Changing Brushes G2K Style Motors
The FIRST step is to ...
Unplug the motor!
Removing cooling fan cover
Remove/loosen Brush clamp screws.
Removing old Brush Clip mech.
Be sure positioning tab of new brush mech...
….is placed in slot on bracket.
Reassemble Brush Clamp
Clamp terminal connects with field terminal
Install clamp screws and seat the brushes.
Remember….
Don’t over tighten thescrews!!!
Ideal Industries – Cat No. 23-001H Brush Seater and Commutator Cleaner
www.idealindustries.com