EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13
LUMINAIRE PHOTOMETRIC TEST REPORT
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,113.9
UNIT:cd
C30/210,113.1
UNIT:cd
C60/240,113.0
UNIT:cd
C90/270,113.1AVERAGE BEAM ANGLE(50%):113.3 DEG
0
300
600
900
1200
1500
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 17.0 34.0
S(m)8.20
6.80
5.40
4.10
2.70
1.40
1.10
0.6800
0.5400
0.4100
DATA OF LAMP PHOTOMETRIC DATA Eff: 107.74 lm/W
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
CIE CLASS
up(%)
down(%)
S/MH(C0/180)
S/MH(C90/270)
UP,DN(C0-180)
UP,DN(C180-360)
CIBSE SHR NOM
CIBSE SHR MAX
35
120-277
3764.61
1
120
1359
100.0
3764.6
DIRECT
0.0
100.0
1.28
1.26
0.0,50.0
0.0,50.0
1.25
1.35
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
ASD-BLP-22A35AC-EM(3000K)
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 13
ZONAL FLUX DIAGRAM
ZONAL FLUX DIAGRAM:
10 0- 10
20 10- 20
30 20- 30
40 30- 40
50 40- 50
60 50- 60
70 60- 70
80 70- 80
90 80- 90
100 90-100
110 100-110
120 110-120
130 120-130
140 130-140
150 140-150
160 150-160
170 160-170
180 170-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp
DEG LUMINOUS INTENSITY:cd UNIT:lm
1331 1320 1324 1327 1341 1327 1325 1320 127.8 127.8 3.29,3.29
1259 1259 1257 1272 1277 1273 1257 1259 366.8 494.6 12.7,12.7
1144 1136 1156 1154 1170 1154 1155 1136 557.1 1052 27.1,27.1
990.0 994.0 996.8 1015 1022 1013 994.6 993.3 674.7 1726 44.5,44.5
804.0 804.5 815.0 826.4 841.2 822.7 811.9 802.6 702.8 2429 62.6,62.6
594.7 599.4 611.0 619.9 634.1 613.6 607.2 596.9 638.3 3068 79,79
375.8 386.1 391.7 402.0 413.6 392.4 384.1 382.6 494.6 3562 91.8,91.8
167.8 153.3 0 162.1 201.1 151.5 0 148.5 283.4 3846 99.1,99.1
15.81 0 0 0 28.21 0 0 0 35.54 3881 100,100
Conical surface Flux(90deg): 2080 lm
%lum = 53.6%
%lamp = 53.6%
Conical surface Flux(120deg): 3067.5 lm
%lum = 79.0%
%lamp = 79.0%
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 13
LUMINANCE LIMITATION CURVES
LUMINANCE LIMITATION CURVES
GLARE CLASS ILLUMINANCE (lx)
1.15 A 2000 1000 500 <=300
1.50 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.20 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 41
2
3
4
68
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)
G(DEG) C0/180 C90/270
85 2718 0
80 3081 0
75 3312 3475
70 3504 3652
65 3664 3783
60 3793 3897
55 3901 3964
50 3989 4043
45 4061 4135
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 13
WEC AND CCEC
cc
w
fc
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.303
.289
.269
.249
.230
.214
.199
.186
.174
.164
.172
.158
.143
.129
.117
.107
.098
.091
.084
.079
.055
.049
.043
.038
.034
.031
.028
.026
.024
.022
.296
.283
.263
.244
.226
.210
.196
.183
.171
.161
.169
.156
.141
.128
.116
.106
.097
.090
.084
.078
.054
.048
.042
.038
.034
.031
.028
.025
.023
.022
.282
.271
.253
.235
.218
.203
.189
.177
.166
.157
.162
.151
.137
.125
.113
.104
.096
.088
.082
.077
.052
.047
.042
.037
.033
.030
.028
.025
.023
.022
.270
.260
.244
.226
.210
.196
.183
.172
.161
.152
.156
.146
.133
.121
.111
.102
.094
.087
.081
.076
.050
.046
.041
.037
.033
.030
.027
.025
.023
.021
.259
.251
.235
.218
.203
.189
.177
.166
.157
.148
.150
.142
.130
.119
.109
.100
.092
.085
.080
.074
.048
.045
.040
.036
.033
.030
.027
.025
.023
.021
cc
w
fc
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.190
.180
.172
.164
.157
.149
.142
.135
.129
.123
.117
.190
.156
.132
.114
.101
.091
.082
.075
.070
.065
.060
.190
.135
.098
.074
.058
.047
.039
.033
.029
.025
.022
.163
.154
.147
.141
.135
.128
.122
.117
.111
.106
.101
.163
.134
.114
.099
.087
.078
.071
.065
.060
.056
.052
.163
.116
.085
.065
.051
.041
.034
.029
.025
.022
.020
.111
.105
.101
.097
.093
.088
.084
.081
.077
.073
.070
.111
.092
.079
.068
.061
.055
.050
.046
.042
.039
.037
.111
.080
.059
.045
.036
.029
.024
.020
.018
.016
.014
.064
.061
.058
.056
.054
.051
.049
.047
.045
.043
.041
.064
.053
.046
.040
.036
.032
.029
.027
.025
.023
.022
.064
.047
.035
.027
.021
.017
.014
.012
.011
.009
.008
.020
.019
.019
.018
.017
.016
.016
.015
.014
.014
.013
.020
.017
.015
.013
.012
.010
.010
.009
.008
.008
.007
.020
.015
.011
.009
.007
.006
.005
.004
.003
.003
.003
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 13
UGR(Unified Glare Rating) Table
ceiling/cavity
walls
working plane
Room dimensions Viewed crosswise Viewed endwise
0.7 0.7
0.5 0.5
0.2 0.2
0.7 0.7
0.3 0.3
0.2 0.2
0.5 0.5
0.5 0.5
0.2 0.2
0.5 0.5
0.3 0.3
0.2 0.2
0.3 0.3
0.3 0.3
0.2 0.2
x = 2H y = 2H
3H
4H
6H
8H
12H
4H 2H
3H
4H
6H
8H
12H
8H 4H
6H
8H
12H
12H 4H
6H
8H
17.6 17.7 19.1 19.2 17.8 18.0 19.3 19.4 19.5 19.6
19.1 19.3 20.5 20.7 19.4 19.6 20.8 20.9 21.0 21.2
19.8 20.0 21.1 21.3 20.1 20.3 21.4 21.5 21.6 21.8
20.2 20.0 21.5 21.3 20.6 20.4 21.8 21.6 22.0 21.8
20.4 20.0 21.6 21.2 20.7 20.3 21.9 21.5 22.1 21.8
20.4 19.9 21.6 21.1 20.8 20.3 21.9 21.4 22.2 21.7
18.2 18.3 19.6 19.7 18.5 18.6 19.8 19.9 20.1 20.2
20.0 20.1 21.1 21.3 20.3 20.5 21.4 21.6 21.7 21.9
20.7 20.9 21.8 22.0 21.1 21.3 22.1 22.3 22.5 22.6
21.3 21.0 22.2 22.0 21.7 21.4 22.6 22.3 23.0 22.7
21.5 21.0 22.4 21.9 21.9 21.4 22.7 22.2 23.1 22.6
21.6 20.9 22.4 21.7 22.0 21.4 22.8 22.1 23.2 22.5
21.1 21.2 21.9 22.1 21.5 21.6 22.3 22.4 22.7 22.8
21.8 21.4 22.5 22.1 22.2 21.8 22.9 22.5 23.3 22.9
22.1 21.3 22.7 22.0 22.5 21.8 23.1 22.4 23.6 22.9
22.3 21.3 22.8 21.9 22.7 21.8 23.3 22.3 23.7 22.8
21.0 21.2 21.8 22.0 21.5 21.6 22.2 22.4 22.6 22.8
21.8 21.4 22.4 22.1 22.2 21.9 22.9 22.5 23.3 22.9
22.1 21.4 22.6 21.9 22.5 21.8 23.1 22.4 23.6 22.8
Variations with the observer position at spacings:
S = 1.0H + 0.1 / - 0.2 + 0.2 / - 0.2
1.5H + 0.2 / - 0.3 + 0.1 / - 0.2
2.0H + 0.2 / - 0.2 + 0.2 / - 0.4
CIE Pub.117, 3881 lm Total Lamp Luminous Flux Corrected (8log(F/F0) = 4.7)
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 13
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 57 46 39 57 46 39 56 45 39 32
0.80 68 56 49 66 55 48 65 55 48 41
1.00 76 65 58 75 64 57 73 66 57 50
1.25 83 73 66 82 72 65 79 70 64 57
1.50 88 78 71 87 77 71 83 76 70 62
2.00 95 87 80 93 85 79 90 83 78 70
2.50 99 91 85 97 90 84 93 87 83 74
3.00 102 96 90 100 94 89 96 91 87 79
4.00 107 101 96 104 99 95 100 96 92 83
5.00 109 104 100 107 102 99 102 99 96 87
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 13
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
HORIZONTAL(DEG)
VERTICAL(DEG)
Imax:1359(H-1.0,V0.0)
(At:C=180.0,Gamma=1.0)
UNIT: cd
10% 135.920% 271.930% 407.840% 543.850% 679.760% 815.670% 951.680% 108890% 1223
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 13
AAI Figure
1m 303.02cm387.7,1359lx
2m 606.05cm96.92,339.8lx
3m 909.07cm43.07,151.0lx
4m 1212.09cm24.23,84.94lx
5m 1515.12cm15.51,54.36lx
6m 1818.14cm10.77,37.75lx
7m 2121.16cm7.912,27.74lx
8m 2424.19cm6.057,21.24lx
9m 2727.21cm4.786,16.78lx
10m 3030.24cm3.877,13.59lx
Height Eavg,Emax DiameterAngle:113.15deg
Flux out:2888 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 13
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)
0
1.5
3
4.5
6
7.5
9
10.5
12
13.5
15E(lx) MH = 10 m
C0/180
C90/270
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 13
LUMINOUS DISTRIBUTION INTENSITY DATA
(DEG)
C(DEG)
Table--1 UNIT: cd
0
0 1359
5 1351
10 1331
15 1301
20 1259
25 1206
30 1144
35 1071
40 990
45 901
50 804
55 702
60 595
65 486
70 376
75 269
80 168
85 74.3
90 15.8
5
1359
1349
1328
1296
1253
1200
1137
1064
982
892
796
694
589
481
375
268
160
61.7
0.00
10
1359
1348
1326
1293
1250
1196
1133
1060
980
892
798
699
593
482
376
268
150
67.8
0.00
15
1359
1347
1324
1291
1247
1195
1133
1062
984
899
800
696
591
488
376
266
155
71.5
0.00
20
1359
1346
1322
1289
1247
1195
1135
1067
988
895
798
699
598
486
379
267
162
67.7
0.00
25
1359
1345
1321
1289
1247
1197
1140
1068
983
894
802
704
594
488
379
270
168
34.2
0.00
30
1359
1344
1320
1289
1249
1202
1141
1064
983
898
807
701
596
490
381
275
173
0.00
0.00
35
1359
1343
1320
1289
1251
1207
1138
1063
986
905
803
701
601
490
383
278
175
0.00
0.00
40
1359
1343
1320
1290
1254
1203
1136
1065
991
901
803
705
600
491
385
279
177
0.00
0.00
45
1359
1342
1320
1292
1259
1201
1136
1068
994
900
804
709
599
492
386
280
153
0.00
0.00
50
1359
1342
1320
1294
1259
1200
1137
1073
991
900
808
708
600
494
387
281
124
0.00
0.00
55
1359
1342
1320
1296
1257
1200
1139
1078
990
901
812
707
601
496
388
281
96.6
0.00
0.00
60
1359
1342
1321
1298
1256
1200
1142
1076
990
903
813
707
602
497
388
281
72.1
0.00
0.00
65
1359
1341
1321
1300
1255
1201
1145
1075
990
906
812
708
604
498
389
281
50.7
0.00
0.00
70
1359
1341
1322
1302
1255
1202
1148
1074
991
909
812
709
606
498
389
281
32.8
0.00
0.00
75
1359
1341
1323
1303
1255
1203
1151
1074
993
911
812
710
607
499
390
281
18.6
0.00
0.00
80
1359
1342
1323
1305
1255
1204
1153
1075
994
914
813
711
609
500
390
281
8.34
0.00
0.00
85
1359
1342
1324
1306
1256
1206
1155
1076
996
915
814
712
610
500
391
281
2.10
0.00
0.00
90
1359
1342
1324
1307
1257
1207
1156
1077
997
917
815
713
611
501
392
282
0.00
0.00
0.00
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 13
LUMINOUS DISTRIBUTION INTENSITY DATA
(DEG)
C(DEG)
Table--2 UNIT: cd
95
0 1359
5 1342
10 1325
15 1308
20 1258
25 1207
30 1157
35 1078
40 998
45 918
50 816
55 714
60 612
65 502
70 393
75 283
80 2.11
85 0.00
90 0.00
100
1359
1342
1325
1308
1259
1208
1157
1079
999
918
818
715
613
503
394
284
8.43
0.00
0.00
105
1359
1343
1325
1307
1260
1209
1157
1081
1000
918
820
716
613
504
395
285
18.9
0.00
0.00
110
1359
1343
1326
1307
1261
1209
1156
1083
1001
918
822
718
614
506
396
286
33.5
0.00
0.00
115
1359
1343
1326
1306
1263
1210
1155
1086
1002
918
824
719
614
507
397
288
52.1
0.00
0.00
120
1359
1344
1326
1305
1265
1211
1154
1089
1004
918
828
721
615
508
398
289
74.4
0.00
0.00
125
1359
1344
1326
1304
1268
1212
1154
1093
1006
918
829
724
616
510
400
291
100
0.00
0.00
130
1359
1345
1326
1303
1272
1214
1153
1090
1010
919
827
727
618
510
401
292
130
0.00
0.00
135
1359
1346
1327
1302
1272
1217
1154
1088
1015
921
826
731
620
511
402
294
162
0.00
0.00
140
1359
1347
1327
1301
1270
1221
1156
1087
1014
925
827
729
623
512
403
294
188
0.00
0.00
145
1359
1348
1328
1301
1267
1227
1160
1087
1011
931
830
728
628
514
402
293
187
0.00
0.00
150
1359
1348
1329
1301
1265
1222
1165
1090
1010
926
836
730
625
517
402
290
185
0.00
0.00
155
1359
1349
1330
1301
1264
1218
1165
1096
1013
925
833
735
625
517
403
287
181
37.4
0.00
160
1359
1350
1331
1303
1264
1217
1160
1096
1020
928
832
733
631
516
404
285
175
75.0
0.00
165
1359
1352
1333
1305
1266
1217
1159
1092
1017
935
838
734
628
522
405
287
171
79.5
0.00
170
1359
1353
1335
1307
1268
1218
1159
1090
1013
928
836
739
633
520
409
293
172
76.9
0.00
175
1359
1354
1338
1311
1272
1222
1163
1093
1015
928
834
734
629
521
415
304
187
79.8
0.00
180
1359
1356
1341
1315
1277
1228
1170
1101
1022
936
841
740
634
524
414
305
201
105
28.2
185
1359
1354
1338
1311
1272
1222
1163
1093
1014
928
833
733
627
519
411
300
193
92.9
0.00
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 12 Of 13
LUMINOUS DISTRIBUTION INTENSITY DATA
(DEG)
C(DEG)
Table--3 UNIT: cd
190
0 1359
5 1353
10 1335
15 1307
20 1268
25 1218
30 1159
35 1090
40 1012
45 927
50 835
55 737
60 630
65 517
70 406
75 296
80 190
85 86.3
90 0.00
195
1359
1352
1333
1305
1266
1217
1158
1091
1016
934
836
731
624
517
403
294
184
83.8
0.00
200
1359
1350
1332
1303
1264
1217
1160
1096
1019
927
830
730
627
512
402
289
182
75.3
0.00
205
1359
1349
1330
1302
1264
1219
1165
1096
1012
923
830
732
620
511
399
287
181
36.6
0.00
210
1359
1349
1329
1301
1265
1222
1165
1090
1009
924
833
726
619
511
396
286
179
0.00
0.00
215
1359
1348
1328
1301
1267
1226
1159
1086
1009
928
827
723
622
506
394
284
178
0.00
0.00
220
1359
1347
1327
1302
1270
1221
1156
1086
1012
922
823
725
617
504
394
283
176
0.00
0.00
225
1359
1346
1327
1302
1273
1217
1154
1086
1013
918
823
726
614
503
392
282
151
0.00
0.00
230
1359
1345
1327
1303
1272
1214
1153
1089
1008
916
824
722
612
503
391
281
122
0.00
0.00
235
1359
1345
1326
1305
1269
1212
1153
1091
1004
915
825
719
610
502
390
279
94.9
0.00
0.00
240
1359
1344
1326
1306
1266
1211
1154
1088
1001
915
824
717
610
501
389
277
70.5
0.00
0.00
245
1359
1344
1326
1307
1264
1210
1155
1085
1000
915
821
715
609
500
388
276
49.6
0.00
0.00
250
1359
1343
1326
1308
1262
1209
1155
1082
999
916
818
713
609
499
387
275
32.0
0.00
0.00
255
1359
1343
1326
1308
1260
1208
1156
1079
998
916
816
712
609
498
386
274
18.1
0.00
0.00
260
1359
1343
1326
1308
1259
1208
1156
1078
997
916
815
711
608
497
385
273
8.10
0.00
0.00
265
1359
1342
1325
1308
1258
1207
1156
1076
996
915
813
710
608
496
384
273
2.03
0.00
0.00
270
1359
1342
1325
1308
1257
1206
1155
1075
995
914
812
710
607
496
384
272
0.00
0.00
0.00
275
1359
1342
1324
1307
1256
1205
1154
1074
994
913
811
709
606
495
384
273
2.03
0.00
0.00
280
1359
1342
1324
1306
1256
1204
1152
1073
992
911
810
708
605
495
384
273
8.09
0.00
0.00
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 13 Of 13
LUMINOUS DISTRIBUTION INTENSITY DATA
(DEG)
C(DEG)
Table--4 UNIT: cd
285
0 1359
5 1342
10 1323
15 1305
20 1256
25 1203
30 1150
35 1073
40 991
45 909
50 810
55 707
60 604
65 494
70 384
75 273
80 18.1
85 0.00
90 0.00
290
1359
1342
1323
1303
1256
1202
1147
1073
990
906
810
706
603
494
384
274
31.9
0.00
0.00
295
1359
1342
1322
1301
1256
1201
1145
1074
989
904
810
705
601
494
384
274
49.3
0.00
0.00
300
1359
1342
1321
1299
1257
1200
1142
1075
988
901
811
705
600
494
383
275
70.0
0.00
0.00
305
1359
1342
1321
1296
1258
1200
1139
1077
989
899
810
705
598
493
383
275
93.7
0.00
0.00
310
1359
1342
1320
1294
1260
1200
1137
1072
990
898
806
705
597
492
383
275
120
0.00
0.00
315
1359
1343
1320
1292
1259
1202
1136
1068
993
898
803
707
597
490
383
275
148
0.00
0.00
320
1359
1343
1320
1291
1256
1204
1136
1065
990
900
801
703
597
488
382
275
172
0.00
0.00
325
1359
1344
1320
1290
1252
1208
1138
1064
985
904
802
700
599
487
380
274
172
0.00
0.00
330
1359
1344
1321
1289
1250
1202
1142
1065
983
897
806
699
594
488
378
274
172
0.00
0.00
335
1359
1345
1322
1289
1248
1198
1141
1069
983
894
801
703
592
485
377
272
171
34.8
0.00
340
1359
1346
1323
1290
1247
1196
1136
1068
988
895
797
698
596
483
376
269
170
70.5
0.00
345
1359
1347
1324
1291
1248
1195
1133
1062
984
899
801
696
590
486
374
268
168
76.4
0.00
350
1359
1348
1326
1293
1250
1196
1133
1061
980
892
798
699
592
481
373
267
166
74.8
0.00
355
1359
1349
1329
1297
1253
1200
1137
1064
982
892
796
694
588
481
373
265
164
71.4
0.00
H( ) Range:-90 - 90DEGH( ) Interval: 1.0DEG
V(B) Range:-75 - 75DEGV(B) Interval: 5.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.364Temperature:29.6DEG Humidity:42%
Test Distance:8.350m [K=1.0000]Operators:ZackTest Date:2020-04-30 Remarks:
SPEC.:ASD-BLP-22A35AC-EM(3000K)
MFR.: ASD Lighting corp
Test:U:121.5V I:0.2900A P:34.94W PF:0.9912 Freq:59.98Hz Lamp Flux:3764.61x1 lm
NAME: ASD Lighting corp TYPE:Back-lit LED Panel
DIM.: 2x2
SUR.:0.56x0.56m
WEIGHT:
SERIAL No.:
Shielding Angle: