pmeasuring.com
FacilityPro® ProcessorsData Processing and System Control
Without measurement there is no control
B E N E F I T S• Designed specifically for pharmaceutical
environmental monitoring
• Integration and control of viable and nonviable sampling
• High data integrity
• Ultimate efficiency and reduced error
• Simple installation and validation
• Flexible integration
A P P L I C AT I O N SMonitoring of critical environments including:
• Filling lines
• Isolators and RABS
• Blow-Fill-Seal
• Lyophilizer processes and transfer carts
• Biosafety cabinets and flow hoods
• General cleanroom and facility monitoring
Viable/Nonviable/Environmental Monitoring
The FacilityPro® Processor provides the central hub for an environmental monitoring system. The Processor communicates with cleanroom sensors, including particle and microbial monitors, while buffering data and checking tolerances for alarm activation.
Industrial Automation Architecture
As a key component of industrial automation architecture, this embedded system offers high reliability as it controls samples and communicates with central software.
Three Versions
FacilityPro Processors are available in three versions, with varying features to support a range of system designs and applications:
• FacilityPro 5010
• FacilityPro 3000
• FacilityPro 1000
All three FacilityPro Processors are compatible with either the FacilityPro SCADA server software or the FacilityPro SMART server module. The FacilityPro 1000 Processor is also suitable for OEM applications, providing an integration path between Particle Measuring Systems sensors and third-party software platforms.
FacilityPro 3000
FacilityPro 1000
FacilityPro 5010
FacilityPro® ProcessorsData Processing and System Control
Display 6.5-in TFT LCD with resistive touchscreen
Processor AMD Geode LX800 (500 MHz)
Dimensions (l, w, h) 13.5 x 19.0 x 8.75 in (34.3 x 48.3 x 22.3 cm), 5U height
Weight 34.5 lb (15.7 kg)
Power 100 – 240 VAC, 50 – 60 Hz, 600 W
Operating Environment Temperature: 39 – 104 °F (4 – 40 °C); non-condensing
Processor Module
Dimensions (l, w, h) 8 x 19 x 7.0 in (20 x 48.3 x 17.8 cm), 4U height
Weight 26.4 lb (12 kg)
Power 100 – 240 VAC, 50 – 60 Hz, 240 W
Operating Environment Temperature: 39 – 104 °F (4 – 40 °C); non-condensing
Sensor Module
Dimensions (l, w, h) 12.0 x 19.0 x 7.0 in (30.5 x 48.3 x 17.8 cm), 4U height
Weight 31.4 lb (14.2 kg)
Power 100 – 240 VAC, 50 – 60 Hz, 240 W
Operating Environment Temperature: 39 – 104 °F (4 – 40 °C); non-condensing
Inputs/Outputs 16 relay or digital outputs (configurable)8 digital inputs24 analog inputs; 0 – 10 VDC or 4-20mA (optional)
Input/Output Module
Dimensions (l, w, h) 14.0 x 19.0 x 5.25 in (35.6 x 48.3 x 13.3 cm), 3U height
Weight 22.3 lb (10.1 kg)
Power 460–480VAC 3-ph, 50–60Hz and 100-240VAC, 50-60Hz
Operating Environment Temperature: 39 – 104 °F (4 – 40 °C); non-condensing
Power Module
FacilityPro 5010A fully-integrated solution for system control. Modules housed in a standard 19-inch rack.
FacilityPro® ProcessorsData Processing and System Control
Processor Intel Atom N455 (1.66 GHz)
Dimensions (l, w, h) 6.2 x 19.0 x 13.2 in (15.8 x 48.3 x 33.5 cm)
Weight 27.5 lb (12.5 kg)
Power 100 – 240 VAC, 50 – 60 Hz, 350 W
Inputs/Outputs 16 relay or digital outputs (configurable)8 digital inputs8 analog inputs, 0 – 10 VDC or 4-20mA (optional)
FacilityPro 3000A reliable data and I/O processor designed specifically for smaller systems.
Processor Intel Atom N455 (1.66 GHz)
Dimensions (l, w, h) 5.7 x 9.0 x 2.6 in (14.5 x 23.0 x 6.5 cm)
Weight 2.5 lb (1.14 kg)
Power 120 VDC, 1.5 A
Inputs/Outputs None (via ENODE® interface)
FacilityPro 1000Data processor with no built-in I/O, designed to provide a reliable Ethernet interface to viable and nonviable sensors and to upgrade existing ENODE-based systems.
FacilityPro® ProcessorsData Processing and System Control
2016.07
HEADQUARTERS 5475 Airport BlvdBoulder, Colorado 80301 USAT: +1 303 443 7100, +1 800 238 1801
Instrument Service & SupportT: +1 800 557 6363Customer Response CenterT: +1 877 475 3317E: [email protected]
GLOBAL OFFICES BRAZILT: +55 11 5188 8227 E: [email protected]
CHINA T: +86 21 6113 3600E: [email protected]
FRANCET: +33 (0)6 82 99 17 98E: [email protected]
GERMANY T: +49 6151 6671 632E: [email protected]
ITALY T: +39 06 9053 0130 E: [email protected]
JAPAN T: +81 3 5298 8175 E: [email protected]
KOREA T: +82 31 286 5790 E: [email protected]
MEXICO T: +52 55 2271 5106 E: [email protected]
NORDIC T: +45 707 028 55 E: [email protected]
PUERTO RICOT: +1 787 718 9096 E: [email protected]
SINGAPORET: +65 6496 0330 E: [email protected]
SWITZERLANDT: +41 71 987 01 01E: [email protected]
TAIWANT: 886-3-5525300 Ext: 301E: [email protected]
UNITED KINGDOMT: +44 1684 581 000 E: [email protected]
ENODE®and FacilityPro® are registered trademarks of Particle Measuring Systems, Inc.Windows® is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.Particle Measuring Systems, Inc. reserves the right to change specifications without notice.
© 2016 Particle Measuring Systems, Inc. All rights reserved.
Feature Comparison
FacilityPro 1000 FacilityPro 3000 FacilityPro 5010Particle & microbial
points per Processor 8, 16, 32 (groups of 8) 16 (8 particle, 8 microbial) 64 (groups of 8)
Digital ouputs (selectable relay or 24
VDC)- 16 up to 64 in processor
(optional I/O module)
Digital inputs - 8 up to 32 in processor (optional I/O module)
Analog inputs (optional) - 8 up to 24 in processor
(optional I/O module)
ENODE support y - -
Cubic meter algorithms y y y
Tolerance checking y y y
Recipe-driven sampling y y y
Data buffer y y y
Real-time microbial monitoring - - y
Vacuum and air flow control - - y
Microbial monitoring with central vacuum - - y
- : not supported y : supported
pmeasuring.com
FacilityPro® SoftwareData Management, Reporting, and Automation
Without measurement there is no control
B E N E F I T S• Designed specifically for pharmaceutical
environmental monitoring
• Integration and control of viable and non-viable sampling
• High data integrity
• Ultimate efficiency and reduced error
• Simple installation and validation
• Flexible integration
A P P L I C AT I O N SMonitoring of critical environments including:
• Filling lines
• Isolators and RABS
• Blow-Fill-Seal
• Lyophilizer processes and transfer carts
• Biosafety cabinets and flow hoods
• General cleanroom and facility monitoring
Viable/Nonviable/Environmental Monitoring
FacilityPro® software provides the interface, supervisory control, data management, and reporting functionality for an environmental monitoring system. FacilityPro’s ability to manage viable, nonviable, and environmental data through a common system improves the efficiency of production operations and quality investigations.
Industrial Automation Architecture
With the FacilityPro industrial automation architecture, the data processing is performed by the Processor while the data management, display, and storage are performed by the software. This design approach increases system reliability and data integrity.
Two Main Versions
FacilityPro software is available in two main versions:
• FacilityPro SCADA Server software
• FacilityPro SMART Server module
Both software platforms offer a number of intelligent features including data mapping, alarming, reporting, and recipe-driven sampling. Both also offer client software for remote access and viewing of data. The SCADA version is built on the GE® Proficy® iFIX® SCADA platform and Historian database and provides several additional advanced features.
FacilityPro® SoftwareData Management, Reporting, and Automation
FacilityPro SMART Server ModuleThe FacilityPro SMART Server is a stand-alone module that interfaces with one FacilityPro Processor per SMART module and provides a simple monitoring and reporting tool. By distributing the data processing to the FacilityPro Processor, the FacilityPro SMART server delivers high reliability and data integrity.
The FacilityPro SMART server is 21 CFR 11 compliant and provides the user with a number of tools to improve efficiency and reduce error:
• Map for visual indication of viable, nonviable, and environmental status
• Configurable display
• Alarm notification and e-signature acknowledgement
• Configurable reports including audit, statistics, and trend reports
• Batch identifiers and data filters
• Automation of sample collection, driven by recipes
• Cubic-meter algorithms for nonviable data
• Volume-based or time-based viable sampling
• Client software for remote viewing and reporting
• 12 interface languages supported
HMI Client
FacilityPro SMART Server
Server Network
Client Netw
ork (maxim
um 2 clients)
Client StationFacilityPro® Processor
Cleanroom Sensors
Alarms and I/O
Sensor Network
I/O Signals
(1 per SMART Server)
Display resolution 1280 x 1024 minimum
Minimum requirement client CPU i5 3 GHz, RAM 8 GB, HD 500.0 GB, 2 Ethernet, 1 DVD/RW, 4 USB Ports
Operating system clients Windows® 7 Ultimate – 64bit
Specifications
FacilityPro® SoftwareData Management, Reporting, and Automation
FacilityPro SCADA Server SoftwareThe FacilityPro SCADA Server software is built on GE’s Proficy iFIX SCADA platform and Historian database. The SCADA Server software supports all the same features as the SMART Server, with the addition of the following advanced features:
• Redundant server capability
• Supports multiple FacilityPro Processors
• Supports third-party PLC integration
• Supports SMS and Email-sending software package
• Supports FacilityPro WebSpace software, providing remote access to the Server through a web browser or tablet app
• iOS (iPad®) and AndroidTM app (works in conjunction with WebSpace)
FacilityPro® Processor
HMI Clients
FacilityPro SCADA Server
FacilityPro WebSpaceServer N
etwork
Client Netw
ork
Client Stations
Tablet Thin ClientRedundant SCADA ServerCleanroom Sensors
Sensor Network
I/O Signals
(max 5 per SCADA Server)
FacilityPro® Processor
(max 5 per SCADA Server)
Alarms and I/O
Cleanroom Sensors Alarms and I/O
Sensor NetworkI/O Signals
Minimum requirement client CPU i5 3 GHz, RAM 8 GB, HD 500.0 GB, 3 Ethernet, 1 DVER/RW, 4 USB Ports
Operating Systems Windows 7 Professional – 64bit – English or Operative System, Windows Server Essentials – 2012 R2 – 64bit – English
Specifications
HEADQUARTERS 5475 Airport BlvdBoulder, Colorado 80301 USAT: +1 303 443 7100, +1 800 238 1801
Instrument Service & SupportT: +1 800 557 6363Customer Response CenterT: +1 877 475 3317E: [email protected]
GLOBAL OFFICES BRAZILT: +55 11 5188 8227 E: [email protected]
CHINA T: +86 21 6113 3600E: [email protected]
FRANCET: +33 (0)6 82 99 17 98E: [email protected]
GERMANY T: +49 6151 6671 632E: [email protected]
ITALY T: +39 06 9053 0130 E: [email protected]
JAPAN T: +81 3 5298 8175 E: [email protected]
KOREA T: +82 31 286 5790 E: [email protected]
MEXICO T: +52 55 2271 5106 E: [email protected]
NORDIC T: +45 707 028 55 E: [email protected]
PUERTO RICOT: +1 787 718 9096 E: [email protected]
SINGAPORET: +65 6496 0330 E: [email protected]
SWITZERLANDT: +41 71 987 01 01E: [email protected]
TAIWANT: 886-3-5525300 Ext: 301E: [email protected]
UNITED KINGDOMT: +44 1684 581 000 E: [email protected]
FacilityPro® SoftwareData Management, Reporting, and Automation
2016.06
FacilityPro® is a registered trademark of Particle Measuring Systems, Inc.GE®, iFIX® and Proficy® are all trademarks of General Electric.
iPad is a registered trademark of Apple, Inc.iOS® is a registered trademark of Cisco.
Android™ is a trademark of Google, Inc.Windows® is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.Particle Measuring Systems, Inc. reserves the right to change specifications without notice.
© 2016 Particle Measuring Systems, Inc. All rights reserved.
Feature Comparison
Top Related