Stratus Workstation™ shown with standard configurations, other features sold separately.
Ergonomic Products Performance Without Compromise®
Product
ID: 950 – 053 Rev:
Rev:
D1E A
D1E Series: Stratus Workstation™
Specification and Installation
Guide
D1E Series: Stratus Workstation™
PAGE 2
D1E manual
Thank you for purchasing the Ergonomic Products D1E Series: Stratus Workstation™
Years of research by dentists, engineers and designers have made this a uniquely effective
product in the industry. We stand behind our equipment, and genuinely believe it to be the best
available on the market.
Should you have any questions regarding the product’s installation or use, please don’t hesitate
to call our customer service specialists at 1-866-ERGO-4-US. We may also be reached via
email at [email protected].
We hope you enjoy the benefits and quality of your new equipment and look forward to handling
your future needs as you and your practice continue to grow!
- The Ergonomic Products Team
Call our Customer Service Specialists at:
1-866-ERGO-4-US
QUESTIONS?
CONTENTS:
1. Introduction…….…….……………………………….3
2. Specifications………………………………………….6
3. Basic Anatomy of the Workstation …………7
4. Unpacking and Inspecting..…………………….8
5. Workstation Installation…………….…………14
6. Worksurface Height Adjustment…………..16
7. Umbilical Installation…………………………….17
8. Power Channel Maintenance…………………20
9. Cleaning and Disinfecting……………………...26
10. Warranty Information…………………………..28
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
The following symbols are used in this manual and on product labels.
Symbol Meaning
This symbol means that you must refer to the documentation that came with your device.
This symbol indicates a Warning. Warnings alert the user to the possibility of serious injury or death if the equipment is not operated properly.
This symbol indicates that the device is a Type BF piece of equipment and has a certain degree of protection against electric shock. The BF Type applied part extends from the patient into the equipment and is isolated from all other parts of the equipment.
This symbol indicates that you must not dispose of any electronic components along with general waste.
This symbol appears next to the manufacturer’s contact information.
This symbol appears next to the date of manufacture.
This symbol Indicates Pushing Prohibited.
All product names used in this guide are trademarks of their respective owners.
D1E Series: Stratus Workstation™
PAGE 3
D1E manual
1 – INTRODUCTION
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
The following symbols are used in this manual and on product labels.
Symbole Sens
Ce symbole signifie que vous devez vous référer à la documentation fournie avec votre appareil.
Ce symbole indique un avertissement. Avertissements alerter l'utilisateur de la possibilité de blessures graves ou la mort si l'appareil ne fonctionne pas correctement.
Ce symbole indique que l'appareil est un élément type BF de l'équipement et a un certain degré de protection contre les chocs électriques. Le type BF s'étend du patient dans l'appareil et est isolée de toutes les autres parties de l'équipement.
Ce symbole indique que vous ne devez pas disposer de tous les composants électroniques avec les déchets ordinaires.
Ce symbole apparaît à côté de l'autre aux coordonnées du fabricant.
Ce symbole apparaît à côté de la date de fabrication.
Ce symbole indique Pousser interdite
Tous les noms de produits mentionnés dans ce guide sont des marques
commerciales de leurs propriétaires respectifs.
D1E Series: Stratus Workstation™
PAGE 4
D1E manual
1 – INTRODUCTION CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
INTENDED USE The Ergonomic Products Workstation is a dental operative unit, which is an AC-powered device that is intended to supply power to and serve as a base for other dental devices and accessories. The device is to be operated and used by dentists and other legally qualified professionals.
CONTRAINDICATIONS There are no known contraindications for the use of this device.
WARNINGS Warnings alert the user to the possibility of serious injury or death if the equipment is not operated properly.
Only properly trained and authorized personnel must use this equipment. Do not modify this equipment without authorization from Ergonomic Products, Inc. Read and understand all warnings, precautions, and operating instructions before use. To avoid risk of electric shock, connect this equipment only to an electrical supply with a protective earth ground. Do not bypass the grounding circuitry. The device might cause interference with other electronic devices while in use. Ensure that other medical devices used in the treatment office do not receive interference from this device. A dental unit might include magnets which might affect the function or programming of some implantable pacemakers or defibrillators. People who have devices programmed to respond to a magnet must avoid dental units with magnets. Improper installation of the syringe can result in injury or damage. Refer to the syringe manufacturer’s documentation for instructions on proper installation and use.
Do not position equipment so it is difficult to operate the disconnect device. Do not use a socket multiplier or an extension cord to connect the Workstation to the electrical supply.
To avoid the risk of electric shock, do not connect equipment that must be connected a multi-socket outlet with a
separating transformer directly to an electrical wall outlet.
Connect only those items that are part of the Workstation or have been approved by Ergonomic Products, Inc. to
be compatible with the Workstation.
It is mandatory that metal reusable syringe tips are sterilized between each patient to prevent cross
contamination. Please follow the manufacturer’s recommended practices for sterilization.
D1E Series: Stratus Workstation™
PAGE 5
D1E manual
1 – INTRODUCTION CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
D1E Series: Stratus Workstation™
PAGE 6
D1E manual
2 – SPECIFICATIONS
• 2 High/Low Speed Air • 1 EP Mega Tub
• 1 A/W Syringe • 1 HVE
• 1 Saliva Ejector
• 2 Small Sharps Container
• 2 Liter Water Bottle
• Standard Foot Pedal
• Power Channel swings 180⁰ for complete
Left / Right convertibility
• Keyboard Slide
• Quick Connect™ Umbilical Connection
• Waste Receptacle
• Recessed Bur Detents Milled Into Surface
• Rear Panel 120V Power Outlet & USB Connection
• Rear Panel Auxiliary Air & Water
• Corian Staging Tray
• Powder Coated Top Tier / Magnetic Surface
• 1 EP Consumable Bin
STANDARD FEATURES
OPTIONAL FEATURES
• Bien Air Electric Hand Piece (1st and/or 2nd Position)
• 3rd Air Driven Slow Speed Handpiece
• 2nd High Volume Suction
• 1 Dedicated Air Syringe
• 2nd Air/Water Syringe
• Auto/Manual Tune Scaler W/ Foot Pedal and Scaler push button
• Cure Light
• Magnetic Compsite Gun Holder (1 to 3)
• Fiber Optic Hose (1st or 2nd Position)
• City Water Connection
Electrical Specifications*
Electric 120VAC, 60HZ, 8A (Max) Fuse Value Label at Point of Use Conforms to
US/ANSI/AAMI ES60601-1 2005+C1+A2 CA/CNCSA-C22.2 No. 60601-1 Air, Water, Electric Auxiliary
Air, 3/8 Dental Style Female QD, 80 psi Water, ¼ Dental Style Female QD, 30-35 psi Electric Outlet, 120VAC. 60HZ, 4A* Storage and Transportation Conditions
-30° C to +50 C 10% to 90% Relative Humidity Standard Atmospheric Pressure Use Conditions
Typical Dental Office Environment Standard Atmospheric Pressure Materials
Corian Solid Surface, Aluminum, Stainless Steel, and Powder-Coated Steel *Refer to specific manufacturer’s documentation or the actual transformer for input and output voltages, amp ratings, and Hz ratings.
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
The below pictorial reflects the standard options for the Stratus Workstation™
D1E Series: Stratus Workstation™
PAGE 7
D1E manual
3 – BASIC ANATOMY OF THE WORKSTATION
Corian Work
Surface
2L Water
Bottle
Waste Bin
Mega Tub
Bin
Power Coated Magnetic
Top Tier Surface
Umbilical Tube Power Channel
(Bien Air Shown)
ConsumableBin
Sharps
Bin (2)
Foot Pedal
Key Board
Pull out Tray
Corian Staging Tray
Quick Connect to J-box
Assistant Utilities
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
D1E Series: Stratus Workstation™
PAGE 8
D1E manual
4 – UNPACKING and INSPECTING
REQUIRED TOOLS
Utility Knife
5/32” Allen Wrench
3/16” Allen Wrench
1. Inspect shipping container (Fig 4.1) for visible damage upon arrival. If transit damage is found, contact Ergonomic Products immediately. (This will expedite the corrective process). 2. Use safe lifting procedures to free the product from the container, and remove all packing material and accessory boxes from shipping container (Fig 4.2). 3. Lay individual components on clean surface to avoid scratching, and inspect contents. If damage is found, contact Ergonomic Products immediately. 4. Do not discard accessory boxes without thoroughly checking them for emptiness.
Fig 4.1
Accessory Boxes
Fig 4.2
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
The below products come standard with the Stratus Workstation™
(1) Bin frame with attached Corian Staging Tray, Magnetic Top Tier, and Keyboard Slide
Rear Panel 120V Power Outlet and USB Connection with Auxiliary Air & Water
(2) Medical Sharps Bin and (1) Consumable Bin
D1E Series: Stratus Workstation™
PAGE 9
D1E manual Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
4 – UNPACKING and INSPECTING CONT’D
STANDARD
PARTS LIST
Check that the configuration/options for your product(s) are correct. If anything is damaged or missing, please contact Ergonomic Products customer service at 1-866-ERGO-4-US.
The below products come standard with the Stratus Workstation™
(1) 13 gallon stainless steel waste bin
(1) Standard Foot Pedal
D1E Series: Stratus Workstation™
PAGE 10
D1E manual
4 – UNPACKING and INSPECTING CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
STANDARD PARTS
LIST CONT’D
Check that the configuration/options for your product(s) are correct. If anything is damaged or missing, please contact Ergonomic Products customer service at 1-866-ERGO-4-US.
The below products are options with the Stratus Workstation™
(1) Bien Air MX II Electric Handpiece
Refer to Bien Air’s documentation for proper operation of the Bien Air MX II electric handpiece. The Bien Air MX II comes with a
faceplate-mounted control pad, internally mounted driver board, and a proprietary handpiece hose. A transformer plugs into a 120-volt outlet in the utility area with low voltage power supplied to the
driver board through the umbilical. Power to the circuit is disconnected when the master switch is shut off.
3rd hose for air driven handpiece available in 4 hole ISO B, 5 hole ISO B or 6-hole ISO C tubing.
Dedicated Air Syringe
2nd Air/Water Syringe
D1E Series: Stratus Workstation™
PAGE 11
D1E manual
4 – UNPACKING and INSPECTING CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
UPGRADES FOR YOUR
WORKSTATION
Check that the configuration/options for your product(s) are correct. If anything is damaged or missing, please contact Ergonomic Products customer service at 1-866-ERGO-4-US.
The below products are options with the Stratus Workstation™
(1) Fiber Optic ISO-B 5 Hole Hose 48”
The delivery system of the Ergonomics Products Workstation* has
been designed to be compatible with air driven handpieces that conform to ISO 9168. When the Bien Air MX II option is installed,
the system is also compatible with electric handpieces that conform to ISO 11498.
Dental units for electric handpieces are equipped with a proprietary Bien Air tubing and motor with a standard E-type coupler. The end user has responsibility to acquire appropriate handpieces for use with the Workstation. Your country might have certain regulations
in regards to what handpieces are acceptable to use. Refer to your local dealer for more information.
For instructions and details about accessories provided from other manufacturers, refer to their product documentation.
*Models May Vary
2nd HVE Hand Peice
If Curing Light provided, refer to manufacturer’s documentation for
proper operation of the curing light for the workstation
D1E Series: Stratus Workstation™
PAGE 12
D1E manual
4 – UNPACKING and INSPECTING CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
UPGRADES FOR YOUR
WORKSTATION
Check that the configuration/options for your product(s) are correct. If anything is damaged or missing, please contact Ergonomic Products customer service at 1-866-ERGO-4-US.
The below products are options with the Stratus Workstation™
1 – 3 Magnetic Gun Holders
Scaler Refer to Parkell’s documentation for proper operation of the Parkell Auto Manual Tune D959 (Other Parkell scaler options are available through Ergonomic Products, please contact your sales representative for more information). The control box for the scaler is mounted on the top front of the Power Channel on guide rails that allow the unit to slide back for access to the vacuum canister. The power supply is plugged in with other utilities and the wiring runs through the umbilical to an outlet on the back of the Power Channel. Next to the power outlet on the back of the Power Channel is a foot control connection that connects to an internally mounted air electric switch. Activate this air electric switch by pressing the small button on the rheostat. The two short cables and water line from the Parkell unit make their connections on the back of the Power Channel. Other Parkell scalers install in the same manner, except only the foot control that comes with the unit is used as the air electric switch and associated wiring and plumbing are omitted.
D1E Series: Stratus Workstation™
PAGE 13
D1E manual
4 – UNPACKING and INSPECTING CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
UPGRADES FOR YOUR
WORKSTATION
Check that the configuration/options for your product(s) are correct. If anything is damaged or missing, please contact Ergonomic Products customer service at 1-866-ERGO-4-US.
D1E Series: Stratus Workstation™
STEP 1 – SECURE TOP TIER FRAME TO WORKSTATION BASE
STEP 2 – INSERT BINS INTO PLACE
PAGE 14
D1E manual
5 – WORKSTATION INSTALLATION
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. There are 4 Button Socket Cap Screws pre-installed
on the underside of the Corian Work Surface (Fig 5.1).
Remove the screws and line up the Top Tier Frame to
be secured to the Work Surface with the Socket Cap
Screws (Fig 5.2).
2. Use a 5/32” Allen Wrench to tighten screws to the
Worktop and secure the Top Tier Frame in place.
Fig 5.1
Fig 5.2
Top Tier
Frame
1. Place your Mega Tub Bin on the Top Tier Frame as shown in Fig 5.3. Resupply
and Sharps Bins in the lower portion of the Bin Frame (Fig 5.4). Slide the neck of
the Sharps Bin into the Bin Bracket Opening as shown in Fig 5.5, and then secure
the bin in place.
Mega
Tub Bin
Fig 5.3
Sharps Bin
Resupply Bin Bin Bracket
Fig 5.4
Fig 5.5
D1E Series: Stratus Workstation™
STEP 1 – SECURE TOP TIER FRAME TO WORKSTATION BASE
PAGE 15
D1E manual
5 – WORKSTATION INSTALLATION CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. Refer to Fig 5.7 to review your foot pedal type and see Fig 5.8 for a detailed view of the rheostat running through the floor to the toe of the chair.
Fig 5.7
Fig 5.8
D1E Series: Stratus Workstation™
STEP 1 – LOOSEN SET SCREW AND ADJUST TO DESIRED HEIGHT
PAGE 16
D1E manual
6 – WORKSURFACE HEIGHT ADJUSTMENT
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. Loosen the Height Adjustment Screw (use provided 3/16” allen wrench) on the Workstation Support Post Coupler. Fig 6.0 2. Raise or lower the worksurface in 1” increments by lining up the holes on the workstation support post to the workstation wheel base. 3. Tighten the adjustment screw to the desired height. 4. Refer to fig 6.1 for approximate height dimension of raised surface.
Fig 6.0
Height Adjustment Screw
1” preset height adjustment slots
Fig 6.1
D1E Series: Stratus Workstation™
STEP 1 – REMOVE ACCESS PANEL AND QUICK DISCONNECT COVER
STEP 2 – MAKING THE UMBILICAL CONNECTIONS
PAGE 17
D1E manual
7 – UMBILICAL INSTALLATION
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. Remove the Quick Connect Cover (Fig 7.1) to get access to
the Connections and Hose Clamp.
2. The Access Panel can also be removed for maintenance
and final hose / wire hookups. Lift the panel upwards and then
remove the access panel.
3. Connection schematic is on the back of the access panel
cover.
Quick Connect Cover
Access Panel *Note: Using EP C4 cabinet as reference only.
1. All of the utilities required by your Workstation are supplied via the Umbilical Tube. Installation simply involves plugging in tubing and electrical connectors.
2. Refer to Fig 7.2 to get familiar with the tubing and electrical connections (some options shown, and may not be to the configuration of your Workstation.).
3. Be Careful not to cut or damage any of the tubes and wires inside the umbilical tube.
Fig 7.2
USB Connection Optional
Suction Hose
9 Pin Connector Optional Tubing
Connector
Power Cord Optional
Umbilical Tube
D1E Series: Stratus Workstation™
STEP 3 – CONNECTING THE 9 PIN AND TUBING CONNECTORS
STEP 4 – CONNECTING THE USB, POWER, AND SUCTION HOSE CONNECTIONS
PAGE 18
D1E manual
7 – UMBILICAL INSTALLATION CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. Plug in 9 Pin Power Connector and Tubing
Connector as shown in Fig 7.3.
2. For proper orientation the 9 Pin Power
Connector wires black, yellow, and red should
be on top.
3. To plug and secure the Tubing Connector
move lever clockwise to install or remove.
Move counter clockwise to lock in place.
9 Pin Power
Connector
Tubing
Connector
Fig 7.3
1. Refer to Fig 7.4 for connections. 2. Plug suction hose onto copper tube. 3. Run USB cord through hole and make appropriate connections. 4. Run Power cord through hole and make appropriate connections.
Fig 7.4
USB Cord
Power Cord
Suction Hose
Copper Tube
D1E Series: Stratus Workstation™
STEP 5 – SECURING UMBILICAL HOSE
STEP 6 – WIRING AND TUBING CONNECTIONS
PAGE 19
D1E manual
7 – UMBILICAL INSTALLATION CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
1. Securely attach umbilical hose to chassis with hose clamp. See Fig 7.5. When in place rotate the screw body of the Hose clamp fully to the right (or left) to prevent cover interference. 2. Hook cover on tab at top and fasten with the 2 thumb screws on bottom corners. 3. To make your final wiring and tubing
connections you will need to remove the Utility
panel to access the connections.
Umbilical Cover
Thumb Screw (2)
Hose Clamp
Umbilical Hose Umbilical Chassis
Fig 7.5
1. To make your wiring and
tubing connections you will need
to remove the Utility panel (refer
back to fig 7.1).
2. Please be sure to have your
licensed contractor or installer
follow Fig 7.6 for proper tubing
and wiring connections. Wiring
and tubing may differ depending
on options purchased.
Configuration shown with all
standard options.
Fig 7.6
EP WORKSTATION POWER CHANNEL FACEPLATE
Optional Bien Air MX II (refer to Bien Air documentation)
Standard (Non-Electric) Faceplate
D1E Series: Stratus Workstation™
PAGE 20
D1E manual Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
8 – POWER CHANNEL MAINTENANCE
Handpiece Coolant Air Spray Air On/Off (normally left in On position)
Water Source
Selector
Left Handpiece
Coolant Flow
Left Handpiece
Automatic Holder
Optional Middle Handpiece
Automatic Holder
Right Handpiece
Automatic Holder
Right Handpiece
Coolant Flow
Master On/Off
Handpiece Coolant Water
On/Off
Bien Air Control Pad/Display (Please refer to Bien Air Literature)
Handpiece Coolant Spray Air On/Off
(normally left in On position)
Water Source
Selector
Left Handpiece
Coolant Flow
Left Handpiece
Automatic Holder Right Handpiece
Automatic Holder
Optional Middle Handpiece
Automatic Holder
Right Handpiece
Coolant Flow
Master On/Off
Handpiece Coolant
Water On/Off
FACEPLATE FUNCTIONS / DEVICE INFORMATION The following table describes the functions on the faceplates.
FUNCTION DESCRIPTION
Chip Air
Turns air on/off to the air jets at the base of the burrs on all
handpieces. This is left on except for certain surgical procedures.
Note: When switch is off, water coolant will not be atomized!
Water Source Selector
Selects the source of water directed to the handpieces and all other devices using water. Set it to Bottle to draw water from the attached bottle. Set it to Line to draw water from the connected water source.
(Only if city water option has been purchased)
Left-Handpiece Coolant Flow
Adjusts the amount of coolant water that flows through the left
handpiece. Turn the knob counterclockwise to increase the flow and clockwise to decrease the flow.
Master On/Off
Turns on and off the master power. Turning it On activates air and
water pressure. The dental workstations are connected to the dental air supply (sold and installed by others) by way of a
combination master regulator and shut off valve. The master shut off and regulator is activated by the on/off switch, so labeled, on the
face plate. There are regulator adjustment pressures on the label attached to the regulator and in the installation manual.
CAUTION: Turn the master switch Off when unit is not in use to
prevent accidental water flow.
Handpiece Coolant On/Off
Turns on or off the flow of coolant water to the handpiece. This
control must be On to allow water to flow to either of the handpiece Coolant Flow controls.
D1E Series: Stratus Workstation™
PAGE 21
D1E manual
8 – POWER CHANNEL MAINTENANCE CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
Standard Chassis (Rear View)
D1E Series: Stratus Workstation™
PAGE 22
D1E manual
8 – POWER CHANNEL MAINTENANCE CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487
Bottle
Connection
(120 Volt)
Outlet
USB
Optional Scaler
Connection (Power)
Optional Scaler Connection
(Foot Control)
1/4 Water (35-40 PSI)
Auxillary Connection
(Color Coded Blue Ring)
1/4 Air (80-83
PSI) Auxillary
Connection
(Color Coded
Yellow Ring)
EP WORKSTATION POWER CHANNEL CHASSIS Bottom Perspective
D1E Series: Stratus Workstation™
PAGE 23
8 – POWER CHANNEL MAINTENANCE CONT’D
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487 D1E manual
Serial
Number Tag Optional
Cure Light
Connection
Water Bottle
Base/Connector
Umbilical
Outlet
Handpiece
Drive Air
Adjustment
Screws
Muffler/Oil
Collector
Vacuum Canister
Outlets (2 HVE/SVE)
Handpiece
Connectors (2-3)
Handpiece
Hanger Valves
Channel Pivot
Bushing
WATERLINE DISINFECTION RECOMMENDATIONS
The bottle mounted under the rear of the power channel is a 2.0L (2000ml) dedicated water bottle. Its use is selected via the bottle position on the bottle/line switch mounted on the power channel face. The line position on the bottle/line switch selects water from your piped water supply.
Doctors using dedicated water systems commonly run distilled water or treated bottled water (for
example BluTab; EPA registration # 84020-1) through this system each time the bottle is filled. The BluTab is added to an empty self-contained water bottle before each filling.
The waterlines do not need to be flushed with the BluTab disinfectant. The BluTab is specially
formulated to be continuously present in the waterlines and to keep lines clean. Weekly shock treatments are not necessary. Purging water lines at the end of a work day is not necessary.Check water lines periodically for deterioration and replace if necessary prior to patient use. If water line tubing needs to be replaced, please contact Ergonomic Products.
Note: Ergonomic Products, Inc. does not assume responsibility for your waterline treatment decisions. Please consult with the ADA and CDC recommendations. CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008; Centers for Disease Control and Prevention. Guidelines for Infection Control in Dental Health-Care Settings— 2003. MMWR 2003;52 (No. RR-17): [inclusive page numbers]. FDA Processing/Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling DRAFT GUIDANCE May 2, 2011.
D1E Series: Stratus Workstation™
8 – POWER CHANNEL MAINTENANCE CONT’D
PAGE 24
D1E Series: Stratus Workstation™
VACUUM USE AND MAINTENANCE
MUFFLER AND OIL COLLECTOR MAINTENANCE
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487 D1E manual
8 – POWER CHANNEL MAINTENANCE CONT’D
CAUTION: Always wear gloves when servicing dental workstations. System description Your workstation is equipped with a 5/8” main vacuum tube connecting to a 3-port vacuum canister (2 HVE and 1 Saliva Ejector) mounted in the forward part of the power channel, with the lid protruding through the cover for easy access. Units come standard with one saliva ejector valve and one HVE valve. Both valves are a quick-disconnect and autoclaveble type. Tips for both valves are industry standard and you can order these from your dental equipment supplier. System maintenance Vacuum Canister Check the vacuum canister and screen (part #409-155) weekly. Replace them as soon as lower than normal vacuum is detected. To facilitate cap removal, turn off the vacuum pump before servicing. Call Ergonomic Products, Inc. at 1-800-ERGO-4-US to order new components. Valves Valves can be autoclaved after each use or wiped down using any of the commercially available disinfecting wipes. Daily, draw clean water through the valves while working the valve handle to help prevent the buildup of debris. Brush the internal bore once a week with a stiff brush of proper size. Disassemble valves periodically (2-3 months) to clean internal parts and lubricate the O-rings.
A combination muffler and oil collector quiets the spent drive and traps excess handpiece lubrication. Unscrew the lower portion of the canister to access the piece of gauze that acts as an absorbing pad. Check the gauze every couple of weeks and replace it as necessary.
PAGE 25
D1E Series: Stratus Workstation™
GENERAL GUIDELINES
CLEANING
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487 D1E manual
9 – CLEANING AND DISINFECTING
After treatment of each patient and at the completion of daily work activities, countertops and dental unit surfaces that might have been contaminated with patient material or when the surface is contaminated with biological material must be cleaned with disposable toweling (for example PDI Super Sani Cloth) and water as necessary. Then disinfect surfaces with a suitable chemical germicide (for example DisCide Ultra Disinfectant Spray). The CDC recommends using a chemical germicide registered with the EPA as a “hospital disinfectant” and labeled for “tuberculocidal” (i.e., mycrobactericidal) activity to disinfect surfaces that have been soiled with patient material. These intermediate-level disinfectants include phenolics, iodophors, and chlorine-containing compounds. Because mycobacteria are among the most resistant groups of microorganisms, germicides effective against mycobacteria should be effective against many other bacterial and viral pathogens. Low-level disinfectants—EPA-registered “hospital disinfectants” that are not labeled for "tuberculocidal" activity (e.g., quaternary ammonium compounds)—are appropriate for general housekeeping purposes such as cleaning floors, walls, and other housekeeping surfaces. The CDC does not recommend using intermediate- and low-level disinfectants to reprocess critical or semicritical dental instruments. Note: CDC Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008; Centers for Disease Control and Prevention. Guidelines for Infection Control in Dental Health-Care Settings— 2003. MMWR 2003;52 (No. RR-17): [inclusive page numbers]. FDA Processing/Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling DRAFT GUIDANCE May 2, 2011.
Metal Components Use mild detergent and water or any of the commercially available sprays, such as 409, Fantastic, or others, with a soft cloth or sponge. DO NOT USE ABRASIVES as these will permanently scratch the finish. Plastic, Rubber and Painted Surfaces Use mild detergent and water or any of the commercially available sprays, such as 409, Fantastic, or others, with a soft cloth or sponge. DO NOT USE ABRASIVES as these will permanently scratch the finish. Corian Your Corian surfaces are delivered with a matte/satin finish and any of the above cleaners are acceptable. Minor surface blemishes can be brought back to a like-new finish with the use of a mild abrasive cleaner such as Comet on their own or in conjunction with a green or white Scotch-Brite Pad. Dried composites can be scraped off using a single-edged razor blade or equivalent, being cautious not to dig into the surface. If the surface becomes too scarred to be renewed with the above procedures, a resurfacing can be done. Please contact us or any Corian-certified installer for the correct procedure. The FDA recommends that Items contaminated with blood or body fluids, which might contain bloodborne pathogens, must receive intermediate level disinfection with a product having an EPA-registered claim for activity against hepatitis B after cleaning.
PAGE 26
D1E Series: Stratus Workstation™
DISINFECTING
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487 D1E manual
CLEANING AND DISINFECTING CONT’D
Instruments and Workstation Infection Control in the dental environment is always a high priority for both the user and the patient. It is the responsibility of the practitioner to be familiar with best practices and protocols for disinfecting of instruments and surfaces as recommended by CDC, ADA and OSHA. In addition to the General Guidelines, the CDC recommends general cleaning and disinfecting of clinical contact surfaces, dental unit surfaces, and countertops at the end of daily work activities. Cleaning and disinfection are required if surfaces have become contaminated since their last cleaning. To facilitate daily cleaning, keep treatment areas free of unnecessary equipment and supplies. To disinfect Corian surfaces, use a suitable chemical germicide (for example DisCide Ultra Disinfectant Spray). Dental devices that are connected to the dental water system and that enter the patient’s mouth (for example; handpieces, ultrasonic scalers, or air/water syringes) must be operated to discharge water and air for a minimum of 20–30 seconds after each patient. Most of the surfaces are compatible with commonly used disinfectants, however if discoloration is noticed (especially hoses) it would be advisable to change cleaning products. If using a spray, use sparingly around electrical devices and components.
PAGE 27
D1E Series: Stratus Workstation™
Ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487 D1E manual
10 – WARRANTY INFORMATION
Ergonomic Products offers the following warranty on our products. 5-year limited warranty on all Corian® surfaces* 3-year warranty on all RapidCarts®** 5-year warranty on all EP 3 Series® Patient Chairs*** 3-year warranty on all Workstations® 3-year warranty on all EP Lighting**** 1-year warranty on all cabinetry, laminates and components 1-year warranty on all storage tubs and bins 3rd party components carry the original manufacturer’s warranty:
1-year warranty on scalers
1-year warranty on cure lights
1-year warranty on Ultraleather upholstery
1-year warranty on BienAir Electric Motors * Limited to manufacturer’s defects only ** Excludes powder coated RapidCarts® tops (1 year warranty) *** Excludes upholstery (1 year warranty) **** Excludes bulbs Discontinued parts or components cannot be serviced once the warranty has expired. Additional 3rd party sources may be available. We promise to offer you prompt, inexpensive repairs. Products under warranty will be fixed as quickly as possible and service will be done on site if feasible. If it must be returned to our technical center, it will be returned to you without additional shipping charges. If the time needed to repair it will affect your practice schedule, we will try to provide a loaner so as to not interrupt your service to your patients. In an emergency, our Doctor Delivery Power Channels® will ship overnight. Should your office damage equipment, due to improper use or inadequate installation or maintenance, we’ll still make sure to fix your problem, promptly and without complaint. The warranty will not apply, nor is there a warranty for fabric damaged by infection control products. We promise to continuously satisfy you with our products and services. We want to hear from you and help you improve your practice. Sincerely, The Staff at Ergonomic Products, Inc. 1-866-ERGO-4-US