Download - DATASHEET ALTERNATOR - East Coast Generators

Transcript

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

-GENERAL CHARACTERISTICS-

Capacity for maintaining short circuit at 3 ln for 10 s NoWinding type Standard

Efficiency & Power

Class H Class F Class B125°C/ 40°C continuous

130°C/ 25°C standby

150°C/ 40°Cstandby

163°C/ 27°Cstandby

105°C/ 40°C continuous

80°C/ 40°C continuous

Nominal Rating(Kva) 150 150 158 165 137 120Nominal Rating(KW) 120 120 126.4 132 109.6 96Efficiency 100% 92.9 92.9 92.7 92.6 93.1 93.3

-ELECTRICAL CHARACTERISTICS-

Voltage regulation at established rating (+/- %) 0.5Insulation class HT° class (H/125°), continuous 40°C H / 125°KT° class (H/163°C), standby 27°C H / 163°KWave form : NEMA=TIF <50Unbalanced load acceptance ratio (%) 100Number of wires 12Total Harmonic Distortion in no-load DHT (%) <2Wave form : CEI=FHT <2Total Harmonic Distortion, on linear load DHT (%) <5Technology Without collar or brushL-L Harmonic Maximum - Single (%) 18Deviation Factor (%) 3Shaft CurrentMain Stator Capacitance to ground (mdf)

Reactances

Direct axis synchro reactance unsaturated (Xd) (%) 305Direct axis transcient reactance saturated (X'd) (%) 14.6Direct axis subtranscient reactance saturated (X''d) (%) 8.8Quadra axis synchro reactance unsaturated (Xq) (%) 155Quadra axis subtranscient reactance saturated (X"q) (%) 17.4Zero sequence reactance unsaturated (Xo) (%) 0.6Negative sequence reactance saturated (X2) (%) 13.11

Short circuit ratio

Short circuit ratio (Kcc) 0.487Subtranscient time constant (T"d) (ms) 10

Voltage Type (V) 400/230 Altitude (m) 0-1000Number of Phase Three phase AVR Regulation YesNumber of pole 4 Indication of protection IP23

Frequency (Hz) 50 Hz Nominal voltage (V) 400

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Short circuit transcient time constant (T'd) (ms) 100Open circuit time constant (T'do) (ms) 2077Subtranscient time constant (T"q) (ms) 10Leakage stator reactance (Xa)(%) 0.73Stator Resistance (Ra)(%) 0.022Armature time constant (Ta) (ms) 15

No load excitation current (io) (A) 0.67Full load excitation current (ic) (A) 2.45Full load excitation voltage (uc) (V) 29.9Heat rejection (W) 9127.9No load losses (W) 2861.03Stator resistance (for 20°C ambient ) (Ω) 0.0236Rotor resistance (for 20°C ambient ) (Ω) 3.43285Exciter resistance - stator/inductor (for 20° ambient ) (Ω) 12.941Exciter resistance - rotor/armature (for 20° ambient ) (Ω) 0.459

Recovery time (Delta U = 20% transcient) (ms) 500Engine start (Delta U = 20% perm. or 30% trans.) (kVA) 324.07Transcient dip (4/4 load) - PF : 0,8 AR (%) 13

Additional electrical characteristics-

Winding X1, X2 auxiliary resistance (for 20° ambient ) (Ω) 0Auxiliary winding X1, X2 excitation voltage at no load (V) 0Auxiliary winding X1, X2 excitation voltage on load (V)Winding Z1, Z2 auxiliary resistance (for 20° ambient ) (Ω) 0Auxiliary winding Z1, Z2 excitation voltage at no load (V) 0Auxiliary winding Z1, Z2 excitation voltage on load (V)

-MECHANICAL CHARACTERISTICS-

Number of bearing 1Overspeed (rpm) 2250Coupling Direct

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

-TECHNICAL CURVES-

Motor starting curve locked rotor (0,6PF)

Motor starting curve locked rotor (0,3PF)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Efficiencies curve (by excitation system)

Loading curve (by excitation system)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Short circuit curve at no load and rated speed

Influence due to connectionCurves shown are for star (Y) connectionFor other connections, use the following multiplication factors :

- Series delta : current value x 1.732- Parallel star : current value x 2

Influence due to short-circuitCurves are based on a three-phase short-circuit. For the other types of short-circuit, use the following multiplication factors :(*) Capacity for maintaining short circuit at 3 ln for 10 s = YES

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Rejection curve (by excitation system)

Capability curve (PQ diagram)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

DIMENSIONS-

Overall dimension drawing (Single bearing)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Overall dimension drawing (Two bearings)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

-TORSIONAL ANALYSIS DATA-

Rotation part drawing for torsional vibration calculation (Single bearing)

DATASHEET ALTERNATORAlternator ref. KH01340TAlternator type KH01340TN4N

3.351411E+10-AThe generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever

Rotation part drawing for torsional vibration calculation (Two bearings)