concrete pathto finish flush withexisting concrete
FALL
New exposedaggregate concretedriveway. Providemax. 1:4 grade fromnatural ground levelto internal floorlevel. Provide gradetransitions toprevent vehiclescrapage
Gard
en B
ed
GardenBed
FALL
Max.
1:8FA
LLMa
x. 1:8
FALL
Line of footing under shown dashed
Provide setdown in concrete slab fornew aluminium framed sliding doorthreshold track
Existing concretepath to remain
Existing
concr
ete
path to
remain
400 x 400 concrete blockplinths to base of existingtimber columns
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg. Col. Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
NewCol.
Extg.Col.
Extg.Col.
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1
7,810 7,810
7,810
4A2.03
2A2.03
3A2.03
190620 190 1,033 190 420 190
Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details
R.L. 7,810
R.L. 8,160
R.L. 7,220
R.L. 7,785
R.L. 8,160
R.L. 7,220
190 2,110 190 1,843 190 420
Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details
R.L. 7,785
R.L. 8,160
Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details
R.L. 7,785
Concrete slabRefer to Structural Eng. details
Timber stud wall
External cladding
Sub-floor wallsRefer to Structural Eng. details
Natural ground level
Compacted fill
Footings shown indicative only.Refer to Structural Eng. drawingsfor details
SLAB SETOUT PLAN
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
SECTION S1
0mm 500 1000 2500
SCALE 1:50 @ A31-
SECTION S3
0mm 500 1000 2500
SCALE 1:50 @ A33-
SECTION S2
0mm 500 1000 2500
SCALE 1:50 @ A32-
SECTION S4
0mm 500 1000 2500
SCALE 1:50 @ A34-
STANDARD SLAB EDGE
0mm 200 400 1000
SCALE 1:20 @ A35-
revision: A - WIPdrawing number: A2.04project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED GROUND FLOOR PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundaryWall to be demolishedExisting wallNew wall
WG04
WG10
WG07
WG09
WG08
WG06
WG05
DG02
WG01
DG03
DG04
DG01
F WM CD
01020304050607080910111213
DG05
DG06
DG07
DG08
DG10
WG02
WG03
DG09
N
E
W
1A3.08
1A3.08
1A3.07
1A3.07
1A3.05
1A3.05
1A3.06
1A3.06
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg. Col. Extg.Col. Extg.
Col.
Extg.Col.
Extg.Col.
Exist
ing la
ndsc
aping
to re
main
Existing turf
Existing turf
Exist
ing la
ndsc
aping
to re
main
EXISTINGUNDERCROFT
STORAGE
RUMPUS / GUEST
BATHROOM
UNDERCROFT
GARAGE
ExtgGas
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.New
Col.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
LAUNDRY
Cup'd under stair
55RP702028
53RP702028
RL 7.23
5
RL 7.21
2
RL 7.19
4
RL 7.22
1
RL 7.23
6
RL 7.24
1
RL 7.17
6
RL 7.13
1
RL 7.21
7
RL 7.31
5
7.210
RL 7.30
8
RL 7.18
8
RL 7.14
8
RL 7.12
5
RL 7.10
4RL 7
.136
RL 7.17
7
RL 7.19
1RL 7
.150
RL 7.12
5
RL 7.03
8
RL 7.17
8
RL 7.16
6
RL 7.13
1
RL 7.17
2
RL 7.16
5
RL 7.16
6
RL 7.13
3
RL 7.15
5
RL 7.15
7
RL 7.03
7
RL 7.02
7
RL 7.06
9
RL 7.11
7
RL 7.11
1
RL 7.11
6
RL 7.08
3
RL 7.16
0
RL 7.17
4RL 7
.231
DRIVEWAY
Concrete
Concrete
NewCol.
Extg.Col.
NewCol.
Polished Concrete
Polished Concrete
Concrete
Exposed Aggregate
New concrete stairtreads at base ofexisting timber stairs
New timber fence &gate
NewCol.
NewCol. New
Col.
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
R.L. 7810
MSBDB
New timberfence & gate
Ground floor to beenclosed. Internalpartitons to be removedas per demolition plan
Column faces to grid
R.L. 7810
R.L. 7810
R.L. 7810
ConcreteR.L. 7785
Existing Concrete
Existing concretepath to remain
Existing
concr
ete
path to
remain
New concrete plinths toprovide fixing points forexisting raised columns.Approx. 600 high -confirm on site
Extg.Col.
NewCol. Work bench, open under.
Constructed from recycledhardwood palings fromhouseNew
Col.NewCol.
NewCol.
Location of futureA/C/ condenser.Allow power
Full h
t cup
d's
Open
shelv
ing
Refer to internalelevations for joinerydetails
Refer to internalelevations for joinerydetails
90
90
90
90
90
90
90
90
90
90909090
90 90
90
909090
90
90
90
9090
90
Reinstate extg NBNbox. Location TBC
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1
NewCol.
RL 7.00
6
RL 7.22
5
W000
D000
LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp
Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr
Column - Refer to Structural Engineer's documentation.col.
Floor Waste Gate - Fall tiles into floor waste.fwg
New Door Number - Refer to Door Schedule
New Window Number - Refer to Window Schedule
90
Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.
70
Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.
Refer to internal & external elevations for all walllinings & external claddings.
DOOR SCHEDULE - GROUND FLOORAll dimensions to be confirmed on site prior to manufacture.Door No. Description
DG.01
DG.02
DG.03, 04
DG.05
DG.06
DG.07
DG.08
DG.09, 10
2200 x 2700 B&D roller door (or equal approved) with motor& remote. Colour to be confirmed.
2165 x 1730 Aluminium framed sliding glass door, XO
2175 x 900 (size to be confirmed) face sliding timber door.Paint finish. Provide 'Brio' Open Square Rail sliding system.
2100 x 2400 Custom made, double sliding door. Provide 50 x50 aluminium frame, clad externally with 'Ampelite' WebglassGC 5 rib profile, Opal colour. Provide 'Brio' Single Run 180sliding system.
2100 x 1200 (similar to DG.04)
2100 x 1000 (similar to DG.04)
2100 x 950 (size to be confirmed) custom made hinged door.Provide 50 x 50 aluminium frame, clad externally with'Ampelite' Webglass GC 5 rib profile, Opal colour.
2040 x 80 Cavity sliding door. Paint finish
WINDOW SCHEDULE - GROUND FLOORAll dimensions to be confirmed on site prior to manufacture.Window No. Description
WG.01
WG.02
WG.03
WG.04
WG.05, 06, 07
WG.08, 09, 10
1200 x 1475 Aluminium framed sliding glass window, XO900 sill, 2100 head. Grey tint glass.
900 x 1120 Aluminium framed sliding glass window, XO1200 sill, 2100 head. Frosted glass.
1600 x 600 Aluminium framed fixed glass window0 sill, 1600 head. Grey tint glass.
1600 x 450 Aluminium framed fixed glass window0 sill, 1600 head. Grey tint glass.
555 x 405 Aluminium framed louvre window0 sill, 555 head. Grey tint glass.
555 x 510 Aluminium framed louvre window0 sill, 555 head. Grey tint glass.PROPOSED GROUND FLOOR
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
NOTE - WALL LININGS & STUDSRefer to room elevations for extent of wall linings.Essentially all external & internal walls except whereshown (Bathroom, Laundry & parts of Rumpus) are to beun-lined & studs are to be exposed.All new studs are to be seasoned hardwood and will beleft unfinished.Noggings are to be in line (not staggered) and whereshown on internal elevations.
revision: A - WIPdrawing number: A2.05project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED FIRST FLOOR PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundaryWall to be demolishedExisting wallNew wall
FDW
W109
W108
D102
W107 D1
01
D103 D1
04
W104
W106
W105
W103 W1
02W101
D105
N
E
W
1A3.08
1A3.08
1A3.07
1A3.07
1A3.05
1A3.05
1A3.06
1A3.06
100
1,110
90
KITCHEN
DINING
DECK
LIVING
BATHROOM
BEDROOM 1
BEDROOM 2 BEDROOM 3
STUDY
PLAY ROOM
Col.
Col.
Col.
Col.
Col. Col. Col.
Col.
Col.
Robe
Full ht cupd'sWC
ExtgTimber
New Carpet
New Carpet
New CarpetNew Carpet
New Carpet
Re-use existingcasement windows
Re-use existing casementwindow. New timber framed,fixed glass windows adjacent
Extg Timber
Extg Timber
Extg Timber
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
Line o
f roo
f ove
r
Line o
f roo
f ove
r
Line of roof over
Line of roof over
Full h
t cup
d's
Built-in bedDrawers under
Bench open underMobilebench
Bench open under
Full ht cupd's
Full ht cupd's
Drawer
Drawer
Benc
h cup
bd's
unde
r
Full htcupd
Full h
t cup
d's
Bench cupbd's under
Refer to internalelevations for joinerydetails
Refer to internalelevations for joinerydetails
Refer to internalelevations for joinerydetails
extg door
extg
wind
owex
tgwi
ndow
extg
wind
ow
extg window
extg window
extg window
extg
wind
ow
extg
wind
ow
extg
wind
ow
extg door
extg door
extg door
extg door extg door
extg
door
ExtgCol.
ExtgCol.
ExtgCol.
ExtgCol.
ExtgCol.ExtgCol.
ExtgCol.
New balustrade
Robe
Extg Timber
70
70
90
9090
90
90
90
9090
90
70
70
70
70
New aluminium screen
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1
W000
D000
LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp
Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr
Column - Refer to Structural Engineer's documentation.col.
Floor Waste Gate - Fall tiles into floor waste.fwg
New Door Number - Refer to Door Schedule
New Window Number - Refer to Window Schedule
90
Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.
70
Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.
Refer to internal & external elevations for all walllinings & external claddings.
DOOR SCHEDULE - FIRST FLOORAll dimensions to be confirmed on site prior to manufacture.Door No. Description
D1.01
D1.02
D1.03
D1.04
D1.05
Existing door relocated from Kitchen. Modify existing openingto suit.
2100 x 1350 Timber framed hinged glass door with sidelight.Grey tint glass.
Existing hinged double door, re-hung in same location toswing inward towards Bedroom 1.
2040 x 720 hinged door. Paint finish.
Existing hinged door relocated from existing Bathroom.
WINDOW SCHEDULE - FIRST FLOORAll dimensions to be confirmed on site prior to manufacture.Window No. Description
W1.01
W1.02
W1.03
W1.04
W1.05
W1.06
W1.07
W1.08
W1.09
Existing window relocated.
Existing window relocated.
1000 x 600 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.
1000 x 570 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.
Existing window relocated.
1000 x 570 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.
450 x 600 (Size to be confirmed) aluminium framed fixedwindow where A/C unit removed. Grey tint glass.
1125 x 470 Timber framed window. Modify existingcasement window.
1125 x 1395 Timber framed window. Modify existingcasement window.PROPOSED FIRST FLOOR
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
NOTE - WALL LININGS & STUDSRefer to room elevations for extent of wall linings.Essentially all external & internal walls except whereshown (Bathroom, Laundry & parts of Rumpus) are to beun-lined & studs are to be exposed.All new studs are to be seasoned hardwood and will beleft unfinished.Noggings are to be in line (not staggered) and whereshown on internal elevations.
revision: A - WIPdrawing number: A2.06project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED ROOF PLAN
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
RL 2,000
GENERAL NOTES
DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.
RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.
Existing RL
New RL+ R
L 7.40
0
EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.
Site boundaryWall to be demolishedExisting wallNew wall
N
E
W
1A3.08
1A3.08
1A3.07
1A3.07
1A3.05
1A3.05
1A3.06
1A3.06
Patch existing Deck roofand House roof wherebox gutter removed
Line of building under
New section of roof overfirst floor extension
Existing house roof
Existing Deck roof
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1
Line of building under
Line of building under
Line of building under
Line o
f buil
ding u
nder
W000
D000
LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp
Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr
Column - Refer to Structural Engineer's documentation.col.
Floor Waste Gate - Fall tiles into floor waste.fwg
New Door Number - Refer to Door Schedule
New Window Number - Refer to Window Schedule
90
Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.
70
Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.
Refer to internal & external elevations for all walllinings & external claddings.
ROOF PROPOSED
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
revision: A - WIPdrawing number: A2.07project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED GROUND FLOOR RCP
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg.Col.
Extg. Col. Extg.Col. Extg.
Col.
Extg.Col.
Extg.Col.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
NewCol.
Cup'd under stair
NewCol.
Extg.Col.
NewCol.
NewCol.
NewCol. New
Col.
Extg.Col.
NewCol.
NewCol.
NewCol.
NewCol.
New FC ceilingCH 2285
Paint finish
New grooved ply ceilingCH 2410
Paint finishNewfan
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1
NewCol.
PROPOSED GROUND FLOOR RCP
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
NOTE - LIGHTINGAll new & existing lighting to be discussed & confirmed onsite unless noted specifically on drawings.
revision: A - WIPdrawing number: A2.08project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEPROPOSED FIRST FLOOR RCP
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
Repair rotten timber inexisting soffit
Col.
Col.
Col.
Col.
Col. Col. Col.
Col.
Col.
extg door
extg
wind
owex
tgwi
ndow
extg
wind
ow
extg window
extg window
extg window
extg
wind
ow
extg
wind
ow
extg
wind
ow
extg door
extg door
extg door
extg door extg door
extg
door
ExtgCol.
ExtgCol.
ExtgCol.
ExtgCol.
ExtgCol.ExtgCol.
ExtgCol.
New plasterboard ceilingCH 2300Paint finish
New plasterboard ceilingOn rakePaint finish
Extg ceilingExtg ceiling
Extg ceiling
Extg ceiling
Extg rakedceilingExtg ceiling
Extg ceiling
Extg soffit
New mezzanine floorNew high level rakedplasterboard ceiling.Paint finishExtg raked
ceiling
Extg rakedceiling
Extg rakedceiling
Extg soffit
A A
B B
C C
D D
E E
F F
5
5
4
4
3
3
2
2
1
1PROPOSED FIRST FLOOR RCP
0mm 1000 2000 5000
SCALE 1:100 @ A3
Project North
NOTE - LIGHTINGAll new & existing lighting to be discussed & confirmed onsite unless noted specifically on drawings.
revision: A - WIPdrawing number: A3.01project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCENORTH ELEVATION
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
DG05 06
DG07DG
WG01
W105
W106
W104W1
01W102
EXDP
EXDP EXDP
EXDP
DP
DP
DPDP
DP
Boun
dary
Boun
dary
Sliding doorsRefer to schedule
Flashing to Ampelite /Weatherboard junction
Proposed Ground Floor Lvl 0 (R.L. 7.810)
Proposed First Floor Lvl 2,600 (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
EC01
EC01EC01
EC01
EC02
EC02 EC02
CB01 CB01 CB01CB01
ECEXECEX ECEX
EXDP
EXVP
EXDP
EXDP
EXDP
EXDP
EXVP
Boun
dary
Boun
dary
Remove existing timberpaling infill panels.Salvage for re-use
Remove existing columnsthroughout ground floor -refer to Proposed Plan forlocations of new columns
Existing timber stairs &balustrade to be raised
Existing timber battenfence & gate to remain
Existing timber framed externalwall & associated windows &doors to be removed
Existing timber deck & deckroof to be raised. Remove boxgutter between deck roof &house roof
Proposed Ground Floor Lvl (R.L. 7.810)
Proposed First Floor Lvl (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)
ECEX
EC01
EC02
CB01
GP
DP
NORTH ELEVATION PROPOSED
0mm 1000 2000 5000
SCALE 1:100 @ A32-
NORTH ELEVATION EXISTING
0mm 1000 2000 5000
SCALE 1:100 @ A31-
revision: A - WIPdrawing number: A3.02project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCESOUTH ELEVATION
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
DG02
DG01
WG10
WG07
WG04
WG02
WG09
WG08
WG06
WG05
D101
EXDP
EXDP
EXDP
EXDP
Boun
dary
Boun
dary
CB01 CB01CB01
Flashing to Ampelite /Weatherboard junction
New location ofexisting door
New roller door.Refer to schedule
New aluminium screen
Proposed Ground Floor Lvl 0 (R.L. 7.810)
Proposed First Floor Lvl 2,600 (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
ECEX ECEX
ECEX ECEX ECEX
EC01
EC01
EC02
ECEX
ECEX
EXDP
EXDPEXDP
EXDP
EXVP
Boun
dary
Boun
dary
Existing timber stairs &balustrade to be relocated tosuit new first floor height
Remove existing carport,including roller shutter &associated columns
Remove existingcolumns, stud infills &timber batten archwayinfill panels
Existing timber battenfence & gate to remain
Remove existing timber palinginfill panels. Salvage for re-useRemove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns
Proposed Ground Floor Lvl (R.L. 7.810)
Proposed First Floor Lvl (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)
ECEX
EC01
EC02
CB01
GP
DP
SOUTH ELEVATION PROPOSED
0mm 1000 2000 5000
SCALE 1:100 @ A32-
SOUTH ELEVATION EXISTING
0mm 1000 2000 5000
SCALE 1:100 @ A31-
revision: A - WIPdrawing number: A3.03project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEEAST ELEVATION
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
W103W1
08W109
EXDP
EXDPDP
DP DP
DP
Flashing to Ampelite /Weatherboard junction
New aluminium screen
Proposed Ground Floor Lvl 0 (R.L. 7.810)
Proposed First Floor Lvl 2,600 (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
ECEXEC01
EC02
ECEXEC01
EC02
ECEX
CB01 CB01
EXDP EXDP
EXVP
EXVP
EXDP
EXDPEXDPEXVP
Existing timber stairs &balustrade to be relocated tosuit new first floor heightRemove existing carport,including roller shutter &associated columns
Remove existing timber palinginfill panels. Salvage for re-use
Remove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns
Remove existing timber paling infillpanels. Salvage for re-use
Existing timber framed externalwall & associated windows &doors to be removed
Existing timber deck & deckroof to be raised
Remove box gutter betweendeck roof & house roofExisting timber framed externalwall & associated windows &doors to be removed
Remove existing A/C unit& infill wall
Remove existing A/C unit& replace with new
Modify existing casementwindow to accomodate newbathroom layout
Remove existing vent pipes
Remove existingdownpipe
Remove existing vent pipe
Proposed Ground Floor Lvl (R.L. 7.810)
Proposed First Floor Lvl (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)
ECEX
EC01
EC02
CB01
GP
DP
EAST ELEVATION PROPOSED
0mm 1000 2000 5000
SCALE 1:100 @ A32-
EAST ELEVATION EXISTING
0mm 1000 2000 5000
SCALE 1:100 @ A31-
revision: A - WIPdrawing number: A3.04project number:PENDING
date: 29/05/2015
F O R A P P R O V A L
GEORGE ST RESIDENCEWEST ELEVATION
78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50
08DG
WG03
D102EXDP EXDP
EXDP
EXDP
EXDPDP W107
Flashing to Ampelite /Weatherboard junction
New window where A/Cunit removed
Future A/C unit. Allow power
Reinstate extg NBN box.Location TBC
Proposed Ground Floor Lvl 0 (R.L. 7.810)
Proposed First Floor Lvl 2,600 (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
ECEX
EC02
CB01
ECEX
ECEX
ECEX ECEX
ECEX
EC01 EC01
CB01 CB01
ECEX
EXVP
EXDPEXDP
EXDPEXDP
EXDPEXDP
Existing timber battenfence & gate to remain
Existing timber stairs &balustrade to be raised
Existing timber stairs &balustrade to be relocated tosuit new first floor heightRemove existing carport,including roller shutter &associated columns
Remove existing timber palinginfill panels. Salvage for re-use
Remove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns
Existing timber deck & deckroof to be raised
Remove box gutter betweendeck roof & house roof
Existing timber framed externalwall & associated windows &doors to be removed
Remove existing A/C unit
Proposed Ground Floor Lvl (R.L. 7.810)
Proposed First Floor Lvl (R.L 10.410)
Extg Ground Floor Lvl (Approx. R.L. 7.200)
Extg First Floor Lvl (Approx. R.L. 9.450)
LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)
ECEX
EC01
EC02
CB01
GP
DP
WEST ELEVATION PROPOSED
0mm 1000 2000 5000
SCALE 1:100 @ A32-
WEST ELEVATION EXISTING
0mm 1000 2000 5000
SCALE 1:100 @ A31-
Top Related