A L T R A I N D U S T R I A L M O T I O N
Electric Actuatorsand Actuator Controls
Measurements in Imperial and Metric Units
ARTEN Freios e Embreagens - Fone: 11 5594-8333
Warner Linear is dedicated to designing and manufacturing the broadest selection of rugged service electromechanical actuators that serve the…
Our manufacturing facilities are located in Belvidere, IL (USA) and Angers, France.
Warner Linear offers a full line of standard electric actuators, each specifically designed to meet the needs of
All are engineered for maintenance-free, long-life service, providing maximum value for our customers. Our electric actuators are engineered and produced using quality components from ISO registered key suppliers.
Warner Linear provides a full line of actuator controls well suited for a broad range of application needs. They range from simple to use switch box controls for basic extend/retract function, to state-of-the-art microprocessor based digital electronic controls using SMT design and manufacturing processes.
light-duty, general-duty,or rugged-duty applications.
Food & Beverage
Mobile Off-Highway
Medical
Packaging
Turf & Garden
Material Handling &
Marine Industries
worldwide
ARTEN Freios e Embreagens - Fone: 11 5594-8333
1P-1581-WL 2/16....6
Warner Linear…Customer Focused, Quality DrivenProducts designed and manufactured for reliable, long-lasting performance
Quality ProcessesWarner Linear is dedicated to designing and manufacturing “best-in-class” electromechanical actuators and controls.
We subscribe to a standard of quality derived from Altra's operational excellence initiative, a comprehensive business management approach designed to drive world-class performance.
Our quality starts in product design. It is demonstrated in the attention given to design details and the refinement of prototypes. It is apparent in our fast response to requests for quotes, and our strict adherence to deadlines in every stage of the work flow.
Design and TestingOur application engineers and design specialists work closely with our customers to define both lab and field testing requirements.
Our solid model design capabilities, computer assisted testing, and manufacturing floor pre-shipment cycle test, all provide assurance that your Warner Linear actuators will meet or exceed your expectations (for application and technical service call 1-800-825-9050).
Our linear actuator testing capabilities include dual load life cycling stands, low and high pressure washdown test tanks, lift test stands and thermal shock submersion. Our test service providers add material analysis, noise and vibration evaluation capabilities.
Custom SolutionsWe recognize how critical our actuators are to the overall performance of your equipment. Working closely with your engineering and development staff, we strive for an early understanding of how you want your linear actuator to perform.
Building a direct communication line from our engineer to your engineer provides a number of significant benefits.
• A teaming of creative resources
• Joint understanding of our actuator capabilities and howthey can be tailored to your application.
• An understanding of the lowest cost solution to meet youractuator requirements.
• Providing a complete solution that includes controls asrequired.
Please contact our knowledgeable staff with all of your Linear Product needs.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
Warner Linear offers a full line of standard electric actuators, each specifically designed to meet the needs of light-duty, general-duty, or rugged-duty applications. All are engineered for maintenance-free, long-life service, providing maximum value for our customers.
Linear actuators to meet your specific requirements
ContentsApplications/ Performance Features ............................ 4-5
M-Track Design Features ...................6
M-Track Configurator .........................7
M-Track 1 ....................... 8-12
S-Track ......................... 13-18
I-Track ........................... 19-21
B-Track Design Features .................22
B-Track Configurator .......................23
B-Track K2vl ................ 24-27
B-Track K2 ................... 28-31
B-Track K2ac ................ 32-35
B-Track K2x ................. 36-39
B-Track K2xac .............. 40-43
Custom Actuators ....... 44-54
Performance Features ..............................55
Power Supply/ Control/Accessory Selection Guide ..................56
Simple Switch Box Controls .......................57
M-Track Power Supply .....................58
K2/K2x Power Supply ............... 59-60
Switch Only Units SO ..............................61
P1.x Electronic Stroke Limit Control ..........62
Controls – BTc P1-DC .................... 63-64
EP1.x Electronic Stroke Limit Control ..........65
Controls – PQS ................................ 66-67
Controls – BTc P2-DC ..........................68
Controls – BTc RP .................................69
Controls – Wireless ..............................70
General Mounting Information .........................71
Glossary ........................ 72-73
Application Data Form ...........................76
QUICK SELECTION GUIDELight Duty General Duty
M-Track 1Compact, completely self-contained and sealed to allow for use in small spaces without sacrificing power or capability.
S-Track & Programmable S-TrackIntended for general duty applications with need for controllability and quieter operation.
I-Track Unique inline actuator with power-off release feature and designed to fit in limited space applications for loads up to 200 lbs. (890 N).
IP69K Static IP65 Dynamic
IP69K StaticIP65 Dynamic
IP69K StaticIP66 Dynamic
Drive Type: Acme Screw
Drive Type: Acme Screw
Drive Type: Ball Screw
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 25 @ 1.75 (111@45) 50 @ 0.80 (222@20)100 @ 0.45 (445@11)165 @ 0.25 (734@6)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 125 @ 1.0 (556 @ 25)175 @ 0.75 (778 @ 18)200 @ 0.50 (890 @ 12) 225 @ 0.62 (1001 @ 15)300 @ 0.33 (1334 @ 8)400 @ 0.25 (1779 @ 6)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 200 @ 1.1 (890 @ 26)
Stand. Stroke Length in. (mm) 2, 4, 6, 8, 10, 12 (50, 100, 150, 200, 254, 300)
Stand. Stroke Length in. (mm) 2 to 12 in 2” increments (50 to 300 in 50 mm increments)
Stand. Stroke Length in. (mm) 2 to 12 in 2” increments (50 to 300 in 50 mm increments)
Input Voltage (vdc): 12, 24
Input Voltage (vdc): 12, 24
Input Voltage (vdc): 12, 24
Typical Applications:• Throttle Control• Air Vent Opening• Remote Window Operation• Remote Mirror Positioning• Gate Opening• Shutter Control
Typical Applications:• Indoor Office Equipment• Medical• Deck Lifts• Gate Openers
Typical Applications:• Throttle controls• Hydraulic flow controls• Bus Door Operator• Hatch lift applications• Handicap Van Lifts• Engine Controls• Emergency Door (lock and unlock via
VDC)
Pg 6-12 Pg 13-18 Pg 19-21
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
ARTEN Freios e Embreagens - Fone: 11 5594-8333
General Duty Rugged Duty
B-Track K2vl
Intended for severe servicerequirements and loads upto 600 lbs. (2669 N) Lowestpriced model in the B-Trackfamily.
B-Track K2Uses a patented straightline load transfer offeringhigh load capability in asmall package size. Bronzeor Delrin® nut options highimpact load applications upto 1,500 lbs. (6672 N).
B-Track K2x
Completely sealed, designedfor tough, high loadapplications. Able to performin harsh environmentsproviding years of trouble-free service.
B-Track K2ac
Uses a patented straight lineload transfer offering highload capability in a smallpackage size. Bronze orDelrin® nut options for highimpact load applications upto 1,100 lbs. (4893 N).
B-Track K2xac
Completely sealed, designedfor tough, high loadapplications. Able to performin harsh environmentsproviding years of trouble-free service.
IP69K StaticIP66 Dynamic
IP69K StaticIP65 Dynamic
IP69K StaticIP65 Dynamic
IP54 IP54
Drive Type: Hybrid Acme
Drive Type: Hybrid Acme
Drive Type: Ball Screw & Ball Nut
Drive Type: Hybrid Acme
Drive Type: Ball Screw & Ball Nut
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 200 @ 2.0 (890 @ 50) 300 @ 1.0 (1334 @ 25)600 @ 0.5 (2669 @ 12)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 300 @ 2.0 (1334 @ 50) 600 @ 1.0 (2669 @ 25)1200 @ 0.5 (5338 @ 12)1500 @ 0.35 (6672 @ 9)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 600 @ 2.0 (2669 @ 50) 1200 @ 1.0 (5338 @ 25)2200 @ 0.5 (9786 @ 12)2800 @ 0.25 (12455 @ 6)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 500 @ 1.0 (2224 @ 25) 750 @ 0.50 (3336 @ 12)1100 @ 0.33 (4893 @ 0.4)
Load Capacity & Speed lbs. @ in./sec. (N@mm/sec) 500 @ 2.0 (2224 @ 50) 1000 @ 1.0 (4448 @ 25)1500 @ 0.5 (6672 @ 12)2000 @ 0.33 (8900 @ 8)
Stand. Stroke Length in. (mm) 2 to 12 in 2” increments (50 to 300 in 50 mm increments)
Stand. Stroke Length in. (mm) 2 to 24 in 2” increments (50 to 600 in 50 mm increments)
Stand. Stroke Length in. (mm) 2 to 24 in 2” increments (50 to 600 in 50 mm increments)
Stand. Stroke Length in. (mm) 4 to 24 in 2” increments(100 to 600 in 50 mm increments)
Stand. Stroke Length in. (mm) 4 to 24 in 2” increments(100 to 600 in 50 mm increments)
Input Voltage (vdc): 12, 24
Input Voltage (vdc): 12, 24, 36, 48, 90
Input Voltage (vdc): 12, 24, 36, 48, 90
Input Voltage (vac): 115, 230
Input Voltage (vac): 115, 230
Typical Applications:• Fertilizer Gate Control• Mower Decks• Gate Openers• Scooter & Cycle Lifts• Pull Behind Implement Lifts
Typical Applications:• Residential Mower Decks• Gate & Valve Operation• Snow Blowers• Spouts & Chutes• Engine Lifts• Tables• Wagon Lifts• Combine Concaves
Typical Applications:• Paving Outriggers• Commercial Mower Decks• Spray Booms• ATV Dump Box Lifts• Boat Engine Lifts• Hydraulic Cylinder
Replacement• Construction Equipment
Typical Applications:• Engine Lifts• Tables• Indoor Applications• Machine Tools• Egg Rotation
Typical Applications:• Indoor Applications• Machine Tools• HVAC• Hood Lifts• Tables
Pg 24-27 Pg 28-31 Pg 36-39 Pg 32-35 Pg 40-43
Basic controls and digital electronic options• Adjustable stroke limits• Fixed electronic stroke limits –
ESL• QS Quick Stop bi-directional
current limit control• Position feedback options –
potentiometer or digital outputs
Microprocessor based controls (available for special needs)
• Signal Follower Function• Programming pendant• Adjustable position and current
limit options• Remote mounting capable
Actuator Controls
Contents Quick Selection Guide
Simple extend/retract switch boxes• SBC-DC• SBC-AC
Pg. 56-70
* *
*UL Certification, consult factory
ARTEN Freios e Embreagens - Fone: 11 5594-8333
4 .....P-1581-WL 2/16
Compact designA Warner Linear actuator with a two inch stroke can provide up to 2800 pounds (12455 N) of force capacity in a compact package.
Maintenance-freeUnits are lubricated for life during assembly. There are no adjustments or maintenance required for units after they have left the factory. Consistent performance is provided for the entire life of the actuator.
Equal capacity in both directionsWarner Linear actuators can push-and-pull or lift-and-lower loads ranging from one pound to over 2800 pounds (12455 N) up to 24 inches (600 millimeters) with equal capacity in both directions of travel.
Efficient operationWarner Linear actuators consist of an electric motor combined with a high efficiency gear train and lead screw. This direct conversion of electrical to mechanical energy results in effective, economic linear movement. Units are completely self-contained and require minimal installation hardware or wiring.
Superb load holding powerWarner Linear actuators operate loads in both tension and compression equally well. They will hold a load stationary without power in either direction. Static load holding capability will always exceed the dynamic load moving capability.
Advantages• No hydraulic pumps, hoses, valves, or leaks
• Holds load when power is off
• Overload clutches prevent damage due to excess weight
• Simple to install and use
• Easily adaptable for positioncontrol
• Integrated sensors provideelectrical position signals
• Golf Cart Height Adjust
• Mower Blade Lift
• Solar Panel Adjust
• 55 Gallon Drum Lift
• Fire Engine Valve Adjust
• Automated Dumpster
• Scissor Lift Table
• Round Baler Cover Lift
• Walk Behind Floor Washer
• Bulldozer Engine Cover
• Air Foil Adjust
• Construction SignPositioning
• Forage Harvester SpoutPositioning
• Combine Spout Positioning
• Adjustable Height WorkTable
• Conveyor Lateral GuidePositioning
• Street Sweeper Bristle Lift
• RV/Bus CompartmentExtension
Dependable Operation
Applications and Performance Features
Warner Linear Actuators are available for a wide variety of applications.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
5P-1581-WL 2/16....6
Rugged and reliableWarner Linear actuators incorporate high strength, high quality components and are designed to assure trouble-free service. Rugged spur gearing, industrial quality synthetic lubricants and high performance motors combine to provide maximum capability and value for the end user. Units are gasketed and sealed for operation in industrial and mobile outdoor applications. Thermal overload switches are included for motor protection; and high performance corrosion protection features are standard.
Energy efficientElectric control provides clean, smooth linear motion without fluids, plumbing or other expensive components. Warner Linear actuators require power only when in motion. No power is required to hold loads stationary.
Lead screw drive systemsWarner Linear actuators use either acme, hybrid rolled, or highly efficient ball bearing screws. Models which use acme or hybrid rolled screws with bronze or plastic nuts will not backdrive when power is off. A bi-directional load holding brake is a standard feature on all ball bearing units and holds loads in position when power is off.
Overload protectionMotors incorporate thermal switches in their windings to shut the actuator motor off in case of overheating or high overcurrent. Reset is automatic after the motor has cooled. A standard overload clutch detects if the load is excessive or reaches end of stroke.
Note: Clutch is not incorporated in M-Track and S-Track due to size constraints.
Fuse Recommendation for All Systems:The fuse should be sized to 135% of full-load steady-state current.
Component Protection and DC Motors:DC motors can produce large voltage and current spikes when powered on or off. Back-to-back Zener diodes across the motor are recommended to help suppress the large spike from affecting other sensitive components in the system. Use a 20V-30V back-to-back Zener for a 12VDC motor and a 30V-40V back-to-back Zener for a 24VDC motor. Consult the factory for further recommendations.
VersatileWith their compact size, Warner Linear actuators can be located in confined areas, and move loads from 0 to 2800 pounds (12455 N). Their static load holding ability ensures that a load will remain in position when power is turned off. Gearing ratios create speeds that range from 0.3 to over 2 inches (7 to 50 millimeters) per second. Standard models are mounted using two parallel pins and require only simple wiring and switches. They are self-contained, lubricated for life, and designed for use where rugged and durable performance is required for almost any lift-and-lower or push-and-pull application.
• Direct drive manual override
• Mounting and end fitting variations
• DC Motor voltage variations
• AC and DC motor options
• Motor lead wire connectors
• End of stroke limit switches – fixed or adjustable
• Position feedback outputs (0-10vdc scaled) – potentiometerand digital
Also available• Basic switch box controls
• Integrated electronic position controls
Acme Screw
Ball Screw
Performance Features
Warner Linear Actuators are built for performance.
Available Customized Features
ARTEN Freios e Embreagens - Fone: 11 5594-8333
6 .....P-1581-WL 2/16
M-Track FeaturesLight Duty Actuators
Integral end of stroke limit switches standard. No clutch required.
Integrated rear clevis for easy pin-to-pin mounting
Thermal overloads in windings protect the motor
Optional potentiometer assures accurate, consistent positioning feedback
Key Features• Compact size• Efficient design• Easy to use and install
Dual quad ring bearing provides double protection and rod support
Lightweight aluminum extension rod
Compact spur gear design allows compact space requirements
Standard ModelsM1
Unique Hi-Load solid thrust ring
Sealed limit switches
IP69K and Temporary ImmersionNeoprene Sealing Boot available upon request. Please see pages 9 & 10 for dimensional information. Consult factory for ordering details.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
7P-1581-WL 2/16....6
M-Track Configurator
How To Select
Step 1 – Determine Load and Stroke length requirementsUse the Quick Selection guide to identify the model that will provide the load capacity and stroke length needed for your application.
Step 2 – Identify motor type and voltageSelect DC motor and motor voltage.
Step 3 – Confirm Speed and Current draw requirementsUsing the charts provided, confirm that unit speed and current draw is appropriate for the intended use.
Step 4 – Confirm the application Duty CycleAt full load capacity, actuators have a 25% duty cycle.
Duty cycle is the amount of on-timeon-time + off-time
A unit that runs for 15 seconds should be off for 45 seconds.
Important Unit Restrictions
Side loading and shock loads must be considered in actuator applications. Side loading and cantilevered mounting should be eliminated through proper machine design. Side loading will dramatically reduce unit life. While actuators can withstand limited shock loads, it is recommended that shock loading be avoided wherever possible. (See General Mounting Information on page 71)
Step 5 – Unit OptionsM-Track units include end-of-travel limit switches as a standardfeature. For positional feedback, a 12K linear membranepotentiometer can be factory installed. The changingpotentiometer value provides unit movement feedback for unitsthat are not visible to the machine operator.
M-Track Configurator
0050 AM1 02–– – – L P
Actuator Model No.
M1 – M-Track 1
Screw Type
A = Acme Screw
Limit Switch Options
L – Limit switches included
Load Capacity
0025 – 25 lbs. (111 N)0050 – 50 lbs. (222 N)0100 – 100 lbs. (445 N)0165 – 165 lbs. (734 N)
Note: Not all load ratings are standard for all units.
Consult unit page for details.
Potentiometer
P – With PotentiometerN – No Potentiometer
D012
Motor Voltage Options
D012– 12 volt DCD024– 24 volt DC Stroke Length
01 – 1 in. (25 mm)02 – 2 in. (50 mm)04 – 4 in. (100 mm)06 – 6 in. (150 mm)08 – 8 in. (200 mm)10 – 10 in.(254 mm)12 – 12 in.(300 mm)
Note: Not all stroke lengths are standard on all units. Consult
unit page for details.
For Protective BootConsult factory for ordering details.
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
ARTEN Freios e Embreagens - Fone: 11 5594-8333
8 .....P-1581-WL 2/16
M-Track 1DC Motor Acme Screw
Up to 165 lb. (734 N) Rated Load Up to 1.75 in. (45 mm)/sec. Travel Speed
M-Track 1 compact units are completely self-contained and sealed toallow use in small spaces without sacrificing power or capability. Theload and length capabilities provide solutions for a diverse range ofintermittent duty applications.
Functionally, M-Track 1 actuators are easily interchanged with comparable size hydraulic or pneumatic cylinders on intermittent duty applications. The actuator provides consistent, repeatable performance even for applications with operating conditions including temperature extremes, high humidity, or significant dust.
Specifications
Features• An Acme Screw drive delivers up
to 165 pounds (734 N) of force at aminimum extension rate of 0.25 inches(6.35 millimeters) per second.
• The anodized aluminum alloy housingresists corrosion and provides protectionfrom dirt, dust and humidity.
• Temperature operating range of–20º F to +150º F (-26º to +65º C).–40º F to +185º F (-40º to +80º C)available.
• Standard stroke lengths of 1, 2, 4, 6, 8,10, 12 inches (50, 100, 150, 200, 254, 300millimeters) are available.
• Internal limit switches automatically shutoff the unit at end of stroke.
• Optional potentiometer can providepositional location feedback.
• IP69K Static, IP65 Dynamic
• Temporary Immersion with protectiveboot (see page 10).
• Rod is non rotating during operation, canbe rotated for mounting purposes.
Typical Applications Light load and short distance applications such as:
• Valve and vent adjustments
• Light weight tilt or lift positioning
• Vise and clamp operations
SpecificationsLoad Capacity 25 lbs. (45 N) 50 lbs. (222 N) 100 lbs. (445 N) 165 lbs. (734 N)
Speed at Full Load 1.75 in. (45 mm)/sec 0.80 in. (20 mm)/sec 0.45 in. (11 mm)/sec 0.25 in. (6 mm)/sec
Input Voltage 12 or 24 volt DC for all models
Static Load Capacity 300 lbs. (135 N) for all models
Stroke Length 1, 2, 4, 6, 8, 10 and 12 in. (50, 100, 150, 200, 254, 300 mm) for all models
Clevis Ends .25 in. (6.4 mm) diameter
Duty Cycle 25% for all models
Operation Temperature Range -20º F to +150º F (-26º to + 65º C) for all models, -40º F to +185º F (-40º C to +80º C) available
Environment IP65 Dynamic, IP69K and Temporary Immersion with Protective Boot
Limit Switch Fixed end of stroke limit switches standard for all units
Potentiometer Linear membrane potentiometer optional on all units
ARTEN Freios e Embreagens - Fone: 11 5594-8333
9P-1581-WL 2/16....6
67
7 6
BEAR LINEAR
SCALE 1:2
SIZE PART NUMBERB
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
M Track Dimensions
M-TRACK OUTLINETWCJRZ 3/17/2014
3/17/2014
CREATEDTuesday, June 26, 2007 8:32:43 AM
5 4 3 2 1
12345
1.47[ 37.4 ]
1.30[ 33 ]
Ø 1.500[ 38.10 ]
4.18[ 106.2 ]
.38[ 9.5 ]
.65[ 16.4 ]
.33[ 8.3 ]
Ø .785 - .002+.000
19.94 - 0.0510
.36[ 9.1 ]
Ø .259.253
6.586.43
[ 7.7 ].30
2X
6.5796.426
Ø .259.253
2.05[ 52.1 ]2.89
[ 73.3 ]
.75[ 19.1 ]
1.50[ 38.2 ]
1.16[ 29.5 ]
14.012.0
355304
[ ] [ ]
[ ]
[ ]
M-Track 1
• Stroke and its tolerance are based on a unit with noattached load operating at rated voltage +/-.5VDC, 70° Fcontrolled temperature environment. Note normal wear,temperature changes and load variations all affect the stroketolerance. If stroke tolerance is critical it is advisable that theselected unit be evaluated for performance in the specificapplication.
• The retract pin to pin dimension and its tolerance arebased on a unit with no attached load operating at ratedvoltage +/-.5VDC, 70° F controlled temperature environment.Note normal unit wear, temperature changes and loadvariations all affect the stroke tolerance. If the retract pin topin dimension is critical it is advisable that the selected unitbe evaluated for performance in the specific application.
• Rotation of the extension tube is allowed up to one full turnto aid mounting. Rotate rod clockwise until it is fully seated inthe unit. Rotate counterclockwise no more than one full turnto align clevis pins.
• Mounting points in the application must allow the actuatorto reach full-extend and full-retract to ensure the internal limit switches are activated. If this is not possible another method for shutting off the actuator must be employed.
• If the actuator encounters an obstruction at mid-strokeand is not allowed to reach the internal limit switches the actuator will stall. An internal thermal circuit breaker is designed to protect the motor from damage during stalling and/or overheating due to exceeding duty cycle. If tripped it will self reset after a short period of time. The thermal is rated to protect the motor in the event of a stall condition. It is not designed to protect any other device in the circuit.
• Warner Linear recommends an externally mounted fuseof 6 AMPs max for 12VDC and 3 AMPs max for 24VDCcircuit protection. Anything connected to the actuator mustbe sized to withstand the actuator’s power consumption orindependently isolated from the circuit.
Dimensions
M-TrackStroke
in. mm in. mm in. mm in. mm in. mm in. mm
2 50 4 100 6 150 8 200 10 254 12 300
A (w/o POT) 6.22 158.0 8.23 209.0 10.24 260.1 12.24 310.9 14.25 362.0 16.26 413.0
A (POT) 7.55 191.8 9.57 243.1 11.57 293.9 13.58 344.9 15.58 395.7 17.58 446.5
Note: Special lengths available; metric stroke length for reference only
DELPHI PACKARD MALE CONNECTOR8911773 BODY6294511 TERMINALS (2)CONNECT (+) TO & (-) TO BLACKTO EXTEND ACTUATOR
NO CONNECTOR ON POTENTIOMETER UNIT
["A"]"A" RETRACTED
STROKE TOLERANCEIS +/-.078 [1.98]
THRUTHRU
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
10 .....P-1581-WL 2/16
Dimensions
M-Trackwith Boot LN/LP
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
2 50 4 100 6 150 8 200 10 254 12 300
A 9.48 241 9.48 241 11.48 292 13.48 342 15.48 393 17.48 444
B 11.48 292 13.48 342 17.48 444 21.48 546 25.48 647 29.48 749
Note: Special lengths available
Features• All features as M-Track
• Protective Boot for temporary immersion
Typical Applications Light load and short distance applications such as:
• UTV differential locks
• Transmission Shifting
M-Track 1 with Protective BootFor Rubber Bellow Application
19.1.75
38.21.50
52.22.05
73.32.89 ACTUATORBODY HEIGHT
652.56
7.7.30
38.11.50
106.24.18
9.5.38
8.3.33
2X
6.506.35
.256
.250
33
1.30
19.9.79
16.4.65
9.5.38
45.71.80
ALL DIMENSIONS ARE NOMINALUNLESS OTHERWISE SPECIFIED
NOTE:2" STROKE LENGTH UNAVAILABLE WITH A RUBBER BOOTALTERNATE METHOD IS TO USE 4" STROKE WITH 2" LIMITS
M TRACK FOR RUBBERBELLOW APPLICATION
SPECIAL LENGTHS AVAILABLE
D
C
B
A
B
C
D
678
8 7 6
BEAR LINEAR
SCALE 1:2
SIZE PART NUMBER
BREV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
M Track Catalog Representation
M-TRACK BOOT OUTLINE
TWCJRZ 10/9/2014
NW
10/9/2014
CREATEDTuesday, June 26, 2007 8:32:43 AM
5 4 3 2 1
12345
A
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
NOTE: 2" Stroke Length unavailable with a Rubber Boot.Alternate method is to use 4" Stroke with 2" Limits
ACTUATOR BODY WIDTH
[73.3] 2.89 ACTUATOR BODY HEIGHT
BOOT(APPROX.)
ROD
THRUBOTH SIDES
BREATHER TUBE USEDFOR PROPER VENTING(APPROX.)
"A" RETRACTED"B" EXTENDED
ARTEN Freios e Embreagens - Fone: 11 5594-8333
11P-1581-WL 2/16....6
M-Track 1 Speed Current Draw
Performance Graphs ImperialMeasurements*
M1-D012-0025
M1-D012-0050
M1-D012-0100
M1-D012-0165
M1-D024-0025
M1-D024-0050
M1-D024-0100
M1-D024-0165
1.56
1.59
1.62
1.65
1.68
1.71
1.74
0.75
1
1.25
1.5
1.75
2
0 5 10 15 20 25
M1-D012-0025 Nominal Performance
Current Draw Speed
1.56
1.59
1.62
1.65
1.68
1.71
1.74
0.375
0.5
0.625
0.75
0.875
1
0 5 10 15 20 25
M1-D024-0025 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.97
0.975
0.98
0.985
0.99
0.995
1
1.005
0
0.5
1
1.5
2
2.5
0 10 20 30 40 50
M1-D012-0050 Nominal Performance
Current Draw Speed
0.97
0.975
0.98
0.985
0.99
0.995
1
1.005
0
0.25
0.5
0.75
1
1.25
0 10 20 30 40 50
M1-D024-0050 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.5
0.54
0.58
0.62
0.66
0.7
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 20 40 60 80 100
M1-D012-0100 Nominal Performance
Current Draw Speed
0.5
0.54
0.58
0.62
0.66
0.7
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
0 20 40 60 80 100
M1-D024-0100 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.37
0.38
0.39
0.4
0.41
0.42
0.43
0.5
1
1.5
2
2.5
3
3.5
0 15 30 45 60 75 90 105 120 135 150 165
M1-D012-0165 Nominal Performance
Current Draw Speed
0.37
0.38
0.39
0.4
0.41
0.42
0.43
0.25
0.5
0.75
1
1.25
1.5
1.75
0 15 30 45 60 75 90 105 120 135 150 165
M1-D024-0165 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
Load Capacity 50 lbs.
Load Capacity 165 lbs.
Load Capacity 25 lbs.
Load Capacity 100 lbs.
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 12.
For Metric Measurements, see page 12.
For Metric Measurements, see page 12.
For Metric Measurements, see page 12.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
12 .....P-1581-WL 2/16
1.56
1.59
1.62
1.65
1.68
1.71
1.74
0.75
1
1.25
1.5
1.75
2
0 5 10 15 20 25
M1-D012-0025 Nominal Performance
Current Draw Speed
1.56
1.59
1.62
1.65
1.68
1.71
1.74
0.375
0.5
0.625
0.75
0.875
1
0 5 10 15 20 25
M1-D024-0025 Nominal Performance
Current Draw Speed
0.97
0.975
0.98
0.985
0.99
0.995
1
1.005
0
0.5
1
1.5
2
2.5
0 10 20 30 40 50
M1-D012-0050 Nominal Performance
Current Draw Speed
0.97
0.975
0.98
0.985
0.99
0.995
1
1.005
0
0.25
0.5
0.75
1
1.25
0 10 20 30 40 50
M1-D024-0050 Nominal Performance
Current Draw Speed
M-Track 1
M1-D012-0025
M1-D012-0050
M1-D012-0165
M1-D024-0025
M1-D024-0050
M1-D012-0100 M1-D024-0100
M1-D024-0165
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PSSp
eed
- M
MPS
Load - N
Load - N
Load - N
Load - N
0.5
0.54
0.58
0.62
0.66
0.7
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 20 40 60 80 100
M1-D012-0100 Nominal Performance
Current Draw Speed
0.5
0.54
0.58
0.62
0.66
0.7
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
0 20 40 60 80 100
M1-D024-0100 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
0.37
0.38
0.39
0.4
0.41
0.42
0.43
0.5
1
1.5
2
2.5
3
3.5
0 15 30 45 60 75 90 105 120 135 150 165
M1-D012-0165 Nominal Performance
Current Draw Speed
0.37
0.38
0.39
0.4
0.41
0.42
0.43
0.25
0.5
0.75
1
1.25
1.5
1.75
0 15 30 45 60 75 90 105 120 135 150 165
M1-D024-0165 Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
Load Capacity 111 N
Load Capacity 223 N
Load Capacity 445 N
Load Capacity 734 N
Performance Graphs Metric SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 11.
For Imperial Measurements, see page 11.
For Imperial Measurements, see page 11.
For Imperial Measurements, see page 11.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
13P-1581-WL 2/16....6
S-Track and Programmable S-Track Features
Up to 400 lb. (1779 N) Rated Load Up to 1 in. (25.4 mm)/sec. Travel Speed
New S-Track electric actuators are designed for better control and quieter operation in general duty applications including medical, industrial, turf & garden and recreational vehicles.
S-Track Adjustable ControlThe control functions the same as the basic control, but also has the capability to stop at up to four different positions. The stop positions are programmed by using a membrane keypad mounted to the actuator. The main benefit is to be able to change the end limit stop locations and two additional stops if needed.
S-Track Basic ControlThe control allows for 12 or 24 VDC switched power operation of the S-Track actuator by turning power off to the motor automatically when the internal end limits are reached.
SpecificationsG07 G11 G14 G17 G26 G35
Load Capacity125 lbs. (556 N)
175 lbs. (778 N)
200 lbs. (890 N)
225 lbs. (1001 N)
300 lbs. (1334 N)
400 lbs. (1779 N)
Speed at Full Load1.0 in.
(25 mm)/sec
0.75 in. (18 mm)/
sec
0.62 in. (15 mm)/
sec
0.50 in. (12 mm)/
sec
0.33 in. (8 mm)/
sec
0.25 in. (6 mm)/
sec
Input Voltage 12 or 24 volt DC for all models
Static Load Capacity 700 lbs. (315 kg) for all models
Stroke Length2, 4, 6, 8, 10 and 12 in. (50, 100, 150, 200, 254, 300 mm)
for all models
Duty Cycle 25% for all models
Operation Temperature Range
-20º F to +150º F (-29º C to + 65º C) for all models,-40º F to +185º F (-40º C to +80º C) Available
Environment IP50 Standard, IP65 Dynamic, IP69K Static Configurable
Acme ScrewFeatures• The end limits are factory set to the maximum
allowable stroke of the actuator.
• The current and temperature of the motorare monitored at all times and power will beremoved from the motor when exceeded toprotect components from failure.
• Several standard input and output featuresthrough the 8-pin molded connector to monitorthe operation of the actuator.
• 0-10 VDC position output follows linearly withthe position of the actuator and is offered inmany different voltages and currents.
• End of stroke limit outputs indicate whenthe actuator reaches the fully retracted andextended positions.
• These outputs can be set at the factory as,active low or active high independently and aregood for up to 1 Amp.
• Live power feature is available to maintain allof these output signals when switched poweris off.
• IP50 Standard or IP65 Dynamic, IP69KStatic Configurable.
• Temporary Immersion Boot availableupon request. Consult factory.
Features to Adjustable Control• 4 adjustable stop positions using a simple 4
button membrane keypad.
• Customer can adjust Retract & Extendstops using membrane keypad. These valueswill be stored in permanent EEPROM memoryfor the life of the actuator.
• Adjusted stop positions can also be erasedat any time to go back to factory default.
• Retract is Stop 1 and Extend is Stop 2. Stop 3and Stop 4 can be set anywhere inside thesetwo values.
• When Stop 1 (Retract) and Stop 2 (Extend)positions are reached the actuator willautomatically stop and not allow movement inthat direction. Power will have to be reversed inthe opposite direction to move the actuator.
• If Stop 3 and Stop 4 positions are used, whenthese positions are reached the control willremove power to the actuator until input poweris cycled. Then when power is reapplied it canmove in either direction.
• Positional Accuracy, under no load conditionsfrom the initial stop position setting is within0.10". This will improve with loaded applicationssince there will be less coast.
• Repeatability of hitting the same stop positionevery time is within .010".
Typical Applications• Indoor Office Equipment
• Medical
• Deck Lifts
• Gate Openers
ARTEN Freios e Embreagens - Fone: 11 5594-8333
14 .....P-1581-WL 2/16
4567
7 6 5 4 3 2
WARNER LINEAR
SCALE 2:3
SIZE PART NUMBERC
ALL DIMENSIONS ARE NOMIMAL MAXMATERIAL CONDITION UNLESS TOLERANCESARE APPLIED TO DIRECTLY TO EACH DIMENSIONCONTACT WARNER LINEAR FOR ADDITIONALINFORMATION ON MANUFACTURINGTOLERANCES
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
S Track Dimensions
SEE BOM
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Wednesday, July 27, 2011 8:30:10 AM
[ 69 ]2.72
[ 106.4 ]4.19
[ 51.6 ]2.03
[ 43.9 ]1.73
[ 32.2 ]1.27
[ 35.4 ]1.39
[ 19.8 ].78
[ 37 ]1.46
[ 7.9 ].31
[ 14.5 ].57
[ 11 ].43
[ 9 ].36
[19.92±0.13]Ø .784±.005
[ 181.1 ]7.13
9.659.53
Ø .380.375
[ ]
S-TrackDimensions & Configurator
S-Track Configurator
G11 12VP1S1 DN– – – –08 1
Actuator Model No.
S1 – Aluminum HousingS2 – Plastic Housing
Voltage
12 – 12 VDC24 – 24 VDC
Dimensions
Stroke “A”2" (50 mm) 9.324" (100 mm) 9.326" (150 mm) 11.328" (200 mm) 13.3210" (254 mm) 15.3212" (300 mm) 17.32
End Fitting
Blank– STDR90 – 90
Stroke Length
02 – 02 in. (50 mm) 04 – 04 in. (100 mm)06 – 06 in. (150 mm)08 – 08 in. (200 mm)10 – 10 in. (250 mm)12 – 12 in. (300 mm)
Gear Ratio
G07 1" 44 .375 - 8 screwG11 .75" 44 .375 - 12 screwG14 .62" 44 .375 - 16 screwG17 .50" 18 .375 - 8 screwG26 .33" 18 .375 - 12 screwG35 .25" 18 .375 - 16 screw
IP-Rating
Blank– IP 501 – IP 65/IP69K
Output/Limit Switch
P0 – Basic Control, No Outputs
P1 – S-Track Basic Control, POT output and Limit Switches
K1 – Key Pad Control
Dimensions
S-Track Stroke
in. mm in. mm in. mm in. mm in. mm
4 102 6 152 8 203 10 254 12 305
A 9.32 236.7 11.32 287.5 13.32 338.3 15.32 389.1 17.32 439.9
Note: Special lengths available
MALE METRIPACK 150 (SHOWN)MATES TO ACTUATOR HOUSINGUSE 16AWG WIRESPIN A: LIVE POWER (+)PIN B: EXTEND LIMIT OUTPUTPIN C: LIVE INPUTPIN D: LIVE POWER (-)PIN E: RETRACT LIMIT OUTPUTPIN F: POTENTIOMETER OUTPUTPIN G: LIVE GROUNDPIN H: SIGNAL GROUND
VENT FOR .125" [3.18]BREATHER TUBE
["A"]"A" RETRACTED
STROKE TOLERANCEIS +/-.078 [1.98]
THRUBOTH ENDS
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
For Protective BootConsult factory for ordering details.
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
ARTEN Freios e Embreagens - Fone: 11 5594-8333
15P-1581-WL 2/16....6
S-TrackWiring Diagram & Performance Graphs
Imperial* Measurements
S Track G07-12VDC
S Track G11-12VDC
S Track G07-24VDC
S Track G11-24VDC
0.95
0.97
0.99
1.01
1.03
1.05
1.07
1.09
1
1.5
2
2.5
3
3.5
4
4.5
0 25 50 75 100 125
S Track G07-12VDC Nominal Performance
Current Draw Speed
0.95
0.97
0.99
1.01
1.03
1.05
1.07
1.09
0.5
0.75
1
1.25
1.5
1.75
2
2.25
0 25 50 75 100 125
S Track G07-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.62
0.65
0.68
0.71
0.74
0.77
0.8
0.83
0
1
2
3
4
5
6
0 25 50 75 100 125 150 175
S Track G11-12VDC Nominal Performance
Current Draw Speed
0.62
0.65
0.68
0.71
0.74
0.77
0.8
0.83
0
0.5
1
1.5
2
2.5
3
0 25 50 75 100 125 150 175
S Track G11-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
Load Capacity 125 lbs.
Load Capacity 175 lbs.
Wiring Diagram for Basic and Adjustable Control
Metri-PackConnector12047937
Plugs intoconnector cavity on S-TrackActuator
Pin A: 12/24VDC Input Power
Pin D: 12/24VDC Input Power
Pin B: Extend Limit Output, 12/24VDC @ 1 Amp
Pin C: +12/24VDC Live Power Input
Pin E: Retract Limit Output, 12/24VDC @ 1 Amp
Pin F: Analog Output, 0-10 VDC
Pin G: Live Power Ground Input
Pin H: Signal Ground
Extend = Pin A + & Pin D –Retract = Pin A – & Pin D +
Customer SuppliedSwitch EXAMPLE:Momentary DPDT
Switch with Center Off 12VDC, 15 Amp
24VDC, 7.5 AmpFuse Recommended
InputPower
12/24VDC
1 Amp FuseRecommended
Extend Lamp, Relay, or Isolated PLC Input
Extend Lamp, Relay, or Isolated PLC Input
Display, Meter, or Isolated PLC Input
S-Track Actuator
All dashed lines are customer supplied
connections
Performance Graphs Imperial SpeedCurrent Draw
Measurements**Performance Chart Measurements are Nominal
For Metric Measurements, see pages 17-18.
For Metric Measurements, see pages 17-18.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
16 .....P-1581-WL 2/16
S-Track
0.4
0.43
0.46
0.49
0.52
0.55
0
1
2
3
4
5
0 25 50 75 100 125 150 175 200 225 250
S Track G17-12VDC Nominal Performance
Current Draw Speed
0.4
0.43
0.46
0.49
0.52
0.55
0
0.5
1
1.5
2
2.5
0 25 50 75 100 125 150 175 200 225 250
S Track G17-24VDC Nominal Performance
Current Draw Speed
0.28
0.29
0.3
0.31
0.32
0.33
0.34
1
2
3
4
5
6
0 50 100 150 200 250 300
S Track G26-12VDC Nominal Performance
Current Draw Speed
0.28
0.29
0.3
0.31
0.32
0.33
0.34
0.5
1
1.5
2
2.5
3
0 50 100 150 200 250 300
S Track G26-24VDC Nominal Performance
Current Draw Speed
S Track G17-12VDC
S Track G26-12VDC
S Track G14-12VDC
S Track G35-12VDC
S Track G17-24VDC
S Track G26-24VDC
S Track G14-24VDC
S Track G35-24VDC
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Load - lbs
Load - lbs
Load - lbs
Load - lbs
0.45
0.48
0.51
0.54
0.57
0.6
0.63
0
1
2
3
4
5
6
0 25 50 75 100 125 150 175 200 225
S Track G14-12VDC Nominal Performance
Current Draw Speed
0.45
0.48
0.51
0.54
0.57
0.6
0.63
0
0.5
1
1.5
2
2.5
3
0 25 50 75 100 125 150 175 200 225
S Track G14-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.17
0.19
0.21
0.23
0.25
0.27
0
1
2
3
4
5
6
7
0 50 100 150 200 250 300 350 400
S Track G35-12VDC Nominal Performance
Current Draw Speed
0.17
0.19
0.21
0.23
0.25
0.27
0
0.5
1
1.5
2
2.5
3
3.5
0 50 100 150 200 250 300 350 400
S Track G35-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
Load Capacity 300 lbs.
Load Capacity 250 lbs.
Load Capacity 225 lbs.
Load Capacity 400 lbs.
Performance Graphs Imperial SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see pages 17-18.
For Metric Measurements, see pages 17-18.
For Metric Measurements, see pages 17-18.
For Metric Measurements, see pages 17-18.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
17P-1581-WL 2/16....6
S-Track
S Track G07-12VDC
S Track G11-12VDC
S Track G07-24VDC
S Track G11-24VDC
24
24.5
25
25.5
26
26.5
27
27.5
1
1.5
2
2.5
3
3.5
4
4.5
0 111 223 334 445 556
S Track G07-12VDC Nominal Performance
Current Draw Speed
24
24.5
25
25.5
26
26.5
27
27.5
0.5
0.75
1
1.25
1.5
1.75
2
2.25
0 111 223 334 445 556
S Track G07-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
16
17
18
19
20
21
0
1
2
3
4
5
6
0 111 223 334 445 556 668 779
S Track G11-12VDC Nominal Performance
Current Draw Speed
16
17
18
19
20
21
0
0.5
1
1.5
2
2.5
3
0 111 223 334 445 556 668 779
S Track G11-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
11
12
13
14
15
16
0
1
2
3
4
5
6
0 111 223 334 445 556 668 779 890 1001
S Track G14-12VDC Nominal Performance
Current Draw Speed
11
12
13
14
15
16
0
0.5
1
1.5
2
2.5
3
0 111 223 334 445 556 668 779 890 1001
S Track G14-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
Load Capacity 556 N
Load Capacity 779 N
Load Capacity 1001 N S Track G14-12VDC S Track G14-24VDC
SpeedCurrent Draw
Performance Graphs MetricMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see pages 15-16.
For Imperial Measurements, see pages 15-16.
For Imperial Measurements, see pages 15-16.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
18 .....P-1581-WL 2/16
Load Capacity 1113 N
Load Capacity 1335 N
Load Capacity 1780 N
S-Track
S Track G17-12VDC
S Track G26-12VDC
S Track G17-24VDC
S Track G26-24VDC
S Track G35-12VDC S Track G35-24VDC
10
10.5
11
11.5
12
12.5
13
13.5
0
1
2
3
4
5
0 111 223 334 445 556 668 779 890 1001 1113
S Track G17-12VDC Nominal Performance
Current Draw Speed
10
10.5
11
11.5
12
12.5
13
13.5
0
0.5
1
1.5
2
2.5
0 111 223 334 445 556 668 779 890 1001 1113
S Track G17-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
7
7.25
7.5
7.75
8
8.25
8.5
1
2
3
4
5
6
0 223 445 668 890 1113 1335
S Track G26-12VDC Nominal Performance
Current Draw Speed
7
7.25
7.5
7.75
8
8.25
8.5
0.5
1
1.5
2
2.5
3
0 223 445 668 890 1113 1335
S Track G26-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
4
4.5
5
5.5
6
6.5
7
0
1
2
3
4
5
6
7
0 223 445 668 890 1113 1335 1558 1780
S Track G35-12VDC Nominal Performance
Current Draw Speed
4
4.5
5
5.5
6
6.5
7
0
0.5
1
1.5
2
2.5
3
3.5
0 223 445 668 890 1113 1335 1558 1780
S Track G35-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
Performance Graphs Metric Speed Current DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see pages 15-16.
For Imperial Measurements, see pages 15-16.
For Imperial Measurements, see pages 15-16.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
19P-1581-WL 2/16....6
I-TrackGeneral Duty In-line Actuator DC Motor Ball Screw
I-Track is a general duty inline actuator suited for applications needing a power-off releasing the rod into a float mode. This unit utilizes a ball screw and planetary drive for long life in a compact space. Models can be fitted with a potentiometer that is directly coupled to the rod that will provide position feedback regardless if the rod is in float or locked mode. It can be driven by PWM to control velocity. For controlling the float and locked rod setting there is a separate input independent of the motor connection. The rod can also be configured to be permanently locked for applications where a floating rod is not required. The unit incorporates a ratchet-free overload slip clutch to protect the drive system.
Up to 200 lbs. (890 N) Rated LoadUp to 1 in. (25 mm)/sec. Travel Speed
Features• Models available in 12VDC and 24VDC.
• Loads up to 200 lbs thrust.
• In-line design reduces base footprint.
• Releasing clutch allows rod to float with clutch power-off. Clutch power is separate from motor power.
• Clutch also acts as over-load protection.
• Motor thermal for added motor protection.
• Optional Potentiometer output scaled to stroke.
• Can be driven by PWM (not supplied) controller to achieve multiple velocities.
• Can be mounted at the body by trunnions (shoulder bolts) or as traditional clevis.
• Rod end mounts are configurable.
• Ball screw and nut for long life.
• Operating temperatures -40° F to +185° F (-40° C to 85° C).
• Steel rod for durability.
• Nitrile impregnated gaskets for superior sealing.
• Black powder coat for 250 hour salt spray protection.
• Nitrotec® coated steel components for 250 hour Salt Spray Protection.
• IP69K Static; IP66 Dynamic. Rod bellow will allow for temporary operation IP67 submersion.
Typical Applications• Throttle controls
• Mobility lifts for vehicles requiring manual operation in emergency situations
• Hydraulic flow controls
• Bus Door Operator
• Hatch lift applications
• Handicap Van Lifts
• Engine Controls
• Emergency Door (lock and unlock via VDC)
SpecificationsOperating Voltage 9-15VDC or 22-26VDC
Passed EMI Immunity Testing
ISO 11452-4 Certified
Operating Load 200 lbs. (890 N) Thrust, 800 lbs. (3,559 N) Static
Stroke Length 2, 4, 6, 8, 10 and 12
Duty Cycle 25% max.
No-Load Speed 1.1"/SEC (27.94 mm/sec)
Floating Rod Design
Operation Temperatures Range
-40° F to 185° F (-40° C to 85° C)
Potentiometer 560-10K Optional
Environment IP69K Static, IP66 Dynamic
ARTEN Freios e Embreagens - Fone: 11 5594-8333
20 .....P-1581-WL 2/16
I-TrackPerformance Graphs Imperial & Metric Speed
Current DrawMeasurements**Performance Chart Measurements are Nominal
G05-12VDC G05-24VDC
Imperial Measurements* I Track Operating Load 200 Lbs.
I Track G05-24VDC
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1
2
3
4
5
6
7
8
9
0 25 50 75 100 125 150 175 200
Spee
d -
IPS
Curr
ent D
raw
- A
mps
Load - lbs
I Track G05-12VDC Nominal Performance
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 25 50 75 100 125 150 175 200
Spee
d -
IPS
Curr
ent D
raw
- A
mps
Load - lbs
I1XG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
Metric Measurements* I Track Operating Load 890 NG05-12VDC G05-24VDC
14
16
18
20
22
24
26
28
1
2
3
4
5
6
7
8
9
0 111 223 334 445 556 668 779 890
Spee
d -
MM
PS
Curr
ent D
raw
- A
mps
Load - N
I Track G05-12VDC Nominal Performance
14
16
18
20
22
24
26
28
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0 111 223 334 445 556 668 779 890
Spee
d -
MM
PS
Curr
ent D
raw
- A
mps
Load - N
I1XG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
I-Track Configurator
I1X P G05 – 12V – 02
Potentiometer
P – PotentiometerBlank– No Potentiometer
Stroke Length
02 – 2 in (50 mm)03 – 3 in (75mm)04 – 4 in (100 mm)06 – 6 in (150 mm)08 – 8 in (200 mm)10 – 10 in (250 mm)12 – 12 in (300 mm)Gear Ratio
G05 – 5:1 200LBF
Actuator Model No.
I1X – I-track
Voltage
12V – 12 volt DC24V – 24 volt DC
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
ARTEN Freios e Embreagens - Fone: 11 5594-8333
21P-1581-WL 2/16....6
I-TrackDimensions
AA [36.49+0.50]-0.20
1.44 +0.02 -0.01
BB[19.35
+0.40]-0.20
.76 +0.02 -0.01
CC[68.66
+0.40 ]-0.20
2.70 +0.02 -0.01
DD[34.55±0.51]
1.36±.02
EE[92.02
+0.50 ]- 0.20
3.62 +0.02 - 0.01
FF[75.79
+0.40 ]- 0.20
2.98 +0.02 - 0.01
GG[19.91±0.25]
Ø .78±.01
HH[29.54
+0.60 ]- 0.10
1.16 +0.02 - 0.00
I I[30.31±0.51]
1.16±.02
JJ[60.63
+0.40 ]- 0.20
2.39 +0.02 - 0.01
Dimensions (Side Views)
Dimensions
I-Track
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm in. mm
2 50 3 75 4 100 6 150 8 200 10 254 12 300
A 2.00 50.80 3.00 76.20 4.00 101.60 6.00 152.40 8.00 203.20 10.00 254.00 12.00 304.80
B 1.69 42.93 2.69 68.33 3.69 93.73 5.69 144.53 7.69 195.33 9.69 246.13 11.69 296.93
C 7.65 194.31 8.65 219.71 9.65 245.11 11.65 295.91 13.65 346.71 15.65 397.51 17.65 448.31
D 13.29 337.57 14.29 362.97 15.29 388.37 17.29 439.17 19.29 489.97 21.29 540.77 23.29 591.57
E 14.42 366.27 15.42 391.67 16.42 417.07 18.42 467.87 20.42 518.67 22.42 569.47 24.42 620.27
Note: Special lengths available
22.86 +-0.760.51
.90 +-.03.02
B±0.50B±.02
D±0.50D±.02
E±0.50E±.02
C±0.50C±.02
36.97 +-0.600.20
1.46 +-.02.01
9.55 + 0.130
Ø .376 +-.005.000
2x Ø .27 .78 M8X1.25 - 6H .63
15.75.62
31.811.25
"A"±0.51"A"±.02
M10 X 1.5-6g
I1XG05-12V-XXOPERATING VOLTAGE: 9-15VDC FOR 12VDC NOMINAL 22-26VDC FOR 24VDC NOMINALOPERATING TEMPERATURE: -40 TO160 F (-40 C TO 71 C)ENVIRONMENT: IP66 OPERATING IP69K STATICPASSED EMI IMMUNITY TESTINGOPERATING LOAD: 200 LBS THRUST 800 LBS STATICNO-LOAD SPEED: 1.1"/SECFLOATING ROD DESIGNOPTIONAL POTENTIOMETER
WARNER LINEAR
UNLESS NOTED:DIMENSIONS ARE IN MMTOLERANCES:
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
MATERIAL
TITLE
INLINE ACTUATOR
DIMENSIONAL OUTLINE9/10/2014JRZ
9/10/2014JRZ
Monday, October 24, 2011 2:00:58 PM
AA
BB
CC
DD
EE
FF
HH
GG
I I
JJ
9.53 +-0.250.25
.38 +-.01.01
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
Integral Connector Mates To TycoConnector Part Number:776494-1 8 Position, Socket Housing, Key Position 1
Connections: Port 1= Motor (Connect-12vdc Tp Retract)Port 2= Clutch (-12vdc)Port 3= Optional Potentiometer Input VdcPort 4= Optional Potentiometer Input VdcPort 5= Optional Vent Tube (Consult Factory)Port 6= Optional Potentiometer Output VdcPort 7= Clutch (+12vdc)Port 8= Motor Connect (+12vdc To Retract)
Retracted
(Both Sides)
FLATSFor Mounting
ARTEN Freios e Embreagens - Fone: 11 5594-8333
22 .....P-1581-WL 2/16
B-Track FeaturesRugged Duty Actuators
Unique screw end bearing guide provides smooth extension operation, high side load capability and aids in screw re-lubrication. (Patented)
Threaded rod connection allows optional end fittings.
Hydraulic Cylinder type Rod Wiper Seal with
integral extension rod bearing support for
smooth operation and high side load capability.
Nitrotec®
treated end fitting for superior strength and corrosion resistance.
Ball bearing, Bronze or Delrin® screw nut configurations provide broad load and performance capability.
Nitrotec® treated steel extension rod provides 40% stronger cross section compared to competitive products.
Efficient gear design minimizes motor bearing
load. Gear materials selected for high load impact and durability.
Gear profile optimized for quiet operation. High
performance synthetic lifetime lubes used
throughout.
High strength aluminum gear box provides maximum heat dissipation. High strength stainless thru-bolt fasteners provide high load capability. O-ring sealed and gasketed for washdown use.
Bi-directional holding brake standard on K2x models.
Optional electronic control module with integral electronic stroke limits and power connections. Adjustable torque limit option. For more information see Controls Section.
Mechanical torque limiter for end of stroke and overload protection.
Heavy Duty, Sealed Double Ball Bearing Motors• Auto reset thermal protection• Easy field replacement• 12, 24, 48 or 90 volts (vdc) available
(others available on request)• Standard Packard 56 connector,
others available• Washdown sealed• Solid mount pinion gear• Lifetime bearing lube
Integrated manual override – standard
Patented in-line design transfers loads to the end fitting via ball bearing screw pivot. Efficient load transfer reduces noise and current draw.
Nitrotec® treated end fittings with integral O-ring seals for superior weather and corrosion resistance. 6 available mounting orientations.
Key Features• Weather-tight sealed• Patented in-line load transfer• Heavy wall rod and cover tube• High performance motors• Up to 2,800 lb. (12455 N) capacity• Speeds up to 2" per second
Standard ModelsK2vl, K2, K2x, K2ac, K2xac
Option ModelsK2Pl/K2xPl
K2JS/K2xJS
K2Ra
Heavywall extension tube has 30% stronger cross section compared to competitive products.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
23P-1581-WL 2/16....6
B-Track Configurator
How To SelectStep 1 – Determine Load and Stroke length requirementsUse the Quick Selection guide to identify the model family that will provide the load capacity and stroke length needed for your application.
Step 2 – Determine Gear RatioSelect gear ratio from performance charts for allowable current draw and needed load.
Step 3 – Identify motor type and voltageSelect DC motor and motor voltage.
Step 4 – Motor TypeSelect M for ignition protected motor (12 VDC only). Select needed motor voltage.
Step 5 – Confirm the application Duty CycleAt full load capacity, actuators have a 25% duty cycle. Duty cycle is the amount of ‘on-time’ compared to cooling time. A unit that runs for 15 seconds should be off for 45 seconds.
Step 6 – Select Nut TypeSelect nut for unit selected. (K2x are all ball bearing).
Step 7 – Select Stroke LengthChoose standard lengths from chart. For special length consult factory.
Step 8 – Select end fitting orientationLeave blank for standard orientation.
Important Unit Restrictions
Side loading and shock loads must be considered in actuator applications. Side loading and cantilevered mounting should be eliminated through proper machine design. Side loading will dramatically reduce unit life. While actuators can withstand limited shock loads, it is recommended that shock loading be avoided wherever possible. (See page 71)
150 °= R150
120 ° =R120
90 ° =R90
60 ° =R60
30 ° =R30
B-Track Configurator
G20 12VP1.xK2x M– –– –BR 04 R120
Nut Type*
Blank– K2xBR – Bronze NutBRL – Bronze Nut - LongDN – Delrin® Nut
*BRL matches K2x pin to pin
Stroke Length
04 – 4.00 (100 mm)06 – 6.00 (150 mm)08 – 8.00 (200 mm)12 – 12.00 (300 mm)18 – 18.00 (450 mm)24 – 24.00 (600 mm)
Gear Ratio
G30 = 30:1G20 = 20:1G10 = 10:1G05 = 5:1
Base Fitting Alignment
Blank– Standard R30 – 30˚ FittingR60 – 60˚ FittingR90 – 90˚ FittingR120 – 120˚ FittingR150 – 150˚ Fitting
Actuator Model No.
K2xK2K2vl
Motor Voltage
12V – 12 volts
24V – 24 volts
36V – 36 volts
48V – 48 volts
90V – 90 volts
115V – 115 volts
230V – 230 volts
Control Model
P1.x Fixed Limit SwitchP2.x Position FeedbackEP1.x Adjustable Limit
SwitchesRP Low Switching
(K2vl Not Available)
Note: See control pages for full listing of model numbers.
Motor Type
M – Ignition Protected MotorFor standard motor, leave blank.
STANDARD
CL CL LOCATION OF CLEVIS PIN
Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6
ARTEN Freios e Embreagens - Fone: 11 5594-8333
24 .....P-1581-WL 2/16
B-Track K2vl
General Duty Actuator DC Motor Acme Screw
This value model of the B-track family is well suited for the toughest applications not needing the full load capability of standard K2 models. The K2vL uses a flange bronze bearing configuration for internal load transfer, offering the lowest cost while maintaining the rugged-duty performance capabilities of the B-track family.
K2vL units feature Nitrotec® corrosion protection on end fittings and rods, high performance powder coat paint on cover tubes and gear box covers, providing a totally sealed, weatherproof, and durable finish for years of trouble-free service.
Up to 600 lbs. (2669 N) Rated LoadUp to 2.7 in. (68.58 mm)/sec. Travel Speed
• Maximum Static Rating: 3,000 lbs. (13345 N) Static(in-line load)
• Refer to performance chart for load/current/speedcapabilities
• Stroke Length Tolerance: +/-.06” (1.52mm)
• Motor is protected with auto reset breaker inside motorhousing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent,suggested guidelines are:- 50% max on-time/50% off-time for loads up to 50%
of capability- 25% max on-time/75% off-time for loads between
50%-80% of capability- 10% max on-time/90% off-time for loads between
80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C)
• Weather resistant enclosure & seals (IP69K Static, IP65capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 10-16 vdc (Ratings are at 12vdc Normal.)
• 14 gauge stranded lead wires-UL style 1230 w/PVCinsulation Class F 105° C
• Use momentary contact double pole/double throw switchin powering unit for extend/retract operation.(ON)-OFF-(ON) DPDT
• Connectors:- Packard 56 series or Delphi Weather-Pack
- Packard 56 series with 56 series blades(#2984883 & #2962987)
- Delphi Weather-Pack series (#121015792 & #12010973)
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
Features• Protective coatings and O-ring seals
throughout
• Hybrid nut and screw design, nobrake needed
• Ball detent over load clutch
• Stroke lengths 2 to 12 inches(50 to 300 millimeters)
• Load capacities up to 600 pounds (2669 N)
• Speeds up to 2.7 inches(68.58 millimeters)/sec. travel
• Thermal overload incorporated intothe motor
• Heavy wall construction
• Double ball bearing motors
• Heat treated gears
• Rugged extension rod bearing support
Typical Applications• Flow gate open/close
• Deck and implement lifts for tractors andmobile applications
• Wheelchair and scooter lifts
• Bin and tank cover lifts
• Remote engine clutch engagement
ARTEN Freios e Embreagens - Fone: 11 5594-8333
25P-1581-WL 2/16....6
B-Track K2vl
K2vlG05-12VDC
k2vlG10-12VDC
k2vlG20-12VDC
k2vlG05-24VDC
k2vlG10-24VDC
k2vlG20-24VDC
1.75
2
2.25
2.5
2.75
3
3.25
0
5
10
15
20
25
0 25 50 75 100 125 150 175 200
K2VLG05-12VDC Nominal Performance
Current Draw Speed
1.75
2
2.25
2.5
2.75
3
3.25
0
2.5
5
7.5
10
12.5
0 25 50 75 100 125 150 175 200
K2VLG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.8
0.9
1
1.1
1.2
1.3
1.4
0
5
10
15
20
25
0 50 100 150 200 250 300
K2VLG10-12VDC Nominal Performance
Current Draw Speed
0.8
0.9
1
1.1
1.2
1.3
1.4
0
2.5
5
7.5
10
12.5
0 50 100 150 200 250 300
K2VLG10-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0
5
10
15
20
25
0 100 200 300 400 500 600
K2VLG20-12VDC Nominal Performance
Current Draw Speed
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2VLG20-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Load - lbs Load - lbs
Load Capacity 200 lbs.
Load Capacity 300 lbs.
Load Capacity 600 lbs.
SpeedCurrent Draw
Performance Graphs ImperialMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 26.
For Metric Measurements, see page 26.
For Metric Measurements, see page 26.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
26 .....P-1581-WL 2/16
B-Track K2vl
k2vlG05-12vDc
k2vlG10-12vDc
k2vlG20-12vDc
k2vlG05-24vDc
k2vlG10-24vDc
k2vlG20-24vDc
1.75
2
2.25
2.5
2.75
3
3.25
0
5
10
15
20
25
0 25 50 75 100 125 150 175 200
K2VLG05-12VDC Nominal Performance
Current Draw Speed
1.75
2
2.25
2.5
2.75
3
3.25
0
2.5
5
7.5
10
12.5
0 25 50 75 100 125 150 175 200
K2VLG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
0.8
0.9
1
1.1
1.2
1.3
1.4
0
5
10
15
20
25
0 50 100 150 200 250 300
K2VLG10-12VDC Nominal Performance
Current Draw Speed
0.8
0.9
1
1.1
1.2
1.3
1.4
0
2.5
5
7.5
10
12.5
0 50 100 150 200 250 300
K2VLG10-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0
5
10
15
20
25
0 100 200 300 400 500 600
K2VLG20-12VDC Nominal Performance
Current Draw Speed
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2VLG20-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
Load Capacity 890 N
Load Capacity 1335 N
Load Capacity 2670 N
Performance Graphs Metric SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 25.
For Imperial Measurements, see page 25.
For Imperial Measurements, see page 25.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
27P-1581-WL 2/16....6
[ ]D
C
B
AA
B
C
D
145678
8 7 6 5 4 3 2 1
E
F
E
F
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
REV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2VL Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
NW
Friday, October 21, 2005 7:41:48 AM
[39.51±0.13]1.54±.005
[109.76±0.30]4.321±.012
[148.88±0.43]5.861±.017
[78.63±0.38]3.08±.015
Ø 2.50 - .05+.01
63.5 -1.3+0.3
6.924±.200[175.86±5.08]
[24.24±0.46].954±.018
[14.87±0.56].585±.022
[13.46±0.38].530±.015
[16.63±1.52].655±.06028.58 0
-0.08
Ø 1.125 +-
.000
.003
[11.43±0.38].450±.015
50.80 +0.300
Ø 2.000 +-
.012
.000
[25.40±0.38]Ø 1.000±.015
12.9312.78
Ø .509.503
[ ]
[ ]
[ ]
B-Track K2vl
Dimensions
Dimensions
B-Track K2vl
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
2 51 4 102 6 152 8 203 10 254 12 305
A 8.32 211.3 10.32 262.1 12.32 312.9 14.32 363.7 16.32 414.5 18.32 465.3
Note: Special lengths available
BARE WIRES
["A" ±3.18]"A"±.125 RETRACTED STROKE TOLERANCE
IS +/- .060 [1.52]
10"/[254] LEAD WIRE LENGTH CONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATOR PACKARD 56 CONNECTOR
THRUBOTH ENDS
(ROD)
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
28 .....P-1581-WL 2/16
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for load/current/speed capabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (IP69K Static, IP65 capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 10-16 vdc (Ratings are at 12 vdc Normal.)
• 14 gauge stranded lead wires-UL style 1230 w/PVC insulation Class F 105°C
• Lead wires abrasion protected with spiral covering
• Use momentary contact double pole/double throw switch in powering unit for extend/retract operation. (ON)-OFF-(ON) DPDT
• Connectors: - Packard 56 series or Delphi Weather-Pack - Packard 56 series with 56 series blades (#2984883 & #2962987) - Delphi Weather-Pack series (#121015792 & #12010973) Upon Request
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
B-Track K2Rugged Duty Actuator DC Motor Acme Screw
Features • Protective coatings and O-ring seals
throughout• Patented in-line load system• Hybrid Acme style nut and screw design,
no brake needed• Ball detent over load clutch • Stroke lengths 2 to 24 inches
(50 to 600mm) • Load capacities up to 1500 pounds
(6672 N) • Speeds up to 2.7 inches
(68.58 millimeters)/sec. travel• Thermal overload incorporated
into the motor• Heavy wall construction• Double ball bearing motors • Heat treated gears• Rugged extension rod bearing support• Optional 90 vdc motor for use with
SBC-AC control (IP54)• Custom mounting options available
Typical Applications • Heavy duty platform and engine lifts• Deck and implement lifts for tractors and
mobile applications• Table positioning• Wheelchair and scooter lifts• Bin and tank cover lifts
• Flow gate open/close
Up to 1,500 lbs. (6672 N) Rated LoadUp to 2.7 in. (68.58 mm)/sec. Travel Speed
The K2 is the base model in the B-Track family. It incorporates a patented in-line load transfer design which provides high load capability for rugged-duty use, efficient power use, compact package size, excellent corrosion and washdown protection, and high performance synthetic lubrication for life, all at an affordable price.
The K2 uses a solid bronze or Delrin® nut with a rolled hybrid Acme style screw yielding high impact capability and long screw life. Heavy-duty double-ended ball bearing motors, hardened gears, O-ring seals and an extension rod bearing system that provides best in class capabilities.
Now Available Optional Adjustable Limit Switch These easy to use adjustable switches are mounted in a channel on the cover tube with custom cap for protection. They are easily moved to enable the end-user the flexibility of setting the stroke length at any position within the full stroke capability. Just pop the cap off, loosen the set screw and slide the switch into the desired position.
Shown with optional adjustable limit switch feature
Scan to watch!
How to Adjust the Limit Switches for a K2 or K2X Actuator with External or EP Limit Switches https://p.widencdn.net/imzc9v
ARTEN Freios e Embreagens - Fone: 11 5594-8333
29P-1581-WL 2/16....6
B-Track K2
1.5
1.75
2
2.25
2.5
2.75
3
0
5
10
15
20
25
0 50 100 150 200 250 300
K2G05-12VDC Nominal Performance
Current Draw Speed
1.5
1.75
2
2.25
2.5
2.75
3
0
2.5
5
7.5
10
12.5
0 50 100 150 200 250 300
K2G05-24VDC Nominal Performance
Current Draw Speed
0.5
0.7
0.9
1.1
1.3
1.5
0
5
10
15
20
25
0 100 200 300 400 500 600
K2G10-12VDC Nominal Performance
Current Draw Speed
0.5
0.7
0.9
1.1
1.3
1.5
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2G10-24VDC Nominal Performance
Current Draw Speed
0.34
0.4
0.46
0.52
0.58
0.64
0.7
0.76
0
5
10
15
20
25
0 200 400 600 800 1000 1200
K2G20-12VDC Nominal Performance
Current Draw Speed
0.34
0.4
0.46
0.52
0.58
0.64
0.7
0.76
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200
K2G20-24VDC Nominal Performance
Current Draw Speed
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0
5
10
15
20
25
0 300 600 900 1200 1500
K2G30-12VDC Nominal Performance
Current Draw Speed
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0
2.5
5
7.5
10
12.5
0 300 600 900 1200 1500
K2G30-24VDC Nominal Performance
Current Draw Speed
K2G05-12VDC
K2G10-12VDC
K2G20-12VDC
K2G30-12VDC
K2G05-24VDC
K2G10-24VDC
K2G20-24VDC
K2G30-24VDC
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load Capacity 300 lbs.
Load Capacity 600 lbs.
Load Capacity 1200 lbs.
Load Capacity 1500 lbs.
SpeedCurrent Draw
Performance Graphs ImperialMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 30.
For Metric Measurements, see page 30.
For Metric Measurements, see page 30.
For Metric Measurements, see page 30.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
30 .....P-1581-WL 2/16
B-Track K2
1.5
1.75
2
2.25
2.5
2.75
3
0
5
10
15
20
25
0 50 100 150 200 250 300
K2G05-12VDC Nominal Performance
Current Draw Speed
1.5
1.75
2
2.25
2.5
2.75
3
0
2.5
5
7.5
10
12.5
0 50 100 150 200 250 300
K2G05-24VDC Nominal Performance
Current Draw Speed
0.5
0.7
0.9
1.1
1.3
1.5
0
5
10
15
20
25
0 100 200 300 400 500 600
K2G10-12VDC Nominal Performance
Current Draw Speed
0.5
0.7
0.9
1.1
1.3
1.5
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2G10-24VDC Nominal Performance
Current Draw Speed
0.34
0.4
0.46
0.52
0.58
0.64
0.7
0.76
0
5
10
15
20
25
0 200 400 600 800 1000 1200
K2G20-12VDC Nominal Performance
Current Draw Speed
0.34
0.4
0.46
0.52
0.58
0.64
0.7
0.76
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200
K2G20-24VDC Nominal Performance
Current Draw Speed
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0
5
10
15
20
25
0 300 600 900 1200 1500
K2G30-12VDC Nominal Performance
Current Draw Speed
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0
2.5
5
7.5
10
12.5
0 300 600 900 1200 1500
K2G30-24VDC Nominal Performance
Current Draw Speed
K2G05-12VDC
K2G10-12VDC
K2G20-12VDC
K2G30-12VDC
K2G05-24VDC
K2G10-24VDC
K2G20-24VDC
K2G30-24VDC
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PSSp
eed
- IP
S
Spee
d -
IPS
Spee
d -
MM
PSSp
eed
- M
MPS
Sp
eed
- IP
S
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load Capacity 2670 N
Load Capacity 5340 N
Load Capacity 6675 N
Load Capacity 1335 N
Performance Graphs Metric Speed Current DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 29.
For Imperial Measurements, see page 29.
For Imperial Measurements, see page 29.
For Imperial Measurements, see page 29.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
31P-1581-WL 2/16....6
4567
7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2 Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Friday, October 21, 2005 7:41:48 AM
[39.12±0.13]1.540±.005
[109.76±0.30]4.321±.012
[148.88±0.43]5.861±.017
[78.23±0.38]3.080±.015
Ø 2.50 - .05+.01
63.5 -1.3+0.3
6.969±.200[177±5.08]
[24.24±0.46].954±.018
[14.87±0.56].585±.022
[13.46±0.38].530±.015
[11.43±0.38].450±.015
50.80 +0.300
Ø 2.000 +-
.012
.00028.58 -
00.08
Ø 1.125 +-
.000
.003
[18.31±1.52].721±.060
[25.40±0.38]Ø 1.000±.01512.93
12.78
Ø .509.503
[ ]
[ ]
[ ]
[ ]
B-Track K2Dimensions
B-Track K2 Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
2 51 4 102 6 152 8 203 10 254 12 305
A 8.32 211.3 10.32 262.1 12.32 312.9 14.32 363.7 16.32 414.5 18.32 465.3
Note: Special lengths available
B-Track K2 Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
14 356 16 406 18 457 20 508 22 559 24 610
A 20.32 516.1 22.32 566.9 24.32 617.7 29.32 744.7 31.32 795.5 33.32 846.3
Note: Special lengths available
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
THRU
BOTH ENDS WIRES PROTECTED WITHBLACK SPIRAL WRAP
["A"] ±3.18"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]LONGER THAN ADVERTISED
TOLERANCE IS +.036/-.005 [+.91/-.13]
(ROD)
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
32 .....P-1581-WL 2/16
B-Track K2ac
Features• Protective coatings and O-ring seals
throughout• Patented in-line load system• Hybrid nut and screw design, no brake
needed• Ball detent over load clutch• Stroke lengths 4 to 24 inches
(100 to 600 millimeters)• Load capacities up to 1100 pounds
(4893 N)• Speeds up to 1 inches
(25.4 millimeters)/sec. travel• Thermal overload incorporated
into the motor• Heavy wall construction• Double ball bearing motors• Heat treated gears• Rugged extension rod bearing support• Custom mounting options available• Limit switches offered only in the
adjustable version (EP1.x)
Typical Applications• Ergonomic lift tables• Roof vents• Conveyor diverters• Bin/tank cover lifts
Up to 1,100 lbs. (4893 N) Rated LoadUp to 1 in. (25.4mm)/sec. Travel Speed
The K2 is the base model in the B-Track family. It incorporates a patented in-line load transfer design which provides high load capability for rugged-duty use, efficient power use, compact package size, excellent corrosion and washdown protection, and high performance synthetic lubrication for life, all at an affordable price.
The K2 uses a solid bronze or Delrin® nut with a rolled hybrid screw yielding high impact capability and long screw life. Heavy-duty double-ended ball bearing motors, hardened gears, O-ring seals and an extension rod bearing system that provides best in class capabilities.
Now Available Optional Adjustable Limit Switch These easy to use adjustable switches are mounted in a channel on the cover tube with custom cap for protection. They are easily moved to enable the end-user the flexibility of setting the stroke length at any position within the full stroke capability.
• Maximum Static Rating: 3,000 lbs. (13345 N) Static(in-line load)
• Refer to performance chart for load/current/speedcapabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motorhousing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent,suggested guidelines are:- 50% max on-time/50% off-time for loads up to 50% of
capability- 25% max on-time/75% off-time for loads between
50%-80% of capability- 10% max on-time/90% off-time for loads between
80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C),-40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (IP 54 capable, 250hour salt spray, 500 hour for paint)
• Normal operating voltage: 115 VAC or 230 VAC
• 14 gauge stranded lead wires-UL style 1230 w/PVCinsulation Class F 105° C
• Use momentary contact switch in powering unit forextend/retract operation.(ON)-OFF-(ON) SPDT
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
Rugged Duty Actuator AC Motor Acme Screw
*UL Certification, consult factory
*
Scan to watch!
How to Adjust the Limit Switches for a K2 or K2X Actuator with External or EP Limit Switches https://p.widencdn.net/imzc9v
ARTEN Freios e Embreagens - Fone: 11 5594-8333
33P-1581-WL 2/16....6
B-Track K2ac
Dimensions
B-Track K2ac
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
4 100 6 150 8 200 12 300 18 450 24 600
A 14.96 380.0 16.97 431.0 18.94 481.1 22.95 582.9 28.94 735.1 34.92 887.0
Note: Special lengths available
145678
8 7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:2
SIZE PART NUMBERC
REV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2AC Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
NW
Friday, October 21, 2005 7:41:48 AM
6.157±.017[156.39±0.43]
3.080±.015[78.23±0.38]
1.540±.005[39.12±0.13]
[117.28±0.30]4.617±.012
12.625±.200[320.68±5.08]
Ø 1.125-.003+.000
28.58 -0.080
.438±.015[11.11±0.38]
1.228±.060[31.18±1.52]
.530±.015[13.46±0.38]
.585±.022[14.87±0.56]
.954±.018[24.2±0.46]
[25.40±0.38]Ø 1.000±.015
50.80 +0.300
Ø 2.000 +-.012.000
86.9 +-0.31.3
Ø 3.42 +-.01.05
12.9312.78
Ø .509.503
[ ][ ]
[ ]
[ ] THRU
BOTH ENDS
23.5" [597] CABLE W/18AWG WIRESHOT TO RED WIRE TO EXTEND
HOT TO BLACK WIRE TO RETRACTWHITE WIRE IS NEUTRAL
GROUND TO GREEN WIRE
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091LONGER THAN ADVERTISEDTOLERANCE IS +.036/-.005
(ROD)
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
34 .....P-1581-WL 2/16
B-Track K2ac
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
0 100 200 300 400 500
K2G10-115VAC Nominal Performance
Current Draw Speed
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
1.2
1.25
1.3
1.35
1.4
1.45
1.5
1.55
1.6
0 100 200 300 400 500
K2G10-230V Nominal Performance
Current Draw Speed
0.5
0.52
0.54
0.56
0.58
0.6
2.3
2.35
2.4
2.45
2.5
2.55
2.6
2.65
2.7
0 150 300 450 600 750
K2G20-115VAC Nominal Performance
Current Draw Speed
0.5
0.52
0.54
0.56
0.58
0.6
1.15
1.175
1.2
1.225
1.25
1.275
1.3
1.325
1.35
0 150 300 450 600 750
K2G20-230VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
2.25
2.3
2.35
2.4
2.45
2.5
2.55
0 100 200 300 400 500 600 700 800 900 1000 1100
K2G30-115VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
1.14
1.16
1.18
1.2
1.22
1.24
1.26
1.28
0 100 200 300 400 500 600 700 800 900 1000 1100
K2G30-230VAC Nominal Performance
Current Draw Speed
K2G10-115vac
K2G20-115vac
K2G30-115vac
K2G10-230vac
K2G20-230vac
K2G30-230vac
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load Capacity 750 lbs.
Load Capacity 1100 lbs.
Load Capacity 500 lbs.
Performance Graphs Imperial SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 35.
For Metric Measurements, see page 35.
For Metric Measurements, see page 35.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
35P-1581-WL 2/16....6
B-Track K2ac
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
0 100 200 300 400 500
K2G10-115VAC Nominal Performance
Current Draw Speed
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
1.2
1.25
1.3
1.35
1.4
1.45
1.5
1.55
1.6
0 100 200 300 400 500
K2G10-230V Nominal Performance
Current Draw Speed
0.5
0.52
0.54
0.56
0.58
0.6
2.3
2.35
2.4
2.45
2.5
2.55
2.6
2.65
2.7
0 150 300 450 600 750
K2G20-115VAC Nominal Performance
Current Draw Speed
0.5
0.52
0.54
0.56
0.58
0.6
1.15
1.175
1.2
1.225
1.25
1.275
1.3
1.325
1.35
0 150 300 450 600 750
K2G20-230VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
2.25
2.3
2.35
2.4
2.45
2.5
2.55
0 100 200 300 400 500 600 700 800 900 1000 1100
K2G30-115VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
1.14
1.16
1.18
1.2
1.22
1.24
1.26
1.28
0 100 200 300 400 500 600 700 800 900 1000 1100
K2G30-230VAC Nominal Performance
Current Draw Speed
K2G10-115vac
K2G20-115vac
K2G30-115vac
K2G10-230vac
K2G20-230vac
K2G30-230vac
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PS
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PS
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load Capacity 3338 N
Load Capacity 4895 N
Load Capacity 2225 N
Speed Current Draw
Performance Graphs MetricMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 34.
For Imperial Measurements, see page 34.
For Imperial Measurements, see page 34.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
36 .....P-1581-WL 2/16
B-Track K2xRugged Duty Actuator DC Motor Ball Screw
The K2x model provides the highest load rating in its class. This model incorporates all of the base K2 features with a ball nut screw for a 2,800 lb. (12455 N) load capability within a compact package size. The K2x includes a bi-directional wrap spring brake for load holding capability. These units are well suited for the most demanding applications where an alternative to hydraulic or air cylinders is needed or where hydraulic power sources are not available.
Combining the K2x actuator with BTc control functionality results in precision actuator control at a fraction of the cost of more complicated servo actuator systems. See Controls Section for more information on BTc controls.
Now Available Optional Adjustable Limit Switch These easy to use adjustable switches are mounted in a channel on the cover tube with custom cap for protection. They are easily moved to enable the end-user the flexibility of setting the stroke length at any position within the full stroke capability.
Up to 2,800 lbs. (12455 N) Rated LoadUp to 2.1 in. (53.34mm)/sec. Travel Speed
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for load/current/speed capabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
Load/Current/Speed/Duty Cycle
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40ºF to +176ºF (-40ºC to +80ºC) Upon Request.
• Weather resistant enclosure & seals (IP69K static, IP65 capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 10-16 vdc (Ratings are at 12 vdc Normal.)
• 14 gauge stranded lead wires-UL style 1230 w/PVC insulation Class F 105° C
• Lead wires abrasion protected with spiral covering
• Use momentary contact double pole/double throw switch in powering unit for extend/retract operation. (ON)-OFF-(ON) DPDT
• Connectors: - Packard 56 series or Delphi Weather-Pack - Packard 56 series with 56 series blades (#2984883 & #2962987) - Delphi Weather-Pack series
(#121015792 & #12010973) Upon Request
Operating Environment
Control/Connections
Features• Protective coatings and O-ring seals
throughout
• Efficient in-line ball screw system
• Integral load holding brake
• Ball detent over load clutch
• Stroke lengths 2 to 24 inches (50 to 600 millimeters)
• Load capacities up to 2,800 pounds (12455 N)
• Speeds up to 2.1 inches (53.34 mm)/sec. travel
• Thermal overload incorporated into the motor
• Heavy wall construction
• Double ball bearing motors
• Heat treated gears
• Rugged extension rod bearing support
• Optional 90 vdc motor for use with SBC-AC control (IP 54)
• Custom mounting options available
Typical Applications• Paving equipment
• Deck and implement lifts for tractors and mobile applications
• Spray booms
• Scissor and dump box lifts
Scan to watch!
How to Adjust the Limit Switches for a K2 or K2X Actuator with External or EP Limit Switches https://p.widencdn.net/imzc9v
ARTEN Freios e Embreagens - Fone: 11 5594-8333
37P-1581-WL 2/16....6
B-Track K2x
1
1.25
1.5
1.75
2
2.25
2.5
2.75
0
5
10
15
20
25
0 100 200 300 400 500 600
K2XG05-12VDC Nominal Performance
Current Draw Speed
1
1.25
1.5
1.75
2
2.25
2.5
2.75
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2XG05-24VDC Nominal Performance
Current Draw Speed
0.6
0.8
1
1.2
1.4
1.6
0
5
10
15
20
25
0 200 400 600 800 1000 1200
K2XG10-12VDC Nominal Performance
Current Draw Speed
0.6
0.8
1
1.2
1.4
1.6
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200
K2XG10-24VDC Nominal Performance
Current Draw Speed
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0
5
10
15
20
25
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
K2XG20-12VDC Nominal Performance
Current Draw Speed
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
K2XG20-24VDC Nominal Performance
Current Draw Speed
0.33
0.35
0.37
0.39
0.41
0.43
0.45
0.47
0
5
10
15
20
25
0 400 800 1200 1600 2000 2400 2800
K2XG30-12VDC Nominal Performance
Current Draw Speed
0.33
0.35
0.37
0.39
0.41
0.43
0.45
0.47
0
2.5
5
7.5
10
12.5
0 400 800 1200 1600 2000 2400 2800
K2XG30-24VDC Nominal Performance
Current Draw Speed
K2XG05-12VDC
K2XG10-12VDC
K2XG20-12VDC
K2XG30-12VDC
K2XG05-24VDC
K2XG10-24VDC
K2XG20-24VDC
K2XG30-24VDC
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load Capacity 1200 lbs.
Load Capacity 2200 lbs.
Load Capacity 2800 lbs.
Load Capacity 600 lbs.
SpeedCurrent Draw
Performance Graphs ImperialMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 38.
For Metric Measurements, see page 38.
For Metric Measurements, see page 38.
For Metric Measurements, see page 38.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
38 .....P-1581-WL 2/16
B-Track K2x
1
1.25
1.5
1.75
2
2.25
2.5
2.75
0
5
10
15
20
25
0 100 200 300 400 500 600
K2XG05-12VDC Nominal Performance
Current Draw Speed
1
1.25
1.5
1.75
2
2.25
2.5
2.75
0
2.5
5
7.5
10
12.5
0 100 200 300 400 500 600
K2XG05-24VDC Nominal Performance
Current Draw Speed
0.6
0.8
1
1.2
1.4
1.6
0
5
10
15
20
25
0 200 400 600 800 1000 1200
K2XG10-12VDC Nominal Performance
Current Draw Speed
0.6
0.8
1
1.2
1.4
1.6
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200
K2XG10-24VDC Nominal Performance
Current Draw Speed
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0
5
10
15
20
25
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
K2XG20-12VDC Nominal Performance
Current Draw Speed
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0
2.5
5
7.5
10
12.5
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
K2XG20-24VDC Nominal Performance
Current Draw Speed
0.33
0.35
0.37
0.39
0.41
0.43
0.45
0.47
0
5
10
15
20
25
0 400 800 1200 1600 2000 2400 2800
K2XG30-12VDC Nominal Performance
Current Draw Speed
0.33
0.35
0.37
0.39
0.41
0.43
0.45
0.47
0
2.5
5
7.5
10
12.5
0 400 800 1200 1600 2000 2400 2800
K2XG30-24VDC Nominal Performance
Current Draw Speed
K2XG05-12VDC
K2XG10-12VDC
K2XG20-12VDC
K2XG30-12VDC
K2XG05-24VDC
K2XG10-24VDC
K2XG20-24VDC
K2XG30-24VDC
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PSSp
eed
- M
MPS
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load - N
Load Capacity 5340 N
Load Capacity 9790 N
Load Capacity 12,460 N
Load Capacity 2670 N
Performance Graphs Metric SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 37.
For Imperial Measurements, see page 37.
For Imperial Measurements, see page 37.
For Imperial Measurements, see page 37.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
39P-1581-WL 2/16....6
B-Track K2x
Dimensions
B-Track K2x
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
2 51 4 102 6 152 8 203 10 254 12 305
A 9.89 251.2 11.89 302.0 13.89 352.8 15.89 403.6 17.89 454.4 19.89 505.2
Note: Special lengths available
B-Track k2x
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
14 356 16 406 18 457 20 508 22 559 24 610
A 21.89 556.0 23.89 606.8 25.89 657.6 30.89 784.6 32.89 835.4 34.89 886.2
Note: Special lengths available
4567
7 6 5 4 3 2
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2X Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Friday, October 21, 2005 7:41:48 AM
[148.88±0.43]5.861±.017
[78.23±0.38]3.080±.015
[109.76±0.30]4.321±.012
[39.12±0.13]1.540±.005
Ø 2.50 - .05+.01
63.5 - 1.3+0.3
6.969±.200[177±5.08]
[24.24±0.46].954±.018
[14.87±0.56].585±.022
[13.46±0.38].530±.015
50.80 +0.300
Ø 2.000 +-
.012
.000
[11.43±0.38].450±.015
[18.51±1.52].729±.06028.58 -
00.08
Ø 1.125 +-
.000
.003
[25.40±0.38]Ø 1.000±.015
12.9312.78
Ø .509.503
[ ]
[ ][ ]
[ ]
10" [254] LEAD WIRE LENGTH CONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATOR PACKARD 56 CONNECTOR
WIRES PROTECTED WITHBLACK SPIRAL WRAP
["A"±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31] LONGER THAN ADVERTISED
TOLERANCE IS +.036/-.005 [+.91/-.13]
THRU
BOTH ENDS
(ROD)
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
40 .....P-1581-WL 2/16
B-Track K2xac
Rugged Duty Actuator AC Motor Ball Screw
Up to 2,000 lbs. (8900 N) Rated LoadUp to 2.1 in. (53.34 mm)/sec. Travel Speed
The K2x model provides the highest load rating in its class. This model incorporates all of the base K2 features with a ball nut screw for a 2,000 lb. (8900 N) load capability within a compact package size. The K2x includes a bi-directional wrap spring brake for load holding capability. These units are well suited for the most demanding applications where an alternative to hydraulic or air cylinders is needed or where hydraulic power sources are not available.
Combining the K2x actuator with BTc control functionality results in precision actuator control at a fraction of the cost of more complicated servo actuator systems. See Controls Section for more information on BTc controls.
Now Available Optional Adjustable Limit Switch These easy to use adjustable switches are mounted in a channel on the cover tube with custom cap for protection. They are easily moved to enable the end-user the flexibility of setting the stroke length at any position within the full stroke capability.
Features • Protective coatings and O-ring seals
throughout• Efficient in-line ball screw system• Integral load holding brake• Ball detent over load clutch • Stroke lengths 4 to 24 inches (100 to 600
millimeters)• Load capacities up to 2,000 pounds
(8900 N)• Speeds up to 2.1 inches
(53.34 millimeters)/sec. travel• Thermal overload incorporated
into the motor• Heavy wall construction• Double ball bearing motors • Heat treated gears• Rugged extension rod bearing support• Custom mounting options available• Limit switches offered only in the
adjustable version (EP1.x)
Typical Applications• Engine Lifts• Tables• Indoor Applications• Machine Tools• Egg Rotation
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for load/current/speed capabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (IP 54 capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 110-240 VAC
• 14 gauge stranded lead wires-UL style 1230 w/PVC insulation Class F 105° C
• Use momentary contact switch in powering unit for extend/retract operation. (ON)-OFF-(ON) SPDT
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
*UL Certification, consult factory
*
Scan to watch!
How to Adjust the Limit Switches for a K2 or K2X Actuator with External or EP Limit Switches https://p.widencdn.net/imzc9v
ARTEN Freios e Embreagens - Fone: 11 5594-8333
41P-1581-WL 2/16....6
B-Track K2xac
1.2
1.3
1.4
1.5
1.6
1.7
1.8
2
2.25
2.5
2.75
3
3.25
0 100 200 300 400 500
K2XG05-115VAC Nominal Performance
Current Draw Speed
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
0 100 200 300 400 500
K2XG05-230VAC Nominal Performance
Current Draw Speed
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
0 200 400 600 800 1000
K2XG10-115VAC Nominal Performance
Current Draw Speed
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
1.2
1.25
1.3
1.35
1.4
1.45
1.5
1.55
0 200 400 600 800 1000
K2XG10-230VAC Nominal Performance
Current Draw Speed
0.49
0.5
0.51
0.52
0.53
0.54
0.55
0.56
2.35
2.4
2.45
2.5
2.55
2.6
2.65
2.7
0 250 500 750 1000 1250 1500
K2XG20-115VAC Nominal Performance
Current Draw Speed
0.49
0.5
0.51
0.52
0.53
0.54
0.55
0.56
1.18
1.21
1.24
1.27
1.3
1.33
1.36
0 250 500 750 1000 1250 1500
K2XG20-230VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
2.25
2.3
2.35
2.4
2.45
2.5
2.55
0 250 500 750 1000 1250 1500 1750 2000
K2XG30-115VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
1.14
1.16
1.18
1.2
1.22
1.24
1.26
1.28
0 250 500 750 1000 1250 1500 1750 2000
K2XG30-230VAC Nominal Performance
Current Draw Speed
k2xG05-115vac
k2xG10-115vac
k2xG20-115vac
k2xG30-115vac
k2xG05-230vac
k2xG10-230vac
k2xG20-230vac
k2xG30-230vac
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Spee
d -
IPS
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load - lbs
Load Capacity 1000 lbs.
Load Capacity 1500 lbs.
Load Capacity 2000 lbs.
Load Capacity 500 lbs.
SpeedCurrent Draw
Performance Graphs ImperialMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 42.
For Metric Measurements, see page 42.
For Metric Measurements, see page 42.
For Metric Measurements, see page 42.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
42 .....P-1581-WL 2/16
B-Track K2xac
32.5
35
37.5
40
42.5
45
2
2.25
2.5
2.75
3
3.25
0 445 890 1335 1780 2225
K2XG05-115VAC Nominal Performance
Current Draw Speed
32.5
35
37.5
40
42.5
45
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
0 445 890 1335 1780 2225
K2XG05-230VAC Nominal Performance
Current Draw Speed
0.49
0.5
0.51
0.52
0.53
0.54
0.55
0.56
2.35
2.4
2.45
2.5
2.55
2.6
2.65
2.7
0 250 500 750 1000 1250 1500
K2XG20-115VAC Nominal Performance
Current Draw Speed
0.49
0.5
0.51
0.52
0.53
0.54
0.55
0.56
1.18
1.21
1.24
1.27
1.3
1.33
1.36
0 250 500 750 1000 1250 1500
K2XG20-230VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
2.25
2.3
2.35
2.4
2.45
2.5
2.55
0 250 500 750 1000 1250 1500 1750 2000
K2XG30-115VAC Nominal Performance
Current Draw Speed
0.34
0.35
0.36
0.37
0.38
0.39
0.4
1.14
1.16
1.18
1.2
1.22
1.24
1.26
1.28
0 250 500 750 1000 1250 1500 1750 2000
K2XG30-230VAC Nominal Performance
Current Draw Speed
k2xG05-115vac
k2xG20-115vac
k2xG30-115vac
k2xG05-230vac
k2xG20-230vac
k2xG30-230vac
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PS
Spee
d -
MM
PSSp
eed
- M
MPS
Spee
d -
MM
PS
Load - N
Load - N
Load - N
Load - N
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
0 200 400 600 800 1000
K2XG10-115VAC Nominal Performance
Current Draw Speed
0.94
0.96
0.98
1
1.02
1.04
1.06
1.08
1.2
1.25
1.3
1.35
1.4
1.45
1.5
1.55
0 200 400 600 800 1000
K2XG10-230VAC Nominal Performance
Current Draw Speed k2xG10-115vac k2xG10-230vac
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
MM
PS
Spee
d -
MM
PS
Load - N Load - N
Load - N
Load - N
Load Capacity 4450 N
Load Capacity 6675 N
Load Capacity 8900 N
Load Capacity 2225 N
Performance Graphs Metric SpeedCurrent DrawMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 41.
For Imperial Measurements, see page 41.
For Imperial Measurements, see page 41.
For Imperial Measurements, see page 41.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
43P-1581-WL 2/16....6
B-Track K2xac
Dimensions
B-Track K2xac
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
4 100 6 150 8 200 12 300 18 450 24 600
A 14.96 380.0 16.97 431.0 18.94 481.1 22.95 582.9 28.94 735.1 34.92 887.0
Note: Special lengths available
145678
8 7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:2
SIZE PART NUMBERC
REV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2XAC Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
NW
Friday, October 21, 2005 7:41:48 AM
6.157±.017[156.39±0.43]
3.080±.015[78.23±0.38]
[39.12±0.13]1.540±.005
[117.28±0.30]4.617±.012
12.625±.200[320.68±5.08]
.530±.015[13.46±0.38]
.585±.022[14.87±0.56]
.954±.018[24.24±0.46]
[25.40±0.38]Ø 1.000±.015
50.80+0.30
0
Ø 2.000 +-.012.000
86.9 +-0.31.3
Ø 3.42 +-.01.05
[11.11±0.38].438±.015
[31.30±1.52]1.232±.060
28.58 -00.08
Ø 1.125 +-.000.003
12.9312.78
Ø .509.503
[ ]
[ ]
[ ]
[ ]
(ROD)
23.5" [597] CABLE W/18AWG WIRESHOT TO RED WIRE TO EXTEND
HOT TO BLACK WIRE TO RETRACTWHITE WIRE IS NEUTRAL
GROUND TO GREEN WIRE
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091LONGER THAN ADVERTISED
TOLERANCE IS +.036/-.005 [+.91/-.13]
THRU
BOTH ENDS
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
44 .....P-1581-WL 2/16
Custom Actuators
Examples of special request features
Standard
63
4
1
57
2
Warner Linear offers a broad range of standard actuators to suit many needs. We realize though, that often special application parameters dictate special actuator configurations and modifications. Warner Linear actuators are designed with this in mind, as many of our products can be readily customized to suit specific requirements.
Our products are built on modules that can be mixed and matched in final assembly. Our final assembly operations are configured to provide flexible assembly to accommodate custom orders, quickly and cost effectively.
If your application has a special need that our standard catalog products are unable to fit, please contact your Warner Linear representative or consult with our technical specialists so we can configure a product to fit your need.
A few of our standard special offerings:
• Special pin to pin lengths and stroke lengths
• Special end fittings and mounting configurations
• Special paints and motor lead wire lengths and connectors
Rod End Mounting Option Examples(Available for B-Track models only, consult factory for more options)
Consult with factory for specific mounting configuration needs.
1. 1/2" Threaded rod end
2. 5/8" Threaded rod end
3. 1/2" Spherical rod end
4. 5/8" Spherical rod end
5. 1" Extended rod end
6. Flat sided rod end
7. 3/8" Rod end insert
B-Track Rod End Mounting Options
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
STANDARDRod End
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 1
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 2
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 3
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 4
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 5
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rod EndOption 6
Rod EndOption 7
Dimensions are in inches
THRUTHRU
THRU
THRU
THRU
DEEP
DEEP
THREADS
THREADS
1.36
1/2-20 UNF-2AX .88 DEEP
.509.503 THRU
.44
1.27
1.00
1.23
R.66
.50 THRU
3.04
1.36
1/2-20 THREADS
3.04
1.36
R.75
.63 THRU 5/8-18 THREADS
1.27
.44
.509
.503 THRU
1.00
1.20
1.36
5/8-18 UNF-2AX .75 DEEP
.53(2)
FLATS
.45
.72
.509.503 THRU
.38 THRU
.45
.72
STANDARDROD END
ROD ENDOPTION #1
ROD ENDOPTION #2
ROD ENDOPTION #3
ROD ENDOPTION #4
ROD ENDOPTION #5
ROD ENDOPTION #6
ROD ENDOPTION #7
D
C
B
A
B
C
D
678
8 7 6
W ARNER L INEAR
SCALE 1:2
SIZE DRAWING NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 3 OF 3
FINISH:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
WARNER LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFWARNER LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
CREATEDWednesday, August 18, 2010 10:35:10 AM
5 4 3 2 1
12345
A
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
THRU
FLATS
ARTEN Freios e Embreagens - Fone: 11 5594-8333
45P-1581-WL 2/16....6
.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø
.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø
Custom Actuator Solutions
We recognize how critical our actuators are to the overall performance of your equipment. Working closely with your engineering and development staff, we strive for an early understanding of how you want your linear actuator to perform.
Building a direct communication line from our engineer to your engineer provides a number of significant benefits.
• A teaming of creative resources
• Joint understanding of our actuator capabilities and how they can be tailored to your application
• An understanding of the lowest cost solution to meet your actuator requirements
• Providing a complete solution that includes controls as required
Warner Linear routinely provides actuators modified to meet specific customer application requirementsSome common versions of these are shown as our K2PL/
K2XPL and K2JS/K2XJS families.
Additional common modifications are:
D
C
B
AA
B
C
D
145678
8 7 6 5 4 3 2 1
E
F
E
F
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBER
CREV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
trunnnion mount
KODIAK ACTUATOR
DIMENSIONAL OUTLINE5/12/2010DS
5/12/2010TAJ
NW
Friday, October 21, 2005 7:41:48 AM
"XI"(Customer To Specify Full Retract)
Tube/Trunnion Mount
Modified Seal design for expanded contamination protection
Modified Seal
B-Track Base Clevis Options
STANDARDBase
FLATS ONBase
SPHERICALBase 1/2-20
THREADEDBase 1/2-20
THREADEDBase 5/8-18SPHERICAL
Base 5/8-18
EXTENDEDBase
BLUNTBase
Dimensions are in inches
.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø
THREADS
1.48
1/2-20 UNF-2AX .62 DEEP
1.48
5/8-18 UNF-2AX .62 DEEP
THREADEDBASE 1/2-20
THREADEDBASE 5/8-18
D
C
B
A
B
C
D
678
8 7 6
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 2 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
5 4 3 2 1
12345
A
DEEP
1.48
1/2-20 UNF-2AX .62 DEEP
1.48
5/8-18 UNF-2AX .62 DEEP
THREADEDBASE 1/2-20
THREADEDBASE 5/8-18
D
C
B
A
B
C
D
678
8 7 6
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 2 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
5 4 3 2 1
12345
A
DEEP
.95
1.48
Ø 1.00
Ø 1.00
Ø 1.00
.509.503
1.87
1.37
.67
3.17
3.83R.66
Ø .50
1.48
1/2-20 THREADS
Ø .59
1.67
1.17
3.36
Ø .63
R.75
1.48
5/8-18 THREADS
.53(2)
FLATS
STD BASE
EXTENDEDBASE
BLUNTBASE
FLATS ONBASE
SPHERICAL BASE 5/8-18
SPHERICAL BASE 1/2-20
BEAR LINEAR
SCALE 1:3
SIZE PART NUMBER
BREV.
UNLESS NOTED:DIMENSIONS ARE IN INCHESTOLERANCES: .XXX = +/-.005" & MAX FINISH 60 Ra .XX = +/-.010" & MAX FINISH 125 Ra .X = +/-.060" & MAX FINISH 250 Ra ANGULAR: +/- 3 GEOMETRIC TOLERANCING PER ANSI Y14.9BREAK ALL CORNERS .010" NO SHARP BURRS
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 3
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
Base Options
BASE CLEVIS OPTIONS
TAJJRZ 4/22/2014
NW
4/22/2014
Ø
THREADS
FLATS
ARTEN Freios e Embreagens - Fone: 11 5594-8333
46 .....P-1581-WL 2/16
B-Track K2pl / K2xpl
Power Lift Actuator DC Motor – Acme or Ball Screw
Up to 2,200 lbs. (9786 N) Rated LoadUp to 2.1 in. (53.34 mm)/sec. Travel Speed
B-Track Power Lift models are modified K2 or K2x actuators. Power Lift units utilize all the standard components and retain all the performance features of the K2 family, without the external cover tube. This allows the Power Lift actuator features to be integrated into a variety of customer designed structures, where a cover tube is not needed.
Extended gear box screws are provided allowing easy attachment to a customer frame. A straight through manual override option is available as shown above. Suggested for tension applications only. Consult factory for compression loading applications.
Shown with optional direct drive manual override feature without protective cap.
Features • Protective coatings and O-ring seals
throughout
• Efficient in-line load system
• Patented hybrid nut and screw design, no brake needed in K2 model
• Integral load holding brake on K2x model
• Ball detent over load clutch
• Stroke lengths 4 to 24 inches (100 to 600 millimeters)
• Load capacities up to 2200 pounds (9786 N)
• Speeds up to 2.1 inches (53.34 millimeters)/sec. travel
• Thermal overload incorporated into the motor
• Heavy wall construction
• Double ball bearing motors
• Heat treated gears
• Optional 90 vdc motor for use with SBC-AC control
• Custom mounting options available
Typical Applications • Wheelchair and scooter lifts
• Traffic signs
• Beds and tables
• Light masts
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for load/current/speed capabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
• (Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 10-16 vdc (Ratings are at 12 vdc Normal.)
• 14 gauge stranded lead wires-UL style 1230 w/PVC insulation Class F 105° C
• Lead wires abrasion protected with spiral covering
• Use momentary contact double pole/double throw switch in powering unit for extend/retract operation. (ON)-OFF-(ON) DPDT
• Connectors: - Packard 56 series or Delphi Weather-Pack - Packard 56 series with 56 series blades (#2984883 & #2962987) - Delphi Weather-Pack series (#121015792 & #12010973)
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
ARTEN Freios e Embreagens - Fone: 11 5594-8333
47P-1581-WL 2/16....6
B-Track K2PL / K2xPL
B-Track K2pl
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
4 102 6 152 8 203 10 254 12 305 14 356
A 7.03 178.6 9.03 229.4 11.03 280.2 13.03 331.0 15.03 381.8 17.03 432.6
Note: Special lengths available
Dimensions
Performance Graphs
See pages 29-30 for K2PL performance charts.See pages 37-38 for K2xPL performance charts.
B-Track K2pl
Stroke
in. mm in. mm in. mm in. mm in. mm
16 406 18 457 20 508 22 559 24 610
A 19.03 483.4 21.03 534.2 23.03 585.0 25.03 635.8 27.03 686.6
Note: Special lengths available
B-Track K2xpl
Stroke
in. mm in. mm in. mm in. mm in. mm in. mm
4 102 6 152 8 203 10 254 12 305 14 356
A 8.53 216.7 10.53 267.5 12.53 318.3 14.53 369.1 16.53 419.9 18.53 470.7
Note: Special lengths available
B-Track K2xpl
Stroke
in. mm in. mm in. mm in. mm in. mm
16 406 18 457 20 508 22 559 24 610
A 20.53 521.5 22.53 572.3 24.53 623.1 26.53 673.9 28.53 724.7
Note: Special lengths available
ARTEN Freios e Embreagens - Fone: 11 5594-8333
48 .....P-1581-WL 2/16145678
8 7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2XPL Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Friday, October 21, 2005 7:41:48 AM
[109.76±0.30]4.321±.012
[148.88±0.43]5.861±.017
[39.12±0.13]1.540±.005
[78.23±0.38]3.080±.015
[31.8]1.25
[63.5]2.50
[22.2].88
[44.5]1.75
Ø 2.50 - .05+.01
63.5 -1.3+0.3
7.274±.200[184.76±5.08]
[31.99]1.260
[11.43±0.38].450±.015
12.9312.78Ø .509
.503
[18.5].73
[62.6]2.46
[39.9]1.57
28.58 -00.08
Ø 1.125+-.000.003
[ ]
[ ][ ]
Dimensions
B-Track K2pl
B-Track K2pl / K2xpl
D
C
B
A
145678
8 7 6 5 4 3 2 1
E
F
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
REV.
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2PL Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
NW
Friday, October 21, 2005 7:41:48 AM
[109.76±0.30]4.321±.012
[148.88±0.43]5.861±.017
[39.12±0.13]1.540±.005
[78.23±0.38]3.080±.015
[31.8]1.25
[63.5]2.50
[22.2].88
[44.5]1.75
Ø 2.50 - .05+.01
63.5 -1.3+0.3
7.274±.200[184.76±5.08]
[31.99]1.260
[11.43±0.38].450±.015
12.9312.78
Ø .509.503
[18.5].73
[62.6]2.46
28.58 -00.08
Ø 1.125 +-
.000
.003
[ ]
[ ]
[ ]THRU
THRU
(ROD)
(ROD)
TYP
TYP
(MTG STUD)
(MTG STUD)
(MTG STUD)
(MTG STUD)
(MTG STUD)
(MTG STUD)
(MTG STUD)
MANUALOVER-RIDE3/8 HEXW/ PROTECTIVE CAP
MANUALOVER-RIDE3/8 HEXW/ PROTECTIVE CAP
WIRES PROTECTED WITHBLACK SPIRAL WRAP
WIRES PROTECTED WITHBLACK SPIRAL WRAP
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
4X #10-32 UNF-2BBOLTS FOR MOUNTINGINCLUDES LOCK NUTS
4X #10-32 UNF-2BBOLTS FOR MOUNTINGINCLUDES LOCK NUTS
B-Track K2xpl
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]LONGER THAN ADVERTISED
TOLERANCE IS +.036/-.005 [+.91/-.13]
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]LONGER THAN ADVERTISED
TOLERANCE IS +.036/-.005 [.91/-.13]
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
49P-1581-WL 2/16....6
B-Track K2js / K2xjs
Jack Stand Actuator DC Motor – Acme or Ball Screw
Up to 2,800 lbs. (12455 N) Rated LoadUp to 2.1 in. (53.34 mm)/sec. Travel Speed
Shown with optional switch box, direct drive
manual override, and footpad.
The B-Track Jack Stand actuator incorporates a large diameter extension rod providing the maximum offset load capability within the K2 family. The extension rod is slightly smaller than the cover tube and slides on Teflon
® bearings within the cover tube. This feature makes
the K2js suitable for high-load, free-standing use.
A number of mounting options are available including trunnion mounts, or with standard flange plate (as shown). These units can be customized with an integral switch box, direct drive manual override, or pivoting footpad.
Features • Protective coatings and O-ring seals
throughout
• Efficient in-line ball screw system
• Integral load holding brake on K2x model
• Ball detent over load clutch
• Stroke lengths 8 to 16 inches (200 to 400 millimeters)
• Load capacities up to 2,800 pounds (12455 N)
• Speeds up to 2.1 inches (53.34 millimeters)/sec. travel
• Thermal overload incorporated into the motor
• Heavy wall construction
• Double ball bearing motors
• Heat treated gears
• Rugged extension rod bearing support
• Custom mounting options available
Typical Applications • Trailer jack stands
• Trailer and vehicle outriggers
• Implement lifts
• Machine height adjustment
• Camper lifts
• Load Levelers
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for load/current/speed capabilities
• Stroke Length Tolerance: +/-.06” (1.52 mm)
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: +25% over rated dynamic load
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
(Load/stroke profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (IP 54 capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 10-16 vdc (Ratings are at 12 vdc Normal.)
• 14 gauge stranded lead wires-UL style 1230 w/PVC insulation Class F 105° C
• Lead wires abrasion protected with spiral covering
• Use momentary contact double pole/double throw switch in powering unit for extend/retract operation. (ON)-OFF-(ON) DPDT
• Connectors: Packard 56 series or Delphi Weather-Pack - Packard 56 series with 56 series blades (#2984883 & #2962987) - Delphi Weather-Pack series (#121015792 & #12010973)
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
ARTEN Freios e Embreagens - Fone: 11 5594-8333
50 .....P-1581-WL 2/16
B-Track K2js / K2xjs
4567
7 6 5 4 3 2
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2JS Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Friday, October 21, 2005 7:41:48 AM
[148.88±0.43]5.861±.017
[78.23±0.38]3.080±.015
[109.76±0.30]4.321±.012
[39.12±0.13]1.540±.005
Ø 2.50 - .05+.01
63.5 -1.3+0.3
6.969±.200[177±5.08]
[24.24±0.46].954±.018
[14.87±0.56].585±.022
[13.46±0.38].530±.015
[44.22±0.38]1.741±.015
12.9312.78
Ø .509.503
[19.1].75
[27.3]1.08
50.80 +0.300
Ø 2.000 +-
.012
.000
[25.40±0.38]Ø 1.000±.015
[ ][ ]
[ ]
145678
8 7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:1
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
SHEET 1 OF 1
COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2XJS Dimensions
KODIAK ACTUATOR
DIMENSIONAL OUTLINE3/17/2014JRZ3/17/2014TWC
Friday, October 21, 2005 7:41:48 AM
[148.88±0.43]5.861±.017
[78.23±0.38]3.080±.015
[109.76±0.30]4.321±.012
[39.12±0.13]1.540±.005
[13.10]4X Ø .516
[22.2].88
[44.5]1.75
[44.5]1.75
111.13 -00.38
Ø 4.375+-.000.015
Ø 2.50 - .05+.01
63.5 -1.3+0.3
[185.03±5.08]7.285±.200
[32.39]1.275
[23].91
[19.1].75
[27.2]1.07
50.80 +0.300
Ø 2.000 +-.012.000
12.9312.78Ø .509
.503
[44.22±0.38]1.741±.015
[177.80±0.38]7.00±.015
[ ]
[ ]
[ ]
[ ]
B-Track K2jS
B-Track K2xjS
Performance GraphsSee page 29-30 for K2JS performance charts.See page 37-38 for K2xJS performance charts.
Dimensions
B-Track k2jS/k2xjS
Stroke
in. mm in. mm in. mm in. mm in. mm
8 203 10 254 12 305 14 356 16 406
A 20.98 532.9 22.98 583.7 24.98 634.5 26.98 685.3 28.98 736.1
Note: Special lengths available
MANUALOVER-RIDE3/8 HEXW/ PROTECTIVE CAP
WIRES PROTECTED WITHBLACK SPIRAL WRAP
WIRES PROTECTED WITHBLACK SPIRAL WRAP
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
NON-ROTATING ROD
NON-ROTATING ROD
THRU
BOTH ENDS
THRU
THRU(BODY PROFILE)
(BODY PROFILE)
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]LONGER THAN ADVERTISED
TOLERANCE IS +/-.060 [+/-1.52]
["A" ±3.18]"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]LONGER THAN ADVERTISED
TOLERANCE IS +/-.060 [+/-1.52]
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
51P-1581-WL 2/16....6
B -Track K2ra
Rotary Actuator DC Motor
Features• Protective coatings and O-ring seals
throughout
• Efficient in-line load system
• Ball detent over load clutch
• Speeds up to 850 RPM
• Thermal overload incorporated into the motor
• Heavy wall construction
• Double ball bearing motors
• Heat treated gears
• Rugged output bearing support
• Customized mounting configurations available
• Optional 24 vdc motor available to provide more speed selections
Typical Applications • Salt/seed spreaders
• Scooter lift mechanisms
• Spout rotation
• Turntables
• Cable winch
• Maximum Static Rating: 3,000 lbs. (13345 N) Static (in-line load)
• Refer to performance chart for current/speed capabilities
• Motor is protected with auto reset breaker inside motor housing (temperature/current/time dependent)
• Overload clutch setting: match customer requirements
• Duty cycle is time/temperature/load dependent, suggested guidelines are: - 50% max on-time/50% off-time for loads up to 50% of capability - 25% max on-time/75% off-time for loads between 50%-80% of capability - 10% max on-time/90% off-time for loads between 80%-100% of capability
(Load/RPM profiles will allow some adjustment variation from these guidelines.)
• Ambient temp range: -20° F to +150° F (-29º C to +65º C), -40º F to +176º F (-40º C to +80º C) Upon Request.
• Weather resistant enclosure & seals (IP 65 capable, 250 hour salt spray, 500 hour for paint)
• Normal operating voltage: 12, 24, 36, 48 vdc (Ratings are at 12 vdc Normal.)
• 14 gauge stranded lead wires - SAE J1128 SXL cross linked polyethylene insulation Class F 257° F (125º C)
• Lead wires abrasion protected with spiral covering
• Use momentary contact double pole/double throw switch in powering unit. (ON)-OFF-(ON) DPDT
• Connectors: - Packard 56 series or Delphi Weather-Pack - Packard 56 series with 56 series blades (#2984883 & #2962987) - Delphi Weather-Pack series (#121015792 & #12010973)
Load/Current/Speed/Duty Cycle Operating Environment
Control/Connections
Up to 140 in.-lb. (16 Nm) Torque OutputSpeeds from 250 to 850 RPM
K2ra rotary actuators are motor driven gear boxes and use the base drive design and components of the K2 linear actuator. K2ra models incorporate all of the features of the K2 model providing excellent weatherproofing for outdoor applications. The same long-life motors, hardened gears, corrosion protection, and lubrication are utilized. Several output shaft and mounting configurations are available with the standard configuration shown above.
Shown with extended gear box screws for ease of attachment.
Optional Configurations
ARTEN Freios e Embreagens - Fone: 11 5594-8333
52 .....P-1581-WL 2/16
B -Track K2ra
k2raG05-12vDc
k2raG10-12vDc
k2raG20-12vDc
k2raG30-12vDc
k2raG05-24vDc
k2raG10-24vDc
k2raG20-24vDc
k2raG30-24vDc
400
500
600
700
800
900
0
5
10
15
20
25
0 5 10 15 20 25 30
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG05-12VDC Nominal Performance
Current Draw Speed
400
500
600
700
800
900
0
2.5
5
7.5
10
12.5
0 5 10 15 20 25 30
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load in-lbs Load in-lbs
150
200
250
300
350
400
450
0
5
10
15
20
25
0 10 20 30 40 50 60
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG10-12VDC Nominal Performance
Current Draw Speed
150
200
250
300
350
400
450
0
2.5
5
7.5
10
12.5
0 10 20 30 40 50 60
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG10-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load in-lbs Load in-lbs
100
125
150
175
200
225
0
5
10
15
20
25
0 20 40 60 80 100 120
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG20-12VDC Nominal Performance
Current Draw Speed
100
125
150
175
200
225
0
2.5
5
7.5
10
12.5
0 20 40 60 80 100 120
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG20-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load in-lbs Load in-lbs
30
50
70
90
110
130
150
0
5
10
15
20
25
0 20 40 60 80 100 120 140 160 180
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG30-12VDC Nominal Performance
Current Draw Speed
30
50
70
90
110
130
150
0
2.5
5
7.5
10
12.5
0 20 40 60 80 100 120 140 160 180
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load in-lbs
K2RAG30-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load in-lbs Load in-lbs
Load Capacity 60 in-lbs.
Load Capacity 120 in-lbs.
Load Capacity 180 in-lbs.
Load Capacity 30 in-lbs.
Performance Graphs Imperial Speed Current DrawMeasurements*
*Performance Chart Measurements are Nominal
For Metric Measurements, see page 53.
For Metric Measurements, see page 53.
For Metric Measurements, see page 53.
For Metric Measurements, see page 53.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
53P-1581-WL 2/16....6
B -Track K2ra
k2raG05-12vDc
k2raG10-12vDc
k2raG20-12vDc
k2raG30-12vDc
k2raG05-24vDc
k2raG10-24vDc
k2raG20-24vDc
k2raG30-24vDc
400
500
600
700
800
900
0
5
10
15
20
25
0.0 0.6 1.1 1.7 2.3 2.8 3.4
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG05-12VDC Nominal Performance
Current Draw Speed
400
500
600
700
800
900
0
2.5
5
7.5
10
12.5
0.0 0.6 1.1 1.7 2.3 2.8 3.4
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG05-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load N-m Load N-m
150
200
250
300
350
400
450
0
5
10
15
20
25
0.0 1.1 2.3 3.4 4.5 5.7 6.8
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG10-12VDC Nominal Performance
Current Draw Speed
150
200
250
300
350
400
450
0
2.5
5
7.5
10
12.5
0.0 1.1 2.3 3.4 4.5 5.7 6.8
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG10-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load N-m Load N-m
100
125
150
175
200
225
0
5
10
15
20
25
0.0 2.3 4.5 6.8 9.0 11.3 13.6
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG20-12VDC Nominal Performance
Current Draw Speed
100
125
150
175
200
225
0
2.5
5
7.5
10
12.5
0.0 2.3 4.5 6.8 9.0 11.3 13.6
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG20-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load N-m Load N-m
30
50
70
90
110
130
150
0
5
10
15
20
25
0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG30-12VDC Nominal Performance
Current Draw Speed
30
50
70
90
110
130
150
0
2.5
5
7.5
10
12.5
0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3
Spee
d -
RPM
Curr
ent D
raw
- A
mps
Load N-m
K2RAG30-24VDC Nominal Performance
Current Draw Speed
Curr
ent D
raw
- A
mps
Curr
ent D
raw
- A
mps
Spee
d -
RPM
Spee
d -
RPM
Load N-m Load N-m
Load Capacity 6.8 N-m
Load Capacity 13.6 N-m
Load Capacity 20.3 N-m
Load Capacity 3.4 N-m
Speed Current Draw
Performance Graphs MetricMeasurements*
*Performance Chart Measurements are Nominal
For Imperial Measurements, see page 52.
For Imperial Measurements, see page 52.
For Imperial Measurements, see page 52.
For Imperial Measurements, see page 52.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
54 .....P-1581-WL 2/16
Dimensions
B -Track K2ra
12345678
8 7 6 5 4 3 2 1
BEAR LINEAR
SCALE 1:1.5
SIZE PART NUMBERC
NAME DATE
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.COMMENTS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFBEAR LINEAR. ANYREPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFBEAR LINEAR IS PROHIBITED.
MATERIAL
TITLE
K2RA Dimensions
K2 ROTARY ACTUATOR
TAJ3/17/2014TWC
3/17/2014
3.080±.015[78.23±0.38]
5.861±.017[148.88±0.43]
2.50[63.5]
1.75[44.5]
[39.12±0.13]1.540±.005
[109.76±0.30]4.321±.012
Ø .751 [19.08] 1.000 [25.40]
Ø 1.123 - .003+.000
28.52- 0.08
0
Ø 2.50 - .05+.01
63.5 -1.3+0.3
Ø 2.000 - .000+.012
50.80 0+0.30
Ø 1.000±.015[25.40±0.38]
.65[16.5]
.44[11.1]
6.664[169.28]
.43[10.9]
Ø .250±.005 [6.35±0.13] 3.91
[99.3]
#10-32 [ ]
[ ][ ]
10" [254] LEAD WIRE LENGTHCONNECT (+) TO GRAY WIRE& (-) TO BLACK WIRE TO EXTENDTHE ACTUATORPACKARD 56 CONNECTOR
WIRES PROTECTED WITHBLACK SPIRAL WRAP
(MTG STUD)
(MTG STUD)
THRU
PILOT
STUDLENGTH
STUD4 PLACES
ALL DIMENSIONS ARE NOMINAL UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
55P-1581-WL 2/16....6
Warner Linear Actuator Controls available for a wide variety of applications
Warner Linear provides a full line of actuator controls well suited for a broad range of application needs.
They range from simple to use switch box controls for basic extend/retract function, to state-of-the-art microprocessor based digital electronic controls using SMT design and manufacturing processes.
Offered functions:
• Basic extend and retract
• Electric switch and electronic stroke limits
• End of stroke outputs
• Position feedback potentiometer and encoder outputs
• Electronic current limit – fixed and programmable
• Electronic dynamic braking
• Fixed, manual and electronic adjustable end stops
• Signal follower
Dependable OperationWarner Linear controls are state-of-the-art using surface mount electronic components and automated circuit board manufacturing methods. Each control is field durability tested for use in demanding applications.
Rugged and ReliableUse of SMT manufacturing processes assures consistent performance from control to control.
• Integrated actuator sensors are protected from the environment
• Solid-state electronic components and non-contact sensors (Hall effect)
• Actuator mounted or remote mountable
Easy To Use• Simple plug-and-play switch box controls are hassle-free – just plug in
and connect the power clips.
• Basic position controls are integrated with the actuators to simplify ease of use and maintain the rugged duty capabilities of Warner Linear actuators. They are easy to use and plug-and-play ready.
• Advanced microprocessor based controls are also available. They employ digital electronics using SMT processes and offer a broad range of intelligent actuator control options. Consult your Warner Linear technical specialist on how advanced controls might suit your needs.
Warner Linear BTc controls are specifically designed for use with the B-Track line of actuators. Some controls and options are also suitable for use with the M-Track models.
Performance Features
ARTEN Freios e Embreagens - Fone: 11 5594-8333
56 .....P-1581-WL 2/16
Power Supply/Control/Accessory Selection Guide
Customer Provides Power
Switch Box for 12, 24, or 48 volt motor actuators. . . . . . . . . . . . . . . . . . . . . Page 57 Input: 12ft. (3.66m) cable Output: 1ft. cable or optional cables (M1, K2, K2x, RA actuators)
Switch Box for 115 or 230 volt actuators. . . . . . . . . . . . . . . . . . . . . . . . . Page 57 Input: 6ft (1.83m) cable Output: Customer supplied connector (K2ac, K2xac actuators)
Power Supply Required
12 or 24 volt DC Power Supply for M-Track Actuator . . . . . . . . . . . . . . . . . . . Page 58 Options: AC input with plug AC input without plug Switch included Switch not included
90 volt DC Power Supply for K2/K2x Actuator . . . . . . . . . . . . . . . . . . . . . . Page 59 Options: AC input with plug AC input without plug Switch included Switch not included Speed Potentiometer
24 volt DC Power Supply for K2/K2x Actuator . . . . . . . . . . . . . . . . . . . . . . Page 60 Options: AC input with plug AC input without plug Switch included Switch not included
NOTE: All power supply designs are provided with a one foot long cable for connection to actuator. Accessory cables are available in lengths of 5, 10, 20, 25 foot (1.524, 3.048, 6.096, 7.62mm) length.
Controls
End of Travel Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 61-62 Factory set/not adjustable (P1) . . . . . . . . . . . . . . . . . . . . . Pages 63-64 Field Adjustable (EP1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 65
Quick Stop Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 66-67
Position Feedback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 68
Low Input Switching Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 69
Wireless Actuator Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 70
ARTEN Freios e Embreagens - Fone: 11 5594-8333
57P-1581-WL 2/16....6
Simple Switch Box Controls
SBC-DC
Power: Compatible with 12, 24 and 48 volt DC actuatorsFunction: Extend, Retract, Off via DPDT momentary toggle switchEnclosure: ABS plastic enclosure 4.7” L x 3.2” W x 2.2” H (119.38mm L x 81.28mm W x 55.88m H)Input Cable: 12ft. (3.66m), 2 wire, 14AWG cable with alligator clip endsOutput Cable: 1ft. (.30m) cable provided. Designate connector appropriate to actuator being used Optional extension cables are available in 5-25ft (1.524 - 7.62m) lengths
All actuators are controlled using an external-retract-off switching function. The SBC-DC and SBC-AC provide a simple mounted switch compatible with Warner Linear actuators.
SBC-AC Power: Compatible with 115 or 230 volt VAC inputFunction: Extend, Retract, Off via DPDT momentary contact switchEnclosure: 4.72” L x 4.72” W x 3.15” (119.89mm L x 119.89mm W x 80.01mm H) long dust tight
enclosureProtection: Externally mounted 5 Amp fuse on outside of enclosure for easy replacementInput Cable: 6ft. (1.829m) open ended tinned AC input cable providedOutput Cable: Sealed cable gland included for customer supplied output cable
Optional Extension and Control Power CablesPower supplies include a 1ft. (.30m) length cable to connect to actuator.
Accessory cables may be ordered in lengths of 5, 10, 20 and 25 feet (1.524, 3.048, 6.096 and 7.62 meters) with the appropriate connector for the actuator selected. (mini-packard, Packard 56, Weatherpack, Deutsch)
Live Power (LP) cables are required to provide constant power to BTc Limit switch or potentiometer feedback circuits mounted on the actuator. LP cables provide two connectors.
Signal Cables (SC) provide the LP cable with two additional connectors for use with limit switch or potentiometer feedback.
ASBC ––
SBC Model No.
AC
AC Input Power Input Wire Style
Blank– 6’ (1.829m) Open-ended (3) Strand WireA – 6’ (1.829m) Long 3 Prong Plug
3 10SBC ––
SBC Model No. Length of Mating Cable in Feet
(If blank, switch has no matingconnector)
DC
DC Input Power
Connector Style:
(One End Female Weatherpack)
Other End is Male Version of:
1 – Mini Packard 56 (M-Track)2 – Packard 563 – Weatherpack4 – Deutsch (DT06-2S)
ARTEN Freios e Embreagens - Fone: 11 5594-8333
58 .....P-1581-WL 2/16
M-Track Power SupplyExtension Cable Part Number
Input: 85-264 volts AC
Output: 12 volts @ 5.4Amps 24 volts @ 2.7Amps
Input Cable: Standard: 6ft. (1.829m) open end, tinned cable Optional: 6ft. (1.829m) with 115 VAC 3 prong plug
Output Cable: 1ft. (.30m) length cable with 2-pin Packard 56 (for M-Track 1) Optional extension cables can be ordered in 5-25ft. (1.524-7.62m) lengths
Enclosure: 4.72” x 4.72” x 3.15” (119.89mm L x 119.89mm W x 80.01mm H) polycarbonate housing NEMA 4, 4x, 12, 13
OperatingTemperature: -30º F to 140º F (-34º C to 60º C)
Ratings: CE, TUV, UL/cUL Conducted EMI meets EN55022 and ROHS
Protection: External fuse provided
Switching: No switch or DPDT momentary switch
Example:
Example:
SBC-AC Power Supply
PC Y3 20 (6.096)SBC – ––
SBC Model No.
12 & 24 Volt Model
Length in Feet (Meters)
2
Number of Conductors
Cable Type
PC – Power Cable (Carol “J” Cord with Shrink Sleeves)SC – Signal Cable (with Shrink Sleeves Only)LP – Live Power (22 AWG, 4 conductor wire but only use
red & black wires. Trim white & green wires flush with insulation.)
Dual Output “Y” Cable
(Used only on PC & LP options)
Connector Style:
One End Male, One End Female
1 – Mini Packard 56 (M-Track)2 – Packard 563 – Weatherpack4 – Deutsch (DT06-2S)
12V A S R1SBC –– –
SBC Model No.
AC Power SupplyReadout
R – 0-10V
Switch
S – Rocker SwitchBlank– No Switch
AC2
Input Power
AC – 115 VAC inputAC2 – 230 VAC input
Output Power
12V – 12VDC (M-Track Only)24V – 24VDC
Input Wire Style
Blank– 6' (1.829m) Open (3) Strand Wire
A – 6' (1.829m) Long 3 Prong Plug (Plug only available on 115 VAC input)
Connector Style:
(Female Gender)
1 – Mini Packard 56 (M-Track)
ARTEN Freios e Embreagens - Fone: 11 5594-8333
59P-1581-WL 2/16....6
K2/K2x Power SuppliesSBC-AC/SBC-AC2 Power Supply 90 volt output
Example: 90V A S P4SBC –– –
SBC Model No.
AC Power SupplyPotentiometer
P – Potentiometer (used for speed control)
Blank– No Potentiometer
Switch
S – Rocker SwitchBlank– No Switch
AC2
Input Power
AC – 115 VAC inputAC2 – 230 VAC input
Output Power
90V – 90VDC
Input Wire Style
Blank– 6' (1.829m) Open (3) Strand Wire
A – 6' (1.829m) Long 3 Prong Plug (Plug only available on 115 VAC input)
Connector Style:
(Female Gender)
4 – Deutsch DT06-3S
Input: AC: 115 volt ACAC2: 230 volt AC
Output: 90 volts DC @ 5 Amps
Input Cable: Standard: 6 ft. (1.829m) open end, tinned cableOptional for 115 AC 6 ft. (1.829m) with 115 VAC 3 prong plug
Output Cable: 1 ft. (.30m) cable with 3-pin Deutsch connectorOptional extension cables can be ordered in 5-25 ft. (1.524-7.62m) lengths
Enclosure: 4.72”L x 4.72”W x 3.15”H (119.89mm L x 119.89mm W x 80.01mm H) polycarbonate housing NEMA 4, 4x, 12, 13
Fusing: External fuse mounted on enclosure for easy replacement
Switching: DPDT momentary rocker switch for manual actuator control or Customer may supply their own switch
Potentiometer: Optional speed pot allows for output voltage adjustment (varies actuator speed)
ARTEN Freios e Embreagens - Fone: 11 5594-8333
60 .....P-1581-WL 2/16
K2/K2x Power SuppliesSBC-AC/SBC-AC2 Power Supply 24 volt output
Input: AC: 115 volt AC AC2: 230 volt AC
Output: 24 volts @ 12 Amps
Input Cable: Standard: 6 ft. (1.829m) open end, tinned cable Optional for 115 AC 6 ft. (1.829m) with 115 VAC 3 prong plug
Output Cable: Standard 1 ft. (.30m) cable: specify connector to match actuator:1. Mini Packard standard for M-Track actuators2. Packard 56 standard on K2 and K2x model actuators3. Packard WeatherPack optional on K2 and K2x model actuators4. Deutsch DT06-2S optional on K2 and K2x model actuators5. Optional extension output cables can be ordered in 5-25 ft.
(1.524-7.62m) lengths
Enclosure: 6.69”L x 6.69”W x 3.54”H (169.93mm L x 169.93mm W x 89.916mm H) polycarbonate housing NEMA 4, 4x, 12, 13
Fusing: External fuse mounted on enclosure for easy replacement
Switching: DPDT momentary rocker switch for manual actuator control or Customer may supply their own switch
Live Power Option: When used with BTc control options (limit switch, potentiometer
feedback) the Live Power option is required. Live power option provides a constant output power source for external control components regardless of output power to the actuator. (See Extension Cable selection to select the correct cable for this option.)
Example:
24V A SH L2SBC –– –
SBC Model No.
AC Power Supply
Live Power
(Required on P1.2 and P2.0 Control Systems)
Blank=No Live Power
Switch
S – Rocker SwitchBlank– No Switch
AC2
Input Power
AC – 115 VAC inputAC2 – 230 VAC input
Output Power
24V – 24VDC12V – 12VDC (S-Track
and I-Track Only)
Input Wire Style
Blank– 6' (1.829m) Open (3) Strand Wire
A – 6' (1.829m) Long 3 Prong Plug (Plug only available on 115 VAC input)
AMP Output
Blank– Standard 12 Amp OutputH – High Current 20 AMP Output
(Can run 2 actuators from same power supply. B-Track Only)
Connector Style:
(Female Gender)
2 – Packard 56 (B-Track)3 – WeatherPack (B-Track)4 – Deutsch DT06-2S (B-Track)5 – S-Track6 – I-Track
ARTEN Freios e Embreagens - Fone: 11 5594-8333
61P-1581-WL 2/16....6
Switch Only Units SO
Any of Warner Linear’s K2 or K2x actuators can be provided with Hall effect or reed switches to be used by the customer to control actuator start/stopping & positioning. The Hall effect and reed switches are both non-contact, and use a magnet mounted on the screw inside the actuator tube to activate. Actuators can have 2-4 switches dependent on stroke length.
Hall EffectThe Hall effect switch is an NPN output/current sinking and requires a pull-up resistor to operate.
The Hall effect switches can also be configured to provide positioning information. A ten tooth wheel with two switches is used to provide an A and B pulse for position and direction along with a home switch and fully extended switch. This unit would be a “SO4” configuration.
Hall Effect Switch Part Numbers Available, with K2 actuator product: SO2H – 2 end limit switches
Hall Effect Switch Part Numbers Available, with K2e or K2xe actuator product:SO2H – 2 end limit switchesSO3W – 2 wheel position switches & home end limit switchSO3H – 2 end & 1 mid limit switchesSO4W – 2 wheel position switches & 2 end limit switchesSO4H – 2 end & 2 mid limit switches
Note 1: Consult factory for other options if neededNote 2: Units with 3 switches can be no shorter than 4” and units with 4 switches can be no shorter than 6”.
Hall EffectSupply Voltage: 4.75 to 24 VDC
Output: Current sinking, max. of 25mA
Lead Wires: 24 AWG
Operating Temperature:
-40° C to +85° C
Protection: Reverse polarity protected
Housing: Rugged thermoplastic, sealed
ReedThe reed switch can only be provided on a K2e or K2xe actuator (adjustable unit). Switches can be selected as normally open (O) or normally closed (C).
Reed Switch Part Numbers Available, with K2e or k2xe actuator product only:SO2O – 2 Normally Open, adjustable reed switchesSO2C – 2 Normally Closed, adjustable reed switchesSO3O – 3 Normally Open, adjustable reed switchesSO3C – 3 Normally Closed, adjustable reed switchesSO4O – 4 Normally Open, adjustable reed switchesSO4C – 4 Normally Closed, adjustable reed switches Note 1: Consult factory for other options if neededNote 2: Units with 3 switches can be no shorter than 4” and units with 4 switches can be no shorter than 6”.
ReedSupply Voltage: Up to 200 VDC max. O switch
Up to 175 VDC max. C switch
Switching Current:
1.2 Amps max. O switch1.5 Amps max. C switch
Contact Rating: 10 Watts max. O switch5 Watts max. C switch
Lead Wires: 24 AWG
Operating Temperature:
-40° C to +105° C
Housing: Hermetically sealed
1K/5K ohm
1K/5K ohm
1K/5K ohm
1K/5K ohm
SO2H Hall Effect
SO2O Normally Open Reed
Pin 4: Green, Extended Output, 20mA max.
Pin 3: Red, Supply Power
Pin 2: White, Retract Output, 20mA max.
Pin 1: Black, Supply Ground
Pin C: Green, Extend Switch Output
Pin B: White, Retract Switch Output
Pin A: Black, Switch Inputs
Supply Power4.5 to 24VDC
SwitchCable
SwitchCable
Adjustable Switch
ConnectorDT04-3PDeutsch
ConnectorDT06-4SDeutsch
All dashed lines are customer supplied connections
ARTEN Freios e Embreagens - Fone: 11 5594-8333
62 .....P-1581-WL 2/16
P1.x Electronic Stroke Limit ControlStandard
The P1.x Limit Switch control provides end of travel positioning through the use of a Hall effect sensor and motor mounted relay.
Hall effect sensors are factory mounted within the actuator cover tube. The sensor position is set at the factory and is not field adjustable (See EP.1 for adjustable switch functions). The Hall effect sensors are sealed for life and are not subject to wear.
The Electronic Stroke control package consists of the Hall effect sensors and a motor mounted relay within an enclosure suited for harsh environments.
A Zener diode suppression is used on both input and outputs for added protection from electrical spikes. Unit reversing is achieved by reversing input power polarity to the motor.
2.62 (66.55)
9.10 (231.14)
ø
2.13 (54.10)ADDED TO MOTOR LENGTH
Power: 25 Amps max. @ 12 volts12.5 Amps max. @ 24 volts
OperatingTemperature: -20º F to +150º F (-29º C to 66º C)
P1.0 Standard Stoke Limit Control
P1.1 Same as P1.0 with two LEDs on the outside of the control module. LEDs indicate when end of travel has been reached.
P1.2 Same as P1.0 with two 12/24 volt, 0.5 Amps outputs that can be used to signal an external switch, relay, lamp or PLC input.
P1.2LE Two +5 VDC 25ma outputs plus a ground to provide a signal when end of travel is reached. This output can be used to power LEDs.
Specifications
Options
ARTEN Freios e Embreagens - Fone: 11 5594-8333
63P-1581-WL 2/16....6
BTc Controls P1-DCP1 Electronic Stroke Limit Control
Wiring Diagrams
P1 Module P1.0-DC12/24
Model Selection
Model No. Input Voltage
(vdc)
MaximumOutput Current
(Amps) Features
P1.0 (DC12) 12 25 Base = Electronic Stroke Limit with Electronic Dynamic Braking
P1.0 (DC24) 24 12.5 Base = Electronic Stroke Limit with Electronic Dynamic Braking
P1.1 (DC12) 12 25 Base & LED indicators on Housing
P1.1 (DC24) 24 12.5 Base & LED indicators on Housing
P1.2 (DC12) 12 25 Base & +12 vdc Outputs
P1.2 (DC24) 24 12.5 Base & +24 vdc Outputs
P1.2LE (DC12) 12 25 Base & LED Outputs +5 vdc
P1.2LE (DC24) 24 12.5 Base & LED Outputs +5 vdc
Note: For adjustable external end limits add E before P
Operation
When the “Customer Supplied Switch” is held in the direction allowing positive 12 or 24VDC to the gray wire and 12 or 24VDC ground to the black wire, the actuator will extend until it reaches the end of stroke. At the end of stroke, which is determined by the factory set location of the Hall effect switches inside the actuator cylinder, power will be removed to the actuator by the P1.0 control. The actuator will no longer move in that direction even if the customer supplied switch is held.
When the switch is held in the opposite direction so the positive lead of the 12 or 24VDC signal is on the black wire and the 12 or 24VDC ground is on the gray wire, the actuator will retract until it returns to the full home position which is determined by the factory set location of the second Hall effect switch.
If the actuator does not stop when at either end then something in the actuator or P1.0 control may be damaged. Please call the factory for further analysis.
The actuators are 100% tested before leaving the factory.
P1Control
Connector2-wire, 14awgPackard 56
SwitchMomentary DPDTCenter Off
Fuse24VDC 15A12VDC 30A
12 or 24VDCPower Supply
InputActuator Extend = Gray +, Black -Actuator Retract = Gray -, Black +
Gray
Black
All dashed lines are customer supplied connections
ARTEN Freios e Embreagens - Fone: 11 5594-8333
64 .....P-1581-WL 2/16
BTc Controls P1-DCP1 Electronic Stroke Limit Control
+ _
OperationWhen the “Customer Supplied Switch” is held in the direction allowing positive 12 or 24VDC to the gray wire and 12 or 24VDC ground to the black wire, the actuator will extend until it reaches the end of stroke. At the end of stroke the “Extend Output” (green wire) will have +12 or 24 Volts to ground, indicating it is at the end. This signal can be used to light a Lamp, signal a relay coil, or an isolated PLC input that only requires 500mA or less. This output will only be on as long as power is maintained from the “Customer Supplied Switch”.
However, if the output needs to be on even if the “Customer Supplied Switch” is not activated then the “Live Power input” can be used. This will provide power all the time for the output to remain on whenever the Actuator is at either travel end.
Apply +12 VDC (for 12VDC unit) or +24 VDC (for @24VDC unit) to the red wire of the Deutsch (DT04-4P) 4 pin connector and ground to the black wire. This supply needs to be the same supply as the actuator and will require less than 500mA.
When the switch is held in the opposite direction so the positive lead of the 12 or 24VDC signal is on the black wire and the 12 or 24VDC ground is on the gray wire, the actuator will retract until it returns to full home position. At the full home position, the “Retract Output” (white wire) will have +12 or 24 volts to ground.
CAUTION Do not reverse polarity at live power input (i.e. 22GA red & black wires) or damage will occur.
Pin 1 Black Ground
P1.2Control
Fuse24VDC 15A12VDC 30A
Fuse1 Amp
Extend LampRelay or Isolated
PLC Input
Retract LampRelay or Isolated
PLC Input
Pin 2 White +12v or 24V Retract Output
Pin 3 Red +12V or 24V Live Power Input
Pin 4 Green +12V or 24V Extend Output
Gray
Gray + Ext
Gray + Ret
Black -
ConnectorDT04 - 4PDeutsch
Power Supply12 or 24VDC
Input
Connector14-2 AWGPackard 56
SwitchMomentary DPDTCenter Off
All dashed lines are customer supplied connections
ARTEN Freios e Embreagens - Fone: 11 5594-8333
65P-1581-WL 2/16....6
The EP1.x Limit Switch control provides end of travel positioning through the use of a magnetic switch and motor mounted relay.
The EP1 limit switches are mounted in a channel on the actuator cover tube accessible below a durable cover. (For factory set limit switches see P1.0 designs). The EP1 switches are field adjustable.
The Electronic Stroke control package consists of the magnetic sensors and a motor mounted relay within an enclosure suited for harsh environments.
A Zener diode suppression is used on both input and outputs for added protection from electrical spikes. Unit reversing is achieved by reversing input power polarity to the motor.
EP1.x Electronic Stroke Limit Control
2.62 (66.55)
9.10 (231.14)
ø
2.13 (54.10)ADDED TO MOTOR LENGTH
SpecificationsPower: 25 Amps max. @ 12 volts
12.5 Amps max. @ 24 volts
OperatingTemperature: -20º F to +150º F (-29º C to 66º C)
OptionsEP1.0 Standard Stoke Limit Control
EP1.1 Same as P1.0 with two LEDs on the outside of the control module. LEDs indicate when end of travel has been reached.
EP1.2 Same as P1.0 with two 12/24 volt, 0.5 Amps outputs that can be used to signal an external switch, relay, lamp or PLC input.
EP1.2LE Two +5 VDC 25ma outputs plus a ground to provide a signal when end of travel is reached. This output can be used to power LEDs.
EP1.4 Same as P1.0, end limit stopping with 0-10K ohm potentiometer output.
EP1.5 End limit stopping with end limit outputs and 0-10K potentiometer outputs.
Scan to watch!
How to Adjust the Limit Switches for a K2 or K2X Actuator with External or EP Limit Switches https://p.widencdn.net/imzc9v
ARTEN Freios e Embreagens - Fone: 11 5594-8333
66 .....P-1581-WL 2/16
Controls PQSPQS Quick Stop Control
Adjusting Extend &/or Retract Trip Current
• Remove access plugs on the side of control.
• Rotate trim pot counter clockwise for min. load.
• Rotate trim pot clockwise for max. load.
• Adjust the Retract pot to control closing force.
• Adjust the extend pot to control lifting force.
• Adjust as viewed with extension rod pointing up.
• Reinstall access plugs.
2.62 (66.55)
9.10 (231.14)
ø
2.13 (54.10)ADDED TO MOTOR LENGTH
Electric Rating & Model Selection
Model No. Input Voltage
(vdc)
MaximumOutput Current
(Amps) Features
PQS-12V 12 25Base = Electronic Stroke Limit with mid-stroke current limit and Electronic Dynamic Braking
PQS-24V 24 12.5
PQS.2-12V 12 25 Base & +12VDC Trip Outputs
PQS-24V 24 12.5 Base & +24VDC Trip Outputs
The PQS is a bi-directional current limit control. The control monitors current during actuator motion and quickly stops the actuator if an object gets in the way or at the end of stroke. The actuator will remain off until power is reapplied. The current limit setting is adjustable with two potentiometers that are accessible through two plugged holes on the side of the housing.
FeaturesQuick Stop: Field adjustable potentiometers limit the amount of current through the motor in one or both directions. Both potentiometers are factory set to the maximum actuator current unless otherwise specified. Potentiometers field adjustable also.
Motor Power: Switched by on board relay. The relay allows power to the motor as long as the actuator is not being commanded to go past the end limits.
Faster Stopping: Electronic dynamic braking, (EDB) is applied after every move for more accurate and faster stops.
Load Limit Trip Outputs: These outputs indicate when the current limit has been exceeded in either direction. They are active low transistor outputs.
Enclosure: Attaches to back of motor or other surface and is potted to work in harsh environments.
Protection: Zener diode suppression on the input and output for extra protection in noisy environments.
SpecificationsSupply Power: 12 or 24 VDC
Maximum Current
25 Amps @ 12VDC / 12.5 Amps @ 24VDC (at 25% duty cycle)
OperatingTemperature: -20° F to +150° F (-29° C to +66° C)
- +
RETRACTEDFORCEADJUST
LOAD
EXTENDEDFORCEADJUST
ARTEN Freios e Embreagens - Fone: 11 5594-8333
67P-1581-WL 2/16....6
+
–
PQS-12V/24V Module
PQS.2-12V/24V Module
Fuse24VDC 15A12VDC 30A
Fuse24VDC 15A12VDC 30A
Gray
Gray
Black
Black
PQSControl
PQSControl
12 or 24VDCPower Supply
Input
12 or 24VDCPower Supply
Input
Extend LampRelay, or isolated
PLC input
Extend LampRelay, or isolated
PLC input
Connector2-wire, 14awgPackard 56
Connector2-wire, 14awgPackard 56
SwitchMomentary DPDTCenter Off
SwitchMomentary DPDTCenter Off
Actuator Extend = Gray +, Black -Actuator Retract = Gray -, Black +
Load Limit Trip Output Wiring-outputs are active low
Pin 4: Green, Extend Load Limit Trip Output, 150mA max.
Pin 3: Red, Supply Power + (12VDC or 24VDC)
Pin 2: White, Retract Load Limit Trip Output, 150mA max.
Pin 1: Black, Supply Power Ground
All dashed lines are customer supplied connections
All dashed lines are customer supplied connections
Controls PQSPQS Quick Stop Control
Wiring Diagrams
ConnectorDT04-4PDeutsch
+
–
– +
– +
ARTEN Freios e Embreagens - Fone: 11 5594-8333
68 .....P-1581-WL 2/16
BTc Controls P2-DCP2-DC Position Feedback Control
Model Selection
Model No. Input Voltage
(vdc)
MaximumOutput Current
(Amps) Features
P2.0 (DC12) 12 25 Base = Electronic Stroke Limits with 0 to + 10V Analog Output and EDB
P2.0 (DC24) 24 12.5 Base = Electronic Stroke Limits with 0 to + 10V Analog Output and EDB
2.62 (66.55)
9.10 (231.14)
ø
2.13 (54.10)ADDED TO MOTOR LENGTH
Wiring DiagramP2 Module
P2.0-DC12/24
SpecificationsSupply Power: 25 Amps max. @ 12 volts
12.5 Amps max. @ 24 volts
OperatingTemperature: -20º F to +150º F (-29º C to 66º C)
Protection: Zenerdiode suppression on the input and output for protection from electrical noise.
+ _
Fuse24VDC 15A12VDC 30A
Power Supply12 or 24VDC
Input
Gray +
P2Control
ConnectorDT04-6PDeutsch
Connector14-2 AWGPackard 56
SwitchMomentary DPDTCenter OffBlack -
Fuse1 Amp
Gray + ExtGray - Ret
Pin 5 Blue +0 - 1V
Pin 4 Green No Connection
Pin 3 Red +12 or 24VDC
Pin 2 White No Connection
Pin 1 Black Ground
Pin 6 Orange 0 - 10V
Isolated PLC InputOr Other Device
All dashed lines are customer supplied connections
The P2.0 Position Control is a microprocessor position feedback control providing a 0-10 volt DC output indicating actuator travel. The control uses two inductive pulse count sensors and a counting wheel to accurately determine actuator position. A third sensor at the full retract position provides a zero or home position indication.
Hall effect limit switches (those used in the P1.0 control) are used to provide end of travel positioning and will shut off the actuator at both full extend and retract settings. All sensors are non-contact and sealed for life. They are integrated within the actuator and control to protect them from contamination.
Live power is needed to maintain the 0-10VDC analog output signal even when the “Customer Supplied Switch” is not activated. This feature has to be connected to ensure position is saved. The power has to be the same as the switched power supplied to the actuator and requires less than 100mA.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
69P-1581-WL 2/16....6
SpecificationsMain Power Input: 12 VDC
Main Input Current: 25 Amps (at 25% duty cycle)
OperatingTemperature: -20° F to +150° F (-29° C to 66° C)
Auxiliary 12V Power Output: 12VDC
Low Input Switching Current: 67mA
BTc Controls RPRP Low Input Switching Control
Control OperationApply 12 VDC to the main power input. Use the same 12 VDC supply to apply positive voltage to the orange wire to extend the actuator rod. When done extending, remove the positive 12 VDC from the orange wire and apply to the green wire to retract the actuator.
The auxiliary power output is used to power additional 12VDC items as needed. The power is the same as the “Main Power Input” applied by the customer to the 2-pin Packard 56 connector. The total power available is based on the customer supplied Power Input provided. The fuse should then be sized to 135% of the total power needed.
Typical Wiring
All dashed lines are customer supplied connections
Auxiliary 12V Power Output
Extend
Retract
2-pin Packard 56Connectors
Green - RetOrange - Ext
Red +Black -
Actuator Extend = Orange +12VDCActuator Retract = Green +12VDC
Fuse12VDC 30A
12 VDC PowerSupplyInput
This control provides the switching logic to use low current signal inputs for extending and retracting the actuator rod/screw. It mounts on the back end of Warner Linear’s 12VDC B-Track motor/actuator product.
ARTEN Freios e Embreagens - Fone: 11 5594-8333
70 .....P-1581-WL 2/16
Warner Linear’s wireless actuator control can be used to remotely control a 12 or 24VDC actuator up to 100 ft. away. It can be used with our standard line of P1 end limit controls. The unit is offered in a single and dual actuator output for the 12VDC unit. The 24VDC unit is only available with two actuator outputs. All models have a manual override feature to operate the actuator without a remote. The wireless system is an RF design operating at 915MHz.
One remote is provided with the receiver unit, but the receiver can have up to four remotes programmed to work with it.
SBC-S12V-WR
Typical Wiring
Actuator Extend = Gray +, Black -Actuator Retract = Gray -, Black +
Connector2-wire, 14awgPackard 56
Power SupplyInputGray
Black
Fuse24VDC 15A12VDC 30A
SpecificationsPower: 12/24 VDC
Maximum Current: 20 Amps single, 10 Amps dual
OperatingTemperature: -20º F to +150º F (-28º C to 66º C)
OperatingFrequency: 915 MHz
Enclosure: IP67
ReplaceableRemote Battery:
CR2032, life expectancy dependent on use, but should last approx. 2 years
Models AvailableSBC-S12V-WR: 20 Amp, Single Output
SBC-D12V-WR: 10 Amp, Dual Output
SBC-D24V-WR: 10 Amp, Dual Output
SpecificationsDual Output: SBC-DWT
Remote Lanyard: 059-0200-50
Remote Holder w/ Clip: SBC-HDR
Connector: Delphi 135 21467 for single output Tyco 350735-1 for dual output
All dashed lines are customer supplied connections
Wireless Actuator Control
ARTEN Freios e Embreagens - Fone: 11 5594-8333
71P-1581-WL 2/16....6
Warner Linear actuators are quickly and easily mounted by slipping pins through the holes at each end of the unit and into the brackets on the machine frame and load to be moved.
Use of solid pins provide maximum holding capability with a retaining ring or cotter pin on each end to prevent the solid pin from falling out of the mounting bracket (it is best to avoid roll pins and spring pins).
Mounting pins must be parallel to each other as shown above. Pins which are not parallel can cause excess vibration or actuator binding.
Loads should act along the axis of the actuator. Off-center loads may cause binding and lead to premature unit failure.
Ensure that mounting pins are supported at both ends. Cantilevered mounting is unacceptable. Failure to provide proper support will shorten unit life.
Do not attempt to mount M-Track actuators by the cover tube. The tube is not designed to support the forces required for tube mounting.
All actuator mounting supports must be capable of withstanding the load and torque developed when the unit extends or retracts. Restraining torque values are also provided with the details on each unit.
M-Track Torque created 20 inch pounds (2.3 Nm)All others Torque created 100 inch pounds (2.3 Nm)
X
X
General Mounting Information
Load
Right
Yoke MountCantilever
Mount
Right
Wrong
Wrong
ActuatorAxis
Load
Scan to watch!
Proper Steps and Best Practices for Mounting of Warner Linear Actuators Video https://p.widencdn.net/k3etry
ARTEN Freios e Embreagens - Fone: 11 5594-8333
72 .....P-1581-WL 2/16
Glossary
Axial load A load along the axis of the actuator screw (see figure 1).
Back driveForce applied on a ball bearing nut that causes rotational torque to reverse direction. A force sufficient to cause a unit to change direction.
BTc B-Track control family.
Cantilevered mount A mounting where the mounting pin is not supported on both sides. Cantilevered mounts are common causes of failure (see figure 2).
Clevis mount A U-shaped metal piece that has the ends drilled to accept a pin or bolt (see figure 3).
Compression load Compression loading will press on the unit (see figure 4).
Cover tube The outer tube or cover that encloses the screw and extension tube for an actuator.
Current vs. load The load on the motor is measured by amperes (current). Current draw will increase as load increases.
Cycle Movement from a fully retracted to fully extended position and back to fully retracted.
Duty cycle The amount of ‘on-time’ vs total time. A 25% duty cycle means that a unit operates for 10 seconds out of 40 seconds, or 4 seconds out of 16 seconds.
Eccentric load An off-center load which may cause binding and shorten actuator life (see figure 5).
End play The amount of backlash or movement between the extension tube and the body of the actuator.
Extension rate The rate of speed at which the actuator extends or retracts. This will vary based on loading (impact of load on speed is greater on DC units than on AC units).
Efficiency Ratio of input power to output power.
ESL Electronic Stroke Limit magnetically activated Hall effect switches that turn power off at end of stroke.
Figure 1 Axial load
Figure 3 Clevis mount
Figure 5 Eccentric load
Figure 6 Extended length
Figure 4 Compression load
Figure 2 Cantilevered mount
Load
Right Wrong
ActuatorAxis
Load
COMPRESSIONLOAD
ARTEN Freios e Embreagens - Fone: 11 5594-8333
73P-1581-WL 2/16....6
Extended length The overall length of the actuator from the center of the rear clevis to the center of the extension tube pin hole when the unit is at full extension (see figure 6).
Load The force, measured in pounds, that is applied as an axial load on the actuator.
Load holding The ability of the actuator to hold a load stationary when power is off.
Peak load The maximum dynamic load that will be applied to the actuator, or that the actuator is capable of moving.
Pin mount The use of a dowel or pin through the hole in the clevis mount (on the rear of an actuator) or the extension tube (on the front of an actuator) (see figure 7).
Radial load A load applied to the side of the extension tube or across the body of the actuator. Normally radial loading will have a negative impact on unit life (see figure 8).
Restraining torque The torque required to prevent torque within the unit from causing rotation on the body or extension tube of the unit (see figure 9).
Retracted length The overall length of the actuator from the center of the rear clevis to the center of the extension tube pin hole when the unit is at full retracted position (see figure 10).
Side load See radial loading (see figure 8).
Static load The maximum non-operating (or non-moving) load. Static load is the load holding capability of an actuator.
Synchronous position Having more than one actuator extend and retract together maintaining ± 0.20 position relative to each other.
Tension load A load that will tend to pull on the unit (see figure 11).
Thermal overload A switch within the motor that will open if the motor exceeds a predetermined heat level.
Figure 8 Radial load also side loading
Figure 9 Restraining torque
Figure 10 Retracted length
Figure 7 Pin mount
X
X
Figure 11 Tension load
Glossary
TENSIONLOAD
ARTEN Freios e Embreagens - Fone: 11 5594-8333
Other product solutions fromAltra Industrial MotionOur comprehensive product offering is comprised of nine major categories including electromagnetic clutches and brakes, heavy duty clutches and brakes, overrunning clutches, gearing, engineered couplings, engineered bearing assemblies, linear products and belted drives. With thousands of product solutions available, Altra provides true single source convenience while meeting specific customer requirements. Many major OEM’s and end users prefer Altra products as their No.1 choice for performance and reliability.
Linear Products
Warner Linear
Engineered Bearing Assemblies
Kilian Manufacturing
Precision Couplings and Air Motors
Huco Dynatork
Belted Drives and Sheaves
TB Wood’s
Heavy Duty Clutches and Brakes
Wichita ClutchTwiflex LimitedIndustrial ClutchSvendborg Brakes
Electromagnetic Clutches and Brakes
Warner ElectricInertia DynamicsMatrix International
Overrunning Clutches
Formsprag ClutchMarland ClutchStieber Clutch
Engineered Couplings and Universal Joints
TB Wood’sAmeridrives CouplingsAmeridrives Power TransmissionBibby Turboflex Lamiflex CouplingsGuardian Couplings
Gearing
Boston GearNuttall GearDelroyd Worm GearBauer Gear Motor
The power of one, the strength of many.
www.altramotion.com