Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 101 }
SPPL
CHAPTER – 4
ENVIRONMENTAL
IMPACT ASSESSMENT
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 102 }
SPPL
Chapter - IV
Environmental Impact Assessment
4.1 Introduction
Environmental Impact Assessment (EIA) is a process or an endeavour
to identify, predict, assess and convey the probable environmental
impacts due to the project on various components of environment of
the surrounding area. Predicted impacts are then superimposed on
existing base-line status (pre-project) to make an effort to arrive at the
resultant environmental scenario after the project becomes operational
(post-project). Resultant post-project scenario is further evaluated
against the statutory environmental regulations applicable to the area
to find out if the post project scenario will be in conformity with the
requirements or not. Evaluation and prediction of environmental
impacts of the project also helps in developing a proper Environment
Management Plan (EMP) incorporating measures to mitigate negative
impacts and enhance positive impacts during project implementation
and operation phase.
Process of impact assessment basically includes :
• Identification of different project activities and their likely impacts.
• Categorisation of likely impacts based on nature (positive or negative,
direct or indirect), duration (short term or long term), magnitude
(negligible, moderate or severe), reversible or irreversible etc.
• Assessment of qualitative and quantitative aspect of the likely impacts.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 103 }
SPPL
This chapter presents the identification, prediction and evaluation of
various impacts with mitigation measures of the proposed bulk-drug
manufacturing activity of SPPL at Plot No. 632, 633, Nadiad –
Mahemdabad Highway, Village – Varsola, Ta – Mahemdabad, Dist –
Kheda, Gujarat. Impacts are predicted considering that the impact of
existing sources of pollution has already been taken into account in the
baseline environmental status.
Prediction and evaluation of impact on components of environment i.e.
water, land, noise, flora-fauna etc. has been done using scientific
knowledge and judgment.
4.2 Impact Identification For the purpose of impact identification, the entire project has been
divided into two phases :
1. Pre - operational Phase ( construction and erection/commissioning )
2. Operational Phase
4.2.1 Construction and Commissioning Phase
As SPPL has complete infrastructure suitable for manufacturing of
proposed products, no major construction activity will be required to be
carried-out. Only minor civil work like foundation of new vessels etc.
will be carried-out. During commissioning, mechanical and electrical
erection of equipments / machineries will be carried-out. The broad
activities during this period will be as follows :
1) Foundation work only for new machinery.
2) Erection of only new mechanical equipments.
3) Synchronisation of various equipments / processes and final
commissioning of plant.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 104 }
SPPL
Construction cum commissioning phase of the project will be for a
shorter duration as compared to operational phase.
Construction cum commissioning phase will mainly involve noise
pollution (erection of mechanical machineries etc.) and demand for
water (for domestic requirement of construction and commissioning
work force).
Though Aesthetics and Socio-economic factors are also identified,
the impacts related to the same will be marginal only.
Mostly, local man power will be used during this phase. Similarly, there
will be no displacement and rehabilitation of people due to this project.
4.2.2 Operational Phase Because of its’ potential to create long-term impacts, this phase is
very important from the environmental impact point of view. The basic
impacts like gaseous emissions, water consumption and solid waste
will have potential to adversely affect air, water and land / soil in the
vicinity of the project site.
This phase will broadly include following direct and indirect activities /
actions :
• Entire chain of activities related to production cycle.
• Storage and transportation of raw materials and finished
products.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 105 }
SPPL
• Gaseous emissions
• Effluent Generation, treatment and disposal
• Noise Generation
• Solid waste generation
• General equipment failure
• Industrial development of secondary units in the area
• Greenbelt Development 4.3 Prediction And Assessment Of Impacts
Prediction and assessment of impacts during construction and commissioning phase and operational phase of the project is given below :
4.3.1 Construction and Commissioning Phase
4.3.1.1 Air Environment
Impact on air environment due to construction and commissioning
activities will be negligible as construction activity itself will be limited
to few foundations of new equipments. Thus, impact on SPM and
gaseous emission levels will be negligible during this period. Power for
construction cum commissioning work will be obtained through grid
power.
However, all efforts will be made to ensure that impact on air
environment is minimum. This will include :
Minor civil construction work will be carried out during day time.
Separate civil construction material storage yard will be created
within the site and it will be enclosed.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 106 }
SPPL
4.3.1.2 Water Environment
Total water requirement for construction cum commissioning activities
is estimated to be approx. 2 cu. mt. per day. It will be met through
existing bore well.
Company has no plan to create temporary housing arrangement for
construction labourers at site as only minor civil work will be there. The
peak labour force during construction cum commissioning phase is
expected to be 10 persons. Only drinking water and other
miscellaneous requirement during day time for this work force will be
there which is estimated to be approx. 2 cu. mt. per day. This
requirement too will be met through existing bore-well.
Thus, construction and commissioning activities are not likely to have
any adverse impact on quality and availability of water in the
surrounding region.
4.3.1.3 Solid Waste
Remains of construction material like rubble, brick bats, debris, steel
scrap, wooden scrap, sand, gravel etc. are the only likely solid wastes
to be generated during minor construction activity of the project.
However, such solid wastes are inert in nature and will be collected and
utilised in filling of low lying areas within the premises of project site.
Wooden scrap, steel scrap will be given to scrap dealers.
Therefore, construction activities are likely to have no adverse impact
due to generation of solid wastes.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 107 }
SPPL
4.3.1.4 Noise Environment
As a result of various activities like civil construction, erection,
movement of vehicles and installation of machinery etc., slight increase
in noise level is anticipated for a short period. However, all construction
and commissioning activities will take place during day time only and
consequently noise level is expected to go up during day time only.
4.3.1.5 Land Environment
As no major construction activity will take place, no significant change
to the topsoil of the project area due to excavation, stacking of
construction material etc. is anticipated. Also, no impact on land
outside the premises will be there due to construction activity.
4.3.1.6 Ecology
The components that are identified to describe ecology are animals,
birds, fish, field crops, threatened species, natural vegetation etc. The
area where SPPL unit is located does not have any Forest, National
Park, Sanctuaries etc. and hence there is no question of impact on the
same.
Since the construction and commissioning activity will be very limited
and restricted to the existing site only, no change in local ecosystem is
anticipated because of this project of bulk – drug manufacturing.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 108 }
SPPL
4.3.1.7 Socio – Economic Pattern
The construction and commissioning phase of the proposed bulk – drug
manufacturing project is likely to have certain positive and negative impacts
on socio-economic environment.
Setting up of project at the said site does not require displacement of
any population. Local people involved during construction and
commissioning work will have benefit of temporary employment.
However, there will be pressure of additional traffic on State Highway
No. 3 due to movement of vehicles for construction material and
equipments. But it will be very minor impact for a very short duration.
4.3.1.8 Health and Safety
No health and safety problem of surrounding population is anticipated due to
construction and commissioning activities of the proposed project.
No health problems of labour force are anticipated as there will be no labour
force staying at site.
SAFETY
All safety measures will be incorporated during the construction and
commissioning phase to ensure full safety of work-force and workers
will be made aware of the safety requirements and asked to strictly
follow the safety norms.
4.3.1.9 Aesthetics
Construction activities will contribute to some deterioration of site
aesthetics. However, it will be restricted to site only. Aesthetic value of
the site will be restored after civil work is over.
Various impacts of construction phase alongwith their characteristics
are summarized in TABLE NO. – 4.1.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 109 }
SPPL
TABLE NO. 4.1
IMPACT MATRIX FOR CONSTRUCTION PHASE Activity Construction Construction Movement of Gaseous Solid Green Materials Activities Transportation Emissions Waste Belt Storage & Vehicles generation Development Parameter Handling Air Negligible Negligible -ve, ST -ve ST No Impact +ve, LT Water No Impact Negligible No Impact No Impact No Impact +ve, LT Noise -ve, ST -ve, ST -ve, ST No Impact No Impact +ve, LT Odour No Impact No Impact No Impact No Impact No Impact +ve, LT Flora No Impact No Impact No Impact No Impact No Impact +ve, LT Fauna No Impact No Impact No Impact No Impact No Impact +ve, LT Soil -ve, ST -ve, ST No Impact No Impact Negligible +ve, LT Forest No Impact No Impact No Impact No Impact No Impact No ImpactReligious / Historical Places
No Impact No Impact No Impact No Impact No Impact No Impact
Population +ve, ST +ve, ST -ve, ST Negligible No Impact +ve, LT Socio-economic +ve, ST +ve, ST No Impact No Impact No Impact No ImpactCultural No Impact No Impact No Impact No Impact No Impact No ImpactHealth and Safety Negligible -ve, ST -ve, ST Negligible No Impact +ve, LT Aesthetics -ve, ST -ve, ST No Impact No Impact No Impact +ve, LT
+ ve – Positive (beneficial) ST – Short Term - ve – Negative (adverse) LT – Long Term Negligible - Negligible Impact
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 110 }
SPPL
4.3.2 Operational Phase 4.3.2.1 Air Environment
Base line data reveals that ambient air quality in the study area for the
parameters PM2.5, PM10, SO2, NO2 & HCl is well within the permissible
limits as prescribed by the National Ambient Air Quality Standards
(NAAQ) for Industrial Area, Residential, Rural & Other area.
Emission of PM, SO2 & NO2 from stacks attached to non-IBR baby
boilers and Incinerator and HCl emission from scrubber attached to
process vent will form the only source of air pollution.
As the unit is an existing unit manufacturing 3, 2, Gunidino Thiozol 4,
Methyl Thiopropionitrile base, it has two nos. of non-IBR baby steam
boilers, one no. of liquid incinerator and one no. of process scrubber
already working in the premises. For manufacture of proposed bulk-
drag products, no additional stack will be provided. Same steam
boilers, liquid incinerator and process scrubber will be used for bulk-
drug manufacturing also and also for same duration of time per day.
Unit will discontinue manufacturing of existing product and in its’ place
the proposed bulk-drugs are to be manufactured.
Operational parameters of all the stacks and pollutants to be emitted
alongwith their concentration will also remain the same as in case of
existing products.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 111 }
SPPL
Thus, no. of pollutants, their emission rate and total emission for
proposed products will be the same as no. of pollutants, their emission
rate and total emission taking place right now for existing products. And
since the existing air emission from the plant is already reflected in the
background air quality of the study area, no separate calculation of
GLC of various pollutants has been carried out for this project.
4.3.2.2 Water Environment QUANTITY OF WATER CONSUMPTION
The quantity of water required for the domestic use for the project is
about 2.0 m3 / day.
The quantity of fresh water required for the industrial use of the
project will be about 9.5 m3 / day.
The quantity of fresh water required for the gardening purpose of the
project is about 10 m3 / day.
Thus, maximum requirement of raw water for the project will be about
21.5 m3 / day in totality.
Thus, there will be impact on the surrounding water environment due to
the water used for various purposes. It may be noted that existing
water requirement of the unit is around 17.5 m3/day and hence, net
increase in water requirement for proposed new products will be only
4.0 m3/day. However, it will be effectively mitigated by a water
recharging scheme which has been outlined in detail in ANNEXURE –
12. Thus, there will be no negative impact on the ground water
availability of the area due to manufacture of new products.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 112 }
SPPL
QUALITY OF WATER CONSUMED
Baseline data indicates that in the study area, quality of water is
satisfactory to serve for domestic purposes as per Standards
prescribed by the IS : 10500 for drinking water.
QUANTITY OF WASTE WATER GENERATION AND DISPOSAL
Quantity of domestic effluent generated after the operation of the
project will be about 1.7 m3 / day.
Quantity of industrial effluent generated after the operation of the
project will be about 3.5 m3 / day.
QUALITY OF WASTE WATER AND DISPOSAL
All the effluent streams :
Process and washing effluent ( approx. 1.50 KL per day ) Softening plant regeneration water ( approx. 1.00 KL per day ) Cooling tower blow – down effluent ( approx. 0.50 KL per day ) Scrub liquor effluent ( approx. 0.50 KL per day )
will be given in-house treatment in the existing effluent treatment plant (ETP)
of SPPL which consists of primary treatment units (mainly collection cum
neutralization tank). Total effluent quantity will then be incinerated in the in-
house existing incinerator which has a capacity to incinerate 250 Liters of
effluent per hour.
Domestic sewage will be disposed off through septic-tank / soak pit
system.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 113 }
SPPL
Thus, it can be concluded that there will be insignificant adverse impact
on the surrounding environment as it will be a “Zero Discharge out side
premises “ unit.
4.3.2.3 Solid Waste
Details of anticipated solid / hazardous waste generation from the project are
given below.
HAZARDOUS WASTES FROM THE PROJECT
Sr. No.
Description of Solid Waste
Quantity per month (in MT)
Method of collection
1. Spent Carbon / Hyflow from process
0.50 In polythene bags.
2. ETP sludge 1.00 (on dry basis)
-- do --
3. Incineration Ash 1.80 -- do --
4. Discarded drums / containers
50 Nos. --
5. Used oil 0.15 KL In 200 Ltr. Barrel
6. Solvent residue 2.00 - do -
Hazardous wastes will be disposed in following manner :
used oil will be given to CPCB registered recycler / re-processor of oil.
Solvent residue will be given to common incineration facility of BEIL at Bharuch, Gujarat or will be incinerated in-house.
ETP sludge and spent Carbon / Hyflow / Sodium Sulphate etc. will
be disposed off into TSDF of NEPL at Ahmedabad.
Discarded containers after decontamination will be given to registered vendor.
Proper monthly records of generation, storage & disposal of hazardous
waste will be maintained in a register as per the format of Form – 3 of
Hazardous Waste (M, H & T M) Rules – 2008. Annual returns of the
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 114 }
SPPL
disposal of wastes in Form – 4 and Form – 13 (manifests) will be
submitted regularly to the local office.
Thus, it can be concluded that there will be no impact on the
surrounding environment due to generation and disposal of solid waste
during operation phase of the project.
4.3.2.4 Noise Environment
Noise levels in the ambient air are well within the permissible limits
given by the National Ambient Noise Level Standards as confirmed
during base line study. The Leq values of the noise levels within the
plant premises will be kept less than 75 – 70 dB(A) ( during day time
and night time ) which will be within the permissible limit.
Areas where continuous presence of worker is required, workers will be
provided with earplugs.
The major sources of noise from the proposed project will be vehicular
movement, loading – unloading and transfer of material, operation of
various equipments etc.
Development of Green Belt in and around the plant campus helps in
reduction of noise. As already stated, sufficient ear-protecting devices
will be provided to personnel working in high noise generating areas.
Hence, it is unlikely that there will be practically any increase in the
background noise level beyond plant boundary during operation phase
of the project.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 115 }
SPPL
4.3.2.5 Land Environment
Soil is affected by impact of release of air pollutants, effluent disposal
and solid waste disposal. However, as explained in point no. 4.3.2.1
above, there will be no net increase in air pollution due to proposed
bulk – drug manufacturing and gaseous emissions from stacks
attached to non-IBR baby boilers, incinerator and vents attached to
scrubbers will be within the norms. Moreover, vents of proper height
have been provided for quick dispersion and dilution of pollutants into
the air. Thus, there will be no additional effect on the surrounding soil
due to gaseous emission from the project.
There will be no major effect of wastewater on soil as all the
wastewater generated will be incinerated in the in-house incinerator.
The domestic wastewater will be disposed off through septic tank /
soak pit system. Thus, there will be practically very insignificant impact
on land due to disposal of wastewater.
All necessary control steps for each type of Solid Wastes generated will
be taken, and hence there will be no impact of solid wastes generation
on surrounding soil environment.
4.3.2.6 Ecology
Air emissions, liquid effluent disposal and solid waste generation are
likely to have some impact on terrestrial ecosystem.
However, there will be no net increase in air pollution. Treated effluent
will be incinerated and the solid wastes will be collected and disposed
off properly. Hence, negligible impact on ecology is expected.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 116 }
SPPL
SPPL has developed a greenbelt / green cover in about one third of its
total area and sufficient number of plants has been planted in the
premises.
4.3.2.7 Socio – Economic Pattern
The project to manufacture bulk-drugs is likely to have certain positive
impacts on socio-economic environment.
Positive Impacts :
Direct employment generation potential of the project will be for
about 30 persons.
Various modes of indirect employment i.e. transportation, increased
business opportunities to shopkeepers etc. will also be there.
(Local people will be given preference, on merits, wherever found
suitable for all the jobs in the plant, direct as well as indirect).
Over-all improvement in quality of life of people of the study area.
SPPL is committed to the socio – economic up-lift of the area and has
donated computer to the school of the nearby village of Varsola and
has also contributed towards face lift and upkeep of crematorium of Vil.
: Varsola.
Thus, it can be said that the proposed project will have significant
beneficial impact on the socio-economic scenario of the study area.
4.3.2.8 Health and Safety
Various project activities like storage and transportation of raw
materials and finished goods, gaseous emissions, movement of
equipments etc. are likely to have some impact on health and safety of
personnel.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 117 }
SPPL
All the staff and workers will be covered under health insurance
scheme (i.e. ESI), which is statutorily required by Government of India.
Health check up of all employees will be carried out by medical
practitioners, every year, at company’s cost. Whenever required,
special assistance will be provided for medical treatment.
Emergency / Minor Medical Treatment
Company shall retain a medical practitioner in nearby area for providing
quick relief in the event of any accident. The medical practitioner will
also offer medical treatment in the event of minor medical problems
originating during working hours.
Safety
Employees working on the shop floor will be provided with normal
protective wears such as shoes, helmets, hand gloves and respirator
masks wherever required. A list of Personal Protective Equipment has
been enclosed as ANNEXURE - 13. Various safety teams for different
areas of operation will be formulated. A safety officer will co-ordinate
the activities of these teams. The teams have responsibility to promote
safety measures in respective areas. At production locations where
fire hazards exist, systematic fire control equipments will be installed.
Hence, as described briefly above, the proponents of the project have
incorporated all the necessary safety aspects in planning, designing
and operation of the plant as per international practices. These safety
aspects would be adequate for the project. Hence, the impact on this
account has been adequately safeguarded.
Various impacts of operation phase alongwith their characteristics are
summarized in TABLE NO. – 4.2.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT.
{ 118 }
SPPL
TABLE NO. 4.2
IMPACT MATRIX FOR OPERATION PHASE
Activity Raw Production / Product Transportation Gaseous Effluent Solid Employment Green Belt Rain Water Materials Manufacturing Storage of Product Emissions Treatment Waste Development Harvesting & Storage & and and Raw Generation Recharge Parameter Handling Handling Material Air No Impact -ve, LT No Impact -ve, ST -ve, LT -ve, LT No Impact No Impact +ve, LT No Impact Water No Impact -ve, LT No Impact No Impact No Impact -ve, ST No Impact No Impact +ve, LT + ve, LT Noise Negligible -ve, LT Negligible -ve, ST No Impact -ve, LT No Impact -ve, LT +ve, LT No Impact Odor No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact +ve, LT No Impact Flora No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact +ve, LT + ve. LT Fauna No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact +ve, LT + ve, LT Soil No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact +ve, LT + ve, LT Forest No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact Religious / Historical Places
No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact No Impact
Population No Impact +ve, LT No Impact +ve, LT No Impact No Impact No Impact No Impact +ve, LT + ve, LT Cultural No Impact No Impact No Impact No Impact No Impact No Impact No Impact +ve, LT No Impact No Impact Health and Safety Negligible Negligible Negligible Negligible Negligible Negligible No Impact No Impact +ve, LT No Impact
+ ve – Positive (beneficial) ST – Short Term - ve – Negative (adverse) LT – Long Term Negligible - Negligible Impact
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 119 }
SPPL
CHAPTER – 5
ENVIRONMENTAL MANAGEMENT PLAN
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 120 }
SPPL
Chapter – V
Environmental Management Plan 5.1 Introduction
Industrial development is associated with few positive impacts and few
negative impacts on the environment. The negative impacts should not hinder
industrial development but they should be properly mitigated.
An Environmental Management Plan (EMP) has been prepared for the
bulk-drug manufacturing of SPPL to minimize negative impacts and is
formed on the basis of prevailing environmental conditions and likely
impacts of this project on various environmental parameters. This plan
will also facilitate monitoring of environmental parameters.
EMP includes scheme for proper and scientific treatment and disposal
mechanism for air, liquid and solid hazardous pollutants. Apart from this,
green belt development, safety aspect of the workers, noise control, fire
protection etc. are also included in it.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 121 }
SPPL
5.2 Purpose Of Environmental Management Plan
Various purposes of the environmental management plan are:
To treat and dispose off all the pollutants viz. liquid, gaseous and
solid waste so as to meet statutory requirements (relevant
pollution control Acts) with appropriate technology.
To support and implement development work to achieve
environmental standards and to improve the methods of
environmental management.
To promote green-belt development.
To encourage good working conditions for employees.
To reduce fire and accident hazards.
Budgeting and allocation of funds for environment management
system.
To adopt cleaner production technology and waste minimisation
program.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 122 }
SPPL
5.3 Details of Environmental Management Plan 5.3.1 Construction and Commissioning Phase 5.3.1.1 AIR ENVIRONMENT As SPPL has complete infrastructure suitable for bulk-drug
manufacturing, no major construction activity will be required to be
carried-out. Only minor civil work like foundation of new vessels etc.
will be carried-out. During construction activities, minor emission of dust and
gases from movement of vehicles and construction activity is expected.
However, following measures will be taken to reduce / contain such emissions
:
Water will be sprinkled on loose top soil to prevent re-suspension of
dust into ambient air due to movement of vehicles etc.
Separate civil construction material storage yard will be created
within the site and it will be enclosed.
Cement bags will be separately stored under cover in bales. Sand
will be stacked under tarpaulin cover.
Transport vehicles and construction equipments / machineries will be
properly maintained to reduce air emissions.
Idle running of vehicles will be minimized during material loading /
unloading operations.
All construction workers will be provided appropriate PPEs like dust mask,
ear plug, helmet, safety belt etc. and made to wear them during working
hours.
5.3.1.2 WATER ENVIRONMENT
Maximum water requirement for construction purpose including domestic
water requirement of construction workers is estimated to be approximately 2
cu. mt. per day. It will be supplied from the existing bore well. Water quantity
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 123 }
SPPL
being small, no major impact on existing water resources of the study area is
envisaged.
Further, there will be no housing facility at site for construction workers and
hence a major source of impact on water environment will be avoided.
Proper and sufficient sanitary facility already exists at site in the form of
Septic tank / Soak pit system of adequate capacity.
5.3.1.3 SOLID WASTE
Main solid waste generation during construction phase will be construction
debris like rubble, brick bats, debris, steel scrap, wooden scrap, sand, gravel
etc. However, these materials are inert in nature and will not result into
leaching of any substance or constituent.
These materials will be properly sorted and will be used within premises for
filling of low lying areas. Wooden scrap, steel scrap will be given to scrap
dealers.
On completion of civil work, all debris etc. will be completely removed from
site to avoid any incompatibility with future use.
5.3.1.4 NOISE ENVIRONMENT
Following measures are proposed during construction period to mitigate
adverse impacts :
All machineries to be used for construction purpose will be of highest
standard of reputed make and compliance of noise pollution control norms
by these equipments will be emphasized by SPPL.
All construction workers working in high noise areas will be provided
appropriate PPEs like ear muffs and made to wear them during working
hours.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 124 }
SPPL
5.3.1.5 LAND ENVIRONMENT
Following steps are proposed to take care of impact of construction activity on
project land area :
On completion of civil work, all debris etc. will be completely removed from
site to avoid any incompatibility with future use.
Other material like paints, diesel etc. will be properly stored and handled
to prevent any spillage on land.
All the wastes will be stored at a designated site within the premises to
prevent scattered discharge on land.
5.3.1.6 ECOLOGY
Project site is an existing unit with number of shrubs and trees. No tree
cutting exercise will be there and no major impact on ecology is
anticipated.
5.3.1.7 SOCIO - ECONOMIC
As there will be no temporary housing colony for construction workers,
no socio – economic impact due to the same is envisaged.
Over – all socio – economic effect of construction phase will be positive
due to direct and indirect employment opportunity for the local
population.
5.3.2 Operation Phase Operation phase of any industry being longer in duration and because
of its’ potential to create continuous impacts, is much more important
from the environmental impact point of view and a comprehensive and
effective EMP has to be prepared and implemented to safe-guard
environmental concerns during operation phase of any unit.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 125 }
SPPL
5.3.2.1 AIR ENVIRONMENT
Following measures are proposed to mitigate negative impact of
operation phase of the project on the surrounding air environment :
Existing scrubbers will be used to take care of process emissions
from the proposed project.
Height of scrubber vent is as per statutory requirement. The vent
has stack monitoring facility (SMF) consisting of sampling port-hole,
platform and access ladder.
Adequate spares of critical components of scrubber system are kept
to ensure trouble – free operations and continuous compliance to
emission norms.
A comprehensive plan for fugitive emission control is prepared as
outlined in CHAPTER - 2.
Transport vehicles will be properly maintained to reduce air emissions.
Vehicles will be periodically checked for pollutant emissions against
stipulated norms.
Idle running of vehicles will be minimized during material loading /
unloading operations.
5.3.2.2 WATER ENVIRONMENT Total water requirement for operation phase of the proposed project is
estimated at 21.5 cu. mt. per day and is proposed to be met through
own bore-well.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 126 }
SPPL
To compensate and mitigate impact on ground water availability in the
area due to continuous withdrawal of ground water by the project to the
tune of 21.5 cu. mt. Everyday (effective increase of 4.0 cu. mt. per
day), a rain water recharge scheme has been developed and its details
are given in ANNEXURE - 12.
Treated industrial effluent (3.5 cu. mt. per day) will be incinerated in the
in-house incinerator. Similarly, domestic sewage (1.7 cu. mt. per day)
will be disposed off through septic tank / soak pit system.
5.3.2.3 SOLID WASTE
Hazardous wastes i.e. used oil and solvent residue will be stored in
200 liter MS barrels while ETP sludge and spent Carbon / Hyflow
etc. will be stored in polythene bags.
Above stated hazardous wastes along with discarded drums / containers will be stored separately in the existing “Solid Waste Storage Area” within the factory premises. It has non – percolating R.C.C. floor, covered roof and leachate collection system. The storage area has proper illumination and ventilation and equipped with fire extinguisher device wherever required. A sign – board is put out-side the storage area marked “Hazardous Waste Storage Area” and “Danger”. Area of this storage site is approx. 30 m2 and volume approx. 100 m3.
Hazardous wastes will be disposed in following manner :
used oil will be given to CPCB registered recycler / re-processor of oil.
Solvent residue will be incinerated in in-house incinerator or will be given to common incineration facility of BEIL at Bharuch, Gujarat.
ETP sludge and spent Carbon / Hyflow will be disposed off into
TSDF of NEPL at Ahmedabad.
Discarded containers after decontamination will be given to registered vendor.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 127 }
SPPL
5.3.2.4 NOISE ENVIRONMENT
Following precautionary measures will be adopted to control the noise level :
o Roof of buildings is constructed of reinforced concrete.
o Walls and ceilings of buildings will be lined with sound absorbing materials,
wherever required.
o Noise generating sources will be maintained properly to minimize noise
generated by them.
o Personnel working near the noisy machines in different plant locations will be
provided with well designed ear muffs / plugs (effective noise reduction 10-15
dBA).
o Green belt will act as a noise barrier.
o Training will be imparted to personnel to generate awareness about effects of
noise and importance of using PPEs.
5.3.2.5 LAND ENVIRONMENT
There will be no net increase in air pollution due to manufacture of
proposed bulk – drugs as outlined in Chapter – 4 of this report.
All the hazardous wastes to be generated from the project will be
properly stored and disposed off.
Treated industrial effluent will be incinerated in in-house incinerator.
Domestic sewage will be disposed off through septic tank / soak pit
system.
Thus, no impact on land is envisaged due to discharge of gaseous
emission, solid waste or liquid effluent from the proposed unit.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 128 }
SPPL
5.3.2.6 BIOLOGICAL ENVIRONMENT
5.3.2.6.1 GREEN BELT DEVELOPMENT
Development of green belt contributes to aesthetic improvement of an area
and also helps in controlling air pollution. Trees of a green belt, due to
large surface area of their leaves, collectively provide a natural basin
for various air pollutants. A well developed green-belt helps in
intercepting particulate matter and gaseous pollutants and obstructs
their passage to the ground. Trees also provide cushion in the event of
any sudden discharge of pollutants.
The plantation at the project site consists of Chiku (Manilkara zapota L), Limbdo
(Azadirachta indica A.Juss), Gulmahor (Delonix regia(Boj)) and Badam (Terminalia
catappa L.). Further plantation, if required, will be carried-out after interaction
with local experts and various species will be selected as per CPCB
guidelines.
An important aspect of a greenbelt is that the plants are living organism with
their varied tolerance limit towards the air pollutants. A green belt is effective
as a pollutant sink only within the tolerance limit of constituent plants.
Planting few, known pollutant sensitive species along with the tolerant species
within a green belt is desirable.
5.3.2.6.2 SELECTION OF TREES For development of greenbelt it is advisable to avoid mono culture of tree
specie due to climatic and other reasons. Instead, planting of varieties of tree
species should be planned to take advantage of diversity and uniform up take
of nutrients etc.
In general, following factors have been considered for the selection of
tree species for plantation at the plant site :
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 129 }
SPPL
The trees must be tolerant to all the pollutants present in the
area.
The trees should be able to grow and thrive on soil.
The trees should maintain ecological, land and hydrological
balance of the region.
The trees should be fast growing and indigenous.
Characteristics of plants mainly considered for affecting absorption of
pollutant gases and removal of dust particle are as follows.
For absorption of Gases :
1) Tolerance towards pollutants in question, at concentrations that are not too
high to be instantaneously lethal
2) Longer duration of foliage
3) Freely exposed foliage
4) Adequate height of crown
5) Openness of foliage in canopy
6) Big leaves( long and broad laminar surface)
7) Large number of stomatal apertures
Plantation along road sides
Automobiles are the source of pollution of gaseous and particulate pollutants.
Component of green belt on road side hence should be with both absorbers
of gases as well as of dust particles. The choice of plants for road side should
include shrubs of height 1 to 1.5 meter and trees of 3-5 meter height. Medium
sized trees, alternating with shrubs are ideal for sorption of particulates and
gases.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 130 }
SPPL
TABLE NO. 5.1
RECOMMENDED PLANT SPECIES FOR GREEN BELT DEVELOPMENT Plant species Habit Tolerance
limit To Dust
Stomatal index
Mode of Regeneration
Acacia auriculiformis Tree Tolerant 10.9 Seeds Acacia catechu Tree 8.24 seeds Acacia leucocephala ( Hari baval)
Shrub T 12.01 seeds
Ailanthus excelsa Tree T 13.01 Seeds, shoot, root cuttings
Albizia lebbeck Tree T 19.72 Seeds Albizia procera Tree T 20.21 seeds Alstonia scholaris ( Devil- tree) Tree T 15.23 Seeds Annona squamosa (Seetaphal) Small tree T 26.19 Seeds, Grafting Anogeissus latifolia (Dhavdo) Tree T 18.72 Seeds Azadirachta indica Tree T 29.2 Seeds Bauhinia purpurea Tree T 23.58 Seeds Bauhinia racemosa (Aasundro) Small tree T 25.68 seeds Bougainvillea spectabilis Shrub T 32.53 Cutting Caesalpinia pulcherrima (White gold mohur)
Tree T 29.09 Seeds and Cuttings
Calotropis gigantea Shrub T 9.93 Seeds Calotropis procera Shrub T 10.32 Seeds Cassia fistula Tree T 20.4 Seeds and
suckers Cassia siamea Tree T 21.2 Seeds Cordia dichotoma (Gunda) Tree T N.A Seeds/ stem
cuttings Delonix regia ( Gulmohur) Tree Sensitive 14.38 Seeds /stem
cutting Emblica officinalis( Amli) Tree T 11.62 Seeds /stem
cutting Euphorbia tirucalli Shrib T NA Cuttings Ficus bengalensis (Vad) Tree T 21.72 Seeds /stem
cutting Ficus hispida Tree T 17.21 Seeds /stem
cutting Ficus religiosa (papal) Tree T 18.70 Seeds /stem
cutting Hibiscus rosa-sinensis Small tree T 23.32 stem cutting Ixora arborea Small tree T 17.3 stem cutting Ixora rosea Small tree T 20.30 Stem cutting Jatropha curcas Shrub T NA Lantana camara Shrub T 12.13 Seeds /stem
cutting Lawsonia inermis (Mendi) Shrub T 17.0 Seeds /stem
cutting
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 131 }
SPPL
Mangifera indica ( Am) Tree T 30.77 Seeds/ grafting/ budding/
Manilkara zapota (Chikoo) Tree T 25.78 Grafting Melia azadirachta Tree T Seeds /stem
cutting Nerium indicum Shrub T 15.7 Cutting Peltophorum pterocarpum Tree T 16.68 Seeds Polylathia longifolia Tree T 22.27 Seeds Sesbania sesban ( Shrub T 19.2 Seeds Tamarindus indica Tree T 18.4 Seeds Tectona grandis Tree T 23.48 Seeds Terminalia alata Tree T NA Seeds /stem
cutting Thespesia populnea Tree T 29.81 Seeds /stem
cutting Thevetia peruviana Shrub T 27.8 Seeds /stem
cutting Zizyphus mauritiana (Bordi) Tree T 12.4 Seeds /stem
cutting
T: Tolerant, NA =Not available Highlighted species are most suitable for this locality, considering its terrain and other existing vegetative cover in the study area Sources: CPCB (March ,2000) PROBES/75/1999-2000 PLANTATION AREA About 4,000 m2 of land is allocated for greenbelt / green cover development
at the project site of SPPL. Proper budgetary provision considering expenses
incurred on saplings, soil handling, manuring, after care and maintenance is
made.
5.3.2.7 SOCIO – ECONOMIC ENVIRONMENT
SPPL is committed to the socio – economic up-lift of the area and has
donated computer to the school of the nearby village of Varsola and has also
contributed towards face lift and upkeep of crematorium of Vil. : Varsola.
Moreover, various modes of indirect employment i.e. transportation,
increased business opportunities to shopkeepers etc. will also be there.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 132 }
SPPL
5.3.2.8 HEALTH AND SAFETY
Following measures will be adopted in the plant :
Regular inspection and maintenance of pollution control systems.
All measures related to safety such as safety appliances, training,
safety awards, posters, slogans are undertaken.
The workers exposed to noisy sources are provided with ear
muffs/plugs.
Adequate facilities for drinking water and toilets are provided to the
employees.
The fire and safety equipments are properly utilized and maintained
regularly.
The health of the workers will be regularly checked by a well qualified
doctor and proper records will be kept for each worker.
Isolated storage for all hazardous chemicals with adequate safety
measures, sign board outside storage etc.
Fire – proof electric fittings will be used.
Good air circulation will be ensured within the plant area.
Workers will be provided training to deal with emergency situation, to
operate fire extinguishers, to provide first – aid to affected persons by
arranging safety work-shop once in six months.
Showers and hand – wash will be provided in vicinity of work area with
ample quantity of water available.
Fire and Smoke detectors will be installed at suitable place in the
premises to get alert warning and avoid major accident.
On site emergency plan will be prepared and implemented to safe guard
human life and property.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 133 }
SPPL
Moreover, SPPL based on past occupational health record of its’ existing unit, does not anticipate any adverse effect on health of workers.
5.3.2.9 GENERAL CONSIDERATIONS
For good house keeping of the project, following measures will be
planned :
Maintaining cleanliness of roads to prevent accumulation of dust
and waste material.
Inculcating positive attitude among employees for good house –
keeping.
Maintaining hygienic conditions near drinking water source and
toilets.
5.3.2.10 Waste - minimization, Recycle / Reuse / Recover Techniques, Energy Conservation & Natural Resource Conservation :
Unit will take following steps in this regard :
1. Recovery of solvents will be more than 95 % and these recovered
solvents will be recycled back to the process.
2. High efficiency pumps with auto level cut off will be installed.
3. Liquid chemicals dosing will be through metering pumps.
4. CFLs with high frequency ballast shall be used.
5. Energy efficient fluorescent tube lights (T-5)/ CFL shall be used for
office areas.
6. Self starters and variable drives will be installed for motors.
7. All tanks will be installed with level controllers and cut off for pumps.
8. Process improvement by R & D to reduce waste water generation.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 134 }
SPPL
5.4 Environmental Management Cell
In addition to preparing an EMP, it is also necessary to have a permanent
organizational set up to ensure its effective implementation. Hence, SPPL will
create a team consisting of officers from various departments to co-ordinate
the activities concerned with management and implementation of the
environmental control measures. This team will undertake the activity of
monitoring the stack emissions, ambient air quality, noise level etc. either
departmentally or by appointing external agencies wherever necessary.
Regular monitoring of environmental parameters will be carried - out to find
out any deterioration in environmental quality and also to take corrective
steps, if required, through respective internal departments.
The Environmental Management Cell will also collect data about health of
workers, green belt development etc. Organogram of the Environmental
Management Cell is presented in FIGURE NO. – 5.1.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 135 }
SPPL
FIGURE NO. 5.1
ORGANISATIONAL SET UP FOR ENVIORMENTAL MANAGEMENT PLAN
Environment Management Cell
The cell will also be responsible for monitoring of the plant safety and safety
related systems which include :
Checking of safety related operating conditions.
Visual inspection of safety equipments.
Preparation of a maintenance plan and documentation of maintenance
work specifying different maintenance intervals and the type of work to
be performed.
Other responsibilities of the cell will include :
Conduct and submit annual Environmental Audit (in Form – V). A
Director
Dy. Manager (Env.)
Asst. Manager (Safety)
Officer (Safety)
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 136 }
SPPL
GPCB registered agency will be retained to generate the data in
respect of air, water, noise, soil and meteorological data and prepare
the Environmental Audit report. This report will be submitted to the
GPCB every year before 30th September. Timely renewal of
Consolidated Consents & Authorization (CC & A) will also be taken
care of.
Submitting environmental monitoring report to GPCB. Data monitored
by the cell will be submitted to the Board regularly and as per the
requirement of GPCB. The cell will also take mitigative or corrective
measures as required or suggested by the Board.
Keeping the management updated on regular basis about the
conclusions / results of monitoring activities and propose measures to
improve environment preservation and protection.
Conducting regular safety drills and training programs to educate
employees on safety practices. A qualified and experienced safety
officer will be responsible for the identification of the hazardous
conditions and unsafe acts of workers and advise on corrective
actions, organise training programs and provide professional expert
advice on various issues related to occupational safety and health.
Conducting safety and health audits to ensure that recommended
safety and health measures are followed.
5.5 Monitoring Of Environment
A regular monitoring of environmental parameters like air, water, industrial
effluent, noise and soil as well as performance of pollution control facilities
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 137 }
SPPL
and safety measures in the plant are important for proper environmental
management of any project. Therefore, the environment and safety cell will
handle monitoring of air and water pollutants as well as the solid wastes
generation as per the requirements of Gujarat Pollution Control Board and
Central Pollution Control Board.
ADVANTAGES OF MONITORING : Monitoring of various parameters will be carried out regularly to :
find out pollution level inside the plant and in nearby area compile pollution related data for remedial measures find out efficiency level of pollution control measures adopted
TABLE 5.2 MONITORING SCHEDULE FOR ENVIRONMENTAL PARAMETERS
Sr. No.
Partiulars Monitoring Duration Important Parameters
1 AIR POLLUTION A Scrubber Monitoring Once in a
month Grab HCl
B Incinerator stack Once in a month
Grab PM, SO2 & NO2
C Ambient Air Quality (i) At 1 location inside the Plant
Premises Once in a month
24 hrs Continuously
PM2.5, PM10, SO2, NO2 & HCl
(ii) At 1 location in Prevalent Down Wind Direction
Once in a month
24 hrs Continuously
PM2.5, PM10, SO2, NO2 & HCl
(iv) At 1 location in Up Wind Direction
Once in a month
24 hrs Continuously
PM2.5, PM10, SO2, NO2 & HCl
2 WATER QUALITY A Water Quality in the Study Area (i) Ground Water inside the plant
premises Once in a month
Grab pH, Colour, Turbidity, TSS, TDS, COD, Chlorides, Sulphates, Total Alk., Ca & Mg
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 138 }
SPPL
Hardness, Fluoride etc. (ii) Ground Water out side the plant
at 1 location Once in a month
Grab -- do --
3 INDUSTRIAL NOISE LEVELS
At various locations within premises
Once in a month
24 hrs Continuous with
one hour interval
Noise Levels in dB(A)
Laboratory Facilities No separate laboratory facility for analysis of above stated parameters will be
created by SPPL looking to the size of the project. Instead, services of a
GPCB registered laboratory will be taken for this purpose.
5.6 BUDGETORY PROVISIONS FOR EMP Adequate budgetary provisions have been made by SPPL management for
execution of environmental management plan. The details of capital and
recurring (per annum) budget earmarked for pollution control, operation and
maintenance of pollution control facilities, for greenbelt development and
maintenance will be as given in TABLE NO. 5.3 below :
TABLE NO. 5.3 Cost of environmental protection measures (Rs. in Lakhs)
Sr. No.
Capital Cost Recurring cost per Annum
1. Air Pollution Control 1.00 2.50 2. Water Pollution Control 3.00 25.00 3. Noise Pollution Control 0.50 0.25 4. Environment Monitoring and
Management 0.00 1.50
5. Occupational Health 1.00 0.50 6. Green Belt 5.00 1.50
TOTAL 10.50 31.25
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 139 }
SPPL
CHAPTER – 6
RISK ASSESMENT & DISASTER MANAGEMENT PLAN
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 140 }
SPPL
6.1 RISK ASSESSMENT The bulk – drug project of SPPL will store, handle and consume a no. of
flammable chemicals. Hence, a consequence analysis has been carried – out
related to accidental fire and explosion exposure of the proposed ‘Storage
Shed’ which would be used for storage of flammable chemicals.
As per Loss Prevention in Process Industries by Frank E. Lees, drum failures
accounts for around 76 accidents out of 2108 accidents in Chemical
Industries.
The accidental occurrence of fire or explosion in the proposed storage shed
could cause strain on the operational activity of the project. Hence, the main
purpose of consequential effect analysis is to provide useful tool for mitigation
of adverse effect of occurrence of accidental fire or explosion involving
‘Storage Shed’
For the purpose of consequence analysis, internationally renowned fire &
explosion evaluation software developed by “Swiss Re” known as “ExTool”
has been used.
6.1.1 CONSEQUENCE ANALYSIS
The project will store, handle and consume a no. of flammable chemicals. List
of such chemicals is given in TABLE NO. 6.1. Properties related to fire and
explosion hazards of these chemicals are given in TABLE NO. 6.2. The
chemicals would be stored mostly in 200 ltrs. drums. However, some of the
chemicals will also be stored in smaller drums of capacity 10 ltrs., 20 ltrs. etc.
All such drums will be stored in a designated place to be known as ‘Storage
Shed’ of area 66 sq. mt. (12 m. x 5.5 m.). The Storage Shed is shown on the
lay – out of the project given at FIGURE NO. 6.1.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 141 }
SPPL
The ‘Storage Shed’ will be located atleast 30 mtrs. away from the
manufacturing process block.
Following constructional features are presumed for the shed :
• ‘Storage Shed’ will be a pucca room of RCC construction.
• Flooring will be provided with 10 cm high kerbing all around and will be
connected to proper draining facility.
• The slope of the flooring of the Storage Shed would be towards the entry door
and the door would not be provided any door sill foe easy movement of
materials.
• The front yard of the Storage shed would be paved along the length of the
Spare Room (12 meters) and breath of the front yard assumed to be around 3
meters. The total paved area in front of the Spare room would be (12mX3m)
36 sq. mt.
FIGURE NO. 6.1
30 mtr.
Storage shed
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 142 }
SPPL
TABLE NO. 6.1
List of Flammable Chemicals
Name of Hazardous Chemical Storage No for Drums / Bag
Unit Qty. No of
Container
Type
Acetic Acid Kg 500 15 Carboys
Acetone Ltr 1800 9 Drums
Acrylonitrile Kg 320 2 Drums
Methanol Ltr 1000 4 Drums
Iso Propyl Alcohol Ltr 600 8 Drums
Benzyl Chloride Kg 300 10 Carboys
Pyridine Kg 200 1 Drum
Tetra Hydrofurane Ltr. 200 1 Drum
Toluene Ltr. 200 1 Drum
N- Hexane Ltr. 400 2 Drums
Ethyl Acetate Ltr. 800 4 Drums
Acetonitrile Ltr. 200 1 Drum
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 143 }
SPPL
TABLE NO. 6.2
Fire and Explosion Related Properties of Flammable Chemicals
Sr.
No.
Hazardous Chemical Flash Point 0C
Lower
Flammability
Limit %
Upper
Flammability
Limit %
1 Acetic Acid 39 6.0 17.0
2 Acetone - 18 2.2 13.0
3 Acrylonitrile 0 3.0 17.0
4 Methanol 12 5.5 44
5 Iso Propyl Alcohol 12 2.0 12
6 Benzyl Chloride 67 1.1 14.0
7 Pyridine 20 1.8 12.4
8 Tetra Hydrofurane - 14 1.5 12.0
9 Toluene 4.4 1.1 7.1
10 N- Hexane - 32 1.0 7.0
11 Ethyl Acetate - 4 2.2 11.5
12 Acetonitrile 12.8 3.0 16.0
6.1.2 LOSS SCENARIOS
The consequence analysis of the fire & explosion scenario is based on the
visualization of Most Credible Loss Scenario (MCLS) development and
subsequent modeling of the same scenario to carry out further analysis.
The MCLS visualized for the ‘Storage Shed’ are as under : It is envisaged that a few 200 lit highly flammable liquid drum (may be toluene or IPA) would leak heavily may be due to bottom corrosion and would flow through the gap between floor and the door due to absence of any door sill and form a pool of flammable liquid in entire front paved yard (36 sq. mt.) of the Storage Shed. Following two sub scenarios are highly expected under this circumstance:
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 144 }
SPPL
a. Scenario 1. There could be huge fire due to ignition of entire pool of
flammable liquid engulfing 36 sq. mt. of area.
b. Scenario 2. Formation of a flammable vapour cloud due to rapid
evaporation of flammable liquid and subsequent Vapour Cloud Explosion
(VCE).
To be conservative, it is assumed that content of at least one 200 litre drum of Acetone / Methanol /Hexane would form vapour cloud and cause Vapour Clod Explosion (VCE)
The scenarios envisaged are based on recorded past experiences with an
objective to simulate the effect of probable maximum damage that could be
caused by such accidents.
The internationally renowned fire & explosion evaluation software developed
by “Swiss Re” known as “ExTool” has been used for analyzing consequences
of visualized MCLS.
6.1.2.1 Interpretation of Data
Fire
The heat radiation effects scenarios like Pool fire have been evaluated based on following standard effects built-in in the computer programme. (ExTool) For radiation intensities > 3.6 W/sq. cm. fire will propagate For intensities between 1.2 and 3.0 W/sq. cm. no propagation if enough cooling water is applied For radiation intensities < 0.8 W/sq. cm. no propagation For fire-fighters : 0.8 W/sq. cm. Absolute approach limit 0.5 W/sq. cm. Limit with normal protective clothing Blistering on skin in 30 sec. Pain on skin in 10 sec. 0.15 W/sq. cm. Limit without protective clothing Reference API
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 145 }
SPPL
Explosion
The evaluation of the effect of VCE has been carried out based on reference
standard effects built-in in the computer programme which is as under.
Mbar (Level of Over-
pressure)
Effect of Explosion
1.4 Annoying noise
3 Loud noise
7 – 10 Window pane 5% broken
14 – 30 Window pane 50% broken; some damage to ceilings & tiling
30 – 60 Window pane 90% broken; minor structural damage
30 – 50 Tiles displaced
60 – 90 Doors and window frames broken
70 – 140 Corrugated steel or aluminum panel’s fastenings fail; steel
frame of clad building slightly distorted.
140 – 200 Non-reinforced concrete walls shattered; steel frame buildings
suffer heavy damage or distortion
140 – 280 Partial or total collapse of roof, partial demolition of one or two
external walls, severe damage to load-bearing partitions.
350 – 800 50 – 75% of external brickwork destroyed
800 – 2600 Almost complete demolition of houses
700 – 1700 Telegraph poles destroyed
1700 – 3800 Large trees destroyed. Ref. Lees - Loss prevention in Process Industries, & Sixth Int. Mtg of Forensic Sciences Edinburgh (19720)
However for the purpose of realistic interpretations and to asses the quantum
of damage, following scale is used (Development of Over Pressure Vs
probable damage percentage).
Over Pressure (mbar) Expected Damage % 0.02 5% 0.13 40% 0.20 80%
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 146 }
SPPL
6.1.3 Results :
Fire (Scenario 1)
Scenario : Fire in the front yard of Storage Shed.
Formation of huge pool of highly volatile & flammable liquid in front yard of the Storage Shed due to considerable leakage of drum stored and subsequent ignition of accumulated pool of flammable liquid. The probable effects of the fire scenario are enumerated below in TABLE NO. 6.3 graphical presentation of computer output is given in FIGURE NO. 6.2. While modeling the scenario, following points are assumed
• The equivalent area of the pool of fire is considered as circular area of radius
3.38 mt. (area - 36 sq. mt.)
• Property of light hydrocarbon has been considered as fire property
TABLE NO. 6.3
Effect of the Heat Flux for Fire Propagation
Radiation Energy level W/cm2
Distance in meter
3.60 10 3.0 11 1.2 190.8 24 0.5 31 1.5 58
Explosion (Scenario 2)
Scenario : Vapour Cloud Explosion
It is envisaged that due to formation of vast pool of highly volatile flammable
liquid in front yard of Storage Shed, vapour cloud would form and result into
Vapour Cloud Explosion (VCE). While modeling VCE, it is assumed on very
conservative basis that the content of at least one drum that is around 200
lits. (equivalent to around 5% of the amount of flammable liquid proposed to
be stored in Storage shed) of flammable chemical would be the mass of the
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 147 }
SPPL
vapour cloud. The properties of n-Hexane have been taken as standard for
modeling. Results of VCE scenario envisaged are enumerated in TABLE NO.
6.4 below and graphical presentation of computer output is given in FIGURE
NO. 6.3 :
TABLE NO. 6.4
Result of VCE
Over Pressure bar Damage Distance,
in meter
Expected Damage %
0.02 53 5%
0.13 34 40%
0.20 19 80%
6.1.3.1 INTERPRETATION OF THE RESULTS
It can be inferred from the VCE results that even if content of only one highly
flammable liquid forms a vapour cloud and subsequently ignited to result into
VCE in front of the Storage Shwed, considerable damage (around 40%) is
expected to be caused to the production blocks located 30 meters away from
the Storage Shed (critical distance is 34 meters) used for hazardous
chemicals storage. However, no appreciable damage is expected to the
production blocks if fire breaks out in front of the Spare Room due to
formation of pool of highly flammable liquid. (critical distance from fire point of
view is only 11 m).
As practically no buffer distance is available in case of occurrence of VCE, it
is better to incorporate all the safety norms as standard operating procedure
while handling the hazardous chemicals in the Storage Shed. Therefore,
considering all the practical aspects, the distances proposed in the layout
plan from the process blocks to Storage Shed appear to be very safe from fire
point of view but not from VCE angle.
Fire may also travel through drains located in the vicinity of Storage Shed.
Therefore, incorporation of flame trap in the drain close to Storage Shed is
suggested.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 148 }
SPPL
FIGURE NO. 6.2
Graphical representation of effects of fire
FIGURE NO. 6.3 Graphical representation of VCE
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 149 }
SPPL
6.2 DISASTER MANAGEMENT PLAN
6.2.1 INTRODUCTION
Disaster
An emergency is said to have arisen when operators in the plant are not able to
cope up with a potential hazardous situation i.e. loss of control of an incident
causes the plant to go beyond its normal operating conditions, thus creating
danger. When such an emergency evolves, chain of events affect the normal
working within the factory area and / or which may cause injuries, loss of life,
substantial damage to property and environment both inside and outside the
factory and a DISASTER is said to have occurred.
The various steps involved in the process of DISASTER MANAGEMENT can
be summarized as :
(1) Minimize Risk Occurrence (Prevention)
(2) Rapid Control (Emergency Response)
(3) Effectively Rehabilitate Damaged Areas (Restoration)
Disaster Management Plan is evolved by careful scrutiny and interlinking of :
(a) Types and causes of disaster.
(b) Technical know – how.
(c) Resource availability.
Types of Disaster
The various types of Disaster that may occur are :
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 150 }
SPPL
(i) Due to fire and
(ii) Hurricane, cyclone and other natural calamities.
6.2.2 OBJECTIVES OF PLAN
This plan is developed to make best possible use of resources at the command
of SPPL to :
Rescue the victims and treat them suitably.
Safeguard others (evacuating them to safer places).
Contain the incident and control it with minimum damage.
Identify the persons affected.
Preserve relevant records and equipment needed as evidence incase on
an inquiry.
Rehabilitate the affected areas.
6.2.3 IDENTIFICATION OF MAJOR HAZARDS
• Fire Hazard.
6.2.4 SCOPE OF PLAN
The plan will set into action immediately after a fire occurs inside the plant.
However, as stated in risk assessment, fire hazard will be restricted to area
surrounding storage shed.
6.2.5 BASIS OF PLAN
SPPL will prepare an onsite emergency plan. The basic guidelines of the plan
are as given below :
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 151 }
SPPL
1) Informative brochure on emergency will be distributed to each staff
member of the plant and telephone numbers of key personnel to be
contacted during an emergency will be placed at all the operator
placement point in the plant.
2) SPPL will have a direct tele-link service line with the nearest Fire Station in
case of severe emergency.
3) Workers would be trained regularly on fire hazard drill, which will be
organized once in a month by the safety and fire department.
4) Various locations would be covered with fire hydrant systems that would
be tested and put into operation in such a manner that it remains
operational during emergency.
5) 24 hours vehicle for service and in – plant first aid emergency kit would be
provided.
6) Coded colours for pipeline will be used as per IS.
6.2.6 POST DISASTER ANALYSIS AND EVALUATION
When an emergency is over, it is desirable to carry out a detailed analysis of
the causes of the accident to evaluate the influence of various factors involved
and to propose methods to eliminate or minimize them in future.
Simultaneously, the adequacy of the disaster preparedness plan will be
evaluated and any short comings will be rectified.
6.2.7 GENERAL RECOMMENDATIONS
All non – routine work etc. should be carried out under a permit system.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 152 }
SPPL
Adequate number of caution boards high lighting the hazards of chemicals
to be handled, eye baths and emergency showers should be provided at
critical locations.
Adequate number of absorbents should be placed at accessible locations
in the storage shed area that would enable to contain spills immediately.
Adequate colour coding and labeling of the pipelines should be provided
for easy identification of products proposed to be handled through them.
The damage distance due to any failure could be reduced, by reducing the
time required to stop the leak, which in turn would reduce the quantity of
spillage. The response time could be reduced by installing / maintaining
instruments, effective communication system, etc.
It is recommended that rubber mats be provided in front of electrical panel
of the entire plant with a view to prevent employees from receiving electric
shocks.
It is suggested that all type of fire extinguishers be placed at appropriate
places for easy access in case of emergency.
6.2.8 THE AVAILABILITY, ORGANIZATION, AND UTILIZATION OF RESOURCES
FOR EMERGENCIES
In order to maintain emergency response capability, certain facilities must be
kept in a state of readiness, and sufficient supplies and equipment must be
available. Emergency hardware can be classified according to its use during
the response operations. Typical examples are :
Emergency Operation Centres
Communication equipment
Alarm systems
Personal Protection Equipment
Fire fighting facilities, equipment and supplies
Spill and vapour release control equipment and supplies
Medical facilities, equipment and supplies
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 153 }
SPPL
Monitoring systems
Transportation systems
Security and access control equipment
It is the responsibility of the Plant Management to ensure that the appropriate
equipments and materials are available to respond to hazard – specific
emergencies at the site.
6.2.9 COMMAND, CO – ORDINATION AND RESPONSE ORGANIZATION
STRUCTURE
One of the most important objectives of emergency planning is to create a
response organization structure capable of being deployed in the shortest
possible time during an emergency.
Command and control of an emergency condition encompasses the key
management functions necessary to ensure safeguard of the health and safety
of employees, as well as the public living in the vicinity. These primary functions
are summarized as follows :
a) Detection of the emergency condition
b) Assessment of the condition
c) Classification of the emergency
d) Mitigation of the emergency conditions
e) Notification to management personnel
f) Notification to local, state and governmental agencies
g) Activation and response of the necessary onsite and off – site support
personnel
h) Continuous assessment and reclassifications, as necessary
i) Initiation of protective actions
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 154 }
SPPL
j) Aid to affected personnel
k) Recovery and re – entry
The key personnel are nominated with special responsibility according to the
laid down procedures and to make the best use of available resources. The
key personnel are as under :
- Alarm Raiser
- Incident Controller
- Deputy Incident Controller
- Site Main Controller
- Essential Workers
- Other key personnel.
The responsibilities of the above key personnel are as described below :
6.2.9.1 ALARM RAISER
Any person who notices any abnormal incident of hazardous nature will raise
an alarm to make people aware of the scenario. His responsibilities are :
(1) As soon as he notices any incident of hazardous nature i.e. fire,
liquid spillage etc., he will first inform to his superior and co –
worker.
(2) If the hazard is minor, he will try to prevent by using internal resources like
fire extinguishers in case of fire, cover the spillage by sand in case of
liquid spillage.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 155 }
SPPL
(3) If the incident of hazard is major, raise the siren or press the emergency
siren button provided, or ring the bell loudly in case of failure of power
supply.
6.2.9.2 INCIDENT CONTROLLER (IC)
His responsibilities include :
(1) As soon as the sound of siren or bell is heard, he will arrive at the
site of incident.
(2) Take the charge of the scene of the incident.
(3) To assess the scale of emergency. If the emergency is minor, he will start
to activate on – site plan.
(4) As per the incident, direct the essential workers to prevent it by using
extinguishers in case of fire; by covering the liquid spillage by sand or
suitable material in case of liquid spillage.
(5) To send telephonic message to Site Main Controller and key personnel.
(6) Direct the shut down of the plant or part of the plant and evacuate the
plant personnel to assembly point.
(7) Direct all operations within the affected areas with the following priorities.
(a) Secure the safety of personnel.
(b) Minimum damage to plant, property and environment.
(c) Minimize loss of material.
(8) To search for casualties.
(9) To brief Site Main Controller and keep informed of development of situation.
(10) To preserve evidence that will be necessary for subsequent inquiry into
the cause of the emergency and concluding preventive measures.
The Incident Controller shall wear Blue Helmet for his easy identity by all
concerned at the time of emergency.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 156 }
SPPL
6.2.9.3 DEPUTY INCIDENT CONTROLLER (DIC)
In the absence of Incident Controller, the Deputy Incident Controller will
assume the responsibilities of the Incident Controller as given above.
6.2.9.4 SITE MAIN CONTROLLER (SMC)
He is the head authority of the Organization. The technical director holds the
responsibility of the Site Main Controller. He will have over all responsibility for
directing operation and calling for outside help.
The Site Main Controller shall wear White helmet for his easy identification.
The responsibilities and duties of the Site Main Controller include :
(1) Relieve the Incident Controller of his responsibilities of over all charge of
Main Control.
(2) On consultation with Incident Controller and other key personnel, decide
about the type of emergency.
(3) To ensure that key personnel are called in.
(4) To continuously review and assess possible developments to determine
the most probable cause of events.
(5) To direct the safe closure of the plant and evacuate the plant in
consultation with the Incident Controller and other key person.
6.2.9.5 ESSENTIAL WORKERS (EW)
As soon as the Essential Workers hear the emergency siren or any emergency
brought to the knowledge, they will first report to the Incident Controller.
The team of Essential Workers trained in fire fighting, spill control and first – aid
will be made available in the factory round the clock in all shifts.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 157 }
SPPL
Their responsibilities include :
(1) To fight fire or spill control till a fire brigade takes the charge.
(2) To help the fire brigade and mutual aid teams.
(3) To do emergency engineering work like isolation of equipment, materials,
process, providing temporary by-pass line for safe transfer of materials,
urgent repairs and replacement, electrical work etc.
(4) To provide emergency services like power, water, lighting, instruments,
equipment etc.
(5) To move equipment, special vehicles and transport to or from the scene of
incident.
(6) To provide first aid and medical help.
6.2.9.6 OTHER KEY PERSONNEL
Other key personnel are required to provide advice and to implement the
decisions taken by the Site Main Controller in the light of information received
on the situation from the site emergency.
All key personnel will wear Red Helmet for their identification and easy
recognition. The responsibilities and duties of key personnel include :
(1) SAFETY :
The Safety Officer / Supervisor will carry out the following :
(a) To provide necessary equipment like Fire Fighting Equipment (FFE)
and Personal Protective Equipment (PPE).
(b) To accompany Factory Inspector during investigations of the
emergency.
(c) To train workers / supervisors in safety and safe operating
procedures.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 158 }
SPPL
(d) To assist the Site Main Controller, Incident Controller in preparing a
brief report of the incidents.
(2) ASSEMBLY POINTS :
The Assembly Points for gathering non – essential workers / persons will
be fixed and will be clearly marked as per the wind direction.
(3) FIRE CONTROL ARRANGEMENTS :
Fire fighting trained personnel will be made available in all the shifts. The
responsibilities and duties include :
(a) To fight the fire with available internal Fire Fighting Equipment and to
stop leakage of liquids etc.
(b) To provide Personal Protective Equipment to the team.
(c) To cordon the area and inform Incident Controller or Site Main
Controller about the development of emergency.
(d) To train personnel (Essential Workers) to use Personal Protective
Equipment and Fire Fighting Equipment.
(4) MEDICAL ARRANGEMENT :
The responsibilities and duties include :
(a) To provide first aid to the affected persons, and, if necessary, send
them to hospitals for further treatment.
(b) To keep a list of blood groupings ready and updated.
(5) TRANSPORT AND EVACUATION ARRANGEMENT :
For transportation of people, company’s vehicles will be utilized.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 159 }
SPPL
ANNEXURE – 1
CONSOLIDATED CONSENTS AND AUTHORISATION (CC&A) ISSUED BY GPCB FOR EXISTING PRODUCT
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 160 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 161 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 162 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 163 }
SPPL
ANNEXURE – 2 MANUFACTURING PROCESS WITH MASS
BALANCE
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 164 }
SPPL
ANNEXURE – 2
MANUFACTURING PROCESS ALONGWITH MASS BALANCE
PRODUCT : FAMOTIDINE Brief Process :-
Stage – I 1,3 Dichloro Acetone reacts with Gunyl Thiourea in presence of Acetone and catalyst. Contents are maintained for 16 hrs. and Stage – I compound is obtained. Stage – II & III
Stage - I dissolved in water further reacts with Thiourea yields in to Di Hydrochloride compound which reacts with IF and caustic solution in presence of Methanol and water to yield crude Famotidine. Stage - IF
Sulfamide is reacted with Acrylonitrile in presence of HCl(g) and product is isolated by centrifuging and washed with Acetone. Stage _ IV
Crude Famotidine is purified in IPA / water to give Purified Famotidine. Stage – V
Once purified, Famotidine is dissolved in water and Acetic Acid and charcolised, filtered through Hyflow. To clear filtrate, liquor Ammonia ( 20% ) is added & adjusted pH 8.0 to get the pure Famotidine.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 165 }
SPPL
Famotidine Process Flow Diagram With Consumption per Kg of Famotidine STAGE - I 1,3 Dichloro Acetone (0.588k) (3.53ltr.) Acetone Gunyl Thiourea (0.564k) (0.0235k) Potassium Iodide Acetone recovery( 3.176L) Residue To Solid Waste (0.5L)
St - I Hydrochloride Compound (1.03K) STAGE – II & III Methanol (5.647L) (0.77K) Caustic Flakes Thiourea (0.329K) (5.647L) Water IF (1.13K) Methanol-WaterRec( 6.47L) To ETP (6.97L) Crude Famotidine (1.117K)
S S R
S S R
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 166 }
SPPL
STAGE – IV (11.176L) IPA-water
Crude Famotidine (1.117K)
IPA-Water recovery( 10.88L) To ETP (0.35L)
Purified Famotidine (1.06K) STAGE - V
Liq. Ammonia (0.682L) Hyflow (0.03K) (0.34L) Acetic Acid (1.41L) Water (Make-up) Charcoal (0.053K)
Recycle (6.0L) Charcoal & Hyflow (0.082K) ML (8.5L) 2.5 L to ETP Pure Famotidine ( 1.0) STAGE - IF Acrylonitrile (2.058K) Sulfamide (0.588K) HCL-30% (11.76L) Acetone (0.588L) Acrylonitrile recovery( 1.476L) HCL-20% (11.76L) Acetone ( 0.53L) Vapour Loss ( 0.09L ) Intermediate Famotidine (1.13)
S S R
S S R
G L R
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 167 }
SPPL
PRODUCT : PREGABALIN
Brief manufacturing process : Stage-I
Salt formation of Hexanoic Acid with R(+) Phenyl ethyl amine by using Chloroform as a media. Isolate wet material by filtration and dry it. It is Pregabalin stage-I.
Stage-II
Breaking of salt (stage-I) by Hydrochloric acid using water as a media. Solid product isolate by filtration at low temperature. Dry this product and then purify in IPA.
Stage-III
Stage-II material is reacted with Bromine in presence of aqueous Caustic solution at lower temperature, then neutralised with Hydrochloric acid and it gives crude Pregabalin. Solid product is isolated by filtration and then dried.
Stage-IV
Purification of crude material in IPA-water mixture with giving charcoal treatment at higher temperature. Precipitate solid at lower temperature and isolate it by filtration. Dry the wet material in dryer. This is final Pregabalin.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 168 }
SPPL
Flow diagram of Pregabalin Stage-I ( all quantities are in Kg ) Chloroform: 77.5 Kg RBF Hexanoic acid(R/S): 4.76 Kg Resolution
R(+)PEA(2.23 Kg) reaction
Reaction mass
Chloroform: 7.0 Kg
Filtration CHLROFORM: 82.13 Kg
recovered and reused
Drying wet cake:5.23 Kg Drying loss: 1.71 Kg Stage-I Dry material: 3.52 Kg S-Salt Stage-II Stage-I: 3.52 Kg RBF Water: 10.57 Kg Salt breaking HCl: 1.11 Kg Reaction water: 2.44 Kg Filtration water : 14.797 Kg HCl: 0.057 Kg To ETP as liquid effluent
Drying wet cake: 2.90 Kg Drying loss: 0.83 Kg
Stage-II crude Dry material: 2.07 Kg
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 169 }
SPPL
Stage-II : Purification: Stage-II Crude: 2.07 Kg RBF IPA: 2.46 Kg Purification IPA: 0.11 Kg Filtration IPA ML: 2.74 Kg
For recovery of IPA
Drying wet cake: 1.9 Kg Drying loss: 0.19 Kg Stage-II Pure Dry material: 1.71 Kg S-isomer
Stage-III (Crude formation) Water 8.57 Kg RBF Sodium 3.57 Kg Hoffman Bromide Solution Stage-II 1.71 Kg Reaction HCl 2.74 Kg Filtration ML+WML: 16.09 Kg Water 0.85 Kg Liquid effluent to ETP
Drying wet cake: 1.35 Kg Drying loss: 0.18 Kg Stage-III Crude Dry material: 1.17 Kg Crude
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 170 }
SPPL
Stage-IV (Purification) RBF Stage-III 1.17 Kg Purification IPA 9.53 Kg Water 4.04 Kg Charcoal 0.057 Kg Filtration Solid : Charcoal: 0.057 Kg Hyflow 0.09 Kg Hyflow: 0.09 Kg IPA 0.55 Kg Water 0.23 Kg Precipitation IPA 0.87 Kg Filtration IPA -WATER: 15.51 Kg Water 0.29 Kg For IPA recovery Drying wet cake: 1.17 Kg Drying loss: 0.17 Kg Stage-IV Pure Dry material: 1.0 Kg Pregabalin
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 171 }
SPPL
PRODUCT : DI BENZOYL LACTUM Brief Process :- Stage – I
D- Mannitol is charged in mixture of 2, 2 Dimethoxy Propane and Di – Methyl Sulfoxide. PTSA is added as a catalyst to the mixture. After maintaining reactor mass, solid product is isolated by adding N - Hexane & Ethyl Acetate. The obtained solid is dissolved in Di- Chloro Methane & reacted with Sodium meta Periodate to get the Stage – I. Stage – II
Stage – I is dissolved in the THF and reacted with Zinc Dust and Ethyl Bromo Di Fluoro Acetate in presence of Tri Methyl Chloro Silane. Product is extracted in Ethyl Acetate & washed with Sodium Chloride & Bi carbonate solution. Stage – III
Liquid residue of Stage- II product is dissolved in Acetonitrile, reacted with Trifluro Acetic Acid & water after removal of Acetonitrile Pyridine and 4-Di Methyl Amnino Pyridine is added. Obtained product is extracted in Ethyl Acetate, washed with Sodium Chloride & Sodium Bi Carbonate product is isolated by adding Di Chloro Methane & n - Hexane as Di Benzoyl Lactum dried in try.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 172 }
SPPL
Di – Benzoyl lactum Process Flow Diagram Stage – I
Stannous Chloride (0.005K) Ethyl Acetate (30L) N – Hexane (21.5L) Di- Methyl Sulfoxide (4.5L) Sod Meta per Iodate (2.8K) Di-Chloro Methane (20L) D- Manitol (2.5K) Water (10.00L) 2-2 Dimethoxy Propane (4.4L) Hyflow ( 0.15K) . Charcoal(0.05K) N-Haxane ( 18.75L) Ethly Acetate ( 26.25L) Di-Chloro Methane ( 17.5L) Vapour Loss ( 2.85K) Liq-Effluent to ETP (28.75L) Charcoal & Hyflow ( 0.2K) Stage – I ( 1.6K)
S S R
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 173 }
SPPL
STAGE-II ST- I (1.6K)
HCL (1.55L) TMCS (0.0075) Ethyl Acetate (18L) Soda Bicarbonate (0.265K) EBDFA (1.8K) THF (15.5L) Water ( 25L) Sod. Chloride (4.185K)
Liquid Effluent to ETP (36.56L) THF( 13.75L) Ethyl Acetate ( 15L)
Stage – II (2.6K)
S S R
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 174 }
SPPL
STAGE-III Stage –II ( 2.6K)
Pyridine (2.3L) Toluene (11L) 4 DMAP (0.3125K) Ethyl Acetate (23.75K) Benzoyl Chloride (3.15K) Water (10.00L) Trifuloro Acetic Acid (0.3125K) Di – Chloride Methane (7.25L) N- Hexane (10L) Acetonitrile (20L) NACL (0.1837) Charcoal (0.25K)
HCL (0.8L) Hyflow (0.25K)
Sod. Bi- Carb. (0.39K) Tolune ( 10L) Etyl Acetate ( 21.25L)
Liquid Effluent to ETP (29.30L) N-Haxane (8L) Acetonitrile (18L) Di-Choloro Metahan(5L) Stage – III ( Di Benzoyl Lactum ) (1K)
SSR
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 175 }
SPPL
PRODUCT : LIGNOCAIN HCL Brief Process
Lignocain Crude base is dissolved in Acetone water, Charcolised & to the clear SOP HCl is added to get Lignocain HCl.
Lignocain HCl Process Flow Diagram
Lignocain Base (0.93) Acetone (2.0) HCL (1.0) Charcoal & Hyflow (0.1) Acetone Recovery ( 1.85 ) Charcoal & Hyflow (0.1) To ETP (1) Residue to ( 0.08 ) Solid wastes Lignocain HCL ( Approx. 1.0Kg)
S S R
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 176 }
SPPL
ANNEXURE – 3
DETAILED SPECIFICATIONS OF INCINERATOR
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 177 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 178 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 179 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 180 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 181 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 182 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 183 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 184 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 185 }
SPPL
ANNEXURE – 4
GA DRAWING OF SCRUBBER
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 186 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 187 }
SPPL
ANNEXURE – 5
MEMBERSHIP CERTIFICATE OF TSDF SITE
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 188 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 189 }
SPPL
ANNEXURE – 6
NATIONAL AMBIENT AIR QUALITY STANDARDS
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 190 }
SPPL
NATIONAL AMBIENT AIR QUALITY STANDARDS ( NAAQS ) ( 2009 )
Sr. No.
Pollutant Time Weighted Average
Concentration In Ambient Air Industrial, Residential,
Rural & Other Area
Ecologically Sensitive
Area (Notified by
Central Govt.)
Methods of Measurement
1 Sulphur Dioxide (SO2), ug/m3
Annual *
24 hours **
50
80
20
80
• Improved West & Gaeke
• Ultraviolet fluorescence
2 Nitrogen Dioxide (NO2), ug/m3
Annual *
24 hours **
40
80
30
80
• Modified Jacab & Hochheiser (Na-Arsenite)
• Chemiluminescence 3 Particulate Matter (size
less than 10 um) or PM10, ug/m3
Annual *
24 hours **
60
100
60
100
• Gravimetric • TOEM • Beta attenuation
4 Particulate Matter (size less than 2.5 um) or PM2.5, ug/m3
Annual *
24 hours **
40
60
40
60
• Gravimetric • TOEM • Beta attenuation
5 Ozone(O3), ug/m3 8 hours **
1 hour **
100
180
100
180
• UV photometric • Chemiluminescence • Chemical method
6 Lead (Pb), ug/m3 Annual *
24 hours **
0.50
1.0
0.50
1.0
• AAS/ICP method after sampling on EPM 2000 or equivalent filter paper
• ED – XRF using Teflon filter
7 Carbon Monoxide (CO), ug/m3
8 hours *
1hour **
02
04
02
04
• Non-dispersive Infrared (NDIR) spectroscopy
8 Ammonia (NH3), ug/m3 Annual *
24 hours **
100
400
100
400
• Chemiluminescence • Indophenol blue method
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 191 }
SPPL
9 Benzene (C6H6), ug/m3 Annual * 05 05 • Gas Chromatography based continuous analyzer
• Adsorption & Desorption followed by GC analysis
10 Benzo(a) Pyrene(BaP) – Particulate phase only, ug/m3
Annual * 01 01 • Solvent Extraction followed by HPLC/GC analysis
11 Arsenic (As), ug/m3 Annual * 06 06 • AAS/ICP method after sampling on EPM 2000 or equivalent filter paper
12 Nickel (Ni), ug/m3 Annual * 20 20 • AAS/ICP method after sampling on EPM 2000 or equivalent filter paper
* Annual arithmetic mean of minimum 104 measurements in a year at a particular site taken twice a week 24 hourly at uniform intervals. ** 24 hourly or 08 hourly or 01 hourly monitored values, as applicable, shall be complied with 98 % of the time in a year. 2% of the time, they may exceed the limits but not on two consecutive days of monitoring. Note : Whenever and wherever monitoring results on two consecutive days of monitoring exceed the limits
specified above for the respective category, it shall be considered adequate reason to institute regular or continuous monitoring and further investigation.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 192 }
SPPL
ANNEXURE – 7
DRINKING WATER STANDARDS
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 193 }
SPPL
INDIAN STANDARDS FOR DRINKING WATER IS : 10500, 1991 Sr. CHARACTERISTICS REQUIREMENT UNDESIRABLE PERMISSIBLE No. (DESIRABLE) EFFECTS OUTSIDE LIMIT IN
THE DESIRABLE LIMIT ABSENCE OF
ALTERNATE
SOURCE 1) Colour, Hazen units 5 Above, consumer 25 acceptance decreases
2) Odour -- Unobjectionable --
3) Taste -- Agreeable --
4) Turbidity, NTU 5 Above, consumer 10 acceptance decreases
5) pH Value 6.5 to 8.5 Beyond this range, the No relaxation water will affect the mucous membrane and / or water supply system
6) Total Hardness, 300 Encrustation on water 600 mg / L as CaCO3 supply structure and adverse effects on domestic use
7) Iron, mg / L ( as Fe ) 0.3 Beyond this limit, taste / 1 appearance are affected. Has Hadverse effect on domestic uses and water supply structures structures & promotes iron bacteria
8) Chlorides, mg / L ( as Cl ) 250 Beyond this limit, taste, 1000 corrosion and palatability are affected
9) Residual Free 0.2 -- -- Chlorine, mg / L
10) Total Dissolved 500 Beyond this, palatability 2000 Solids, mg / L decreases and may cause gastrointestinal irritation
11) Calcium, mg / L ( as Ca ) 75 -- 200
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 194 }
SPPL
INDIAN STANDARDS FOR DRINKING WATER IS : 10500, 1991 (contd.)
Sr. CHARACTERISTICS REQUIREMENT UNDESIRABLE PERMISSIBLE No. (DESIRABLE) EFFECTS OUTSIDE LIMIT IN
THE DESIRABLE LIMIT ABSENCE OF ALTERNATE SOURCE 12) Copper, mg / L ( as Cu ) 0.05 A stringent taste, discoloration 1.5
of pipes, fitting and utensils will be caused beyond this
13) Manganese, mg/L (as Mn) 0.1 A stringent taste, discoloration 0.3 of pipes, fitting and utensils will be caused beyond this
14) Sulphates, mg / L as SO4 200 Beyond this causes 400 gastrointenstinal irritation when Magnesium or Sodium are present
15) Nitrates, mg / L as NO3 45 Beyond this, 100 methaemoglobinemia
16) Fluoride, mg / L (as F) 1 Fluoride may be kept as low 1.5 as possible. High Fluoride may cause Fluorosis
17) Phenolic Substances 0.001 Beyond this, it may cause 0.002 mg / L (as C6H5OH) objectionable taste and odour
18) Mercury, mg / L (as Hg) 0.01 Beyond this, the water becomes No relaxation toxic
19) Cadmium, mg / L (as Cd) 0.01 Beyond this, the water becomes No relaxation toxic
20) Selenium, mg / L (as Se) 0.01 Beyond this, the water becomes No relaxation toxic
21) Arsenic, mg / L (as As) 0.05 Beyond this, the water becomes No relaxation toxic
22) Cyanide, mg / L (as Cn) 0.05 Beyond this, the water becomes No relaxation toxic
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 195 }
SPPL
INDIAN STANDARDS FOR DRINKING WATER IS : 10500, 1991 (contd.)
Sr. CHARACTERISTICS REQUIREMENT UNDESIRABLE PERMISSIBLE No. (DESIRABLE) EFFECTS OUTSIDE LIMIT IN
THE DESIRABLE LIMIT ABSENCE OF
ALTERNATE
SOURCE 23) Lead, mg / L (as Pb) 0.05 Beyond this, the water becomes No relaxation
toxic
24) Zinc, mg / L (as Zn) 5 Beyond this limit, it can cause 15 stringent taste and an opalescence in water
25) Anionic Detergents 0.2 Beyond this limit, undesirable 1 mg / L (as MBAS) taste and odour after chlorination takes place
26) Chromium, mg / L as Cr+6 0.01 May be carcinogenic above this limit 0.05
27) Polynuclear Aromatic May be carcinogenic Hydrocarbons, mg / L (as PAH)
28) Mineral Oil, mg / L 0.01 Beyond this limit, undesirable 0.03 taste and odour after chlorination takes place
29) Pesticides, mg / L Absent Toxic 0.001
30) Radioactive Materials, a) Alpha emitters, Bq / L 0.1 b) Beta emitters, pci / L 1
31) Alkalinity, mg / L 200 Beyond this limit, taste 600 (as CaCO3) becomes unpleasant
32) Aluminum, mg / L (as Al) 0.03 Cumulative effect is reported 0.2 to cause dementia
33) Boron, mg / L (as B) 1 5
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 196 }
SPPL
ANNEXURE – 8
EFFLUENT DISPOSAL STANDARDS ( IS )
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 197 }
SPPL
INDIAN STANDARDS FOR INDUSTRIAL AND SEWAGE EFFLUENT DISCHARGE IS : 2490 - 1982
Sr. CHARACTERISTICS INTO INLAND ON LAND INTO INTO PUBLIC No. SURFACE FOR MARINE SEWERS
WATER IRRIGATION COASTAL AREA 1) Colour / Odour -- -- -- --
2) Suspended Solids, mg / L 100 200 100 (for Process 600 Waste)
3) Particle Size Suspended Solids Shall pass 850 µ -- Floatable Solids, -- (MPN / 100 ml), Max. IS Sieve Max. 3 mm Settleable Solids, Max 850 µ
4) Total Dissolved Solids (Inorganic) 2100 2100 -- 2100 (mg / L)
5) pH Value 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0
6) Temeprature, o C Shall not exceed 40 in any -- 45 at the point of -- section of the stream within discharge 15 m. downstream from the effluent outlet
7) Oil & Grease, mg /L 10 (Max.) 10 (Max.) 10 (Max.) 20 (Max.)
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 198 }
SPPL
8) Total Residual Chlorine, mg / L 1.0 (Max.) -- 1.0 (Max.) -- 9) Ammonical Nitrogen (as N), mg / L 50 (Max.) -- 50 (Max.) 50 (Max.)
10) Total Kjeldahl Nitrogen (as N), mg / L 100 (Max.) -- 100 (Max.) --
11) Free Ammonia (as NH3), mg / L 5 (Max.) -- 5 (Max.) --
12) Biochemical Oxygen Demand, mg / L 30 100 100 350 5 days at 20 o C
13) Chemical Oxygen Demand, mg / L 250 (Max.) -- 250 (Max.)
14) Arsenic (as As), mg / L 0.2 (Max.) 0.2 (Max.) 0.2 (Max.) 0.2 (Max.)
15) Mercury (as Hg), mg / L 0.01 (Max.) -- 0.01 (Max.) 0.01 (Max.)
16) Lead (as Pb), mg / L 0.1 (Max.) -- 1.0 (Max.) 1.0 (Max.)
17) Cadmium (as Cd), mg / L 2.0 (Max.) -- 2.0 (Max.) 1.0 (Max.)
18) Hexavalent Chromium (as Cr+6), mg / L 0.1 (Max.) -- 1.0 (Max.) 2.0 (Max.)
19) Total Chromium (as Cr), mg / L 2.0 (Max.) -- 2.0 (Max.) 2.0 (Max.)
20) Copper (as Cu), mg / L 3.0 (Max.) -- 3.0 (Max.) 3.0 (Max.)
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 199 }
SPPL
21) Zinc (as Zn), mg / L 5.0 (Max.) -- 15 (Max.) 15 (Max.) 22) Selenium (as Se), mg / L 0.05 (Max.) -- 0.05 (Max.) 0.05 (Max.)
23) Nickel (as Ni), mg / L 3.0 (Max.) 5.0 (Max.) 3.0 (Max.)
24) Boron (as B), mg / L 2.0 (Max.) 2.0 (Max.) -- 2.0 (Max.)
25) Percent Sodium -- 60 (Max.) 60 (Max.) --
26) Residual Sodium Carbonate, mg / L -- 50 (Max.) -- --
27) Cyanide (as CN), mg / L 0.2 (Max.) 0.2 (Max.) 0.2 (Max.) 0.2 (Max.)
28) Chlorides (as Cl), mg / L 1000 (max.) 600 (max.) -- 1000 (Max.)
29) Fluorides (as F), mg / L 2.0 (Max.) -- 15 (Max.) 15 (Max.)
30) Dissolved Phosphates (as P), mg / L 5.0 (Max.) -- -- --
31) Sulphates (as SO4), mg / L 1000 (Max.) 1000 (Max.) -- 1000 (Max.)
32) Sulphides (as S), mg / L 2.0 (Max.) -- 5.0 (Max.) --
33) Phenolic Compounds (as C6H5OH), 1.0 (Max.) -- 5.0 (Max.) 6.0 (Max.) mg / L
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 200 }
SPPL
34) Radioactive Materials a) Alpha Emitters, µc / ml 10 - 7 (Max.) 10 - 8 (Max.) 10 - 7 (Max.) 10 - 7 (Max.) b) Beta Emitters, µc / ml 10 - 6 (Max.) 10 - 7 (Max.) 10 - 6 (Max.) 10 - 6 (Max.)
35) Manganese (as Mn), mg / L 2.0 (Max.) 2.0 (Max.) -- 2.0 (Max.)
36) Iron (as Fe), mg / L 3.0 (Max.) 3.0 (Max.) -- 3.0 (Max.)
37) Vanadium (as V), mg / L 0.2 (Max.) -- 0.2 (Max.) 0.2 (Max.)
38) Nitrate Nitrogen, mg / L 18 20 -- 0.2
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 201 }
SPPL
ANNEXURE – 9
AMBIENT NOISE STANDARDS
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 202 }
SPPL
AMBIENT NOISE STANDARDS AS PER THE NOISE POLLUTION RULES, 2000
CATEGORY OF AREA Leq dB (A), Day Time Leq dB (A), Night Time (06:00 to 21:00 hours) (21:00 to 06:00 hours) Industrial Area 75 70 Commercial Area 65 55 Residential Area 55 45 Silence Zone 50 40
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 203 }
SPPL
ANNEXURE – 10
OSHA NORMS FOR NOISE
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 204 }
SPPL
DAMAGE RISK CRITERIA FOR HEARING LOSS
OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA)
MAXIMUM ALLOWABLE DURATION, NOISE LVEL, (dBA) HOURS / DAY (SLOW RESPONSE)
8 90 6 92 4 95 3 97 2 100
1.5 102 1 105
0.5 110 0.25 or less 115
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 205 }
SPPL
ANNEXURE – 11
MAJOR INDUSTRIES IN STUDY AREA
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 206 }
SPPL
MAJOR INDUSTRIES IN THE STUDY AREA
1. ETC Agro Food Processing Pvt. Ltd., Vil. : Andhaj
2. Maxmech Equipments Pvt. Ltd., Vil. : Varsola
3. Amul Satellite Dairy – Vil. : Jibhaipura
In addition to the above stated major industries, the area houses few smaller units i.e. saw mills and other miscellaneous type of industries.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 207 }
SPPL
ANNEXURE – 12
RAIN WATER RECHARGE SCHEME
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 208 }
SPPL
DETAILS OF TYPICAL RAIN WATER RECHRGE SCHEME
Net increase in water requirement of the project is estimated to be approximately 4.0 KL per day and is proposed to be met through existing bore – well within the premises. Hence, to compensate for this withdrawal, a rain water harvesting and recharging scheme is proposed. The necessity to harness rainwater and to recharge the same into the ground water aquifer has been recognized. Hence, it is decided to harvest rain water from roofs and surface run – off from internal roads and open vacant space within the premises and recharge it. Rain water collected from roof tops and surface run – off will be suitably collected and conveyed to a central point where a suitable recharge structure will be constructed. Generally, it is economical to recharge directly existing open wells or tube wells but as there are no existing open wells or tube wells in the project site, new recharge pits are being proposed. The recharge structure should be such that its filter media can be easily taken out and washed so that clays deposited during filtration are removed to regain the original infiltration rate and reinstalled conveniently without much expenditure. Keeping this in view, recharge pits and recharge trenches are being proposed for this project. Initially, 1 no. of recharge pit cum filtration tank of size 2 mt. x 2 mt. x 3 mt. deep is proposed to be constructed within the premises with a tube well in the centre of the filtration pit. The tube well will have a slotted 200 mm dia. pipe which will extend upto the unsaturated zone of water. Recharging of ground water through these pit will be monitored and based on data of recharge, if required, more no. of similar recharge pits will be constructed within the premises. Roof top rain water from plant building of the project will be collected through 100 mm PVC drain pipes and will be taken to the recharge pit through PVC / MS pipe of suitable size. The recharge pit cum filtration tank will be provided with 0.90 mt. thick layer of pebbles (10 mm to 30 mm in size) at the bottom followed by 0.90 mt. thick layer of gravel (5 mm to 10 mm in size) followed by 0.90 mt. thick coarse sand (2 mm to 4.75 mm in size). At the top of the tank, a 0.30 mt. thick layer of pebbles or a layer of boulders (more than 30 mm in size) will be laid so that drain water does not disturb the coarse sand due to turbulence. The top of the tank will be slightly above the land surface so that silty surface water does not enter in the filtration tank. This tank will be lined with brick mortar or stone mortar (with cemented wall) but bottom portion will be exposed in sand or boulders.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 209 }
SPPL
Any surplus water from the filtration tank will be taken as overflow to a recharge trench to be constructed along the side of the recharge tank. Both the width and depth of the trench will be kept as 1.0 mt. The trench will be unlined, filled at the bottom with 30 cm. thick layer of pebbles, 30 cm. thick layer of gravel, 30 cm. thick layer of coarse sand and 10 cm. thick layer of pebbles or one layer of boulders. An outlet of 100 mm. G.I pipe will be provided from the top of the filtration tank to the recharge trench in such a way that water gets filled all along the length of the trench. The water in the trench will gradually percolate and join the water table in due course of time. The length of trench will be suitably decided. Such an arrangement will maximize rain water recharge potential. Considering roof area of plant to be approximately 225 sq. mtrs. and assuming average annual rain-fall as 850 mm and 0.85 as runoff co-efficient for cemented roofs, Available roof water for recharge = 225 x 0.85 x 0.85 = 162 KL per year or say = 160 KL per year. Considering approximate road area and other open area of plant to be 1650 sq. mtrs. and assuming average annual rain-fall as 850 mm and 0.75 as runoff co-efficient for road and other open area, Available water for recharge = 1650 x 0.75 x 0.85 = 1052 KL per year or say = 1050 KL per year. Thus, total quantity of water that can be recharged per year = 160 + 1050 = 1210 KL per year This figure meets the total per year additional ground water withdrawal of 1200 KL (4.0 KL per day x 300 no. of working days per year). Typical cross – section of recharge pit is presented in figure below.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 210 }
SPPL
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 211 }
SPPL
ANNEXURE – 13
LIST OF PERSONAL PROTECTIVE EQUIPMENTS
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 212 }
SPPL
LIST OF PERSONAL PROTECTIVE EQUIPMENTS TO BE PROVIDED IN PLANT
Protection for Equipment Protection Against Indian Standards
Head Helmet
Fall of objects/hitting against objects during construction, maintenance, etc.
IS 2925 : 1984
Eye Leather mask goggles Foreign bodies entering the eyes and smoke. IS 5983 : 1980
Spectacle type goggles with plain shatter proof lens
Foreign bodies entering the eyes and reflected arc rays.
IS 1179 : 1967
Panorama goggles with green plastic vision
Reflected arc rays during arc welding job. IS 1179 : 1967
Ear Ear plugs or muffs High noise level. IS 8520 : 1977
Nose Dust respirators Fine dust particles. IS 9473 : 1980
Light fume mask
Acid fumes, vapors and gases (2.0%). IS 8522 : 1977
Canister gas mask Acid fumes, vapors and gases (2.0%). IS 8523 : 1977
Face Plastic face shield Liquid chemicals, dust particles. IS 8940 : 1978
Welding helmet and shield Welding fumes, sparks and UV rays. IS 8521 : 1977
Body Leather apron Falling of hot chips, slogs, etc. IS 818 : 1968
PVC apron Splashing of chemicals. IS 4501 : 1981
Safety belt Falling of persons from height. IS 3521 : 1983
Hand Acid and Alkali proof rubber gloves
Burns due to chemical handling. IS 2573 : 1986
Electrical resistance gloves Electric shock. IS 4770 : 1968
Canvas gloves Contact with oil, grease, etc. IS 6994 : 1973
Leg Leather safety boots
Striking by objects, fall of objects and stepping on sharp or hot objects.
IS 1989
Ankle boot for general purposes stepping on hot or sharp objects, striking by stationary or moving objects.
IS 583 : 1981
Gum boots Liquid splashing in submerged area and chemically hazardous area.
IS 5557 : 1969
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 213 }
SPPL
ANNEXURE – 14
COMPLIANCE OF CREP GUIDELINES
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 214 }
SPPL
PHARMACEUTICALS
Sr. No. Action Point
Compliance
01. Segregation of waste stream Waste streams should be segregated into high COD waste, toxic waste, low COD waste, inorganic waste etc. for the purpose of providing appropriate treatment
Concentrated process stream, scrub liquor effluent, softening plant regeneration water, cooling tower blow – down etc. will be incinerated in in – house incinerator. Solvents will be recovered in solvent recovery unit and recycled back to process. Distillation residue will be segregated and sent to BEIL for incineration or in in – house incinerator.
02. Detoxification and treatment of high COD High COD streams should be detoxified and treated in ETP or thermally destroyed in incinerator.
Concentrated process effluent stream and scrubber effluent will be incinerated in in – house incinerator. Similarly, distillation residue will be sent to BEIL for incineration or in in – house incinerator.
03. Management of solid waste Proper facilities should be provided for handling and storage of hazardous waste. For final disposal of hazardous waste, recycling and reuse should be given priority, either within the premises or outside with proper manifest system. In case of incinerable waste, properly designed incinerator should be installed within the premises or outside as a common facility. The non-incinerable hazardous waste should be disposed of in properly designed secured landfill either within the industry’s premises or in a common facility.
Separate solid waste storage area having impervious bottom, pucca roof and leachate collection system has been provided. Leachate, if any, will be taken to ETP for treatment and disposal. All hazardous wastes will be separately stored at this site in appropriate container. ETP sludge and spent carbon / hyflow etc. will be disposed off into TSDF of NEPL. Distillation residue will be sent to common incineration facility of BEIL or in in – house incinerator. Used oil will be given to CPCB registered re-processor of oil and discarded containers will be given to registered vendor after decontamination. Unit has already taken membership of TSDF of NEPL.
04. Minimum scale of production to afford cost of pollution control For new industries which are not connected with CETP & TSDF and which do not have the economics to install treatment facilities may not be considered for granting consent to establishment. Industry association shall submit proposal to SPCB / CPCB
Unit already has an in-house ETP cum incinerator for treatment of all effluent streams. For disposal of hazardous wastes it has become member of TSDF of NEPL.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 215 }
SPPL
05. Long term strategies for reduction in waste Consent for establishment and consent for operation under Water Act will be based on pollution load and concentration of pollutants. Each industry will submit pollution load, concentration of final discharge alongwith water balance to SPCB/CPCB for formulation of strategy
Necessary details will be provided to GPCB at appropriate stage of project implementation. Unit will strive to reduce pollution load through optimum utilization of resources like raw material etc.
06. Control of air pollution Industry will take up on priority, the control of hazardous air pollutants (such as benzene, carbon tetrachloride, 1-4 dioxane, methanol, toluene, methyl chloride etc.) and odorous compounds (mercapatan & hydrogen sulphide)
Minimum inventory of raw materials will be kept. Handling / transfer of Solvents will be by metering pumps to minimize loss to atmosphere. Cooling and chilled water / brine will be passed through condensers installed on reactors to control fugitive emission of VOC. Received solvents will be sent back to process and condenser vents will be attached to scrubber to further minimize chance of solvent vapours being released into the atmosphere.
07. Self Regulation by Industry though regular monitoring and environmental auditing Industries on their own will carry out monitoring of environmental parameters, audit it in regular interval and submit the same to SPCB. Comment of BDMA - There will be a policy for accreditating the auditors and the policy guidelines may be issued by the MoEF.
All applicable environmental parameters will be regularly monitored as per the environmental monitoring plan devised by the unit. Environmental Statement (in Form-V) will be regularly submitted to GPCB.
08. Oranisational restructuring and accreditation of Environmental Manager of Industry (a) Environment management cell will be created for each industry reporting to CEP directly. (b) There should be a certification system for the environmental managers at individual level and common facility level. BDMA may evolve the programme alongwith SPCB/CPCB
Company will set-up an Environment cell consisting of well-qualified and experienced professionals from the field of safety and environment. Company will endeavour to obtain ISO : 14001 certification.
09. Optimising the inventory of hazardous chemicals The information shall be submitted to SPCB regularly alongwith rational
All rules and regulations of Factory Inspectorate will be complied with. On-site emergency plan will be prepared based on risk assessment study and strictly implemented. All details will be submitted to all concerned authorities as per MSIHC Rules.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 216 }
SPPL
ANNEXURE – 15
BRIEF PROFILE OF CONSULTANT ENGAGED FOR REIA STUDY
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 217 }
SPPL
PROFILE OF CONSULTANTS ENGAGED FOR EIA STUDY
CONSULTING FIRM : AKSHAR CONSULTANTS ADDRESS : 813, SAKAR – 5, NEAR MITHAKHALI RAILWAY CROSSING, OFF ASHRAM ROAD, AHMEDABAD 380 009, GUJARAT. TEL. NO. : 079 – 26583525 FAX NO. : 079 – 26583525 E MAIL : [email protected] PROMOTER’S NAME : MR. DARSHAN PAREKH. B. E. ( ENV. ENG. ) PROMOTER’S EXPERIENCE :
More than 20 (Twenty) years of experience in the field of Environment Management System ( EMS ) and pollution control of various industries like chemical, dyes and dyes - intermediates, textiles, pharmaceuticals, rolling mills, cement etc. i. e. design, commissioning and operation of small to very large ETPs, carrying out of EIA studies, air pollution control systems, treatability studies, environmental audits etc.
ADDITIONAL INFORMATION : Organisation has in-house laboratory facility equipped with all necessary instruments / equipments / glassware etc. required for testing of pollution parameters ( water / effluent / gaseous emission / solid wastes / soil / noise etc. ) and to carry-out EIA studies. Adequate human resources having requisite qualification and experience is retained and forms part of a young and dedicated team of professionals.
REGISTRATIONS : Akshar Consultants is registered with GPCB, Gandhinagar as “Recognised Schedule–II Environmental Auditor “ and has also submitted its’ application to NABET / QCI, New Delhi for accreditation as EIA consultant organization.
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 218 }
SPPL
LIST OF PERSONS INVOLVED IN THIS ASSIGNMENT
SR. NO.
NAME DESIGNATION QUALIFICATION
1 Shri Darshan Parekh Proprietor B.E. ( Env. )
2 Shri Gopal Deware Chemical Engineer B.E. ( Chem. )
3 Shri Virpalsinh Chavda Chemist B.Sc. ( Chemistry )
4 Ms. Ashita Bhavsar Microbiologist B.Sc. ( Microbiology )
5 Ms. Shefali Khatri Sr. Computer Analyst B. Com., DCT
6 Dr. Manoj Eledath Technical Associate M.Sc., Ph.D.
7 Shri Prakash Vaghela Technical Associate B.E. ( Env. )
8 Shri Sundeep Shah Technical Associate B.E. ( Env. )
9 Shri Chandrashekhar Vaidya
Technical Associate B.E. (Electronics), M.E. (Computer Appl.)
10 Shri Kaushik Pandya Field Supervisor H.S.C.E.
11 Skilled and semi – skilled field staff
--- ---
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 219 }
SPPL
ANNEXURE – 16
UNDERTAKING BY PROJECT PRAPONENT
Akshar Consultants
REIA OF SWANA PHARMACEUTICALS PVT. LTD., VIL. : VARSOLA, DIST.:KHEDA, GUJARAT. { 220 }
SPPL
Top Related