FMM-P-S FMM-P-M FluidMonitoring Module

Installation and Maintenance Instructions

English (translation of original instructions)

Documentation no.: 3866049a

(Valid from series no.: 0002S01827N0000401)

Page 2: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Imprint

FMM-P-S / FMM-P-M en(us) Page 2 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Imprint

Publisher and responsible for the content:

HYDAC FILTER SYSTEMS GMBH

Postfach 1251

66273 Sulzbach / Saarland

Germany

Telephone: +49 (0)6897 509 01

Telefax: +49 (0)6897 509 846

E-mail: [email protected]

Homepage: www.hydac.com

Court of Registration: Saarbrücken, HRB 17216

Executive director: Mathias Dieter, Dipl.Kfm. Wolfgang Haering

Documentation Representative

Mr. Günter Harge

c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar

Telephone: ++49 (0)6897 509 1511

Telefax: ++49 (0)6897 509 1394

E-mail: [email protected]

© HYDAC FILTER SYSTEMS GMBH

All rights reserved. No part of this work may be reproduced in any form (print, photocopy or by other means) or processed, duplicated or distributed using electronic systems without the written consent of the publisher. These documents have been created and inspected with the greatest care. However, errors cannot be ruled out completely.

All details are subject to technical modifications. The content of this manual is subject to change without notice.

Page 3: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Documentation Representative

FMM-P-S / FMM-P-M en(us) Page 3 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Content

Imprint............................................................................................................2

Documentation Representative ...................................................................2

Preface...........................................................................................................5

Customer service.........................................................................................6

Modifications to the Product ........................................................................6

Warranty ......................................................................................................6

Using the documentation .............................................................................7

Safety Information and Instructions............................................................8

Hazard symbols...........................................................................................8

Signal words and their meaning in the safety information and instructions ..................................................................................................9

Structure of the safety information and instructions...................................10

Observe regulatory information .................................................................10

Proper/Designated Use .............................................................................11

FMM-P-x-0-CS1xx0................................................................................11

FMM-P-x-1-CS1xx1................................................................................11

Improper Use or Use Deviating from Intended Use ...................................12

Qualifications of personnel / target group ..................................................13

Unpacking the FMM ....................................................................................14

Storing the FMM..........................................................................................14

Decoding the model code label .................................................................15

Checking the scope of delivery .................................................................16

FMM Features..............................................................................................17

Components ..............................................................................................18

FMM-P-S-… ..............................................................................................18

FMM-P-M-…..............................................................................................19

Dimensions..................................................................................................20

FMM-P-S-… ..............................................................................................20

FMM-P-M with AS1000..............................................................................21

FMM-P-M with AS3000..............................................................................22

FMM-P-M with HydacLab ..........................................................................23

Hydraulic diagram.......................................................................................24

Page 4: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Documentation Representative

FMM-P-S / FMM-P-M en(us) Page 4 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM-P-S-… ..............................................................................................24

FMM-P-M-…..............................................................................................24

Installing the FMM.......................................................................................25

Attaching the FMM-P-S .............................................................................26

Attaching the FMM-P-M.............................................................................27

Hydraulic connection of the FMM..............................................................28

Connecting FMM with the hydraulic system ...........................................29

Error messages / Troubleshooting............................................................30

Performing Maintenance ............................................................................31

Changing the Filter Element ......................................................................31

Decommissioning the FMM........................................................................32

Disposing of the FMM.................................................................................32

Contact/Service...........................................................................................33

Ersatzteile / Zubehör...................................................................................34

Spare Parts................................................................................................34

Accessories ...............................................................................................35

Technical data .............................................................................................36

Model Code..................................................................................................37

Index ............................................................................................................38

Page 5: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Documentation Representative

FMM-P-S / FMM-P-M en(us) Page 5 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Preface

For you, as the owner of a product manufactured by us, we have produced this manual, comprising the most important instructions for its operation and maintenance.

It is intended to help you become acquainted with the ins and outs of the product and use it properly.

You should keep it in the vicinity of the product so it is always at your fingertips.

Note that the information on the unit's engineering contained in the documentation was that available at the time of publication.Consequently, there might be deviations in technical details, figures and dimensions.

If you discover errors while reading the documentation or have suggestions or other useful information, please don’t hesitate to contact us:

HYDAC FILTER SYSTEMS GMBHTechnische DokumentationPostfach 12 5166273 Sulzbach / Saar

Germany

We look forward to receiving your input.

“Putting experience into practice”

Page 6: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Documentation Representative

FMM-P-S / FMM-P-M en(us) Page 6 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Customer service If you have any questions, suggestions, or encounter any problems of a technical nature, please don't hesitate to contact us. When contacting us, always include the model/type designation, serial no. and part-no. of the product:

Telefax: ++49 (0) 6897 / 509 - 846

E-mail: [email protected]

Modifications to the Product We would like to point out that changes to the product (e.g. purchasing additional options, etc.) may mean that the information in the operating instructions is no longer applicable or adequate.

After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician.

Please notify us immediately of any modifications made to the product whether by you or a third party.

Warranty For the warranty provided by us, please refer to the General Terms of Sale and Delivery of HYDAC FILTER SYSTEMS GMBH.

You will find this at www.hydac.com -> Legal information.

Page 7: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Documentation Representative

FMM-P-S / FMM-P-M en(us) Page 7 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Using the documentation

Please note that the method described above of locating specific information does not release you from your responsibility for carefully reading the entire manual prior to starting the unit up for the first time and carefully rereading the manual at regular intervals later on.

What do I want to know?

I determine which topic I am looking for.

Where can I find the information I’m looking for?

The documentation has a table of contents at the beginning. There, I select the chapter I'm looking for and the corresponding page number.

The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index number is incremented upward by one number every time the manual is revised or changed.

Chapter description

Page number

Edition date

Document language Documentation no.with index/

file name

Page 8: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 8 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Safety Information and Instructions

The module was built according to the statutory provisions valid at the time of delivery and satisfies current safety requirements.

Any residual hazards are indicated by safety information and instructions and are described in the operating instructions.

Observe all safety and warning instructions attached to the module. They must always be complete and legible.

Do not operate the module unless all the safety devices are present.

Secure the hazardous areas which may arise between the module and other equipment.

Maintain the unit inspection intervals prescribed by law.

Document the results in an inspection certificate and keep it until the next inspection.

Hazard symbols

These symbols are listed for all safety information and instructions in these operating instructions which indicate particular hazards to persons, property or the environment.

Observe these instructions and act with particular caution in such cases.

Pass all safety information and instructions on to other users.

General hazard

Danger due to operating pressure

Risk of burns due to hot surfaces

Page 9: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 9 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Signal words and their meaning in the safety information and instructions

DANGER DANGER indicates a danger with a high risk and which will lead to death or serious injury if not avoided.

WARNING WARNING indicates a danger with a medium risk and which can lead to death or serious injury if not avoided.

CAUTION CAUTION indicates a danger with a low risk and which can lead to minor injury if not avoided.

NOTICE NOTICE indicates a danger which will lead to damage to property if not avoided.

Page 10: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 10 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Structure of the safety information and instructions

All warning instructions in this manual are highlighted with pictograms and signal words. The pictogram and the signal word indicate the severity of the danger.

Warning instructions listed before an activity are laid out as follows:

SIGNAL WORD

Type and source of danger

Consequence of the danger

HAZARD SYMBOL

► Measures to avert danger

Observe regulatory information

Also observe the following regulatory information and guidelines:

Legal and local regulations for accident prevention

Legal and local regulations for environmental protection

Country-specific regulations, organization-specific regulations

Page 11: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 11 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Proper/Designated Use

Use the module only for the application described in the following:

The FluidMonitoring Module FMM is for monitoring solid particle contamination in hydraulic systems.

Proper or designated use of the product extends to the following:

Observing all instructions contained in the instruction manual.

Performing inspection and maintenance work.

Depending on the version (see model code), you may use the FMM only in connection with the following media:

FMM-P-x-0-CS1xx0

NOTICE

Impermissible operating fluid

The FluidMonitoring Module will be destroyed

► The FMM may only be used with mineral oils or mineral oil-based raffinates.

FMM-P-x-1-CS1xx1

NOTICE

Impermissible operating fluid

The FluidMonitoring Module will be destroyed

► The FMM may only be used with HFD-R fluids (phosphate esters, e.g. Skydrol, Fyrquel, HyJet).

Page 12: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 12 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Improper Use or Use Deviating from Intended Use

DANGER

Hazard due to use of the module other than that intended

Bodily injury and damage to property will result when operated improperly.

► Never operate the module in potentially explosive atmospheres.

► The module is only to be used with permissible media.

Any use extending beyond or deviating therefrom shall not be considered intended use. HYDAC Filter Systems GmbH will assume no liability for any damage resulting from such use. The user alone, shall assume any and all associated risk

Improper use may result in hazards and/or will damage the module. Examples of improper use:

Operation in potentially explosive atmospheres.

Operation with a non-approved medium.

Operation under non-approved operational conditions.

Operation when the safety devices are defective.

modifications to the module made by the user or purchaser

Inadequate monitoring of parts that are subject to wear and tear

Improperly performed repair work / maintenance.

Page 13: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Safety Information and Instructions

FMM-P-S / FMM-P-M en(us) Page 13 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Qualifications of personnel / target group

Persons who work on the module must be aware of the associated hazards when using the module.

Operating and specialist personnel must have read and understood the operating instructions, in particular the safety information and instructions, and applicable regulations before beginning work.

The operating instructions and applicable regulations are to kept so they are accessible for operating and specialist personnel.

These operating instructions are intended for:

Operating personnel: such persons have been instructed in module operation and are aware of potential hazards due to improper use.

Specialist personnel: such persons with corresponding specialist training and several years work experience. They are able to assess and perform the work assigned to them, they are also able to recognize potential hazards.

Page 14: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Unpacking the FMM

FMM-P-S / FMM-P-M en(us) Page 14 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Activity Person Knowledge

Transport / storage Auxiliary personnel

Knowledge required

Hydraulic / electrical installation,

first commissioning,

maintenance,

troubleshooting,

repair,

decommissioning,

disassembly

Specialist personnel

Safe handling/use of tools

Fitting and connection of hydraulic lines and pipelines and connections

Fitting and connection of electrical lines, electrical machinery, sockets, etc.

Checking the phase sequence

Product-specific knowledge

Operation

operations control

Specialist personnel

Product-specific knowledge

Knowledge about how to handle operating media.

Knowledge about contamination due to solids and water

Disposal Specialist personnel

Proper and environmentally-friendly disposal of materials and substances

Decontamination of contaminants

Knowledge about reuse

Unpacking the FMM

Before delivery, the FMM is inspected for leaks and proper functioning at the factory, then carefully packed for shipment.

When receiving and unpacking the module, check it for damage in transit. Dispose of the packaging material in an environmentally friendly manner.

Storing the FMM

Store the FMM in a clean, dry place, in the original packing if possible. Do not remove the packing until you are ready to install the unit.

Always store the FMM in a horizontal or vertical position on the block, without its original packaging.

Page 15: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Decoding the model code label

FMM-P-S / FMM-P-M en(us) Page 15 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Drain the FMM completely before putting it into storage. If necessary, rinse the FMM with n-heptane to prevent it from gumming up during storage.

Decoding the model code label

For product identification details of the ConditionSensor see the Model code label. This is located on the back of the unit and contains the exact product description and the serial number.

Row -> Description

Model -> Model code; for details, see page 37

P/N -> Part no.

S/N -> Serial no.

Date -> Year/week of production and hardware index

Min. INLET press.: -> Minimum operating pressure

Max. INLET press.: -> Maximum operating pressure

Page 16: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Checking the scope of delivery

FMM-P-S / FMM-P-M en(us) Page 16 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Checking the scope of delivery

The FluidMonitoring Module FMM comes packed and factory-assembled. Before commissioning the FMM, check the contents of the package to make sure it has not been damaged during transport and that it is complete.

The following items are supplied:

Qty. Description

1 FluidMonitoring Module FMM-P-x

1 FMM-P-x Operating and Maintenance Instructions (this document)

1 CD Operating and Maintenance Instructions CS 1000 (A PC with a PDF display program is required for displaying this.)

1 CD FluMoS light (FluidMonitoring Software)

1 Calibration certificate CS 1000

1 Additional sensor manual (optional)

Page 17: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

FMM Features

FMM-P-S / FMM-P-M en(us) Page 17 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM Features

The FluidMonitoring Module FMM is a sturdy, stationary system for the online measurement of solid particle contamination in hydraulic fluids. The FMM has test connections by which simple integration is possible into existing hydraulic circuits between 5 - 300 bar.

Furthermore, the FluidMonitoring Module FMM-P-M offers the option of recording further parameters such as water saturation, temperature and /or dielectric constant, depending on the configuration.

The advantages of the FMM are:

Cost-effective solution

Early warning in the case of critical machine states

Continuous fluid monitoring

Condition-based maintenance planning

Page 18: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

FMM Features

FMM-P-S / FMM-P-M en(us) Page 18 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Components

The FMM has the following components, depending on the version:

FMM-P-S-…

Item Description

1 FMM-P-S-... connection block

2 Test point 1604 (IN / OUT)

3 Filter element insert

4 ContaminationSensor CS 1000 series

Page 19: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

FMM Features

FMM-P-S / FMM-P-M en(us) Page 19 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM-P-M-…

Item Description

1 FMM-P-M-... connection block

2 Test point 1604 (IN / OUT)

3 Filter element insert

4 ContaminationSensor CS 1000 series

5 AquaSensor AS 1000 series or AquaSensor AS 3000 series or HYDACLab or No additional sensor

Page 20: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Dimensions

FMM-P-S / FMM-P-M en(us) Page 20 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Dimensions

The FMM has the following dimensions, depending on the version and additional sensor:

FMM-P-S-…

Page 21: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Dimensions

FMM-P-S / FMM-P-M en(us) Page 21 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM-P-M with AS1000

Page 22: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Dimensions

FMM-P-S / FMM-P-M en(us) Page 22 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM-P-M with AS3000

Page 23: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Dimensions

FMM-P-S / FMM-P-M en(us) Page 23 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

FMM-P-M with HydacLab

Page 24: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Hydraulic diagram

FMM-P-S / FMM-P-M en(us) Page 24 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Hydraulic diagram

The FMM has the following hydraulic diagram, depending on the version and additional sensor:

FMM-P-S-…

FMM-P-M-…

Page 25: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Installing the FMM

FMM-P-S / FMM-P-M en(us) Page 25 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Installing the FMM

Note that the direction of flow has to be from bottom to top during installation.

When selecting the installation site, check the ambient conditions such as temperature, dust, water, etc. The CS1000 has protection rating IP67 according to DIN 40050 / EN60529 / IEC 529 / VDE 0470.

Attach the FMM at the two mounting holes on the CS 1000 using 2x socket cap screws M8 x 55 mm, or at the 3 holes in the block using 3x socket cap screws M10x50 mm.

Page 26: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Installing the FMM

FMM-P-S / FMM-P-M en(us) Page 26 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Attaching the FMM-P-S

Attach the FMM-P-S... according to the following illustration:

Page 27: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Installing the FMM

FMM-P-S / FMM-P-M en(us) Page 27 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Attaching the FMM-P-M

Attach the FMM-P-M-... according to the following illustration:

Page 28: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Hydraulic connection of the FMM

FMM-P-S / FMM-P-M en(us) Page 28 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Hydraulic connection of the FMM

WARNING

Non-permitted operating pressure

Danger of bodily injury

► Note the maximum operating pressure.

NOTICE

The minimum differential pressure is ≥ 15 bar

If the minimum differential pressure is not given, measuring errors will occur.

► Always observe the minimum differential pressure of ≥ 15 bar

Note that the direction of flow has to be from bottom (IN) to top (OUT) during installation. This prevents measurement errors resulting from trapped air in the system.

The FMM is supplied with two test points (type 1604) on the inlet (IN) and outlet (OUT). Remove the test points to connect via the connector thread G1/4 according to ISO 228.

Page 29: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Hydraulic connection of the FMM

FMM-P-S / FMM-P-M en(us) Page 29 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Test point 1604 Connector thread: G1/4, ISO 228

Ensure the flow rate is controlled by the integrated flow control valve and is regulated to the measurement volume of the CS1000. The flow rate displayed by the CS1000 does not correspond to the total flow through the FMM.

Connecting FMM with the hydraulic system

WARNING

Hydraulic systems are under pressure

Danger of bodily injury

► The hydraulic system must be depressurized before performing any work on the hydraulic system.

Connect the FMM with the hydraulic system as follows:

1. Check the pressure at the measurement point. The pressure must be within the permissible range.

2. Depressurize the system.

3. Connect the return flow line with the outlet port (OUT) of the FMM (connector thread G1/4 ISO 228 or test connection 1604).

Use an internal Ø ≥ 4mm for the return flow line.

4. Now connect the other end of the return-flow line to the system tank, for example.

5. Connect the measurement line to the inlet port (IN) of the FMM. (connector thread G1/4 ISO 228 of test connection 1604)

Use an internal Ø ≤ 4mm for the measurement line to prevent particle deposit.

6. Connect the other end of the measurement line to the measurement point.

7. The hydraulic installation of the FMM is now complete.

Page 30: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Error messages / Troubleshooting

FMM-P-S / FMM-P-M en(us) Page 30 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Error messages / Troubleshooting

The following error message may result when the CS1000 is combined with the FMM connection block.

LED Blink code / Display / Analog output / Switch out

Status To do

Red

19.9 mA / 9.95 V*

open Flow specification not possible

Sensor status is undefined

Check flow

If the oil quality is below the measurement limit (ISO 9/8/7), it may take several measurement cycles until measured values are displayed

Increase inlet pressure or check outlet pressure at measurement point.

The p has to be at least 15 bar -> if OK, change the filter element.

For other error messages, please refer to your CS1000 operating and maintenance instructions.

A PC with an installed PDF display program is required for displaying the CS1000 operation and maintenance instructions on the CD-ROM.

Page 31: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Performing Maintenance

FMM-P-S / FMM-P-M en(us) Page 31 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Performing Maintenance

Replace the filter element at least every six months.

Changing the Filter Element

WARNING

Hydraulic systems are under pressure

Danger of bodily injury

► The hydraulic system must be depressurized before performing any work on the hydraulic system.

Item Description

10 O-ring 10.77x2.62

20 Filter element 25 µm

30 O-ring 20x 2

40 Support ring Ø 20

50 Screw plug

Page 32: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Decommissioning the FMM

FMM-P-S / FMM-P-M en(us) Page 32 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

To change the filter, proceed as follows:

1. Unscrew the screw plug (50) with an Allen wrench (size 10) by turning it counterclockwise, then remove it.

2. Remove the filter element.

3. Remove all old seals and gaskets under the filter element in the block and at the screw plug.

4. Clean the dirt and oil from the screw plug (50) and the element mount bore using a clean absorbent, lint-free cloth.

5. Insert the O-ring (10) into the groove under the filter element in the block designated for that purpose.

6. Put the filter element (20) into the mount bore with the opening facing in the direction of the block. The shape of the bore centers the filter element.

7. Mount the support ring (40) and the O-ring (30) to the screw plug (50). Be sure to use the correct sequence and to mount cleanly and perfectly.

8. Wet the O-ring (30) and the support ring (40) with medium.

9. Turn the screw plug (50) clockwise manually, then tighten it with an Allen wrench (size 10). (Tightening torque: 8 - 10 Nm)

Decommissioning the FMM

To decommission the unit, proceed as follows:

1. Remove the plug from the sensor(s).

2. Depressurize the system.

3. Remove the connected hoses/piping from the FMM.

4. Remove the FMM.

Disposing of the FMM

Dispose of the packaging material in an environmentally friendly manner.

After dismantling the module and separating its various materials, dispose of it in an environmentally friendly manner.

Page 33: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Contact/Service

FMM-P-S / FMM-P-M en(us) Page 33 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Contact/Service

For product information, technical support or if you have comments or suggestions concerning this manual, please contact:

HYDAC FILTER SYSTEMS GMBH

Telephone: ++49 (0) 6897 509 1174

Telefax: ++49 (0) 6897 509 846

E-mail: [email protected]

Regular inspection and maintenance work is indispensable for ensuring trouble-free operation and long service life for your FluidAqua Mobil.

Our HYDAC Servicenter offers you these tasks within agreed-upon time frames and at fixed prices.

HYDAC SERVICE GMBH Friedrichsthaler Straße 15a, Werk 13 66540 Neunkirchen-Heinitz

Germany

Telephone: ++49 (0) 681 509 883

Telefax: ++49 (0) 681 509 324

E-mail: [email protected]

Page 34: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Ersatzteile / Zubehör

FMM-P-S / FMM-P-M en(us) Page 34 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Ersatzteile / Zubehör

Spare Parts

Description Qty Part no.

Manifold block 1 *

Flow control valve 1 3538491

ContaminationSensor CS 1000 series (type depending on the design)

1 *

Fastening screws for the CS 1000 4 *

O-ring (FPM) between CS 1000 and FMM connection block

2 6003048

O-ring (EPDM) between CS 1000 and FMM connection block

2 637473

AquaSensor AS 1000 series 1 *

AquaSensor AS 3000 series 1 *

HYDACLab 1 *

Test point type 1604 (FPM) 2 629477

Test point type 1604 (EPDM) 2 637651

Screw plug for filter element 1 3331617

Filter element replacement kit (FPM), consisting of:

- 2x O-ring, 1x support ring, 1x filter element 1 3348645

Filter element replacement kit (EPDM), consisting of:

- 2x O-ring, 1x support ring, 1x filter element 1 3523517

*) available on request

Page 35: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Ersatzteile / Zubehör

FMM-P-S / FMM-P-M en(us) Page 35 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Accessories

Description Part no.

Socket plug (female), 8-pin, M12x1, with screw clamp 3281243

Socket plug (female) with 2 m line, shielded, 8-pole, M12x1 3281220

Socket plug (female) with 5 m line, shielded, 8-pole, M12x1 3281239

Extension cable 5 m, socket plug (female) 8-pole, M12x1 / socket plug (male) 8-pole, M12x1

3281240

Socket plug (female), 5-pole, M12x1, with screw clamp 6049128

Socket plug (female) with 2 m line, shielded, 5-pole, M12x1

6019455

Socket plug (female) with 5 m line, shielded, 5-pole, M12x1

6019456

Extension cable 5 m, socket plug (female) 5-pole, M12x1 / socket plug (male) 5-pole, M12x1

6040852

For more spare parts and accessories, please refer to the product documentation.

Page 36: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Technical data

FMM-P-S / FMM-P-M en(us) Page 36 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Technical data

Technical Data FMM

Mounting position vertical, with the direction of flow from bottom to top.

Operating pressure 15 … 300 bar / 217 … 4350 psi

Differential pressure ≥ 15 bar

Sealing material FPM / EPDM (According to model code)

Permissible viscosity range 1 … 350 mm²/s

Fluid temperature range 0° … 85° C / 32° … 185° F

Ambient temperature range 0° … 80° C / 32° … 176° F

Storage temperature range -40° … 80° C / -40° … 176° F

Empty weight

FMM-P-S ~ 4.3 kg

FMM-P-M ~ 5.7 kg

For further technical details, please refer to the operating and maintenance manuals of the respective component.

Page 37: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Model Code

FMM-P-S / FMM-P-M en(us) Page 37 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Model Code

FMM - P - M - 0 - CS1220 - A - AS - 0 - 1 - 0 / 000

Product

FMM = FluidMonitoring Module

Hydraulic application

P = Pressure Line (pressure circuit > 15 bar)

Sensor combination

S = CS1000

M = CS1000 + AS1000

L = CS1000 + AS1000 + HydacLab

Seal

0 = FPM

1 = EPDM

ContaminationSensor CS 1000 series

CS1210 = ISO / SAE, without display (FPM)

CS1220 = ISO / SAE, with display (FPM)

CS1310 = ISO / SAE / NAS, without display (FPM)

CS1320 = ISO / SAE / NAS, with display (FPM)

CS1211 = ISO / SAE, without display (EPDM)

CS1221 = ISO / SAE, with display (EPDM)

CS1311 = ISO / SAE / NAS, without display (EPDM)

CS1321 = ISO / SAE / NAS, with display (EPDM)

Analogue interface on the CS 1000

A = 4 … 20 mA

B = 0 … 10 V DC

Additional sensor

z = without sensor

AS = AS1000

AS3 = AS3000

AS31 = AS3100

HL = HydacLab

Z(AS) = prepared for AS1000

Z(HL) = prepared for HydacLab

Hydraulic accumulator

0 = without hydraulic accumulator

Filter

1 = Protective filter, 25 µm

Options

0 = Without

Modification number

000 = Modification number

Page 38: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

Index

FMM-P-S / FMM-P-M en(us) Page 38 / 40

MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17

Index

A Accessories ...................................................... 4, 35 Ambient temperature range.................................. 36 AquaSensor.................................................... 19, 34 Auxiliary personnel ............................................... 14

C Calibration ............................................................ 16 ContaminationSensor ......................... 18, 19, 34, 37 Content ................................................................... 3 Customer service................................................ 3, 6

D Date...................................................................... 15 Description.........................15, 16, 18, 19, 31, 34, 35 Differential pressure ............................................. 36 Dimensions....................................................... 3, 20 Display.................................................................. 30 Disposal................................................................ 14 Documentation Representative .......................... 2, 3

E Empty weight ........................................................ 36 Error ................................................................. 4, 30 Error message.................................................. 4, 30

F Features ........................................................... 3, 17 Filter ....................................4, 12, 18, 19, 31, 34, 37 Filter element...................................... 18, 19, 31, 34 Flow control valve................................................. 34 Fluid temperature range ....................................... 36 FluMoS ................................................................. 16 Fyrquel ................................................................. 11

H Hazard symbol.................................................... 3, 8 HFD ...................................................................... 11 Hydraulic connection ........................................ 4, 28 Hydraulic diagram............................................. 3, 24

I Imprint ................................................................ 2, 3 IN 18, 19, 28, 29 INLET ................................................................... 15 ISO ......................................................28, 29, 30, 37

M Maintenance............................................1, 4, 16, 31 measuring............................................................. 28 Model code........................................................... 15 mounting............................................................... 25 Mounting position ................................................. 36

N NAS...................................................................... 37

O operating ...............6, 7, 8, 11, 13, 14, 15, 28, 30, 36 Operation.........................................................12, 14 OUT.....................................................18, 19, 28, 29

P Proper/Designated Use .................................... 3, 11 Publisher ................................................................ 2

S SAE ...................................................................... 37 select ...................................................................... 7 Sensor .............................................................30, 37 Service ............................................................. 4, 33 Signal word......................................................... 3, 9 signal words ......................................................... 10 Skydrol ................................................................. 11 Specialist personnel ........................................13, 14 Storage temperature range .................................. 36

T Transport .............................................................. 14 Troubleshooting................................................ 4, 30

Page 39: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a
Page 40: FMM-P-S FMM-P-M - HYDAC · Documentation Representative FMM-P-S / FMM-P-M en(us) Page 5 / 40 MoWa FMM-P-x 3866049a en(us) 2013-09-17 2013-09-17 Preface For you, as the owner of a

HYDAC FILTER SYSTEMS GMBH Industriegebiet Postfach 1251 66280 Sulzbach/Saar 66273 Sulzbach/Saar Germany Germany Phone: +49 (0) 6897 509 01 Central Fax: +49 (0) 6897 509 846 (Technical Department) Fax: +49 (0) 6897 509 577 (Sales Department) Internet: www.hydac.com Email: [email protected]