Powered by
Automatic Gen-Set Controllerswith Remote Control & Visualisation ................................. 3
Enhanced Automatic Gen-Set Controllerswith Transfer Switching ....................................................... 7
Automatic Gen-Set Controllerswith Transfer Switching .................................................... 15
Auto Start Gen-Set Protection & Controllers .................. 18
Manual Key Start & Engine Protectionwith Key Switch ................................................................. 24
Automatic Transfer Switch ................................................ 25
Battery Charger .................................................................. 27
About EMKO ..................................................................... 28
Automatic Gen-Set Controllerswith Transfer Switching
2
Comparison Table
Model EAOM-19 EAOM-9 EAOM-9F EAOM-210.FD EAOM-210.FL Messenger Messenger.ProEAOM-210.FDJ** EAOM-210.FLJ**
Dimensions (mm) 72x72 96x96 144x204 144x204 144x204 144x204 144x204
Display LED LED LED LED LCD (Graphic) LCD (Graphic) LCD (Graphic)
Generator L1/N L1/N L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NVoltage L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/NMeasurement L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N
Mains Voltage L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NMeasurement L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N
L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N
Generator No No No KVAh, kWh, kVA, KVAh, kWh, kVA, KVAh, kWh, kVA, KVAh, kWh, kVA,Power kW, kVAr, kVarh kW, kVAr, kVarh kW, kVAr, kVarh kW, kVAr, kVarhMeasurement
Load Current No No No Yes Yes Yes YesMeasurement
Earth Current No No No Yes Yes Yes YesMeasurement
Outputs Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn,Mains and Mains and Mains and Mains Open and Mains Open and Mains Open and Mains Open andGenerator Generator Generator Close, Generator Close, Generator Close, Generator Close, GeneratorContactor Contactor Contactor Open and Close Open and Close Open and Close Open and Close
Configurable No 1 User 1 User 4 User 4 User, 4 User, 4 User,Outputs Configurable Configurable Configurable Configurable Configurable Configurable
+8 conf.w/expansion
board
Configurable 2 User 2 User 2 User 6 User 6 User, 6 User, 6 User,Inputs Configurable Configurable Configurable Configurable Configurable Configurable Configurable
+8 conf.w/expansion
board
Outputs Type Relay Relay Transistor Relay Relay Relay Relay
Analogue No No No Oil Pressure Oil Pressure Oil Pressure Oil PressureResistive Fuel Level Fuel Level Fuel Level Fuel LevelSender Inputs Temperature Temperature Temperature Temperature
Speed Sensing From From From From From From FromAlternator Alternator Alternator Alternator Alternator Alternator Alternator
signal signal signal signal signal signal signalor magnetic or magnetic or magnetic or magnetic or magnetic or magnetic
pickup pickup pickup pickup pickup pickup
Two Level Operator & Operator & Operator & Operator & Operator & Operator & Operator &Passwords Technician Technician Technician Technician Technician Technician Technician
Timer Timer Timer Timer Real Time Timer Real Time Timer Real Time Timer Real Time Timer
Engine No Yes Yes Yes Yes Yes YesRunning Time
Programmable No No No Yes Yes Yes YesWorking Timer
Event Logs No No No Last 50 events Last 32 events Last 32 events Last 32 eventson device and allevents archived
on PC
J-1939 ECU No No No **only available in **only available in Yes YesCommunication FDJ FLJ
Communication No RS-232 Serial RS-232 Serial RS-232 ModBus RS-232 ModBus RS-232 ModBus RS-232 ModBusStandard Modem RTU, ASCII, ASCII, ASCII,
Standard Modem Standard Modem GSM, SMS Standard ModemEthernet, Internet
Sends SMS to pre-defined GSM numbers for alarms
Controls the generator and monitors status information of the generator by SMS
Remote control via internet, intranet, GSM or dial-up modem
Access to multiple generators by Gen-Agent SCADA software
CanBus J1939 ECU communication
SPN, FMI and OC values reading from engine via J1939
Authorised access, secure communication
Suitable for telecommunication projects
Automatic transfer switching control and engine control
Logs last 32 events & alarm informations
Full metering facility, energy and power measurement
144x204 mm size, Flat type
Automatic Gen-Set Controllerswith Remote Control & Visualisation
3
The status of your generatoris only a text message away :)
Two-way SMS communication(GenSet to mobile)
Options Back
Sender+905305227470
Generator No3:03.07.200816:08:12Level Prealarm
Send commandby SMS
Notification of alarmstatus by SMS
Enquire statusby SMS
Receive feed-backmessage for status
Acknowledgementmessage for
command sent
Options Back
Sender+905305227470
Generator No3:Ok
Enquire for activemeasured values
Enquire forparameter values
by SMS
Feed-back messagefor parametervalues read
Change parametervalues by SMS
Feed-back messagefor active measured
values
Order information
MESSENGER Enhanced automatic Gen Set controller with transfer switching,SMS communication by build-in internal GSM modem and configuration software
#1:read s?
Options Send
Sender+905305227470
Generator No3:AUTO, Engine isnot running, Loadfrom mains
Options Back
#1:read c1
Options Send
#1:read h235
Options Send
Sender+905305227470
Generator No3:1300
Options Back
#1:read w235 1200, p1234
Options Send
#1:read r20
Options Send
Sender+905305227470
Generator No3:380
Options Back
GSMSMS
send/receive
Automatic Gen-Set Controllerswith Remote Control & Visualisation
4
Real-time technology allows for real-time feedback - Know thestatus of your generator instantly! Only a text message away...
sends alarm informations to pre-defined GSM numbers viainternal GSM modem. User may control the device, CLEAR alarms, RESET,change MODE’s, STOP, START, access the PARAMETER’s of device,change the parameters and enquire information about generator’s activestatus by sending and receiving SMS. Accessing and trouble shooting of theGen-Sets outside of residental area & all around the world is possible.
Remote control & visualisationfor multiple Gen-Sets
.PRO enables continuous communication with build in ethernet and dial-up modem facility. Gen-Agent SCADAsoftware offers remote control & visualisation and maintenance management of multiple Gen-Sets from a central computer viainternet by ADSL connected to telephone or local ethernet network. Software also observes for alarms and archieves them.The failures and alarms traced by Gen-Agent SCADA software can be sent to 3 GSM numbers pre-defined in software for yourinformation.
ADSLModem
GSMSMS
Order information
MESSENGER.PRO Enhanced automatic Gen-Set controller with transfer switching,Build-in Ethernet & Dial-up modem communication, multiple Gen-Set visualisation& control by Gen-Agent SCADA software
Gen-Agent SCADA software
Automatic Gen-Set Controllerswith Remote Control & Visualisation
5
3 phase mains and 3 phase generator voltage measurement,3 phase load current and earth current measurement,Contactor open and close relay outputs for mains and generator,Configurable 6 inputs and 4 outputs,3 resistive sender inputs for oil pressure, temperature and level,Speed sensing from alternator voltage or magnetic pickup,Stop or fuel solenoid selection,Programmable weekly working permit calendar,Maintenance warning (working hour or elapsed month),Exercise at programmed time intervals,OFF, Manual, Auto and Test mode,Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,Compatible to Diesel or Gas generators
Automatic Gen-Set Controllers
with Remote Control & Visualisation
Enhanced automaticGen-Set controller with transfer switching
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
4 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputsMESSENGER.PRO
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)C
harg
e G
en.
E.S
top
Generator Mains
Contactoropen / close
8-32Vdc
Supply voltage
Phoneline
Ethernet
Communication
RS-232 ModBus ASCII
5
GSMmodem
MESSENGER
sim cardsocket
XCel
l
6
Can
Bus
J19
39E
CU
com
mun
icat
ion
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
7
EAOM-210.FL
Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3
ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop
Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level
Warning & Electrical tripEarth faultOver currentShort circuit
AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn
Remote control via RS-232 ModBus or dial-up modem,
Authorised access, secure communication,
Automatic transfer switching control and engine control,
Logs last 32 events & alarm informations,
Full metering facility, energy and power measurement,
3 phase mains and 3 phase generator voltage measurement,
3 phase load current and earth current measurement,
Contactor open and close relay outputs for mains and generator,
Configurable 6 inputs and 4 outputs,
Optional configurable 8 inputs and 8 outputs with Expansion I/O Board,
3 resistive sender inputs for oil pressure, temperature and level,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Programmable weekly working permit calendar,
Maintenance warning (working hour or elapsed month),
Exercise at programmed time intervals,
OFF, Manual, Auto and Test mode,
Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,
Compatible to Diesel or Gas generators,
144x204 mm size, Flat type
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
8
EAOM-210.FL
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
4 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactoropen / close
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCII
5
OptionalExpansion I/O Board
Communication
OptionalExpansionI/O Board
EAOM-210.FL.EXR
8 configurabledigital inputs
8 configurablerelay outputs
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Relayoutputs
Analogue inputs
2 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCII
5
OptionalExpansion I/O Board
Communication
OptionalExpansionI/O Board
EAOM-210.FL.EXR
8 configurabledigital inputs
8 configurablerelay outputs
Contactor
2
EAOM-210.FL.S
EAOM-210.FL
Order information
EAOM-210.FL Enhanced automatic Gen-Set controller with transfer switching, LCD display
EAOM-210.FL.S Automatic Gen-Set controller with transfer switching, LCD display
EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable
MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FL) 8-32Vdc supply voltage
ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FL), 1000V galvanic insulation, 8-32Vdc supply voltage
EAOM-210.FL-SOFT PC Communication software for Remote control and Programming
EAOM-210.FL.S-SOFT PC Communication software for Remote control and Programming
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
9
EAOM-210.FLJ
Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3
ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop
Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level
Warning & Electrical tripEarth faultOver currentShort circuit
AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn
CanBus J1939 ECU communication
Remote control via RS-232 ModBus or dial-up modem,
Authorised access, secure communication,
Automatic transfer switching control and engine control,
Logs last 32 events & alarm informations,
Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2
Power factor measurement for 3 phases
SPN, FMI and OC values reading from engine via J1939
3 phase mains and 3 phase generator voltage measurement,
3 phase load current and earth current measurement,
Contactor open and close relay outputs for mains and generator,
Configurable 6 inputs and 4 outputs,
Optional configurable 8 inputs and 8 outputs with Expansion I/O Board,
3 resistive sender inputs for oil pressure, temperature and level,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Programmable weekly working permit calendar,
Maintenance warning (working hour or elapsed month),
Exercise at programmed time intervals,
OFF, Manual, Auto and Test mode,
Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,
Compatible to Diesel or Gas generators,
144x204 mm size, Flat type
CanBus J1939 ECUcommunication
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
10
EAOM-210.FLJ
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
4 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactoropen / close
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCII
5
OptionalExpansion I/O Board
Communication
OptionalExpansionI/O Board
EAOM-210.FL.EXR
8 configurabledigital inputs
8 configurablerelay outputs
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Relayoutputs
Analogue inputs
2 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCII
5
OptionalExpansion I/O Board
Communication
OptionalExpansionI/O Board
EAOM-210.FL.EXR
8 configurabledigital inputs
8 configurablerelay outputs
Contactor
2
EAOM-210.FLJ.S
EAOM-210.FLJ
Can
Bus
J19
39E
CU
com
mun
icat
ion
Can
Bus
J19
39E
CU
com
mun
icat
ion
Order information
EAOM-210.FLJ Enhanced automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm.
EAOM-210.FLJ.S Automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm.
EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable
MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FLJ) 8-32Vdc supply voltage
ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FLJ), 1000V galvanic insulation, 8-32Vdc supply voltage
EAOM-210.FLJ-SOFT PC Communication software for Remote control and Programming
EAOM-210.FLJ.S-SOFT PC Communication software for Remote control and Programming
CanBus J1939 ECUcommunication
Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3
ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop
Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level
Warning & Electrical tripReverse powerEarth faultOver currentShort circuit
AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
11
EAOM-210.FD
Remote control via RS-232 ModBus or dial-up modem,
Authorised access, secure communication,
Automatic transfer switching control and engine control,
Logs last 50 events & alarm informations,
Full metering facility, energy and power measurement,
3 phase mains and 3 phase generator voltage measurement,
3 phase load current and earth current measurement,
Contactor open and close relay outputs for mains and generator,
Configurable 6 inputs and 4 outputs,
3 resistive sender inputs for oil pressure, temperature and level,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Maintenance warning (working hour or elapsed month),
Exercise at programmed time intervals,
OFF, Manual, Auto and Test mode,
Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,
Compatible to Diesel or Gas generators,
144x204 mm size, Flat type
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
12
EAOM-210.FD
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
4 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactoropen / close
8-32VdcSupply voltage
CommunicationRS-232
ModBus RTU
5S
tart
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
2 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCIIor RTU
5
Contactor
2
EAOM-210.FD.S
EAOM-210.FD
Order information
EAOM-210.FD Enhanced automatic Gen-Set controller with transfer switching, LED display
EAOM-210.FD.S Automatic Gen-Set controller with transfer switching, LED display
MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2mRS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage
ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage
EAOM-210.FD-SOFT PC Communication software for Remote control and Programming
EAOM-210.FD.S-SOFT PC Communication software for Remote control and Programming
Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3
ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop
Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level
Warning & Electrical tripReverse powerEarth faultOver currentShort circuit
AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
13
EAOM-210.FDJ
CanBus J1939 ECU communication
Remote control via RS-232 ModBus or dial-up modem,
Authorised access, secure communication,
Automatic transfer switching control and engine control,
Logs last 50 events & alarm informations,
Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2
Power factor measurement for 3 phases
SPN, FMI and OC values reading from engine via J1939
3 phase mains and 3 phase generator voltage measurement,
3 phase load current and earth current measurement,
Contactor open and close relay outputs for mains and generator,
Configurable 6 inputs and 4 outputs,
3 resistive sender inputs for oil pressure, temperature and level,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Maintenance warning (working hour or elapsed month),
Exercise at programmed time intervals,
OFF, Manual, Auto and Test mode,
Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,
Compatible to Diesel or Gas generators,
144x204 mm size, Flat type
CanBus J1939 ECUcommunication
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
14
EAOM-210.FDJ
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
4 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactoropen / close
8-32VdcSupply voltage
CommunicationRS-232
ModBus RTU
5S
tart
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogue inputs
2 configurablerelay outputs
6 configurabledigital inputs
Engine Control
Digital inputs
+Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
ModBus ASCIIor RTU
5
Contactor
2
Can
Bus
J19
39E
CU
com
mun
icat
ion
Can
Bus
J19
39E
CU
com
mun
icat
ion EAOM-210.FDJ.S
EAOM-210.FDJ
Order information
EAOM-210.FDJ Enhanced automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm.
EAOM-210.FDJ.S Automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm.
MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2mRS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage
ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage
EAOM-210.FDJ-SOFT PC Communication software for Remote control and Programming
EAOM-210.FDJ.S-SOFT PC Communication software for Remote control and Programming
CanBus J1939 ECUcommunication
Automatic Gen-Set Controllerswith Transfer Switching
15
EAOM-9F
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorPreheatExternal alarm horn
Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2
Sta
rt
Sol
enoi
d
Mag
netic
Pic
kup
(RP
M)Transistor
outputs
Transistoroutputs
2 configurabledigital inputs
Engine Control
Digital inputs
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
2
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
-Vba
tO
ver c
urre
nt -Vba
tR
emot
e in
hibi
t
Bat
ery
volta
ge
Hor
n O
utpu
t
Con
figur
able
outp
ut
Contactor
Order information
EAOM-9F Automatic Gen-Set controller with transfer switching, LED display
MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-9F) 8-32Vdc supply voltage
EAOM-9F-SOFT PC Communication software for Remote control and Programming
Remote control via RS-232 or standard modem communication,
Automatic transfer switching control and engine control,
3 phase mains and 1 phase generator voltage measurement,
Contactor transistor outputs for mains and generator,
Configurable 2 inputs and 1 output,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Maintenance warning (working hour),
OFF, Manual, Auto and Test mode,
144x204 mm size, Flat type
Order information
EAOM-9 Automatic Gen-Set controller with transfer switching, LED display
EAOM-9-SOFT PC Communication software for Remote control and Programming
Sta
rt
Sol
enoi
d
Mag
netic
Pic
kup
(RP
M)
Relay outputs
Relayoutputs
2 configurabledigital inputs
Engine Control
Digital inputs
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator Mains
Contactor
8-32VdcSupply voltage
CommunicationRS-232
2
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
-Vba
tO
ver c
urre
nt -Vba
tR
emot
e in
hibi
t
Bat
ery
volta
ge
Hor
n O
utpu
t
Con
figur
able
outp
ut
Contactor
Automatic Gen-Set Controllerswith Transfer Switching
16
EAOM-9
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorPreheatExternal alarm horn
Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2
Automatic transfer switching control and engine control,
3 phase mains and 1 phase generator voltage measurement,
Contactor relay outputs for mains and generator,
Configurable 2 inputs and 1 output,
Speed sensing from alternator voltage or magnetic pickup,
Stop or fuel solenoid selection,
Maintenance warning (working hour),
OFF, Manual, Auto and Test mode,
96x96 mm size,
Automatic transfer switching control and engine control,
3 phase mains and 1 phase generator voltage measurement,
Contactor relay outputs for mains and generator,
Configurable 2 inputs and 1 output,
Speed sensing from alternator voltage,
Stop and fuel solenoid selection,
OFF, Manual, Auto and Test mode,
Diesel or Gasoline engine control,
Remote inhibit input,
Adjustable choke time,
Low oil level or pressure input,
Provides charge generator excitation current,
Easy to use and economical,
72x72 mm size,
Automatic Gen-Set Controllerswith Transfer Switching
17
EAOM-19
ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorExternal alarm horn
Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageError indicationProgram parameters
Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2
Order information
EAOM-19 Automatic Gen-Set controller with transfer switching, LED display
Sta
rt
Sol
enoi
d
Relay outputs
Relayoutputs
2 configurabledigital inputs
Engine Control
Digital inputs
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
Generator Mains
Contactor
8-32VdcSupply voltage
2
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
Bat
ery
volta
ge
Con
figur
able
outp
ut
Contactor
Model EAOM-36 EAOM-6 EAOM-7 EAOM-71 EAOM-72F
Dimensions (mm) 72X72 96x96 96x96 96x96 144x204
Display LED LED LED LED LED
Generator No L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NVoltage L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/NMeasurement L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N
Generator No No kVA kVA kVAPowerMeasurement
Load Current No No IL1, IL2, IL3 IL1 IL1, IL2, IL3Measurement
Earth Current No No No No NoMeasurement
Outputs Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn,
Configurable 1 User Configurable 2 User Configurable 2 User Configurable 2 User Configurable 2 User ConfigurableOutputs
Configurable 2 User Configurable 3 User Configurable 3 User Configurable 3 User Configurable 3 User Configurable,Inputs
Outputs Type Relay or Solid State Relay Relay Relay Solid State
Analogue No No No Oil Pressure Oil PressureResistive Fuel Level Fuel LevelSender Inputs Temperature Temperature
Speed Sensing From Alternator From Alternator signal From Alternator signal From Alternator signal From Alternator signalsignal or magnetic pickup or magnetic pickup or magnetic pickup or magnetic pickup
Passwords Operator & Operator & Operator & Operator &Technician Technician Technician Technician Technician
Timer Timer Timer Timer Timer Timer
Engine Running Yes Yes Yes Yes YesTime
Communication RS-232 Serial RS-232 Serial RS-232 Serial RS-232 Serial RS-232 Serial
Auto Start Gen-SetProtection & Controllers
18
Comparison Table
Auto Start Gen-SetProtection & Controllers
19
EAOM-72F
ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn
Monitors3-phase alternator voltage3-phase load currentAlternator frequencyEngine speedGenerator Power (kVA)Oil pressureEngine temperatureFuel levelBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3
Order information
EAOM-72F Auto Start Gen-Set protection and controller, LED display
EAOM-72F-SOFT PC Communication software for Remote control and Programming
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
SolidState
outputs
Analogueinputs
3 configurabledigital inputs
Engine Control
Digital inputs
-Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
Generator
8-32VdcSupply voltage
CommunicationRS-232
3Rem
ote
Sta
rt / S
top
Transistoroutputs
Hor
n O
utpu
t
2 C
onfig
urab
leou
tput
s
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
2
Automatic engine control,
3 phase generator voltage measurement,
3 phase Load current measurement,
Generator power measurement by kVA,
3 Resistive sender inputs for Temperature, Oil Pressure and Level,
Configurable 3 inputs and 2 outputs,
Remote Start/Stop input,
Speed sensing from alternator voltage or magnetic pickup,
Over / Under speed warning and shutdown,
Stop or fuel solenoid selection,
Solenoid output switched negative or positive supply,
Maintenance warning,
144x204 mm size, Flat type
Sta
rt
Sol
enoi
d
Tem
pera
ture
Oil
Pre
ssur
e
Leve
l
Bat
tery
vol
tage
Mag
netic
Pic
kup
(RP
M)
Relayoutputs
Analogueinputs
Engine Control
Generator
8-32VdcSupply voltage
CommunicationRS-232
3 configurabledigital inputsDigital inputs
-Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
3Rem
ote
Sta
rt / S
top
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
Relayoutputs
Hor
n O
utpu
t
2 C
onfig
urab
leou
tput
2
Order information
EAOM-71 Auto Start Gen-Set protection and controller, LED display
EAOM-71-SOFT PC Communication software for Remote control and Programming
Auto Start Gen-SetProtection & Controllers
20
EAOM-71
ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn
Monitors3-phase alternator voltage1-phase load currentAlternator frequencyEngine speedGenerator Power (kVA)Oil pressureEngine temperatureFuel levelBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3
Automatic engine control,
3 phase generator voltage measurement,
1 phase Load current measurement,
Generator power measurement by kVA,
3 Resistive sender inputs for Temperature, Oil Pressure and Level,
Configurable 3 inputs and 2 outputs,
Remote Start/Stop input,
Speed sensing from alternator voltage or magnetic pickup,
Over / Under speed warning and shutdown,
Stop or fuel solenoid selection,
Maintenance warning,
96x96 mm size,
Sta
rt
Sol
enoi
d
Bat
tery
volta
ge
Mag
netic
Pic
kup
(RP
M)Relay
outputsAnalogue
inputs
Engine Control
Generator
8-32VdcSupply voltage
CommunicationRS-232
3 configurabledigital inputsDigital inputs
-Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
3Rem
ote
Sta
rt / S
top
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
Relayoutputs
Hor
n O
utpu
t
2 C
onfig
urab
leou
tput
2
IL1, IL2,IL3
Auto Start Gen-SetProtection & Controllers
21
EAOM-7
ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn
Monitors3-phase alternator voltage3-phase load currentAlternator frequencyGenerator power (kVA)Engine speedBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3
Order information
EAOM-7 Auto Start Gen-Set protection and controller, LED display
EAOM-7-SOFT PC Communication software for Remote control and Programming
Automatic engine control,
3 phase generator voltage measurement,
3 phase Load current measurement,
Generator power measurement by kVA,
Configurable 3 inputs and 2 outputs,
Remote Start/Stop input,
Speed sensing from alternator voltage or magnetic pickup,
Over / Under speed warning and shutdown,
Stop or fuel solenoid selection,
Maintenance warning,
96x96 mm size,
Order information
EAOM-6 Auto Start Gen-Set protection and controller, LED display
EAOM-6-SOFT PC Communication software for Remote control and Programming
Sta
rt
Sol
enoi
d
Bat
tery
volta
ge
Mag
netic
Pic
kup
(RP
M)Relay
outputsAnalogue
inputs
Engine Control
Generator
8-32VdcSupply voltage
CommunicationRS-232
3 configurabledigital inputsDigital inputs
-Vba
t
-Vba
t
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
E.S
top
3Rem
ote
Sta
rt / S
top
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
Relayoutputs
Hor
n O
utpu
t
2 C
onfig
urab
leou
tput
2
Auto Start Gen-SetProtection & Controllers
22
EAOM-6
ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn
Monitors3-phase alternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters
Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureCharging failEmergency stopMaintenance dueSpare-1, 2, 3
Automatic engine control,
3 phase generator voltage measurement,
Configurable 3 inputs and 2 outputs,
Remote Start/Stop input,
Speed sensing from alternator voltage or magnetic pickup,
Over / Under speed warning and shutdown,
Stop or fuel solenoid selection,
Maintenance warning,
96x96 mm size,
Auto Start Gen-SetProtection & Controllers with Key Switch
23
EAOM-36
ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn
MonitorsAlternator frequencyEngine speedEngine running timeError indicationProgram parameters
Fail MonitoringFailed to startLow oil pressureHigh temperatureOver / Under speed failureCharging failSpare-1, 2
Sta
rt
Sol
enoi
d
for EAOM-36.RFRelay outputs
Engine Control
Generator
8-32VdcSupply voltage
2 configurabledigital inputsDigital inputs
-/+V
bat
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
2Rem
ote
Sta
rt / S
top
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
for E
AO
M-3
6.R
F
Con
figur
able
outp
ut
L1,N
relay output
for E
AO
M-3
6.TF
Con
figur
able
outp
ut
solid stateoutput
-Vba
t
Sta
rt
Sol
enoi
d
for EAOM-36.TFSolid state
outputs
FAIL
SA
FE A
pplic
atio
n
Order information
EAOM-36.R Auto Start Gen-Set protection and controller, LED display, with relay outputs
EAOM-36.T Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT)
EAOM-36.RF Auto Start Gen-Set protection and controller, LED display, with relay outputs and fail safe inputs
EAOM-36.TF Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT)and fail safe inputs
Sta
rt
Sol
enoi
d
for EAOM-36.RRelay outputs
Engine Control
Generator
8-32VdcSupply voltage
2 configurabledigital inputsDigital inputs
-/+V
bat
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
2Rem
ote
Sta
rt / S
top
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
for E
AO
M-3
6.R
Con
figur
able
outp
ut
L1,N
relay output
for E
AO
M-3
6.T
Con
figur
able
outp
ut
solid stateoutput
-Vba
t
Sta
rt
Sol
enoi
d
for EAOM-36.TSolid state
outputs
Remote start / stop capability with zero power consumption,
Designed for Generator, Pump and Fire Pump applications,
Automatic engine control,
Automatic shutdown on fault condition
Generator frequency measurement,
Configurable 2 inputs and 1 output,
Remote Start/Stop input,
Speed sensing from alternator voltage,
Over / Under speed warning and shutdown,
Stop or fuel solenoid selection,
72x72 mm size
Sta
rt
Sol
enoi
d
Pre
heat
Engine ControlALT
Alternatorvoltage 8-32Vdc
Supply voltage
Digital inputs
-Vba
t
D+(
W.L
.)
Cha
rge
Gen
.
Aux
iliar
y sh
utdo
wn
-Vba
tLo
w o
il pr
essu
re
-Vba
tH
igh
tem
pera
ture
L1,N
tachometer output(0...1mA)
for ALT and MAGseries
MAGMagneticPickup
-Vba
tA
ux2
inpu
t for
STP
ser
ies
Manual Key Start & Engine Protectionwith Key Switch
24
EAOM-3
ControlsFuel and Stop solenoidStarter motorManual generator start/stopPreheat
MonitorsEngine running timeError indication
Fail MonitoringLow oil pressureHigh temperatureOver speed failureCharging fail
Order informationOverspeed sensing from generator voltage + + + +Overspeed sensing from magnetic pickup + + + +Time meter + + + + + +Stop button + + + + + +Stop/Fuel selection + + + + + +Preheat + + + + + + + + + + + +Aux.In-1 + + + + + + + + + + + +Aux.In-2 + + + + + +
Pro
duct
cod
es
EA
OM
-3
EA
OM
-3-A
LT
EA
OM
-3-M
AG
EA
OM
-3-H
M
EA
OM
-3-H
M-A
LT
EA
OM
-3-H
M-M
AG
EA
OM
-3-S
TP
EA
OM
-3-S
TP-A
LT
EA
OM
-3-S
TP-M
AG
EA
OM
-3-H
M-S
TP
EA
OM
-3-H
M-S
TP-A
LT
EA
OM
-3-H
M-S
TP-M
AG
Automatic shutdown on fault condition,
Alarm and status information,
Auxiliary shutdown input,
Provides charge alternator excitation current,
Over speed protection option with tachometer metering output,
Optional tamper-proof elased time meter,
Optional stop button,
72x72mm size
Automatic Transfer Switch
25
ATS-10
ControlsGenerator remote startLoad transfer to mainsMains and Generator contactor
Monitors3-phase mains voltageAlternator voltageProgram parameters
Order information
ATS-10 Automatic transfer switch, LED display
Digital inputs
Generator Mains
Contactor
8-32VdcSupply voltage
+Vba
tE
ngin
e ru
nnin
g
Rem
ote
Sta
rtou
tput
Contactor
+Vba
tLo
ad G
ener
ator
3 phase Mains voltage measurement,
Single phase Generator voltage measurement,
Optional Load Generator input,
Optional engine running input,
Mains voltage failure detection,
Remote start output,
Emergency backup and Test mode,
Password protection,
72x72 mm size,
Enhanced Automatic Gen-Set Controllerswith Transfer Switching
26
EAOM-210.FL.EXR
Order information
EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable
8 Configurable digital inputs
Selectable input signal hardware type (-Ve or +Ve)
Selectable input signal polarity (Close or Open to activate)
User selectable 21 defined input configurations for each input
8 Configurable relay outputs
Selectable output polarity (NO or NC)
User selectable 93 defined functions for each output
DIN Rail mounting type
Communication to EAOM-210.FL, EAOM-210.FL.S, EAOM-210.FLJ or EAOM-210.FLJ.S by CanBus connection
8-32Vdc supply voltage
Battery Charger
27
GENCHARGER
Order information
GENCHARGER-312E SMPS Battery Charger, 3A Output for 12Vdc battery, 230Vac supply voltage
GENCHARGER-312A SMPS Battery Charger, 3A Output for 12Vdc battery, 115Vac supply voltage
GENCHARGER-512E SMPS Battery Charger, 5A Output for 12Vdc battery, 230Vac supply voltage
GENCHARGER-512A SMPS Battery Charger, 5A Output for 12Vdc battery, 115Vac supply voltage
GENCHARGER-324E SMPS Battery Charger, 3A Output for 24Vdc battery, 230Vac supply voltage
GENCHARGER-324A SMPS Battery Charger, 3A Output for 24Vdc battery, 115Vac supply voltage
GENCHARGER-524E SMPS Battery Charger, 5A Output for 24Vdc battery, 230Vac supply voltage
GENCHARGER-524A SMPS Battery Charger, 5A Output for 24Vdc battery, 115Vac supply voltage
3A or 5A output for 12Vdc and 24Vdc battery
115Vac or 230Vac supply voltage
Short circuit and over current protection
Reverse connection protection
Boost output for quick charging
Durability for voltage fluctuation
Flame resistance plastic box
for long battery life
Company Profile
28
EMKO ELEKTRONIK A.S. has been engaged in the desing, manufacture and
marketing of Measurement and Control Instruments and Temperature Sensors, as
well as in providing the relevant before and after sales technical service since 1986.
Giving the most importance to the customer-oriented approach and to product
functionality and quality, we have carried out the design and manufacture of
programmable multi-function process-control instruments, counters, time-relays,
thermocouples and thermoresistances, control and protection generating system;
gen-set controls, automatic transfer switching, manual-keystarts.
Our product range and service meet the needs of the textile, food, plastic,
glass, automotive, chemicals, iron and steel, cement, machinery production, energy
and other sectors, with regard to the automation and process-control materials and
services that they require. Thanks to the quality policy and procedures issued by
the management of our company, which processes in the TS ISO EN9001 Quality
System Certificate, complete customer satisfaction in the areas of design, production
and service is quaranteed. The design and manufacture of control devices conformed
to the directives covered by the CE brand by performing the
EMI, ESD, EFT, PQF, Surge, LVD, Environmental Conditions tests
on new product designs in the test laboratories on our factory premises.
The following design issues are experimented with in our company:
- Process measurement and control instruments which conform to industrial
standards
- The measurement conversion and control of process parameters in such areas
as temperature, pressure, weight, flow, level, speed, humidity, number,
time, voltage and current etc.
- Temperature sensors , thermocouples and thermores is tances
- Control and protection generating systems; Gen-Set controls, Automatic Transfer
Switchings, Manual-keystarts
Our ‘‘Customer Support Service’’ provides pleasant, cheerful and sincere
approach to ensure that our customers select the most suitable products by providing
satisfactory and correct technical information before the sale and if the orders are
delivered correctly on time by keeping track of orders within the company. Also,
guarantees customer satisfaction at all times, in all places and under all circumstances
by supplying them with speedy and reliable information through our authorized
dealer and service network.
Top Related