Diaphragm Seals With DPharp EJA and EJX Series Pressure Transmitters
Materials of Construction• 316(L) Stainless Steel• Hastelloy C-276• Monel 400• Titanium - Grade 4
Seal Process Connections• 1/2” through 1” NPT or BSP threaded• 1/2 “/DN15 through 4” /DN100 flanged,• 50-100-150-200-250 mm Extended
Diaphragm• Flushing Rings
Diaphragm Materials• 316L Stainless Steel• Hastelloy C-276• Monel K400• Tantalum• Titanium• Plastic coated 316• Inconel 600• Inconel 686• Nickel 200Note: Not all wetted parts materials
are listed in the model numbers. Please contact your Yokogawa Representative for further informations.
Connection Ratings• cl. 150# RF• cl. 300# RF Acc. ASME B16.5• cl. 600# RF• cl. 150-2500 RF• PN10• PN40 Acc. DIN (EN)• PN10-400• Sanitary
Capillaries and Connections• 316SS Armored Capillary• 316SS PVC Coated• 316SS, direct mount tube
GeneralSpecifications
Our remote or direct mount Diaphragm Seal is commonly used when process-operating conditions extend beyond the normal operating limits of a pressure transmitter. In addition, they are used to reduce the weight of the device at the process connection, particularly with conventional pressure transmitters. The lightweight design of DPharp EJA and EJX pressure transmitters combined with a robust direct-mounting system provide an excellent solution for both close-coupled and remote seal applications. Diaphragm seals are produced and mounted on Yokogawa Transmitters by Badotherm®.
For service where one or more of the following conditions exist:• High temperature• Clogging potential• Frequent cleaning requirements• Aggressive or abrasive processes• ANSI or DIN (EN) flanged including flush and extended process
connections• NPT threaded process connections• Sanitary connections• Pulp & Paper connections (flush diaphragm seal threaded)
Model Code DescriptionDFS-BF Diaphragm Seal blind flanged, available wetted parts materials are only stainless steel with several polymer coatingsDFS-BRF Diaphragm Seal blind flanged, however with the full range of wetted parts materials available (Hastelloy B & C, Inconel,
Monel, Nickel, Tantalum and Titanium)DFS-BC Diaphragm Seal cell type raised face, available wetted parts materials are only stainless steel with several polymer coatingsDFS-BRC Diaphragm Seal cell type raised face, however with the full range of wetted parts materials available (Hastelloy B & C,
Inconel, Monel, Nickel, Tantalum and Titanium)DFS-EXT Diaphragm Seal blind flanged with extension, with the full range of wetted parts materials available (Hastelloy B & C, Inconel,
Monel, Nickel, Tantalum and Titanium)DFS-USF Diaphragm Seal Universal flanged. These seals are used when you need to increase the diaphragm size without changing
the supplied process connector on either the vessel or pipelineDFS-USLF Diaphragm Seal Universal flanged, low pressure flanged typeDFS-UST Diaphragm Seal Universal threaded. These seals are used when you need to increase the diaphragm size without changing
the supplied process connector on either the vessel or pipelineDFS-USLT Diaphragm Seal Universal threaded, low pressure threaded typeDFS-PS Flush Diaphragm Seal Threaded PN600 DFS-ILS Diaphragm Seal (inline) available wetted parts materials are stainless steel onlyDFS-SA Diaphragm Seal with a selection of various sanitary process connectors, available wetted parts materials are stainless steel only
GS 06P01Y01-E-E3rd Edition
Functional Specifications (Common for DPHarp EJA & EJX Pressure Transmitters)*Refer to specific General Specification for more data
Output:Two wire 4 to 20mA DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol are superimposed on the 4 to 20mA signal.Output limits conforming to NAMUR NE43 can be pre-set by option code C2 or C3.Digital Communication via Foundation Fieldbus or Profibus PA are also available.
Zero Adjustment Limits:Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule.
External Zero Adjustment:External Zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the digital indicator with range-setting switch.
Ambient Temperature Limits:(Optional features or approval codes may affect limits.)-40 to 85 ºC (-40 to 185 ºF)-30 to 80 ºC (-22 to 176 ºF) with LCD display.
Process temperature Limits:Dependent on seal type and fill fluid selection.
Transmitter Capsule temperature Limits:(Optional features or approval codes may affect limits.)-40 to 120 ºC (-40 to 248 ºF)
Ambient Humidity Limits:0 to 100% RH (EJX)5 to 100% RH (EJA)
EMC Conformity Standard:EN 61326, AS/NZS CISPR11
Supply Voltage:10.5 to 42 VDC for general use and flameproof type10.5 to 32 VDC for lightning protector (option code /A).10.5 to 30VDC for intrinsically safe, type n or non-incendiveMinimum voltage limited at 16.6 VDC (EJX) and 16.4 VDC (EJA) for digital communication, BRAIN and HART
DPHarp transmitters combined with DFS Seals:
DP Transmitter EJX110A
For more details, please refer to the following GS:EJX110A GS01C25B01-01E
DP Transmitter EJA110A
For more details, please refer to the following GS :EJA110A GS01C21B01-00E
Gauge Pressure Transmitter EJX430AFor more details, please refer to the following GS :EJX430A GS01C25E01-01E
Gauge Pressure Transmitter EJA430AFor more details, please refer to the following GS :EJA430A GS01C21E01-01E
Absolute Pressure Transmitter EJX310A For more details, please refer to the following GS :EJX310A GS01C25D01-01E
Absolute Pressure Transmitter EJA310A For more details, please refer to the following GS :EJA310A GS01C21D01-01E
Absolute & Gauge Pressure Transmitter EJX�10A�� �30AEJX�10A�� �30ADFS seals can only be combined with Transmitter process connection “4” (1/2 “NPTf) or “W” (Welding connection for DFS)
For more details, please refer to the following GS :EJX510A, EJX530A GS01C25F01-01E
Absolute & Gauge Pressure Transmitter EJA�10A�� �30ADFS seals can only be combined with Transmitter process connection “4” (1/2 “NPTf) or “W” (Welding connection for DFS)
For more details, please refer to the following GS :EJA510A, EJA530A GS01C21F01-00E & -02E
GeneralSpecifications
<<Contents>> <<Index>>
EJX510A and EJX530AAbsolute and Gauge PressureTransmitter
Yokogawa Electric Corporation2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C25F01-01E
GS 01C25F01-01E©Copyright Jun. 20046th Edition Aug. 2005
The high performance absolute and gauge pressuretransmitter EJX510A and EJX530A feature singlecrystal silicon resonant sensor and are suitable tomeasure liquid, gas, or steam pressure. EJX510A andEJX530A output a 4 to 20 mA DC signal correspond-ing to the measured pressure. It also features quickresponse, remote setup and monitoring via BRAIN orHART communications, self-diagnostics, and optionalstatus output for pressure high/low alarm. FOUNDA-TION Fieldbus protocol type is also available.All EJX series models in their standard configuration,with the exception of the Fieldbus type, are certified byTÜV as complying with SIL 2 for safety requirement.
�STANDARD SPECIFICATIONSRefer to GS 01C25T02-01E for Fieldbus communica-tion type marked with “�.”
� SPAN AND RANGE LIMITS(For EJX510A, values are in absolute and lowerrange limits are 0.)
T01E.EPS
Span
SpanRange
Range
Range
RangeSpan
–1 to 20
1 to 50–1 to 1002 to 100
0.4 to 20
145 to 7200 10 to 500
8 to 200 kPa
–0.1 to 10
–0.1 to 20.04 to 2
–100 to 200 kPa
–14.5 to 14500.2 to 10
1.16 to 29–14.5 to 295.8 to 290
–14.5 to 29029 to 1450
Span–1 to 2
10 to 500–1 to 500–14.5 to 7200–0.1 to 50 –1 to 500
2 to 100
–1 to 2
kgf/cm2 (/D4)
0.08 to 2
0.4 to 20–1 to 20
–1 to 100
MPaMeasurementSpan/Range psi (/D1)
A
D
0.08 to 2
bar (/D3)
C
B
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code ʻSʼ and silicone oil, unlessotherwise mentioned.For Fieldbus communication type, use calibratedrange instead of span in the following specifications.
Specification ConformanceEJX series ensures specification conformance to atleast �3�.
Reference Accuracy of Calibrated Span(includes the effects of terminal-based linearity,hysteresis, and repeatability)
20 kPa(2.9 psi)
1 MPa(145 psi)
�0.1% of Span
0.2 MPa(29 psi)
DSpan � XSpan � X
Referenceaccuracy
10 MPa(1450 psi)
2 MPa(290 psi)
C
200 kPa(29 psi)
�(0.01+0.009 URL/Span) % of Span5 MPa
(720 psi)50 MPa
(7200 psi)
A
URL (Upper range limit)
Measurement span B
X
T02E.EPS
Ambient Temperature Effects per 28˚C (50˚F)Change
�(0.15% of Span + 0.15% of URL)Stability (All normal operating condition)
�0.1% of URL per 1 yearPower Supply Effects
�0.005% per Volt (from 21.6 to 32 V DC, 350 �)Vibration Effects
Amplifier housing code 1:Less than 0.1% of URL when tested per the require-ments of IEC60770-1 field or pipeline with highvibration level (10-60 Hz, 0.21 mm peak to peakdisplacement/60-2000 Hz 3 g)Amplifier housing code 2:Less than ±0.1% of URL when tested per therequirements of IEC60770-1 field with generalapplication or pipeline with low vibration level (10-60Hz 0.15mm peak to peak displacement /60-500 Hz2g)
Mounting Position EffectsRotation in diaphragm plane has no effect. Tilting upto 90 degree will cause zero shift up to 0.21 kPa(0.84 inH2O) which can be corrected by the zeroadjustment.
Response Time (All capsules) “�”90 msecWhen software damping is set to zero and includingdead time of 45 msec (nominal)
GeneralSpecifications
<<Contents>> <<Index>>
The absolute and gauge pressure transmitter modelEJA510A and EJA530A can be used to measureliquid, gas, or steam pressure. Both output a 4 to 20mA DC signal corresponding to the measured pres-sure, and also feature remote setup and monitoringthrough communications with the BRAIN™ terminaland CENTUM CS™ or µXL™ or HART® 275 host.
� STANDARD SPECIFICATIONSRefer to GS 01C22T02-00E for Fieldbuscommunication type marked with “�”.
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code ʻSʼ and silicone oil.
Reference Accuracy of Calibrated Span(including the effects of zero-based linearity, hyster-esis, and repeatability, values are in absolute forEJA510A)�0.2 % of Span
�0.075 % of Span, when/ HAC is specified(EJA530A: A, B and C capsule)
�0.12 % of Span, when/ HAC is specified(EJA530A: D capsule)
For spans below X,
�[0.05�0.15 ] % of Span
�[0.025�0.05 ] % of span, when/ HAC is
specified (EJA530A: A, B and C capsule)
�[0.03�0.09 ] % of span, when/ HAC is
specified (EJA530A: D capsule)
XSpan
XSpan
XSpan
Where X equals:Capsule X MPa {psi}A 20 kPa {2.9}A with/ HAC 40 kPa {5.8}B 0.2 {29}C 1 {145}D 8 {1160}
Ambient Temperature EffectsTotal Effects per 28 �C (50 �F) Change
�[0.15% Span � 0.15% URL]Stability
�0.1% of URL per 12 monthsVibration Effects
�0.1 % of URL(5 to 15Hz; 4mm peak-to-peak constant displace-ment, 15 to 150Hz; 2g, 150 to 2000Hz; 1g)
Model EJA510A and EJA530AAbsolute and Gauge PressureTransmitters
Yokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C21F01-00E
GS 01C21F01-00E©Copyright Apr. 1999
15th Edition Jan. 2005
Power Supply Effects “�”�0.005 % per Volt (from 21.6 to 32 V DC, 350 �)
� FUNCTIONAL SPECIFICATIONSSpan & Range Limits(Values are in absolute for EJA510A)
A
B
MeasurementSpan and
RangeSpan
Range
SpanRange
psi (/D1)
1.45 to 29
0 to 29
14.5 to 2900 to 290
bar (/D3)
0.1 to 2
kgf/cm2(/D4)
0.1 to 2
0 to 2
1 to 200 to 20
0 to 2
1 to 200 to 20
MPa
10 to 200kPa
0 to 200kPa
0.1 to 20 to 2
72.5 to 14500.5 to 10
0 to 10C
SpanRange 0 to 1450
5 to 1000 to 100
5 to 1000 to 100
720 to 72005 to 50
0 to 50D
SpanRange 0 to 7200
50 to 5000 to 500
50 to 5000 to 500
T01E.EPS
URL is defined as the Upper Range Limit from thetable above.
Zero Adjustment LimitsZero can be fully elevated or suppressed, within theLower and Upper Range Limits of the capsule.
External Zero Adjustment “�”External zero is continuously adjustable with 0.01 %incremental resolution of span. Span may beadjusted locally using the digital indicator with rangeswitch.
Mounting Position EffectRotation in diaphragm plane has no effect. Tilting upto 90� will cause zero shift up to 0.27 kPa {1.1 inH2O}which can be corrected by the zero adjustment.
Output “�”Two wire 4 to 20 mA DC output with digital communi-cations. BRAIN or HART FSK protocol are superim-posed on the 4 to 20 mA signal.
[Style: S2]
2
GeneralSpecifications
<<Contents>> <<Index>>
EJX110ADifferential Pressure Transmitter
Yokogawa Electric Corporation2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C25B01-01E
GS 01C25B01-01E©Copyright Feb. 20049th Edition May 2008
The high performance differential pressure transmitterEJX110A features single crystal silicon resonantsensor and is suitable to measure liquid, gas, orsteam flow as well as liquid level, density and pres-sure. EJX110A outputs a 4 to 20 mA DC signalcorresponding to the measured differential pressure.Its highly accurate and stable sensor can also mea-sure the static pressure which can be shown on theintegral indicator or remotely monitored via BRAIN orHART communications. Other key features includequick response, remote set-up using communications,self-diagnostics and optional status output for pressurehigh/low alarm. FOUNDATION Fieldbus protocol typeis also available. All EJX series models in theirstandard configuration, with the exception of theFieldbus type, are certified by TÜV as complying withSIL 2 for safety requirement.
�STANDARD SPECIFICATIONSRefer to GS 01C25T02-01E for Fieldbus communica-tion type marked with “�.”
� SPAN AND RANGE LIMITSMeasurement Span/Range
L
M
H
0.1 to 10
–100 to 100
–5 to 5 kgf/cm2
Span
Span
Span
Range
Range
Range
kPa
0.4 to 40–40 to 40
–400 to 4002 to 400
–10 to 100.5 to 100
2.5 to 500–500 to 500
inH2O(/D1)
10 to 2000–2000 to 2000
mbar(/D3)
1 to 100
–1000 to 1000
–100 to 1005 to 1000
25 to 5000–5000 to 5000
mmH2O(/D4)
10 to 1000–1000 to 1000
50 to 10000–10000 to 100000.025 to 5 kgf/cm2
V –5 to 140 kgf/cm2SpanRange
0.07 to 14 MPa–0.5 to 14 MPa
10 to 2000 psi–71 to 2000 psi
0.7 to 140 bar–5 to 140 bar
0.7 to 140 kgf/cm2
T01E.EPS
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code S and silicone oil, unless other-wise mentioned.For Fieldbus communication type, use calibratedrange instead of span in the following specifications.
Specification ConformanceEJX series ensures specification conformance to atleast �3�.
Reference Accuracy of Calibrated Span(includes terminal-based linearity, hysteresis, andrepeatability)Measurement span
Referenceaccuracy
�0.04% of Span�(0.005�0.0035 URL/span)% of Span
M
T02E.EPS
XX � span
X � span
URL (upper range limit)10 kPa (40 inH2O)
100 kPa (400 inH2O)
Measurement spanReferenceaccuracy
�0.04% of Span�(0.005�0.0049 URL/span)% of Span
T08E.EPS
XX � span
X � span
URL (upper range limit)
H
70 kPa (280 inH2O)500 kPa (2000 inH2O)
Measurement spanReferenceaccuracy
�0.04% of Span
�(0.005+0.00125 URL/span)% of Span
T09E.EPS
XX � span
X � span
URL (upper range limit)
V
500 kPa (2000 inH2O)14 MPa (2000 psi)
Measurement span
Referenceaccuracy
�0.04% of Span�(0.015�0.005 URL/span)% of Span
L
T03E.EPS
XX � span
X � span
URL (upper range limit)2 kPa (8 inH2O)
10 kPa (40 inH2O)
Square Root Output AccuracyThe square root accuracy is a percent of flow span.
Output Accuracy50% or Greater Same as reference accuracy
50% to Dropout point
T03E.EPS
Reference accuracy�50Square root output (%)
Ambient Temperature Effects per 28˚C (50˚F)Change
Capsule EffectM �(0.04% Span�0.009% URL)H , V �(0.04% Span�0.0125% URL)L �(0.055% Span�0.09% URL)
[Style: S3]
GeneralSpecifications
<<Contents>> <<Index>>
Model EJA110ADifferential Pressure Transmitter
Yokogawa Electric Corporation2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C21B01-00E
GS 01C21B01-00E©Copyright June 199720th Edition Jan. 2005
The high performance differential pressure transmittermodel EJA110A can be used to measure liquid, gas,or steam flow as well as liquid level, density andpressure. It outputs a 4 to 20 mA DC signal corre-sponding to the measured differential pressure. ModelEJA110A also features remote setup and monitoringthrough communications with the BRAIN™ terminaland CENTUM CS™ or �XL™ or HART® 275 host.
�STANDARD SPECIFICATIONSRefer to GS 01C22T02-00E for Fieldbus communica-tion type marked with “�.”
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code ʻSʼ and silicone oil.
Reference Accuracy of Calibrated Span(including the effects of zero-based linearity, hyster-esis, and repeatability)
�0.075 % of Span
For spans below X
�[0.025 + 0.05 ] % of SpanXSpan
where X equals:Capsule X kPa {inH2O}L 3 {12}M 10 {40}H 100 {400}V 1.4 MPa {200 psi}
Square Root Output AccuracyThe square root accuracy is a percent of flow span.
Output Accuracy
50 % or Greater same as referenceaccuracy
50 % to Dropout point reference accuracy�50square root output (%)
T00E.EPS
Ambient Temperature EffectsTotal Effects per 28 ˚C (50 ˚F) Change
Capsule EffectL �[0.08 % Span + 0.09 % URL]M �[0.07 % Span + 0.02 % URL]H �[0.07 % Span + 0.015 % URL]V �[0.07 % Span + 0.03 % URL]
Static Pressure EffectsTotal Effects per ChangeL capsule�[0.07 % Span+0.052 % URL] per 3.4 MPa {500 psi}M, H and V capsules�[0.1% Span+0.028 % URL] per 6.9 MPa {1000 psi}
Effect on Zero (can be corrected at line pres-sure)L capsule�[0.02 % Span+0.052 % URL] per 3.4 MPa {500 psi}
M, H and V capsules�0.028 % of URL per 6.9 MPa {1000 psi}
Overpressure Effects (M, H and V capsules)�0.03 % of URL per 16 MPa {2300 psi}
Stability (M, H and V capsules)�0.1 % of URL per 60 months
Power Supply Effects “�”�0.005 % per Volt (from 21.6 to 32 V DC, 350 �)
� FUNCTIONAL SPECIFICATIONSSpan & Range LimitsMeasurement Span/Range
L
M
H
0.5 to 10
-100 to 100
-5 to 5 kgf/cm2
Span
Span
Span
Range
Range
Range
kPa
2 to 40-40 to 40
-400 to 4004 to 400
-10 to 101 to 100
5 to 500-500 to 500
inH2O(/D1)
20 to 2000-2000 to 2000
mbar(/D3)
5 to 100
-1000 to 1000
-100 to 10010 to 1000
50 to 5000-5000 to 5000
mmH2O(/D4)
50 to 1000-1000 to 1000100 to 10000
-10000 to 100000.05 to 5 kgf/cm2
T01E.EPS
V*1SpanRange -5 to 140 kgf/cm2
0.14 to 14 MPa-0.5 to 14 MPa
20 to 2000 psi-71 to 2000 psi
1.4 to 140 bar-5 to 140 bar
1.4 to 140 kgf/cm2
*1: For Wetted parts material code other than S, theranges are 0 to 14 MPa, 0 to 2000 psi, 0 to 140bar, and 0 to 140 kgf/cm2.
URL is defined as the Upper Range Limit from the tableabove.
Zero Adjustment LimitsZero can be fully elevated or suppressed, within theLower and Upper Range Limits of the capsule.
External Zero Adjustment “�”External zero is continuously adjustable with 0.01 %incremental resolution of span. Span may beadjusted locally using the digital indicator with rangeswitch.
GeneralSpecifications
<<Contents>> <<Index>>
Model EJA110ADifferential Pressure Transmitter
Yokogawa Electric Corporation2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C21B01-00E
GS 01C21B01-00E©Copyright June 199720th Edition Jan. 2005
The high performance differential pressure transmittermodel EJA110A can be used to measure liquid, gas,or steam flow as well as liquid level, density andpressure. It outputs a 4 to 20 mA DC signal corre-sponding to the measured differential pressure. ModelEJA110A also features remote setup and monitoringthrough communications with the BRAIN™ terminaland CENTUM CS™ or �XL™ or HART® 275 host.
�STANDARD SPECIFICATIONSRefer to GS 01C22T02-00E for Fieldbus communica-tion type marked with “�.”
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code ʻSʼ and silicone oil.
Reference Accuracy of Calibrated Span(including the effects of zero-based linearity, hyster-esis, and repeatability)
�0.075 % of Span
For spans below X
�[0.025 + 0.05 ] % of SpanXSpan
where X equals:Capsule X kPa {inH2O}L 3 {12}M 10 {40}H 100 {400}V 1.4 MPa {200 psi}
Square Root Output AccuracyThe square root accuracy is a percent of flow span.
Output Accuracy
50 % or Greater same as referenceaccuracy
50 % to Dropout point reference accuracy�50square root output (%)
T00E.EPS
Ambient Temperature EffectsTotal Effects per 28 ˚C (50 ˚F) Change
Capsule EffectL �[0.08 % Span + 0.09 % URL]M �[0.07 % Span + 0.02 % URL]H �[0.07 % Span + 0.015 % URL]V �[0.07 % Span + 0.03 % URL]
Static Pressure EffectsTotal Effects per ChangeL capsule�[0.07 % Span+0.052 % URL] per 3.4 MPa {500 psi}M, H and V capsules�[0.1% Span+0.028 % URL] per 6.9 MPa {1000 psi}
Effect on Zero (can be corrected at line pres-sure)L capsule�[0.02 % Span+0.052 % URL] per 3.4 MPa {500 psi}
M, H and V capsules�0.028 % of URL per 6.9 MPa {1000 psi}
Overpressure Effects (M, H and V capsules)�0.03 % of URL per 16 MPa {2300 psi}
Stability (M, H and V capsules)�0.1 % of URL per 60 months
Power Supply Effects “�”�0.005 % per Volt (from 21.6 to 32 V DC, 350 �)
� FUNCTIONAL SPECIFICATIONSSpan & Range LimitsMeasurement Span/Range
L
M
H
0.5 to 10
-100 to 100
-5 to 5 kgf/cm2
Span
Span
Span
Range
Range
Range
kPa
2 to 40-40 to 40
-400 to 4004 to 400
-10 to 101 to 100
5 to 500-500 to 500
inH2O(/D1)
20 to 2000-2000 to 2000
mbar(/D3)
5 to 100
-1000 to 1000
-100 to 10010 to 1000
50 to 5000-5000 to 5000
mmH2O(/D4)
50 to 1000-1000 to 1000100 to 10000
-10000 to 100000.05 to 5 kgf/cm2
T01E.EPS
V*1SpanRange -5 to 140 kgf/cm2
0.14 to 14 MPa-0.5 to 14 MPa
20 to 2000 psi-71 to 2000 psi
1.4 to 140 bar-5 to 140 bar
1.4 to 140 kgf/cm2
*1: For Wetted parts material code other than S, theranges are 0 to 14 MPa, 0 to 2000 psi, 0 to 140bar, and 0 to 140 kgf/cm2.
URL is defined as the Upper Range Limit from the tableabove.
Zero Adjustment LimitsZero can be fully elevated or suppressed, within theLower and Upper Range Limits of the capsule.
External Zero Adjustment “�”External zero is continuously adjustable with 0.01 %incremental resolution of span. Span may beadjusted locally using the digital indicator with rangeswitch.
GeneralSpecifications
<<Contents>> <<Index>>
EJX110ADifferential Pressure Transmitter
Yokogawa Electric Corporation2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 JapanPhone: 81-422-52-5690 Fax.: 81-422-52-2018
GS 01C25B01-01E
GS 01C25B01-01E©Copyright Feb. 20049th Edition May 2008
The high performance differential pressure transmitterEJX110A features single crystal silicon resonantsensor and is suitable to measure liquid, gas, orsteam flow as well as liquid level, density and pres-sure. EJX110A outputs a 4 to 20 mA DC signalcorresponding to the measured differential pressure.Its highly accurate and stable sensor can also mea-sure the static pressure which can be shown on theintegral indicator or remotely monitored via BRAIN orHART communications. Other key features includequick response, remote set-up using communications,self-diagnostics and optional status output for pressurehigh/low alarm. FOUNDATION Fieldbus protocol typeis also available. All EJX series models in theirstandard configuration, with the exception of theFieldbus type, are certified by TÜV as complying withSIL 2 for safety requirement.
�STANDARD SPECIFICATIONSRefer to GS 01C25T02-01E for Fieldbus communica-tion type marked with “�.”
� SPAN AND RANGE LIMITSMeasurement Span/Range
L
M
H
0.1 to 10
–100 to 100
–5 to 5 kgf/cm2
Span
Span
Span
Range
Range
Range
kPa
0.4 to 40–40 to 40
–400 to 4002 to 400
–10 to 100.5 to 100
2.5 to 500–500 to 500
inH2O(/D1)
10 to 2000–2000 to 2000
mbar(/D3)
1 to 100
–1000 to 1000
–100 to 1005 to 1000
25 to 5000–5000 to 5000
mmH2O(/D4)
10 to 1000–1000 to 1000
50 to 10000–10000 to 100000.025 to 5 kgf/cm2
V –5 to 140 kgf/cm2SpanRange
0.07 to 14 MPa–0.5 to 14 MPa
10 to 2000 psi–71 to 2000 psi
0.7 to 140 bar–5 to 140 bar
0.7 to 140 kgf/cm2
T01E.EPS
� PERFORMANCE SPECIFICATIONSZero-based calibrated span, linear output, wettedparts material code S and silicone oil, unless other-wise mentioned.For Fieldbus communication type, use calibratedrange instead of span in the following specifications.
Specification ConformanceEJX series ensures specification conformance to atleast �3�.
Reference Accuracy of Calibrated Span(includes terminal-based linearity, hysteresis, andrepeatability)Measurement span
Referenceaccuracy
�0.04% of Span�(0.005�0.0035 URL/span)% of Span
M
T02E.EPS
XX � span
X � span
URL (upper range limit)10 kPa (40 inH2O)
100 kPa (400 inH2O)
Measurement spanReferenceaccuracy
�0.04% of Span�(0.005�0.0049 URL/span)% of Span
T08E.EPS
XX � span
X � span
URL (upper range limit)
H
70 kPa (280 inH2O)500 kPa (2000 inH2O)
Measurement spanReferenceaccuracy
�0.04% of Span
�(0.005+0.00125 URL/span)% of Span
T09E.EPS
XX � span
X � span
URL (upper range limit)
V
500 kPa (2000 inH2O)14 MPa (2000 psi)
Measurement span
Referenceaccuracy
�0.04% of Span�(0.015�0.005 URL/span)% of Span
L
T03E.EPS
XX � span
X � span
URL (upper range limit)2 kPa (8 inH2O)
10 kPa (40 inH2O)
Square Root Output AccuracyThe square root accuracy is a percent of flow span.
Output Accuracy50% or Greater Same as reference accuracy
50% to Dropout point
T03E.EPS
Reference accuracy�50Square root output (%)
Ambient Temperature Effects per 28˚C (50˚F)Change
Capsule EffectM �(0.04% Span�0.009% URL)H , V �(0.04% Span�0.0125% URL)L �(0.055% Span�0.09% URL)
[Style: S3]
CertificatesEach set is delivered as standard with 3.1 Material Certificate and Test Certificate (which includes calibration and hydrostatic pressure tests).
Following options are available (refer to specific DFS models)./XM11 Without 3.1 Material Certificate/NACE MR0175-2003 (with HC Diaphragm material)
DFS-BF/BRF DFS-BC/BRC DFS-EXT DFS-USF/USLF
DFS-UST/USLT DFS-ILS DFS-SA DFS-PS
3
Flushing Rings for DFS -BF /-BRF /-BC /-BRC/FR01 Flushing ring mat. 316; 1 x 1/4” NPTf 2”/DN50 RF/FR02 Flushing ring mat. 316; 2 x 1/4” NPTf 2”/DN50 RF/FR03 Flushing ring mat. 316; 1 x 1/2” NPTf 2”/DN50 RF/FR04 Flushing ring mat. 316; 2 x 1/2” NPTf 2”/DN50 RF/FR05 Flushing ring mat. 316; 1 x 1/4” NPTf 3”/DN80 RF/FR06 Flushing ring mat. 316; 2 x 1/4” NPTf 3”/DN80 RF/FR07 Flushing ring mat. 316; 1 x 1/2” NPTf 3”/DN80 RF/FR08 Flushing ring mat. 316; 2 x 1/2” NPTf 3”/DN80 RF
Fill FluidsWe provide a wide array of fill fluids, which will encompass the majority of applications. Table below shows the fill fluids available and the physical parameters of each.
Code Temp. limits1 Description Density at 2�ºC BSO reference-F1 -10 to 350°C Silicon Oil 1.07 42-F2 -40 to 250°C Fluorinated Oil for Oxygen & Chlorine service 1.87 25-F3 -40 to 200°C Silicon Oil 0.95 22-F4 -15 to 205°C NEOBee M20 FDA approved fill fluid 0.92 40-F5 -40 to 399°C Silicon Oil 0.93 02-F6 -80 to 100°C Fluorinated Oil 1.82 03-F7 -10 to 315°C Silicon Oil 1.07 18-F8 -40 to 315°C Silicon Oil 1.07 21-F9 -40 to 120ºC Silicon Oil (fast responce time) 0.92 41
Temperature limits are dependant upon operating pressure. Please check this.
See next pages for specifications and ordering information.
Badotherm diapragm seals product overview
GS 06P01Y01-E-E
4
SIZE RATING b f d4 K D C1 (mm) (mm) (mm) (mm) (mm) pcs size thread L 1/2” 150 # 11,2 1,6 35,1 60,5 88,9 4 15,7 1/2”-13UNC 17 1/2” 300 # 14,2 1,6 35,1 66,5 95,2 4 15,7 1/2”-13UNC 17 1/2” 400-600# 20,6 6,4 35,1 66,5 95,3 4 15,7 1/2”-13UNC 17 1/2” 900-150# 28,7 6,4 35,1 82,5 120,6 4 22,3 3/4”-10UNC 25 1/2” 2500# 36,6 6,4 35,1 88,5 133,4 4 22,3 3/4”-10UNC 25 3/4” 150# 12,7 1,6 42,9 69,9 98,6 4 15,7 1/2”-13UNC 17 3/4” 300# 15,7 1,6 42,9 82,5 117,3 4 19,1 5/8”-11UNC 20 3/4” 400-600# 22,1 6,4 42,9 82,5 117,3 4 19,1 5/8”-11UNC 20 3/4” 900-150# 31,8 6,4 42,9 88,9 130,0 4 22,3 3/4”-10UNC 25 3/4” 2500# 38,2 6,4 42,9 95,3 139,7 4 22,3 3/4”-10UNC 25 1” 150# 14,2 1,6 50,8 79,2 108,0 4 15,7 1/2”-13UNC 17 1” 300# 17,5 1,6 50,8 88,9 123,9 4 19,1 5/8”-11UNC 20 1” 400-600# 23,9 6,4 50,8 88,9 124,0 4 19,1 5/8”-11UNC 20 1” 900-150# 34,8 6,4 50,8 101,6 149,3 4 25,4 7/8”-9UNC 28 1” 2500# 41,5 6,4 50,8 108,0 158,8 4 25,4 7/8”-9UNC 28 11/4” 150# 15,7 1,6 63,5 88,9 117,3 4 15,7 1/2”-13UNC 17 11/4” 300# 19,0 1,6 63,5 98,5 133,3 4 19,1 5/8”-11UNC 20 11/4” 400-600# 27,0 6,4 63,5 98,5 133,4 4 19,1 5/8”-11UNC 20 11/4” 900-150# 34,8 6,4 63,5 111,2 158,7 4 25,4 7/8”-9UNC 28 11/4” 2500# 44,5 6,4 63,5 130,0 184,2 4 28,4 1”-8UNC 32 11/2” 150# 17,5 1,6 73,2 98,6 127,0 4 15,7 1/2”-13UNC 17 11/2” 300# 20,6 1,6 73,2 114,3 155,4 4 22,3 3/4”-10UNC 25 11/2” 400-600# 28,8 6,4 73,2 114,3 155,4 4 22,3 3/4”-10UNC 25 11/2” 900-150# 38,1 6,4 73,2 123,9 177,8 4 28,4 1”-8UNC 32 11/2” 2500# 50,9 6,4 73,2 146,1 203,2 4 31,8 11/8”-UNC 38 2” 150# 19,1 1,6 91,9 120,7 152,4 4 19,1 5/8”-11UNC 20 2” 300# 22,4 1,6 91,9 127,0 165,1 8 19,1 5/8”-11UNC 20 2” 400-600# 31,8 6,4 91,9 127,0 165,1 8 19,1 5/8”-11UNC 20 2” 900-150# 44,5 6,4 91,9 165,1 215,9 8 25,4 7/8”-9UNC 28 2” 2500# 57,2 6,4 91,9 171,5 235,0 8 28,4 1”-8UNC 32 3” 150# 23,9 1,6 127,0 152,4 190,5 4 19,1 5/8”-11UNC 20 3” 300# 28,4 1,6 127,0 168,1 209,5 8 22,3 3/4”-10UNC 25 3” 400-600# 38,2 6,4 127,0 168,1 209,6 8 22,3 3/4”-10UNC 25 3” 900# 44,5 6,4 127,0 190,5 241,3 8 25,4 7/8”-9UNC 28 3” 1500# 54,1 6,4 127,0 203,2 266,7 8 31,8 11/8”-8UNC 38 3” 2500# 72,9 6,4 127,0 228,6 304,8 8 35,1 11/4”-8UNC 41 4” 150# 23,9 1,6 157,2 190,5 228,6 8 19,1 5/8”-11UNC 20 4” 300# 31,7 1,6 157,2 200,1 254,0 8 22,3 3/4”-10UNC 25 4” 400# 37,9 6,4 157,2 200,2 254,0 8 25,4 7/8”-9UNC 28 4” 600# 44,5 6,4 157,2 215,9 273,1 8 25,4 7/8”-9UNC 28 4” 900# 50,8 6,4 157,2 234,9 292,1 8 25,4 11/8”-8UNC 28 4” 1500# 50,2 6,4 157,2 241,3 311,1 8 35,1 11/4”-8UNC 41 4” 2500# 82,6 6,4 157,2 273,1 355,6 8 41,1 11/2”-8UNC 48
Process flanges according to ASME 16.�
GS 06P01Y01-E-E
5
B A b f d4 k D C1 DN PN pc size thread 15 2.5-6 12 2 40 55 80 4 11 M10 15 10-40 16 2 45 65 95 4 14 M12 15 20 12 1.6 34.9 60.3 89 4 15.8 M14 15 50 14.21. 6 39.9 66.7 95 4 15.8 M14 15 63-100 20 2 45 75 105 4 14 M12 20 2.5-6 14 2 50 65 90 4 11 M10 20 10-40 18 2 58 75 105 4 14 M12 20 20 14 1.6 42.9 69.8 99 4 15.8 M14 20 50 15.7 1.6 42.9 82.6 117 4 19 M16 20 63-100 22 2 58 90 130 4 18 M16 25 2.5-6 14 2 60 75 100 4 11 M10 25 10-40 18 2 68 85 115 4 14 M12 25 20 16 1.6 50.8 79.4 108 4 15.8 M14 25 50 17.5 1.6 50.8 88.9 124 4 19 M16 25 63-100 24 2 68 100 140 4 18 M16 32 2.5-6 14 2 70 90 120 4 14 M12 32 10-40 18 2 78 100 140 4 18 M16 32 20 18 1.6 63.5 88.9 117 4 15.8 M14 32 50 19 1.6 63.5 98.4 133 4 19 M16 32 63-100 26 2 78 110 155 4 22 M20 40 2.5-6 14 2 80 100 130 4 14 M12 40 10-40 18 2 88 110 150 4 18 M16 40 20 19 1.6 73 98.4 127 4 15.8 M14 40 50 20.6 1.6 73 114.3 156 4 22.2 M20 40 63-100 28 2 88 125 170 4 22 M20 50 2.5-6 14 2 90 110 140 4 14 M12 50 10-16 18 2 102 125 165 4 18 M16 50 20 21 1.6 92.1 120.6 152 4 19 M16 50 25-40 20 2 102 125 165 4 18 M16 50 50 22.4 1.6 92.1 127 165 8 19 M16 50 63 26 2 102 135 180 4 22 M20 50 100 30 2 102 145 195 4 26 M24 80 2.5-6 16 2 128 150 190 4 18 M16 80 10-16 20 2 138 160 200 8 18 M16 80 20 26 1.6 127 152.4 190 4 19 M16 80 25-40 24 2 138 160 200 8 18 M16 80 50 28.4 1.6 127 168.3 210 8 22.2 M20 80 63 28 2 138 170 215 8 22 M20 80 100 36 2 138 180 230 8 26 M24 100 2.5-6 16 2 148 170 210 4 18 M16 100 10-16 20 2 158 180 220 8 18 M16 100 20 27 1.6 157.2 190.5 229 8 19 M16 100 25-40 24 2 158 190 235 8 22 M20 100 50 31.8 1.6 157.2 200 254 8 22.2 M20 100 63 30 2 162 200 250 8 26 M24 100 100 40 2 162 210 265 8 30 M27
Process flanges according to DIN EN 1092-1
GS 06P01Y01-E-E
6
Diaphragm seal BF flush diaphragm�� flanged type
Model and Suffix codes DFS-BF
Model Suffixcode DescriptionDFS-BF Diaphragm Seal - Blind flange��
Raised FaceFlange -02 25 mm, 1” Size -04 40 mm, 1 1/2” -05 50 mm, 2” -08 80 mm, 3” -10 100 mm, 4”Flange rating A1 ANSI class 150 (PSI) A2 ANSI class 300 (PSI) A4 ANSI class 600 (PSI) D1 (note 1) DIN PN10 (bar) flange D3 (note 1) DIN PN25 (bar) flange D4 DIN PN40 (bar) flangeFlange Material SS Stainless Steel AISI-316 LDiaphragm Material SS Stainless Steel AISI 316-L HC Hastelloy C276 (NACE) ET Coating ECTFE FE Coating FEP PF Coating PFA PT Coating PTFE PV Coating PVDF AG Electro-plated Silver 10 um AU Electro-plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 -40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Standard fill fluid -F4 -15 to 205°C NEOBee M20 FDA appr. fill fluid -F5 - 40 to 399°C Silicon Oil -F6 - 80 to 100°C Fluorinated Oil -F7 - 10 to 315°C Silicon Oil -F8 - 40 to 315°C Silicon Oil -F9 - 40 to 120ºC Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured Axial C2 Stainless Steel Armoured with PVC protection sleeve Axial C3 Stainless Steel Armoured Radial C4 Stainless Steel Armoured + PVC Radial NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction
Recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /FRxx See page 3 for flushing rings /NACE MR0175-2003 (select HC)
Capillary execution
Threaded execution
Note 1: only available for 100mm, 4” flange size
GS 06P01Y01-E-E
7
Technical specification model BF
Flanged connectionASME 1” 11/2” / 2” 2” 3” 3” / 4”DIN DN2� DN40/�0 DN�0 DN80 DN80/100Diaphragm size in mm 32 44 57 72 89Max. process pressure in bar at 20 °C 414 414 414 414 414Max. capillary length in meter 6 10 15 15 15Min. pressure range for PI in bar 2.5 1.6 0.6 0.5 0.5Min. span for GP & AP in mbar 4000 1250 600 200 80Min. span for DP in mbar n.a. 300 100 20 10
Process connection Standard OptionsASME B 16.5 1” / 11/2” / 2” / 3” / 4” Other sizes acc ASME 150 / 300 / 600# > 600# RF FF, groove, RJ,RTJ Ra 3.2…6.3 µm Other finishesDIN 2501 (EN 1092-1 ) DN25 / 40 / 50 / 80 / 100 Other sizes acc DIN PN10 / 25 / 40 > 40 bar Form D-DIN2526, (Form B1) Other types and finishesJIS On request
Wetted parts Standard OptionsFlange AISI316 (L) Custom designDiaphragm(weld in process) AISI316L
Instrument connection Standard OptionsCapillary tubing Top entry Side entryThreaded 1/2 bsp female Other sizes
Features Standard OptionsCapillary tubing AISI316 Side entry PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsFlushing rings For all DIN, ANSI flangesSupport handle On all flanges above 600#Support pipe Heavy duty pipe on capillaryBAsecal calculation All transmitters with sealsCalibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange Flange GP AP DP 44 mm DN50 2” 1250 1250 300 57 mm DN50 2” 600 600 100 72 mm DN80 3” 200 200 20 89 mm DN80 3” 80 80 10 89 mm DN100 4” 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 44 mm DN50 2” 0.20 1.24 2.28 1.90 4.90 10.3 57 mm DN50 2” 0.15 0.66 0.63 1.70 2.65 3.9 72 mm DN80 3” 0.10 0.24 0.20 0.55 0.95 1.2 89 mm DN80 3” 0.04 0.09 0.08 0.19 0.39 0.4 89 mm DN100 4” 0.04 0.09 0.08 0.19 0.39 0.4
Temperature effect is per +10 °C and measured from 20 °C.
Diaphragm seal BRF flush diaphragm�� flanged type
GS 06P01Y01-E-E
8
Capillary execution
Threaded execution
Model and Suffix codes DFS-BRF
Model Suffixcode DescriptionDFS-BRF Diaphragm Seal - Blind flange�� Raised FaceFlange -02 25 mm, 1” Size -04 40 mm, 1 1/2” -05 50 mm, 2” -08 80 mm, 3” -10 100 mm, 4”Flange rating A1 ANSI class 150 (PSI) A2 ANSI class 300 (PSI) A4 ANSI class 600 (PSI) D1 (note 1) DIN PN10 (bar) flange D3 (note 1) DIN PN25 (bar) flange D4 DIN PN40 (bar) flangeFlange Material SS Stainless Steel AISI-316 LDiaphragm Material / SS Stainless Steel AISI-316 L Coatings HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI TitaniumFill Fluid -F1 -10 to 350°C Silicon Oil -F2 -40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Fill Fluid -F4 -15 to 205°C NEOBee M20 FDA approved fill fluid -F5 - 40 to 399°C Silicon Oil -F6 - 80 to 100°C Fluorinated Oil -F7 - 10 to 315°C Silicon Oil -F8 - 40 to 315°C Silicon Oil -F9 - 40 to 120°C Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured Axial C2 Stainless Steel Armoured with PVC protection sleeve Axial C3 Stainless Steel Armoured Radial C4 Stainless Steel Armoured + PVC Radial NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended
for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (app. F2 fill) /XM11 Without 3.1 Material Certificate /FRxx See page 3 for flushing rings /NACE MR0175-2003 (select HC)
Note 1: only available for 100mm, 4” flange size
GS 06P01Y01-E-E
9
Technical specification model BRF
Flanged connectionASME 1” 11/2” / 2” 2” 3” 3” / 4”DIN DN2� DN40/�0 DN�0 DN80 DN80/100Diaphragm size in mm 32 44 57 72 89Max. process pressure in bar at 20 °C 414 414 414 414 414Max. capillary length in meter 6 10 15 15 15Min. pressure range for PI in bar 2.5 1.6 0.6 0.5 0.5Min. span for GP & AP in mbar 4000 1250 600 200 80Min. span for DP in mbar n.a. 300 100 20 10
Process connection Standard OptionsASME B 16.5 1” / 11/2” / 2” / 3” / 4” Other sizes acc ASME 150 / 300 / 600# > 600# RF Other facing Factory standard face finishDIN 2501 (EN 1092-1 ) DN25 / 40 / 50 / 80 / 100 Other sizes acc DIN PN10 / 25 / 40 > 40 bar Factory standard face finishJIS On request
Wetted parts Standard OptionsFlange AISI316 (L) Exotic materialsDiaphragm Hastelloy B2, Monel(fully covered raised face) Hastelloy C276 Tantalum, Silver, AISI316L Inconel 600
Instrument connection Standard OptionsCapillary tubing Top entry Side entryThreaded 1/2 bsp female Other sizes
Features Standard OptionsCapillary tubing AISI316 Side entryArmoring AISI304 PVC sleeve blackDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsFlushing rings For all DIN, ANSI flangesSupport handle On all flanges above 600#Support pipe Heavy duty pipe on capillaryBAsecal calculation All transmitters with sealsCalibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange Flange GP AP DP 44 mm DN50 2” 1250 1250 300 57 mm DN50 2” 600 600 100 72 mm DN80 3” 200 200 20 89 mm DN80 3” 80 80 10 89 mm DN100 4” 80 80 10
Temperature effect from transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 44 mm DN50 2” 0.20 1.24 2.28 1.90 4.90 10.3 57 mm DN50 2” 0.15 0.66 0.63 1.70 2.65 3.9 72 mm DN80 3” 0.10 0.24 0.20 0.55 0.95 1.2 89 mm DN80 3” 0.04 0.09 0.08 0.19 0.39 0.4 89 mm DN100 4” 0.04 0.09 0.08 0.19 0.39 0.4
Temperature effect is per +10 °C and measured from 20 °C.
Diaphragm seal BC flush diaphragm�� cell type
Model and Suffix codes DFS-BC
Model Suffixcode DescriptionDFS-BC Diaphragm Seal - cell type�� Raised FaceFlange Size -05 50 mm, 2” -08 80 mm, 3” -10 100 mm, 4”Flange rating A1 ANSI class 150-2500 (PSI) D1 DIN PN10 - 400 (bar) flangeFlange Material SS Stainless Steel AISI-316 LDiaphragm Material SS Stainless Steel AISI 316-L HC Hastelloy C276 (NACE) ET Coating ECTFE FE Coating FEP PF Coating PFA PT Coating PTFE PV Coating PVDF AG Electro-plated Silver 10 um AU Electro-plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 -40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Silicon Oil -F4 -15 to 205°C NEOBee M20 FDA approved fill fluid -F5 - 40 to 399°C Silicon Oil -F6 - 80 to 100°C Fluorinated Oil -F7 - 10 to 315°C Silicon Oil -F8 - 40 to 315°C Silicon Oil -F9 - 40 to 120°C Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured with PVC protection sleeveCapillary Length 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /FRxx See page 3 for flushing rings /NACE MR0175-2003 (select HC)
10
Cell type seal with side capillary
Cell type seal mounted between process flanges with flushing ring
GS 06P01Y01-E-E
GS 06P01Y01-E-E
11
Technical specification model BC
Flanged connectionASME 2” 3” 3” / 4”DIN DN50 DN80 DN80 / 100Diaphragm size in mm 57 72 89Max. process pressure in bar at 20 °C 414 414 414Max. capillary length in meter 15 15 15Min. pressure range for PI in bar 0.6 0.5 0.5Min. span for GP & AP in mbar 600 200 80Min. span for DP in mbar 100 20 10
Process connection Standard OptionsASME B 16.5 1” / 11/2 / 2” / 3” / 4” Other sizes acc ASME 150 … 2500# RF FF, groove, RJ, RTJ Ra 3.2…6.3 µm Other finishesDIN 2501 (EN 1092-1 ) DN25 / 40 / 50 / 80 / 100 Other sizes acc DIN PN10 … 400 bar Form D-Din2526, (Form B1) Other types and finishesJIS On request
Wetted parts Standard OptionsCell AISI316 (L) Custom designDiaphragm (weld in process) AISI316 (L)
Instrument connection Standard OptionsCapillary tubing Side entry
Features Standard OptionsCapillary tubing AISI316 PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsFlushing rings For all DIN, ANSI flangesSupport handle On all flanges above 600#Support pipe Heavy duty pipe on capillaryBAsecal calculation All transmitters with sealsCalibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange Flange GP AP DP 44 mm DN50 2” 1250 1250 300 57 mm DN50 2” 600 600 100 72 mm DN80 3” 200 200 20 89 mm DN80 3” 80 80 10 89 mm DN100 4” 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 44 mm DN50 2” 0.20 1.24 2.28 1.90 4.90 10.3 57 mm DN50 2” 0.15 0.66 0.63 1.70 2.65 3.9 72 mm DN80 3” 0.10 0.24 0.20 0.55 0.95 1.2 89 mm DN80 3” 0.04 0.09 0.08 0.19 0.39 0.4 89 mm DN100 4” 0.04 0.09 0.08 0.19 0.39 0.4
Temperature effect is per +10 °C and measured from 20 °C.
12
Diaphragm seal BRC flush diaphragm�� cell type
Model and Suffix codes DFS-BRC
Model Suffixcode DescriptionDFS-BRC Diaphragm Seal - cell type�� Raised FaceFlange Size -05 50 mm, 2” -08 80 mm, 3” -10 100 mm, 4”Flange rating A1 ANSI class 150 - 2500 (PSI) D1 DIN PN10 - 400 (bar) flangeFlange Material SS Stainless Steel AISI-316 LDiaphragm Material / SS Stainless Steel AISI-316 L Coatings HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI TitaniumFill Fluid -F1 -10 to 350°C Silicon Oil -F2 -40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Silicon Oil -F4 -15 to 205°C NEOBee M20 FDA approved fill fluid -F5 - 40 to 399°C Silicon Oil -F6 - 80 to 100°C Fluorinated Oil -F7 - 10 to 315°C Silicon Oil -F8 - 40 to 315°C Silicon Oil -F9 - 40 to 120°C Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured with PVC protection sleeveCapillary Length 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /FRxx See page 3 for flushing rings /NACE MR0175-2003 (select HC)
Cell type seal with side capillary
Cell type seal mounted between process flanges with flushing ring
GS 06P01Y01-E-E
GS 06P01Y01-E-E
13
Technical specification model BRC
Flanged connectionASME 2” 3” 3” / 4”DIN DN�0 DN80 DN80 / 100Diaphragm size in mm 57 72 89Max. process pressure in bar at 20 °C 414 414 414Max. capillary length in meter 15 15 15Min. pressure range for PI in bar 0.6 0.5 0.5Min. span for GP & AP in mbar 600 200 80Min. span for DP in mbar 100 20 10
Process connection Standard OptionsASME B 16.5 1” / 11/2 / 2” / 3” / 4” Other sizes acc ASME 150 … 2500# RF Other facing Factory standard face finishDIN 2501 (EN 1092-1 ) DN25 / 40 / 50 / 80 / 100 Other sizes acc DIN PN10 … 400 bar Form D-Din2526, (Form B1) Other types and finishesJIS On request
Wetted parts Standard OptionsCell AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm Hastelloy C276 Tantalum, Silver, AISI316L
Instrument connection Standard OptionsCapillary tubing Side entry
Features Standard OptionsCapillary tubing AISI316Armoring AISI304 PVC sleeve blackDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsFlushing rings For all DIN, ANSI flangesSupport handle On all flanges above 600#Support pipe Heavy duty pipe on capillaryBAsecal calculation All transmitters with sealsCalibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange Flange GP AP DP 44 mm DN50 2” 1250 1250 300 57 mm DN50 2” 600 600 100 72 mm DN80 3” 200 200 20 89 mm DN80 3” 80 80 10 89 mm DN100 4” 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 44 mm DN50 2” 0.20 1.24 2.28 1.90 4.90 10.3 57 mm DN50 2” 0.15 0.66 0.63 1.70 2.65 3.9 72 mm DN80 3” 0.10 0.24 0.20 0.55 0.95 1.2 89 mm DN80 3” 0.04 0.09 0.08 0.19 0.39 0.4 89 mm DN100 4” 0.04 0.09 0.08 0.19 0.39 0.4
Temperature effect is per +10 °C and measured from 20 °C.
14
Model Suffixcode DescriptionDFS-EXT Diaphragm Seal - Blind flange�� Raised Face Covered
Flange Size -05 50 mm, 2” -08 80 mm, 3” -10 100 mm, 4”Flange rating A1 ANSI class 150 (PSI) A2 ANSI class 300 (PSI) A4 ANSI class 600 (PSI) D1 DIN PN10 (bar) flange D3 DIN PN25 (bar) flange D4 DIN PN40 (bar) flangeFlange Material SS Stainless Steel AISI-316 LDiaphragm -050 Extension length, 50 mmExtention Length -100 Extension length, 100 mm -150 Extension length, 150 mm -200 Extension length, 200 mm -250 Extension length, 250 mmExtension Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI TitaniumDiaphragm Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI TitaniumFill Fluid -F1 -10 to 350°C Silicon Oil -F2 - 40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Silicon Oil -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluid -F5 -40 to 399°C Silicon Oil -F6 -80 to 100°C Fluorinated Oil -F7 -10 to 315°C Silicon Oil -F8 -40 to 315°C Silicon Oil -F9 - 40 to 120ºC Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded constr. recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /NACE MR0175-2003 (select HC)
“H” to be specified capillary execution
“H” to be specified threaded execution
Diaphragm seal EXT extended diaphragm�� flanged type
ASME DIN d� size DN (mm) 2” 50 48 3” 80 76 4” 100 93
GS 06P01Y01-E-E
GS 06P01Y01-E-E
15
Technical specification model EXT
Flanged connectionASME 2” 3” 3” / 4”DIN DN�0 DN80 DN100Diaphragm size in mm 44 72 89Max. process pressure in bar at 20 °C 414 414 414Max. capillary length in meter 10 15 15Min. pressure range for PI in bar 1.6 0.5 0.5Min. span for GP & AP in mbar 1250 200 80Min. span for DP in mbar 300 20 10
Process connection Standard OptionsASME B 16.5 2” / 3” / 4” Other sizes acc ASME 150 / 300 / 600# > 600# RF FF, groove, RJ, RTJ Ra 3.2…6.3 µm Other finishesDIN 2501 (EN 1092-1 ) DN50 / 80 / 100 Other sizes acc DIN PN10 / 25 / 40 > 40 bar Form D-Din2526, (Form B1) Other types and finishesJIS On request
Wetted parts Standard OptionsFlange with extension AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm (weld in process) AISI316 (L) Tantalum, Titanium Inconel600 Hastelloy C276, Silver
Instrument connection Standard OptionsCapillary Top entry Side entry, threaded
Features Standard OptionsCapillary tubing AISI316Armoring AISI304 PVC sleeve blackDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instruments except PIFull welded construction All instrumentsLining on extension TantalumSupport handle On all flanges above 600#Support pipe Heavy duty pipe on capillaryBAsecal calculation All transmitters with sealsCalibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange Flange GP AP DP 25 mm DN32 1” n.a n.a n.a. 32 mm DN40 1 1/2” n.a n.a n.a. 44 mm DN50 2” 1250 1250 300 72 mm DN80 3” 200 200 20 89 mm DN100 4” 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 25 mm DN32 1” n.a. n.a. n.a. n.a. n.a. n.a. 32 mm DN40 1 1/2” n.a. n.a. n.a. n.a. n.a. n.a. 44 mm DN50 2” 0.20 1.24 2.28 1.90 4.90 10.35 72 mm DN80 3” 0.10 0.24 0.20 0.55 0.95 1.2 89 mm DN100 4” 0.04 0.09 0.08 0.19 0.39 0.4
GS 06P01Y01-E-E
16
Model Suffixcode DescriptionDFS-USF Diaphragm Seal - Universal Seal FlangedFlange Size -01 15mm, 1/2” -02 25 mm, 1” -04 40 mm, 1-1/2”Flange rating A1 ANSI class 150 (PSI) A2 ANSI class 300 (PSI) A4 ANSI class 600 (PSI) D4 DIN2501 PN40 (bar) flangeProcess SS Stainless Steel AISI 316 L Connection HB Hastelloy B2Material HC Hastelloy C276 I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TI TitaniumDiaphragm Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI Titanium ET Coating ETFE FE Coating FEP PA Coating PFA PT Coating PTFE PV Coating PVDF AG Electro plated Silver 10um AU Electro plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 - 40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Standard fill fluidl -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluid -F5 -40 to 399°C Silicon Oil -F6 -80 to 100°C Fluorinated Oil -F7 -10 to 315°C Silicon Oil -F8 -40 to 315°C Silicon Oil -F9 - 40 to 120°C Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 02 2 m capillary02 2 m capillary 03 3 m capillary 03 3 m capillary03 3 m capillary 04 4 m capillary 04 4 m capillary04 4 m capillary 05 5 m capillary 05 5 m capillary05 5 m capillary 06 6 m capillary 06 6 m capillary06 6 m capillary 07 7 m capillary 07 7 m capillary07 7 m capillary 08 8 m capillary 08 8 m capillary08 8 m capillary 09 9 m capillary 09 9 m capillary09 9 m capillary 10 10 m capillary 10 10 m capillary10 10 m capillary 11 11 m capillary 11 11 m capillary11 11 m capillary 12 12 m capillary 12 12 m capillary12 12 m capillary 13 13 m capillary 13 13 m capillary13 13 m capillary 14 14 m capillary 14 14 m capillary14 14 m capillary 15 15 m capillary 15 15 m capillary15 15 m capillary ZZ User-defined ZZ User-definedZZ User-definedOptions /FW Full welded construction recommended
for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /NACE MR0175-2003 (select HC)
Capillary execution
Upper parts are interchangeable with the full range of process flange connections
Process flanges have threaded holes for stud end bolt mounting
Diaphragm seal USF internal diaphragm�� flanged type
Technical specification model USF
Flanged connectionASME 1/2 3/4” 1” 1 1/4” 1 1/2”DIN DN1� DN20 DN2� DN32 DN40Diaphragm size in mm 51 51 51 51 51Max. process pressure in bar at 20 °C 300 300 300 300 300Max. capillary length in meter 15 15 15 15 15Min. pressure range for PI in bar 1.0 1.0 1.0 1.0 1.0Min. span for GP & AP in mbar 800 800 800 800 800Min. span for DP in mbar 200 200 200 200 200
Process connection Standard OptionsASME B 16.5 1/2” / 3/4” 1” / 1 1/4” / 1 1/2” 2” and other sizes acc ASME 150 / 300 / 600# > 600# RF FF,groove,RJ,RTJ Ra 3.2…6.3 µm Other finishesDIN 2501 DN15 / 20 / 25 / 32 / 40 NW50 and other sizes acc DIN PN10 / 25 / 40 > 40 barDIN EN 1092-1 Form D (DIN2526) Other types and finishesJIS On request
Wetted parts Standard OptionsUpperflange AISI316 (L) Exotic materialsLowerflange AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm AISI316L Tantalum, Titanium Inconel 600 Hastelloy-C276, Silver
Instrument connection Standard OptionsCapillary tubing Top entryThreaded 1/2” BSP 1/4” NPT / 1/2” NPT / 1/4”BSP
Process connection Standard OptionsCapillary tubing AISI316Armoring AISI304 PVC sleeve blackDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instruments except PIFull welded construction All instrumentsFlushing connection 1 or 2 ( with 1/4”npt plugs)Calibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange GP AP DP 51 mm All sizes 800 800 200
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 51 mm All sizes 0.175 0.96 0.77 2.35 3.95 4.70
Temperature effect is per +10 °C and measured from 20 °C.
Bolting
4 x A-270 4 x st 8.8 - max 150 bar *
3/8”UNF max 125 bar at 20 °C
8 x A-270 - max 250 bar * 8 x st 8.8 - max 300 bar ** max pressure for bolts always at 20 °C
GS 06P01Y01-E-E
17
GS 06P01Y01-E-E
18
Model Suffixcode DescriptionDFS-USLF Diaphragm Seal - Universal Seal FlangedFlange Size -01 15mm, 1/2” -02 25 mm, 1” -04 40 mm, 1-1/2” -05 50 mm, 2”Flange rating A1 ANSI class 150 (PSI) A2 ANSI class 300 (PSI) A4 ANSI class 600 (PSI) D4 DIN2501 PN40 (bar) flangeProcess SS Stainless Steel AISI 316 LConnection HB Hastelloy B2Material HC Hastelloy C276 I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TI TitaniumDiaphragm Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI Titanium ET Coating ETFE FE Coating FEP PA Coating PFA PT Coating PTFE PV Coating PVDF AG Electro plated Silver 10um AU Electro plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 - 40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Standard fill fluid -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluid -F5 -40 to 399°C Silicon Oil -F6 -80 to 100°C Fluorinated Oil -F7 -10 to 315°C Silicon Oil -F8 -40 to 315°C Silicon Oil -F9 - 40 to 120ºC Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /NACE MR0175-2003 (select HC)
Capillary execution
Upper parts are interchangeable with the full range of process flange connections
Process flanges have threaded holes for stud end bolt mounting
Diaphragm seal USLF internal diaphragm�� low pressure flanged type
Technical specification model USLF
Flanged connectionASME 1” 11/2” / 2” 2”DIN DN32 DN40 DN�0Diaphragm size in mm 89 89 89Max. process pressure in bar at 20 °C 100 100 100Max. capillary length in meter 15 15 15Min. pressure range for PI in bar 0.6 0.6 0.6Min. span for GP & AP in mbar 80 80 80Min. span for DP in mbar 10 10 10
Process connection Standard OptionsASME B 16.5 1/2” / 3/4” 1” / 1 1/4” / 1 1/2” 2” and other sizes acc ASME 150 / 300 / 600# > 600# RF FF,groove,RJ,RTJ Ra 3.2…6.3 µm Other finishesDIN 2501 DN15 / 20 / 25 / 32 / 40 NW50 and other sizes acc DINDIN EN 1092-1 PN10 / 25 / 40 > 40 bar Form D (DIN2526) Other types and finishesJIS On request
Wetted parts Standard OptionsUpperflange AISI316 (L) Exotic materialsLowerflange AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm AISI316L Tantalum, Titanium Inconel 600 Hastelloy-C276, Silver
Instrument connection Standard OptionsCapillary tubing Top entryThreaded 1/2” BSP 1/4” NPT / 1/2” NPT / 1/4”BSP
Instrument connection Standard OptionsCapillary tubing AISI316Armoring AISI304 PVC sleeve blackDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsFlushing connection 1 or 2 ( with 1/4”npt plugs)Calibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Flange GP AP DP 89 mm All sizes 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Flange DP Seal Cap / mtr GP/AP Seal Cap / mtr 89 mm All sizes 0.04 0.09 0.08 0.19 0.39 0.40Temperature effect is per +10 °C and measured from 20 °C.
Bolting 8 x A-270M.W.P. 100 bar at 20 °C
GS 06P01Y01-E-E
19
GS 06P01Y01-E-E
20
Model Suffixcode DescriptionDFS-UST Diaphragm Seal - Universal Seal ThreadedThread Size -T1 1/4” Thread -T2 1/2” Thread -T3 3/4” Thread -T4 1” ThreadThread Form NF NPT Female Thread Form NM NPT Male Thread Form BF BSP Female Thread Form BM BSP Male Thread FormProcess Conn.n SS Stainless Steel AISI 316 L Material HB Hastelloy B2 HC Hastelloy C276 I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TI TitaniumDiaphragm Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI Titanium ET Coating ETFE FE Coating FEP PF Coating PFA PT Coating PTFE PV Coating PVDF AG Electro plated Silver 10um AU Electro plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 - 40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Standard fill fluid -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluid -F5 -40 to 399°C Silicon Oil -F6 -80 to 100°C Fluorinated Oil -F7 -10 to 315°C Silicon Oil -F8 -40 to 315°C Silicon Oil -F9 - 40 to 120ºC Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /NACE MR0175-2003 (select HC)
Threaded female process connection
Threaded male process connection
Diaphragm seal UST internal diaphragm�� threaded type
Technical specification model UST
Threaded connectionNPT (male or female) 1/2” 3/4” 1”BSP (male or female)Diaphragm size in mm 51 51 51Max. process pressure in bar at 20 °C 300 300 300 8 bolts st 8.8Max. capillary length in meter 15 15 15Min. pressure range for PI in bar 1.0 1.0 1.0Min. span for GP & AP in mbar 800 800 800Min. span for DP in mbar 200 200 200
Process connection Standard Options 1/2” / 3/4” / 1” Other sizesThreaded according NPT / BSP mm / SAE and othersANSI / DIN / EN / JIS Male / femaleBolting 4 x st 8.8 - max 150 bar *3/8”UNF 4 x A-270 8 x A-270 - max 250 bar * max 125 bar at 20 °C 8 x st 8.8 - max 300 bar ** max pressures for bolts always at 20 °C
Wetted parts Standard OptionsUpperflange AISI316 (L) Exotic materialsLowerflange AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm AISI316L Tantalum, Titanium Inconel 600 Hastelloy-C276, Silver
Instrument connection Standard OptionsCapillary tubing Top entryThreaded 1/2” BSP 1/4” NPT / 1/2” NPT / 1/4”BSP
Features Standard OptionsCapillary tubing AISI316 PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instruments except PIFully welded construction All instrumentsFlushing connection 1 or 2 ( with 1/4” npt plugs)Calibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Thread GP AP DP 51 mm 1/2” male Fem 800 800 200 51 mm 3/4” male Fem 800 800 200 51 mm 1” male Fem 800 800 200
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Thread DP Seal Cap / mtr GP/AP Seal Cap / mtr 51 mm 1/2” male Fem 0.175 0.96 0.77 2.35 3.95 4.70 51 mm 3/4” male Fem 0.175 0.96 0.77 2.35 3.95 4.70 51 mm 1” male Fem 0.175 0.96 0.77 2.35 3.95 4.70
Temperature effect is per +10 °C and measured from 20 °C.
GS 06P01Y01-E-E
21
GS 06P01Y01-E-E
22
Model Suffixcode DescriptionDFS-USLT Diaphragm Seal - Universal Seal ThreadedThread Size -T1 1/4” Thread -T2 1/2” Thread -T3 3/4” Thread -T4 1” ThreadThread Form NF NPT Female Thread Form NM NPT Male Thread Form BF BSP Female Thread Form BM BSP Male Thread FormProcess SS Stainless Steel AISI 316 LConnection HB Hastelloy B2 Material HC Hastelloy C276 I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TI TitaniumDiaphragm Material SS Stainless Steel AISI 316 L HB Hastelloy B2 HC Hastelloy C276 (NACE) I6 Inconel 600 M4 Monel 400 N2 Nickel 200 TA Tantalum TI Titanium ET Coating ETFE FE Coating FEP PA Coating PFA PT Coating PTFE PV Coating PVDF AG Electro plated Silver 10um AU Electro plated Gold 40 umFill Fluid -F1 -10 to 350°C Silicon Oil -F2 - 40 to 250°C Flurinated Oil for Oxygen service -F3 -40 to 200°C Standard fill fluid -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluid -F5 - 40 to 399°C Silicon Oil -F6 - 80 to 100°C Fluorinated Oil -F7 - 10 to 315°C Silicon Oil -F8 - 40 to 315°C Silicon Oil -F9 - 40 to 120ºC Silicon Oil (fast response)Capillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate /NACE MR0175-2003 (select HC)
Threaded female process connection
Threaded male process connection
Diaphragm seal USLT internal diaphragm�� low pressure threaded type
Technical specification model USLT
Threaded connectionNPT (male or female) 1/2” 3/4” 1”BSP (male or female)Diaphragm size in mm 89 89 89Max. process pressure in bar at 20 °C 100 100 100 8 bolts st A-270Max. capillary length in meter 15 15 15Min. pressure range for PI in bar 0.6 0.6 0.6Min. span for GP & AP in mbar 80 80 80Min. span for DP in mbar 10 10 10
Process connection Standard Options 1/2” / 3/4” / 1” Other sizesThreaded according NPT / BSP mm / SAE and othersANSI / DIN / EN / JIS Male / femaleBoltingM10 10 x A-270 max 100 bar at 20 °C
Wetted parts Standard OptionsUpperflange AISI316 (L) Exotic materialsLowerflange AISI316 (L) Exotic materials Hastelloy B2, Monel,Diaphragm AISI316L Tantalum, Titanium Inconel 600 Hastelloy-C276, Silver
Instrument connection Standard OptionsCapillary tubing Top entryThreaded 1/2” BSP 1/4” NPT / 1/2” NPT / 1/4”BSP
Process connection Standard OptionsCapillary tubing AISI316 PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteDiaphragm AISI316L On requestTemperature reducer All instruments except DPTemperature compensator All instruments except PIFully welded construction All instrumentsFlushing connection 1 or 2 ( with 1/4” npt plugs)Calibration on process conditions All instrumentsHydrogen applications Gold coating All AISI316 diaphragmsSpecial coatings PTFE, FEP, ECTFE, PFA
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Thread GP AP DP 89 mm 1/2” male Fem 80 80 10 89 mm 3/4” male Fem 80 80 10 89 mm 1” male Fem 80 80 10
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar Temp. effect in mbar For process connections For DP transmitters For GP /AP transmitters Diaphragm Thread DP Seal Cap / mtr GP/AP Seal Cap / mtr 89 mm 1/2” male Fem 0.04 0.09 0.08 0.19 0.39 0.40 89 mm 3/4” male Fem 0.04 0.09 0.08 0.19 0.39 0.40 89 mm 1” male Fem 0.04 0.09 0.08 0.19 0.39 0.40
Temperature effect is per +10 °C and measured from 20 °C.
GS 06P01Y01-E-E
23
24
GS 06P01Y01-E-E
Model Suffixcode DescriptionDFS-PS Flush Diaphragm Seal threaded PN600 Thread Size -T4 1” Thread -T5 1-1/2” Thread -T6 2” ThreadThread form NM NPT Male Thread Form BM BSP Male Thread FormProcess Connection SS Stainless Steel AISI 316 LDiaphragm Material SS Stainless Steel AISI 316 LFill Fluid -F3 -40 to 200°C Standard fill fluidCapillary Size / Type NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded(No Capillary) Options /FW Full welded construction recommended for vacuum service /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate
Model PS Dimensions in MM G2 PN dD L d HX 1” BSP 600 25 21 39 41 1 1/2” BSP 600 32 30 60 54 2” BSP 600 44 35 70 60 1” NPT 600 25 23 39 41 1 1/2” NPT 600 32 23 60 54 2” NPT 600 44 37 70 60
HX
L
dDG2d
Seal PSPT
Diaphragm seal PS�� Flush Diaphragm Seal Threaded PN600
25
GS 06P01Y01-E-E
Technical specification model PS
Threaded connectionNPT (male or female) PS 1” 11/2” 2”BSP (male or female) PS 1” 11/2” 2”Diaphragm size in mm 25 32 44Max. process pressure in bar at 20 °C 600 600 600Max. capillary length in meter 3 6 10
Process connection Standard OptionsModel PS 1” / 11/2”/ 2” NPT/BSP
Wetted parts Standard OptionsProcess Connection AISI316 (L)Diaphragm AISI316L
Instrument connection Standard OptionsThreaded PS Welded
Features Standard OptionsCapillary tubing AISI316 PVC sleeve black Armoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteFilling fluid BSO22 On requestDiaphragm AISI316L On requestTemperature reducer All instruments except DPFull welded construction All instrumentsCalibration on process connections All instruments
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Thread GP 23 mm 1” male PS 4000 32 mm 11/2” male PS 2500 44 mm 2” male PS 1250
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar For process connections For GP transmitters Diaphragm Thread Flange GP/AP Seal Cap / mtr 25 mm 1” male PS 0.55 0.95 1.2 32 mm 11/2” male PS 0.19 0.39 0.4 44 mm 2” male PS 0.19 0.39 0.4
Temperature effect is per +10 °C and measured from 20 °C.
Model Suffixcode DescriptionDFS-ILS Diaphragm Seal - Inline SanitaryProcess -D3 Inline Sanitary Seal DIN 25 (11851) Connection -D4 Inline Sanitary Seal DIN 32 (11851) -D5 Inline Sanitary Seal DIN 40 (11851) -D6 Inline Sanitary Seal DIN 50 (11851) -D7 Inline Sanitary Seal DIN 65 (11851) -D8 Inline Sanitary Seal DIN 80 (11851) -D10 Inline Sanitary Seal DIN 100 (11851) -A5 Inline Sanitary Seal 1-1/2” ISO 2852 -A6 Inline Sanitary Seal 2” ISO 2852 -A8 Inline Sanitary Seal 3” ISO 2852Process Conn. Matl. SS Stainless Steel AISI 316 L Diaphragm Material SS Stainless Steel AISI 316 L Fill Fluid -F4 - 15 to 205°C NEOBee M20 FDA approved fill fluidCapillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured + PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded (No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-defined Options /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate
GS 06P01Y01-E-E
26
IDF per ISO 2852Clamp per ISO 2852
DIN 11851 / DIN 32676
Diaphragm seal ILS-S in-line diaphragm�� sanitary type
Inline diaphragm seals for pipes as per DIN 118�0DIN 118�1 / DIN 32676
DN Øi S-32676 S-11851 L 25 26 50.5 52 x 1/6” 110 32 32 50.5 58 x 1/6” 110 40 38 50.5 65 x 1/6” 110 50 50 64 78 x 1/6” 110 65 66 91 95 x 1/6” 110 80 81 106 110 x 1/4” 60 100 100 119 130 x 1/4” 60
Inline diaphragm seals for pipes as per O.D.tubing “inch” BS 482� part1Clamp ISO 28�2 / IDF ISO 28�3
S-2852 S-2853 1” 22.2 50.5 37 x 3.175 110 1 1/2” 34.8 50.5 50.5 x 3.175 110 2” 47.8 64 64 x 3.175 110 2 1/2” 60.3 77.5 77.5 x 3.175 110 3” 72.9 91 91 x 3.175 60 4” 97.6 119 118 x 3.175 60
GS 06P01Y01-E-E
27
Technical specification model ILS-S
Process connection ISO28�2 / �3 1” – 2 ” 2 1/2” – 4”DIN118�1 / 32676 DN2�-�0 DN6�-100Max. process pressure in bar at 20 °CDIN11851 / 32676 40 25ISO 2853 40 (1”-1 1/2” ) 25 ( 2”-4” )ISO 2852 16 10Max. capillary length in meter 6 10 … 15Min. pressure range for PI in bar 2.5 1.6 … 0.6Min. span for GP & AP in bar 10 1.6 … 0.6Min. span for DP in bar 0.8 … 0.25
Process connection Standard OptionsDIN 11851 maleBoth sides DN25 / 32 / 40 / 50 / 65 / 80 / 100ISO 2852 / DIN 32676Clamp fixing 1” / 1 1/2” / 2” / 2 1/2” / 3” / 4”
Wetted parts Standard OptionsProcess connection AISI316Diaphragm AISI316 Tantalum, Monel 400, Hastelloy-C276,
Instrument connection Standard OptionsCapillary tubing Top entryThreaded 1/2 BSP female Other sizes
Features Standard OptionsCapillary tubing AISI316 PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteTemperature reducer All instruments except DPTemperature compensator All instrumentsFull welded construction All instrumentsSupport pipe Heavy duty pipe on capillaryCalibration on process conditions All instrumentsSpecial materials / coatings Acc. Basle standard
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in bar For process connections For transmitters Size Size GP DN25-40 1” - 1 1/2” 10 DN50 2” - 2 1/2” 1.6 DN80-100 3” - 4” 0.5
Temperature effect on transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar For process connections For GP transmitters Size Size GP/AP Seal Cap / mtr DN25-40 1” - 1 1/2” 20 35 140 DN50 2” - 2 1/2” 5 15 30 DN80-100 3” - 4” 1 5 25Temperature effect is per +10 °C and measured from 20 °C.
Model Suffixcode DescriptionDFS-SA Diaphragm Seal - SanitaryProcess -D5 Sanitary Seal DIN 40 Connection -D6 Sanitary Seal DIN 50 -D8 Sanitary Seal DIN 80 -S5 Sanitary Seal 1-1/2” SMS 1145 -S6 Sanitary Seal 2” SMS 1145 -S8 Sanitary Seal 3” SMS 1145 -A5 Sanitary Seal 1-1/2” APV RTJ -A6 Sanitary Seal 2” APV RTJ -A8 Sanitary Seal 3” APV RTJ -I5 Sanitary Seal 1-1/2” ISO 2853 IDF -I6 Sanitary Seal 2” ISO 2853 IDF -I8 Sanitary Seal 3” ISO 2853 IDF -T5 Sanitary Seal 1-1/2” Tri-Clamp, ISO 2852 -T6 Sanitary Seal 2” Tri-Clamp, ISO 2852 -T8 Sanitary Seal 3” Tri-Clamp, ISO 2852Process Conn. Mat. SS Stainless Steel AISI 316 LDiaphragm Material SS Stainless Steel AISI 316 LFill Fluid -F4 - 15 to 205°C NEOBee M20
FDA approved fill fluidCapillary Size / Type C1 Stainless Steel Armoured C2 Stainless Steel Armoured
with PVC protection sleeve NN Direct coupled / Welded (No Capillary)Capillary Length NN Direct coupled / Welded(No Capillary) 01 1 m capillary 1A 1,5 m capillary 02 2 m capillary 03 3 m capillary 04 4 m capillary 05 5 m capillary 06 6 m capillary 07 7 m capillary 08 8 m capillary 09 9 m capillary 10 10 m capillary 11 11 m capillary 12 12 m capillary 13 13 m capillary 14 14 m capillary 15 15 m capillary ZZ User-definedOptions /FW Full welded construction recommended for vacuum service /N5 Low volume cover /K1 Degreasing Treatment /K2 Degreasing Treatment (applicable F2 fill) /XM11 Without 3.1 Material Certificate
GS 06P01Y01-E-E
28
Diaphragm seal SAF�� SAM�� SAT flush diaphragm�� sanitary type
GS 06P01Y01-E-E
29
Technical specification model SAF�� SAM��SAT
Threaded connectionDIN118�1 (male or female) DN40 DN�0 DN80SMS 114� (male or female) 1 1/2” 2” 3”IDF (male or female) 1 1/2” 2” 3”APV-RTJ (male or female) 1 1/2” 2” 3”SAT ISO 2852 1 1/2” 2” 3”Diaphragm size in mm 32 44 72Max. process pressure in bar at 20 °CDIN118�1 40 25 25SMS 114� 40 25 25IDF 28�3 40 40 25APV RTJ 40 25 25SAT ISO 28�2 40 40 25Max. capillary length in meter 6 10 15Min. pressure range for PI in bar 2.5 1.6 0.6Min. span for GP & AP in mbar 4000 1250 200Min. span for DP in mbar n.a. 300 20
Process connection Standard OptionsSAF acc DIN11851 DN40 / 50 / 80 DN25 / 32 and male connections (SAM)
SAF acc SMS 1145 1 1/2” / 2” / 3” Male connections (SAM)SAF acc APV-RTJ 1 1/2” / 2” / 3” Male connections (SAM)SAF acc ISO 2853 IDF 1 1/2” / 2” / 3” Male connections (SAM)SAT acc ISO 2852 1 1/2” / 2” / 3” 3/4” / 2 1/2”, and clamp units
Wetted parts Standard OptionsProcess connection AISI316(L)Diaphragm AISI316L Hastelloy B2, Monel, Hastelloy-C276,Upperbody AISI316 (L)
Instrument connection Standard OptionsThreaded 1/2 BSP female SpecialCapillary Top entry
Features Standard OptionsCapillary tubing AISI316 PVC sleeve blackArmoring AISI304 Polyolefin sleeve black Polyolefin sleeve whiteTemperature reducer All instruments except DPFull welded construction All instrumentsCalibration on process conditions All instrumentsMDS leaking diaphragm detection system All instruments
Minimum ranges for gauges and transmitters per diaphragm Diaphragm diameters dD Min. span in mbar For process connections For transmitters Diaphragm Thread GP AP DP 32 mm 1 1/2” / DN40 2000 2000 n.a. 44 mm 2” / DN50 1250 1250 300 72 mm 3” / DN80 200 200 20
Temperature effect for transmitter�� capillary and seal Diaphragm diameters dD Temp. effect in mbar per 10ºC For process connections On transmitters Diaphragm Thread GP AP DP Seal Cap / mtr 32 mm 1 1/2” / DN40 20 20 - 17 17 44 mm 2” / DN50 5 5 - 5 10,35 72 mm 3” / DN80 0,05 1,24 2,28 72 mm 3” / DN80 0,6 0,6 1 1,2 72 mm 3” / DN80 0,05 0,24 0,2
Model Size DN P rating dD D T hFemaleSAF DIN11851 25 40 20 63 Rd52 x 1/6 21SAF DIN11851 32 40 25 70 Rd58 x 1/6 21SAF DIN11851 40 40 32 78 Rd65 x 1/6 21SAF DIN11851 50 25 44 92 Rd78 x 1/6 22SAF DIN11851 80 25 72 127 Rd110 x 1/2 30SAF SMS 1 1/2” 40 32 74 Rd60 x 1/6 25SAF SMS 2” 40 44 84 Rd70 x 1/6 26SAF IDF 1 1/2” 40 32 64 1 1/2” IDF 30SAF IDF 2” 40 44 79 2” IDF 30SAF APV-RTJ 1 1/2” 40 32 72 2 5/16 x 8” 22SAF APV-RTJ 2” 40 44 86 2 7/8 x 6” 22MaleSAM DIN11851 40 40 32 Rd65 x 1/6
SAM DIN11851 50 25 44 Rd78 x 1/6
SAM SMS 1 1/2” 40 32 Rd60 x 1/6
SAM SMS 2” 40 44 Rd70 x 1/6
SAM IDF 1 1/2” 40 32 1 1/2” IDFSAM IDF 2” 40 44 2” IDFSAM APV-RTJ 1 1/2” 40 32 2 5/16 x 8”SAM APV-RTJ 2” 40 44 2 7/8 x 6”
Model Size DN P rating dD DSAT 1 1/2” 40 32 50.5SAT 2” 40 44 64SAT 2 1/2” 25 52 77.5SAT 3” 25 72 91
utions with threaded or capillary instrument connection and with male or female process connections.
30
GS 06P01Y01-E-E
GS 06P01Y01-E-ESubject to change without notice Printed in The Netherlands, 03-806 (A) ICopyright©
YOKOGAWAYOKOGAWA EUROPE B.V.Databankweg 203821 AL AMERSFOORTThe NetherlandsTel. +31-33-4641 611Fax +31-33-4641 610www.yokogawa.com/eu
Yokogawa has an extensive sales and distribution network. Please refer to the European website (www.yokogawa.com/eu) to contact your nearest representative.
Top Related