Fi
FITTINGS INDEX
Section F
K-PAK ®
Counter Merchandising System .............2-3
Duraloy® 7 Series
Aluminum or Iron Conduit Bodies.........4-10
Duraloy® 8 Series
Iron Conduit Bodies ...........................11-15
O Series / Duraloy® 5 Series
Aluminum or Malleable Iron Conduit Bodies ..................................16-20
TWO Series
Aluminum Conduit Bodies ..................21-23
MO/MOL/NECLB Series
Aluminum or Iron Mogul Conduit Bodies ......24-27
SLB/SLBM/SOLB/MLB Series
Service Entrance.....................................28
WH Series
Conduit Hubs..........................................29
CL/CLM/TWCL Series
Pulling Elbow, Duct Seal .........................30
FB/STFB Series
Service Entrance.....................................31
F Series
Cast Device Boxes.............................32-39Covers, Accessories ..........................41-43
FSQ/FDQ Series
Custom Drilled & Tapped Device Boxes..40Covers, Accessories ..........................41-43
VJ Series
Outlet Boxes ...........................................44
ENY/EY/EYS/EYD Series
Sealing Fittings ..................................45-47
Sealing Materials ....................................49
ENY40/EYD40 Series
40% Fill Sealing Fittings ..........................48
GEB/GE Series
Aluminum and Iron Outlet Bodies.......50-57
GR Series
Outlet Bodies .....................................58-59
X/XALB Series
Conduit Bodies .......................................60
STANDARD LOCATIONS
HAZARDOUS LOCATIONS
Fii
F
FITTINGS INDEX
Section F
JL/JAL Series
Outlet Bodies ..........................................61
GU/UN Series
Unions ....................................................62
UNF/UNY Series
Expansion Conduit Unions ......................63
PLUG/CUP/AN Series
Threaded Insert Plugs,Rigid Conduit Nipples .............................64
KDB/KB/KSBF Series
Drains and Breathers ..............................65
R/RE/ADUP Series
Reducing Bushings and Adapters...........66
ELBOWS ................................................67
ECF/EKJ Series
Bronze Flexible Couplings ......................68
ECFUF/EKJUF Series
Bronze Flexible Couplings with FemaleSteel Unions.............................................69
EKJ Series
Stainless Steel Flexible Couplings...........70
K Series
Liquidtight Connectors .......................71-73
Z Series
Aluminum Cord Connectors ...............74-76Increased Safety Cord Connectors ....78-80
Z Series
Nylon Cord Connectors...........................77Increased Safety Cord Connectors ....81-82
CTCA Series
Connectors for Tray Cable .....................83
CMCA Series
Metal Clad Cable Connectors .................84
CMCXA Series
Hazardous LocationMetal Clad Cable Connectors .................85
SWZ/LZN Series
Sealing Washers, Locknuts .....................86
ZHLN Series
Increased Safety Locknuts ......................86
PCC/ECC/RACC Series
Conduit Clamps ......................................87
HAZARDOUS LOCATIONS
CONNECTORS - STANDARD / HAZARDOUS LOCATIONS
K-PAK • FITTINGSCOUNTER MERCHANDISING SYSTEM
F2
ApplicationsThe K-PAK® System is designed toenable Killark distributors to featurefast-moving products in counter display areas.
Killark’s best selling standard locationproducts have been repackaged intosmaller shelf packs for effective product family presentation.
The uniformly sized (width and heightare consistent) cartons allow items tobe merchandised on Killark’s K-Pakdisplay unit.
Features/Benefits• Cartons are suitable for counter
merchandising display and/orwarehouse storage.
• Open-top bin box displays prod-ucts for easy customer self-service.
• All cartons are bar coded for easyelectronic identification.
• Conduit bodies are packaged withappropriate covers and gaskets.
K-PAK Carton DimensionsFull depth cartons:
6"W x 81/2"H x 15"D
Half depth cartons:
6"W x 81/2"H x 71/2"D
Display face (width & height) samefor all cartons.
K-PAK Display Dimensions48"W x 54"H x 18"D
Standard Location Fittings for Rigid and IMC
Conduit now available in K-PAK packaging.
See page F3 for ordering information.
K-PAK • FITTINGSCOUNTER MERCHANDISING SYSTEM
F3
F
FEATURES-SPECIFICATIONS
F S / F D B A C K B O X E S / C O V E R S
FS FD Weatherproof Hubs
SLB
O
CATALOG PKGNUMBER DESCRIPTION QTY.
1FA-CP Duplex cover 50
1FT-CP Toggle cover 50
FCLA-CP Duplex cover 25
FDC-1-CP 1/2" FDC box 10
FDC-2-CP 3/4" FDC box 10
FD-1-CP 1/2" FD box 10
FD-2-CP 3/4" FD box 10
FSBC-CP Blank cover 50
FSC-1-CP 1/2" FSC box 15
FSC-2-CP 3/4" FSC box 15
FST-CP Cover 25
FS-1-CP 1/2" FS box 20
FS-2-CP 3/4" FS box 20
O F I T T I N G S
CATALOG PKGNUMBER DESCRIPTION QTY.
OC-1CG 1/2" C w/cover & gasket 40
OC-2CG 3/4" C w/cover & gasket 25
OC-3CG 1" C w/cover & gasket 20
OC-4CG 1-1/4" C w/cover & gasket 8
OC-5CG 1-1/2" C w/cover & gasket 8
OC-6CG 2" C w/cover & gasket 3
OLB-1CG 1/2" LB w/cover & gasket 40
OLB-2CG 3/4" LB w/cover & gasket 25
OLB-3CG 1" LB w/cover & gasket 15
OLB-4CG 1-1/4" LB w/cover & gasket 8
OLB-5CG 1-1/2" LB w/cover & gasket 5
OLB-6CG 2" LB w/cover & gasket 3
OLB-7CG 2-1/2" LB w/cover & gasket 1
OLB-8CG 3" LB w/cover & gasket 1
OLB-9CG 3-1/2" LB w/cover & gasket 1
OLB-0CG 4" LB w/cover & gasket 1
OLL-1CG 1/2" LL w/cover & gasket 40
OLL-2CG 3/4" LL w/cover & gasket 25
OLL-3CG 1" LL w/cover & gasket 15
OLL-4CG 1-1/4" LL w/cover & gasket 8
OLL-5CG 1-1/2" LL w/cover & gasket 8
OLL-6CG 2" LL w/cover & gasket 3
OLR-1CG 1/2" LR w/cover & gasket 40
OLR-2CG 3/4" LR w/cover & gasket 25
OLR-3CG 1" LR w/cover & gasket 15
OLR-4CG 1-1/4" LR w/cover & gasket 8
OLR-5CG 1-1/2" LR w/cover & gasket 8
OLR-6CG 2" LR w/cover & gasket 3
OT-1CG 1/2" T w/cover & gasket 30
OT-2CG 3/4" T w/cover & gasket 25
OT-3CG 1" T w/cover & gasket 15
OT-4CG 1-1/4" T w/cover & gasket 8
OT-5CG 1-1/2" T w/cover & gasket 8
OT-6CG 2" T w/cover & gasket 2
CATALOG PKGNUMBER DESCRIPTION QTY.
SLB-1-CP 1/2" Service entrance LB 50
SLB-2-CP 3/4" Service entrance LB 25
SLB-3-CP 1" Service entrance LB 25
S L B F I T T I N G S
CATALOG PKGNUMBER DESCRIPTION QTY.
WH-1 1/2" Condui t hub 25
WH-2 3/4" Condui t hub 25
WH-3 1" Condui t hub 25
W H W E AT H E R P R O O F H U B S
CATALOG PKGNUMBER DESCRIPTION QTY.
TWOC-1C 1/2" C w/cover & gasket 40
TWOC-2C 3/4" C w/cover & gasket 25
TWOC-3C 1" C w/cover & gasket 20
TWOLB-1C 1/2" LB w/cover & gasket 40
TWOLB-2C 3/4" LB w/cover & gasket 25
TWOLB-3C 1" LB w/cover & gasket 15
TWOLRL-1C 1/2" LR w/cover & gasket 40
TWOLRL-2C 3/4" LR w/cover & gasket 25
TWOLRL-3C 1" LR w/cover & gasket 15
TWOT-1C 1/2" T w/cover & gasket 30
TWOT-2C 3/4" T w/cover & gasket 25
TWOT-3C 1" T w/cover & gasket 15
T W F I T T I N G S
DURALOY® 7 SERIES • FITTINGSALUMINUM OR IRON CONDUIT BODIES
F4
FEATURES-SPECIFICATIONS
Applications
To provide access to conductors for
pulling, splicing, and maintenance.
Threaded for rigid conduit and IMC.
Features
•Intermateability UL Listed and CSA
Certified interchangeability with
competitive products
• Enhanced sealing capabilities
neoprene sealing gaskets provide a
NEMA 3 Seal
• High-quality sealing hardware 316
stainless steel cover screws and
washers with neoprene gaskets
• Suitable for wet locations
when used with gaskets
• Innovative spring clip design for
installation ease and repeat usage
• Smooth integral wire bushings
protects cable from damage when
wires are pulled through opening
• For use with threaded rigid conduit
steel or aluminum
• Ten standard hub configurations
• Flat-back design for greater wiring
capacity and mounting stability
LR Type
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
LR Type
Material/Finish
Aluminum
• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically applied
powder coating
Dimensions
LR17
LR27
LR37
LR47
LR57
LR67
LR77
LR87
LR97
LR107
LR17SA
LR27SA
LR37SA
LR47SA
LR57SA
LR67SA
LR77SA
LR87SA
LR97SA
LR107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-11/16"(119)
5-3/8"(137)
6-5/16"(160)
6-13/16"(173)
7-1/4"(184)
8-1/4"(210)
10-15/16"(278)
10-15/16"(278)
13"(330)
13"(330)
1-7/16"(37)
1-11/16"(43)
1-7/8"(48)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
2-5/16"(59)
2-5/8"(67)
3-1/16"(78)
3-1/2"(89)
3-11/16"(94)
4-1/4"(108)
6-3/16"(157)
6-3/16"(157)
7-1/4"(184)
7-1/4"(184)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
4-3/4"(121)
4-3/4"(121)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
10-1/4"(260)
10-1/4"(260)
4-1/16"(103)
4-5/8"(117)
5-3/8"(137)
5-3/4"(146)
6-1/16"(154)
6-3/4"(171)
8-3/4" (222)
8-3/4" (222)
10-5/16"(262)
10-5/16"(262)
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
2-5/8"(67)
2-5/8"(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L R T Y P E C O N D U I T B O D Y *
A B C D E F G
Duraloy Iron
• Class 30 gray iron alloy
• Superior corrosion protection
tri-coat finish of electrozinc,
chromate sealant and electrostati-
cally applied powder coating.
* For conduit body packaged with cover and gasket, add CG to the catalog number.
F
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
DURALOY® 7 SERIES • FITTINGSALUMINUM OR IRON CONDUIT BODIES
F5
FEATURES-SPECIFICATIONS
L Type T Type
T Type
L Type
Dimensions
T17
T27
T37
T47
T57
T67
T77
T87
T97
T107
T17SA
T27SA
T37SA
T47SA
T57SA
T67SA
T77SA
T87SA
T97SA
T107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-11/16"(000)
6-5/16"(000)
7-5/8"(194)
8"(203)
8-7/16"(214)
9-7/16"(240)
12-3/4"(324)
12-3/4"(324)
14-7/8"(378)
14-7/8"(378)
1-13/16"(46)
2-1/16"(52)
2-1/4"(57)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
2-1/2"(64)
2-3/4"(67)
3-1/4"(83)
3-1/2"(89)
3-11/16"(94)
4-1/4"(108)
6-3/16"(157)
6-3/16"(157)
7-1/4"(184)
7-1/4"(184)
—
—
—
—
—
—
—
—
—
—
6.2
9.5
11.5
20.0
27.0
50.0
134.0
134.0
238.0
238.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
T T Y P E C O N D U I T B O D Y *
A B C D E F G
L17
L27
L37
L47
L57
L67
L77
L87
L17SA
L27SA
L37SA
L47SA
L57SA
L67SA
L77SA
L87SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4-11/16"(119)
5-3/8"(137)
6-5/16"(160)
6-13/16"(173)
7-1/4"(184)
8-1/4"(210)
10-15/16"(278)
10-15/16"(278)
1-7/16"(37)
1-11/16"(43)
1-7/8"(48)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
2-5/16"(59)
2-5/8"(67)
3-1/16"(78)
3-1/2"(89)
3-11/16"(94)
4-1/4"(108)
6-3/16"(157)
6-3/16"(157)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
4-3/4"(121)
4-3/4"(121)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
10-1/4"(260)
10-1/4"(260)
4-1/16"(103)
4-5/8"(117)
5-3/8"(137)
5-3/4"(146)
6-1/16"(154)
6-3/4"(171)
8-3/4" (222)
8-3/4" (222)
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
2-5/8"(67)
2-5/8"(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L T Y P E C O N D U I T B O D Y *
A B C D E F GSee page F4 for Standard Materials & Finish
1
1L type is double faced and may be used as LL or LR. Has 2 openings, one ofwhich is furnished with a blank sheet cover.
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 7 SERIES • FITTINGSALUMINUM OR IRON CONDUIT BODIES
F6
FEATURES-SPECIFICATIONS
E Type
TA Type
TA Type
TB Type
TB Type
E17
E27
E37
E17SA
E27SA
E37SA
1/2"
3/4"
1"
4-11/16"(119)
5-3/8"(137)
6-5/16"(160)
1-7/16"(37)
1-11/16"(43)
1-7/8"(48)
1-1/2"(38)
1-3/4"(67)
1-15/16"(49)
1"(25)
1-1/8"(29)
1-3/8"(35)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
4.0
7.0
11.0
HUBSIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONS VOLUMECU. IN.
E T Y P E C O N D U I T B O D Y *
A B C D E F G
TA17
TA27
TA37
TA47
TA57
TA67
TA17SA
TA27SA
TA37SA
TA47SA
TA57SA
TA67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"(144)
6-5/16"(160)
7-5/8"(194)
8"(203)
8-7/16"(214)
9-7/16"(240)
2-5/8"(67)
2-7/8"(73)
3-3/8"(86)
3-1/2"(89)
3-3/4"(95)
4-5/16"(110)
2-1/2"(64)
2-3/4"(67)
3-1/4"(000)
3-1/2"(89)
3-11/16"(94)
4-1/4"(108)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(000)
1-1/4"(32)
1-1/2"(38)
6 .2
9.5
15.5
20.0
27.0
50.0
HUB SIZE
CATALOG NUMBER DIMENSIONS VOLUMECU. IN.
TA T Y P E C O N D U I T B O D Y *
A B C D E F G
TB17
TB27
TB37
TB47
TB57
TB67
TB17SA
TB27SA
TB37SA
TB47SA
TB57SA
TB67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"(144)
6-5/16"(160)
7-5/8"(194)
8"(203)
8-7/16"(214)
9-7/16"(240)
2-5/8"(67)
2-7/8"(73)
3-3/8"(86)
3-1/2"(89)
3-3/4"(95)
4-5/16"(110)
1-11/16"(43)
1-7/8"(67)
3-3/8"(86)
3-1/2"(89)
3-3/4"(95)
4-5/16"(110)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
6 .2
9.5
15.5
20.0
27.0
50.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
T B T Y P E C O N D U I T B O D Y *
A B C D E F G
See page F4 for Standard Materials & Finish
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
E Type
Dimensions
KILLARKALUM.
DURALOYIRON
* For conduit body packaged with cover and gasket, add CG to the catalog number.
X Type
C Type
Dimensions
DURALOY® 7 SERIES • FITTINGSALUMINUM OR IRON CONDUIT BODIES
F7
FEATURES-SPECIFICATIONS
X Type C Type
X17
X27
X37
X47
X57
X67
X17SA
X27SA
X37SA
X47SA
X57SA
X67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"(144)
6-5/16"(160)
7-5/8"(194)
8"(203)
8-7/16"(214)
9-7/16"(240)
1-3/8"(35)
2-1/16"(52)
2-1/4"(57)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
3-3/8"(86)
3-9/16"(67)
4-3/8"(111)
4-11/16"(000)
4-7/8"(124)
5-7/16"(138)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
6 .2
9.5
15.5
20.0
27.0
50.0
HUBSIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
X T Y P E C O N D U I T B O D Y *
A B C D E F G
C17
C27
C37
C47
C57
C67
C77
C87
C97
C107
C17SA
C27SA
C37SA
C47SA
C57SA
C67SA
C77SA
C87SA
C97SA
C107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-1/2"(140)
6-3/16"(157)
7-7/16"(189)
8"(203)
8-7/16"(214)
9-7/16"(240)
12-3/4"(324)
12-3/4"(324)
14-7/8"(378)
14-7/8"(378)
1-7/16"(37)
1-11/16"(43)
1-7/8"(48)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
1-1/2"(38)
1-3/4"(67)
1-15/16"(49)
2-5/16"(59)
2-1/2"(64)
3-1/16"(78)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
4-3/4"(121)
4-3/4"(121)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
10-1/4"(260)
10-1/4"(260)
—
—
—
—
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
2-5/8"(67)
2-5/8"(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
C T Y P E C O N D U I T B O D Y *
A B C D E F G
See page F4 for Standard Materials & Finish
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
F
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 7 SERIES • FITTINGSALUMINUM OR IRON CONDUIT BODIES
F8
FEATURES-SPECIFICATIONS
LB Type
LB17
LB27
LB37
LB47
LB57
LB67
LB77
LB87
LB97
LB107
LB17SA
LB27SA
LB37SA
LB47SA
LB57SA
LB67SA
LB77SA
LB87SA
LB97SA
LB107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-11/16"(119)
5-3/8"(137)
6-5/16"(160)
6-13/16"(173)
7-1/4"(184)
8-1/4"(210)
10-15/16"(278)
10-15/16"(278)
13"(330)
13"(330)
2-1/4"(57)
2-1/2"(64)
3"(76)
3-1/2"(89)
3-3/4"(95)
4-5/16"(109)
6-3/16"(157)
6-3/16"(157)
7-1/4"(184)
7-1/4"(184)
1-1/2"(38)
1-3/4"(67)
1-15/16"(49)
2-5/16"(59)
2-1/2"(64)
3-1/16"(78)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
4-3/4"(121)
4-3/4"(121)
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
10-1/4"(260)
10-1/4"(260)
4-1/16"(103)
4-5/8"(117)
5-3/8"(137)
5-3/4"(146)
6-1/16"(154)
6-3/4"(171)
8-3/4" (222)
8-3/4" (222)
10-5/16"(262)
10-5/16"(262)
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
2-5/8"(67)
2-5/8"(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUBSIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L B T Y P E C O N D U I T B O D Y *
A B C D E F G
LL17
LL27
LL37
LL47
LL57
LL67
LL77
LL87
LL97
LL107
LL17SA
LL27SA
LL37SA
LL47SA
LL57SA
LL67SA
LL77SA
LL87SA
LL97SA
LL107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1-7/16"(37)
1-11/16"(43)
1-7/8"(48)
2-5/16"(59)
2-9/16"(65)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-3/8"(137)
5-3/8"(137)
2-5/16"(59)
2-5/8"(67)
3-1/16"(78)
3-1/2"(89)
3-11/16"(94)
4-1/4"(108)
6-3/16"(157)
6-3/16"(157)
7-1/4"(184)
7-1/4"(184)
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L L T Y P E C O N D U I T B O D Y *
A B C D E F G
Dimensions
LL Type
LL Type
LB Type
See page F4 for Standard Materials & Finish
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
3-3/16"(81)
3-13/16"(97)
4-1/2"(114)
5"(127)
5-7/16"(138)
6-3/8"(162)
8-3/8"(213)
8-3/8"(213)
10-1/4"(260)
10-1/4"(260)
4-1/16"(103)
4-5/8"(117)
5-3/8"(137)
5-3/4"(146)
6-1/16"(154)
6-3/4"(171)
8-3/4" (222)
8-3/4" (222)
10-5/16"(262)
10-5/16"(262)
5/8"(16)
3/4"(19)
7/8"(22)
1-1/8"(29)
1-1/4"(32)
1-1/2"(38)
2-1/8"(54)
2-1/8"(54)
2-5/8"(67)
2-5/8"(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
1"(25)
1-1/8"(29)
1-3/8"(35)
1-13/16"(46)
2-1/16"(52)
2-5/8"(67)
3-7/8"(98)
3-7/8"(98)
4-3/4"(121)
4-3/4"(121)
4-11/16"(119)
5-3/8"(137)
6-5/16"(160)
6-13/16"(173)
7-1/4"(184)
8-1/4"(210)
10-15/16"(278)
10-15/16"(278)
13"(330)
13"(330)
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 7 SERIES • FITTINGSALUMINUM AND STEEL COVERS AND GASKETS
F9
FEATURES-SPECIFICATIONS
FStamped Material/FinishAluminum
• 316 Stainless steel screws
• Natural finish
Galvanized Steel
• 316 Stainless steel screws
• Natural finish
S TA M P E D A L U M I N U M A N D S TA M P E D S T E E L C O V E R S
170
270
370
470
570
670
870
870
970
970
170SA
270SA
370SA
470SA
570SA
670SA
870SA
870SA
970SA
970SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (32)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
9/16" (14)
9/16" (14)
9/16" (14)
9/16" (14)
LENGTH WIDTH HEIGHT
Cast Material/FinishCopper-free Aluminum (less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Duraloy Class 30 Gray Iron Alloy
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
• 316 Stainless steel screws
Stamped Covers Cast Covers
HUB SIZESTAMPEDSTEEL
KILLARKALUMINUM
CATALOG NUMBER DIMENSIONS
C A S T A L U M I N U M A N D C A S T I R O N C O V E R S
170C
270C
370C
470C
570C
670C
870C
870C
970C
970C
170CSA
270CSA
370CSA
470CSA
570CSA
670CSA
870CSA
870CSA
970CSA
970CSA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (32)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
LENGTH WIDTH HEIGHTHUB SIZEKILLARK
ALUMINUM
CATALOG NUMBER DIMENSIONS
Dimensions
Stamped Covers
DURALOYIRON
Cast Covers
DURALOY® 7 SERIES • FITTINGSGASKETS
F10
FEATURES-SPECIFICATIONS
GASK571
GASK572
GASK573
GASK574
GASK575
GASK576
GASK578
GASK578
GASK579
GASK579
Material• Open cell neoprene
Cover Gaskets
C O V E R G A S K E T S ( O P E N C E L L N E O P R E N E )
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (38)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
LENGTH WIDTH HEIGHTHUB SIZECATALOG NUMBER
DIMENSIONS
Dimensions
DURALOY® 8 SERIES • FITTINGSIRON CONDUIT BODIES
F11
FEATURES-SPECIFICATIONS
F
C Type
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
C T Y P E C O N D U I T B O D Y *
ApplicationsTo provide access to conductorsfor pulling, splicing, and mainte-nance. Threaded for rigid conduitand IMC.
Features• Completely interchangeable with
competative bodies, gaskets,and covers
• Flat back design provides greatercubic capacity for easier wirepulling and more room for splicing
• Raintight when used with gasketedcovers
• Stainless steel screws onstamped and cast covers
• Smooth integral wire bushings
Material/FinishDuraloy Class 30 Gray Iron Alloy
• Tri-coat finish of electrozinc, chromate sealant, and electrosta-tically applied powder coating.
C Type
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.A B C D E F G
C18
C28
C38
C448
C58
C68
C78
C88
5-5/16"(135)
6-9/16"(167)
7-9/16"(192)
8-7/16"(214)
10-3/8"(264)
12-3/8"(314)
15-5/8"(397)
15-5/8"(397)
1-15/32"(37)
1-11/16"(43)
1-31/32"(50)
2-3/8"(60)
2-25/32"(71)
3-9/16"(90)
4-7/16"(113)
4-13/16"(122)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-5/32"(55)
2-25/32"(71)
3-27/32"(98)
5"(127)
5"(127)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
4-1/4"(108)
4-1/4"(108)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-15/16"(151)
6-1/2"(165)
8-5/8"(219)
10-7/8"(276)
10-7/8"(276)
—
—
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(28)
1-3/8"(35)
1-7/8"(48)
2-1/2"(64)
2-1/2"(64)
5 .0
8.0
12.25
23.25
42.50
105.00
200.00
217.00
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
Dimensions
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 8 SERIES • FITTINGSIRON CONDUIT BODIES
F12
FEATURES-SPECIFICATIONS
LB Type LL Type
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
L B T Y P E C O N D U I T B O D Y *
L L T Y P E C O N D U I T B O D Y *
LB Type
LL Type
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.A B C D E F G
5-3/32"(129)
5-3/4"(146)
6-5/8"(168)
7-1/2"(191)
9-1/8"(232)
11-1/8"(283)
13-15/16"(354)
13-15/16"(354)
16-7/8"(429)
16-7/8"(429)
2-9/32"(58)
2-1/2"(64)
2-29/32"(74)
3-5/16"(84)
4-1/32"(102)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
7-9/16"(192)
7-13/16"(198)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-5/32"(55)
4-25/32"(121)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
7-9/16"(192)
7-13/16"(198)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
4-1/4"(108)
4-1/4"(108)
5-7/16"(138)
5-7/16"(138)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-15/16"(151)
6-1/2"(165)
8-5/8"(219)
10-7/8"(276)
10-7/8"(276)
13-7/8"(352)
13-7/8"(352)
4-3/8"(111)
4-29/32"(125)
5-23/32"(145)
6-13/32"(163)
7-3/4"(197)
9-3/16"(233)
11-7/16"(291)
11-7/16"(291)
13-3/4"(349)
13-3/4"(349)
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(28)
1-3/8"(35)
1-7/8"(48)
2-1/2"(64)
2-1/2"(64)
3-1/8"(79)
3-1/8"(79)
5 .0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
380.0
400.0
LB18
LB28
LB38
LB448
LB58
LB68
LB78
LB888
LB98
LB108
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
DIMENSIONS
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.A B C D E F G
5-3/32"(129)
5-3/4"(146)
6-5/8"(168)
7-1/2"(191)
9-1/8"(232)
11-1/8"(283)
13-15/16"(354)
13-15/16"(354)
2-9/32"(56)
2-1/2"(64)
2-29/32"(74)
3-5/16"(84)
4-1/32"(102)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-5/32"(55)
4-25/32"(121)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
4-1/4"(108)
4-1/4"(108)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-15/16"(151)
6-1/2"(165)
8-5/8"(219)
10-7/8"(276)
10-7/8"(276)
4-3/8"(111)
4-29/32"(125)
5-23/32"(145)
6-13/32"(163)
7-3/4"(197)
9-3/16"(233)
11-7/16"(291)
11-7/16"(291)
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(28)
1-3/8"(35)
1-7/8"(48)
2-1/2"(64)
2-1/2"(64)
5 .0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
LL18
LL28
LL38
LL448
LL58
LL68
LL78
LL888
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
See page F11 for Standard Materials & Finish
Dimensions
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 8 SERIES • FITTINGSIRON CONDUIT BODIES
F13
FEATURES-SPECIFICATIONS
F
LR Type T Type
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
See page F11 for Standard Materials & Finish
Dimensions
L R T Y P E C O N D U I T B O D Y *
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.A B C D E F G
5-3/32"(129)
5-3/4"(146)
6-5/8"(168)
7-1/2"(191)
9-1/8"(232)
11-1/8"(283)
13-15/16"(354)
13-15/16"(354)
1-15/16"(49)
1-11/16"(43)
1-31/32"(50)
2-3/8"(60)
2-25/32"(71)
3-9/16"(90)
4-7/16"(113)
4-13/16"(122)
2-9/32"(58)
2-1/2"(64)
2-29/32"(74)
3-5/16"(84)
4-1/32"(102)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
1"(52)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
4-1/4"(108)
4-1/4"(108)
3-9/32"(83)
3-15/16"(84)
4-17/32"(115)
5-15/16"(151)
6-1/2"(165)
8-5/8"(219)
10-7/8"(276)
10-7/8"(276)
4-3/8"(111)
4-29/32"(125)
5-23/32"(145)
6-13/32"(163)
7-3/4"(199)
9-3/16"(233)
11-7/16"(291)
11-7/16"(291)
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(28)
1-3/8"(35)
1-7/8"(48)
2-1/2"(64)
2-1/2"(64)
5 .0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
LR18
LR28
LR38
LR448
LR58
LR68
LR78
LR888
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
T T Y P E C O N D U I T B O D Y *
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.A B C D E F G
5-15/16"(151)
6-9/16"(167)
7-9/16"(192)
8-7/16"(214)
10-3/8"(264)
12-3/8"(314)
15-5/8"(397)
15-5/8"(397)
1-25/32"(45)
2"(51)
2-9/32"(58)
2-5/8"(67)
2-25/32"(71)
3-9/16"(90)
4-7/16"(113)
4-13/16"(122)
2-5/16"(59)
2-1/2"(64)
2-25/32"(71)
3-1/8"(79)
4-1/32"(102)
5-1/8"(130)
6-11/16"(170)
6-11/16"(170)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
4-1/4"(108)
4-1/4"(108)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-5/16"(135)
6-1/2"(165)
8-5/8"(219)
10-11/16"(271)
10-11/16"(271)
—
—
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(28)
1-3/8"(35)
1-7/8"(48)
2-1/2"(64)
2-1/2"(64)
6 .0
10.0
15.0
25.0
44.0
105.0
200.0
217.0
T18
T28
T38
T448
T58
T68
T78
T88
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
LR Type
T Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 8 SERIES • FITTINGSIRON CONDUIT BODIES
F14
FEATURES-SPECIFICATIONS
TB Type X Type
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
TB Type
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.
T B T Y P E C O N D U I T B O D Y *
A B C D E F G5-15/16"(151)
6-9/16"(167)
7-9/16"(192)
8-7/16"(214)
10-3/8"(264)
12-3/8"(314)
2-15/16"(75)
2-1/2"(64)
2-25/32"(71)
3-1/8"(79)
4-1/32"(102)
5-1/8"(130)
1-15/16"(49)
1-21/32"(42)
1-27/32"(47)
2-3/16"(55)
2-25/32"(71)
3-7/8"(98)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-5/16"(135)
6-1/2"(165)
8-5/8"(219)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(26)
1-3/8"(35)
1-7/8"(48)
6 .0
10.0
15.0
25.0
44.0
105.0
TB18
TB28
TB38
TB448
TB58
TB68
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
DIMENSIONS
See page F11 for Standard Materials & Finish
Dimensions
HUB SIZE
CATALOG NUMBER
VOLUMECU. IN.
X T Y P E C O N D U I T B O D Y *
A B C D E F G5-15/16"(151)
6-9/16"(167)
7-9/16"(192)
8-7/16"(214)
10-3/8"(264)
12-3/8"(314)
1-25/32"(45)
2"(51)
2-9/32"(58)
2-5/8"(67)
2-25/32"(71)
3-9/16"(90)
3-1/8"(79)
3-15/16"(100)
3-23/32"(94)
4-1/16"(103)
5-9/32"(134)
6-3/8"(162)
1"(25)
1-3/16"(30)
1-3/8"(35)
1-3/4"(44)
2-3/32"(53)
3"(76)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
5-5/16"(135)
6-1/2"(165)
8-5/8"(219)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
1-3/32"(26)
1-3/8"(35)
1-7/8"(48)
6 .0
10.0
15.0
25.0
44.0
105.0
X18
X28
X38
X448
X58
X68
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
DIMENSIONS
X Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY® 8 SERIES • FITTINGSIRON COVERS AND GASKETS
F15
FEATURES-SPECIFICATIONS
F
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
See page F11 for Standard Materials & Finish
OVERALL DIMENSIONS
C A S T I R O N C O V E R S
180F
280F
380F
480F
580F
680F
880F
880F
980F
980F
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
HEIGHTCATALOG NUMBER
HUB SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
OVERALL DIMENSIONS
S TA M P E D S T E E L C O V E R S
180S
280S
380S
480S
580S
680S
880S
880S
980S
980S
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
9/16"(14)
9/16"(14)
9/16"(14)
9/16"(14)
HEIGHTCATALOG NUMBER
HUB SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
OVERALL DIMENSIONS
C O V E R G A S K E T S
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
HEIGHTCATALOG NUMBER
HUB SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
GASK851N
GASK852N
GASK853N
GASK854N
GASK805N
GASK806N
GASK808N
GASK808N
GASK809N
GASK809N
Cover Gaskets (Neoprene)
Stamped Steel CoversCast Covers
Cast Material/FinishDuraloy Class 30 Gray Iron Alloy
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
• 300 Series stainless steel screws
Galvanized Steel
• Natural finish
• 300 Series stainless steel screws
Material/Finish• Neoprene. Compression molded.
O SERIES / DURALOY ® 5 SERIES • FITTINGSALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F16
FEATURES-SPECIFICATIONS
E TypeC Type
ApplicationsTo provide access to conductors forpulling, splicing, and maintenance.Threaded for rigid conduit and IMC.
Features• Tapered threaded hubs (NPT)
• Raintight when used with gasketedcovers
• Malleable iron suitable for use in concrete
• Interchangeable with competitive products
• Stainless steel screws on stampedand cast covers
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Duraloy Malleable Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating.
C Type
Dimensions
E Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/8"(137)
6-1/8"(156)
7-1/8"(181)
9-1/8"(232)
9-1/4"(235)
11-7/8"(302)
15-1/8"(384)
15-1/8"(384)
18-3/8"(467)
18-3/8"(467)
1-3/8"(35)
1-5/8"(41)
2"(51)
2-5/8"(67)
2-3/4"(70)
3-1/2"(89)
4"(102)
4-3/4"(121)
5-1/2"(140)
5-5/8"(143)
1-3/8"(35)
1-5/8"(67)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-11/16"(94)
3-11/16"(94)
4-7/8"(124)
4-7/8"(124)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
10-5/8"(270)
10-5/8"(270)
13-1/8"(333)
13-1/8"(333)
—
—
—
—
—
—
—
—
—
—
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
1-13/16"(54)
2-3/16"(54)
2-1/2"(67)
2-3/4"(67)
4.0
7.0
12.0
32.0
36.0
70.0
153.0
181.0
290.0
320.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
C T Y P E C O N D U I T B O D Y *
A B C D E F G
OC-1M
OC-2M
OC-3M
OC-4M
OC-5M
OC-6M
OC-7M
OC-8M
OC-9M
OC-0M
OC-1
OC-2
OC-3
OC-4
OC-5
OC-6
OC-7
OC-8
OC-9
OC-0
OE-1M
OE-2M
OE-3M
OE-1
OE-2
OE-3
1/2"
3/4"
1"
4-5/8"(117)
5-3/8"(41)
6-1/4"(159)
1-3/8"(35)
1-5/8"(137)
2"(51)
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
1"(25)
1-7/32"(29)
1-15/32"(35)
3-9/32"(83)
3-15/16"(100)
4-17/32"(115)
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
4.0
7.0
12.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
E T Y P E C O N D U I T B O D Y *
A B C D E F G
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY ® 5 SERIES • FITTINGSALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F17
FEATURES-SPECIFICATIONS
F
Dimensions
LB Type
LB Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-17/32"(115)
5-3/4"(146)
6-5/8"(168)
7-1/2"(191)
9-1/8"(232)
10"(254)
13-15/16"(354)
13-15/16"(354)
16-7/8"(429)
16-7/8"(429)
2-9/32"(83)
2-1/2"(64)
2-29/32"(74)
3-3/16"(81)
4"(102)
4-13/16"(122)
6-1/8"(156)
6-1/2"(165)
7-9/16"(192)
7-13/16"(198)
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-11/16"(94)
3-11/16"(94)
4-7/8"(124)
4-7/8"(124)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
10-5/8"(270)
10-5/8"(270)
13-1/8"(333)
13-1/8"(333)
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
2-1/2"(64)
2-3/16"(54)
2-1/2"(67)
2-3/4"(70)
4.0
7.0
12.0
128.8
36.0
70.0
142.0
173.0
292.0
324.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L B T Y P E C O N D U I T B O D Y *
A B C D E F G
OLB-1M
OLB-2M
OLB-3M
OLB-4M
OLB-5M
OLB-6M
OLB-7M
OLB-8M
OLB-9M
OLB-0M
OLB-1
OLB-2
OLB-3
OLB-4
OLB-5
OLB-6
OLB-7
OLB-8
OLB-9
OLB-0
See page F16 for Standard Materials & Finish
4-3/8"(111)
4-29/32"(125)
5-23/32"(145)
6-13/32"(162)
17-3/4"(451)
8-5/32"(207)
11-7/16"(291)
11-7/16"(291)
13-3/4"(349)
13-3/4"(349)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-11/16"(94)
3-11/16"(94)
4-7/8"(124)
4-7/8"(124)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
10-5/8"(270)
10-5/8"(270)
13-1/8"(333)
13-1/8"(333)
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
1-13/16"(46)
2-3/16"(54)
2-1/2"(67)
2-3/4"(70)
4.0
7.0
12.0
32.0
36.0
70.0
142.0
173.0
292.0
324.0
L L T Y P E C O N D U I T B O D Y *
LL Type
LL Type
OLL-1M
OLL-2M
OLL-3M
OLL-4M
OLL-5M
OLL-6M
OLL-7M
OLL-8M
OLL-9M
OLL-0M
OLL-1
OLL-2
OLL-3
OLL-4
OLL-5
OLL-6
OLL-7
OLL-8
OLL-9
OLL-0
4-5/8"(117)
5-3/8"(137)
6-1/4"(159)
8-1/8"(206)
8-1/8"(206)
10-9/16"(268)
13-11/16"(348)
13-11/16"(348)
16-1/2"(419)
16-1/2"(419)
1-3/8"(35)
1-5/8"(41)
2"(51)
2-5/8"(67)
2-3/4"(70)
3-1/2"(89)
4"(102)
4-3/4"(121)
5-1/2"(140)
5-5/8"(143)
2"(51)
2-3/16"(56)
2-9/16"(65)
3-1/2"(89)
3-1/2"(89)
4-3/16"(106)
5-3/4"(146)
5-3/4"(146)
7-1/8"(181)
7-1/8"(181)
—
—
—
—
—
—
—
—
—
—
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY ® 5 SERIES • FITTINGSALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F18
FEATURES-SPECIFICATIONS
See page F16 for Standard Materials & Finish
LR Type T Type
LR Type
T Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-5/8"(117)
5-3/8"(137)
6-1/4"(159)
8-1/8"(206)
8-1/8"(206)
10-9/16"(268)
13-11/16"(348)
13-11/16"(348)
16-1/2"(419)
16-1/2"(419)
1-3/8"(35)
1-5/8"(41)
2"(51)
2-5/8"(67)
2-3/4"(70)
3-1/2"(89)
4"(102)
4-3/4"(121)
5-1/2"(140)
5-5/8"(143)
2"(35)
2-3/16"(67)
2-9/16"(65)
3-1/2"(89)
3-1/2"(89)
4-3/16"(106)
5-3/4"(146)
5-3/4"(146)
7-1/8"(181)
7-1/8"(181)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-11/16"(93)
3-11/16"(93)
4-7/8"(124)
4-7/8"(124)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
10-5/8"(270)
10-5/8"(270)
13-1/8"(333)
13-1/8"(333)
4-3/8"(111)
4-29/32"(125)
5-23/32"(145)
6-13/32"(162)
17-3/4"(451)
9-5/32"(233)
11-7/16"(291)
11-7/16"(291)
13-3/4"(349)
13-3/4"(349)
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
1-13/16"(54)
2-3/16"(54)
2-1/2"(67)
2-3/4"(67)
4.0
7.0
12.0
32.0
36.0
70.0
142.0
173.0
292.0
324.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
L R T Y P E C O N D U I T B O D Y *
A B C D E F G
Dimensions
OLR-1M
OLR-2M
OLR-3M
OLR-4M
OLR-5M
OLR-6M
OLR-7M
OLR-8M
OLR-9M
OLR-0M
OLR-1
OLR-2
OLR-3
OLR-4
OLR-5
OLR-6
OLR-7
OLR-8
OLR-9
OLR-0
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/8"(137)
6-1/16"(154)
7-1/8"(181)
9-3/16"(233)
9-3/16"(233)
11-5/8"(295)
15-1/8"(384)
15-1/8"(384)
18-1/8"(460)
18-1/8"(460)
1-3/8"(35)
1-5/8"(41)
2"(51)
2-5/8"(67)
2-3/4"(70)
3-1/2"(89)
4"(102)
4-3/4"(121)
5-1/2"(140)
5-5/8"(143)
2"(35)
2-3/16"(67)
2-9/16"(65)
3-1/2"(89)
3-1/2"(89)
4-3/16"(106)
5-3/4"(146)
5-3/4"(146)
7-1/8"(181)
7-1/8"(181)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-11/16"(94)
3-11/16"(94)
4-7/8"(124)
4-7/8"(124)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
10-5/8"(270)
10-5/8"(270)
13-1/8"(333)
13-1/8"(333)
—
—
—
—
—
—
—
—
—
—
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
1-13/16"(54)
2-3/16"(54)
2-1/2"(67)
2-3/4"(67)
4.0
7.0
12.0
32.0
36.0
70.0
142.0
173.0
292.0
324.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
T T Y P E C O N D U I T B O D Y *
A B C D E F G
OT-1M
OT-2M
OT-3M
OT-4M
OT-5M
OT-6M
OT-7M
OT-8M
OT-9M
OT-0M
OT-1
OT-2
OT-3
OT-4
OT-5
OT-6
OT-7
OT-8
OT-9
OT-0
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY ® 5 SERIES • FITTINGSALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F19
FEATURES-SPECIFICATIONS
FSee page F16 for Standard Materials & Finish
Dimensions
X TypeTB Type
TA Type
TB Type
X Type
OTA-1M
OTA-2M
OTA-3M
OTA-1
OTA-2
—
1/2"
3/4"
1"
2"(51)
2-3/16"(56)
2-9/16"(65)
5-3/8"(137)
6-1/16"(154)
7-1/8"(181)
1"(25)
1-7/32"(29)
1-15/32"(35)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
—
—
—
5/8"(16)
3/4"(19)
15/16"(24)
4.0
7.0
12.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
TA T Y P E C O N D U I T B O D Y *
A B C D E F G
2-1/8"(54)
2-15/16"(75)
2-11/16"(68)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-3/8"(137)
6-1/16"(160)
7-1/8"(181)
9-3/16"(233)
9-3/16"(233)
11-5/8"(295)
2-1/8"(54)
2-5/16"(59)
2-11/16"(68)
3-9/16"(90)
3-3/4"(92)
4-5/8"(117)
1-5/16"(33)
1-9/16"(40)
1-13/16"(46)
2-1/2"(64)
2-1/2"(64)
3-1/8"(79)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(35)
1-5/8"(41)
4 .0
7.0
12.0
32.0
36.0
70.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONS VOLUMECU. IN.
T B T Y P E C O N D U I T B O D Y *
A B C D E F G
OTB-1M
OTB-2M
OTB-3M
OTB-4M
OTB-5M
OTB-6M
OTB-1
OTB-2
OTB-3
OTB-4
OTB-5
OTB-6
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-3/8"(137)
6-1/16"(160)
7-1/8"(181)
9-3/16"(233)
9-3/16"(233)
11-5/8"(295)
1-3/4"(44)
2"(51)
2-1/4"(57)
2-9/16"(65)
2-3/4"(70)
3-3/8"(85)
1-11/16"(43)
2-7/8"(73)
3-3/8"(86)
4-1/2"(114)
4-1/2"(114)
5-1/4"(133)
1"(25)
1-7/32"(31)
1-15/32"(37)
2"(51)
2"(51)
2-9/16"(65)
3-5/32"(80)
3-25/32"(96)
4-17/32"(115)
6"(152)
6"(152)
8-1/16"(205)
—
—
—
—
—
—
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(35)
1-5/8"(41)
4 .0
7.0
12.0
32.0
36.0
70.0
HUB SIZEKILLARK
ALUM.DURALOYIRON
CATALOG NUMBER DIMENSIONSVOLUMECU. IN.
X T Y P E C O N D U I T B O D Y *
A B C D E F G
OX-1M
OX-2M
OX-3M
OX-4M
OX-5M
OX-6M
OX-1
OX-2
OX-3
OX-4
OX-5
OX-6
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D/A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
TA Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY ® 5 SERIES • FITTINGSCOVERS AND GASKETS
F20
FEATURES-SPECIFICATIONS
A L U M I N U M A N D S T E E L S TA M P E D C O V E R S
Fiber Gasket
DIMENSIONS
C A S T I R O N C O V E R S
OL-10CM
OL-20CM
OL-30CM
OL-45CM
OL-45CM
OL-60CM
OL-78CM
OL-78CM
OL-90CM
OL-90CM
3-15/16"(100)
4-5/8"(117)
5-3/8"(137)
7-3/16"(183)
7-3/16"(183)
9-1/2"(241)
12-1/4"(311)
12-1/4"(311)
14-7/8"(378)
14-7/8"(378)
3-15/16"(100)
4-5/8"(117)
5-3/8"(137)
7-3/16"(183)
7-3/16"(183)
9-1/2"(241)
12-1/4"(311)
12-1/4"(311)
14-7/8"(378)
14-7/8"(378)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
WIDTH3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
HEIGHT
DIMENSIONS
LENGTH WIDTH HEIGHT
FIBERHUBSIZE
OLK-1VG
OLK-2VG
OLK-3VG
OL-45-VG
OL-45-VG
OL-6-VG
OL-78-VG
OL-78-VG
OL-90-VG
OL-90-VG
CATALOG NUMBER
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
Cast Material/FinishDuraloy Malleable Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
• 300 Series stainless steel screws
Stamped Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Natural finish
• 300 Series stainless steel screws
Galvanized Steel
• Natural finish
• 300 Series stainless steel screws
Material/Finish• Neoprene or fiber
CATALOG NUMBER
HUB SIZE
HUB SIZE
G A S K E T S
OLK-1RG
OLK-2RG
OLK-3RG
OL-45-RG
OL-45-RG
OL-6-RG
OL-78-RG
OL-78-RG
OL-90-RG
OL-90-RG
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted F i le No. E3397
Cer t i f i ed F i le No. LR11852
3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
Cast Iron Covers
NEOPRENE
Neoprene Gasket
CATALOG NUMBERKILLARKALUMINUM STEEL
Aluminum and Steel Stamped Covers
OL-10M
OL-20M
OL-30M
OL-45M
OL-45M
OL-60M
OL-78M
OL-78M
OL-90M
OL-90M
OL-10
OL-20
OL-30
OL-450
OL-450
OL-60
OL-780
OL-780
OL-900
OL-900
TWO SERIES • FITTINGSALUMINUM CONDUIT BODIES
F21
FEATURES-SPECIFICATIONS
FApplications• For use with E.M.T conduit thin wall
• To make bends in the conduit system
• Connect conduit sections
• Provide access to the conduit system
• As a pulling outlet
• Provide openings for taps or splices
Features• Easy installation (screwdriver is
only tool required)
• Complete selection of sizes andhub configurations
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
• Aluminum and steel/iron type 5 covers and gaskets can be usedwith TW series bodies. See page F23
LISTED - F ILE E3397
CERTIF IED - F ILE LR11852
See f i les for de ta i ls or ca l l K i l la rk .TWOC Type TWOLB Type
1/2"
3/4"
1"
5-3/16"(132)
5-3/4"(146)
7-1/16"(179)
15/16"(24)
1-1/2"(38)
1-3/4"(44)
1-5/16"(33)
2-5/16"(59)
1-3/4"(44)
1-1/8"(29)
1-3/16"(30)
1-1/2"(38)
3-1/2"(89)
4-1/8"(105)
4-7/8"(124)
—
—
—
5/8"(16)
3/4"(19)
7/8"(22)
4.0
7.0
12.0
HUB SIZE
CATALOG NUMBER
DIMENSIONS VOLUMECU. IN.
T W O C T Y P E C O N D U I T B O D Y
A B C D E F G
TWOC-1
TWOC-2
TWOC-3
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-1/2""(114)
5-3/16"(132)
6-1/4"(159)
8-1/16"(205)
8-1/16"(205)
10"(283)
13"(330)
13"(330)
15-3/4"(400)
15-3/4"(400)
1-5/16"(33)
1-1/2"(38)
1-3/4"(44)
2-1/2"(64)
2-1/2"(64)
3-1/8"(79)
4-7/16"(113)
4-7/16"(113)
5-1/2"(140)
5-1/2"(140)
2-9/32"(58)
2-9/16"(41)
3-3/32"(79)
3-3/4"(95)
4"(102)
4-11/16"(119)
6-1/4"(159)
6-1/4"(159)
7-15/32"(190)
7-15/32"(190)
1-1/8"(29)
1-5/i6"(33)
1-9/16"(40)
2-1/4"(51)
2-1/4"(51)
2-7/8"(73)
4-1/16"(103)
4-1/16"(103)
5-3/16"(132)
5-3/16"(132)
3-1/2"(89)
4-1/8"(105)
4-7/8"(124)
6-1/2"(165)
6-1/2"(165)
8-9/16"(217)
11-1/4"(286)
11-1/4"(286)
13-3/4"(349)
13-3/4"(349)
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
1-13/16"(54)
2-3/16"(54)
2-1/2"(67)
2-3/4"(67)
4.0
7.0
12.0
32.0
36.0
70.0
142.0
173.0
292.0
324.0
HUB SIZE
CATALOG NUMBER
DIMENSIONS VOLUMECU. IN.
T W O L B T Y P E C O N D U I T B O D Y
A B C D E F G
TWOLB-1
TWOLB-2
TWOLB-3
TWOLB-4
TWOLB-5
TWOLB-6
TWOLB-7
TWOLB-8
TWOLB-9
TWOLB-0
3-5/32"(80)
3-3/4"(95)
4-1/2"(114)
6-1/16"(154)
6-1/16"(154)
8-1/8"(206)
10-1/2"(267)
10-1/2"(267)
13-1/4"(337)
13-1/4"(337)
LB Type C Type
Dimensions
TWO SERIES • FITTINGSALUMINUM CONDUIT BODIES
F22
FEATURES-SPECIFICATIONS
TWOT TypeTWOLRL Type
LISTED - F ILE E3397
CERTIF IED - F ILE LR11852
See f i les for de ta i ls or ca l l K i l la rk .
CONDUITSIZE A B C D E F G
1/2"4-1/2" 1-5/16" 3-1/8" 1-1/8" 3-1/2" 2-3/16"(114) (33) (79) (29) (89) (56)
3/4"5-3/16" 1-1/2" 3-3/4" 1-1/4" 4-1/8" 2-5/16"(132) (38) (95) (32) (105) (59)
1"6-1/4" 1-3/4" 4-1/2" 1-9/16" 4-7/8" 2-13/16"(159) (44) (114) (40) (124) (71)
T W O L R L T Y P E C O N D U I T B O D Y
TWOLRL-1
TWOLRL-2
TWOLRL-3
CATALOG NUMBER
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-3/16"(132)
5-3/4"(146)
7"(178)
8-11/16"(221)
8-1/8"(206)
10"(254)
15/16"(24)
1-1/2"(38)
1-3/4"(44)
2-1/2"(64)
2-1/2"(64)
3-1/8"(79)
2-1/4(57)
2-5/16"(59)
3"(76)
3-1/2"(89)
3-3/8"(86)
3-3/4"(95)
1-1/8"(29)
1-3/16"(30)
1-9/16"(40)
2-3/16"(56)
2-3/16"(56)
2-3/4"(70)
3-1/2"(89)
4-1/8"(105)
4-7/8"(124)
6-1/2"(165)
6-1/2"(165)
8-5/8"(219)
5/8"(16)
3/4"(19)
15/16"(24)
1-3/16"(30)
1-3/8"(32)
1-5/8"(38)
—
—
—
—
—
—
4.0
7.0
12.0
32.0
36.0
70.0
HUB SIZE
CATALOG NUMBER
DIMENSIONS VOLUMECU. IN.
VOLUMECU. IN.
T W O T T Y P E C O N D U I T B O D Y
A B C D E F G
TWOT-1
TWOT-2
TWOT-3
TWOT-4
TWOT-5
TWOT-6
LR Type T Type
Dimensions
Applications• For use with E.M.T conduit thin wall
• To make bends in the conduit system
• Connect conduit sections
• Provide access to the conduit system
• As a pulling outlet
• Provide openings for taps or splices
Features• Easy installation (screwdriver is
only tool required)
• Complete selection of sizes andhub configurations
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
• Aluminum and steel/iron type 5 covers and gaskets can be usedwith TW series bodies. See page F23
5/8"(16)
3/4"(19)
7/8"(22)
4 .0
7.0
12.0
TWO SERIES • FITTINGSCOVERS AND GASKETS
F23
FEATURES-SPECIFICATIONS
F
OLK series have perforated center area, removable for use with device covers.
*Armstrong type CS-301.
T W O C O V E R S A N D G A S K E T S
Covers furnished with stainless steel set screws.
BODYSIZE
1/2"
3/4"
1"
1-1/4 – 1-1/2
2"
2-1/2" – 3"
3-1/2" – 4"
SHEETALUMINUM
OL-10
OL-20
OL-30
OL-450
OL-60
OL-780
OL-900
PLANTFIBER*
OLK-1VG
OLK-2VG
OLK-3VG
OL-45-VG
OL-6-VG
OL-78-VG
OL-90-VG
NEOPRENERUBBER
OLK-1RG
OLK-2RG
OLK-3RG
OL-45-RG
OL-6-RG
OL-78-RG
OL-90-RG
CATALOG NUMBERGASKET
CATALOG NUMBERBLANK COVER
Fiber Gasket Neoprene GasketStamped Aluminum Covers
MO SERIES • FITTINGSIRON AND ALUMINUM MOGUL CONDUIT BODIES
F24
FEATURES-SPECIFICATIONS
LB TYPE C TYPE
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10, and 503.10.
Lis ted
Cer t i f i ed
Applications• Mogul fittings are for use with rigid and IMC
raceways
• Use where standard conduit bodies do not pro-vide adequate access and wiring area for thepulling of large and heavy conductors
• For right angle bends where splices, pulls andtaps are needed in a weather-proof chamber
Features• A raised dome cover permits additional wiring
room
• Furnished with captive ss screws and gasket
• LBD, C and UB Series available with built-incable-pulling rollers on sizes 1-1/2” and larger.Add -WR to catalog number. Example MOLBD-5-WR.
Material/Finish
• Cast iron moguls are hot dipped galvanized
• Aluminum moguls are of copper-free aluminum(less than 4/10 of 1%) with electrostaticallyapplied powder coating
HUB SIZE
CATALOG NUMBER
L B T Y P E M O G U L C O N D U I T B O D Y
5"(127)
6-1/4"(159)
9-5/8"(244)
9-5/8"(244)
14-7/16"(367)
14-7/16"(367)
22"(559)
22"(559)
28-1/2"(724)
28-1/2"(724)
2-5/16"(59)
2-5/8"(67)
3-5/8"(92)
3-5/8"(92)
5-5/8"(143)
5-5/8"(143)
7-1/2"(191)
7-1/2"(191)
9-1/4"(235)
9-1/4"(235)
1-5/16"(33)
1-9/16"(40)
2-1/2"(64)
2-1/2"(64)
3"(76)
3"(76)
4-1/2"(114)
4-1/2"(414)
5-1/2"(140)
5-1/2"(140)
3"(76)
4-1/2"(114)
7-1/2"(191)
7-1/2"(191)
12"(305)
12"(305)
18"(457)
18"(457)
24"(610)
24"(610)
MOLBD-1M
MOLBD-2M
MOLBD-3M
MOLBD-4M
MOLBD-5M
MOLBD-6M
MOLBD-7M
MOLBD-8M
MOLBD-9M
MOLBD-0M
MOLBD-1
MOLBD-2
MOLBD-3
MOLBD-4
MOLBD-5
MOLBD-6
MOLBD-7
MOLBD-8
MOLBD-9
MOLBD-0
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLEDHEIGHT
WIDTH 6X LENGTHKILLARKALUM.
KILLARKIRON
HUB SIZE
CATALOG NUMBER
C T Y P E M O G U L C O N D U I T B O D Y
12"(305)
12-1/16"(306)
18-1/8"(460)
18-1/16"(459)
27-1/8"(689)
27-1/4"(692)
35-3/8"(899)
35-7/16"(900)
3"(76)
3-5/16"(84)
3-7/8"(98)
4-7/16"(113)
5-3/16"(132)
5-15/16"(151)
7-3/16"(183)
7-9/16"(192)
2-5/8"(67)
2-5/8"(67)
3-3/16"(81)
3-3/16"(81)
4-11/16"(119)
4-11/16"(119)
5-11/16"(144)
5-11/16"(144)
10"(254)
10"(254)
16"(406)
16"(406)
24"(610)
24"(610)
32"(813)
32"(813)
MOC-3M
MOC-4M
MOC-5M
MOC-6M
MOC-7M
MOC-8M
MOC-9M
MOC-0M
MOC-3
MOC-4
MOC-5
MOC-6
MOC-7
MOC-8
MOC-9
MOC-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLEDHEIGHT
WIDTH 8X LENGTHKILLARKALUM.
KILLARKIRON
C Sizes
LB Sizes 2-1/2” thru 4”
LB Sizes 1” thru 2”
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
MO SERIES • FITTINGSIRON AND ALUMINUM MOGUL CONDUIT BODIES
F25
FEATURES-SPECIFICATIONS
F
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
Lis ted
Cer t i f i ed
T TYPE UB TYPE
HUB SIZE
CATALOG NUMBER
T T Y P E
12"(305)
12-1/16"(306)
18-1/8"(460)
18-1/16"(459)
27-1/8"(689)
27-1/4"(692)
35-3/8"(899)
35-7/16"(900)
3"(76)
3-5/16"(84)
3-7/8"(98)
4-7/16"(113)
5-3/16"(132)
5-15/16"(151)
7-3/16"(183)
7-9/16"(192)
2-5/8"(67)
2-5/8"(67)
3-3/16"(81)
3-3/16"(81)
4-11/16"(119)
4-11/16"(119)
5-11/16"(144)
5-11/16"(144)
10"(254)
10"(254)
16"(406)
16"(406)
24"(610)
24"(610)
32"(813)
32"(813)
MOT-3M
MOT-4M
MOT-5M
MOT-6M
MOT-7M
MOT-8M
MOT-9M
MOT-0M
MOT-3
MOT-4
MOT-5
MOT-6
MOT-7
MOT-8
MOT-9
MOT-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLEDHEIGHT
WIDTH 8X LENGTHKILLARKALUM.
KILLARKIRON
HUB SIZE
CATALOG NUMBER
U B T Y P E
10-7/16"(265)
10-7/16"(265)
15-9/16"(395)
15-9/16"(395)
23-1/16"(586)
23-5/16"(668)
30"(762)
30"(762)
3-7/8"(98)
4-3/16"(106)
5-1/8"(130)
5-3/4"(146)
8-1/2"(216)
8-1/2"(216)
10-3/8"(264)
10-3/8"(264)
2-5/8"(67)
2-5/8"(67)
3-3/16"(81)
3-3/16"(81)
4-11/16"(119)
4-11/16"(119)
5-11/16"(144)
5-11/16"(144)
7-1/2"(191)
7-1/2"(191)
12"(305)
12"(305)
18"(457)
18"(457)
24"(610)
24"(610)
MOUB-3M
MOUB-4M
MOUB-5M
MOUB-6M
MOUB-7M
MOUB-8M
MOUB-9M
MOUB-0M
MOUB-3
MOUB-4
MOUB-5
MOUB-6
MOUB-7
MOUB-8
MOUB-9
MOUB-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLEDHEIGHT
WIDTH 8X LENGTHKILLARKALUM.
KILLARKIRON
See page F24 for Standard Materials & Finish
Dimensions
T Sizes 2-1/2” thru 4”
UB Sizes 1” thru 2”
UB Sizes 2-1/2” thru 4”
T Sizes 1” thru 2”
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
MOL SERIES • FITTINGSMOGUL CONDUIT BODIES
F26
FEATURES-SPECIFICATIONS
Applications• Mogul fittings are normally used
where the standard “O” Series con-duit bodies do not offer a sufficientamount of wiring room
• For right angle bends wheresplices, pulls and taps are neededin a weather-proof chamber
Features• A raised dome cover provides
additional wiring room
• Furnished with cover and gasket
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
M O L C O N D U I T B O D I E S
MOLB-4* 1-1/4" 5/16" 9-3/4" 2-3/4" 8-1/2" 1" 2-3/8" 9-1/8" 2-3/4"(8) (248) (70) (445) (25) (60) (232) (70)
MOLB-5 1-1/2" 1-5/16" 13-3/16" 4-3/4" 11-1/2" 2-3/8" 3-1/8" 12-7/8" 3-3/8"(33) (335) (121) (292) (60) (79) (327) (86)
MOLB-6 2"1-1/16" 13-3/16" 4-1/4" 11-1/2" 2-1/2" 3-1/8" 12-7/8" 3-3/8"(27) (335) (108) (292) (64) (79) (327) (86)
MOLB-6CG* 2"1/16" 14-1/2" 5-3/4" 13" 1-3/8" 3" 14-1/8" 3-5/16"(2) (368) (146) (330) (35) (76) (359) (84)
MOLB-7 2-1/2"1-13/16" 22-5/8" 6-1/4" 20" 3-15/16" 4-7/16" 21-13/16" 4-7/16"(46) (575) (159) (508) (100) (113) (554) (113)
MOLB-8 3"1-13/16" 22-5/8" 6-1/4" 20" 3-15/16" 4-7/16" 21-13/16" 4-7/16"(46) (575) (169) (508) (100) (113) (554) (113)
MOLB-9 3-1/2"1-9/16" 28-11/16" 7-7/8" 25-9/16" 4-3/16" 5-1/2" 28-5/16" 5-1/2"(40) (729) (200) (649) (106) (140) (719) (140)
MOLB-0 4"1-9/16" 28-11/16" 7-7/8" 25-7/16" 4-3/16" 5-1/2" 28-5/16" 5-1/2"(40) (729) (200) (646) (106) (140) (719) (140)
MLB-12* 5"2-3/8" 43-1/4" 12-1/4" 38-5/8" 6-1/4" 9" 42-1/2" 8-11/16"(68) (1099) (311) (981) (159) (229) (1080) (221)
CATALOG CONDUIT DIMENSIONSNUMBER SIZE A B C D E F G J
Dimensions
M O L B L A N K R E P L A C E M E N T C O V E R S A N D G A S K E T S
MOL-450 1-1/4"
MOL-560 1-1/2" & 2"
MOL-6CG 2"
MOL-780 2-1/2" & 3"
MOL-900 3-1/2" & 4"
MOLB-4
CATALOG NUMBER BODY STYLE
*Split cover design
MOLB-6CG MLB-12
MOLB-5 thru 0
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502-.10 and 503.10.
NECLB SERIES • FITTINGS40% FILL CONDUIT BODIES
F27
FEATURES-SPECIFICATIONS
F
NECLB-6
Lis ted - F i le E3397
See f i les for de ta i ls or ca l l K i l la rk .
N E C L B C O N D U I T B O D I E S
Dimensions
Applications• Specially designed to meet
National Electrical Code Article370-28(a) (2) for angle pulls wherethe distance between the racewayentry and the opposite wall of thefitting must be at least six times thetrade diameter of the raceway.
CATALOG REPLACEMENT HUBNUMBER COVER AND GASKET SIZE A B C D E F G H J K
NECLB-3 NECLB-30 1" 8-1/8" 3-7/16" 2" 11-9/32" 6" 2" 1-1/8" 3-1/8" 7" 1 NPT
NECLB-4 NECLB-40 1-1/4" 9-7/8" 4-1/16" 2-3/8" 11-5/16" 7-1/2" 2-1/2" 1-3/16" 3-11/16" 8-5/8" 1-1/4 NPT
NECLB-5 NECLB-50 1-1/2" 11-17/32" 5-1/16" 2-3/4" 2-3/16" 9" 3-1/2" 1-3/16" 4-11/16" 10-5/8" 1-1/2 NPT
NECLB-6 NECLB-60 2" 14-25/32" 6-3/16" 3" 2-11/16" 12" 4" 1-3/16" 5-3/16" 13-11/16" 2 NPT
• A pull box with easy access to conductors
• A chamber with a large openingfor easy access to performchanges in the conduit system
• For 90° bends in a conduit system
• Includes cover and gasket
FeaturesLarge cover opening (length of openingexceeds six times the trade diameterof the hub size) for easy access toconductors. Cover and gasket included
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502-.10 and 503.10.
SLB/SLBM/SOLB/MLB SERIES • FITTINGSSERVICE ENTRANCE • STANDARD AND HOSTILE LOCATIONS
F28
FEATURES-SPECIFICATIONS
Features• Designed for easier wire pulling
• Includes Cover and Gasket
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
Lis ted - F i le E22698
Cer t i f i ed - F i le LR11852
See f i les for de ta i ls or ca l l K i l la rkMLB-12
SOLB-8, 9, 0
CATALOG CONDUITNUMBER SIZE A B C D E F
SLB-1 1/2"2-3/4" 1-1/16" 2-3/8" 3/4" 1-3/8" 1-3/16" (70) (27) (60) (19) (35) (30)
SLB-2 3/4"3-1/8" 1-3/8" 2-11/16" 7/8" 1-11/16" 1-3/8" (79) (35) (68) (22) (43) (35)
SLB-3 1"3-3/4" 1-5/8" 3-1/4" 15/16" 1-15/16" 1-3/4"(95) (41) (83) (24) (49) (44)
SLB-4 1-1/4"5" 2" 4-5/16" 1-1/4" 2-1/2" 2-3/16" (127) (51) (110) (32) (64) (56)
SLBM-4 1-1/4"7-1/4" 1-15/16" 6-3/8" 15/16" 2-5/8" 2-1/2" (184) (49) (162) (24) (67) (64)
SLB-5 1-1/2"5-3/4" 2-7/16" 4-3/4" 1-1/2" 2-9/16" 2-7/16"(147) (62) (121) (38) (65) (62)
SLB-6 2"6-1/4" 2-15/16" 5" 1-5/8" 3-1/8" 2-13/16"(159) (75) (127) (41) (79) (71)
SLBM-6 2"9-1/2" 2-11/16" 8-9/16" 11-3/16" 3-7/16" 3-1/8"(241) (68) (217) (284) (87) (79)
SLB-7 2-1/2"8" 3-9/16" 6-7/8" 11-5/16" 4" 3-1/2"(203) (90) (175) (287) (102) (89)
SOLB-8 3"12-1/4" 4-7/16" 10-7/16" 11-3/16" 6-1/4" 4-7/16"(311) (113) (265) (284) (159) (113)
SOLB-9 3-1/2"15" 5" 11-7/8" 3-1/8" 7-1/2" 5-1/2"(381) (127) (302) (79) (191) (140)
SOLB-0 4"15" 5" 11-7/8" 3-1/8" 7-1/2" 5-1/2"
(381) (127) (302) (79) (191) (140)
MLB-12 5"42-1/2" 8-11/16" 38-5/8" 4-5/8" 12-1/4" 9"
(1080) (221) (981) (118) (311) (229)
S E R V I C E E N T R A N C E B O D I E S
SLB-1 thru 7
SLBM-4
• Suitable for wet locations whenused with gasketed covers.
• Federal Specification W-C-586D / A-A 50563.
• Suitable for use in hazardous loca-tion applications when installedaccording to NEC Articles501.10(b), Class I, Div. 2, (Suitablefor use in Class I Zone 2 applica-tions) 502.10 and 503.10.
WH SERIES • FITTINGSCONDUIT HUBS
F29
FEATURES-SPECIFICATIONS
F
A
1.500"
1.510"
1.812"
1.877"
1.920"
1.895"
2.605"
2.615"
2.570"
2.590"
Lis ted
Cer t i f i ed
W H W E AT H E R P R O O F C O N D U I T H U B S
CATALOG NPTNUMBER HUB SIZE
WH-1 1/2"
WH-2 3/4"
WH-3 1"
WH-4 1-1/4"
WH-5 1-1/2"
WH-6 2"
WH-7 2-1/2"
WH-8 3"
WH-9 3-1/2"
WH-0 4"
D I M E N S I O N S
WH
ApplicationsConduit hubs provide a liquid tight, oiltight and dust tight termination ofelectrical conduit through the walls ofsheet metal enclosures. The hubs fitinto standard knock-out dimensions.
They are also suitable for use in haz-ardous locations per National ElectricalCode (Articles 501-4(b), 502-4(a&b),503-3(a&b) and 505-15 (c).
Features• Oversized locknut provides for a
strong vibration-proof termination
• Captive sealing ring
• Serrations on hub body and locknutprovide effective positive groundpath
• Rugged cast zinc construction
• Insulated throat protects conductors
• Suitable for use with NEMA typeenclosures 2, 3, 3R, 4, 12 and 13
Material/Finish• Die cast zinc
• Natural finish
• Sealing ring - Buna-N
A
B
“C”NPSM-2AThread
CATALOGNUMBER
WH-1
WH-2
WH-3
WH-4
WH-5
WH-6
WH-7
WH-8
WH-9
WH-0
B
1.437"
1.685"
1.921"
2.370"
2.745"
3.236"
3.708"
4.370"
4.941"
5.450"
C
1/2"-14
3/4"-14
1"-11-1/2
1-1/4"-11-1/2
1-1/2"-11-1/2
2"-11-1/2
2-1/2"-8
3"-8
3-1/2"-8
4"-8
CL/CLM/SOLB/TWCL/DS SERIES • FITTINGSPULLING ELBOW & DUST SEAL • STANDARD AND HOSTILE LOCATIONS
F30
FEATURES-SPECIFICATIONS
Lis ted - F i leE E22699
Cer t i f i ed - F i le LR11852
See f i les for de ta i ls or ca l l K i l la rk .TWCL-2
CATALOG HUB NUMBER SIZE TYPE
CL-1 1/2"
CL-2 3/4" CL
CL-3 1"
CLM-1 1/2"
CLM-2 3/4" CLM
CLM-3 1"
P U L L I N G E L B O W S F O R T H R E A D E D C O N D U I T
1Raintight/concrete tight
2Set screw in each hub
CATALOG HUBNUMBER SIZE
TWCL-1 1/2"
TWCL-2 3/4"
P U L L I N G E L B O W SF O R T H I N W A L L C O N D U I T2
CATALOGNUMBER SIZE
DS-1 1- lb .
DS-5 5- lb .
Duct Seal is a soft, non-hardeningweather-proof compound, easilyapplied in all working temperatures. It is non-staining, can be painted, is an excellent moisture barrier forweather-sealing service entries, electrical cables, conduit ducts, etc.
Applications• 90° pulling elbows are used to
accommodate pulling conductorsthrough a sharp bend in the con-duit system
Features• Designed for easier wire pulling
• Includes Cover and Gasket
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
CLM-21
CL-3
Duct Seal
SIZE A B C D E
1/2" 1-1/4" (32) 2-9/16" (65) 1-3/8" (35) 1-1/4" (32) 1-7/16" (37)
3/4" 1-3/8" (35) 2-3/4" (70) 1-9/16" (40) 1-3/8" (35) 1-17/32" (39)
1" 1-3/4" (44) 3-1/8" (79) 1-3/4" (44) 1-3/4" (44) 1-23/32" (44)
D I M E N S I O N S
D U C T S E A L
FB/STFB SERIES • FITTINGSSERVICE ENTRANCE • STANDARD AND HOSTILE LOCATIONS
F31
FEATURES-SPECIFICATIONS
F
Lis ted - F i le E22698
See f i les for de ta i ls or ca l l K i l la rk .
CATALOG HUB KNOCKOUTS DIMENSIONSNUMBER SIZE QUANTITY DIAMETER WIDTH HEIGHTFB-714 1/2" 4 3/8” 3.00" (76) 2 .60" (66)
FB-724 3/4" 5 3/8” 2.39" (61) 2 .32" (58)
FB-734 1" 5 1/2” 2.62" (67) 3 .03" (80)
FB-745 1-1/4" 5 1/2” 2.62" (67) 3 .03" (80)
One 1/2”
FB-765 2" 6 Two 3/4” 4.43" (113) 4 .45" (113)
Three 1”
FB-787 3" 7Four 1”
6 .40" (163) 8.00" (203)Three 1-1/4”
FB-707 4" 7Four 1-1/4”
8.00" (163) 9.00" (229)Three 1-3/4”
F B S E R V I C E E N T R A N C E
CATALOG HUB KNOCKOUTS DIMENSIONSNUMBER SIZE QUANTITY DIAMETER WIDTH HEIGHTSTFB-2 3/4" 5 3/8” 2.39" (61) 2 .32" (59)
STFB-3 1" 5 1/2” 2.62" (67) 3 .03" (77)
STFB-4 1-1/4" 5 1/2” 2.62" (67) 3 .03" (77)
One 1/2”
STFB-5 1-1/2" 6 Two 5/8” 3.43" (87) 3 .75" (95)
Three 3/4”
One 1/2”
STFB-6 2" 6 Two 3/4” 4.43" (113) 4 .45" (113)
Three 1”
STFB-7 2-1/2" 7Four 1”
6 .40" (163) 8 .00" (203)Three 1-1/4”
STFB-8 3" 7Four 1”
6 .40" (163) 8.00" (203)Three 1-1/4”
STFB-0 4" 7 Four 1-1/4" 8 .00" (203) 9 .00" (229)
S T F B S E R V I C E E N T R A N C E For rigid or thinwall conduit (EMT)
Applications• For overhead service entrance
• For use with EMT or rigid conduit
Features• For use with aluminum or steel
conduit
• Mounting clamp provides easy installation
• Insulators included
• Three point balance for proper alignment
• Variety of knockout arrangements
• Vertical mounting
• Sizes 3/4" thru 4" available
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Natural finish
FB STFB
Weather-proof for threaded conduit.
Applications• For overhead service entrance
• For use with threaded rigid conduit
Features• For use with aluminum or steel
conduit
• Insulators included
• Easy installation and assembly
• Variety of knockout arrangements
• Vertical mounting
• Sizes 1/2" thru 4" available
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Natural finish
FS/FD/FSC SERIES • FITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F32
FEATURES-SPECIFICATIONS
HUB SIZE
VOLUMECU. IN.
F S T Y P E C A S T D E V I C E B O X – S H A L L O W – D E A D E N D
7/8"(22)
7/8"(22)
7/8"(22)
2"(51)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
2-1/8"(54)
2-1/8"(54)
2-1/8"(54)
—
—
—
18.0
18.0
18.0
1/2"
3/4"
1"
A B C D E F G
DIMENSIONS
VOLUMECU. IN.
F D T Y P E C A S T D E V I C E B O X – D E E P – D E A D E N D
7/8"(22)
7/8"(22)
7/8"(22)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
11/16"(17)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
2-1/8"(54)
2-1/8"(54)
2-1/8"(54)
—
—
—
28.0
28.0
28.0
FD-1M
FD-2M
FD-3M
FD-1
FD-2
FD-3
1/2"
3/4"
1"
A B C D E F G
DIMENSIONS
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Optional mounting feet availableon FS, FD, FSC, and FDC
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concrete use
• For use with FS-style covers seepages F41-F43
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
FD - 1 & 2
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852FS 1 & 2 with Lugs FD 1 & 2 with lugs
Dimensions
CATALOG NUMBERKILLARKALUM.
DURALOYIRON
FS-1M
FS-2M
FS-3M
FS-1
FS-2
FS-3
CATALOG NUMBERHUB SIZEKILLARK
ALUM.DURALOYIRON
FS - 1 & 2
FSC 1 & 2 with lugs
VOLUMECU. IN.
F S C T Y P E C A S T D E V I C E B O X – S H A L L O W – F E E D T H R U
7/8"(22)
7/8"(22)
7/8"(22)
2"(51)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
2-1/8"(54)
2-1/8"(54)
2-1/8"(54)
5-3/8"(136)
5-3/8"(136)
5-3/8"(136)
18.0
18.0
18.0
FSC-1M
FSC-2M
FSC-3M
FSC-1
FSC-2
FSC-3
1/2"
3/4"
1"
A B C D E F G
DIMENSIONS
FSC
CATALOG NUMBERHUB SIZEKILLARK
ALUM.DURALOYIRON
FDC/FSOC/FSL SERIES • FITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F33
FEATURES-SPECIFICATIONS
FApplications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Optional mounting feet availableon FS, FD, FSC, and FDC
• Available single and two gang styles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concrete use
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F D C T Y P E C A S T D E V I C E B O X – D E E P – F E E D T H R U
7/8"(22)
7/8"(22)
7/8"(22)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
11/16"(17)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
2-7/8"(73)
2-1/8"(54)
2-1/8"(54)
2-1/8"(54)
5-3/8"(136)
5-3/8"(136)
5-3/8"(136)
28.5
28.5
28.5
FDC-1M
FDC-2M
FDC-3M
FDC-1
FDC-2
FDC-3
1/2"
3/4"
1"
A B C D E F G
DIMENSIONS
FDC 1 & 2 with lugs FSOC Type
FDC - 1 & 2 FSOC
KILLARKALUM.
DURALOYIRON
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S L T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSL-1M
FSL-2M
FSL-1
FSL-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
FSL
FSL Type
KILLARKALUM.
DURALOYIRON
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S O C T Y P E C A S T D E V I C E O P E N B O X – S H A L L O W – F E E D T H R U
7/8"(22)
3"(76)
1-1/2"(138)
4-5/8"(117)
2-7/8"(73)
— — 29.0FSOC-1
A B C D E F G
DIMENSIONS
1/2"
KILLARKALUMINUM
Dimensions
FRS/FST SERIES • FITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F34
FEATURES-SPECIFICATIONS
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Optional mounting feet availableon FS, FD, FSC, and FDC
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concreteuse
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
Dimensions
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S R T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSR-1M
FSR-2M
FSR-1
FSR-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S T T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FST-1
FST-2
FST-1-1M
FST-2-2M
1/2"
3/4"
A B C D E F G
DIMENSIONS
FSR FST
FSR Type FST Type
KILLARKALUM.
DURALOYIRON
KILLARKALUM.
DURALOYIRON
FSX/FSA/FDA/FSLB SERIES • FITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F35
FEATURES-SPECIFICATIONS
FF S X T Y P E C A S T D E V I C E B O X – S H A L L O W
CATALOG NUMBER DIMENSIONS
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
FSX FSA FDA FSLB
FSX Type
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Optional mounting feet availableon FS, FD, FSC, and FDC
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concreteuse
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
KILLARKALUM.
DURALOYIRON
1/2"
3/4"
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
—
—
—
—
—
—
—
—
18.0
18.0
B C D E F GVOLUMECU. IN.
HUB SIZE A
FSX-1M
FSX-2M
FSX-1
FSX-2
Dimensions
FSA/FDA Types FSLB Type
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S A T Y P E C A S T D E V I C E B O X – S H A L L O W – D E A D E N D
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
18.0
18.0
FSA-1
FSA-2
A B C D E F G
DIMENSIONS
1/2"
3/4"
KILLARKALUMINUM
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F D A T Y P E C A S T D E V I C E B O X – D E E P – D E A D E N D
7/8"(22)
2-7/8"(73)
11/16"(17)
4-5/8"(117)
2-7/8"(73)
28.5FDA-2
A B C D E F G
DIMENSIONS
3/4"
KILLARKALUMINUM
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S L B T Y P E C A S T D E V I C E B O X – S H A L L O W – F E E D T H R U
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
18.0
18.0
FSLB-1
FSLB-2
A B C D E F G
DIMENSIONS
1/2"
3/4"
KILLARKALUMINUM
— —
FSS/FSCC/FDCC SERIES • FITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F36
FEATURES-SPECIFICATIONS
Dimensions
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concreteuse
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied
powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
FSS Type FSCC/FDCC Types
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S S T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSS-1M
FSS-2M
FSS-1
FSS-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S C C T Y P E C A S T D E V I C E B O X - S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSCC-1M
FSCC-2M
FSCC-1
FSCC-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F D C C T Y P E C A S T D E V I C E B O X – D E E P
7/8"(22)
2-7/8"(73)
11/16"(17)
4-5/8"(117)
2-7/8"(73)
— — 28.5FDCC-2 FDCC-2M 3/4"
A B C D E F G
DIMENSIONS
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
KILLARKALUM.
DURALOYIRON
KILLARKALUM.
DURALOYIRON
FSCC FDCCFSS
KILLARKALUM.
DURALOYIRON
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F D S T Y P E C A S T D E V I C E B O X
7/8"(22)
2-7/8"(73)
11/16"(17)
4-5/8"(117)
2-7/8"(73)
— — 18.0FDS-2 FDS-2M 3/4"
A B C D E F G
DIMENSIONS
KILLARKALUM.
DURALOYIRON
FSCA/FSCT SERIES • F ITTINGS CAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F37
F
FEATURES-SPECIFICATIONS
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concreteuse
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S C A T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSCA-1M
FSCA-2M
FSCA-1
FSCA-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
F S C T T Y P E C A S T D E V I C E B O X – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
2-7/8"(73)
2-7/8"(73)
—
—
—
—
18.0
18.0
FSCT-1M
FSCT-2M
FSCT-1
FSCT-2
1/2"
3/4"
A B C D E F G
DIMENSIONS
FSCT Type FSCA Type
FSCTFSCA
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
KILLARKALUM.
DURALOYIRON
KILLARKALUM.
DURALOYIRON
Dimensions
2FS/2FD SERIES • F ITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F38
FEATURES-SPECIFICATIONS
2FS Type 2FD Type 2FSC Type
2FS 2FD 2FDC2FSC
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
2 F S T Y P E C A S T D E V I C E B O X T W O G A N G – S H A L L O W
7/8"(22)
7/8"(22)
7/8"(22)
2"(51)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-5/8"(117)
4-11/16"(119)
4-11/16"(119)
4-11/16"(119)
—
—
—
—
—
—
32.0
32.0
32.0
2FS-1M
2FS-2M
2FS-3M
2FS-1
2FS-2
2FS-3
1/2"
3/4"
1"
A B C D E F G
DIMENSIONS
2 F D T Y P E C A S T D E V I C E B O X T W O G A N G – D E E P
7/8"(22)
7/8"(22)
2-15/16"(75)
2-15/16"(75)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-11/16"(119)
4-11/16"(119)
—
—
—
—
47.0
47.0
2FD-1M
2FD-2M
2FD-1
2FD-2
1/2"
3/4"
2 F D C T Y P E C A S T D E V I C E B O X T W O G A N G – D E E P
7/8"(22)
7/8"(22)
2-15/16"(75)
2-15/16"(75)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-11/16"(119)
4-11/16"(119)
—
—
—
—
50.0
50.0
2FDC-1M
2FDC-2M
2FDC-1
2FDC-2
1/2"
3/4"
2 F S D T Y P E C A S T D E V I C E B O X T W O G A N G – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-11/16"(119)
4-11/16"(119)
—
—
—
—
50.0
50.0
2FSD-1M
2FSD-2M
2FSD-1
2FSD-2
1/2"
3/4"
2 F S C T Y P E C A S T D E V I C E B O X T W O G A N G – S H A L L O W
7/8"(22)
7/8"(22)
2"(51)
2"(51)
11/16"(17)
11/16"(17)
4-5/8"(117)
4-5/8"(117)
4-11/16"(119)
4-11/16"(119)
—
—
—
—
32.0
32.0
2FSC-1M
2FSC-2M
2FSC-1
2FSC-2
1/2"
3/4"
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Tapered threads (NPT with integral
bushings)
• Internal grounding screw
• Available single and two gang styles
• Suitable for use in wet locationswhen used with gasket covers
• Cast iron is suitable for concreteuse
• For use with FS-style covers seepages F41-F43
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-coat finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
KILLARKALUM.
DURALOYIRON
2FDC Type
Dimensions
2FSD Type
2 & 3 FS/FD SERIES • F ITTINGSCAST DEVICE BOXES • STANDARD AND HOSTILE LOCATIONS
F39
FEATURES-SPECIFICATIONS
FF S / F D M U LT I G A N G B O X E S 1
Two Gang
2FS 2FD 3FS 3FD
Three Gang
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• Internal grounding screw
• Available single and two gangstyles
• Suitable for use in wet locationswhen used with gasket covers
• For use with FS-style covers seepages F41-F43
Conduit Opening Data• To specify conduit openings select
the letter on these sketches whichindicates the position desired.Follow this letter with the symbolindicating the type and size.
Example: 2FS-A2-E2
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
1 Union hubs are supplied by using a drilled and tapped opening with GUM Series union on 1/2",3/4", 1", 1-1/4" and 1-1/2" sizes.
Two Gang Three GangSingle Gang
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
FOR UNION1CONDUIT THREADED SYMBOLSIZE SYMBOL NUMBER NUMBER
F S / F D / F S Q / F D Q C O N D U I T O P E N I N G A N D S Y M B O L I D E N T I F I C AT I O N
SERIES A B C D E H
FSQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2"(51)
2FS 6-3/16"(157) 3-3/4"(95) 9/32"(7) 4-7/8"(124) 4-15/16"(125) 2"(51)
3FS 6-3/16"(157) 5-3/4"(146) 9/32"(7) 4-7/8"(124) 6-3/4"(125) 2"(51)
FDQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2-7/8"(73)
2FD 6-3/16"(157) 3-3/4"(95) 9/32"(7) 4-7/8"(124) 4-15/16"(125) 2-7/8"(73)
3FD 6-3/16"(157) 5-3/4"(146) 9/32"(7) 4-7/8"(124) 6-3/4"(125) 2-7/8"(73)
FSQ/FDQ SERIES • F ITTINGSCUSTOM DRILLED & TAPPED DEVICE BOXESSTANDARD AND HOSTILE LOCATIONS
F40
FEATURES-SPECIFICATIONS
Lis ted - F i le E3397
Cer t i f i ed - F i le LR11852
See f i les for de ta i ls or ca l l K i l la rk .
FDQ 2FDQ
F S Q / F D Q D R I L L E D A N D TA P P E D D E V I C E B O X E S
SERIES A B C D E H
FSQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2"(51)
2FSQ 5-7/8"(149) 4-1/4"(108) 5/16"(8) 4-7/8"(124) 6-7/16"(164) 2"(51)
3FSQ 5-7/8"(149) 7-9/16"(192) 5/16"(8) 4-15/16"(125) 9-13/16"(249) 2-7/8"(73)
FDQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2-7/8"(73)
2FDQ 6-3/16"(157) 4-7/16"(113) 5/16"(8) 4-7/8"(124) 6-7/16"(164) 2-7/8"(73)
3FDQ 5-7/8"(149) 7-9/16"(192) 5/16"(8) 4-15/16"(125) 9-13/16"(249) 2-7/8"(73)
4FDQ 5-7/8"(149) 10-13/16"(275) 5/16"(8) 4-15/16"(125) 13-1/8"(333) 2-7/8"(73)
• To specify conduit opening combi-nation select the letter on thesketch which indicates the positionof the opening desired. Follow thisletter with the symbol indicating thetype of opening-threaded, thread-less or union
Maximum Conduit Opening SizeFS-1/2" thru 1"FD-1/2" thru 1-1/2"
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
Conduit Opening Data• To specify conduit openings selet
the letter on these sketches whichindicates the position desired.Follow this letter with the symbolindicating the type and size.
Example: 2FS-A2-E2-J13• All conduit openings will be evenly
spaced. When they are to be moreaccurately located, submit a sketchwith spacing dimensions.
• Dimensions should be orientedfrom centerlines of body and out-side backof body.
• FS and FSQ box will take drilledand tapped openings thru 1".
• FD and FDQ box will take drilledand tapped openings thru 1-1/2".
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
FOR CONDUIT THREADED UNION1SIZE SYMBOL NUMBER SYMBOL NUMBER
FS/FD/FSQ/FDQ CONDUIT OPENING AND SYMBOL IDENTIFICATION
1 Union hubs are supplied by using a drilledand tapped opening with GUM Series unionon 1/2", 3/4", 1", 1-1/4" and 1-1/2" sizes.
Two Gang Three Gang Four GangSingle Gang
3FDQ
Three GangTwo GangSingle Gang Four Gang
4FDQ
Applications• Accommodates wiring devices and
provides opening to splice, tap, orpull conductors
• Provide access to conductors formaintenance and future systemchanges
Features• The fittings on this page takes single
gang covers listed on pages F41-F43
• FSQ and FDQ series boxes aremade with individual cover openingsso any combination of devices maybe assembled
• Any assembly is suitable for wetand damp locations when it con-sists of these boxes and a coversuitable for wet and damp locations
FS/FD SERIES • F ITTINGSDEVICE BOX COVERS • STANDARD AND HOSTILE LOCATIONS
F41
FEATURES-SPECIFICATIONS
FS I N G L E G A N G
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR118521FA Type 1FB Type 2FT Type
• Stamped metallic covers with or without electrostatically applied powder coating
• Gaskets to be ordered separately
CATALOG NUMBERWITH WITHOUT
COATING COATING
Blank for Single GangBoxes
1FBC 1FB
1 Toggle Switch
1FTC 1FT
1 Duplex Receptacle
1FAC 1FA
1-13/32" Opening Round
Receptacle
1FRC 1FR
1-5/8" Opening
Round Receptacle
1FGC 1FG
T H R E E G A N G
CATALOGNUMBER
DESCRIPTION
3FB
3FT
3FA
Blank
for 3
Gang Boxes
3 Toggle
Swi tches
3 Duplex
Receptac les
T W O G A N G
CATALOG NUMBERWITH WITHOUTCOATING COATING
Blank for Two Gang Boxes
2FBC 2FB
2 Toggle Switches
2FTC 2FT
2 Duplex Receptac les
2FAC 2FA
Toggle Swi tch & Duplex
Receptac le
2FTAC 2FTA
1-13/32" Openings
2 Round Receptacles
2FRC 2FR
1-5/8" Opening Round
2 Round Receptac les
2FGC 2FG
R E P L A C E M E N T G A S K E T S F O R C O V E R S( N E O P R E N E R U B B E R )
FSRG
2FSRG
3FSRG
CATALOGNUMBER DESCRIPTION
Neoprene Gaske ts
for S ingle Gang
Boxes
Neoprene Gaske ts
for 2 Gang
Boxes
Neoprene Gaske ts
for 3 Gang
Boxes
FZ/FCL-GF/FST SERIES • F ITTINGSDEVICE BOX COVERS • STANDARD AND HOSTILE LOCATIONS
F42
FEATURES-SPECIFICATIONS
Blank for
2 Gang Boxes
2 Toggle Swi tches
3 Toggle Swi tches
Blank for 3
Gang Boxes
FCL-GF Type FST TypeFZ8647
• Cast metallic covers with electrostatically applied powder coating
Lis ted F i le No. E 3397
Cer t i f i ed F i le No. LR11852
C A S T D E V I C E C O V E R S — S I N G L E G A N G( G A S K E T S I N C L U D E D )
CATALOGNUMBER
DESCRIPTION
FSBC
FZ8648
FZ8647
FST
FSPT
FSTG
Blank for S ingle
Gang Boxes
Square Toggle
Lock in ON or OFF
Posi t ion
Square Toggle
(Long Throw —
Such as Manual
S tar te rs)
1 Toggle Swi tch
For Toggle Swi tch
Toggle Swi tch
Guarded
C A S T D E V I C E C O V E R S — S I N G L E G A N G( G A S K E T S I N C L U D E D )
CATALOGNUMBER DESCRIPT ION
FCLA
FCLT
FCLR
FCLG
FCLM
FCLN
FCL-GF
FCL-VG
Duplex
Receptac le
Toggle Swi tch
Round
Receptac le
1 .406" Dia .
Round
Receptac le
1 .625" Dia .
Round
Receptac le
1 .750" Dia .
Round
Receptac le
2 .156" Dia .
Dev ice Cover
for Most
Manufac turers ’ GFI
Devices
Inc ludes Gaske ts
and Screws
Replacement
Ve l lumoid
Gaske t
C A S T D E V I C E C O V E R S — T W O A N D T H R E E G A N G ( G A S K E T S I N C L U D E D )
CATALOGNUMBER DESCRIPT ION
2FSBC
2FST
3FST
3FSBC
FSBCMI ron Blank for
Single Gang Boxes2FSBCM
I ron Blank for
2 Gang Boxes
NEW-Duplex Wall Plate for horizontalmounting on FS/FD Boxes. Castaluminum, gasketed and self-closing.Listed for wet locations with coveropen in continuous use.
FCLA2
FCL/FZ/PL SERIES • F ITTINGSDEVICE BOX ACCESSORIES • STANDARD AND HOSTILE LOCATIONS
F43
FEATURES-SPECIFICATIONS
FApplications• Use in dirty, dusty or corrosive areas
• lndoor/outdoor applications
• Where devices need physical protection
Features• May be used with several different
manufacturers’ GFI devices
• Mounts on all FS, FD, FSQ andFDQ Series boxes (single opening)
• Snap type lid. UL/CSA suitable forwet locations.
• Gaskets included
FCL
Device Covers
(For GFI Receptacles)
Applications• In wet and damp locations
• Areas where dust or dirt are a problem
• With standard toggle switches ormanual motor starters
Features• Copper-free aluminum
• Gaskets included
• Three toggle operator choices
• Lock “ON” or “OFF” provisionstandard
• Stainless steel screws
• Mounts on all FS, FD, FSQ andFDQ Series boxes (single opening)
FZ PL
Applications• Wet and damp locations
• Areas where dirt, dust or corrosion is a problem
• Washdown areas such as food processing plants or dairies
Features• Non corrosive yellow polyethylene
ring
• Molded neoprene boot on plug
Lis ted - F i le E3397
Cer t i f i ed - F i le LR11852
Lis ted - F i le E3397
Cer t i f i ed - F i le LR11852
CATALOG ITEMNUMBER
FCL-GFDevice cover inc ludes gaske tsand screws
FCL-VGReplacementVel lumoidgaske t
CATALOG NEMA CONFIGURATIONNUMBER AND RATING
Cord d iameterPL-7.375(9) / .625(16)
CATALOG TYPE OF TOGGLENUMBER SWITCH HANDLE
FZ8648 Square toggle
Square toggleFZ8647 (Long throw-such as
manual s ta r te rs)
FZ Round toggle
FCL-GF FZ-8647 PL
Not CSA approved.
VJ SERIES • F ITTINGSOUTLET BOXES • STANDARD AND HOSTILE LOCATIONS
F44
FEATURES-SPECIFICATIONS
Applications• VJ Series round boxes are available
in three depths for use as spliceboxes, for hanging pendant fixturesby using hub covers; or by using aVBA plate (see page L11), will takeVFC fixture caps
• Cover mounting centers are 3-1/2"and will accommodate 4" round oroctagonal box covers and devices.Screw holes are 8-32 size
• VJ Series are furnished with four“X” conduit openings and threeclose-up plugs
• Gaskets are required for wet anddamp locations
Features• Suitable for wet and damp locations
(when gasketed)
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
Lis ted - F i le E30107 and E3397
Cer t i f i ed - F i le LR11852
See f i les for de ta i ls or ca l l K i l la rk .
CATALOG NUMBERSHALLOW MEDIUM DEEP CONDUIT HUB
1-5/8"(00) 2-1/4"(57) 3-5/8"(92) SIZE ARRANGEMENT
VLJSX-1 VLJX-1 – 1/2" x
VLJSX-2 VLJX-2 VLJDX-2 3/4" x
– VLJX-3 VLJDX-3 1" x
B O X E S W I T H L U G S
MAXIMUM VOLUMESERIES CONDUIT SIZE CUBIC INCHES
Shal low 3/4" 17
Medium 1" 25
Deep 1-1/4" 45
B A C K C O N D U I T O P E N I N G S
Note: Must be drilled and tapped.
VJBC Blank Cover VJH-1 or VJH-2 Hub Cover VBNB Gasket
C O V E R S A N D G A S K E T S
Note: Cover and gasket not included.
CATALOG HUB SIZE DEPTHNUMBER DESCRIPTION
VJBC – 1/4" Blank cover furn ished wi th mount ing screws. Gaske t not inc luded
VJH-1 1/2" 1" Hub cover furn ished wi th mount ing screws. Gaske t not inc luded
VJH-2 3/4" 1" Hub cover furn ished wi th mount ing screws. Gaske t not inc luded
VBNB – – Gaske t Ni t r i le Butadiene
VLJSX Shallow VLJX Medium VLJDX Deep
VLJSX VLJX
VLJ Series
VLJDX
VJ Series
EY SERIES • F ITTINGSSEALING FITTINGS
F45
FEATURES-SPECIFICATIONS
FApplication & Installation
Class I, Divisions 1 and 2The purpose of seals in a Class Ihazardous location is to minimize thepassage of gases and vapors andprevent the passage of flames fromone electrical installation to anotherthrough the conduit system. Sealsare required to be installed within 18inches on any conduit run enteringan enclosure which contains devicesthat may produce arcs, sparks, orhigh temperature. Where two enclosuresare connected by a run of conduit notover 3 ft. long, a single seal locatedat the center of the run is consideredsatisfactory. Only explosionproofunions, couplings, elbows, and con-duit bodies similar to “L”, “T”, and“X” type shall be permitted betweenthe sealing fitting and the enclosure.
Seals shall be located within 18 inchesof the enclosure or fitting on eachconduit run of 2 inch size or largerentering an enclosure or fitting thatcontains terminals, splices, or taps.
Each run of conduit from a hazardouslocation to a nonhazardous locationshould be sealed to minimize theamount of gases and vapors commu-nicated beyond the seal.
Class II, Divisions 1 and 2Where a raceway provides communi-cation between an enclosure which isrequired to be dust-ignitionproof andone which is not, suitable means shallbe provided to prevent the entranceof dust into the dust-ignitionproofenclosure through the raceway.
Schematic drawings illustrate the appli-
cation of sealing compound, fiber
dams, and installed seal with drain.
Class I, Div. 1 & 2, Groups A,B,C,DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
Considerations for selection seals:Select the proper sealing fitting forthe hazardous gas/vapor involved;i.e., Class I Groups A, B, C, or D.Zone 1, Groups IIC, IIB, IIC
Select a sealing fitting for the properuse in respect to mounting position.This is particularly critical when theconduit runs between hazardous andnonhazardous areas. Some seals aredesigned to be mounted in any posi-tion; others are restricted to verticalmounting.
DrainsWhere there is a probability that liq-uid or other condensed vapor maybe trapped within enclosures forcontrol equipment or at any point inthe raceway system, approvedmeans — such as installation ofdrain seals — shall be provided toprevent moisture accumulation.
For more complete data or specialapplications, consult the code oryour local inspector.
Sealing compounds shall beapproved for the purpose and shallnot be affected by the surroundingatmosphere or liquids, and shall nothave a melting point of less than93°C. (200°F.).
In the complete seal, the minimumthickness of the sealing compoundshall not be less than the trade sizeof the conduit, and in no case lessthan 5/8 inch.
Note: The amount of Killark sealingcompound and packing fiberrequired for any seal is determinedby volume hub size and mountingposition of the seal. Refer to installa-tion data table on page F49 for specific amounts required.
Splices and taps shall not be madein fittings intended only for sealingwith compound, nor shall other fit-tings in which splices or taps aremade be filled with compound.
Killark sealing fittings are producedwith utmost care to insure a sub-stantial margin of safety. Threadsare clean, deep, and snug. Whenproperly installed with Killark sealingcompound (SC Type) and Killark non-asbestos fiber (PF Type) for thedams, you can be sure your installa-tion will provide more than adequatesafety.
EYS EYS with Nipple
(For Vertical or Horizontal Conduit)
EYD EYD with Nipple
(Drain/Seal for Vertical Conduit)
EY EY with Nipple
(For Vertical Conduit)
ENY ENY with Nipple
(For Vertical or Horizontal Conduit) ENY-2
(Fixture Hanger)
(See Page L146)
ENY/EYS SERIES • F ITTINGSSEALING FITTINGS
F46
FEATURES-SPECIFICATIONS
E N Y S E A L I N G F I T T I N G S
A BTURNINGRADIUS
HUB SIZE
E N Y W I T H N I P P L E
ENY Series EYS Series
Dimensions
ENY ENY with Nipple
(For Vertical or Horizontal Conduit)
EYS EYS with Nipple
(For Vertical or Horizontal Conduit)
DIMENSIONS
E Y S S E A L I N G F I T T I N G S
A BTURNINGRADIUS
—
—
—
—
—
—
EYS-7M
EYS-8M
EYS-9M
EYS-0M
3-15/16"(100)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
7-5/8"(194)
7-5/8"(194)
7-1/8"(181)
7-1/8"(181)
1-13/16"(46)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
4-1/2"(114)
4-1/2"(114)
5-3/16"(132)
5-3/16"(132)
1-3/16"(30)
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
4-1/8"(105)
4-3/8"(111)
4-3/4"(121)
4-3/4"(121)
—
—
—
—
—
—
EYS-7-TM
EYS-8-TM
EYS-9-TM
EYS-0-TM
HUB SIZE
CATALOG NUMBER
E Y S W I T H N I P P L E
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EYS-1
EYS-2
EYS-3
EYS-4
EYS-5
EYS-6
EYS-7
EYS-8
EYS-9
EYS-0
D IMENSIONSCATALOG NUMBER
ENY-1, 2, 3, 4, 5, 6Class I, Div. 1 & 2, Groups A,B,C,DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
EYS SeriesClass I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
Lis ted F i le No. E10514
Cer t i f i ed F i le No. LR11716
ENY-1-T
ENY-2-T
ENY-3-T
ENY-4-T
ENY-5-T
ENY-6-T
ENY-1M
ENY-2M
ENY-3M
ENY-4M
ENY-5M
ENY-6M
3-15/16"(100)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
1-13/16"(46)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
1-3/16"(30)
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
ENY-1
ENY-2
ENY-3
ENY-4
ENY-5
ENY-6
ENY-1-TM
ENY-2-TM
ENY-3-TM
ENY-4-TM
ENY-5-TM
ENY-6-TM
CATALOG NUMBER
CATALOG NUMBER
EYS-1-T
EYS-2-T
EYS-3-T
EYS-4-T
EYS-5-T
EYS-6-T
EYS-7-T
EYS-8-T
EYS-9-T
EYS-0-T
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc, chro-mate sealant, and electrostaticallyapplied powder coating
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
See f i les for de ta i ls or ca l l K i l la rk .
EY/EYD SERIES • F ITTINGSSEALING FITTING
F47
FEATURES-SPECIFICATIONS
F
EYD EYD with Nipple
(Drain/Seal for vertical conduit)
EY & EYD SeriesClass I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
Lis ted F i le No. E10514
Cer t i f i ed F i le No. LR11716
DIMENSIONS
E Y S E A L I N G F I T T I N G S
A BTURNINGRADIUS
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EY-1M
EY-2M
EY-3M
EY-4M
EY-5M
EY-6M
EY-7M
EY-8M
EY-9M
EY-0M
3-1/16"(78)
3-1/16"(78)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(230)
7"(178)
7"(178)
8-3/4"(222)
8-3/4"(222)
2-3/4"(70)
2-11/16"(68)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
2-1/4"(57)
1-15/16"(49)
2-1/4"(57)
2-7/8"(73)
3-7/16"(87)
4-1/4"(108)
4-5/8"(117)
4-5/8"(117)
5-3/8"(138)
5-3/8"(138)
EY-1-TM
EY-2-TM
EY-3-TM
EY-4-TM
EY-5-TM
EY-6-TM
EY-7-TM
EY-8-TM
EY-9-TM
EY-0-TM
HUB SIZE
E Y W I T H N I P P L E
DIMENSIONS
E Y D S E A L I N G F I T T I N G S
A BTURNINGRADIUS
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EYD-1M
EYD-2M
EYD-3M
EYD-4M
EYD-5M
EYD-6M
EYD-7M
EYD-8M
EYD-9M
EYD-0M
4-9/32"(109)
4-9/32"(109)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(130)
7"(178)
7"(178)
8-3/4"(122)
8-3/4"(122)
3-1/8"(79)
3-1/8"(79)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-7/8"(73)
3-7/16"(87)
4-1/4"(108)
4-5/8"(117)
4-5/8"(117)
5-3/8"(137)
5-3/8"(137)
EYD-1-TM
EYD-2-TM
EYD-3-TM
EYD-4-TM
EYD-5-TM
EYD-6-TM
EYD-7-TM
EYD-8-TM
EYD-9-TM
EYD-0-TM
HUB SIZE
E Y D W I T H N I P P L E
EY Series EYD Series
Dimensions
EY EY with Nipple
(For Vertical Conduit)
EYD-1-T
EYD-2-T
EYD-3-T
EYD-4-T
EYD-5-T
EYD-6-T
EYD-7-T
EYD-8-T
EYD-9-T
EYD-0-T
EYD-1
EYD-2
EYD-3
EYD-4
EYD-5
EYD-6
EYD-7
EYD-8
EYD-9
EYD-0
CATALOG NUMBERCATALOG NUMBER
CATALOG NUMBER CATALOG NUMBER
EY-1
EY-2
EY-3
EY-4
EY-5
EY-6
EY-7
EY-8
EY-9
EY-0
EY-1-T
EY-2-T
EY-3-T
EY-4-T
EY-5-T
EY-6-T
EY-7-T
EY-8-T
EY-9-T
EY-0-T
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powder coating
Duraloy Iron
• Tri-Coat Finish of electrozinc,chromate sealant, and electro-statically applied powder coating
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
KILLARKALUMINUM
DURALOYIRON
See f i les for de ta i ls or ca l l K i l la rk .
ENY40/EYD40 SERIES • F ITTINGS40% FILL SEALING FITTINGS
F48
FEATURES-SPECIFICATIONS
ENY40-1, 2, 3, 4, 5Class I, Div. 1 & 2, Groups B, C, DClass I, Zone 1, Groups IIB+H2, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ENY40-6, 7, 8, 9, 0EYD40(1 through 0) -6, 7, 8, 9, 0Class I, Div. 1 & 2, Groups C, DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass III
ApplicationTo seal Rigid Conduit or IMCRaceways with up to 40% wire fill.
Features• A 40% wire fill capacity
• Large openings with threaded clo-sures to provide easy access toconduit hubs for making dams
• Integral bushing in conduit hubsto protect conductor insulationfrom damage
• NPT threaded hubs to ensureground continuity
• Minimum turning radius
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
• Electrostatically applied powdercoating
Duraloy Iron• Tri-Coat Finish of electrozinc,
chromate sealant, and electrostati-cally applied powder coating
E N Y 4 0 4 0 % V E R T I C A L A N D / O R H O R I Z O N TA L C O N D U I T S E A L I N G F I T T I N G S
A BTURNINGRADIUS*
HUB SIZE
D IMENSIONSCATALOG NUMBER
ENY40-1M
ENY40-2M
ENY40-3M
ENY40-4M
ENY40-5M
ENY40-6M
ENY40-7M
ENY40-8M
ENY40-9M
ENY40-0M
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
ENY40-1
ENY40-2
ENY40-3
ENY40-4
ENY40-5
ENY40-6
ENY40-7
ENY40-8
ENY40-9
ENY40-0
0.06
0.12
0.26
1.00
2.00
3.00
3.56
6.00
7.00
9.60
2
4
7
13
22
36
61
89
114
202
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
4-1/8"(105)
4-3/8"(111)
4-3/4"(121)
4-3/4"(121)
4-1/4"(108)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
4-1/2"(114)
4-1/2"(114)
5-3/16"(132)
5-3/16"(132)
6-1/2"(165)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
7-5/8"(194)
7-5/8"(194)
7-1/8"(181)
7-1/8"(181)
11-1/16"(281)
KILLARKALUMINUM
DURALOYIRON
REQUIRED SEALINGCOMPOUND &PACKING FIBER OZ.
PER HUB(PF)
E Y D 4 0 4 0 % V E R T I C A L C O N D U I T D R A I N S E A L I N G F I T T I N G S
A BTURNINGRADIUS*
HUB SIZE
D IMENSIONSCATALOG NUMBER
EYD40-1M
EYD40-2M
EYD40-3M
EYD40-4M
EYD40-5M
EYD40-6M
EYD40-7M
EYD40-8M
EYD40-9M
EYD40-0M
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EYD40-1
EYD40-2
EYD40-3
EYD40-4
EYD40-5
EYD40-6
EYD40-7
EYD40-8
EYD40-9
EYD40-0
0.03
0.06
0.13
0.50
1.00
1.50
1.75
3.00
3.50
4.50
4
6
7
13
22
36
61
89
114
202
2-1/4”(57)
2-1/4”(57)
2-7/8”(73)
3-7/16”(87)
4-1/4”(108)
4-5/8”(117)
4-5/8”(117)
5-3/8”(137)
5-3/8”(137)
4-1/4”(108)
3-1/8"(79)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
6-1/2"(165)
4-9/32"(109)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(130)
7"(178)
7"(178)
8-3/4"(122)
8-3/4"(122)
11-1/16"(281)
KILLARKALUMINUM
DURALOYIRON
REQUIRED SEALINGCOMPOUND &PACKING FIBER OZ.
PER HUB(PF)
ENY
ENY40
EYD
A
B
Turning Radius
EYD40
A
B
Turning Radius
* Turning radius with cover plug removed.
ENY/EYS/EY/EYD SERIES • F ITTINGSSEALING MATERIALS
F49
FEATURES-SPECIFICATIONS
FSEALING COMPOUND
S E A L I N G C O M P O U N D
T H R E A D L U B R I C A N T S
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
Sealing CompoundSC Series Sealing compound is acement used extensively for sealingconduit to prevent the spread ofexplosive gases. It is non-shrinkingand a secure seal is formed. SCSeries resists acids, water, oil, etc. Itis UL Listed for use with Killark ENY,EY, and EYS Series. Also CSA certi-fied for use with any CSA certifiedsealing fitting.
Packing FiberKillark’s Packing Fiber is made froman environmentally safe, non-asbestos material. It is easy to useand forms a positive dam to holdcompound (Killark SC Type) in ENY,EY, and EYS Series fittings.
Thread LubricantsTwo special blends of lubricantshave been developed by Killark foruse with threaded joints. These lubricants are to be used to preventgalling of pipe threads when threadedinto a coupling, junction box, etc.They insure a quick release ofundamaged male and female threadswhen parts are disassembled.
LUBG is a general purpose lubricantto be used in temperatures rangingfrom 0° to 125°F.
LUBT is a high-quality lubricant to beused in temperatures ranging from -40° to +500°F. It is recommended tobe used on hazardous location light-ing fixtures.
O U N C E S R E Q U I R E D P E R F I T T I N G
ENY1HUB SIZE EYS1 EY/EYDPACKING FIBER
1.5 oz .
2 .0 oz .
3 .0 oz .
6 .5 oz .
8 .5 oz .
15.0 oz .
—
—
—
—
3.0 oz .
3 .0 oz .
8 .0 oz .
8 .5 oz .
17.5 oz .
27.0 oz .
42.0 oz .
47.0 oz .
56 .0 oz .
56.0 oz .
1 .0 oz .
2 .0 oz .
4 .5 oz .
7 .5 oz .
12 .0 oz .
24.0 oz .
44.0 oz .
44.0 oz .
75.0 oz .
75.0 oz .
1/16 oz .
1/8 oz .
1/4 oz .
1/2 oz .
1 oz .
2 oz .
3 oz .
4 oz .
6 oz .
9 oz .
SIZE PACKAGECATALOG NUMBER
4 oz .
8 oz .
1 lb .
5 lbs .
SC-4 OZ
SC-8 OZ
SC-1 LB
SC-5 LB
PA C K I N G F I B E R
SIZE PACKAGECATALOG NUMBER
2 oz .
4 oz .
1 lb .
PF-2
PF-4
PF-16
CONTAINER PACKAGECATALOG NUMBER2 oz .
6 oz .
LUBT-2
LUBG-6
1/2"
3/4"
1"
1-1/4"
1 1/2"
2"
2-1/2"
3"
3-1/2"
4"
1 ENY/EYS suitable for both horizontal or vertical applications.
GEB • F ITTINGSALUMINUM OUTLET BODIES
F50
FEATURES-SPECIFICATIONS
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
ATEX Pending
Class I, Div. 1 & 2, Groups B, C, D*Class I, Zone I, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 4X
ApplicationsGEB series conduit boxes areinstalled in conduit systems withinhazardous areas to:
• Protect conductors in threadedrigid conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors formaintenance and future systemchanges
Features• Suitable for NEMA 4X applications
• Integral mounting lugs
• Green ground screw standard
• External cover thread on body plussmooth integral hub bushing pro-tects conductor insulation whenpulling
• 4 different hub arrangements
• Taper threaded hubs provideground continuity
• External threaded body for addi-tional wiring room
• Covers and gaskets furnished withboxes as standard
Material/Finish
Aluminum• BODY & COVER Copper-free
aluminum (less than 4/10 of 1%)
• FINISH Electrostatically appliedpowder coating
Size Ranges
• Hub — 3/4" to 1-1/2"
• Cover opening — 3-1/2
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
* 1-1/2" hub sizes require seal within24" for Group B applicatons.
C T Y P E O U T L E T B O D Y
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
A B C D E FCOVER
OPENING
DIMENSIONSCATALOGNUMBER
HUB SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBC-2
GEBC-3
GEBC-4
GEBC-5
29
29
29
29
VOLUMECU. IN.
L T Y P E O U T L E T B O D Y
5-1/2"(140)
5-1/2"(140)
5-1/2"(140)
5-1/2"(140)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
A B C D E FCOVER
OPENING
DIMENSIONSCATALOGNUMBER
HUB SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBL-2
GEBL-3
GEBL-4
GEBL-5
29
29
29
29
VOLUMECU. IN.
C Type L Type
C Type L Type
GEB SERIES • F ITTINGSALUMINUM OUTLET BODIES
F51
FEATURES-SPECIFICATIONS
F
Dimensions
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
ATEX Pending
Class I, Div. 1 & 2, Groups B, C, D*Class I, Zone I, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E, F, GClass IIINEMA 4X
T Type X Type
T T Y P E O U T L E T B O D Y
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6 -1/2”
(165)
6 -1/2”
(165)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
4 -5/16”
(110)
4 -5/16”
(110)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
3 -1/4”
(83)
3 -1/4”
(83)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
2 -15/16”
(75)
2 -15/16”
(75)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1 - 3/32”
(28)
1 - 3/32”
(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
1 - 3/16”
(30)
1 - 3/16”
(30)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
3 -1/2”
(89)
3 -1/2”
(89)
A B C D E FCOVER
OPENING
DIMENSIONSCATALOGNUMBER
HUB SIZE
3/4"
1"
1-1/4"
1-1/2"
(2) 3/4”
(1) 1-1/4”
(2) 3/4”
(1) 1-1/2”
GEBT-2
GEBT-3
GEBT-4
GEBT-5
GEBT-24
GEBT-25
29
29
29
29
29
29
VOLUMECU. IN.
X T Y P E O U T L E T B O D Y
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
4-5/16"(110)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
3-1/4"(83)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
2-15/16"(75)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/32"(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
3-1/2"(89)
A B C D E FCOVER
OPENING
DIMENSIONSCATALOGNUMBER
HUB SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBX-2
GEBX-3
GEBX-4
GEBX-5
29
29
29
29
VOLUMECU. IN.
T Type X Type
* 1-1/2” hub size requires seal within 24” for group B applications.
See page F50 for Standard Materials & Finish
Outlet Box for in-line (multiple) stanchion mount fixtures
Typical Applications:Coal Conveyors, Cat Walks, Platform Hand Rails
GEBT-25 with two 3/4” feed-thru hubsand one 1-1/2” vertical hub
4-3/16
”21/64”
GE SERIES • F ITTINGSALUMINUM AND IRON OUTLET BODIES
F52
FEATURES-SPECIFICATIONS
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
COVEROPENINGS
E T Y P E O U T L E T B O D Y *
3-11/16"(94)
3-11/16"(94)
3-11/16"(94)
—
6-1/4"(159)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
—
4-3/8"(111)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
—
4-7/8"(124)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
—
3-9/16"(90)
1"(25)
1"(25)
1"(25)
—
1-3/16"(46)
13/16"(21)
13/16"(21)
1-1/8"(21)
—
1-3/16"(46)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
—
4-7/8"(124)
18
18
19
—
75
GECET-1M
GECET-2M
GECET-3M
—
GEJET-5M
GECET-1
GECET-2
GECET-3
—
GEJET-5
1/2"
3/4"
1"
1-1/4"
1-1/2"
A B C D E F
DIMENSIONS
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
ApplicationsGE series conduit boxes areinstalled in conduit systems withinhazardous areas to:
• Protect conductors in threadedrigid conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors formaintenance and future systemchanges
FeaturesGE conduit outlet boxes have:
• GEM, GEC and GES have watershedding cover — suitable for wetlocations when mounted in uprightposition
• External cover threads on bodyprotecting conductors from dam-age during pulling
• No pinching of conductors duringcover installation
• Ten different hub arrangements
• Taper threaded hubs to provideground continuity
• Smooth integral hub bushing to protect conductor insulation whenpulling
• Internally threaded cover openingsfor additional wiring room
• Covers furnished with boxes
• Weather-resistant finish
• Green ground screw standard inall boxes
• 1/2", 3/4" and 1" Bodies Class I, Div. 1 & 2, Groups C & DClass I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" BodiesClass I,Div. 1 & 2, Group DClass I, Zone 1, Group IIA
• All Bodies Class II and Class III
• For GEJ Series CSA applications for Class I Group C, seal conduit within 18 inches
E Type
Dimensions
KILLARKALUM.
DURALOYIRON
Material/Finish
Aluminum• BODY Copper-free aluminum
(less than 4/10 of 1%)
• FINISH Electrostatically appliedpowder coating
• COVER (Aluminum) Copper-free aluminum (less than4/10 of 1%). Electrostatically applied powder coating
Iron
• BODY Duraloy iron alloy
• FINISH Tri-coat finish of electroz-inc, chromate sealant, and electro-statically applied powder coating
• COVER (Aluminum) Copper-free aluminum (less than4/10 of 1%). Electrostatically applied powder coating
Size Ranges• Hub — 1/2" to 2"
• Cover opening — 2-1/16" to 4-7/8" diameter
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
GEJET Type
* For GROUP B applications, contact factory.
GE SERIES • F ITTINGSALUMINUM AND IRON OUTLET BODIES
F53
FEATURES-SPECIFICATIONS
F
Dimensions
VOLUMECU. IN.
COVEROPENINGS
C T Y P E O U T L E T B O D Y *
2-13/16"(71)
2-13/16"(71)
3-11/16"(94)
3-11/16"(94)
3-11/16"(94)
5-1/16"(128)
5-1/16"(128)
6-1/4"(159)
6-1/4"(159)
3"(76)
3"(76)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
4-1/8"(105)
4-3/8"(111)
4-3/8"(111)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
2-5/16"(79)
2-5/16"(79)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
3-7/16"(87)
3-9/16"(90)
3-9/16"(90)
11/16"(17)
11/16"(17)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
1-1/16"(27)
1-3/16"(30)
1-1/2"(38)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
1-1/8"(28)
1-1/8"(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
8
8
19
19
19
42
42
75
75
—
—
GECCT-1M
GECCT-2M
GECCT-3M
GESCT-3M
GESCT-4M
GEJCT-5M
GEJCT-6M
GEMC-1
GEMC-2
GECCT-1
GECCT-2
GECCT-3
GESCT-3
GESCT-4
GEJCT-5
GEJCT-6
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
A B C D E F
DIMENSIONS
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
• 1/2", 3/4" and 1" Bodies Class I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies Class I, Div. 1 & 2, Group DClass I, Zone 1, Group IIA
• All Bodies Class II and Class III
• For GEJ Series CSA applications for Class I Group C, seal conduit within 18 inches
GES
C Type
GEM
L Type
See page F52 for Standard Materials & Finish
C Type
L Type
Applicable Third Party StandardsUL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
L T Y P E O U T L E T B O D Y *
2-13/16"(71)
2-13/16"(71)
3-11/16"(94)
3-11/16"(94)
3-11/16"(94)
5-1/16"(128)
5-1/16"(128)
6-1/4"(159)
6-1/4"(159)
3"(76)
3"(76)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
4-1/8"(105)
4-3/8"(111)
4-3/8"(111)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
2-5/16"(79)
2-5/16"(79)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
3-7/16"(87)
3-9/16"(87)
3-9/16"(87)
11/16"(17)
11/16"(17)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
1-1/16"(27)
1-3/16"(30)
1-1/2"(38)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(28)
1-1/8"(28)
1-3/16"(30)
1-3/16"(30)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
8
8
19
19
19
42
42
75
75
—
—
GECLT-1M
GECLT-2M
GECLT-3M
GESLT-3M
GESLT-4M
GEJLT-5M
GEJLT-6M
GEML-1
GEML-2
GECLT-1
GECLT-2
GECLT-3
GESLT-3
GESLT-4
GEJLT-5
GEJLT-6
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
CATALOG NUMBERHUB SIZEKILLARK
ALUM.DURALOYIRON
* For GROUP B applications, contact factory.
GE SERIES • F ITTINGSALUMINUM AND IRON OUTLET BODIES
F54
FEATURES-SPECIFICATIONS
See page F52 for Standard Materials & Finish
Applicable Third Party StandardsUL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
T Type
X Type
LB Type
GES
X Type
GEJ
LB Type
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
COVEROPENINGS
T T Y P E O U T L E T B O D Y *
2-13/16"(56)
2-13/16"(56)
3-11/16"(93)
3-11/16"(93)
3-11/16"(93)
5-1/16"(129)
5-1/16"(129)
6-1/4"(159)
6-1/4"(159)
3"(76)
3"(76)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
4-1/8"(105)
4-3/8"(111)
4-3/8"(111)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
2-5/16(59)
2-5/16(59)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
3-7/16"(87)
3-9/16"(90)
3-9/16"(90)
11/16"(17)
11/16"(17)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
1-1/16"(27)
1-3/16"(30)
1-1/2"(38)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
1-1/8"(29)
1-1/8"(29)
1-3/16"(30)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
8
8
19
19
19
42
42
75
75
—
—
GECTT-1M
GECTT-2M
GECTT-3M
GESTT-3M
GESTT-4M
GEJTT-5M
GEJTT-6M
GEMT-1
GEMT-2
GECTT-1
GECTT-2
GECTT-3
GESTT-3
GESTT-4
GEJTT-5
GEJTT-6
A B C D E F
DIMENSIONS
X T Y P E O U T L E T B O D Y *
2-13/16"(56)
2-13/16"(56)
3-11/16"(93)
3-11/16"(93)
3-11/16"(93)
5-1/16"(129)
5-1/16"(129)
6-1/4"(159)
6-1/4"(159)
3"(76)
3"(76)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
4-1/8"(105)
4-3/8"(111)
4-3/8"(111)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
2-5/16(59)
2-5/16(59)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
3-7/16"(87)
3-9/16"(90)
3-9/16"(90)
11/16"(17)
11/16"(17)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
1-1/16"(27)
1-1/2"(38)
1-1/2"(38)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
1-1/8"(29)
1-1/8"(29)
1-3/16"(30)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
8
8
19
19
19
42
42
75
75
—
—
GECXT-1M
GECXT-2M
GECXT-3M
GESXT-3M
GESXT-4M
GEJXT-5M
GEJXT-6M
GEMX-1
GEMX-2
GECXT-1
GECXT-2
GECXT-3
GESXT-3
GESXT-4
GEJXT-5
GEJXT-6
L B T Y P E O U T L E T B O D Y *
2-13/16"(56)
2-13/16"(56)
3-11/16"(93)
3-11/16"(93)
3-11/16"(93)
5-1/16"(129)
5-1/16"(129)
6-1/4"(159)
6-1/4"(159)
3"(76)
3"(76)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
4-1/8"(105)
4-3/8"(111)
4-3/8"(111)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
2-5/16(59)
2-5/16(59)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
3-7/16"(87)
3-9/16"(90)
3-9/16"(90)
11/16"(17)
11/16"(17)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
1-1/16"(27)
1-1/2"(38)
1-1/2"(38)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
1-1/8"(29)
1-1/8"(29)
1-3/16"(30)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
3-9/16"(90)
4-7/8"(124)
4-7/8"(124)
8
8
19
19
19
42
42
75
75
—
—
GECLBT-1M
GECLBT-2M
GECLBT-3M
GESLBT-3M
GESLBT-4M
GEJLBT-5M
GEJLBT-6M
GEMLB-1
GEMLB-2
GECLBT-1
GECLBT-2
GECLBT-3
GESLBT-3
GESLBT-4
GEJLBT-5
GEJLBT-6
Dimensions
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
• 1/2", 3/4" and 1" Bodies Class I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies Class I, Div. 1 & 2, Group DClass I, Zone 1, Group IIA
• All Bodies Class II and Class III
• For GEJ Series CSA applications for Class I Group C, seal conduit within 18 inches
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
KILLARKALUM.
DURALOYIRON
GEC
T Type
* For GROUP B applications, contact factory.
GE SERIES • F ITTINGSALUMINUM AND IRON OUTLET BODIES
F55
FEATURES-SPECIFICATIONS
F
GEM
TA Type
See page F52 for Standard Materials & Finish
Applicable Third Party StandardsUL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Dimensions
TAT Type XAT Type
CAT Type EAT Type
TAT T Y P E O U T L E T B O D Y *
2-13/16"(56)
3"(76)
2-1/16"(52)
2-5/16"(59)
11/16"(17)
13/16"(21)
2-1/16"(52)
8
GECTAT-2M
GEMTA-1
GEMTA-2
GECTAT-2
1/2"
3/4"
3/4"
C AT T Y P E O U T L E T B O D Y *
2-13/16"(56)
2-13/16"(56)
3"(76)
3"(76)
2-1/16"(52)
2-1/16"(52)
2-5/16"(59)
2-5/16"(59)
11/16"(17)
11/16"(17)
13/16"(21)
1-3/16"(30)
2-1/16"(52)
2-1/16"(52)
8
8
—
—
GEMCA-1
GEMCA-2
1/2"
3/4"
1/2"
1-1/4"5-11/16
(144)4-1/8"(105)
3-9/16"(90)
3-7/16"(87)
1-1/16"(27)
1-3/16"(30)
3-9/16"(90)
42GESCAT-4MGESCAT-4
3-11/16(94)
3-5/8"(92)
2-11/16"(68)
2-3/4"(70)
1"(25)
13/16"(21)
2-11/16"(68)
19GECCAT-1MGECCAT-1
E AT T Y P E O U T L E T B O D Y *
3-11/16"(94)
3-5/8"(92)
2-11/16"(68)
2-3/4"(70)
1"(25)
13/16"(21)
2-11/16"(68)
19GECEAT-2MGECEAT-2 3/4"
X AT T Y P E O U T L E T B O D Y *
3-11/16"(94)
3-11/16"(94)
3-11/16"(94)
5-1/16"(128)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
4-1/8"(105)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3-7/16"(87)
1"(25)
1"(25)
1"(25)
1-1/16"(27)
13/16"(21)
13/16"(21)
13/16"(21)
1-3/16"(30)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
3-9/16"(90)
19
19
19
42
GECXAT-1M
GECXAT-2M
GECXAT-3M
GESXAT-4M
GECXAT-1
GECXAT-2
GECXAT-3
GESXAT-4
1/2"
3/4"
1"
1-1/4"
L is ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
• 1/2", 3/4" and 1" Bodies Class I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies — Class I, Div. 1 & 2, Group DClass I, Zone 1, Group IIA
• All Bodies — Class II and Class III
• For GEJ Series CSA applications for Class I Group C, seal conduit within 18 inches
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
COVEROPENINGS
L A T Y P E O U T L E T B O D Y *
2-13/16"(56)
3"(76)
2-1/16"(52)
2-5/16"(59)
11/16"(17)
13/16"(21)
2-1/16"(52)
8—GEMLA-1 1/2"
2-13/16"(56)
3"(76)
2-1/16"(52)
2-5/16"(59)
11/16"(17)
13/16"(21)
2-1/16"(52)
8—GEMLA-2 3/4"
A B C D E F
DIMENSIONS
2-13/16"(56)
3"(76)
2-1/16"(52)
2-5/16"(59)
11/16"(17)
13/16"(21)
2-1/16"(52)
8
3-11/16"(94)
3-5/8"(92)
2-11/16"(68)
2-3/4"(70)
1"(25)
13/16"(21)
2-11/16"(68)
19
—
—
KILLARKALUM.
DURALOYIRON
GEM
CA Type
GESXAT
XA Type
GEM
LA Type
GEC
EAT Type
* For GROUP B applications, contact factory.
GEC SERIES • F ITTINGSOUTLET BODIES WITH MOUNTING FLANGE
F56
FEATURES-SPECIFICATIONS
See page F52 for Standard Materials & Features
Applicable Third Party StandardsUL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
•1/2", 3/4" and 1" Bodies Class I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIA
Material/Finish
Aluminum• BODY Copper-free aluminum
(less than 4/10 of 1%)
• FINISH Electrostatically appliedpowder coating
• COVER (Aluminum) Copper-free aluminum (less than4/10 of 1%). Electrostatically applied powder coating
Iron
• BODY Duraloy iron alloy
• FINISH Tri-Coat Finish ofElectrozinc, Chromate Sealant, and electrostatically appliedpowder coating
• COVER (Aluminum) Copper-free aluminum (less than4/10 of 1%). Electrostatically applied powder coating
Size Ranges:• Hub — 3/4" standard
optional 1/2” to 1”
contact factory
• Cover opening — 2-11/16" or 2-1/16”
GECXTF
XTF Type Outlet Body
With Mounting Flange
XTF Type
With Mounting Flange
HUB SIZE
CATALOG NUMBERVOLUMECU. IN.
COVEROPENINGS
X T F T Y P E O U T L E T B O D Y *
3-11/16"(94)
3-11/16"(94)
3-11/16"(94)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
1"(25)
1"(25)
1"(25)
13/16"(21)
13/16"(21)
13/16"(21)
2-11/16"(68)
2-11/16"(68)
2-11/16"(68)
19
19
19
GECXTF-1M
GECXTF-2M
GECXTF-3M
GECXTF-1
GECXTF-2
GECXTF-3
1/2"
3/4"
1"
A B C D E F
DIMENSIONSKILLARKALUM.
DURALOYIRON
GECUET-2
Outlet Body
GEUEAT-2
Outlet Body
GECUWT-2
Outlet Body
GECUET-2
Outlet Body
GEUEAT-2
Outlet Body
GECUWT-2
Outlet Body
G E T Y P E O U T L E T B O D Y *
3-11/16"(94)
2-13/16"(56)
3-11/16"(94)
3-5/8"(92)
3"(76)
3-5/8"(92)
2-11/16"(68)
2-1/16"(52)
2-11/16"(68)
2-3/4"(70)
2-1/8"(54)
2-3/4"(70)
1"(25)
1"(25)
1"(25)
13/16"(21)
13/16"(21)
13/16"(21)
2-11/16"(68)
2-1/16"(52)
2-11/16"(68)
19
11
19
GECUET-2M
GECEAT-2M
GECUWT-2M
GECUET-2
GECEAT-2
GECUWT-2
3/4"
3/4"
3/4"
* For GROUP B applications, contact factory.
GE SERIES • F ITTINGSOUTLET BODIES ACCESSORIES
F57
FEATURES-SPECIFICATIONS
F
S E A L I N G C O V E R
• Sealing cover used to convertbody into sealing fitting
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically applied powder coating
• Blank covers are supplied standardon all GE Series bodies
• Dome covers provide additionalwiring room for splicing or accom-modating components
• Rubber gasket fits between coverand body to make assembly watertight
• Complies with NEMA 4
• Clear cover lens for viewing
CATALOG NUMBER SERIES
B L A N K C O V E R
GEMBC
GECBC*
GESBC
GRM-BC
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
D O M E C O V E R
2GOU
4GOU
3GRMD
5GRMD
GEC
GEC
GEJ
GEJ
VOLUME CUB IC INCH
13.3
47.0
55.0
80.0
CATALOG NUMBER SERIES
G A S K E T
GEM-RG
GEC-RG
GES-RG
GRM-RG
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
GEMEY1
GECEY
GESEY
GEJEY
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
L E N S C O V E R
GL-375 GEJ
Blank Cover 4GOU
Dome Cover
GasketLens Cover Sealing Cover
1Sealing Covers CSA only.
Since all Series GE boxes are listed with a blank cover, deduct the price of blank cover and add the
price of the desired cover. Outlet bodies listed on preceding page.
* Available also in iron GECBCM
GR SERIES • F ITTINGSOUTLET BODIES
F58
FEATURES-SPECIFICATIONS
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
GRR
Features
• Cast conduit hubs with integralbushings
• Blank cover included
• Replacement cover catalog number GRRBC
• Compact size
• Supplied with five hubs and threeclose-up plugs
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Class I, Div. 1 & 2, Groups C,DClass II, Div. 1 & 2, Groups E,F,GClass III
CATALOG NUMBER HUB SIZE
GRR-1 1/2"
GRR-2 3/4"
GRR-3 1"
Blank Cover-only-GRRBC
G R R W / B L A N K C O V E R
GRSA
Features
• Cast conduit hubs with integralbushings
• Cover included
• Replacement cover catalog number GECBC
• Five close-up plugs included
• Sealing, hub, dome covers and gaskets available (page F57)
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
GRSA GRR
Dimensions
GRR 1 & 2 GRR-3
CATALOG NUMBER HUBS
Furnished wi th e ight 3/4" GRSA hubs inc luding one 3/4" f lush
hub in back center
G R S A W / B L A N K C O V E R
VOLUMECU. IN.
26.5
VOLUMECU. IN.
13.0
13.0
14.0
CATALOG NUMBER
GEC-RG
G A S K E T ( R U B B E R )
CATALOG NUMBER
GRCEX-0
* Adds 2-7/8" to bodydepth and16.48 cu. in.
E X T E N S I O N *
GR SERIES • F ITTINGSOUTLET BODIES
F59
FEATURES-SPECIFICATIONS
F
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
Class I, Div. 1 & 2, Groups C,DClass II, Div. 1 & 2, Groups E,F,GClass III
GRSSA DimensionsGRSS Dimensions
GRSSAGRSS
CLOSE-UPPLUGSFURNISHED
VOLUMECU. IN.
COVEROPENINGS
G R S S / G R S S A D I M E N S I O N S
GRSS-1GRSS-2GRSS-3GRSSA-1GRSSA-2
1/2"
3/4"
1"
1/2"
3/4"
7
7
7
13
13
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
2-3/8"
2-3/8"
2-3/8"
2-3/8"
2-3/8"
2-1/8"
2-1/8"
2-1/8"
2-1/8"
2-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
29
29
29
20
20
1-3/16"
1-3/16"
1-3/16"
1-3/16"
1-3/16"
4-5/8"
4-5/8"
4-5/8"
4-5/8"
4-5/8"
N/A
N/A
N/A
2-1/8"
2-1/8"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
4
4
4
5
5
A B C D E F G H
DIMENSIONS IN INCHESCATALOGNUMBER
NO. OFOPENINGS
HUB SIZE
GRSS/GRSSA
Features • Internal hubs
• Blank cover included (Cat. No. GRRBC)
• Compact design and multiple hubconfigurations
• Furnished with internal ground screw
• Cast-in brackets on cover for use withbreaker-bar tools
GRSS TypeFurnished with seven internal hubs, twohubs are on the top and bottom, oneeach on the two sides and one hub inthe back. Four close-up plugs supplied.Series GUM unions can be used.
GRSSA TypeFurnished with 13 hubs, two on eachside and five in back. Five close-upplugs are supplied.
Material/Finish - Aluminum Body• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Material/Finish - Duraloy Iron Body• Duraloy iron alloy
• Tri-Coat finish of Electrozinc,Chromate Sealant and electrostatical-ly applied powder coating
Material/Finish - GR Series Cover• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
NUMBER OFNUMBER CLOSE-UP
KILLARK DURALOY HUB OF PLUGSALUM. IRON SIZE OPENINGS FURNISHED
GRSS-1 GRSS-1M 1/2 " 7 4
GRSS-2 GRSS-2M 3/4 " 7 4
GRSS-3 – 1" 7 4
GRSSA-1 – 1/2 " 13 5
GRSSA-2 – 3/4 " 13 5
G R S S / G R S S A
CATALOG NUMBER
CATALOG NUMBER
GEC-RG
G A S K E T ( R U B B E R )
CATALOG NUMBER
GRCEX-0
* Adds 2-7/8" to bodydepth.
E X T E N S I O N *
X/XALB SERIES • F ITTINGSCONDUIT BODIES
F60
FEATURES-SPECIFICATIONS
X
Features
• Integral bushings
• Easy access covers
• Six hub styles
• Sizes 1/2", 3/4", 1"
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
X SeriesClass I, Div. 1 & 2, Groups C,D1
Class II, Div. 1 & 2, Groups E,F,GClass III
X D I M E N S I O N S
1X Series 1" hub size suitable for
Class I, Group D
XALB
Applications
Designed to permit straight pulls ofheavy cable.
Features • Integral bushings
• Easy access covers
• Sizes 1-1/4" thru 3"CATALOG NUMBER HUB SIZE
XALB-4 1-1/4"
XALB-5 1-1/2"
XALB-6 2"
XALB-7 2-1/2"
XALB-8 3"
XALB Series suitable for Class 1, Group D only.
X A L B C O N D U I T B O D I E S
XALB SeriesClass I, Div. 1 & 2, Group DClass II, Div. 1 & 2, Groups E,F,GClass III
A BCONDUIT OVERALL LENGTH WIDTHSIZE DEPTH OF BODY OF BODY
1-1/4" 4-1/16"(103) 7-3/4"(197) 3-15/16"(100)
1-1/2" 4-1/16"(103) 7-3/4"(197) 3-15/16"(100)
2" 5-7/8"(149) 11-1/8"(282) 4-3/4"(121)
2-1/2" 8-1/4"(209) 17-1/2"(444) 6-7/16"(163)
3" 8-1/4"(209) 17-1/2"(444) 6-7/16"(163)
X A L B D I M E N S I O N S
XT-2
XLR-2
XALBXLRT-21
XLL-2
ALENGTH
5-9/16"
5-13/16"
6-1/16"
4-5/8"
4-29/32"
5-9/16"
4-5/8"
4-29/32"
5-17/32
4-5/8"
4-29/32"
5-9/16"
5-9/16"
5-13/16"
6-11/16"
5-3/4"
5-3/4"
BWIDTH
1-17/32"
1-3/4"
2-3/8"
2-7/16"
2-5/8"
3-1/2"
1-17/32"
1-3/4"
2-3/8"
2-7/16"
2-5/8"
3-1/2"
2-7/16"
2-5/8"
3-1/2"
2-21/32"
2-21/32"
CHEIGHT
2-1/8"
2-1/4"
2-1/2"
2-1/8"
2-1/4"
2-1/2"
2-15/16"
3-1/8"
3-5/8"
2-1/8"
2-1/4"
2-1/2"
2-1/8"
2-1/4"
2-1/2"
2-1/2"
2-1/2"
D
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
11/16"
11/16"
E
—
—
—
3/4"
7/8"
7/8"
3/4"
11/16"
7/8"
3/4"
7/8"
7/8"
—
—
—
—
—
VOLUMECU. IN.
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
7
7
CATALOG HUBNUMBER SIZE
XC-1 1/2"
XC-2 3/4"
XC-3 1"1
XLL-1 1/2"
XLL-2 3/4"
XLL-3 1"1
XLB-1 1/2"
XLB-2 3/4"
XLB-3 1"1
XLR-1 1/2"
XLR-2 3/4"
XLR-3 1"1
XT-1 1/2"
XT-2 3/4"
XT-3 1"1
XLRT-213/4" Ends
1/2" S ide
XLRT-223/4" End
3/4" S ide
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Electrostatically appliedpowder coating
A C
BD
A C
BD
A C
B
A C
B
D
D
E
A C
B
D
A C
BD
E
1X Series 1" hub size suitable for Class 1, Group D
J A L O U T L E T B O D I E S W I T H C O V E R
J L O U T L E T B O D I E S W I T H C O V E R
JL/JAL SERIES • F ITTINGSOUTLET BODIES
F61
FEATURES-SPECIFICATIONS
F
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
Class I, Div. 1 & 2, Groups C,D Class II, Div. 1 & 2, Groups E,F,GClass III
R E P L A C E M E N T B L A N K C O V E R
ApplicationsTo provide access to conductors forpulling, splicing, and maintenance.May be used as a fixture hanger.
Features• Option of blank or hub covers
• Cast mounting lugs
• Large wiring area
• Furnished with internal groundscrew
• Hub covers include set screws forlocking to lighting fixture stems
• JL - Cast external hubs with integralbushings
• JAL - Four drilled and tapped con-duit openings in an “x” configuration(three, close-up plugs included toallow five variations from one body)
• Option of blank or hub covers
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural Finish
1To order box only omit last digit of catalog number.
CATALOG NUMBERWITH BLANK WITH HUBCOVER COVER
JLC-10 JLC-11
— JLC-12
JLC-20 JLC-21
— JLC-22
JLX-10 JLX-11
— JLX-12
JLX-20 JLX-21
— JLX-22
CONDUIT SIZE
BOX1 COVER
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
BOXTYPE
1To order box only omit last digit of catalog number. 21-1/4" for Class I, Group D.
CATALOG NUMBERWITH BLANK WITH HUBCOVER COVER
JALX-10 JALX-11
— JALX-12
JALX-20 JALX-21
— JALX-22
JALX-30 JALX-31
— JALX-32
JALX-40 —
CONDUIT SIZE
BOX1 COVER
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
1" 1/2"
1" 3/4"
1-1/4"2 1/2"
TYPE
C
C
C
C
X
X
X
X
X
X
X
X
X
X
X
JLC-20 JLX-21
JL 1-2 JAL 1-3 JAL 4
JCB
JAH-2JALX-22JALX-20
D I M E N S I O N S
SERIES A B C D E F GJL 1/2", 3/4" 1-15/16" 11/16" 3-1/4" 4-7/32" 2-3/8" 5-1/8"
JAL 1/2", 3/4", 1" 2-3/8" 1-5/32" 4-3/4" 5-1/4" 4-1/8" 5-7/8"
JAL 1-1/4" 3-3/16" 1-17/32" 4-5/8" 5-1/4" 4-1/8" 5-7/8"
BOX ONLY VOL. CU. IN.
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
BOX ONLY VOL. CU. IN.
26.5
26.5
26.5
26.5
26.5
26.5
39
CATALOGNUMBER
JCB
JABC
SERIES
JL
JAL
SERIES
JL
JL
JAL
JAL
DEPTH
5/8"
1-1/8"
VOLUMECU. IN.
1.0
7.5
R E P L A C E M E N T H U B C O V E R
CATALOGNUMBER
JH-1
JH-2
JAH-1
JAH-2
HUBSIZE
1/2"
3/4"
1/2"
3/4"
DEPTH
1-3/32"
1-3/32"
1-1/8"
1-1/8"
VOLUMECU. IN.
1.5
1.5
6.5
6.5
G3-1/4"
4-3/4"
4-13/16"
GU/UN SERIES • F ITTINGSUNIONS
F62
FEATURES-SPECIFICATIONS
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716Female to Female Male to Female 90° Elbow Union
DIMENSIONS
1UL & CSA suitable for Class I, Groups A, B, C, D.
•GUF/GUM/UNF/UNY 1/2", 3/4", & 1"Class I, Div. 1 & 2, Groups A,B,C,DClass I, Zone I, IIC, IIB, IIAClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
•GUF/GUM/UNF/UNY 1-1/4" through 4"Class I, Div. 1 & 2, Groups C,DClass I, Zone I, IIB, IIAClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
GUMLUNY UNF
HUB S IZECATALOG NUMBER
F E M A L E T O F E M A L E
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/2"
3/4"
1"
1-1/4"
1/2"
2"
2-1/2"
3"
3-1/2"
4"
UNF11
UNF21
UNF31
UNF4
UNF5
UNF6
UNF7
UNF8
UNF9
UNF0
GUF-11
GUF-21
GUF-31
GUF-4
GUF-5
GUF-6
GUF-7
GUF-8
GUF-9
GUF-0
2-3/16"(55)
2-3/8"(60)
2-3/4"(70)
2-15/16"(75)
2-15/16"(75)
3-1/4"(82)
4-9/32"(109)
4-1/4"(108)
4-1/2"(114)
4-1/2"(114)
M A L E T O F E M A L E
UNY11
UNY21
UNY31
UNY4
UNY5
UNY6
UNY7
UNY8
UNY9
UNY0
DIMENSIONSHUB S IZE
9 0 ° A N G L E U N I O N
1/2"
3/4"
GUML-1M
GUML-2M
GUML-1
GUML-2
Dimensions
1-1/2"(38)
1-3/4"(44)
2"(51)
2-3/8"(60)
2-5/8"(67)
3-1/4"(82)
4-1/2"(114)
5-3/8"(136)
6-1/4"(159)
6-1/4"(159)
GUM-11
GUM-21
GUM-31
GUM-4
GUM-5
GUM-6
GUM-7
GUM-8
GUM-9
GUM-0
Applications• UNY and UNF unions are used to
connect two pieces of conduit orattach conduit to junction boxes, fittings, or devices
• Permits removal of equipment with-out turning or removal of conduit
Features• Threaded for rigid conduit or IMC
• Tapered threads (NPT)
• Strong and durable construction
Material/Finish
Copper-free Aluminum — 1/2"- 4"(less than 4/10 of 1%)
• Natural Finish
Iron — 1-1/4"- 4"
Steel — 1/2", 3/4", 1"
• Zinc electro-plate
Third-Party Standards• UL Standard 886
• CSA Standard C22.2 No. 30
GUF GUM
1-1/2"(38)
1-3/4"(44)
2"(51)
2-3/8"(60)
2-5/8"(67)
3-1/4"(82)
4-1/2"(114)
5-3/8"(136)
6-1/4"(159)
6-1/4"(159)
1-7/8"(48)
1-15/16"(49)
2-7/16"(62)
2-1/2"(63)
2-1/2"(63)
2-5/8"(67)
3-3/32"(78)
3-1/16"(78)
3-9/16"(90)
3-9/16"(90)
2-1/2"(64)
2"(51)
1-1/2"(38)
1-1/2"(38)
1-3/4"(44)
1-5/8"(42)
KILLARKALUM.
DURALOYIRON
KILLARKALUM.
DURALOYIRON
CATALOG NUMBER
A B C
A DIAMETER B LENGTH
GUF-8 GUM-2 GUML-2
GUML-2MUNY2UNY4UNF2
GUF-2
UNF/UNY SERIES • F ITTINGSEXPANSION CONDUIT UNIONS
F63
FEATURES-SPECIFICATIONS
F
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
DIMENSIONS
A B C
HUB S IZE
CATALOG NU MBER
F E M A L E – S H O R T
1/2"
3/4"
1"
UNFS & UNYS — Standard LengthUNFL & UNYL — Long Length
Application• To provide for slight expansion and
contraction of conduit runs
• To retrofit sections of conduit runs
Features• Tapered threaded hubs (NPT) for
rigid conduit and IMC
• Telescoping components allowsconduit to be inserted betweenfixed threaded hubs
• Internal copper alloy groundingspring assures positive grounding
• Close tolerance of mating partseliminates passage of flame
• Compact diameter allows usewhere conduit is closely spaced
• Available in standard and longstyle, male and female version
Material/FinishBody/Sleeve — Steel/ZincElectroplate
Grounding Spring — BerylliumCopper/Natural Finish
UNFS Type Female/Female UNFL Type Female/Female
UNYS Type Male/Female UNYL Type Male/Female
MAXIMUM LENGTH MAXIMUM LENGTH DIAMETER
UNFS1
UNFS2
UNFS3
3.34 (85)
3 .53 (90)
3 .69 (94)
2 .84 (72)
2 .97 (75)
3 .08 (78)
1 .19 (30)
1 .44 (37)
1 .69 (43)
DIMENSIONS
A B C
HUB S IZE
CATALOG NUMBER
F E M A L E – L O N G
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNFL1
UNFL2
UNFL3
4.34 (110)
4 .53 (115)
4 .69 (119)
3 .34 (85)
3 .47 (88)
4 .58 (116)
1 .19 (30)
1 .44 (37)
1 .69 (43)
DIMENSIONS
A B C
HUB S IZE
CATALOG NUMBER
M A L E – S H O R T
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNYS1
UNYS2
UNYS3
3.30 (84)
3 .41 (87)
3 .57 (91)
2 .80 (71)
2 .85 (72)
2 .97 (75)
1 .19 (30)
1 .44 (37)
1 .69 (43)
DIMENSIONS
A B C
HUB S IZE
CATALOG NUMBER
M A L E – L O N G
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNYL1
UNYL2
UNYL3
4.30 (109)
4 .41 (112)
4 .57 (117)
3 .30 (84)
3 .35 (85)
3 .47 (88)
1 .19 (30)
1 .44 (37)
1 .69 (43)
UNFS UNFL UNYS UNYL
Class I, Div. 1 & 2, Groups C,DClass I, Zone 1, Groups IIB, IIAClass II, Div. 1 & 2, Groups E,F,GClass III
UL Standard 886
CSA Standard C22.2 No. 30
Mil Spec: MIL-F28675
Dimensions
CUP/PLUG/AN SERIES • F ITTINGSTHREADED INSERT PLUGS AND RIGID CONDUIT NIPPLES
F64
FEATURES-SPECIFICATIONS
CUP-0
CUP/PLUGApplications
• To close up a taped hole or hub
Features• Threaded hubs (NPT)
Material/FinishCopper-free Aluminum — 1/4"- 4"(less than 4/10 of 1%)
• Natural Finish
Steel — 1/2"- 1"
• Zinc Plated
Iron — 1-1/4"- 4"
• Zinc Plated
HUB SIZE
R E C E S S E D P L U G
CATALOG NUMBER
• CUP/CUPX/PLUG 1, 2, & 3,PLUG 1, 2, & 3-SQ Class I Groups A,B,C,DClass I, Zone 1, Groups IIC, IIB, IAClass II Groups E,F,G
• CUP/CUPX/PLUG 1 1/4" through 4"Class I, Groups C,DClass I, Zone 1, Groups IIB, IIAClass II Groups E,F,G
UL Standard: 886
CSA Standard: C22.2 No. 30
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR11716
S Q U A R E H E A D P L U G
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/4"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CUP-1 to 5
CUP-375
CUP-6 to 9
PLUG375
PLUG1
PLUG2
PLUG3
PLUG4
PLUG5
PLUG6
PLUG7
PLUG8
PLUG9
PLUG10
CUP-375
CUP-1
CUP-2
CUP-3
CUP-4
CUP-5
CUP-6
CUP-7
CUP-8
CUP-9
CUP-0
CUPX-250
CUPX-1
CUPX-2
CUPX-3
CUPX-4
CUPX-5
CUPX-6
CUPX-7
CUPX-8
CUPX-9
CUPX-0
STEEL / IRONKILLARK ALUMINUM
HUB SIZE
CATALOG NUMBER
STEEL / IRONKILLARK ALUMINUM
—
PLUG1-SQ
PLUG2-SQ
PLUG3-SQ
PLUG4-SQ
PLUG5-SQ
PLUG6-SQ
PLUG7-SQ
PLUG8-SQ
PLUG9-SQ
PLUG10-SQ
CUPX-250
Square Head
AN
Applications
• To connect threaded on IMCconduit to cast hubs on drilled andtapped conduit openings
Features• Tapered threads (NPT)
Material/FinishCopper-free Aluminum(less than 4/10 of 1%)
CONDUIT SIZE
R I G I D C O N D U I T N I P P L E S
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5"
6"
AN-1
AN-2
AN-3
AN-4
AN-5
AN-6
AN-7
AN-8
AN-9
AN-10
AN-11
AN-12
AN-1A
—
—
—
—
—
—
—
—
—
—
—
AN-1B
AN-2B
AN-3B
—
—
—
—
—
—
—
—
—
CATALOG NUMBERCLOSE
1-1/8"
1-3/8"
1-1/2"
1-5/8"
1-3/4"
2"
2-1/2"
2-5/8"
2-3/4"
2-7/8"
3"
3-1/8"
1-1/2"
—
—
—
—
—
—
—
—
—
—
—
2"
2"
2"
—
—
—
—
—
—
—
—
—
BODY LENGTH BODY LENGTH BODY LENGTH1-1/2" LONG 2" LONG
AN-1 to 5AN-3B AN-6 up
KDB/KB/KSBF SERIES • F ITTINGSDRAINS & BREATHERS
F65
FEATURES-SPECIFICATIONS
FKDB/KB
Applications
• When installed in the top of anenclosure, these fittings act asbreathers
• Bottom installations permit water to drain from the enclosure continuously
• All drains and breathers aredesigned for use in 1/2" hubs or1/2" drilled and tapped conduitopenings
• KDB-1 can be used as a drain or breather
Features• Tapered threads (NPT)
Material/FinishStainless Steel
KSBF
Applications
• When installed in the top of anenclosure, these fittings act asbreathers
• Bottom installations permit water to drain from the enclosure continuously
• KSBF breathers and drains aredesigned for punched M25 entriesin standard location or Ex e sheetmetal or non-metallic enclosures
Features• M25 x 1.5 metric threads
• Includes notched locknut
Material/Finish• Polyamide
• Green in color
D R A I N S A N D B R E AT H E R S
CATALOG NUMBER DESCRIPTION SUITABILITIES
CLASS I Div. 1 & 2 , Groups C, DCLASS I I D iv. 1 & 2 , Groups E , F, GCLASS I I I
CLASS I Div. 1 & 2 , Groups B, C, DCLASS I I D iv. 1 & 2, Groups E , F, GCLASS I I I
CLASS I Div. 1 & 2 , Groups B, C, DCLASS I I D iv. 1 & 2 , Groups E , F, GCLASS I I I
Dra in or Brea ther
Brea ther (Group B)
Dra in (Group B)
KDB-113
KB1B13
KB1D23
KDB-1 KB1B KB1D
1UL Listed and CSA Certified
2UL Listed only
3FM Approved
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
Fi le 25215
See f i les for de ta i ls or ca l l K i l la rk .
FM
APPROVED
KSBF-M25
CATALOG NUMBER(INCLUDES LOCKNUT) THREAD SIZE
M25 x 1 .5
KSBF
NON-METALLIC DRAINS AND BREATHERS—E E x e I I , I P 5 4 R AT E D
Class I, Div. 1 & 2, Groups C,D Class II, Div. 1 & 2, Groups E,F,GClass III
PTB Ex-95.D.3148U
Cal l fo r de ta i ls
EEx e llEx e ll
R/RE/ADUP SERIES • F ITTINGSREDUCING BUSHINGS AND ADAPTERS
F66
FEATURES-SPECIFICATIONS
UL Standard: 886
CSA Standard: C22.2 No. 30
Lis ted F i le No. E 10514
Cer t i f i ed F i le No. LR117161" – 3/4" 2" – 1-1/2" ADUP
Application• To reduce the trade size of a
taped hole or hub.
Features• Tapered threads (NPT)
• Smooth internal bushing protectsconductors
• Threaded for Rigid Conduit or IMC
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)(R-10 through R-109)
Natural Finish
Steel/Zinc Plated(RE21S through RE65S)
HUB SIZECATALOG NUMBER DIMENSIONS
R E D U C I N G B U S H I N G S
BODY LENGTH
• R-10 through R-65• RE21S through RE65S
Class I, Div. 1 & 2, Groups A,B,C,DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E,F,G
• R-73 through R-109Class I, Div. 1 & 2, Groups A,B,C,DClass I, Zone 1, Groups IIC, IIB, IIAClass II, Div. 1 & 2, Groups E,F,G
1/2" — 3/8"
3/4" — 3/8"
3/4" — 1/2"
1" — 3/8"
1" — 1/2"
1" — 3/4"
1-1/4" — 1/2"
1-1/4" — 3/4"
1-1/4" — 1"
1-1/2" — 1/2"
1-1/2" — 3/4"
1-1/2" — 1"
1-1/2" — 1-1/4"
2" — 1/2"
2" — 3/4"
2" — 1"
2" — 1-1/4"
2" — 1-1/2"
2-1/2" — 1"
2-1/2" — 1-1/2"
2-1/2" — 2"
3" — 1-1/2"
3" — 2"
3" — 2-1/2"
3-1/2" — 2-1/2"
3-1/2" — 3"
4" — 2"
4" — 2-1/2"
4" — 3"
4" — 3-1/2"
R-10
R-20
R-21
R-30
R-31
R-32
R-41
R-42
R-43
R-51
R-52
R-53
R-54
R-61
R-62
R-63
R-64
R-65
R-73
R-75
R-76
R-85
R-86
R-87
R-97
R-98
R-106
R-107
R-108
R-109
—
—
RE21S
—
RE31S
RE32S
RE41S
RE42S
RE43S
RE51S
RE52S
RE53S
RE54S
RE61S
RE62S
RE63S
RE64S
RE65S
—
—
—
—
—
—
—
—
—
—
—
—
KILLARKALUM. STEEL
5/8"(16)
7/8"(22)
23/32"(18)
7/8"(22)
23/32"(18)
23/32"(18)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
7/8"(22)
7/8"(22)
7/8"(22)
7/8"(22)
7/8"(22)
1"(25)
1"(25)
1"(25)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-3/8"(35)
1-3/8"(35)
1-1/2"(38)
1-1/2"(38)
1-1/2"(38)
1-1/2"(38)
A D U P A D A P T E R S
CATALOG NUMBER1 DESCRIPTION
ADUP-01
ADUP-12
MALE 3/8
FEMALE 1/2
MALE 1/2
FEMALE 3/4
1Series ADUP suitable for Class I, Groups A,B,C,D
Material/Finish
Copper-free Aluminum(less than 4/10 of 1%)
Natural Finish
FF/MF/MM/BL/GUFS/Y/EYMF SERIES • F ITTINGSELBOWS
F67
FEATURES-SPECIFICATIONS
F
Y EYMF
Class I, Div. 1 & 2, Groups C,D Class II, Div. 1 & 2, Groups E,F,GClass III
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
Fi le 25215
See f i les for de ta i ls or ca l l K i l la rk .
FM
APPROVED
FF
Female/Female
MF
Male/Female
MM
Male/Male
BL
Male/Female
GUFS
E L B O W S
FF-90-11FF-90-21FF-90-31FF-45-11FF-45-21FF-45-31FF-45-61MF-90-11MF-90-21MF-45-11MF-45-21MM-90-11MM-90-21BL-90-11BL-90-21BL-90-31
FF-90-1M3FF-90-2M3FF-90-3M3FF-45-1M3FF-45-2M3FF-45-3M3FF-45-6M3MF-90-1M3MF-90-2M3MF-45-1M3MF-45-2M3MM-90-1M3MM-90-2M3BL-90-1M3BL-90-2M3BL-90-3M3
CATALOG NUMBERALUMINUM
FF
90°
FF
45°
MF
90°
MF
45°
MM
90°
BL
90°
1/2"
3/4"
1"
1/2"
3/4"
1"
2"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1"
2"
2-1/4"
2-15/16"
2-3/8"
2-11/16"
3-3/8"
4-3/4"
11/16"
7/8"
2-1/8"
2-3/8"
2-1/16"
2-1/4"
2-1/4"
2-5/8"
2-1/4"
2"
2-1/4"
2-15/16"
2"
2-3/16"
2-11/16"
3-7/8"
2"
2-7/16"
1-3/4"
1-7/8"
2-1/16"
2-1/4"
2-3/8"
3"
3-7/16"
1-3/8"
1-1/2"
2"
1-1/8"
1-1/4"
1-5/8"
2-1/4"
1-3/8"
1-1/2"
1-1/8"
1-9/32"
1-3/8"
1-1/2"
1-7/8"
2-1/8"
2-5/8"
1-3/8"
1-1/2"
2"
—
—
—
—
1-3/8"
1-11/16"
3/4"
3/4"
1-3/8"
1-1/2"
1-3/4"
2-1/4"
2-1/2"
IRON TYPEHUBSIZE A B C D
C A P P E D E L B O W S
Y-1M4Y-2M4Y-3M4Y-4M4Y-5M4
CATALOG NUMBERALUMINUM
90°
90°
90°
90°
90°
1/2"
3/4"
1"
1-1/4"
1-1/2"
2-7/8"
3-1/16"
4"
5-1/16"
5-1/16"
2-3/4"
3-3/4"
3-1/4"
4-1/8"
4-1/4"
1-7/8"
2-1/8"
2-5/8"
3-7/8"
3-7/8"
—
—
—
—
—
IRON TYPEHUBSIZE A B C D
Y-11Y-21Y-31Y-41Y-51
S W I V E L E L B O W S
CATALOG NUMBERALUMINUM
180°
180°
180°
180°
1/2"
3/4"
1/2"
3/4"
4-1/2"
4-1/2"
5-1/8"
5-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
—
—
—
—
—
—
—
—
IRONTYPEHUB
SIZE A B C D
GUFS-12GUFS-22GUMFS-12GUMFS-22
GUFS-1M3GUFS-2M3GUMFS-1M3GUMFS-2M3
9 0 ° P L U G G E D E L B O W S
CATALOG NUMBER5ALUMINUM
90°
90°
1/2"
3/4"
2-5/8"
2-3/4"
2-5/8"
2-3/4"
1-3/8"
1-1/2"
1-3/8"
1-1/2"
IRONTYPEHUB
SIZE A B C D
EYMF-12EYMF-22
——
Applications• Elbows: To change direction in
rigid or IMC conduit systems
• Capped Elbows: To change direc-tion 90° in rigid or IMC conduitsystems where space is limitedand access is needed for pullingconductors or maintenance
• Swivel Elbows: Allows conduit tobe joined at angles rangingbetween 90° to 180°. A screwdriveris the only tool needed
• 90° Plugged Elbows: To changedirection 90° in rigid or IMC con-duit systems where space is limitedand access is needed for pullingconductors or maintenance
Features• Threaded for rigid conduit or IMC
• Smooth integral bushings to pre-vent damage to wires
Material/FinishCopper-free Aluminum (less than 4/10 of 1%)
• Electrostatically applied powdercoating
Iron Zinc electro-plate
1Copper-free aluminum - Electrostatically applied powder coating
2Aluminum - Natural finish
3Iron - Zinc electroplate
4Iron - Duraloy finish
5Furnished with 1" close-up plug in top.
F68
FEATURES-SPECIFICATIONS
E C F / E K J F L E X I B L E C O U P L I N G S
CDIA.
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
M I N I M U M B E N D R A D I U S
E C F / E K J F L E X I B L E C O U P L I N G S ApplicationsFor use in hazardous areas wheremovement or vibration requires aflexible connection or a difficult bendis required in a conduit system.
Features• Bronze flexible metal construction
• An inner liner of asphaltum impreg-nated jute fibre tubing to protect conductors
• Female ends with zinc plated steelnipples standard on all couplings
• Union type couplings may beassembled by adding a GUF Seriesunion to the nipple
• Special lengths available-consult factory
• All 1/2", 3/4" & 1" EKJ couplings arefurnished with a setscrew (for use asa fixture hanging coupling)
SERIES 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"
ECF 10" 12" 14" – – –
EKJ 10" 12" 14" 14" 16" 18"
ECF CONDUITSERIES SIZE
ECF-14 1/2"
ECF-16 1/2"
ECF-18 1/2"
ECF-110 1/2"
ECF-112 1/2"
ECF-115 1/2"
ECF-118 1/2"
ECF-121 1/2"
ECF-124 1/2"
ECF-130 1/2"
ECF-136 1/2"
ECF-24 3/4"
ECF-26 3/4"
ECF-28 3/4"
ECF-210 3/4"
ECF-212 3/4"
ECF-215 3/4"
ECF-218 3/4"
ECF-221 3/4"
ECF-224 3/4"
ECF-230 3/4"
ECF-236 3/4"
ECF-36 1"
ECF-38 1"
ECF-310 1"
ECF-312 1"
ECF-315 1"
ECF-318 1"
ECF-321 1"
ECF-324 1"
ECF-330 1"
ECF-336 1"
EKJ-14
EKJ-16
EKJ-18
EKJ-110
EKJ-112
EKJ-115
EKJ-118
—
—
—
—
EKJ-24
EKJ-26
EKJ-28
EKJ-210
EKJ-212
EKJ-215
EKJ-218
—
—
—
—
EKJ-36
EKJ-38
EKJ-310
EKJ-312
EKJ-315
EKJ-318
EKJ-321
EKJ-324
EKJ-330
EKJ-336
CONDUITSIZE
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
BFLEX.
LENGTH
12"
15"
18"
21"
24"
30"
36"
12"
15"
18"
21"
24"
30"
36"
12"
15"
18"
24"
30"
36"
AOVERALLLENGTH
18-5/8"
21-5/8"
24-5/8"
27-5/8"
30-5/8"
36-5/8"
42-5/8"
18-15/16"
21-15/16"
24-15/16"
27-15/16"
30-15/16"
36-15/16"
42-15/16"
19-5/16"
22-5/16"
25-5/16"
31-5/16"
37-5/16"
43-5/16"
EKJ-412
EKJ-415
EKJ-418
EKJ-421
EKJ-424
EKJ-430
EKJ-436
EKJ-512
EKJ-515
EKJ-518
EKJ-521
EKJ-524
EKJ-530
EKJ-536
EKJ-612
EKJ-615
EKJ-618
EKJ-624
EKJ-630
EKJ-636
EKJSERIES
EKJSERIES
1ECF & EKJ 1/2" and 3/4" couplingssuitable for Class I, Groups A,B,C,DClass l, Zone 1, Groups llC, llB, llAEKJ 1" thru 2" and ECF 1" couplingssuitable for Class I, Groups C,D. Classl, Zone 1, Groups llB, llAAll ECF and EKJ are suitable for Class II and Ill.
BFLEX.
LENGTH
4"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
4"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
AOVERALLLENGTH
8-13/16"
10-13/16"
12-13/16"
14-13/16"
16-13/16"
19-13/16"
22-13/16"
25-13/16"
28-13/16"
34-13/16"
40-13/16"
8-3/4"
10-3/4"
12-3/4"
14-3/4"
16-3/4"
19-3/4"
22-3/4"
25-3/4"
28-3/4"
34-3/4"
40-3/4"
11-3/4"
13-3/4"
15-3/4"
17-3/4"
20-3/4"
23-3/4"
26-3/4"
29-3/4"
35-3/4"
41-3/4"
CATALOG NUMBER DESCRIPTION CAT. NO. DESCRIPTION
CDIA.
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
Class I, Div. 1 & 2, Groups A,B,C,D1
Class l, Zone 1, Groups llC, llB, llAClass II, Div. 1 & 2, Groups E,F,GClass IIIRaintight
ECF
1/2", 3/4", 1"
EKJ
1/2", 3/4", 1"
EKJ
1-1/4", 1-1/2", 2"
ECF/EKJ SERIES • F ITTINGSBRONZE FLEXIBLE COUPLINGS
ECLK SERIES • F ITTINGSBRONZE FLEXIBLE COUPLINGS WITH FEMALE STEEL UNION
F69
F
FEATURES-SPECIFICATIONS
E C L K F L E X I B L E C O U P L I N G S
CDIA.
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
M I N I M U M B E N D R A D I U S
E C L K F L E X I B L E C O U P L I N G S
Lis ted - F i le E10514
Cer t i f i ed - F i le LR11716
See f i les for de ta i ls or ca l l K i l la rk .
ApplicationsFor use in hazardous areaswhere movement or vibra-tion requires a flexible con-nection or a difficult bendis required in aconduit system.
Features• Bronze flexible metal
construction
• An inner liner of asphal-tum impreg-nated jutefibre tubing to protectconductors
• Provided with one zinkplated steel nipple andone zink plated steelfemale union
• Special lengths available-consult factory
SERIES 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"
ECF 10" 12" 14" – – –
EKJ 10" 12" 14" 14" 16" 18"
ECLK CONDUITSERIES SIZE
ECFUF-14 1/2"
ECFUF-16 1/2"
ECFUF-18 1/2"
ECFUF-110 1/2"
ECFUF-112 1/2"
ECFUF-115 1/2"
ECFUF-118 1/2"
ECFUF-121 1/2"
ECFUF-124 1/2"
ECFUF-130 1/2"
ECFUF-136 1/2"
ECFUF-24 3/4"
ECFUF-26 3/4"
ECFUF-28 3/4"
ECFUF-210 3/4"
ECFUF-212 3 ⁄4"
ECFUF-215 3/4"
ECFUF-218 3/4"
ECFUF-221 3/4"
ECFUF-224 3/4"
ECFUF-230 3/4"
ECFUF-236 3/4"
ECFUF-36 1"
ECFUF-38 1"
ECFUF-310 1"
ECFUF-312 1"
ECFUF-315 1"
ECFUF-318 1"
ECFUF-321 1"
ECFUF-324 1"
ECFUF-330 1"
ECFUF-336 1"
CONDUITSIZE
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
BFLEX.
LENGTH
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
12" (305)
15" (381)
18" (457)
24" (610)
30" (762)
36" (914)
AOVERALLLENGTH
20-1/4" (514)
21-1/4" (591)
24-1/4" (667)
27-1/4" (743)
30-1/4" (819)
36-1/4" (972)
42-1/4" (1124)
21-15/16" (557)
24-15/16" (633)
27-15/16" (710)
30-15/16" (786)
33-15/16" (862)
39-15/16" (1014)
45-15/16" (1167)
21-9/16" (548)
24-9/16" (624)
27-9/16" (700)
33-9/16" (852)
39-9/16" (1005)
45-9/16" (1157)
EKJUF-412
EKJUF-415
EKJUF-418
EKJUF-421
EKJUF-424
EKJUF-430
EKJUF-436
EKJUF-512
EKJUF-515
EKJUF-518
EKJUF-521
EKJUF-524
EKJUF-530
EKJUF-536
EKJUF-612
EKJUF-615
EKJUF-618
EKJUF-624
EKJUF-630
EKJUF-636
ECLKSERIES
Class I, Div. 1 & 2, Groups A,B,C,D1
Class l, Zone 1, Groups llC, llB, llAClass II, Div. 1 & 2, Groups E,F,GClass IIIRaintight
11/2" and 3/4" couplingssuitable for:
• Class I, Groups A,B,C,DClass l, Zone 1, GroupsllC, llB, llA.
• 1" couplings suitable for:Class I, Groups C,D.Class l, Zone 1, GroupsllB, llA.
• All ECLK couplings aresuitable for:Class II and Ill.
BFLEX.
LENGTH
4" (102)
6" (152)
8" (203)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
4" (102)
6" (152)
8" (203)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
6" (102)
8" (152)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
AOVERALLLENGTH
10-1/8" (257)
12-1/8" (310)
14-1/8" (359)
16-1/8" (410)
18-1/8" (460)
21-1/8" (537)
24-1/8" (613)
27-1/8" (689)
30-1/8" (765)
36-1/8" (918)
42-1/8" (1070)
10-1/4" (260)
12-1/4" (311)
14-1/4" (362)
16-1/4" (413)
18-1/4" (464)
21-1/4" (540)
24-1/4" (616)
27-1/4" (692)
30-1/4" (768)
36-1/4" (921)
42-1/4" (1073)
13-3/16" (335)
15-3/16" (386)
17-3/16" (437)
19-3/16" (487)
22-3/16" (564)
25-3/16" (640)
28-3/16" (716)
31-3/16" (792)
37-3/16" (945)
43-3/16" (1097)
CAT. NO. DESCRIPTION CAT. NO. DESCRIPTION
ECFUF
1/2", 3/4", 1"
EKJUF
1-1/4", 1-1/2", 2"
CDIA.
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
ECFUF 1/2", 3/4", 1" EKJUF 1-1/4", 1-1/2", 2"
EKJ SERIES • F ITTINGSSTAINLESS STEEL FLEXIBLE COUPLINGS
F70
FEATURES-SPECIFICATIONS
Features• Available in custom lengths.
See catalog logic to order
• Stainless steel wirebraid construction
• Annular corrugated seamless hose
• Cast in ribs for easy installation
• 1/2" – 2" sizes furnished with twozinc plated steel nipples
• 2-1/2" – 4" sizes furnished with twoaluminum nipples
Cer t i f ied - F i le LR11716
1See f i les for de ta i ls or ca l l K i l la rk .
F i le J IOE3H1.AEFM
APPROVED
EKJ 2 12
2410
SS
Series Stainless Steel
Trade Size
1/2" — 1
3 /4" — 2
1" — 3
1-1 /4" — 4
1-1 /2" — 5
2" — 6
Braid Length
(Specify in whole inches)
examples 12" — 12
24" — 24
Sizes 1/2" Thru 2"
Trade Size
2-1/2" — 7
3" — 8
4" — 10
Braid Length
(Specify in whole inches)
examples 12" — 12
24" — 24
Sizes 2-1/2" Thru 4"
Ordering Example - EKJS-1024
(4" trade size, 24" length)
Ordering Example - EKJ-212 SS
(3/4" trade size, 12" length)
EKJ S
Series
Stainless Steel
Class I, Div. 1 & 2, Groups C, D1
Class I, Zone 1, Groups llB, llA1
Class II, Div. 1 & 2, Groups E, F, GClass III
Catalog Number Logic
EKJ
1/2"-2"
EKJ
2-1/2"-4"
K SERIES • F ITTINGSLIQUIDTIGHT CONNECTORS
F71
FEATURES-SPECIFICATIONS
FLIQUIDTIGHT ®
ApplicationsUse with metallic and non-metallicconduit to seal out water, oil and dustin applications for food processors,beverage & chemical plants, plasticsfabricators, machine shops, etc.
Liquidtight connectors are also suit-able for use in hazardous locationapplications when installed accordingto NEC Articles 501.10(b), Class I,Div. 2, (Suitable for use in Class IZone 2 applications) 502.10 and503.10. Consult these articles forsealing requirements that may apply.
Liquidtight mesh grips provide a liquidtight seal and enhanced strainrelief in flexible liquidtight conduitapplications.
Features• Split nylon gland ring – split for
easy installation and greater com-pression
• Digging locknut
• Sealing ‘O’-rings included
• Reusable
Materials/Finish• Steel/malleable iron
• Zinc electro-plated
Mesh Grips• Stainless steel mesh grips are
corrosion resistant and preventconduit pull-out in high stressinstallations
Lis ted - F i le E22699
Cer t i f i ed - F i le LR70873
See f i les for de ta i ls or ca l l K i l la rk .K2001 K0751-MG
DIMENSIONSA B C
1-7/16" 19/32" 1-1/16"
1-7/16" 19/32" 1-13/16"
1-9/16" 19/32" 1-3/8"
1-11/16" 21/32" 1-11/16"
2-1/32" 11/16" 2-1/16"
2-7/32" 11/16" 2-3/8"
2-9/32" 23/32" 2-7/8"
3-1/2" 1" 3-5/8"
3-3/4" 1" 4-5/16"
3-3/4" 1" 4-3/4"
3-3/4" 1" 5-5/16"
1-7/16" 21/32" 1-1/16"
1-7/16" 21/32" 1-3/16"
1-5/8" 21/32" 1-3/8"
1-3/4" 23/32" 1-11/16"
2-3/32" 3/4" 2-1/16"
2-9/32" 3/4" 2-3/8"
2-11/32" 25/32" 2-7/8"
3-1/2" 1" 3-5/8"
3-3/4" 1" 4-5/16"
3-3/4" 1" 4-3/4"
3-3/4" 1" 5-5/16"
CATALOG NUMBER
K038
K050
K075
K100
K125
K150
K200
K250
K300
K350
K400
K0381*
K0501*
K0751*
K1001*
K1251*
K1501*
K2001*
K2501*
K3001*
K3501
K4001*
NPTSIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
St ra ight non- insula ted
CONNECTORSTYLE
Stra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
St ra ight insula ted
K L I Q U I D T I G H T C O N N E C T O R S — S T R A I G H T
Dimensions
*For mesh grip, add - MG to Catalog Number. Example K0381-MG.
K SERIES • F ITTINGSLIQUIDTIGHT CONNECTORS
F72
FEATURES-SPECIFICATIONS
K2004
45° Non-Insulated
K20041
45° Insulated
CATALOG NUMBER
K0389
K0509
K0759
K1009
K1259
K1509
K2009
K2509**
K3009
K4009
K03891*
K05091*
K07591*
K10091*
K12591*
K15091*
K20091*
K25091*
K30091*
K40091*
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
90° non- insula ted
CONNECTORSTYLE
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
90° Insula ted
K L I Q U I D T I G H T C O N N E C T O R S — 9 0 ° B E N D
K L I Q U I D T I G H T C O N N E C T O R S — 4 5 ° B E N D
DIMENSIONSD E F G
1-1/2" 5/8" 1" 1-3/4"
1-1/2" 5/8" 1-1/8" 1-3/4"
1-19/32" 5/8" 1-3/8" 1-15/16"
1-3/16" 5/8" 1-5/8" 2-3/16"
2" 11/16" 2-1/16" 2-9/16"
2-3/16" 11/16" 2-3/8" 3"
2-17/32" 23/32" 2-7/8" 3-5/8"
3-3/8" 1" 3-5/8" 4-1/4"
3-11/16" 1" 4-5/16" 4-7/8"
4-3/16" 1" 5-5/16" 5-5/8"
1-9/16" 11/16" 1" 1-3/4"
1-9/16" 11/16" 1-1/8" 1-3/4"
1-21/32" 11/16" 1-3/8" 1-15/16"
1-7/8" 11/16" 1-5/8" 2-3/16"
2-1/16" 3/4" 2-1/16" 2-9/16"
2-1/4" 3/4" 2-3/8" 3"
2-19/32" 25/32" 2-7/8" 3-5/8"
3-3/8" 1" 3-5/8" 4-1/4"
3-11/16" 1" 4-5/16" 4-7/8"
4-3/16" 1" 5-5/16" 5-5/8"
CATALOG NUMBER
K0384
K0504
K0754
K1004
K1254
K1504
K2004
K03841*
K05041*
K07541*
K10041*
K12541*
K15041*
K20041*
NPTSIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
45° non- insula ted
45° non- insula ted
45° non- insula ted
45° non- insula ted
45° non- insula ted
45° non- insula ted
45° non- insula ted
CONNECTORSTYLE
45° Insula ted
45° Insula ted
45° Insula ted
45° Insula ted
45° Insula ted
45° Insula ted
45° Insula ted
DIMENSIONSH J K L
1-5/32" 1-9/32" 19/32" 1"
1-5/32" 1-9/32" 19/32" 1-1/8"
1-11/64" 1-7/16" 19/32" 1-3/8"
1-13/32" 1-23/32" 21/32" 1-5/8"
1-27/64" 2-1/32" 5/8" 2-1/16"
1-21/32" 1-15/16" 21/32" 2-3/8"
1-11/16" 2-7/16" 21/32" 2-7/8"
1-7/32" 1-9/32" 21/32" 1"
1-7/32" 1-9/32" 21/32" 1-1/8"
1-15/64" 1-7/16" 21/32" 1-3/8"
1-15/32" 1-23/32" 23/32" 1-5/8"
1-31/64" 2-1/32" 11/16" 2-1/16"
1-23/32" 1-15/16" 23/32" 2-3/8"
1-3/4" 2-7/16" 23/32" 2-7/8"
LIQUIDTIGHT ®
ApplicationsUse with metallic and non-metallicconduit to seal out water, oil and dustin applications for food processors,beverage & chemical plants, plasticsfabricators, machine shops, etc.
Liquidtight connectors are also suit-able for use in hazardous locationapplications when installed accordingto NEC Articles 501.10(b), Class I,Div. 2, (Suitable for use in Class IZone 2 applications) 502.10 and503.10. Consult these articles forsealing requirements that may apply.
Features• Split nylon gland ring – split for easy
installation and greater compression
• Digging locknut
• Sealing ‘O’-rings included
• Reusable
Materials/Finish• Steel/malleable iron
• Zinc electro-plated
Dimensions
K0759
90° Non-Insulated
K07591-MG K20041-MG
K07591
90° Insulated
*For mesh grip, add -MG to Catalog Number. Example K03891-MG.
** Use K25091 insulated.
Lis ted - F i le E22699
Cer t i f i ed - F i le LR70873
See f i les for de ta i ls or ca l l K i l la rk .
NPTSIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
K SERIES • F ITTINGSGROUNDED LIQUIDTIGHT CONNECTORS
F73
FEATURES-SPECIFICATIONS
FLIQUIDTIGHT ®
K Grounding styleApplication & Installation
Liquidtight Connectors with ground-ing lug are for use where an external, visible equipment bonding jumper isdesired and where permitted by theNational Electrical Code. The Codespecifies length limitations and thatthe bonding jumper must be parallelto the conduit itself.
Lis ted - F i le E152165, E22699
Cer t i f i ed - F i le LR70873
See f i les for de ta i ls or ca l l K i l la rk .
Features• Lay-in grounding lug
• Fittings are plated steel for excel-lent durability
• Insulated throat fittings protect con-ductors from insulation damage
Materials/Finish• Steel/malleable iron
• Zinc electro-plated
90°Straight 45°
CONNECTOR ONLYNPTSIZE
DESC.
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2
2"
2-1/2”
3”
4”
3/8"
1/2"
3/4"
1"
1-1/4”
1-1/2"
2”
St ra ight
Insula ted
90°
Insula ted
45°
Insula ted
K L I Q U I D T I G H T G R O U N D I N G S T Y L E & M E S H G R I P S
CATALOG NUMBER DIMENSIONSA B C D E
1-1/16" 19/32" 1-7/16" 25/32" –
1-3/16" 19/32" 1-7/16" 25/32" –
1-3/8" 19/32" 1-9/16" 25/32" –
1-11/16" 21/32" 1-11/16" 25/32" –
2-1/16" 5/8" 2-1/32" 25/32" –
2-3/8" 5/8" 2-7/32" 25/32" –
2-7/8" 21/32" 2-9/32" 25/32" –
3-5/8" 1" 3-1/2" 1-11/64" –
4-15/16" 1" 3-3/4" 1-11/64" –
4-3/4" 1" 3-3/4" 1-57/64" –
5-5/16" 1" 3-3/4" 1-57/64" –
1-1/16" 19/32" 1-5/16" 1-7/16" 25/32"
1-3/16" 19/32" 1-5/16" 1-7/16" 25/32"
1-3/8" 19/32" 1-7/16" 1-5/8" 25/32"
1-11/16" 21/32" 1-25/32" 2-3/16" 25/32"
2-1/16" 5/8" 1-31/32" 2-1/2" 25/32"
2-3/8" 5/8" 2-3/16" 2-11/16" 25/32"
2-7/8" 21/32" 2-17/32" 3-1/4" 25/32"
3-5/8" 1" 3-3/8" 4-1/4" 1-11/64"
4-15/16" 1" 3-11/16" 4-7/8" 1-11/64"
5-5/16" 1" 4-3/16" 5-5/8" 1-57/64"
1-1/16" 19/32" 1-3/16" 1-9/32" 25/32"
1-3/16" 19/32" 1-3/16" 1-9/32" 25/32"
1-3/8" 19/32" 1-3/16" 1-7/16" 25/32"
1-11/16" 21/32" 1-3/8" 1-17/32" 25/32"
2-1/16" 5/8" 1-27/64" 1-11/16" 25/32"
2-3/8" 5/8" 1-21/32" 2" 25/32"
2-7/8" 21/32" 1-11/16" 2-1/4" 25/32"
K0381-G
K0501-G
K0751-G
K1001-G
K1251-G
K1501-G
K2001-G
K2501-G
K3001-G
K3501-G
K4001-G
K03891-G
K05091-G
K07591-G
K10091-G
K12591-G
K15091-G
K20091-G
K25091-G
K30091-G
K40091-GK03841-G
K05041-G
K07541-G
K10041-G
K12541-G
K15041-G
K20041-G
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
GROUNDING STYLE WIRE CAPACITY3/8" to 2" #14 sol id to #4 St randed
2-1/2" to 3" #14 sol id to #1/0 St randed
3-1/2" to 4" #6 s t randed to #250 MCM
Z SERIES • F ITTINGSALUMINUM CORD CONNECTORS
F74
FEATURES-SPECIFICATIONS
ApplicationsUse to secure and seal cords orcables entering enclosures or race-ways.
Z Series connectors are also suitablefor use in hazardous location applica-tions when installed according to NECArticles 501.10(b), Class I, Div. 2,(Suitable for use in Class I Zone 2applications) 502.10 and 503.10.Consult these articles for sealingrequirements that may apply.
Features• Aluminum construction resists
corrosion
• Neoprene grommet seals out oiland moisture
• Nylon retention ring ensures superi-or holding power
• Wide range of sizes and configura-tions
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .
.062-.125
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
1.688-1.812
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
2.437-2.625
2.625-2.812
2.812-3.000
3.000-3.250
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
Green
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
–
–
–
–
–
–
–
ZS001
ZS002
ZS003
ZS004
ZS006
ZS007
ZS101
ZS102
ZS103
ZS105
ZS108
ZS109
ZS110*
ZS111*
ZS201
ZS202
ZS203
ZS205
ZS208
ZS209
ZS210
ZS211*
ZS308
ZS309
ZS310
ZS311
ZS312
ZS313*
ZS314*
ZS315*
ZS411
ZS412
ZS413
ZS414
ZS415*
ZS511
ZS512
ZS513
ZS514
ZS515
ZS516
ZS517*
ZS518*
ZS520*
ZS615
ZS616
ZS617
ZS618
ZS620
ZS619
ZS621
ZS622*
ZS623*
ZS624*
ZS719
ZS721
ZS722
ZS723
ZS724
ZS725*
ZS819
ZS822
ZS823
ZS824
ZS825
ZS826
ZS827
ZS828
ZS829*
.99
.99
.99
.99
.99
.99
1.13
1.13
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
2.31
2.31
2.31
2.31
2.31
2.31
2.31
.90
.90
.90
.90
.90
.90
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
1.70
1.70
1.70
1.70
1.70
1.70
1.70
.425
.425
.425
.425
.425
.425
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.66
.66
.74
.74
.74
.74
.74
.453
.453
.453
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.255
1.255
1.255
1.255
1.255
2.31
2.31
2.31
2.31
2.31
3.00
3.00
3.00
3.00
3.25
3.25
3.25
3.25
3.25
4.06
4.06
4.06
4.06
4.06
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.87
4.87
4.87
4.87
1.70
1.70
1.70
1.70
1.70
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
.75
.75
.75
.75
.75
.75
.75
.75
.75
.80
.80
.80
.80
.80
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.30
1.30
1.30
1.30
1.30
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.50
1.50
1.50
1.50
1.92
1.92
1.92
1.92
1.92
1.94
1.94
1.94
1.94
1.94
2.34
2.34
2.34
2.34
2.34
2.34
2.54
2.54
2.54
2.54
2.54
3.00
3.00
3.00
3.00
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
3"
3"
3"
3"
3"
3"
3"
3"
3"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
Z C O R D C O N N E C T O R S — S T R A I G H T Z C O R D C O N N E C T O R S — S T R A I G H T
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
CATALOG NPT CORD DIMENSIONSNUMBER SIZE RANGES A B C D
CATALOG NPT CORD COLOR DIMENSIONSNUMBER SIZE RANGES CODE A B C D
ZS108
Locknut
(See page F71)
Z SERIES • F ITTINGSALUMINUM CORD CONNECTORS
F75
FEATURES-SPECIFICATIONS
FO P T I O N A L L O C K N U T S A N D S E A L I N G W A S H E R S
NPTSIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBERSTEEL SEALINGLOCKNUTS1 WASHERS2
LN375 —
LN1 KOR-1
LN2 KOR-2
LN3 KOR-3
LN4 KOR-4
LN5 KOR-5
LN6 KOR-6
LN7 —
LN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
2Neoprene washers are mounted on steel
reinforcing bands.
* Cable jacket may have to be stripped to
pass through connector body.
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.000-1.125
1.250-1.375
1.375-1.500
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Brown
Yellow
Purple
Gray
Pink
—
—
—
—
—
—
—
ZN102
ZN103
ZN105
ZN108
ZN109*
ZN208
ZN209
ZN210*
ZN211*
ZN309
ZN310
ZN311
ZN312*
ZN313*
ZN412
ZN413
ZN414*
ZN415*
ZN513
ZN515
ZN616
1.56
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.08
2.08
2.08
2.08
2.08
3.18
3.18
3.18
3.18
3.18
3.18
3.50
2.30
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
3.20
3.20
3.20
3.20
3.20
4.30
4.30
4.30
4.30
4.30
4.30
5.50
.50
.50
.50
.50
.50
.562
.562
.562
.562
.703
.703
.703
.703
.703
.73
.73
.73
.73
.75
.75
.80
.546
.546
.546
.546
.546
.765
.765
.765
.765
1.00
1.00
1.00
1.00
1.00
1.26
1.26
1.26
1.26
1.50
1.50
1.92
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
DIMENSIONSA B C D
Z C O R D C O N N E C T O R S — 9 0 º
ZN310
ApplicationsUse to secure and seal cords orcables entering enclosures or race-ways.
Z Series connectors are also suit-able for use in hazardous locationapplications when installed accord-ing to NEC Articles 501.10(b), ClassI, Div. 2, (Suitable for use in Class IZone 2 applications) 502.10 and503.10. Consult these articles forsealing requirements that mayapply.
Features• Aluminum construction resists
corrosion
• Neoprene grommet seals out oiland moisture
• Nylon retention ring ensures superior holding power
• Wide range of sizes and configu-rations
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
Locknut
Z SERIES • F ITTINGSALUMINUM CORD CONNECTORS WITH MESH GRIP
F76
FEATURES-SPECIFICATIONS
ApplicationsZ Series cord connector grips com-bine aluminum cord connectors withstainless steel mesh grips to providesuperior cord pull-out prevention inindoor and outdoor applications.These grips provide enclosure termi-nations where cords are subjected tomoisture or splashing water.
They are also suitable for use in haz-ardous location applications wheninstalled according to NEC Articles501.10(b), Class I, Div. 2, (Suitable foruse in Class I Zone 2 applications)502.10 and 503.10. Consult thesearticle for sealing requirements thatmay apply.
Features• Aluminum fittings are strong,
durable and corrosion resistant
• Internal grommet provides liq-uidtight seal
• Stainless steel mesh grips resistcorrosion, prevent cord pull-outand control arc-of-bend
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
• Stainless steel mesh grip
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .
O P T I O N A L L O C K N U T S A N D S E A L I N G W A S H E R S
NPTSIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBERSTEEL SEALINGLOCKNUTS1 WASHERS2
LN375 —
LN1 KOR-1
LN2 KOR-2
LN3 KOR-3
LN4 KOR-4
LN5 KOR-5
LN6 KOR-6
LN7 —
LN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
2Neoprene washers are mounted on steel
reinforcing bands.
.250-.312
.312-.375
.375-.437
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.00
1.00-1.125
Black
White
Blue
Red
White
Blue
Brown
Yellow
Purple
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS004-MG
ZS006-MG
ZS007-MG
ZS103-MG
ZS105-MG
ZS108-MG
ZS109-MG
ZS110-MG
ZS111-MG
ZS203-MG
ZS205-MG
ZS208-MG
ZS209-MG
ZS210-MG
ZS211-MG
ZS308-MG
ZS309-MG
ZS310-MG
ZS311-MG
ZS312-MG
ZS313-MG
.99
.99
.99
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
.90
.90
.90
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
.425
.425
.425
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
Z C O R D C O N N E C T O R S — S T R A I G H T
CATALOG NPT CORD COLOR DIMENSIONSNUMBER SIZE RANGES CODE A B C D
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
ZN103-MG
ZN105-MG
ZN108-MG
ZN109-MG
ZN208-MG
ZN209-MG
ZN210-MG
ZN211-MG
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
.50
.50
.50
.50
.562
.562
.562
.562
.546
.546
.546
.546
.765
.765
.765
.765
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
DIMENSIONSA B C D
Z C O R D C O N N E C T O R S — 9 0 º
LocknutZS310-MG
ZN210-MG
Z S T R A I G H T D I M E N S I O N S Z 90° D I M E N S I O N S
Z SERIES • F ITTINGSCORROSION RESISTANT NYLON CORD CONNECTORS
F77
FEATURES-SPECIFICATIONS
F
O P T I O N A L L O C K N U T S
ApplicationsDurable nylon construction makesthese connectors perfectly suited tocorrosive environments.
Typical applications for nylon cordconnectors include food processingfacilities, chemical and sewage treat-ment plants and off-shore and dock-side installations.
Features• Nylon retention ring for increased
holding power
• Neoprene bushing seals againstmoisture
• Nylon connectors obtain approxi-mately the same cord retention values with hand tightening that canbe produced only by wrench tight-ening of metal cord connectors
Material• Nylon
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .
CATALOG NPTNUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS — STRAIGHT
.125- .187
.187- .250
.250- .312
.312- .375
.375- .437
.062- .125
.125- .187
.187- .250
.250- .375
.375- .500
.500- .625
.375- .500
.500- .625
.625- .750
.750- .875
.375- .500
.500- .625
.625- .750
.750- .875
.875-1.000
1.000-1.125
Orange
Red
Black
Whi te
Blue
Green
Orange
Red
Whi te
B lue
Brown
Blue
Brown
Yel low
Purple
Blue
Brown
Yel low
Purple
Gray
Pink
ZS002CR
ZS003CR
ZS004CR
ZS006CR
ZS007CR
ZS101CR
ZS102CR
ZS103CR
ZS105CR
ZS108CR
ZS109CR
ZS208CR
ZS209CR
ZS210CR
ZS211CR
ZS308CR
ZS309CR
ZS310CR
ZS311CR
ZS312CR
ZS313CR
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1"
1"
1"
1"
1"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLORNUMBER* SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.125- .187
.187- .250
.250- .375
.375- .500
.500- .625
.375- .500
.500- .625
.625- .750
.750- .875
.625- .750
.750- .875
.875-1.000
Orange
Red
Whi te
Blue
Brown
Blue
Brown
Yel low
Purple
Yel low
Purple
Gray
ZN102CR
ZN103CR
ZN105CR
ZN108CR
ZN109CR
ZN208CR
ZN209CR
ZN210CR
ZN211CR
ZN310CR
ZN311CR
ZN312CR
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
CATALOG NPT CORD COLORNUMBER* SIZE RANGES CODE
ZS210CR ZN210CR
NPTSIZE
3/8"
1/2"
3/4"
1"
DIMENSIONSA B C D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
NPTSIZE
1/2"
3/4"
1"
DIMENSIONSA B C D
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
Z SERIES • F ITTINGSINCREASED SAFETY ALUMINUM CORD CONNECTORS
F78
FEATURES-SPECIFICATIONS
ApplicationsUse to secure and seal cords or cablesentering enclosures or raceways.
Z Series connectors are also suitablefor use in hazardous location applica-tions when installed according to NECArticles 501.10(b), Class I, Div. 2,(Suitable for use in Class I Zone 2applications) 502.10 and 503.10.Consult these articles for appropriateinstallation requirements.
Features• Aluminum construction resists
corrosion
• Neoprene grommet seals out oiland moisture
• Nylon retention ring ensures superi-or holding power
• Wide range of sizes and configura-tions
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
.062-.125
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
1.688-1.812
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
2.437-2.625
2.625-2.812
2.812-3.000
3.000-3.250
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
Green
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
–
–
–
–
–
–
–
ZS001-EX
ZS002-EX
ZS003-EX
ZS004-EX
ZS006-EX
ZS007-EX
ZS101-EX
ZS102-EX
ZS103-EX
ZS105-EX
ZS108-EX
ZS109-EX
ZS110-EX*
ZS111-EX*
ZS201-EX
ZS202-EX
ZS203-EX
ZS205-EX
ZS208-EX
ZS209-EX
ZS210-EX
ZS211-EX*
ZS308-EX
ZS309-EX
ZS310-EX
ZS311-EX
ZS312-EX
ZS313-EX*
ZS314-EX*
ZS315-EX*
ZS411-EX
ZS412-EX
ZS413-EX
ZS414-EX
ZS415-EX*
ZS511-EX
ZS512-EX
ZS513-EX
ZS514-EX
ZS515-EX
ZS516-EX
ZS517-EX*
ZS518-EX*
ZS520-EX*
ZS615-EX
ZS616-EX
ZS617-EX
ZS618-EX
ZS620-EX
ZS619-EX
ZS621-EX
ZS622-EX*
ZS623-EX*
ZS624-EX*
ZS719-EX
ZS721-EX
ZS722-EX
ZS723-EX
ZS724-EX
ZS725-EX*
ZS819-EX
ZS822-EX
ZS823-EX
ZS824-EX
ZS825-EX
ZS826-EX
ZS827-EX
ZS828-EX
ZS829-EX*
.99
.99
.99
.99
.99
.99
1.13
1.13
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
2.31
2.31
2.31
2.31
2.31
2.31
2.31
.90
.90
.90
.90
.90
.90
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
1.70
1.70
1.70
1.70
1.70
1.70
1.70
.425
.425
.425
.425
.425
.425
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.66
.66
.74
.74
.74
.74
.74
.453
.453
.453
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.255
1.255
1.255
1.255
1.255
2.31
2.31
2.31
2.31
2.31
3.00
3.00
3.00
3.00
3.25
3.25
3.25
3.25
3.25
4.06
4.06
4.06
4.06
4.06
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.87
4.87
4.87
4.87
1.70
1.70
1.70
1.70
1.70
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
.75
.75
.75
.75
.75
.75
.75
.75
.75
.80
.80
.80
.80
.80
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.30
1.30
1.30
1.30
1.30
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.50
1.50
1.50
1.50
1.92
1.92
1.92
1.92
1.92
1.94
1.94
1.94
1.94
1.94
2.34
2.34
2.34
2.34
2.34
2.34
2.54
2.54
2.54
2.54
2.54
3.00
3.00
3.00
3.00
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
3"
3"
3"
3"
3"
3"
3"
3"
3"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
Z C O R D C O N N E C T O R S — S T R A I G H T Z C O R D C O N N E C T O R S — S T R A I G H T
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
CATALOG NPT CORD DIMENSIONSNUMBER SIZE RANGES A B C D
CATALOG NPT CORD COLOR DIMENSIONSNUMBER SIZE RANGES CODE A B C D
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .ZS108-EX
Locknut
(See page F79)
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
AEx (Class I, Zone 1) Ex e II†Type 4**
Z SERIES • F ITTINGSINCREASED SAFETY ALUMINUM CORD CONNECTORS
F79
FEATURES-SPECIFICATIONS
F
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
O P T I O N A L L O C K N U T S A N D S E A L I N G W A S H E R S
NPTSIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBERSTEEL SEALINGLOCKNUTS1 WASHERS2KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with hexhead flats.
2Neoprene washers are mounted on steel reinforcing bands.
*Cable jacket may have to be stripped to pass
through connector body.
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.000-1.125
1.250-1.375
1.375-1.500
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Brown
Yellow
Purple
Gray
Pink
—
—
—
—
—
—
—
ZN102-EX
ZN103-EX
ZN105-EX
ZN108-EX
ZN109-EX*
ZN208-EX
ZN209-EX
ZN210-EX*
ZN211-EX*
ZN309-EX
ZN310-EX
ZN311-EX
ZN312-EX*
ZN313-EX*
ZN412-EX
ZN413-EX
ZN414-EX*
ZN415-EX*
ZN513-EX
ZN515-EX
ZN616-EX
1.56
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.08
2.08
2.08
2.08
2.08
3.18
3.18
3.18
3.18
3.18
3.18
3.50
2.30
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
3.20
3.20
3.20
3.20
3.20
4.30
4.30
4.30
4.30
4.30
4.30
5.50
.50
.50
.50
.50
.50
.562
.562
.562
.562
.703
.703
.703
.703
.703
.73
.73
.73
.73
.75
.75
.80
.546
.546
.546
.546
.546
.765
.765
.765
.765
1.00
1.00
1.00
1.00
1.00
1.26
1.26
1.26
1.26
1.50
1.50
1.92
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
CATALOG NPT CORD COLOR NUMBER SIZE RANGES CODE
DIMENSIONSA B C D
Z C O R D C O N N E C T O R S — 9 0 ºApplicationsUse to secure and seal cords orcables entering enclosures or raceways.
Z Series connectors are also suitablefor use in hazardous location appli-cations when installed according toNEC Articles 501.10(b), Class I, Div.2, (Suitable for use in Class I Zone 2applications) 502.10 and 503.10.Consult these articles for appropriateinstallation requirements.
Features• Aluminum construction resists
corrosion
• Neoprene grommet seals out oiland moisture
• Nylon retention ring ensures superior holding power
• Wide range of sizes and config-urations
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
ZN310-EX Locknut
Lis ted - F i le E22698
AEx (Class I, Zone 1) Ex e II†Type 4**
Cer t i f ied - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .
Z SERIES • F ITTINGSINCREASED SAFETY ALUMINUM CORD CONNECTOR WITH MESH GRIP
F80
FEATURES-SPECIFICATIONS
ApplicationsZ Series cord connector grips com-bine aluminum cord connectors withstainless steel mesh grips to providesuperior cord pull-out prevention inindoor and outdoor applications.These grips provide enclosure termi-nations where cords are subjected tomoisture or splashing water.
They are also suitable for use in haz-ardous location applications wheninstalled according to NEC Articles501.10(b), Class I, Div. 2, (Suitable foruse in Class I Zone 2 applications)502.10 and 503.10. Consult these arti-cles for appropriate installationrequirements.
Features• Aluminum fittings are strong,
durable and corrosion resistant
• Internal grommet provides liquid-tight seal
• Stainless steel mesh grips resistcorrosion, prevent cord pull-outand control arc-of-bend
Material/Finish• Copper-free aluminum
(less than 4/10 of 1%)
• Natural finish
• Stainless steel mesh grip
O P T I O N A L L O C K N U T S A N D S E A L I N G W A S H E R S
NPTSIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBERSTEEL SEALINGLOCKNUTS1 WASHERS2KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with hexhead flats.
2Neoprene washers are mounted on steel reinforcing bands.
.250-.312
.312-.375
.375-.437
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.00
1.00-1.125
Black
White
Blue
Red
White
Blue
Brown
Yellow
Purple
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS004-EX-MG
ZS006-EX-MG
ZS007-EX-MG
ZS103-EX-MG
ZS105-EX-MG
ZS108-EX-MG
ZS109-EX-MG
ZS110-EX-MG*
ZS111-EX-MG*
ZS203-EX-MG
ZS205-EX-MG
ZS208-EX-MG
ZS209-EX-MG
ZS210-EX-MG
ZS211-EX-MG*
ZS308-EX-MG
ZS309-EX-MG
ZS310-EX-MG
ZS311-EX-MG
ZS312-EX-MG*
ZS313-EX-MG*
.99
.99
.99
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
.90
.90
.90
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
.425
.425
.425
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
Z C O R D C O N N E C T O R S — S T R A I G H T
NPT CORD COLOR DIMENSIONSSIZE RANGES CODE A B C D
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
ZN103-EX-MG
ZN105-EX-MG
ZN108-EX-MG
ZN109-EX-MG*
ZN208-EX-MG
ZN209-EX-MG
ZN210-EX-MG*
ZN211-EX-MG*
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
.50
.50
.50
.50
.562
.562
.562
.562
.546
.546
.546
.546
.765
.765
.765
.765
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
NPT CORD COLORSIZE RANGES CODE
DIMENSIONSA B C D
Z C O R D C O N N E C T O R S — 9 0 º
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .LocknutZS310-EX-MG
ZN210-EX-MG
AEx (Class I, Zone 1) Ex e II†Type 4**
CATALOGNUMBER
CATALOGNUMBER
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
Z 90° D I M E N S I O N S
Z SERIES • F ITTINGSINCREASED SAFETY CORROSION RESISTANT NYLON CORD CONNECTORS
F81
FEATURES-SPECIFICATIONS
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .ZS210CR-EX ZN210CR-EX
O P T I O N A L L O C K N U T S
ApplicationsDurable nylon construction makesthese connectors perfectly suited tocorrosive environments.
Typical applications for nylon cordconnectors include food processingfacilities, chemical and sewage treat-ment plants and off-shore and dock-side installations.
Features• Nylon retention ring for increased
holding power
• Neoprene bushing seals againstmoisture
• Nylon connectors obtain approxi-mately the same cord retention val-ues with hand tightening that canbe produced only by wrench tight-ening of metal cord connectors
Material• Nylon CATALOG NPT
NUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS — STRAIGHT
.125- .187
.187- .250
.250- .312
.312- .375
.375- .437
.062- .125
.125- .187
.187- .250
.250- .375
.375- .500
.500- .625
.375- .500
.500- .625
.625- .750
.750- .875
.375- .500
.500- .625
.625- .750
.750- .875
.875-1.000
1.000-1.125
Orange
Red
Black
Whi te
Blue
Green
Orange
Red
Whi te
B lue
Brown
Blue
Brown
Yel low
Purple
Blue
Brown
Yel low
Purple
Gray
Pink
ZS002CR-EX
ZS003CR-EX
ZS004CR-EX
ZS006CR-EX
ZS007CR-EX
ZS101CR-EX
ZS102CR-EX
ZS103CR-EX
ZS105CR-EX
ZS108CR-EX
ZS109CR-EX
ZS208CR-EX
ZS209CR-EX
ZS210CR-EX
ZS211CR-EX
ZS308CR-EX
ZS309CR-EX
ZS310CR-EX
ZS311CR-EX
ZS312CR-EX
ZS313CR-EX
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1"
1"
1"
1"
1"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.125- .187
.187- .250
.250- .375
.375- .500
.500- .625
.375- .500
.500- .625
.625- .750
.750- .875
.625- .750
.750- .875
.875-1.000
Orange
Red
Whi te
Blue
Brown
Blue
Brown
Yel low
Purple
Yel low
Purple
Gray
ZN102CR-EX
ZN103CR-EX
ZN105CR-EX
ZN108CR-EX
ZN109CR-EX
ZN208CR-EX
ZN209CR-EX
ZN210CR-EX
ZN211CR-EX
ZN310CR-EX
ZN311CR-EX
ZN312CR-EX
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
AEx (Class I, Zone 1) Ex e II†Type 4**
NPTSIZE
3/8"
1/2"
3/4"
1"
DIMENSIONSA B C D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
Z S T R A I G H T D I M E N S I O N S
NPTSIZE
1/2"
3/4"
1"
DIMENSIONSA B C D
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
Z SERIES • F ITTINGSINCREASED SAFETY CORROSION RESISTANT NYLON CORD CONNECTORS
F82
FEATURES-SPECIFICATIONS
Lis ted - F i le E22698
Cer t i f i ed - F i le LR73478
See f i les for de ta i ls or ca l l K i l la rk .ZS308CR-EX-MG
O P T I O N A L L O C K N U T S
ApplicationsDurable nylon construction makesthese connectors perfectly suited tocorrosive environments.
Typical applications for nylon cordconnectors include food processingfacilities, chemical and sewage treat-ment plants and off-shore and dock-side installations.
Features• Nylon retention ring for increased
holding power
• Neoprene bushing seals againstmoisture
• Nylon connectors obtain approxi-mately the same cord retention val-ues with hand tightening that canbe produced only by wrench tight-ening of metal cord connectors
Material• Nylon
• Kevlar mesh grip
CATALOG NPTNUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS — STRAIGHT
.187- .250
.250- .312
.312- .375
.187- .250
.250- .375
.375- .500
.375- .500
.500- .625
.625- .750
.500- .625
.625- .750
.750- .875
.875-1.000
Red
Black
Whi te
Red
Whi te
B lue
Blue
Brown
Yel low
Brown
Yel low
Purple
Gray
ZS003CR-EX-MG
ZS004CR-EX-MG
ZS006CR-EX-MG
ZS103CR-EX-MG
ZS105CR-EX-MG
ZS108CR-EX-MG
ZS208CR-EX-MG
ZS209CR-EX-MG
ZS210CR-EX-MG
ZS309CR-EX-MG
ZS310CR-EX-MG
ZS311CR-EX-MG
ZS312CR-EX-MG
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1"
1"
1"
1"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.250- .375
.375- .500
.375- .500
.500- .625
.625- .750
.625- .750
.750- .875
Whi te
Blue
Blue
Brown
Yel low
Yel low
Purple
ZN105CR-EX-MG
ZN108CR-EX-MG
ZN208CR-EX-MG
ZN209CR-EX-MG
ZN210CR-EX-MG
ZN310CR-EX-MG
ZN311CR-EX-MG
1/2"
1/2"
3/4"
3/4"
3/4"
1"
1"
CATALOG NPT CORD COLORNUMBER SIZE RANGES CODE
AEx (Class I, Zone 1) Ex e II†Type 4**
NPTSIZE
3/8"
1/2"
3/4"
1"
DIMENSIONSA B C D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
Z S T R A I G H T D I M E N S I O N S
NPTSIZE
1/2"
3/4"
1"
DIMENSIONSA B C D
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
Z 90° D I M E N S I O N S
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
CTCA SERIES • F ITTINGSBARRIER TYPE FOR USE WITH UNARMORED CABLES
F83
FEATURES-SPECIFICATIONS
FApplications• Outdoor or Indoor use.
• For use with non armored cable,as permitted by the NEC.
Features• Provides a barrier seal between
the individual insulated conductors within the cable and prevents entryof the products of an explosioninto the cable.
• Assembly of the cable gland compresses and distributes thecompound evenly to effect a barri-er seal at the point of entry into theenclosure.
Class l, Div. 2, Groups A,B,C,DClass I, Zone 2, AEx d llCClass l, Zone 2, AEx e llClass II, Div. 2, Groups F,GClass IIIIP66NEMA 4X
CTCA
Max. Length
Entry Thread ‘E’ ‘B’‘D’
Compound
CTCAS050S
CTCAO050
CTCAA050L
CTCAB075
CTCAC100
CTCAC2125
CTCAD200
CTCAE250
CTCAF300
CTCAH350
1/2"
1/2"
1/2"-3/4"
3/4"-1"
1"-1 1/4"
1 1/4"-1 1/2"
2"-1 1/2"
2 1/2"-2"
3"-2 1/2"
3 1/2"
M20
M20
M20
M25
M32
M40
M50
M63
M75
M90
6
6
10
21
42
60
80
100
120
-
0.39"
0.39"
0.64"
0.93"
1.23"
1.59"
1.96"
2.55"
2.98"
3.12"
0.22"
0.37"
0.49"
0.66"
0.87"
1.10"
1.42"
1.81"
2.24"
3.07"
0.35"
0.35"
0.43"
0.64"
0.86"
1.04"
1.46"
1.88"
2.32"
2.79"
0.47"
0.63"
0.81"
1.02"
1.30"
1.61"
2.07"
2.57"
3.07"
3.52"
2.81"
2.81"
2.84"
2.95"
3.11"
3.26"
3.36"
3.56"
3.76"
3.54"
0.94"
0.94"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
4.18"
1.09"
1.09"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPTSTD./
OPTIONMETRIC
‘E’MAX.INNER
SHEATH
‘D’MAX.OVER
CORES MIN. MAX.
‘G’
ACROSSFLATS
ACROSSCORNERS
ENTRY THREADSIZE
OUTER JACKET ‘B’
HEXAGONDIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZEREF.
Os
O
A
B
C
C2
D
E
F
H
• Provides an outer deluge seal toprevent moisture ingress to thecable armor and enclosure.Deluge seal is colored red to indi-cate Hazardous Area product.
• Provides a cable retention and lowsmoke and fume, zero halogenseal onto the cables outer sheath.
MAX.NO. OFCORES
INNER SHEATH/ CORES
Materials• Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range• -50°C to +60°C
CMCA SERIES • F ITTINGSALUMINUM CABLE CONNECTORS
F84
FEATURES-SPECIFICATIONS
Applications
Designed for use with jacketed inter-locked and continuously welded/corrugated armor cable where it isessential to provide positive ground-ing of cable armor and a NEMA 3, 4,4X connection. e.g. TEC
®
or MC typecable. Use outdoors or indoors.
Features
• Provides 360° armor groundingwhich is fully inspectable.
• Grounding Device remains in con-tact with cable when disassembedfor inspection.
• Provides cable retention and a lowsmoke and fume, zero halogenseal onto the cables outer sheath.
• Provides an outer deluge seal toprevent moisture ingress to thecable armor and enclosure.
Materials• Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range• -50°C to +60°C
NEMA 4X
Sealing Backnut
Deluge Seal
Inspectable Armor
Grounding Device
CMCAA050
CMCAB075
CMCAC100
CMCAC2125
CMCAD200
CMCAE250
CMCAF300
CMCAH350
1/2"-3/4"
3/4"-1"
1"-1 1/4"
1 1/4"-1 1/2"
2"-1 1/2"
2 1/2"-2"
3"-2 1/2"
3 1/2"
M20
M25
M32
M40
M50
M63
M75
M90
0.49"
0.66"
0.87"
1.10"
1.42"
1.81"
2.24"
3.18"
0.41"
0.49"
0.85"
1.17"
1.37"
1.76"
2.29"
2.92"
0.80"
1.02"
1.29"
1.61"
2.07"
2.57"
3.07"
3.52"
3.35"
3.61"
3.90"
4.01"
4.94"
5.15"
5.17"
5.17"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
4.18"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPTSTD./
OPTIONMETRIC
MIN. MAX.
ARMOR SHEATH‘A’
MIN. MAX.
MAX.LENGTH
ACROSSFLATS
ACROSSCORNERS
ENTRY THREADSIZE INNER SHEATH/
CORES OUTER JACKET ‘B’
HEXAGONDIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZEREF.
A
B
C
C2
D
E
F
H
CMCA
Max. Length
Entry Thread ‘A’ ‘B’
Class I, Div. 2†, Groups A, B, C, D Class l, Zone 1, AEx e ll Class II, Div. 1 & 2, Groups E, F, GClass IIIClass I, Zones 1 & 2†Suitable for wet locationsTypes 3, 4, 4XIP66
0.64"
0.93"
1.23"
1.59"
1.96"
2.55"
2.98"
3.47"
Cable armor diameter and cable jacket diameter refer to the dimensions across the crest - all dimensions in inches.
† Where explosion proof/flameproof enclosures are being used the CMCA must be installed in conjunction with an approved sealing
fitting. In Division 2 areas the CMCA can be fitted directly to an enclosure which has no source of ignition.
ConstructionDetails
CMCXA SERIES • F ITTINGSALUMINUM CABLE CONNECTORS
F85
FEATURES-SPECIFICATIONS
F
CMCXA
Class I, Div. 1 & 2, Groups A, B, C, DClass l, Zone 1 AEx d llCClass l, Zone 1 AEx e ll Class II, Div. 1 & 2, Groups E, F, GClass IIISuitable for wet locationsTypes 3, 4, 4XIP66
Applications
Designed for use with jacketed inter-locked and continuously welded/corrugated armor cable where it isnecessary to provide a complete gasblock/explosion proof seal to thecable, plus a NEMA 3, 4, 4x connec-tion. Example: TEC or MC-HL typecable. Use outdoors or indoors.
Features
• Provides 360° armor grounding
which is fully inspectable.
• Grounding Device remains in con-
tact with cable when disassembed
for inspection.
• Provides a barrier seal between the
individual insulated cores within
the cable and prevents entry of
the products of an explosion into
the cable.
• Assembly of the cable gland com-
presses and distributes the compound
evenly to create a barrier seal at the
point of entry into the enclosure.
• Provides cable retention and a low
smoke and fume, zero halogen seal
onto the cables outer sheath.
• Provides an outer deluge seal to
prevent moisture ingress to the
cable armor and enclosure. Deluge
seal is colored red to indicate
Hazardous Area product.
Materials• Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range• -50°C to +60°C
NEMA 4X
Sealing Backnut
Deluge Seal
Inspectable Armor
Grounding Device
ConstructionDetails
Max. Length
Entry Thread ‘E’ ‘B’‘D’
Compound
CMCXAA050
CMCXAB075
CMCXAC100
CMCXAC2125
CMCXAD200
CMCXAE250
CMCXAF300
CMCXAH350
1/2"-3/4"
3/4"-1"
1"-1 1/4"
1 1/4"-1 1/2"
2"-1 1/2"
2 1/2"-2"
3"-2 1/2"
3 1/2"
M20
M25
M32
M40
M50
M63
M75
M90
0.43"
0.64"
0.86"
1.04"
1.46"
1.88"
2.32"
2.79"
10
21
42
60
80
100
120
120
0.49"
0.66"
0.87"
1.10"
1.42"
1.81"
2.24"
3.18"
0.41"
0.49"
0.85"
1.17"
1.37"
1.76"
2.29"
2.92"
0.64"
0.93"
1.23"
1.59"
1.96"
2.55"
2.98"
3.47"
0.80"
1.02"
1.29"
1.61"
2.07"
2.57"
3.07"
3.52"
2.95"
3.20"
3.54"
3.73"
5.08"
5.11"
4.88"
5.02"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
4.18"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPTSTD./
OPTIONMETRIC
MIN. MAX.
ARMOR SHEATH‘E’
‘D’MAX.OVER
CORES
MAX.NO. OFCORES
MIN. MAX.
MAX.LENGTH
ACROSSFLATS
ACROSSCORNERS
ENTRY THREADSIZE
INNER SHEATH/ CORES OUTER JACKET ‘B’
HEXAGONDIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZEREF.
A
B
C
C2
D
E
F
H
Sealing chamber
SWZ/LNZ/ZHLN SERIES • F ITTINGSSEALING WASHERS AND LOCKNUTS
F86
FEATURES-SPECIFICATIONS
Increased Safety LocknutsUsed to secure conduit hubs or similiarproducts entering an enclosure, thesezink locknuts have an increased safetyterminal for grounding purposes.
Z H L N Z I N C L O C K N U T S
SIZE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
CATALOG NUMBER
ZHLN-170
ZHLN-270
ZHLN-370
ZHLN-470
ZHLN-570
ZHLN-670
ZHLN-770
ZHLN-870
ZHLN-970
NPT DIMENSIONSDIAMETER
A1.5"
1 .7"
2 .0"
2 .4"
2 .8"
3 .3"
3 .7"
4 .4"
5 .0"
HEIGHTB
11/16"
3/4"
3/4"
53/64"
31/32"
31/32"
1-1/4"
1-1/4"
1-5/16"
LNZ10-050NPTSWZ60-050NPT ZHLN-170
Sealing (IP) WashersSealing washers are commonlyused with cable glands or similarfittings entering an enclosure.While these products are notthreaded, they are available withclearance holes to accommodate awide range of threadforms includ-ing ISO (metric), NPT, PG, BSP,and ET. Sealing washers are avail-able in nylon. The most commoncombinations are listed. For option-al combinations, contact Killark.
S W Z N Y L O N W A S H E R S
NPT
SIZE CATALOG NUMBER
1/2" SWZ60-050NPT
3/4" SWZ60-075NPT
1" SWZ60-100NPT
1-1/4" SWZ60-125NPT
1-1/2" SWZ60-150NPT
2" SWZ60-200NPT
2-1/2" SWZ60-250NPT
3" SWZ60-300NPT
3-1/2" SWZ60-350NPT
LocknutsThese fittings are commonly usedto secure cable glands or similarproducts entering an enclosure.These products are available in awide range of threadforms includ-ing ISO (metric), NPT, PG,Imperial, BSPP, BSPT, NPS, ET,other UK and European, Japaneseand CIS. These products areavailable in brass (standard) orNylon 6, or can be speciallyordered in 316 stainless steel,steel and aluminum which can beplated in nickel, zinc, cadmiumand chromium (Plating not possi-ble with nylon). The most commoncombinations are listed. Foroptional combinations, contactKillark.
L N Z B R A S S L O C K N U T S
NPT
SIZE CATALOGNUMBER
1/2" LNZ10-050NPT
3/4" LNZ10-075NPT
1" LNZ10-100NPT
1-1/4" LNZ10-125NPT
1-1/2" LNZ10-150NPT
2" LNZ10-200NPT
2-1/2" LNZ10-250NPT
3" LNZ10-300NPT
PCC/ECC/RACC SERIES • F ITTINGSCONDUIT CLAMPS
F87
FEATURES-SPECIFICATIONS
F
PARALLEL TYPE EDGE TYPE RIGHT ANGLE TYPE Lis ted - F i le E213669
Applications• Designed to secure rigid metal conduit, IMC
or EMT across, parallel or prependicular tochannel, beam and angle supports.
Features• Three styles meet every installation need
• Heavy duty U-bolts, hex bolts and hex nuts
• Capable of supporting heavy loads
Material/Finish
• Malleable iron (hot dipped galvanized) with
steel U-bolts and nuts (mechanically
galvanized).
CATALOGNUMBER
P C C PA R A L L E L T Y P E C L A M P S
2-7/8"(73)
3-1/16"(78)
3-1/4"(83)
3-5/8"(92)
3-7/8"(98)
4-5/8"(117)
5-1/4"(133)
5-1/8"(149)
6-5/16"(160)
6-13/16"(173)
1-7/16"(36)
1-11/16"(43)
2"(51)
2-1/8"(53)
2-3/16"(56)
2-7/8"(73)
3-1/4"(83)
3-1/8"(98)
4-5/16"(110)
4-13/16"(122)
PCC050
PCC075
PCC100
PCC125
PCC150
PCC200
PCC250
PCC300
PCC350
PCC400
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CONDUITSIZE
A B
RACC TypeECC Type
PCC Type
Dimensions
CATALOGNUMBER
R A C C R I G H T A N G L E T Y P E C L A M P S
1"(25)
1-1/8"(29)
1-3/8"(35)
1-3/4"(44)
2"(51)
2-1/2"(64)
2-1/2"(64)
3-5/8"(92)
4-1/16"(103)
4-11/16"(119)
1-1/4"(32)
1-3/8"(35)
1-5/8"(41)
2"(51)
2-3/8"(60)
2-1/2"(64)
3"(76)
3-7/8"(98)
4-9/16"(116)
5-1/16"(129)
RACC050
RACC075
RACC100
RACC125
RACC150
RACC200
RACC250
RACC300
RACC350
RACC400
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CONDUITSIZE
A B
2-1/2"(64)
2-13/16"(72)
3-1/16"(78)
3-3/16"(81)
3-1/2"(89)
4-1/2"(114)
3-1/4"(83)
5-3/8"(137)
5-7/8"(149)
6-11/16"(170)
C
1-13/16"(46)
1-13/16"(46)
1-13/16"(46)
1-13/16"(46)
1-13/16"(46)
2-5/8"(67)
4-7/8"(124)
2-5/8"(67)
2-5/8"(67)
2-5/8"(67)
D
2-1/16"(52)
2-1/4"(57)
2-9/16"(65)
2-7/8"(73)
3-1/4"(83)
4-1/16"(103)
2-5/8"(67)
5-1/8"(130)
5-5/8"(143)
6-1/8"(156)
E
CATALOGNUMBER
E C C E D G E T Y P E C L A M P S
2-13/16"(71)
2-15/16"(75)
3-1/16"(78)
3-1/16"(78)
3-15/16"(100)
4-1/2"(114)
5-1/8"(130)
5-3/4"(146)
2-1/8"(54)
2-3/8"(60)
2-5/8"(67)
3-1/16"(78)
3-1/4"(83)
4-1/16"(103)
4-5/8"(117)
5-1/4"(133)
ECC050
ECC075
ECC100
ECC125
ECC150
ECC200
ECC250
ECC300
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CONDUITSIZE
A B
NEW!
FITTINGSNOTES
F88
Top Related