Download - Equipment for Engineering Education & Research BERNOULLI’S ...solution.com.my/pdf/FM24(A4).pdf · circumstances to which Bernoulli’s Theorem may be applied as well as in other

Transcript
Page 1: Equipment for Engineering Education & Research BERNOULLI’S ...solution.com.my/pdf/FM24(A4).pdf · circumstances to which Bernoulli’s Theorem may be applied as well as in other

SOLTEQ®

BERNOULLI’S THEOREM

DEMONSTRATION

MODEL: FM 24

THIS Bernoulli’s Theorem Demonstration (Model: FM 24) apparatus consists of a classical Venturi

made of clear acrylic. A series of wall tappings allow measurement of the static pressure distribution

along the converging duct, while a total head tube is provided to traverse along the centre line of the

test section. These tappings are connected to a manometer bank incorporating a manifold with air bleed valve.

This unit has been designed to be used with a

Hydraulics Bench for students to study the

characteristics of flow through both converging and

diverging sections. During the experiment, water is

fed through a hose connector and students may control

the flowrate of the water by adjusting a flow regulator

valve at the outlet of the test section.

The venturi can be demonstrated as a means of flow

measurement and the discharge coefficient can be

determined.

This test section can be used to demonstrate those

circumstances to which Bernoulli’s Theorem may be

applied as well as in other circumstances where the

theorem is not sufficient to describe the fluid behaviour.

EXPERIMENTAL CAPABILITIES

♦ Bernoulli’s Theorem and its limitations

♦ Measurements of the static and total head

distribution along a Venturi tube

♦ Meter coefficient at various flow rates

Equipment for Engineering Education & Research

Page 2: Equipment for Engineering Education & Research BERNOULLI’S ...solution.com.my/pdf/FM24(A4).pdf · circumstances to which Bernoulli’s Theorem may be applied as well as in other

SOLTEQ

TYPICAL EXPERIMENT RESULT

Actual Flow Rate Versus Ideal Flow Rate

0

5

10

15

20

25

0 5 10 15 20 25

Ideal Flow Rate, Qi (LPM)

Act

ual

Flo

w R

ate,

Qa

(LP

M)

SPECIFICATIONS

Manometer : 0 to 300 mm, 8 tubes

Venturi : Throat dia.: 16 mm

Upstream dia.: 26 mm

Upstream taper: 14°

Downstream taper: 21°

Flowmeter : max. 20 LPM

REQUIREMENTS

Hydraulics Bench ( FM 110 )

SOLTEQ®Equipment for Engineering Education & Research

Page 3: Equipment for Engineering Education & Research BERNOULLI’S ...solution.com.my/pdf/FM24(A4).pdf · circumstances to which Bernoulli’s Theorem may be applied as well as in other

Our range of teaching equipment can be complemented with our

SOLDAS and SOLCAL software.

SOFTWARE & E - LEARNING

SOLDAS® - Supervisory Control & Data Acquisition

- Data Logging

- Signal Analysis

- Process Control

- Real-Time Display

- Tabulated Results

- Graph of Experimental Results

SOLCAL® - Computer Aided Learning

- Multimedia Features

- Interactive

- Graphic Simulation

- Experiment Result Samples

- Full Experiment Manuals

SOLTEQ®

Contact us for a catalog CD

SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)

Sales Office :

No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000Fax. No. : +(603) 80755784

R&D Office :

G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023

Email : [email protected] site : http//www.solution.com.my/

AGENT:

Equipment for Engineering Education & Research

BUATAN MALAYSIA

MSC- StatusCompany