Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC INFORMATION
FactoryTalk View Site EditionVZ11 - Arquitetando um sistema distribuído
Paul HaikalInstructional Developer2014
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 2
Agenda
FactoryTalk View Network Station
Criando as Bases
Visão Geral do sistemaFactoryTalk View SE , Limites dos Sistema e Redundância
Lab Exercício – Projetar um Sistema Distribuído
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk View Site Edition Design & Deploy – Section 1Laying the Foundations
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Considerations
4
Domains, Workgroups, and Operating System Considerations TF08 - Operating Systems Considerations
Remote Desktop Services VZ10 - Extending FactoryTalk View SE with Microsoft's Remote Desktop
Services
Ethernet Network NW02 - Applying EtherNet/IP in Real-Time Applications NW14 - Wireless Design Considerations for Industrial Applications
Virtualization TF02 - Virtualization in Manufacturing Industries
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk View Site Edition Design & Deploy – Section 2System Overview
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Visão Geral FactoryTalk View
6
FactoryTalk View SE DistribbuídoFactoryTalk View SE Estação
Clients
Data Servers
View SEServers
View Studio Development
Station
FactoryTalkDirectory
Server
Ambiente de desenvolvimento comum
Ambiente de desenvolvimento comum
Escalável de uma única estação até uma arquitetura cliente / servidor distribuído
Escalável de uma única estação até uma arquitetura cliente / servidor distribuído
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
7
CLX
CLX High Availability
StudioEnterprise
FT Diretório
SE Cliente Servidor
DadosHMI
Servidor
ServidorAlarme
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FACTORYTALK DIRETÓRIO2.1
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Visão Geral da Plataforma de ServiçosFactoryTalk
9
• Common software license management for all FactoryTalk products
• Common software license management for all FactoryTalk products
Ativação
• Common address lookup of resources that are shared among FactoryTalk enabled products
• Common address lookup of resources that are shared among FactoryTalk enabled products
Diretório
• Common security authority for all FactoryTalk components in the system
• Common security authority for all FactoryTalk components in the system
Securança
• Common diagnostic messaging sub-system across all FactoryTalk products
• Common diagnostic messaging sub-system across all FactoryTalk products
Diagnóstico
• Comprehensive record of any changes made to the manufacturing system
• Comprehensive record of any changes made to the manufacturing system
Auditoria
• Enterprise-wide access to real-time manufacturing data
• Enterprise-wide access to real-time manufacturing data
Dados emtempo real
• Enterprise-wide notification to real-time alarms and events that require action
• Enterprise-wide notification to real-time alarms and events that require action
Alarmes e Eventos
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
10
Sem Ativação Ùnico dietório para
todo Sistema Directory is cached
at every component Servidor OS
CLX
CLX High Availability
StudioEnterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Why a Stand-alone FT Directory Host?
11
System Start-up Recommended that the FTD is the first FactoryTalk component to
start, and the last to stop.
Patching/Upgrading Dedicated host results in minimum system downtime with fewer
components to patch and less affect upon reboot.
Redundancy While redundant servers (e.g., HMI, Data, Alarm) can function properly
in the absence of the FTD, the lowest risk scenario is FTD uptime.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. 12
Instalação do FactoryTalk Diretório
Stand‐alone FactoryTalk Directory Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Detalhes da Instalação
13
When selecting Stand-alone FactoryTalk Directory Server, the following components are installed by default;
FactoryTalk Service Platform FactoryTalk Activation Manager
RequiredOptional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
CLx CLx CLxCLx
PLC
SLCFlex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
Diretório FactoryTalk
14
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
View SE CLIENTES2.2
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
Activation Required Up to 50 Clients Workstation OS
CLX
CLX High Availability
StudioEnterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
16
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Instalação do SE Cliente
17
Site Edition Client
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Installation Details
18
When selecting Site Edition Client, the following components are installed by default;
FactoryTalk Service Platform FactoryTalk Activation Manager FT View Site Edition Client FactoryTalk Alarms and Events
RequiredOptional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
HMI Clientes
19
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
SE HMI SERVIDORES2.3
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
HMI Server Considerations
21
Maximum number of SE HMI servers that can be hosted on a single computer is 1.
HMI servers supported in an application is 10 for non-redundant and redundant servers.
Redundant servers are limited to 5 in versions earlier than v7.0 of View SE.
How do licenses get served? From 1st to last, as projects load in the application FactoryTalk View HMI Servers look for lowest key first This prevents the 25 display server from using a 100 display key
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
HMI Server Licensing Example
100display server
100display server
25 display server
Operator ClientsFactoryTalk Operator Clients
DomainController
Data Server
250 display server license ???
Data Area
Supervisor /Management Clients
FactoryTalk View Studio
22
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
Activation Required Up to 10 Servers High Availability Server OS
CLX
CLX High Availability
StudioEnterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
23
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Quando Utilizar HMI ServidoresMultiplos
24
Load balancing Application server limits reached. Large number of clients for single application.
Logical or Physical areas Ability to take down one HMI server for maintenance without affecting entire
system.
Expansion Grow an application by adding a new line, duplicate existing Line 1 HMI server
into new Line 2 HMI server.
Security Creating multiple servers allows security configuration at an area level.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Instalação SE HMI Server
25
Site Edition Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Installation Details
26
When selecting Site Edition Server, the following components are installed by default;
FactoryTalk Service Platform FactoryTalk Activation Manager FT View Site Edition Server FT View Site Edition Client FactoryTalk Alarms and Events RSLinx Enterprise RSLinx Classic Required
Optional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
HMI Servers
27
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
SE Server• (1) HMI Server
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
DATA SERVERS2.4
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk Data Server Options
RSLinx Enterprise – **Preferred** Live Data Server for FactoryTalk View SE and other FactoryTalk applications (FactoryTalk
Transaction Manager, FactoryTalk Historian, FactoryTalk Metrics) Optimized performance via TCP/IP, not DCOM Offline browsing of Logix based controller project Preferred Data Server for ALL Rockwell Automation controllers
RSLinx Classic Alias Topic Functionality Complex communication routing. Protocol changing (ex. Ethernet to DH+) Offline browsing of PLC/SLC RSLogix files
3rd Party OPC Server To communicate with non-AB controllers KepWare Kepserver Enterprise ships with FactoryTalk View SE
29
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes No Activation** Up to 10 Servers High Availability Server OS 100,000 tags per server
CLX
CLX High Availability
StudioEnterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
30
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Recommended maximum of 100,000 tags/sec on a single RSLinx Enterprise data server.
Example system: 1 FactoryTalk View SE HMI Server/redundant 12 FactoryTalk View SE Clients 20 controllers w/5,000 tags/sec on scan
Maximum number of tags/sec are determined by a number of variables: Types of servers in application (e.g., View SE, Historian SE, etc…) Number of servers in application Number of HMI clients in application
Data ServersRSLinx Enterprise Sizing Considerations
31
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Data ServersRSLinx Enterprise Sizing Considerations
Recommended maximum of 100,000 tags/sec on a single RSLinxEnterprise data server.
Recommended maximum of tag references should not exceed 2,000,000. Tag references can include tag server, datalog, derived tags, event tags,
tags on client, etc…
Worst case scenario to calculate tag references Tag References =A(6x)+Bx
A is # of FTView SE HMI servers x is # of total tags B is # of FT clients, (Historian, View client, FTGW )
System from previous slide 1(6*100k)+12*100k=1,800,000 tag references
32
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
RSLinx Enterprise Data Server Install
33
Stand‐alone RSLinx Enterprise Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Detalhes daInstalação
34
When selecting Stand-alone RSLinx Enterprise Server, the following components are installed by default;
FactoryTalk Service Platform FactoryTalk Activation Manager FactoryTalk Alarms and Events RSLinx Enterprise RSLinx Classic
RequiredOptional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Servidores de Dados
35
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
SE Server• (1) HMI ServerData Server• (1) RSLinx Enterprise
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Servidores de Alarme2.4
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Alarming
37
HMI/Legacy Alarm configuration and status is located in the HMI server. Uses legacy alarm objects (Banner, Summary.)
Tag-Based Alarm configuration and status is located in the FactoryTalk Alarm server. Uses new alarm objects (Banner, Summary, etc.) Can use RSLinx Enterprise, Classic, or 3rd party OPC
Preferred alarming method for legacy and 3rd party devices
Device-Based Alarm configuration and status is located in the Logix 5000 device. Uses new alarm objects (Banner, Summary, etc.) Utilizes RSLinx Enterprise for alarm communications
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk Alarms and Events
38
• Alarm instructions available in the Logix family of controllers.
• The controller detects alarm conditions and triggers alarm events
• The FactoryTalk Alarms and Events server captures all of the controller events and sends notification to connected clients
• Information is displayed in the Alarm Management components on the clients
• Alarm instructions available in the Logix family of controllers.
• The controller detects alarm conditions and triggers alarm events
• The FactoryTalk Alarms and Events server captures all of the controller events and sends notification to connected clients
• Information is displayed in the Alarm Management components on the clients
Device-Based Alarms
• Software-based alarm servers poll data tags for alarm conditions.
• The Alarm server detects alarm conditions and triggers alarm events
• The FactoryTalk Alarms and Events server captures all of the controller events and sends notification to connected clients
• Information is displayed in the Alarm Management components on the clients
• Supports PLC-5, SLC 500, or any third-party device through OPC-DA
• Software-based alarm servers poll data tags for alarm conditions.
• The Alarm server detects alarm conditions and triggers alarm events
• The FactoryTalk Alarms and Events server captures all of the controller events and sends notification to connected clients
• Information is displayed in the Alarm Management components on the clients
• Supports PLC-5, SLC 500, or any third-party device through OPC-DA
Tag-Based Alarms
Two different types of alarm sources:
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Controller specificationsSpecification Value
Number of “subscribers” (alarm servers) per controller 16
Controller memory used for buffering by each subscriber 100k
Typical number of alarm state transitions per subscriber 1000
Recommended maximum number of alarms per controller 2000
Approximate controller memory used for each alarm 1k
Supported languages for alarm messages All languages supported by FactoryTalk View.
v16.03 - v20 firmware
FactoryTalk A&E - Device-Based Alarms
39
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk A&E - View SE 7.0
A maximum of 10 FactoryTalk A&E Device and Tag Alarm Servers per FactoryTalk application This is not enforced in the software.
A maximum of 100,000 FactoryTalk A&E alarm points per FactoryTalk application. This is a mix of either device alarms or tag based alarms
A maximum of 50 Clients simultaneously connected to the application.
40
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
41
No Activation Up to 10 Servers High Availability Server OS Max – 10,000 alarms per server
CLX
CLX High Availability
Studio Enterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Alarms and Events Server Installation
42
Stand‐alone RSLinx Enterprise Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Detalhes da Instalação
43
When selecting Stand-alone RSLinx Enterprise Server, the following components are installed by default;
FactoryTalk Service Platform FactoryTalk Activation Manager FactoryTalk Alarms and Events RSLinx Enterprise RSLinx Classic
RequiredOptional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Servidores de Alarme
44
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
SE Server• (1) HMI ServerData Server• (1) RSLinx EnterpriseAlarm Server• (1) A&E Tag-based Server
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
VIEW STUDIO ENTERPRISE2.6
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Diagrama de Blocos dos Componentes
46
Activation Required Multi-user development Up to 5 simultaneous
development stations Workstation OS
CLX
CLX High Availability
StudioEnterprise
FT Directory
SE Client Data
ServerHMI
Server
Alarm Server
DNS AD
DHCP
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Studio Enterprise Installation
47
Studio Enterprise
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Installation Details
48
When selecting View Studio Enterprise, the following components are installed by default; FactoryTalk Service Platform FactoryTalk Activation Manager FT View Studio Enterprise FT View Site Edition Server FT View Site Edition Client FactoryTalk Alarms and Events RSLinx Enterprise RSLinx Classic Faceplates and Add-on Instructions Required
Optional; Included by defaultOptional; Not included by default
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Application Server• (1) HMI Server • (1) Data Servers
• RSLinx Enterprise w/Alarms and Events
• (1) Tag-based Alarm Server
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
View Studio Enterprise
49
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•W2K8 Server O/S•DNS/DHCP/WINS
Engineering Workstation• RSLogix 5/500/5000• RSLinx Classic• View Studio
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Engineering Workstation• RSLogix 5/500/5000• RSLinx Classic• View Studio
HMI Server• (1) HMI Server • (1) Data Servers
• RSLinx Enterprise w/Alarms and Events
• (1) Tag-based Alarm Server
Secondary Server• (1) HMI Server • (1) Data Servers
• RSLinx Enterprise w/Alarms and Events
• (1) Tag-based Alarm Server
Primary Server• (1) HMI Server • (1) Data Servers
• RSLinx Enterprise w/Alarms and Events
• (1) Tag-based Alarm Server
RedundantPair
FactoryTalk Directory Server• FTD• FactoryTalk Activation Server
Exemplo de Sistema
51
CLx CLx CLxCLx
PLCSLC
Flex
PLCSLC
Flex
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Managed Ethernet Switch for Control System Network (CSN) – HMI/Ctrl Communications
Internet
Firewall
Domain Controllers•For the Ctl Sys Domain•W2K8 Server O/S•DNS/DHCP/WINS
5 Clients
FT View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk View Site Edition Design & Deploy – Section 3Design a View SE Application Exercise
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design a View SE Distributed System
53
Design a FactoryTalk View SE Network Distributed system for a customer with the following criteria.
The plant is divided into 2 areas. The first consists of Small Production Line 1 and Production Line 2.
This area of the plant runs from 8 AM to 5 PM and power is turned off outside these ours to conserve energy.
There is a need for 240 screens and about 5000 alarms. Customer is requesting redundancy for their alarms in this area.
The second is made up of Production Line 3. This area runs 24/7. In this area, there is a need for 251 screens and 10,000 alarms. Customer is requesting full redundancy (HMI , Alarms, and Data Servers) for this
area. There is a need for 1 Engineering workstation, 10 Read/Write thick clients Some displays have to be made available to the plant manager laptop without
installing any Rockwell Software on it. The customer has provided 5 servers, 1 engineering workstation and 10 operator
workstations.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design a View SE Distributed System
54
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design a View SE Distributed System
55
View Studio Enterprise RSLogix 5000 / Studio 5000 RSLogix 5 RSLinx Classic Lite
10 View SE Clients
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design a View SE Distributed System
56
FTD Located in
Area2 that runs 24x7
Area2 Primary
HMI (unlimited)
Alarm Server
Data Server
Area1 Primary
HMI (250) Alarm
Server Data
Server
Area1 Secondary
Alarm Server
Data Server
Area2 Secondary
HMI (unlimited)
Alarm Server
Data Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design a View SE Distributed System
57
FTD Located in
Area2 that runs 24x7
Area2 Primary
HMI (unlimited)
Alarm Server
Data Server
Area1 Secondary
Alarm Server
Data Server
Area2 Secondary
HMI (unlimited)
Alarm Server
Data Server
Area1 Primary
Alarm Server
Data Server
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
VIEW SE APPLICATION TYPES2.7
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Multiple SE ClientsMultiple HMI ServersMultiple Data ServersMultiple A&E ServersCentralized SecurityMultiple activationsIIS RequiredHMI Server RedundancyData Server RedundancyA&E Server RedundancyRemote Studio for Online EditsInformation Software integration
1 SE Client + 1 HMI Sever on 1 PC+1 A&E Server +1 RSLinx EnterpriseMultiple OPC Data ServersApplication Manager (apa) for backupIsolated SecurityUses only Station activationIIS Not RequiredNo RedundancyThey all Support FT ViewPointRemote Studio for Online EditsTo be supported in Version 8.0
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
www.rsteched.com
Follow RSTechED on Facebook & Twitter.Connect with us on LinkedIn.
PUBLIC INFORMATION
THANK YOU
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
We care what you think!
On the mobile app:1. Locate session using
Schedule or Agenda Builder2. Click on the thumbs up icon on
the lower right corner of the session detail
3. Complete survey4. Click the Submit Form button
61
Please take a couple minutes to complete a quick session survey to tell us how we’re doing.
2
3
4
1
Thank you!!
Top Related