1
Dental implants MPI 4
MPI Excellence® System 6
Advantages 8
Conical Internal Connection Conical Seal 10
- Prosthetic Components Conical CM 14
- Prosthetic Components for Digital Solutions 26
Abutments screws 28
Surgical material 29
- Dental cases 30
- Dental drills 32
- Screwdrivers and surgical instruments 34
General information 36
- Package opening instructions 38
- Label symbology 39
- Recommended implant position 40
- Quality and general terms of sale 42
2 3
Form Follows Function
Louis Sullivan
“It is the pervading law of all things organic and inorganic, of all things physical and metaphysical, of all things human and all things superhuman, of all true manifestations of the head, of the heart, of the soul, that the life is recognizable in its expression, that form ever follows function. This is the law.”
4 5
Medical Precision Implants, designed by professionals for professionals.
As a German partner of reference, we implement the state-of-the-art technology to our MPI Privilege® Implant System, creating and developing dental implants with the highest performance. directly through the practical experience of our professionals.
Our exclusive know-how based on the experience of our fi rst level professsionals, provides our dental implants with the utmost versatility and functionality present on the market.
Our cero defect policy, granted through our strict quality control procedures in the design and along the whole production chain, makes of our dental implants the security and harmony of our professionals, your security.
Developing close and communicative relationships with our clients, based on their constructive feedback of needs, makes us able to give effi cient solutions directly through the practical experience of our professionals.
MPI Privilege® System, the commitment in excellence which we all are searching for.
Evolution towards perfectionMPI Implant Systems
6 7
MPI Excellence®System
The conical confi guration has proven for their properties be the greater primary stability, in addition to incorporating more eff ective bacterial seal and decreased reduction in preload. The conical implants simulates the natural shape of the root of the tooth, for this reason are perfectly suited for postextraction surgeries.
excellence
8 9
Its two helical cutting sides and its conical apical design give the clinician the possibility to change the direction of the implant during the placement, boosting notably the success rate of the surgeries.
Advantages of the MPI Excellence®The MPI Excellence® implant system is characterized by its conical body. The implant achieves a high primary stability by condensing the bone through the osteotome eff ect. Due to the design of its threads it is ideal for post-extraction surgeries.
The double entrance of the threads enables an easy and continuous insertion of the implant.
The active and self-tapping threads increasing in the apical direction condense the bone gradually, obtaining high initial stability quotients in all types of bone densities.
The micro thread in the coronal part reduces the marginal implant bone loss and benefi ts the implant with an improved fatigue resistance.
Double superfi cial treatment. Its macro- and microstructure act in favour of the adhesion of the osteoblasts, responsible for the formation of the bone. The healing periods are reduced and the early bone-to-implant contact is boosted.
Super� cial treatment Integratec®
Leeway to manoeuvre and react
Conical Seal Design
The commercially pure Titanium Grade IV cold drawn material used for the production of the implants, reinforces the implant structure hardness by 20%. This characteristic permits higher torque values during the insertion of the implant.
Material of German or Swiss origin.
High performance titanium
INTERNAL CONNECTION
CONICAL SEAL
Thread design
Coronal Design
Apical design
In order to be able to react and stop bacterial colonisations in early stages, the coronal neck has no surface treatment.
Decontamination processes are more eff ective and faster and a minimization of the bone loss is granted..
The double internal hexagon permits a fast and adjusted insertion of the prosthetic components, achieving a completely hermetic mechanical closing and tightness.
The mono-block behaviour prevents bacterial fi ltrations and strength-ens the design avoiding the physical fatigue when they work as a set.
10 1110 11
MPI Excellence®System
Connection ConicalSeal
Internal
This makes it possible a mechanical seal totally hermetic and an implant sealing with the prostheses that allows a single block performance, optimizes the bacterial seal and the health of the peri-implant tissues.
12 13
Drilling Sequence IECM
Healing Screw
MPI Excellence® CM
- To use with Screwdriver hexagonal manual Ø 1,2 mm (SDHM 121 / SDHM 122). - Maximum torque recommended: 10 Ncm.
Ø 3,5 / Ø 3,75 / Ø 4,3 Ø 5
0mm - CM594 0mm - CM595
OPTIONALTYPE IV TYPE III TYPE II TYPE I *
Internal Connection Conical Seal
Product features
- The micro thread in the coronal part benefi ts the implant with an optimal
distribution of the functional loads and reduces the marginal implant bone
loss
- Tapered body and wide thread step permits an easy insertion as well as
an improvement of the primary stability through constant bone condensing
during the insertion.
- The width of the self-tapping implant threads increase progressively from
the apical to the coronal part.
- Sharp helical cutting sides enable the implant to penetrate into reduced
implant beds. - Direct surgery through the conical handpiece connectors (H/P
CON CS and H/P CON CL) – no implant mounts required.
- Reinforced implant structure by the use of Titanium Grade 4 cold drawn
bars.
- Cover screw included in the implant package.
- Indicated for all types of bone densities, especially type IV and post-
extraction surgeries.
- Insertion revolution: 30 rpm.
- Maximum torque recommended: 80 Ncm.
D - Diámetro ( mm )
IECM Ø 3,5 Ø 3,75 Ø 4,3 Ø 5
8,5 IECM38 IECM378 IECM48 -
10 IECM310 IECM3710 IECM410 IECM510
11,5 IECM311 IECM3711 IECM411 IECM511
13 IECM313 IECM3713 IECM413 IECM513
15 IECM315 IECM3715 IECM415 IECM515
M 1,6 M 2,0
H -
Long
itud
( mm
)
1,6 mm
H
45 º22 º
1,2 mm
D
Ø 3,5 Ø 3,75 Ø 4,3 Ø 5
Lance Drill
Drill Ø 2,0
Conical Drill Ø 3,5
Conical Drill Ø 3,75
CónicaConical Drill
Conical Drill Ø 5
Pilot Drill Ø 3,5
Pilot Drill Ø 3,75
Pilot Drill Ø 4,3
Pilot Drill Ø 5
Tap
*2 marks
*1 marks
*2 marks
*1 marks
*2 marks
*1 marks
*2 marks
*1 marks
14 1515
Prosthetic Components // Post-Surgical Phase MPI Excellence® CM
Healing Abutment Straight- Made of Titanium Grade V.- Maximum torque recommended 10 Ncm. - To use with Screwdriver 1,2 mm (SDHM121 / SDHM122).
Ø 3,5 / Ø 4 Ø 3,5 / 3,75 / 4,3 Ø 5Ø 4 - 42 mm EXC701 -
3 mm EXC702 EXC706
4 mm EXC703 -
5 mm EXC704 EXC707
7 mm EXC705 EXC708
Healing Abutment Aesthetic- Made of Titanium Grade V.- Maximum torque recommended 10 Ncm.- To use with Screwdriver 1,2 mm (SDHM121 / SDHM122).
Ø 3,5 / 3,75 / 4,3 Ø 5
Ø 4 - 5 Ø 5 - 6
3 mm EXC709 EXC711
5 mm EXC710 EXC712
Temporary Abutment- Made of Peek.- Maximum torque recommended 10 Ncm.- It is recommended hexagonal abutment for single restorations and cylindrical abutment for multiple restorations.- Use in temporary restorations.- Defi nitive screw is not included*
HEXAGONAL HEXAGONAL CYLINDRICAL *SCREW
Ø 3,5 / 3,75 / 4,3 CM523 CM525 CM535
Ø 5 CM524 CM526 CM536
16 17
Prosthetic Components // Prosthetic Phase
Conical Abutment Straight- Carved Abutment made of Titanium Grade V. - Maximum torque recommended 30 Ncm. - For direct implant restorations. - For cemented prosthesis. - It is recommended that the height of the gingiva be greater than the height of the conical abutment step. - It is packaged with the abutment screw. (EXC735 / EXC736).
Conical Abutment Angled- Made of Titanium Grade V. - Maximum torque recommended 30 Ncm. - For direct implant restorations. - For cemented prosthesis. - It is recommended that the height of the gingiva be greater than the height of the conical abutment step. - It is packaged with the abutment screw. (EXC735 / EXC736).
MPI Excellence® CM
Impression Coping Open Tray- Made of stainless steel.- Maximum torque recommended 10 Ncm. - To use with Screwdriver 1,2 mm (SDHM121 / SDHM122).
Impression Coping Closed Tray- Made of stainless steel. - Maximum torque recommended 10 Ncm. - Only use with Closed Tray.
CYLINDRICAL STRAIGHT CYLINDRICAL AESTHETIC
Ø 3,5 / 3,75 / 4,3 CM545 Ø 3,5 / 3,75 / 4,3 - 5 CM547
Ø 5 CM546 Ø 5 - 6 CM548
Implant Replica
- Made of stainless steel.
Ø 3,5 / 3,75 / 4,3 Ø 5
EXC749 EXC750
Ø 3,5 / 3,75 / 4,3 Ø 5
1 mm CM551 CM555
2 mm CM552 CM556
3 mm CM553 CM557
4 mm CM554 CM558
HEXAGONAL STRAIGHT HEXAGONAL AESTHETIC
Ø 3,5 / 3,75 / 4,3 CM541 Ø 3,5 / 3,75 / 4,3 - 5 CM543
Ø 5 CM542 Ø 5 - 6 CM544
ANGULATION 15° ANGULATION 25°
Ø 3,5 / 3,75 / 4,3 CM559 CM560
Ø 5 CM561 CM562
18 19
Prosthetic Components // Prosthetic Phase Prosthetic Components // Advanced Prosthetic Phase
CrCo Base Castable Abutment- Maximum torque recommended 30 Ncm. - For direct implant restorations. - For cemented prosthesis. - It is recommended hexagonal abutment for single restorations. - All non-rotating castables are in black color for easily identify. - It is packaged with the abutment screw (EXC735 / EXC836).
Transepithelial Uniblock Abutment- Made of Titanium Grade V. - Maximum torque recommended 30 Ncm. - For multiple restorations.
Transepithelial System
18
HEXAGONAL CILÍNDRICO
Ø 3,5 / 3,75 / 4,3 CM575 CM577
Ø 5 CM576 CM578
MPI Pack
HEXAGONAL CYLINDRICAL
Ø 3,5 / 3,75 / 4,3 MPI PACK CMS HEX. MPI PACK CMS CIL.
Ø 5 MPI PACK CML HEX. MPI PACK CML CIL.
- Package is composed of: Impression Coping, Replica, CrCo Base Castable and Abutment Screw.
Ø 3,5 / Ø 3,75 / Ø 4,3 Ø 5
1,5 mm EXC765 EXC769
2,5 mm EXC766 EXC770
3,5 mm EXC767 EXC771
4,5 mm EXC768 EXC772
Transepithelial Angled Abutment- Made of Titanium Grade V.- Maximum torque recommended 30 N.cm.- Rotating, for multiple restorations- Allow non-parallelism correction between implants.- Indicated for implants Ø4,3 mm.- Defi nitive screw included (TR001).
Transepithelial Angled Abutment- Made of Titanium Grade V.- Maximum torque recommended - Rotating, for multiple restorations
17º 30º
2,5 mm CM569 -
3,5 mm CM570 CM571
4,5 mm - CM572
20 21
Prosthetic Components // Advanced Prosthetic Phase MPI Excellence® CM
TR002
Impression Coping Open Tray- Made of stainless steel. - Maximum torque recommended 10 N.cm.- To use with Screwdriver 1,2 mm (SDHM121 / SDHM122).
TR003
Impression Coping Closed Tray
- Made of stainless steel. - Maximum torque recommended 10 Ncm. - Indicated for multiple restorations.
TR004
Replica- Made of stainless steel.
2 mm TR008
3 mm TR009
Short screw M 1,4
TR007
Healing Cap
TR006
Provisional
- Made of Peek. - Maximum torque recommended 10 Ncm. - Defi nitive short screw M 1,4 is not included (TR008 / TR009).
- Made of Titanium Grade V. - Maximum torque recommended 10 N·cm. - For transepithelial uniblock abutment use TR009. - For transepithelial angled abutment use TR008.
TR011
Straight Abutment- Made of Titanium Grade V. - For multiple restorations. - Defi nitive short screw M 1,4 is not included (TR008 / TR009).
Transepithelial System
TR005
Castable
- To use with screw-retained prostheses. - Indicated for multiple restorations. - Defi nitive short screw M 1,4 not included (TR008 / TR009).
REF. TR010
Hand Piece Connector
22 23
Prosthetic Components // Advanced Prosthetic Phase
Standard Range Male Processing Package
Locator® System
LO8505 LO8530
Impression Coping Analog
MPI Excellence® CM
Locator® Bar Attachment System
Bar Abutment Thread (Pack 2 units) LO8589
Castable Threaded Insert (Pack 10 units) LO8014
Bar Male Processing Package (Pack 2 units) LO8028
Cast-to Abutment (pack 2 units) LO8586
Bar Male Processing Package (pack 2 units) LO8028
LO8393
Retention Replacement Male
Locator® Core Tool
Drill & tap
Cast to
White (2,27 Kgf) LO8524
Pink (1,36 Kgf) LO8527
Blue (0,68 Kgf) LO8529
Green (1,36 - 1,81 Kgf) LO8547
Red (0 - 0,68 Kgf) LO8548
LO8519
Allows divergent abutments up to 20º.
LO8540
Allows divergent abutments up to 40º.
Extended Range Male Processing Package
Locator® Abutment- Threaded abutment directly to the implant. - Indicated for overdentures. - It tolerates an implant divergence between 20º y 40º. - Use with the Locator® tool (LO8393).
Ø 3,5 / 3,75 / 4,3 Ø 5
1 mm LO8115 LO8686
2 mm LO8116 LO8687
3 mm LO8117 LO8688
4 mm LO8118 LO8689
5 mm LO8119 LO8690
Locator® U.S. Patent Nos. 6,030,219 and 6,299,447.
24 25
Prosthetic Components // Advanced Prosthetic Phase MPI Excellence® CM
Equator® System
Equator® Abutment- Threaded abutment directly to the implant. - Indicated for overdentures. - It tolerates an implant divergence up to 50º. - To used with Equator® tools (EQ1001 / EQ1009). - Standard range male processing package included in the Equator® abutment package.
Internal Conection Conical Seal
Ø 3,5 / 3,75 / 4,3
1 mm EQCM341
2 mm EQCM342
3 mm EQCM343
4 mm EQCM344
5 mm EQCM345
6 mm EQCM346
7 mm EQCM347
Equator® Tools
EQ1001 EQ1009
Analog
EQ1010
Impression Coping
EQ1002
Retention Replacement Male
Black EQ1003
Purple EQ1005
Pink EQ1006
Yellow EQ1007
White EQ1008
26 27
Dynamic Screw
- Maximum torque recommended 20 N·cm. - To used with angled screwdriver KD9142.
Ø 3,5 / 3,75 / 4,3 CM579
Ø 5 CM580
CAD-CAM System Angled System
Prosthetic Components // Digital Solutions MPI Excellence® CM
Scanbody
- Made of Titanium Grade V. - Surface treatment which avoids reflection. - Served with the abutment screw (CM535 / CM536).
HEXAGONAL TRANSEPITHELIAL
Ø 3,5 / 3,75 / 4,3 CM610 Ø 5 CM611 Ø 4,3 CM609
Digital Analog
- Made of stainless steel.
HEXAGONAL TRANSEPITHELIAL
Ø 3,5 / 3,75 / 4,3 CM612 Ø 5 CM613 Ø 4,3 CM614
Ti Base
- Made of Titanium Grade V. - Titanium Nitride (TiN) surface treatment. - Served with the abutment screw (CM535 / CM536). - Allows angulation with dinamic screw up to 30º.
CYLINDRICAL HEXAGONAL TRANSEPITHELIAL
Ø 3,5 / 3,75 / 4,3 CM600 Ø 3,5 / 3,75 / 4,3 CM602 Ø 4,3 CM604
Ø 5 CM601 Ø 5 CM603 - -
Angled Castable - Maximum torque recommended 20 N·cm. - To use with screw-retained prostheses. - Served with dynamic screw (CM579 / CM580).
HEXAGONAL CYLINDRICAL
17º 30º 17º 30º
Ø 3,5 / 3,75 / 4,3 CM585 CM587 CM581 CM583
Ø 5 CM586 CM588 CM582 CM584
Dow
nload our library in ww
w.m
pimplants.com
28 29
Surgical Material
MPI Privilege® HE
Reduced screw CM TR001
Angled screw short M 1,4 (2 mm) TR008
Straight screw short M 1,4 (3 mm) TR009
MPI Privilege® MPI Excellence®Transepithelial System
Abutment screw hex. 1,2 mm Ø 3,5 / Ø 4 - CM535
Ø 5 - CM536
Laboratory screw 1,2 mmØ 3,5 / Ø 4 - CM537
Ø 5 - CM538
Gold screw hex. 1,2 mmØ 3,5 / Ø 4 - CM539
Ø 5 - CM540
Dynamic screwØ 3,5 / Ø 4 - CM579
Ø 5 - CM580
Conical Seal
Screws to abutments
30 31
Reference Description
DCC001 Dental Case Combinated
MPI Excellence® y MPI Privilege®Dental Case Combinated
Contents of Dental Case
Initial Lance DrillHand Piece Connector conical
Ø 3,5 / 4 mmScrewdriver Manual 1,0 mm Hex.
Initial Drill Ø 2 x 15 mm Hand Piece Connector Conical Ø 5 mmRatchet Extensor Conicall Small / Long
Ø 3,5 / 4 mm
Tap Conical Ø 3,5 mm Pilot Drill Conical Ø 3,5 mmRatchet Extensor Conical Large Long
Ø 5 mm
Tap Conical Ø 3,75 mm Pilot Drill Conical Ø 3,75 mmScrewdriver Hexagonal Manual
1,2 mm Hex.
Tap Conical Ø 4,3 mm Pilot Drill Conical Ø 4,3 mm Wrench Standard
Tap Conical Ø 5 mm Pilot Drill Conical Ø 5 mm Dental Case
Reference Description
DCE36 Excellence® Dental Case
MPI Excellence® Dental Case
Contents of Dental Case
Dental case Hand piece connector Tap conical Ø 5 mm
Lance drill Ratchet extensor long Directional indicators conical
Drill extensor Ratchet extensor shotHand piece connector conical Ø 3,5 / 4 mm
Initial drill Ø 2x15 mm Conical drill Ø 3,5 mm Hand piece connector conical Ø 5 mm
Drill Ø 2,75 mm Conical drill Ø 3,75 mm Ratchet extensor Ø 3,5 / 4 mm
Drill Ø 3 mm Conical drill Ø 4,3 mm Ratchet extensor Ø 5 mm
Step drill Ø 3,25 / 3,60 mm Conical drill Ø 5 mm Screwdriver hexagonal manual 1,0 mm
Step drill Ø 4,25 / 4,60 mm Pilot drill conical Ø 3,5 mm Screwdriver hexagonal manual 1,2 mm
Countersink Pilot drill conical Ø 3,75 mm Motor screwdriver 1,2 mm Hex. Short
Pilot drill Pilot drill conical Ø 4,3 mm Motor screwdriver 1,2 mm Hex. Long
Tap Ø 3 mm Pilot drill conical Ø 5 mm Wrench standard
Tap Ø 4 mm Tap conical Ø 3,5 mm Open holding key
Tap Ø 5 mm Tap conical Ø 3,75 mm Implants depth gauge
Straight directional Indicators Tap conical Ø 4,3 mm
31
Dental Case
Surgical Material
32 33
Surgical Material
DRILL IDENTIFICATION AND PACK
Surgical Drills
11,5
mm
10 m
m
8,5
mm
13 m
m15
mm
7 m
m
0 m
m
Conical Drill
INITIAL DRILL
DIAMETER REFERENCE
1,9 mm RD1910
- LD3310 DLC
- LD3310
- LD3317
2,0 mm D215
CONICAL DRILLS
DIAMETER REFERENCE
3,50 mm CD3
3,75 mm CD37
4,30 mm CD4
5,00 mm CD5
PILOT DRILLS / COUNTERSINK
DIAMETER REFERENCE
3,50 mm PDC3
3,75 mm PDC37
4,30 mm PDC4
5,0 mm PDC5
TAPS
3,50 mm TAPC3
3,75 mm TAPC3,7
4,30 mm TAPC4
5,0 mm TAPC5
34 35
DIRECTIONAL INDICATORS
Directional Indicator Conical Ø 3,50 mm DIC3
Directional Indicator Conical Ø 3,75 mm DIC37
Directional Indicator Conical Ø 4,30 mm DIC4
Directional Indicator Conical Ø 5,0 mm DIC5
TRANSPORTADORES
Motor Hand Piece Connector Conical Ø 3,5 / 3,75 / 4,3 Small EXC900
Motor Hand Piece Connector Conical Ø 3,5 / 3,75 / 4,3 Large EXC901
Motor Hand Piece Connector Conical Ø 5 Small EXC902
Motor Hand Piece Connector Conical Ø 5 Large EXC903
EXTENSORES
Drill Extensor DEP010
Ratchet Extensor Conical Ø 3,5 / 3,75 / 4,3 Small EXC910
Ratchet Extensor Conical Ø 3,5 / 3,75 / 4,3 Large EXC911
Ratchet Extensor Conical Ø 5 Small EXC912
Ratchet Extensor Conical Ø 5 Large EXC913
SCREWDRIVERS
Screwdriver Hexagonal Manual 1,0 short SDHM101
Screwdriver Hexagonal Manual 1,0 long SDHM102
Screwdriver Hexagonal Manual 1,2 short SDHM121
Screwdriver Hexagonal Manual 1,2 long SDHM122
Laboratory 1,2 SDLB
Screwdriver Flat Manual SDFM010
Motor Screwdriver Hexagonal short MSD010
Motor Screwdriver Hexagonal long MSD020
Screwdriver for Wrench 1,2 short SDWR121
Screwdriver for Wrench 1,2 long SDWR122
20 mmAngle Screwdriver 25 mm
30 mm
KD9142SKD9142MKD9142L
SURGICAL TOOLS
Implants Depth Gauge IDG 010
Open Holding Key OHK 010
Wrench Standard WST 010
Torque Wrench WST 020
Ø 3,5Bone Cutting System Ø 4
Ø 5
BCS 3BCS 4BCS 5
Material quirúrgico
36 37
GeneralInformation
38 39
Packaging Opening Instrutions Tag Symbology
• Purple packaging: Implant MPI Excellence® CM
Designed for easy identifi cation of each implant. According to the color of the outer box, we can fi nd:
.
7
Remove the blister from the box. Check that the blister and the label are intact.
Remove the Tyvek® from the blister. Reserve patient labels for your history.
MPI Privilege®: Hook the H/P CONNECTOR to the implant and place according to surgical criteria. With the motor or manual
screwdriver, remove the closing screw
Remove the white cap from the tube.
Deposit the implant on a sterile surface.
Open the cap, inside we will fi nd the closing screw.
When removing the cardboard fl ap you will fi nd the instructions for use and the blister.
Implant description and measurements are indicated:• IECM: MPI Excellence® Conical Seal
Bar code with linked batch number.
Patiens labels indicating reference, lot and description
5
2
1
3
4
6
Simbología
Manufacturer
Date of manufacture
Batch code
Catalogue number
Protect from heat andradioactive sources
Keep dry
Consult instructions for use
Caution
Do not use if package is damaged
CE marking with the identified organism number
Catalogue number
Protect from heat andradioactive sources
Keep dry
Consult instructions for use
CM 3,5 CM 3,75 CM 4,3 CM 5
Ø Body/ platform (mm)
40 41
Recommended implants placement
Implants types: Narrow platform. - MPI Excellence® CM Ø 3,5
- MPI Excellence® CM Ø 3,75
Instructions for use suitable bone qualities: For fi xed, single- and multiple-unit restorations.
Recommendation for located replacement parts: Lateral incisors in the upper jaw, lateral incisors and central incisors in the
jaw. For edentulous patients with 4 implants supported overdenture in the
anterior and mid areas.
Implants types: Wide platform.- MPI Excellence® CM Ø 5
Instructions for use suitable bone qualities: For fi xed, single- and multiple-unit restorations.
Recommendation for located replacement parts: Molars in both jaws.
Implants types: Regular platform. - MPI Excellence® CM Ø 3,75
- MPI Excellence® CM Ø 4,3
Instructions for use suitable bone qualities: For fi xed, single- and multiple-unit restorations.
Recommendation for located replacement parts: Central incisors, canines and premolars in the upper jaw and canines and
premolars in the jaw.
41
Recommendation for located replacement parts: Central incisors, canines and premolars in the upper jaw and canines and
42
Quality and General Conditions of Sale
Quality
To ensure the highest quality standards, our metrology lab is equipped with state-of-the-art measuring
equipments. By the stringent quality control procedures, we have reached a success rate over 99%. Its “zero
defects” policy is the basis of the quality of its products and satisfaction of their customers.
Thanks to demanding quality controls, we have achieved a success rate of over 99%. The “Zero defects” policy
is our fundamental basis for the quality of our products and the satisfaction of our customers.
Order Delivery
Tlfn: +34 91 684 60 63
E-mail: [email protected]
Order Verification
Once the order has been delivered, MPI advises their clients to verify the delivered products and quantities
so as to confirm that during the transport no damage has been caused. For any questions that should appear,
please contact our sales department.
Returns
Items may be returned up to 15 days after the delivery note date. No changes will be accepted once the
material has been opened or used, or if the packaging is not in perfect conditions.
Payment Terms
Direct debit.
Cash on delivery.
Warranty
We guarantee the replacement of our products as long as they are combined with original MPI components. No
returns or refunds will be allowed two months after the cause of failed material.
Top Related