• To use the products given in this catalog properly, always read the "manuals" before starting to use them.
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
For safe useThis catalog explains the typical features and functions of the Q series PLCs and does not provide restrictions and other information on usage and module combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the Q series data book. When using the products, always read the user's manuals of the products.Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
Precautions for Choosing the Products
When exported from Japan, this manual does not require application to theMinistry of International Trade and Industry for service transaction permission.
L(NA)08039E-B 0703(MDOC)New publication, effective Mar. 2007
Specifications subject to change without notice.
Open field NetworkCC-Link and CC-Link/LT Compatible product databook O
pen field Netw
ork CC
-Link and CC
-Link/LT C
ompatible product databook
Mar
2007
Strategic Network,CC-Link &CC-Link/LT.S t r o n g M a n u f a c t u r e r s
S t a y O n e S t e p A h e a d o f O t h e r s w i t h
C C - L i n k & C C - L i n k / L T
Let's Start Powerful Factory Automation.Let's Connect with Powerful Networks.
Compatible Products
Concept 3 to 20
I N D E X
<CC-Link>
System Configuration Example
Product Information
<CC-Link/LT>
System Configuration
Example
Product Information
<Other>
Embedded Modules
Other/Software
Technical Information
Support
Product List
22
23
25 to 134
136
137 to 140
141 to 188
190
191 to 198
199 to 214
215 to 224
225 to 228
231 to 234
MELSECNET/H
Ethernet
QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QX42-S1QY42P
PULL
MODERUNERR
USERBAT
BOOT
RS-232
QJ71LP21-25
QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QX42-S1QY42P
PULL
MODERUNERR
USERBAT
BOOT
RS-232
QJ71LP21-25QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QX42-S1QY42P
PULL
MODERUNERR
USERBAT
BOOT
RS-232
QJ71LP21-25
QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QJ71LP21-25QY42P
PULL
MODERUNERR
USERBAT
BOOT
RS-232
QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QX42-S1QY42P
PULL
MODERUNERR
USERBAT
BOOT
RS-232
Max. 2.5 Mbps
Max. 25 Mbps
Max. 10 Mbps
Max. 2.5 Mbps
100/10 Mbps
Q12HCPU
USB
PULL
RS-232
QX42-S1
QY42P
PULL
POWERQ25HCPU
USB
QJ71LP21-25QY42P
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
RS-232
QX42-S1
SERVO SYSTEM CONTROLLER NETWORK
We provide customers all over the world total support for FA networks, includingCC-Link and CC-Link/LT, through our "Mitsubishi Global FA Center"s for overseasproduction support.
Full-scale support system that helps customers make reliable, satisfied use of networks
We provide total support in constructing seamless networks in all scenes, from offices to production sites, under a consistent
design philosophy.
With flexible approaches backed by "Ethernet," "MELSECNET/H" and "CC-Link", a SEMI-certified, world standard field
network originated in Japan, and "CC-Link/LT", a sensor level network adhering to the design concept of CC-Link,
we propose a network-based FA environment, fit for your needs.
Seamless integration ofthe network over all layers
Ethernet
MELSECNET/H
CC-Link
CC-Link/LT
[Between factory departments]Enterprise level network
The top layer of the Network hierarchy. It contributes to higher production efficiency through the collection and management of various production information around a plant.
[Within factory]Control level network
MELSECNET/H allows communication between controllers on a line. Its high-speed communication and large-capacity link device ensures real-time transmission of data relating directly to the operation and performance of machines and equipment among controllers.
Opening up the Future of FA Networks and Focusing on what's
3 4
High-speed communication at a maximum baudrate of 10 MbpsRemote input/output (RX, RY): 8,192 points eachRemote register (RWw) : 2,048 words (RWr) : 2,048 words
Integration with 3rd party manufacture products
CC-Link is a high-speed field network capable of controlling the system and handling information at the same time, and offers high-speed, reliable input/output response and highly flexible expandability. This distinguished performance the network earned SEMI certification. A Japanese-origin, world standard open field network, CC-Link holds a large market share and has been winning the confidence of customers.
Easy installation using dedicated connectorsThe adoption of point number modes (foupoints, eight points, 16 points) permits effectiveuse of I/O points.The maximum number of link points is 1,024 in16-point mode.
CC-Link/LT is a sensor level network designed so that all production sites are free from complicated wiring or incorrect wiring. It inherits openness, high speed, and noise resistance from the CC-Link family and at the same time ensures reduced wiring because of its simple setting and easy installation.
CL1PAD1 CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
CL1PAD1 CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25
PULL
MODERUNERR
USERBAT
BOOT
Q64P
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
[Within line]Device level network
[Within panel and devices]Sensor level network
Max. 2.5 Mbps
CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
(when CC-Link Ver. 2.0 is used)
FX3UC-32MT-LT
<Between factory departments>Enterprise level network
<Within factory>Control level network
<Within line>Device level network
<Within panel and devices>Sensor level network
Ethernet
MELSECNET/H
You can set parameters on CC-Link using only the MELSEC total programming tool "GX Developer." You can significantly reduce program size and efficiently set parameters.
For improved setup efficiency [Simple parameter setup]
For non-stop operation [RAS functions]
More than 500 type of products are supplieds from more than 500 companies worldwide.
A diverse range of products from partner manufacturers[Multi-vendor system]
Large-scale applications from Factory Automation through building management[Max. cable length of 13.2 km]
CC-Link is a high-performance network that utilizes high-speed communications (10 Mbps -top level in the industry-), in order to allow transmission of bit data and word data at high-speed and maximum capacity.
For achieving complex control, high-mix low-volume production [High-speed, high-capacity transmission]
Overall cable distance of CC-Link
5 Mbps
2.5 Mbps
625 kbps
156 kbps
100
400
900
160
4,300
4,480
4,4005,200
6,7009,900
7,60013,200
1,760
1,200
1,100
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 (m)
Link
sca
n tim
e (m
s)
0 20 40 600
1
2
3
4
5
6
Number of units [units]
CC-Link Link Scan Time (at communication speed of 10 Mbps)
I/O control
Dedicated flat cable, VCTF (Vinyl Cabtire Code),
dedicated flexible cable
RXRY: 1024 points each
CC-link guarantees the fixed cyclic transmission time and the cyclic transmission time is not affected by irregular message transmission. It is therefore possible to achieve highly stable control.
For improved network reliability[Consistent network communication time]
CC-link realizes simple and cost-effective network, and it is designed to relieve production lines from complicated wiring.
For a simple and cost effective network[Reduced-wiring network]
CC-Link equips full RAS functionality by functions like Standby Master, Automatic Return, Slave Station Isolation and Diagnostics/Link Status Confirmation.
The total distance covered by the CC-Link network can be increased up to 1.2km (at 156 kbps). Additionally, the transmission distance can be further extendedthrough the use of T-branch repeater modules.Optical repeaters can also be used so that CC-Link deal with various large-scale facilities.
Max. 2.5 Mbps Max. 2.5 Mbps
Max. 10 Mbps
Max. 2.5 Mbps
QX42-S1
CL1PAD1CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
CL1PAD1CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
FX3UC-32MT-LT
Controlmethods
I/O control+
intelligent distribution
Cable
Maximumnumber
oflink points
I/O ModuleLine-up
Max. cabledistance
Parametersetup
Number oflink pointsper station
Networktopology
GX Developer
Dedicated fixed cable,dedicated flexible cable,
built-in power cable
RXRY: 8192 points each, RWr: 2048 words,
RWw: 2048 words (Ver2.0)
Screw terminal block, spring terminal block, e-CON, Push-in connector,
waterproof connector, 40-pin connector
1200 m (at 156 kbps)Extendable up to 13.2 km
when repeater is used
<Ver1.0> RXRY: 32 points each,RWr: 4 words, RWw: 4 words
<Ver2.0> RXRY: 128 points each,RWr: 32 words, RWw: 32 words
Bus topologyT-branch topology
Star topology
Not required
Max, 16 points(in 16-point mode)
T-branch topology
CC-Link CC-Link/LT
* RAS: Reliability, Availability, Serviceability Remote I/O station only
Remote device station only (when all stations 1 station is occupied)
Local node/intelligent device station only (when all stations 1 station is occupied)
10 Mbps
When repeaters (T-branch) are used
When repeater are not used
When optical repeaters (GI cables) are used
Screw terminal block,spring terminal block,
e-CON, MIL connector, cable connector
Trunk: 500 m Branch: 200 m (at 156 kbps)
CON
CB
A
D
401
202
104
81
42B R
ATEST
ATION
NO. L ERR.
L RUNPW
6543217
0
EDCBA9F
8
ON
AJ65VBTS3-16D
COM1-
NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF
COM1-
COM1+
COM1+
Q172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64P
AJ65SBT-CLB
40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1
PW L RUN L ERR.
STATION NO. B RATE NOS TST MODE B RATE NC
ON
CC-Link
CC-Link/LT
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8
CC-Link
L RUN L ERR. L ERR.
CC-Link/LTCC-Link
CC-Link/LT
Max. 10 Mbps
CC-Link - Proceeding toward a World Standard Network
5 6
CC-Link/LT - in pursuit of benefits through wire saving.
When 64 stations are connected, link scan time is a maximum of 1.2 ms(at 2.5Mbps), achieving excellent fast response performance.
For high-speed control [fast response]
For rapid startup of systems [easy installation]
Troublesome network parameter setting is unnecessary.The communication speed setting is required for the master module only.
For Easy usage [No need of parameter settings]
Improving reliability [prevention of miswiring]
The adoption of the point mode (4, 8, 16 points) enables I/O assignment that makes full utilization of the available number of points.
For Efficient use of I/O points [No wasting surplus I/O points]
CC-Link/LT also inherits the feature of CC-Link, complies withEMC directives for noise-resistance.
For High noise-resistance [Complying with EMC Directives]
Cable specific to application requirements[extensive lineup of cables]
CC-Link/LT Link Scan Time (at communication speed of 2.5 Mbps)
Link
sca
n tim
e (m
s)
0 20 40 600
0.5
1.0
1.5
2.0
2.5
Numberof stations
Using dedicated connectors and cables can reduce wiring works.Communication connectors are a male/female integrated type and available for all trunk and branch lines.
Dedicated flat cable, VCTF cable and Dedicated flexible cable.
Dedicated flat cable
VCTF cable Dedicated flexible cable
Orange indicatesNG (No Good).
Oh!! Flexible!!
"Snap!"
16-point mode
8-point mode
4-point modeMax. 2.5 Mbps
Max. 10 Mbps
Max. 2.5 Mbps
QX42-S1
CL1PAD1CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
CL1PAD1CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QX42-S1
QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
Q64P
AJ65SBT-CLB
40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1
PW L RUN L ERR.
STATION NO. B RATE NOS TST MODE B RATE NC
ON
CC-Link
CC-Link/LT
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8
CC-Link
L RUN L ERR. L ERR.
CC-Link/LTCC-Link
CC-Link/LT
CL2X8-D1C3V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
Max. 2.5 Mbps
PW
L RUN
L ERR.
0123456789ABCDEF
CL2X16-D1M1V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
CL2Y8-TP1B2
Y0Y1Y2Y3
Y4Y5Y6Y7
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO.0.5 ms1.5 ms
ON
OUT
0 1 2 3 4 5 6 7
CL1X2-D1D3S
PWL RUN0
STATION NO.
4020108 4 2 1
HLD
COMM.
124G
X0Y0+24 V
IN OUT
Max. 2.5 Mbps
CL2Y8-TP1B2
Y0Y1Y2Y3
Y4Y5Y6Y7
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO.0.5 ms1.5 ms
ON
OUT
0 1 2 3 4 5 6 7
CL1X2-D1D3S
PWL RUN0
STATION NO.
4020108 4 2 1
HLD
COMM.
124G
X0Y0+24 V
IN OUT
Max. 2.5 Mbps
PW
L RUN
L ERR.
0123456789ABCDEF
CL2X16-D1M1V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
CL2Y8-TP1B2
Y0Y1Y2Y3
Y4Y5Y6Y7
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO.0.5 ms1.5 ms
ON
OUT
0 1 2 3 4 5 6 7
CL1X2-D1D3S
PWL RUN0
STATION NO.
4020108 4 2 1
HLD
COMM.
124G
X0Y0+24 V
IN OUT
FX3UC-32MT-LT
Max. 2.5 Mbps
CL2Y8-TP1B2
CL2X16-D1M1V
CL1X2-D1D3S
FX3UC-32MT-LT
I/O control
Dedicated flat cable, VCTF (Vinyl Cabtire Code),
dedicated flexible cable
RXRY: 1024 points each
Controlmethods
I/O control+
intelligent distribution
Cable
Maximumnumber
oflink points
I/O ModuleLine-up
Max. cabledistance
Parametersetup
Number oflink pointsper station
Networktopology
GX Developer
Dedicated fixed cable,dedicated flexible cable,
dedicated built-in power supply
RXRY: 8192 points each, RWr: 2048 words,
RWw: 2048 words (Ver2.0)
Screw terminal block, spring terminal block, e-CON, Push-in connector,
waterproof connector, 40-pin connector
1200 m (at 156 kbps)Extendable up to 13.2 km
when repeater is used
<Ver1.0> RXRY: 32 points each,RWr: 4 words, RWw: 4 words
<Ver2.0> RXRY: 128 points each,RWr: 32 words, RWw: 32 words
Bus topologyT-branch topology
Star topology
Not required
Max, 16 points(in 16-point mode)
T-branch topology
CC-Link CC-Link/LT
Screw terminal block,spring terminal block,
e-CON, MIL connector, cable connector
Trunk: 500 m Branch: 200 m (at 156 kbps)
Dedicated cable shape is designed to prevent miswiring. The orange wire is visible when inserted the wrong way.
7 8
For hose in design, production and maintenance
Engineeringsection
Productionsection
Maintenancesection
Each person in charge of engineering,
production and maintenance has his/her own
challenge.
CC-Link and CC-Link/LT responds to each
challenge with a solution.
CC-Link is an establishined open field network
originatied from Japan.
Fully inheriting the CC-Link concept,
CC-Link/LT is specifically designed
as a sensor level network.
"I want this."
"I need this."
CC-Link & CC/Link/LT provides a function
for each challenge on the network.
CC-Link & CC-Link/LT
provide solutions
for each challenge in the field.
"I want to arrange devices as I desire."
CC-Link
"I need assembly/ disassembly to be easy."
CC-Link
"I want to prevent trouble from foreign substances"
CC-Link
"I want to save wiring time and cost."
CC-Link
CC-Link
CC-Link/LT
CC-Link/LT
"I need network testing for preventive maintenance."
CC-Link CC-Link/LT
"I want to do network maintenance from sites away from the PLC master."
CC-Link
"I need high noise resistance."
CC-Link CC-Link/LT
"I don't want to stop my system."
CC-Link
"I need easy troubleshooting."
CC-Link CC-Link/LT
Preventing troubleMore functions...
More simple...
More secure...
When trouble occurs...(troubleshooting)
"I need complex control features."
CC-Link
"I want to connect lots of analog devices."
CC-Link
"I want a distributed control system."
CC-Link
"I want a flexible production system."
CC-Link
At assembly...
At testing/operation...
"I want to use remote I/O."
"I need an easy network."
CC-Link
"I want to connect between lines.""I want a network for building management."
CC-Link
"I need high-speed sensor inputs."
"I want to connect lots of devices."
CC-Link
"I want to connect HMIs and 'ANDONs.' "
CC-Link
"I need widely used cables."
"I need high noise resistance."
CC-Link
CC-Link
CC-Link
"I need various devices on a singlenetwork."
CC-Link/LT
"I want to export our facilities and machinery overseas."
CC-Link/LT
CC-Link/LT
CC-Link
"I want to connect drives and servos."
(P11, P12) (P13, P14) (P15, P16)
The solutions provided by CC-Link & CC-Link/LT begin from here.
"I need quick check-up."
CC-Link/LT
109
High-speed/High-capacity data transmission
CC-Link is a high speed field network that can handle both controland information together.
CC-Link Link Scan Time (at communication speed of 10 Mbps) CC-Link parameter setting can be done with only GX Developer.
CC-Link is a high-speed and high-capacity network.The cyclic transmission time is not affected by irregular messagetransmission to the HMI products. It is possible to achieve highlystable control.
CC-Link guarantee consistent communication time.
CC-Link uses dedicated cables that support high-speed transmission up to 10 Mbps. These cables are also highly noise-resistant.
CC-Link achieves high reliability with dedicated cables.
When 64 stations are connected, the link scan time is a maximum of 1.2ms (at 2.5Mbps). Select 2.5Mbps, 625kbps or 156kbps depending on the transmission distance.
CC-Link/LT provides fast response.
CC-Link/LT is not required to make parameter setting.
CC-Link/LT specifies cables to application requirements.
<High-capacity Cyclic Transmission Data>
Comparison of communication data
CC-Link Ver2.0 can transmit a maximum of eight times the data capacitycompared with earlier CC-Link compatible products.
can control up to 8192 points and 4096 words.
CC-Link realizes simple distributed control.CC-Link provides highly stable cyclic transmission, which enables N:N communication between controller masters or local stations. This N:N communication method between controllers realizes a distributed control system for each system.
Simple controller communicationCC-Link Ver2.0-compatible analog module
"I need various devices on a single network."Diverse range of products supplied from manypartner manufacturers.
"I want to export our facilities and machinery overseas."CC-Link complies with various safety standards including UL standards.
Overall cable distance of CC-Link
CC-Link dedicated cable
CC-Link total extended distance can be as long as 1.2 km*. The transmission distance can be extended up to 13.2 km* when T-branch repeaters are used.
The total extended distance of the CC-Link cable is 1,200 m, and can be extended up to 13.2 km when repeaters are used.
* Maximum transmission distance when transmission speed is set to 156 kbps.
10 Mbps
5 Mbps
2.5 Mbps
625 kbps
156 kbps
100
400
900
160
4,300
4,480
4,4005,200
6,7009,900
7,60013,200
1,760
1,200
1,100
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 (m)
When a repeater is not used
When optical repeater (GI cable) is used
When a repeater (T-branch) is used
"I want to connect drives and servos."CC-Link allows GX Configurator-CC to read andwrite drives and servo parameters without aprogram, and perform monitoring and testing.
CC-Link also lets you...
CC-Link ensures...
CC-Link Ver.2 can control maximum eight times the data capacity compared with earlier CC-Link compatible products. CC-Link Ver.2 compatible analog modules are applicable to process control.
supports an extra broader range of needs.
CC-Link/LT Link Scan Time (at communication speed of 2.5 Mbps)
Link
sca
n tim
e (m
s)
0 20 40 600
0.5
1.0
1.5
2.0
2.5
Number ofstations
16-point mode
8-point mode
4-point modeDedicated flat cable VCTF cable Dedicated flexible cable
"I want a flexible production system." "I need complex control features."
"I want to connect lots of devices."
The total programming tool "GX Developer" with improved operability. Makes full use of the advantages of Windows R and enables you to set CC-Link parameters without a program.
"I need an easy network."
CC-Link simplifies data transfer to HMIs and ANDON with transient transmission (up to 960 bytes) and cyclic transmission.
CC-Link can connect HMIs and ANDONs by transient transmission.
"I want to connect HMIs and 'ANDONs.' "
"I need a reliable network."
"I want to connect between lines.""I want a network for building management."
"I want to connect lots of analog devices."
"I need high-speed sensor inputs."Dedicated flat cable, VCTF cable and dedicated flexible cable are available.
"I need widely used cables."
Troublesome network parameter setting is unnecessary. Thecommunication speed setting is required for the master module only. There is no need to set the communication speed on the remote station.
"I want to use remote I/O."
"I want a distributed control system."
CC-Link/LT ensures...
"CC-Link V2 has a double module connection capacity
* For details, refer to MELFANSweb.
Remote register (RWw)=
Lin
k scan
time
(ms)
0 20 40 600
1
2
3
4
5
6
Number of units [units]
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01234
5
6 7 8
90
12345
6 7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Remote I/O station only
Remote device station only (when all stations 1 station is occupied)
Local node/intelligent device station only (when all stations 1 station is occupied)
Data capacity Remote I/O (RX, RY)=8192 points each2048 words
(RWr)=2048 words (when Ver2.0 is used)
Up to 21 modules can be connected.
Up to 42 modules can be connected.
Ver 1.0
Ver 1.0(RX, RY) = 2048 points(RWw) = 256 words(RWr) = 256 words
Remote I/ORemote register
(RX, RY) = 8192 points each(RWw) = 2048 words(RWr) = 2048 words
Remote I/ORemote register
Dedicated fixed cable
Dedicated high flexible cable
Dedicated flexible cable
Built-in power cable
11 12
T-branch repeaters, wireless optical repeaters, optical repeaters, and repeater hubs are available with CC-Link. They enhance the freedom of application even at 10 Mbps.
Compact type remote I/O modules with 32, 16, 8, 4, and 2 I/O points are available. They can be mounted in six different directions, including ceiling mounting, front mounting, and flat surface mounting, and selected according to the environment where they are to be mounted and the application.
Direct mounting on machines in 6 directions
Online connector
CC-Link family remote I/O modules occupy a small footprint.
Specific connection to application requirements
Dedicated connectors of CC-Link family are designed to reduce wiring works, cost and wiring mistakes.
The round crimp terminal can be directly connected with the self-up screw by simply unfastening the terminal block screw.* The specifications depend upon a product.
Spring clamps allows for quick and easy connectivity.
Utilizing the industry-standard e-CON, sensors can be replacedindividually.
This connector adopts a lock mechanism that is easy to lock and unlock.You can connect single wires by simply pushing in the connector.
This type provides an easy and economical way of wiring. The waterproof type remote I/O module is housed in a protective structure conforming IP67. therefore it can be used without worry in an environment where water is present.
This is the industry's smallest connector in its class, and can be easily connected to a relay terminal or terminal block conversion module.
This is the industry's smallest connector in its class. Suited to fit compactly into main trunking ducts.
13 14
Round crimp terminal
Terminal block
Finger protection
Sensor
Switch
Connector
CL1-HLD
To I/O equipment or terminal block conversion unit
I want to arrange devices as I desire.
I want to save wiring time and cost.
CC-Link family products allows easy connection.By using online connectors for communication and power supply,it is possible to replace modules without stopping the communication.
I need assembly/ disassembly to be easy.
CC-Link protective cover protects I/O terminals.The protective cover can be easily attached and removed. The transparent material allows you to check the LEDs and wiring conditions.
I want to prevent trouble from foreign substances
CC-Link ensures easy setup and startup.CC-Link's auto-startup function allows you to start up the network without the need to set network parameters.
I need quick check-up.
Push-in connector type with terminator A6CON-TR11
Online connector for communicationA6CON-LJ5P
Connector
Simplified stopper structure
Single wire
Press in.
Soldering, wire sheath peeling, and screwing are no longer required.
Self-up screw
AJ65FBT-RPH
UNIT POWER
ERR.
L5 RDL6 RDL7 RDL8 RD
2.5M5M10M
156k625k
POWERRUN
SDRD
L1 RDL2 RDL3 RDL4 RD
LINK5
LINK1
LINK6
LINK2
LINK7
LINK3
LINK8
LINK4
87654
1
Remote I/O station, remote device stationIntelligent device station, local station, etc.
Master station
Repeater hub
Screw terminal block type Spring clamp terminal block type
Push-in connector type
40-pin connector type Waterproof connector type (M12)
MIL connector type Cable type
Ceiling mounting
Front mountingFront mounting
Flat surface mounting
Open sensor connector (e-CON)To sensor, valve
Sensor connector (e-CON) type
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CC-Link allows flexible installation.
Standby master station
Power supply noise test (AC/DC)
G4 module
Bundle noise test
Slave station isolation
Automatic return The "2-piece terminal block" allows modules to be replaced without stopping the CC-Link system.
Tested products Master station
Power line
Tested products Master station
Communication line (CC-Link)Communication line (CC-Link)
AJ65BT-G4-S3PC
PC PC PC
CC-Link
<Error invalid station setting>In the online mode, this setting temporarily prevents modules specified on GX Developer from being treated as data link faulty stations.
Station is made offline when a station error occurs, and the data link is continued on normal operating stations.
Stations disconnected from the datalink due to errors are automaticallyretuned to the data link once theyreturn to normal status.
By setting a local station as a standby master station, the data linkcan be continued even if an error occurs in the master station.
It is possible to check the data link status using special relays and registers. Hardware and line connection can be tested via offline tests.
* When connecting offline stations on CC-Link/LT, make sure that the PLC CPU is in a STOP status.
CC-Link family products provides one-step-ahead preventive maintenance.
Before trouble occurs... (preventive maintenance)
"I need network testing for preventive maintenance."
CC-link realizes minimal system shutdowns by "error invalid station setting," "slave station isolation," "automatic return," "standby master station," and "2-piece terminal block".
CC-Link provides enhanced RAS functions.
When trouble occurs... (troubleshooting)
"I don't want to stop my system."
The status of the CC-Link and CC-Link/LT networks can be monitored by just GX Developer.
CC-Link family Networks can be easily checked by GX Developer.
"I need easy troubleshooting."
By using the peripheral device connection module (AJ65BT-G4-S3) into the CC-Link system, it is possible to do network maintenance from sites away from PLC master.
CC-Link provides remote operation functions.
"I want to do network maintenance from sites away from the PLC master."
A conformance test is conducted for all products sold by CLPA partners. the test includes a power supply noise test and a bundle noise test.
CC-Link family compatible products are highly noise resistant guaranteed by conformance testing.
"I need high noise resistance."
There is no need to move the PC to where the PLC CPU is installed.
Online operation can be performedfrom programming software toany PLC at remote locations. Module fixed side
2-piece terminal block
Cables
Master station
Remote station Remote station Remote station
Standby master station
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Remote station Remote station
Master station
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Remote station
Remote station Remote station
Remote station
Master station
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Remote stationQ172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64PQ172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64PQ172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64P
Local station Local station Local station
Modules can be separated by unfastening the screws on both edges of the terminal block with the cable still connected.
15 16
17 18
"CC-Link is superior to existing networks"Realize the advantages of CC-Link.
Mr. A from the engineering section Mr. B from the production section
Mr. C from the maintenance section
Mr. A plans to expand his factory. The first challenge is total cable distance and communication stability. What interested him is that the network distance covered by the CC-Link network can be increased up to 900m at 625kbps, and transmission time is stable as well.
CC-Link is a consistent network.
"My current network distance is limited to 100m, and the transmission speed is unstable."
CC-Link scan time guideTransmission speeds and overall Network distance of other companies' networks
Mr. B is in charge of production engineering. He has been worried about utilization and high cost of the existing network. Therefore, he collected CC-Link information and compared it with other networks.
"Trunk cables and branch cables in the current network are different. Furthermore,trunk cables are expensive."
Reliability is the most important for him. He was pleased that the conformance test guaranteed the high noiseresistance of CC-Link.
"It concerns me that conformance testing is not mandatory in my current network."
CASE
1CASE
2
CASE
3
Feature 1
Feature 2
Regarding this issue, Mr. A learned that CC-Link compatible products quickly return to the network, and began to feel more attraction to CC-Link.
"It takes too long to reconnect network stations."
CC-Link eliminates the need to use different protocols.
CC-link is a single protocol.
"Our factory's networks are complex because they use various protocols. How about CC-Link?"
Protocol comparison
Feature 3
CC-Link offers quick return to the network system.
Feature 4
CC-Link is reliable because the conformance test is mandatory.
CC-Link is high-speed network and total cable distance is long distance. CC-Link is reasonably priced.Feature 1
Feature 3
Feature 2CC-Link is flexible to install.
"It is stressful to design the necessary power supply capacity of a network."
Also, using CC-Link, he easily realized "distributed control by establishing communication between controllers".
CC-Link is simple cotroll level network.
"I also need distributed control."Distributed control by simple inter-controller network
Feature 5
Remote I/O station only Local node/intelligent device station only (when all stations 1 station is occupied)
Remote device station only (when all stations 1 station is occupied)
(at communication speed 10 Mbps)
Max. 1200 m
Item
Cable diameter
Trunk/ Branch
CC-Link
7 mm
Trunk and branch
Thick cable: 12 mm
Trunk
Thin cable: 7 mm
Branch
(no repeater) (156 kbps) (125 kbps) (125 kbps)(500 kbps)
(250 kbps)
Other network
Cable comparison
Total cable length Max. 500 m Max. 100 m
Case Study
Protocol ABroadcast polling
system Protocol B
Protocol C Protocol D
CC-Link Other networks
CC-Link frees you from the need of calculation of the power supply capacity.
Mr. B used to be bothered by complicated calculations for the required power capacity. He soon learned that such bothersome calculation was not necessary.
Master station
Remote I/O
HMI
Remote I/O
Local station
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
STATION NO.X10 X1
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24 V 24G
B RATE
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Local station
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
PULL
USB
Q25HCPU QX10 QJ71BR11RUN
T.PASSSD
ERR
MNGD.LINKRDERR
RUNT.PASS
SDERR
MNGD.LINKRDERR
0123456789ABCDEF
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41POWERQ61P-A1
QJ61BT11RUNMST
SDERR.
L RUNS MSTRDL ERR
1
3
5
7
2
4
6
01
2345
6
7 8 90
1
2345
6
7 8 9A
B
CDEF012
3456789
Link scan time (m
s)
0 20 40 600
1
2
3
4
5
6
Number of units [units]
Othernetwork
100 m
900 m
At 156 kbps
At 600 kbps
Material handlingapplication
Building managementapplication
Semiconductor productionapplication
Parking lot application<FX3UC and CC-Link/LT combination>
Compliant to EES.
High noise resistance
High-speed transmission
Seamless communicationusing bridges
Connection of various devices (Inverter, HMI)
Wire savingSmall footprint
Improved workabilityby repeaters
Distributed control
The total cable distance up to13.2 km by using repeaters
Seamless communicationbetween Ethernet,
MELSECNET/H and CC-Link
Easy installation and setting up
Parameter-free setup work
High speed transmission
Building monitoring rooms
Ethernet
ME
LS
EC
NE
T/H
Cable specific tothe application requirement.
Wire savingSmall footprint
19 20
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Tec
hnic
alIn
form
atio
nS
uppo
rtM
aste
r/Lo
cal
25
31
91
107
109
113
115
117
119
133
23System ConfigurationExample
Product informationMaster/Local modules
Remote I/O modules
Analog modules
High-speed counter modules
Positioning modules
Peripheral device connection modules
RS-232 interface modules
PC interface boards
Repeater modules
Optional parts
Em
bede
d
22
Introduction of New ProductsIntroduction of New Products
Remote I/O modules
Source type
Spring clamp type
AJ65SBTB1B-16TE1AJ65SBTB1-32TE1AJ65SBTB1-32DTE1Output modules and I/O composite module with source type output form are added for the screw terminal block type.
A spring clamp terminal type repeater hub module, which realizes work hour savings, is added.
AJ65BTS-RPH
Repeater modules
P.45
P.123
P.45
P.52
21
The CC-Link compatible product lineup is expanded!
23 24
P.25
1
X0X1X2X3
Y0Y1Y2Y3
Y4Y5Y6Y7
OUT
0 1 2 3 4 5 6 7
P.191P.119P.31
P.136
P.91
P.199
P.107
Embedded modules
Optional parts P.187
Software P.199
Analog modules
Others
CC-Link-CC-Link/LTbridge modules
Repeater modules
P.107
P.109
P.191
P.195
P.113
P.115
Q172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64P
Partner product
Refer to the CC-Link PartnerAssociation catalog
Remote I/O modules
A lineup of products supporting variousapplications
Supporting various types of wiring suchas T-branching or cable extension
Repeater(T-branch)
To CC-Link/LT products pages
Spring clamp terminal block type repeater hub
Thin, waterproof type repeater hub
Embedded I/O modulesInterface boards
High-speed counter modulesPositioning modulesPeripheral device connection modulesRS-232 interface modules
Communication LSI dedicated to CC-LinkFX Series interface blockAC servo amplifier/interface moduleInvertersGOTesNumerical control unitsIndustrial robotsBreakerEnergy Measurement ModulePower measurement moduleMulti-circuit power meter moduleProtective relay
Optical repeaterWireless optical repeater
40 20 10 8 4 2 1 4 2 1
B RATESTATION NO.
ON
AJ65SBTB1-16DTDA DG +24V 24GDB SLD (FG)
PW L RUN L ERR X0 1 2 3 4 5 6 7 Y8 9 A B C D E F
YEYCYAY8X6X4X2X0
COM+X7X5X3X1
Y9 9B YD YF COM-
FX2N-32MR
0 1 2 3 4 5 6 710 11 12 13 14 15 16 17
IN
0 1 2 3 4 5 6 710 11 12 13 14 15 16 17
IN
POWERRUNBATT.VPROG.ECPU.E
RUNERR.
L RUNL ERR.
SDRD
POWER
RUNERR.
L RUNL ERR.
SD
RDRD
FX2N-16CCL-M
A1SP60 A1SP60 A1SJ61BT11
AD35ID1A1SJ61BT11
P.201
P.197
P.203
P.202
P.205
P.207
P.208
P.209
P.211
P.210
P.212
P.213
PC interface board
System Configuration Example
P.147
Master/Local modules
P.117
AJ65SBT-CLB
40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1
PW L RUN L ERR.
STATION NO. B RATE NOS TST MODE B RATE NC
ON
CC-Link
CC-Link/LT
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8
CC-Link
L RUN L ERR. L ERR.
CC-Link/LTCC-Link
CC-Link/LT
AJ65VBTCE3-16D
Special function modulesRD4
LINK4
RD3
LINK3
RD2
LINK2
RD1
LINK1
AJ65BTS-RPH
RD ERR.
IN/OUTLINK
POWER
RUN SD
RD6
LINK6
RD5
LINK5RD8
LINK8
DA
DB
DG
SLD
B RATE10
4
23
RD7
LINK7
+24V
24G
NC
(FG)
(FG)
FG
FG
NC
24G
+24
V
Cables Robots Solenoid valves HMI Thermostats ID controllers, etc.
For Q seriesQJ61BT11N
For QnAS seriesA1SJ61QBT11
For AnS seriesA1SJ61BT11
For FX seriesFX2N-16CCL-M
The available master module lineup accommodates all MELSEC CPU types.
Overview Model names
AnS master
QnAS master
FX master
Product name
Master/local module for Q series
Master/local module for QnA series
Master/local module for AnS series
Master/local module for FX series
QJ61BT11N
A1SJ61QBT11
A1SJ61BT11
FX2N-16CCL-M
Model
User's Manual SH-080394E (13JR64)
User's Manual SH-66722 (13J873)
User's Manual IB-66721 (13J872)
User's Manual JY992D93101 (09R710)
Related manual
Q masterP.29
P.30 P.31
P.27
25 26
Master/Local modulesMaster/Local modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbeded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
QJ61BT11N Master module (For Q series)
Part names and settings
0.46A
0.12kg
LED indicationThe data link state can be checked by the LEDstates.
Transmission rate/Mode setting switch
Station No. setting switch
Set the module's transmission rate and operation mode.
Terminal blockConnect the CC-Link dedicated cables for the data link.
Set the module's station No. Master station: 0 Local station: 1 to 64
Unit: mm
QCPU basic modelQCPU high performance model Process CPURedundant CPU
Network module
CP
U m
odul
e
Connectable CPU modelsMax. No. of mountable modules
GX Developer setting24444
Dedicated instruction setting2
6464--
Q00JCPU,Q00CPU,Q01CPUQ02CPU,Q02HCPU,Q06HCPU,Q12HCPU,Q25HCPUQ12PHCPU,Q25PHCPUQ12PRHCPU, Q25PRHCPUQJ72LP25-25, QJ72LP25G, QJ72BR15
Q master
External dimensions
Applicable CPU
Internal current consumption:
Weight:
A1SJ61QBT11 Master module (for QnAS series)
Part names and settings
CPU moduleNetwork module
Connectable CPU modelsQ2ASCPU (S1), Q2ASHCPU (S1)A1SJ72QLP25, A1SJ72QBR15
QnAS master
0.4A
0.25kg
Unit: mm
External dimensions
Applicable CPU
Internal current consumption:
Weight:
NC
MODE
X1
X10
RUNMST
SDERR.
L RUNQJ61BT11N
S MSTRDL ERR.
STATIONNO.
DA
NC
SLD
DB
DG
1
3
5
2
4
6
7
(FG)
08
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
27.4
98
90
RUNERR.
MSTS MSTL RUNL ERR.SDRD
ON: The module is normalON: Communication error at all stationsFlashing: Data link error occurred atsome station.ON: Set as the master stationON: Set as the standby master stationON: Performing data linkON: Communication error (its own station)ON: Sending dataON: Receiving data
LED name Description
0123456789ABCDEF
156kbps625kbps2.5Mbps
5Mbps10Mbps156kbps625kbps2.5Mbps
5Mbps10Mbps156kbps625kbps2.5Mbps
5Mbps10Mbps
No. Transmission rate
Setting is inhibited.
Online
Hardware test
Line testWhen station NO. setting switch is 0 :
Line test 1When station NO. setting switch is 1 to 64 :
Line test 2
Mode
NC
MODE
X1
X10
RUNMSTSD
ERR.
L RUNQJ61BT11N
S MSTRDL ERR.
STATIONNO.
DA
NC
SLD
DB
DG
1
3
5
2
4
6
7
(FG)
08
F
7
E
6
D
5
C
4
B
3
A
2
9
105
9
4
8
3
7
26
105
9
4
8
3
7
2
6
1
RUNMSTSD
ERR.
L RUNQJ61BT11N
S MSTRDL ERR. X1
X10
STATION NO.
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
MODE 08
F
7
E
6
D
5
C
4
B
3
A
2
9
1
23.993.66.5
130
34.5
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61QBT11
A1SJ61QBT11
12
34
56
78
O N
K S
D 0 8
STATION NO. MODE
X10
X1
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
08
F
7
E
6
D
5
C
4
B
3
A
2
9
1
1/4 2/3
LED indication
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61QBT11
A1SJ61QBT11
12
34
56
78
O N
K S
D 0 8
STATION NO. MODE
X10
X1
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D
5 C
4
B
3
A
2
9
1
1/4 2/3
A1SJ61QBT11RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
STATION NO.
X10
X1
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
MODE
0
8
F
7
E
6
D
5 C
4
B
3
A
2
9
1
12
34
56
78
O N
K S
D 0 8
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
1/4 2/3
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
05
9
4
8
3
7
2
6
1
RUNERR.
MSTS MSTLOCALCPU R/WERRORL RUNL ERR.SDRD
ON: The module is normalON: Communication error for all stationsFlashing: Data link error occurred at some station.ON: Set as master stationON: Set as standby master stationON: Set as local stationON: Communicating with PLC CPU (FROM/TO)Lights up when an error occursON: Performing data linkON: Communication error (its own station)ON: Sending dataON: Receiving data
LED name Description
Station No. setting switchSet the module's station No. Master station : 0 Local station : 1 to 64 Standby master station : 1 to 64
* When the mode switch is set to the remote I/O network mode, set the number of connected modules.
01234
156kbps625kbps2.5Mbps5Mbps
10Mbps
No. Transmission rate
Transmission rate setting switchSet the module's transmission rate.
Mode setting switchSet the module's operation state.
Conditions setting switch
SW1
SW4
SW5SW6 1 station
2 stations*3 stations*4 stations
SW6OFFONONOFF
SW5OFFOFFONON
Station type
No. ofoccupiedstations
Data input from datalink error station
OFF: Master/Local stationON: Standby master stationOFF: ClearON: Hold
Supported by the A1SJ61QBT11 hardware version G or later.For other versions, the number of occupied stations is set bySW5 only.OFF: 1 station occupiedON: 4 stations occupiedSW6 must be always OFF since its use is not allowed.
*
No. Setting item Switch Status
Terminal blockConnect the CC-Link dedicated cables for the data link.
No. of occupied stations
0
1
2
Online(Remote network mode)
Online(Remote I/O network mode)
Offline
Select this when performing the datalink in the remote network mode.Select this when performing the datalink in the remote I/O network mode.)The data link is disconnected.
No. Name Description
27 28
Master/Local modulesMaster/Local modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
A1SJ61BT11 Master module (for AnS series)
Part names and settings
CPU module
Network module
Connectable CPU modelsA1SCPU, A1SHCPU, A1SJCPU (S3), A1SJHCPU, A1SCPUC24-R2, A2SCPU, A2SHCPU, A2USCPU (S1), A2USHCPU-S1A1SJ72QLP25, A1SJ72QBR15
AnS master
0.45A
0.4kg
Unit: mm
External dimensions
Applicable CPU
Internal current consumption:
Weight:
FX2N-16CCL-M Master block (for FX series)
Part names and settings
FX master
External dimensions
Applicable CPU
Internal current consumption: 5VDC supplied by the module itself.
(The 5VDC supply of the PLC is not used.)
External current consumption: 150mA (24VDC)
Weight: 0.4kg
Unit: mm
CPU moduleConnectable CPU models
FX1N, FX2N, FX3U SeriesFX1NC, FX2NC, FX3UC Series (FX2NC-CNV-IF required)
23.993.66.5
130
34.5
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61BT11
A1SJ61BT11
12
34
56
78
O N
K S
D 0 8
STATION NO. MODE
X10
X1
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
08
F
7
E
6
D
5
C
4
B
3
A
2
9 1
ISM SFM
1/4 2/3
LED indication
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61BT11
A1SJ61BT11
12
34
56
78
O N
K S
D 0 8
STATION NO. MODE
X10
X1
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
05
9
4
8
3
7
2
6
105
9
4
8
3
7
26
105
9
4
8
3
7
2
6
1
0
8
F
7
E
6
D5 C
4
B
3
A
2
9
1
ISM SFM
1/4 2/3
A1SJ61BT11RUNERR.MST
S MSTLOCAL
CPU R / WL RUNL ERR.
SDRD
SWM / SPRMTIMELINE
ERROR
STATION NO.
X10
X1
05
9
4
8
3
7
2
6
105
9
4
8
3
7
2
6
1
MODE
0
8
F
7
E
6
D
5 C
4
B
3
A
2
9
1
12
34
56
78
O N
K S
D 0 8
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
1/4 2/3
B RATE
0 156K
1 625K
2 2. 5M
3 5M
4 10M
05
9
4
8
3
7
2
6
1
RUNERR.
MSTS MSTLOCALCPU R/WERRORL RUNL ERR.SDRD
ON: The module is normalON: Communication error for all stationsFlashing: Data link error occurred at some station.ON: Set as master stationON: Set as standby master stationON: Set as local stationON: Communicating with PLC CPU (FROM/TO)Lights up when an error occursON: Performing data linkON: Communication error (its own station)ON: Sending dataON: Receiving data
LED name Description
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
No. Transmission rate
Transmission rate setting switchSet the module's transmission rate.
Mode setting switchSet the module's operation state.
Conditions setting switch
SW1
SW5SW6
SW8
1 station2 stations*3 stations*4 stations
SW6OFFONONOFF
SW5OFFOFFONON
Station type
No. ofoccupiedstations
Module mode
OFF: Master/Local stationON: Standby master station
OFF: Intelligent modeON: I/O mode
Supported by the A1SJ61BT11 hardware version G or later.For other versions, the number of occupied stations is set by SW5 only.OFF:1 station occupiedON: 4 stations occupiedSW6 must be always OFF since its use is not allowed.
*
No. Setting item Switch Status
Terminal blockConnect the CC-Link dedicated cables for the data link.
The data link state can bechecked by the LED states.
No. of occupied stations
Station No. setting switchSet the module's station No. Master station: 0 Local station: 1 to 64 Standby master station: 1 to 64
* When the mode switch is set to the remote I/O network mode, set the number of connected modules.
0
1
2
Online(Remote network mode)
Online(Remote I/O network mode)
Offline
Select this when performing the datalink in the remote network mode.Select this when performing the datalink in the remote I/O network mode.)The data link is disconnected.
No. Name DescriptionLED indication
RUN
ERR.
MSTTEST1TEST2L RUNL ERR.
POWERSW
M/SPRMTIME
LINE
SDRD
ON: The module is normalOFF: Watch dog timer errorIndicates the status of the communication withthe station specified by the parameter.ON: Communication errors at all stationsFlashing: Data link error occurred at some stationON: Set as master stationIndicates the test result.Indicates the test result.ON: Performing data link (its own station)ON: Communication error (its own station)Flashing: Some switch setting has been changed
with the power on.Turns ON when external power of 24V DC is supplied.Some switch setting is erroneous.ON: A master station already exists on the same network.ON: Parameter setting is erroneous.ON: Data link monitoring timer has been activated.
(Error at all stations)ON: A cable is disconnected, or the transmission
path is affected by noise, etc.ON: Sending dataON: Receiving data
LED name Description
No.SW1 to 3
SW4SW5 to 8
Setting
Station No. setting switch
ON
87
65
43
21
F EDCBA
9876543210
90
1
2 3 45
6
78
901 2345678
9 8 7
65
432
10
FX2N-16CCL-M
FG24-
24+
SLD
DG
DA
DB
CLR
----
--
87654
--
--
--
321
SW OFF ON
- -HLD
0
10M5M
2.5M625K156K
4
23
1
B RATE
MODE
NO.STATION
X1
X10
RORRE
RDSD
LINETIMEPRMM/SSW
POWER
TEST2TEST1MST
L RUNL ERR.
ERR.RUN
ON
87
65
43
21
CLR
----
--
87654
--
--
--
321
SW OFF ON
- -HLD
9 8 7
65
432
10
F EDCBA
987
6543210MODE
90
1 2345
678
90
1 2345
678
NO.STATION
X1
X10
ERROR
Conditions setting switch
(Not used)Input data status of data link error station(Not used)
No.023456
SettingOnlineOfflineLine test 1Line test 2Parameter check testHardware test
Mode setting switch
Transmission rate setting switch
Terminal blockConnect a twisted-pair cable and power supply for the data link.
B RATE
01234
156K 625K 2.5M
5M 10M
Set the module's station No.
The data link state can be checked by the LED states.
Set the module's operation mode
Set the module's transmission rate.
01234
156kbps625kbps2.5Mbps5Mbps
10Mbps
No. Transmission rate
Set the operation conditions
9
8775±0.2 (Mounting dimension)
80±0
.2 (
Mou
ntin
g di
men
sion
)
85
90
MIT
SUBI
SHI
FX2N-16CCL-M
RORRE
RDSD
LINETIMEPRMM/SSW
POWER
L ERR.L RUN
TEST2TEST1
MSTERR.RUN
DIN rail (35mm) mounting groove
Inside of top cover
ON
87
65
43
21
F EDCBA
9876543210
90
1
2 3 45
6
78
901 2345678
9 8 7
65
432
10
FX2N-16CCL-M
FG24-
24+
SLDDG
DADB
CLR
----
--
87654
--
--
--
321
SW OFF ON
- -HLD
0
10M5M
2.5M625K156K
4
23
1
B RATE
MODE
NO.STATION
X1
X10
RORRE
RDSD
LINETIMEPRMM/SSW
POWER
TEST2TEST1MST
L RUNL ERR.
ERR.RUN
2- 4.5
29 30
Master/Local modulesMaster/Local modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
From a variety of products, you can select the optimum model that matches the connection method and I/Ospecifications of external devices.
Overview How to read the model name
Selection Considerations
Screw T. block
Spring clamp
WaterproofWaterproof
40-pin
Sensor
AJ65 BT1 3 4 5 62
I/O specifications 5
6 I/O types
Module type 1
2 Cable specifications
I/O points 3 4External load connection
Resistance Load LoadInductance
Outputmodule
Outputmodule
Screw terminal block type
Spring clamp terminal block type
Push-in connector type
Screw/2-piece terminal block type
Sensor connector type (e-CON)
40-pin FCN connector type
Waterproof connector type
Low profile waterproof typeCompact typeConnector type (compact)Standard typeModule type
F:S:V:
None:M:
Twisted cable (CC-Link dedicated cable)
(5)
T:
2-wire output type with 8 M12 waterproof connecters2- to 4-wire input type with 8 M12 waterproof connecters2- to 4-wire input type or 2-wire output typewith 8 M12 waterproof connectersTerminal block, single wire typeTerminal block, single wire type (2 common)Terminal block, 2-wire typeTerminal block, 3-wire typeTerminal block, 3-wire type input or 2-wire output typePush-in connector, single wire typePush-in connector, 4-wire type40-pin connector (FCN connector), single wire typePush-in connector, 2-wire typePush-in connector, 3-wire typeWaterproof connector, 4-wire typeLead type, single wire typeSpring clamp terminal block, 2-wire typeSpring clamp terminal block, 3-wire typeSpring clamp terminal block, 3-wire type inputor 2-wire output type Sensor connector (e-CON), 2-wire typeSensor connector (e-CON), 2-wire typeSensor connector (e-CON), 3-wire output or 2-wire input types
A2:A4:
A42:
B1:B1B:
B2:B3:
B32:C1:C4:
CF1:CU2:CU3:W4:
L1N:S2:S3:
S32:
CE2:CE3:
CE32:
8 points16 points32 points
8:16:32:
100VAC input24VDC inputRelay outputTriac outputTransistor output24VDC input, transistor output
A:D:R:S:T:
DT:
Negative common (source) input type, source output type
E:
(1)
(2)
(3)
(4)
P.59 P.65
P.71 P.79
P.85
P.37 P.53Screw T. block
Push-in
31 32
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Since the following additional output modules do not have the short-circuit protection function, provide the function externally:AJ65SBTB1-16T1, AJ65SBTB1-32T1, AJ65SBTB1-8T1, AJ65SBTB2-8T1, AJ65SBTB2-16T1, AJ65SBTC1-32T1, AJ65SBTB1-16DT2, AJ65SBTB1-32DT2, AJ65SBTB1-16DT3, AJ65SBTB1-32DT3, AJ65SBTB32-8DT2, AJ65SBTB32-16DT2, AJ65SBTC4-16DT2, AJ65SBTC1-32DT2, AJ65SBTC1-32DT3, AJ65VBTS2-16T, AJ65VBTS2-32T, AJ65VBTS32-16DT and AJ65VBTS32-32DT
These modules are remote I/O modules dedicated to the CC-Link system. Do not connect them to any other data link system such as the MELSECNET/MINI.For the compact type remote I/O modules, 32 points are assigned to one station.When assigning a 16-point or 8-point module, the rest of 16 or 24 points is left empty and is not used.When driving inductive loads with an output module, the maximum switching frequency must be 1 second or more for each of ON and OFF.If a counter or timer containing a DC/DC converter is used as a load for a transistor output module whose maximum load current is 0.1A, an inrush current will flow periodically when the module is ON or in operation. Therefore, selecting a module based on the average current only may cause a failure.To avoid the effect of the inrush current in the case above, connect a resistance or inductance to the load in series, or use an output module of a larger maximum load current.
AC input
pts8 -wire2100VAC Triac
output
pts8 -wire20.6A
AC input
pts16 -wire2100VAC Triac
output
pts16 -wire20.6A
DC input
pts8 -wire124VDC
DC input
pts8 -wire324VDC
DC input
pts4 -wire324VDC ProtectionTransistor
output
pts4 -wire20.5A
DC input
pts4 -wire324VDC
Transistoroutput
pts4 -wire20.5A
DC input
pts16 -wire124VDC
DC input
pts16 -wire124VDC
DC input
pts16 -wire324VDC
DC input
pts32 -wire124VDC
DC input
pts32 -wire124VDC
DC input
pts8 -wire124VDC ProtectionTransistor
output
pts8 -wire10.5A
DC input
pts8 -wire124VDC ProtectionTransistor
output
pts8 -wire10.5A
DC input
pts8 -wire124VDC
Transistoroutput
pts8 -wire10.5A
DC input
pts8 -wire124VDC
Transistoroutput
pts8 -wire10.5A
DC input
pts8 -wire324VDC ProtectionTransistor
output
pts8 -wire20.5A
Protection
Protection
Transistoroutput
pts8
Transistoroutput
pts8
-wire10.5A DC input
pts8 -wire324VDC
Transistoroutput
pts8 -wire20.5A
-wire10.5A
Transistoroutput
pts8 -wire20.5A
Transistoroutput
pts8 -wire20.5A
DC input
pts16 -wire124VDC ProtectionTransistor
output
pts16 -wire10.5A
DC
16 1DC24V
10.5ADC input
pts16 -wire124VDC ProtectionTransistor
output
pts16 -wire10.5A
DC input
pts16 -wire124VDC ProtectionTransistor
output
pts16 -wire10.5A
DC input
pts16
DC input
pts16DC input
pts16
-wire124VDC ProtectionTransistor
output
pts16 -wire10.5A
DC input
pts16 -wire124VDC
Transistoroutput
pts16 -wire10.5A
ProtectionTransistoroutput
pts16 -wire10.5A
Transistoroutput
pts16 -wire10.5A
-wire124VDC
ProtectionTransistoroutput
pts16 -wire20.5A
-wire224VDC
Transistoroutput
pts16 -wire20.5A
Transistoroutput
pts16 -wire10.5A
Transistoroutput
pts16 -wire20.5A
Relayoutput
pts16 -wire22.0A
ProtectionTransistoroutput
pts32 -wire10.5A
Transistoroutput
pts32 -wire10.5A
ProtectionTransistoroutput
pts8
Transistoroutput
pts16
-wire10.1A
DC input
pts8 -wire124VDC
Transistoroutput
pts8 -wire10.5A
DC input
pts8 -wire224VDC
Transistoroutput
pts8 -wire20.5A
Protection
-wire10.1A
Transistoroutput
pts16 -wire10.1A
Transistoroutput
pts32 -wire10.1A
Relayoutput
pts8
Relayoutput
pts16
-wire22A
-wire22A
DC input
pts8 -wire224VDC
Relayoutput
pts8 -wire22.0A
High speedinput
High speedinput
High speedinput
High speedinput
High speedinput
High speedinput
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Lowleakage
Screw T. block
Screw T. block
Model names
ModelFeatures
Input Output OthersType
Inpu
t mod
ule
Out
put m
odul
e
Out
put m
odul
e
Page
AJ65SBTB2N-8A
AJ65SBTB2N-16A
AJ65SBTB1-8D
AJ65SBTB3-8D
AJ65SBTB1-16D
AJ65SBTB1-16D1
AJ65SBTB3-16D
AJ65SBTB1-32D
AJ65SBTB1-32D1
AJ65SBTB1-8T
AJ65SBTB1-8T1
AJ65SBTB2-8T
AJ65SBTB2-8T1
AJ65SBTB1-16T
AJ65SBTB1-16T1
AJ65SBTB2-16T
AJ65SBTB2-16T1
AJ65SBTB1-32T
AJ65SBTB1-32T1
AJ65SBTB1-8TE
AJ65SBTB1-16TE
AJ65SBTB1B-16TE1
AJ65SBTB1-32TE1
AJ65SBTB2N-8R
AJ65SBTB2N-16R
38
38
39
39
40
40
40
41
41
41
41
42
42
42
42
43
43
43
43
44
44
45
45
46
46
ModelFeatures
Input Output OthersType Page
AJ65SBTB2N-8S
AJ65SBTB2N-16S
AJ65SBTB32-8DT
AJ65SBTB32-8DT2
AJ65SBTB1-16DT
AJ65SBTB1-16DT1
AJ65SBTB1-16DT2
AJ65SBTB1-16DT3
AJ65SBTB32-16DT
AJ65SBTB32-16DT2
AJ65SBTB1-32DT
AJ65SBTB1-32DT1
AJ65SBTB1-32DT2
AJ65SBTB1-32DT3
AJ65SBTB1-32DTE1
AJ65BTB1-16D
AJ65BTB2-16D
AJ65BTB1-16T
AJ65BTB2-16T
AJ65BTB2-16R
AJ65BTB1-16DT
AJ65BTB2-16DT
AJ65BTB2-16DR
47
47
48
48
49
49
49
49
50
50
51
51
51
51
52
54
54
55
55
56
57
58
58
For the icons, refer to pages 223 to 224.
I/O c
ompo
site
mod
ule
I/O c
ompo
site
mod
ule
Inpu
t mod
ule
Out
put m
odul
e
Scr
ew/2
-pie
ce te
rmin
al b
lock
type
33 34
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts16 -wire324VDC
DC input
pts32 -wire324VDC
DC input
pts16 -wire124VDC ProtectionTransistor
output
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts32
Transistoroutput
pts32
-wire10.1A
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts32
Transistoroutput
pts32
-wire20.5A
DC input
pts16 -wire124VDC Protection
-wire10.1A
Transistoroutput
pts32
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
-wire20.5A
DC input
pts16 -wire124VDC
-wire10.1A
DC input
pts16 -wire124VDC
-wire10.1A
DC input
pts8 -wire324VDC
-wire20.5A
DC input
pts16 -wire324VDC
-wire20.5A
DC input
pts32 -wire124VDC
DC input
pts8 -wire324VDC Vertical
DC input
pts16 -wire324VDC Vertical
DC input
pts32 -wire324VDC Vertical
Protection
-wire10.1A
DC input
pts16 -wire124VDC
Protection
-wire10.1A
DC input
pts16 -wire124VDC
Protection
-wire10.1A Vertical installationProtection
-wire10.1A Vertical
DC input
pts16 -wire224VDC
-wire424VDC
to
DC input
pts16 -wire224VDC
-wire424VDC
to
Protection
-wire20.1A Vertical
DC input
pts8 -wire324VDC Protection
-wire20.1A Vertical
Transistoroutput
pts16DC input
pts16 -wire324VDC Protection
-wire20.1A Vertical Protection
-wire20.5A
Protection
-wire21.0A
DC input
pts8 -wire324VDC Vertical
DC input
pts8 -wire224VDC
-wire424VDC ProtectionTransistor
output
pts8
Transistoroutput
pts8
Transistoroutput
pts8
-wire20.5A
toDC input
pts16 -wire324VDC
DC input
pts16 -wire424VDC
DC input
pts16 -wire424VDC
Vertical
DC input
pts8 -wire224V DC
-wire424V DC
Protection
-wire21.0A
to
DC input
pts32 -wire124VDC
DC input
pts16Input V.
24VDC
DC input
pts32Input V.
24VDC
DC input
pts8Input V.
24VDC
DC input
pts32 -wire124VDC
Protection
-wire20.1A Vertical
Protection
Protection
Protection
0.1AInput load
current
0.1AInput load
current
0.1AInput load
current
Protection
-wire20.1A Vertical
Protection
-wire10.1A
-wire10.1A
DC input
pts8 -wire424VDC Protection
-wire40.5A
DC input
pts8 -wire424VDC
-wire40.5A
High speedinput
Lowleakage
Lowleakage
High speedinput
High speedinput
Lowleakage
Lowleakage
Model names
Embeded
Refer to page191 and
later pages.
ModelFeatures
Input Output OthersType Page
AJ65VBTS3-16D
AJ65VBTS3-32D
AJ65VBTS2-16T
AJ65VBTS2-32T
AJ65VBTS32-16DT
AJ65VBTS32-32DT
AJ65VBTCE3-8D
AJ65VBTCE3-16D
AJ65VBTCE3-32D
AJ65VBTCE2-8T
AJ65VBTCE2-16T
AJ65VBTCE32-16DT
AJ65VBTCE32-32DT
AJ65VBTCU3-8D1
AJ65VBTCU3-16D1
AJ65SBTC4-16DN
AJ65SBTC4-16DE
AJ65SBTC1-32D
AJ65SBTC1-32D1
AJ65VBTCU2-8T
AJ65VBTCU2-16T
AJ65SBTC1-32T
AJ65SBTC1-32T1
60
61
61
62
63
64
66
67
67
68
68
69
70
73
73
74
74
75
75
75
75
76
76
ModelFeatures
Input Output OthersType Page
AJ65SBTC4-16DT
AJ65SBTC4-16DT2
AJ65SBTC1-32DT
AJ65SBTC1-32DT1
AJ65SBTC1-32DT2
AJ65SBTC1-32DT3
AJ65SBTCF1-32D
AJ65SBTCF1-32T
AJ65SBTCF1-32DT
AJ65VBTCF1-32DT1
AJ65FBTA4-16D
AJ65FBTA4-16DE
AJ65FBTA2-16T
AJ65FBTA2-16TE
AJ65FBTA42-16DT
AJ65FBTA42-16DTE
AJ65MBTL1N-16D
AJ65MBTL1N-32D
AJ65MBTL1N-16T
AJ65MBTL1N-32T
AJ65MBTL1N-16DT
77
77
78
78
78
78
81
81
82
83
87
87
88
88
89
89
192
192
193
193
194
For the icons, refer to pages 223 to 224.
Inpu
t mod
ule
Inpu
t mod
ule
Inpu
t mod
ule
Out
put m
odul
eO
utpu
t mod
ule
Out
put m
odul
eI/O
com
posi
tem
odul
e
I/O c
ompo
site
mod
ule
I/Oco
mpo
site
mod
ule
Inpu
t mod
ule
Inpu
t mod
ule
Inpu
tm
odul
eO
utpu
t mod
ule
Out
put m
odul
eO
utpu
tm
odul
eI/O
com
posi
tem
odul
eI/O
com
posi
tem
odul
eI/O
com
posi
te m
odul
eSpring clamp
Sensor
Push-in
Push-in
Push-in
40-pin
WaterpraterproofoofWaterproofI/O c
ompo
site
mod
ule
35 36
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Screw terminal block type
Overview
Part names and functions
Features
Screw terminal block type
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage/Frequency
Rated input current
Operating voltage range
Input derating
Inrush current
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response time
Wiring method for common
No. of stations occupied
I/O module power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65SBTB2N-16AUnit: mm
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage/Frequency
Rated input current
Operating voltage range
Input derating
Inrush current
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response time
Wiring method for common
No. of stations occupied
I/O module power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65SBTB2N-8AScrew T. block
Screw T. block
Module power supply
DADBDGSLD+24VFG24G
21
34567
98 X0
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM B
COM BCOM A
X1
X2
X3
X4
X5
X6
X7
X8
X9
XA
XB
XC
XD
XE
XF
1011121314
1615
17181920
2221
23242526
2827
29303132
3433
35363738
4039
41
100VAC
Insulation
R R
R
DC/DC
X4 X5 X6 X7 X8 X9X3X2X1X0
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMACOM
B
XE XFXDXCXBXA
The use of self-up screws reduces wiring works. The round crimp terminal can be directly connected with the self-up screw by simply unfastening the terminal block screw.The charging area is covered by a finger protector on the upper part of the terminal block so that people cannot touch it.Direct mounting on machine in 6 directions.
AC input
pts8 -wire2100VAC
-wire2100VACAC input
pts16
Screw T. block
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
Description
8 points
Photocoupler
100 to 120VAC 50/60Hz
Approx. 7mA (100VAC 60Hz)
85 to 132VAC ((50/60Hz ±3Hz (within 5% of distortion rate))
100% simultaneous ON (at 110VAC)
60% simultaneous ON (at 132VAC)
Max. 200mA within 1ms (at 132VAC)
80VAC/3.5mA or higher
30VAC/1.7mA or lower
Approx. 15k (60Hz), Approx.18k (50Hz)
20ms or less (at 100VAC 60Hz)
20ms or less (at 100VAC 60Hz)
8 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
1780VAC rms/3 cycles across AC external
terminals and ground (altitude 2000m)
500VAC for 1 minute across DC external
terminals and ground
10M or more by 500VDC insulation resistance
tester across AC external terminals and ground
10M or more by 500VDC insulation resistance
tester across DC external terminals and ground
0.2
Description
16 points
Photocoupler
100 to 120VAC 50/60Hz
Approx. 7mA (100VAC 60Hz)
85 to 132VAC ((50/60Hz ±3Hz (within 5% of distortion rate))
100% simultaneous ON (at 110VAC)
60% simultaneous ON (at 132VAC)
Max. 200mA within 1ms (at 132VAC)
80VAC/5mA or higher
30VAC/1.7mA or lower
Approx. 15k (60Hz), Approx.18k (50Hz)
20ms or less (at 100VAC 60Hz)
20ms or less (at 100VAC 60Hz)
16 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (When 24VDC and all point is on)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
1780VAC rms/3 cycles across AC external
terminals and ground (altitude 2000m)
500VAC for 1 minute across DC external
terminals and ground
10M or more by 500VDC insulation resistance
tester across AC external terminals and ground
10M or more by 500VDC insulation resistance
tester across DC external terminals and ground
0.25
AJ65SBTB1-8D
X0 1 2 3 4 5 6 7
X0 X2 X4 X6
X1 X3 X5 X7
DA DG +24V 24G
DB SLD (FG)
COM
COM
124124102040 8
ON
STATION NO. B RATE
LED indication
PWL RUN
L ERR
X0 to 1F
LED name DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.ON: Communication errorFlashing at regular intervals:
The station No. and/or transmission rate switch setting has been changed while the power is on.
Flashing irregularly:The terminating resistor setting is incorrect, or the module and CC-Link dedicated cables are being affected by noise.
OFF: Communication is normal.Indicates the input ON/OFF status.Turns ON and OFF when the input is ON or OFF respectively.
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
Transmission rate setting switch
Station No. setting switch
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Settingvalue Transmission rate
DIN rail mounting hookThis hook is used to mount the module on the DIN rail.
Terminal block
Unit: mm
98
1011121314
1615
1718192021
X0COM BX1COM BX2COM BX3COM BX4COM BX5COM BX6COM BX7COM BCOM ACOM B
22232425
DADBDGSLD+24VFG24G
21
34567
R R
R
Module power supply
Insulation
100VAC
DC DC
X4 X5 X6 X7
COMB
X3
COMB
X2
COMB
X1
COMB
X0
COMB COMB COMB COMB
COMA
COMB
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
COMBCOMBCOMBCOMBCOMBCOMBCOMBCOMB
AJ65SBTB2N-8A
COMB
X3X2X1X0 X7X6X5X4 COMA
6 754321X0
24G
(FG)DB
DA +24V
SLD
DG
ON
4STATION NO.
1B RATE
12248102040
AJ65SBTB2N-16A
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
X0 1 2 3 4 5 6 7 X8 A B C D E9 F
X1X0 X2 X3COMB
X4 X8X5 X6 X7 X9 XA XB XC XD XE XF+24V 24G(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
(Mounting pich)
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMBCOMBCOMB
COMA
DIN rail center
37 38
Remote I/O modulesRemote I/O modulesProduct information
* The actual modules may slightly differ in shapes from the photos shown.
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Input module
AJ65SBTB3-8DUnit: mm
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Screw T. block
Input module
AJ65SBTB1-8D
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Unit: mm
Screw T. block
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Input module
AJ65SBTB1-16D
AJ65SBTB1-16D AJ65SBTB1-16D1
Unit: mm
Input module
AJ65SBTB1-16D1
Description
Screw T. block
Screw T. block
Input module
AJ65SBTB3-16DUnit: mm
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Screw T. block
Module powersupply
DADBDGSLD+24VFG24G
21
34567
Insulation
X0COMAX1COMBX2COMAX3
1011121314
COMBX4COMAX5COMB
1615
171819
X620COMAX7COMBX8COMA
2221
232425
X926COMBXACOMAXBCOMB
2827
293031
XC32COMAXDCOMBXECOMA
3433
353637
XF38COMBDC24ADC24B
4039
4124VDC
89
R
R2 wiresensor
3 wiresensor
Source, sink
DC DC
DC input
pts8 -wire124VDC
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
OFF ON
ON OFF
OFF ON
ON OFF
Description
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
8 points/common (2)
(terminal block single wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
30mA or less (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
IP2X
0.14
Description
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
8 points/common (terminal block 3-wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or less (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external
terminals and ground for 1 min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
IP2X
0.18
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common (2)
(terminal block single wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower
(at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.18
Approx. 5mA
15VAC/3mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
40mA or lower
(at 24VDC,with all points ON)
Description
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common (terminal block 3-wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
IP2X
0.25
Module power supply
DC DC
DADBDGSLD+24VFG24G
21
34567
Insulation
X0COMAX1COMBX2COMAX3
98
1011121314
COMBX4COMAX5COMBX6COMA
1615
1718192021
X7COMBDC24ADC24B
22232425
24VDC
R
R
3 wiresensor
2 wiresensor
Source, sink
X4 X5 X6 X7 DC24A
COMA
X3
COMB
X2
COMA
X1
COMB
X0
COMA COMB COMA COMB DC24B
X0 X2 X4 X6 COM
X1 X3 X5 X7 COM
DADBDGSLD
DC DC+24VFG24G
X0X1X2X3X4X5X6X7COMCOM
21
34567
98
1011121314151617
R
R
R
R
Insulation
24VDC
Module power supply
X8 XA XC XE COM
X9
X6
X7
X4
X5
X2
X3
X0
X1 XB XD XF COM
DADBDGSLD
DC DC+24VFG24G
X0X1X2X3X4X5X6X7X8X9XAXBXCXDXEXFCOM
21
34567
98
10111213141516171819202122232425 COM
R
R
R
R
Insulation
24VDC
Module power supply
X4 X5 X6 X7 X8 X9X3X2X1X0
COMA
COMB
COMA
COMB
COMA
COMB
COMA
COMB
COMA
COMB
COMA
COMB
COMA
COMB
COMA
COMB
DC24A
DC24B
XE XFXDXCXBXA
+24V 24G(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB1-8D
COMX7X5
COMX6X4
X3
5 764321X0
X1
X2X0
450
16.5
40
87.3
78.3 +0.04 0 (Mounting pitch)
2-4.5x5.1 mounting hole(M4 mounting screw)
About 105˚
7.5
7.9
DIN rail center
DC24B
DC24AX4 X5 X6 X7
X0 1
X0 X1 X2 X3
COMA
2 3 4 5 6 7
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB3-8D
COMB COMA COMB COMA COMB COMA COMB
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
AJ65SBTB3-16D
X0 1 2 3 4 5 6 7 X8 A B C D E9 F
X1X0 X2 X3
COMA
X4 X8X5 X6 X7 X9 XA XB XC XD XE XF DC24A
DC24B
+24V 24G
(FG)DB SLD
DGDA
PW L RUN L ERR. 40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
COM
COMX8
X7
XA
X9
XC
XB
XE
XD XF
X0PW L RUN L ERR. 1
X0 X2 X4 X6
X1 X5X3
2 3 4 5 6 7 X8 9 A B C D E F
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB1-16D
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
39 40
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire324VDC
DC input
pts16 -wire124VDC
DC input
pts16 -wire124VDC
DC input
pts16 -wire324VDC
High speedinput
Output module
AJ65SBTB1-8T1
Output module
AJ65SBTB1-8T
Unit: mm
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
0.1mA or lower
None
AJ65SBTB1-8T AJ65SBTB1-8T1
Description
Screw T. block
Screw T. block
Input module
AJ65SBTB1-32D
Input module
AJ65SBTB1-32D1
Unit: mm
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
50mA or lower
(at 24VDC,with all points ON)
AJ65SBTB1-32D AJ65SBTB1-32D1
Description
Screw T. block
Screw T. block
DADBDGSLD
DC DC+24VFG24G
X0X1X2X3X4X5X6X7X8X9XAXBXCXDXEXFX10X11X12X13X14X15X16X17X18X19X1AX1BX1CX1DX1EX1FCOM
21
34567
98
1011121314151617181920212223242526272829303132333435363738394041 COM
R
R
R
R24VDC
Module power supply
Insulation
Unit: mm
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
0.1mA or lower
None
0.18
Output module
AJ65SBTB2-8T
DescriptionAJ65SBTB2-8T AJ65SBTB2-8T1
Unit: mm
Output module
AJ65SBTB1-16T1
Output module
AJ65SBTB1-16T
Screw T. block
Screw T. block
DADBDGSLD
DC DC+24VFG24G
Y0Y1Y2Y3Y4Y5Y6Y7Y8Y9YAYBYCYDYEYFCTL+COM-
L
L
CTL+
21
34567
98
10111213141516171819202122232425
2425 COM-
L
Module power supply
Insulation
Constantvoltagecircuit
Load power supply
When common power supplyis used for I/O and loads.
I/O Modulepower supply(External power supply)
Y8 YA YC YE CTL+
Y9
Y6
Y7
Y4
Y5
Y2
Y3
Y0
Y1 YB YD YF COM-
0.1mA or lower
None
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
I/O Module
power supply
(External power supply)
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Description
AJ65SBTB1-16T AJ65SBTB1-16T1
Screw T. block
Screw T. block
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
32 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
32 points/common (2) (terminal block single wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
45mA or lower
(at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500 VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.25
Approx. 5mA
15VAC/3mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
8 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10 ms or lower
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio : within 5%)
15mA (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common (terminal block single wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500 VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.14
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 3.6A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
30mA (TYP.24VDC/common)
Not including external load current
Zener diode
16 points/common (terminal block single wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.18
8 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
17.8mA (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common (terminal block 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
500VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.25
Module power supply
Load power supply
When I/O power & load power is supplied
I/O Modulepower supply(External power supply)
DADBDGSLD+24VFG24G
21
34567
Y0Y1Y2Y3Y4Y5Y6
98
1011121314
Y715CTL+16COM-17
L
L
Insulation
Constant voltage circuit
DC DC
Y0Y1Y2Y3Y4Y5Y6
98
1011121314
Y715CTL+16COM-17
L
L
Y0 Y2 Y4 Y6 CTL+
Y1 Y3 Y5 Y7 COM-
Y4 Y5 Y6 Y7 DC24V
COM
Y3
COM
Y2
COM
Y1
COM
Y0
COM COM COM COM DC24G
Module power supply
DC DC
DADBDGSLD+24VFG24G
21
34567
Insulation
Y0COMY1COMY2COMY3
98
1011121314
COMY4COMY5COMY6COM
1615
1718192021
Y7COMDC24VDC24G
22232425
L
Constant voltage circuit
I/O Modulepower supply
(External power supply)
Output module
AJ65SBTB2-8T1
X8 XA XC XE X10 X12X6X4X2X0 COM
COM
X1C X1EX1AX18X16X14
X9 XB XD XF X11 X13X7X5X3X1 X1D X1FX1BX19X17X15
COM-
CTL+Y8
Y7
YA
Y9
YC
YB
YE
YD YF
Y0 1
Y0 Y2 Y4 Y6
Y1 Y5Y3
2 3 4 5 6 7 Y8 9 A B C D E F
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB1-16T
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
PW L RUN L ERR.
DC24G
DC24VY4 Y5 Y6 Y7
Y0PW L RUNL ERR. 1
Y0 Y1 Y2 Y3
COM
2 3 4 5 6 7
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB2-8T
COM COM COM COM COM COM COM
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
AJ65SBTB1-32D
X0 1 2 3 4 5 6 7 X8 A B C D E9 F X10 12 1314 15 1611 17 X18 1A1B 1C1D1E19 1F
X2X0 X4 X6
X1 X3 X5 X7
X8
X9
X10
X11
XA
XB
XC
XD
XE
XF
X12 X14 X16 X18 X1A X1C X1E
X13 X15 X17 X19 X1B X1D X1F
COM
COM
+24V 24G
(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
+24V 24G(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB1-8T
COM-Y7Y5CTL+Y6Y4
Y3
5 764321Y0
Y1Y2Y0
450
16.5
40
87.3
78.3 +0.04 0 (Mounting pitch)
2-4.5x5.1 mounting hole(M4 mounting screw)
About 105˚
7.5
7.9
DIN rail center
41 42
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts32 -wire124VDC
DC input
pts32 -wire124VDC
Protection
-wire10.5A
-wire10.5A
Protection
-wire20.5A
-wire20.5A
Protection
-wire10.5A
-wire10.5A
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts16
Transistoroutput
pts16
High speedinput
Lowleakage
Lowleakage
Lowleakage
Unit: mm
None
Voltage
Current
Voltage
Current
Output specifications
Number of output pointsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ONOutput formProtective function
ResponsetimeI/O Module power supply(External power supply)
Surge suppressionWiring method for commonNo. of stations occupiedI/O modulepower supplyNoise immunity
Withstand voltage
Insulation resistance
Degree of protectionWeight (kg)
Output module
AJ65SBTB2-16T1
Screw T. blockOutput module
AJ65SBTB2-16T
Unit: mm
Output module
AJ65SBTB1-32T1
Output module
AJ65SBTB1-32T
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
0.1mA or lower
None
AJ65SBTB1-32T AJ65SBTB1-32T1
Description
Screw T. block
Screw T. block
Screw T. block
DescriptionAJ65SBTB2-16T AJ65SBTB2-16T1
Output module
AJ65SBTB1-8TE
Unit: mm
Screw T. block
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Description
Output module
AJ65SBTB1-16TE
Unit: mm
Screw T. block
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Description
OFF ON
ON OFF
OFF ON
ON OFF
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
16 pointsPhotocoupler12/24VDC10.2 to 26.4VDC (ripple ratio: within 5%)0.5 A/point, 3.6A/common1.0A 10ms or less0.25mA or lower0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5ASink typeProtection against overload, overvoltage and overheat0.5ms or less1.5ms or less (Resistive load)10.2 to 26.4VDC (ripple ratio: within 5%)24.2mA (TYP.24VDC/common)Not including external load currentZener diode16 points/common (terminal block 2 wire type)Assignment of 32 points/station (16 points used)20.4 to 26.4VDC (ripple ratio : within 5%)55mA or lower (at 24VDC, with all points ON)Tested by a DC type noise simulator of 500Vp-p, noise width 1µs and 25 to 60Hz frequency500VAC across all DC external terminals and ground for 1min500VDC across all DC external terminals and ground, 10M or higher by insulation resistance testerIP2X0.25
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 4.8A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink typeProtection against overload, overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
50mA or lower
(TYP.24VDC/common) Not including
external load current
Zener diode
32 points/common (terminal block single wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
65mA or lower (at 24VDC, with all points ON)Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals and ground,
10M or higher by insulation resistance tester
IP2X
0.25
16 points
Photocoupler
12/2VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
1.0A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Source type
Overload protection, overheat protection
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
30mA (TYP.24VDC/common)
Not including external load current
Zener diode
16 points/common (terminal block single wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
0.18
8 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 0.8A/common
1.0A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Source type
Overload protection, overheat protection
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
15mA (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common (terminal block single wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
0.14
Y4 Y5 Y6 Y7 Y8 Y9Y3Y2Y1Y0
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COMCOM
DC24V
DC24G
YE YFYDYCYBYA
Module power supply
DC DC
DADBDGSLD+24VFG24G
21
34567
Insulation
Y0COMY1COMY2COMY3
1011121314
COMY4COMY5COM
1615
171819
Y620COMY7COMY8COM
2221
232425
Y926COMYACOMYBCOM
2827
293031
YC32COMYDCOMYECOM
3433
353637
YF38COMDC24VDC24G
4039
41
89
L
Constant voltage circuit
I/O Modulepower supply
(External power supply)
Y8 YA YC YE Y10 Y12Y6Y4Y2Y0
Y1 Y3 Y5 Y7 Y9 YB YD YF Y11 Y13 Y15 Y17 Y19 Y1B Y1D Y1F
CTL+COM
-
Y1C Y1EY1AY18Y16Y14
DADBDGSLD
DC DC+24VFG24G
Y0Y1Y2Y3Y4Y5Y6Y7Y8Y9YAYBYCYDYEYFY10Y11Y12Y13Y14Y15Y16Y17Y18Y19Y1AY1BY1CY1DY1EY1FCTL+COM-
L
L
CTL+
21
34567
98
1011121314151617181920212223242526272829303132333435363738394041
4041 COM-
L
Module power supply
Insulation
Constantvoltagecircuit
Load power supply
When common power supplyis used for I/O and loads.
I/O Modulepower supply(External power supply)
DADBDGSLD+24VFG24G
Y0Y1Y2Y3Y4Y5Y6Y7
L
L
21
34567
98
1011121314151617
COM+1617 CTL-
L
DC DC
COM+CTL-
Module power supply
Insulation
I/O Modulepower supply
(External power supply)
Constant voltage circuit
Loadpowersupply
When common power supplyis used for I/O and loads.
DC DC
COM+2425 CTL-
L
DADBDGSLD+24VFG24G
Y0Y1Y2Y3Y4Y5Y6Y7Y8Y9YAYBYCYDYEYFCOM+CTL-
L
L
21
34567
98
10111213141516171819202122232425
Module power supply
Insulation
I/O Modulepower supply
(External power supply)
Constant voltage circuit
Loadpowersupply
When common power supplyis used for I/O and loads.
Y0 Y2 Y4 Y6 COM+
Y1 Y3 Y5 Y7 CTL-
Y8 YA YC YE COM+
Y9
Y6
Y7
Y4
Y5
Y2
Y3
Y0
Y1 YB YD YF CTL-
AJ65SBTB2-16T
Y0 1 2 3 4 5 6 7 Y8 A B C D E9 F
Y1Y0 Y2 Y3
COM
Y4 Y8Y5 Y6 Y7 Y9 YA YB YC YD YE YF DC24V
DC24G
+24V 24G(FG)DB SLD
DGDA
PW L RUN L ERR.4020 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
AJ65SBTB1-32T
Y0 1 2 3 4 5 6 7 Y8 A B C D E9 F Y10 12 13 14 15 1611 17 Y18 1A 1B 1C 1D 1E19 1F
Y2Y0 Y4 Y6Y1 Y3 Y5 Y7
Y8Y9
Y10Y11
YA
YBYC
YDYE
YFY12 Y14 Y16 Y18 Y1A Y1C Y1E
Y13 Y15 Y17 Y19 Y1B Y1D Y1F
CTL+
COM-
+24V 24G(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
+24V 24G(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB1-8TE
CTL-Y7Y5
COM+Y6Y4
Y3
5 764321Y0L ERR.L RUNPW
Y1
Y2Y0
450
16.5
40
87.3
78.3 +0.04 0 (Mounting pitch)
2-4.5x5.1 mounting hole(M4 mounting screw)
About 105˚
7.5
7.9
DIN rail center
PW L RUN L ERR Y0 1 2 3 4 5 6 7 Y8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTB1-16TE
ON
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
COMYFYDYBY9Y7Y5Y3Y1
Y6Y4Y2Y0 YEYCYAY8 COM24G
(FG)DB
DA +24V
SLD
DG
43 44
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Protection
-wire20.5A
-wire20.5A
Protection
-wire10.5A
-wire10.5A
Protection
-wire10.1A
Protection
-wire10.1A
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts32
Transistoroutput
pts32
Transistoroutput
pts16
Transistoroutput
pts8
Lowleakage
Lowleakage
Unit: mm
Unit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
External power
supply for time
Surge suppression
Wiring method for common
Number of stations occupied
I/O module
power supply
Noise durability
Withstand voltage
Insulation resistance
Protection of degree
Weight (kg)
Output module
AJ65SBTB1B-16TE1
Output module
AJ65SBTB1-32TE1
External dimensions & terminal layoutExternal device connection diagram
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Detailed specifications
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
External power
supply for time
Surge suppression
Wiring method for common
Number of stations occupied
I/O module
power supply
Noise durability
Withstand voltage
Insulation resistance
Protection of degree
Weight (kg)
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Unit: mm
Unit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage/
current
Minimum switching load
Maximum switching voltage
Response
time
Lifespan
Maximum switching frequency
Surge suppression
Common wiring method
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output specifications
Number of output points
Isolation method
Rated load voltage/
current
Minimum switching load
Maximum switching voltage
Response
time
Lifespan
Maximum switching frequency
Surge suppression
Common wiring method
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output module
AJ65SBTB2N-8RScrew T. block
Output module
AJ65SBTB2N-16RScrew T. block
External dimensions & terminal layoutExternal device connection diagram
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Detailed specifications
OFF ON
ON OFF
Mechanical
Electrical
Voltage
Current
OFF ON
ON OFF
Mechanical
Electrical
Voltage
Current
Screw T. block
-wire10.5A
Transistoroutput
pts16
Screw T. block
-wire10.5A
Transistoroutput
pts32
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio :within 5%)
0.5A/point 4A/common
1.0A 10ms or lower
0.1mA or lower
0.5V or lower (TYP) 0.5A
0.8V or lower (MAX) 0.5A
Source type
0.5ms or lower
1.5ms or lower (Resistive load)
10.2 to 26.4VDC (ripple ratio :within 5%)
10mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common
(terminal block single wire type)
1 station 32 points assignment (use 16 points)
20.4 to 26.4VDC (ripple ratio:within 5%)
45mA or lower (When 24VDC and all point is on)
DC type noise voltage 500Vp-p,
noise width 1µs, noise carrier frequency
25 to 60Hz (noise simulator condition)
500VAC for 1 minute between all
DC external terminals and ground
10M or higher measured with a 500VDC
insulation resistance tester
IP2X
0.26
Description
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio :within 5%)
0.5A/point 4.8A/common
1.0A 10ms or lower
0.1mA or lower
0.5V or lower (TYP) 0.5A
0.8V or lower (MAX) 0.5A
Source type
0.5ms or lower
1.5ms or lower (Resistive load)
10.2 to 26.4VDC (ripple ratio :within 5%)
15mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
32 points/common
(terminal block single wire type)
1 station 32 points assignment (use 32 points)
20.4 to 26.4VDC (ripple ratio:within 5%)
60mA or lower (When 24VDC and all point is on)
DC type noise voltage 500Vp-p,
noise width 1µs, noise carrier frequency
25 to 60Hz (noise simulator condition)
500VAC for 1 minute between all
DC external terminals and ground
10M or higher measured with a 500VDC
insulation resistance tester
IP2X
0.26
Description
16 points
Relay insulation
24VDC (resistive load),
240VAC (COS =1)/2/point, 8A/common
5VDC 1mA
264VAC 125VDC
10ms or less
12ms or less
20 million times or more
100,000 times or more under rated load
switching voltage/current
100,000 times or more at 200VAC,
1.5A or 240VAC, 1A (COS =0.7)
100,000 times or more at 200VAC,
1A or 240VAC, 0.5A (COS =0.35)
100,000 times or more at 24VDC,
1A or 100VDC, 0.1A (L/R=7ms)
3600 times/hour
None
16 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
120mA or lower (at 24VDC, with all points ON)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
2830VAC rms/3 cycles across AC external terminals
and ground (altitude 2000m), 500VAC for 1minute
across DC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across AC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across DC external terminals and ground
0.35
Description
8 points
Relay insulation
24VDC (resistive load),
240VAC (COS =1)/2A/1 point, 4A/common
5VDC 1mA
264VAC 125VDC
10ms or less
12ms or less
20 million times or more
100,000 times or more under rated load
switching voltage/current
100,000 times or more at 200VAC,
1.5A or 240VAC, 1A (COS =0.7)
100,000 times or more at 200VAC,
1A or 240VAC, 0.5A (COS =0.35)
100,000 times or more at 24VDC,
1A or 100VDC, 0.1A (L/R=7ms)
3600 times/hour
None
8 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
85mA or lower (at 24VDC, with all points ON)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
2830VAC rms/3 cycles across AC external terminals
and ground (altitude 2000m), 500VAC for 1 minute
across DC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across AC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across DC external terminals and ground
0.25
Y4 Y5 Y6 Y7 Y8 Y9Y3Y2Y1Y0
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMACOM
B
YE YFYDYCYBYA
Y4 Y5 Y6 Y7
COMB
Y3
COMB
Y2
COMB
Y1
COMB
Y0
COMB COMB COMB COMB COMB
COMA
L
L
98
1011121314
1615
1718192021
Y0COM BY1COM BY2COM BY3COM BY4COM BY5COM BY6COM BY7COM BCOM ACOM B
22232425
DADBDGSLD+24VFG24G
21
34567
Module power supply
Insulation
DC DC
100/200VAC
RA
Module power supply
DADBDGSLD+24VFG24G
21
34567
Insulation
COM B
Y0COM BY1COM BY2
Y3COM BY4COM BY5COM BY6COM BY7COM BY8COM BY9COM BYACOM BYBCOM BYCCOM BYDCOM BYECOM BYFCOM BCOM ACOM B
98
1011121314
1615
17181920
2221
23242526
2827
29303132
3433
35363738
4039
41
L
100/200VAC
L
DC DC
RA
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
COMBCOMBCOMBCOMBCOMBCOMBCOMBCOMB
AJ65SBTB2N-8R
COMB
Y3Y2Y1Y0 Y7Y6Y5Y4 COMA
6 754321Y0
24G
(FG)DB
DA +24V
SLD
DG
ON
4STATION NO.
1B RATE
12248102040
AJ65SBTB2N-16R
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
X0 1 2 3 4 5 6 7 Y8 A B C D E9 F
Y1Y0 Y2 Y3
COMB
Y4 Y8Y5 Y6 Y7 Y9 YA YB YC YD YE YF+24V 24G(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
(Mounting pich)
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMBCOMBCOMB
COMA
DIN rail center
(FG)
PW L RUNL ERR.Y0 1 2 3 4 5 6 7 Y8 A B C D E9 F
YF NC
NC
Y0 Y1 Y2 Y3 Y4 Y8Y5 Y6 Y7 Y9 YA YB YC YD YE+24V 24GDB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
CTL2- COM2+COM2-COM2-COM2-COM2-COM2-COM2-COM1+CTL1-COM1-COM1-COM1-COM1-COM1-COM1-
AJ65SBTB1B-16TE1
Y4 Y5 Y6 Y7 Y8 Y9Y3Y2Y1Y0
COM1-
COM1-
COM1-
COM1-
COM1-
COM1-
CTL1-
COM1+
COM2-
COM2-
COM2-
COM2-
COM2-
COM2-
CTL2-
COM2+
NC
NC
YE YFYDYCYBYA
Y8 YA YC YE Y10 Y12Y6Y4Y2Y0
Y1 Y3 Y5 Y7 Y9 YB YD YF Y11 Y13 Y15 Y17 Y19 Y1B Y1D Y1F
COM+CTL
-
Y1C Y1EY1AY18Y16Y14
2-4.5 x 5.1 Mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
(Mounting pitch)
(DIN rail center)
(FG)
PW L RUNL ERR.Y0 1 2 3 4 5 6 7 Y8 A B C D E9 F Y1011 12 13 14 15 16 17 Y18 1A1B1C1D1E19 1F
Y1E COM+
CTL-
Y0 Y2 Y4 Y6 Y8 Y10YA YC YE Y12 Y14 Y16 Y18 Y1A Y1C+24V 24GDB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
Y1D Y1FY1BY19Y17Y15Y13Y11YFYDYBY9Y7Y5Y3Y1
AJ65SBTB1B-16TE1
2-4.5 x 5.1 Mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
(Mounting pitch)
(DIN rail center)
I/O module power supply
DADBDGSLD+24VFG24G
234567
Insulation
Y0
Y1
Y2
Y3
Y4
Y5
Y6
98
1011121314
Y7
Y8
Y9
YA
YB
1615
171819
YC
20
YD
YE
YF
2221
232425
DC/DC
1
COM1-
LExternal power supply for output and load power supply are common.
26272829303132333435363738394041
COM1-
COM1-
COM1-
COM1-
COM1-
CTL1-
COM1+
COM2-
COM2-
COM2-
COM2-
COM2-
COM2-
CTL2-
NCCOM2+
NC
Constantvoltage circuit
L
External power supply for output and load power supply are common.
Constantvoltage circuitL
L
I/O module power supply
DADBDGSLD+24VFG24G
234567
Insulation
Y0Y1Y2Y3Y4Y5Y6
98
1011121314
Y7Y8Y9YAYB
1615
171819
YC20YDYEYFY10Y11
2221
232425
DC/DC
L
1
Y1226Y1327Y1428Y1529Y1630Y1731Y1832Y1933Y1A34Y1B35Y1C36Y1D37Y1E38Y1F39COM+40CTL-41Load power supply
COM+40CTL-41
When external power supply for output and load power supply are common.
External power supply for output
L
L
Constantvoltage circuit
About 105˚
About 105˚
45 46
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
-wire22A
-wire22A
Relayoutput
pts8
Relayoutput
pts16
Unit: mm
I/O composite module
AJ65SBTB32-8DT2
I/O composite module
AJ65SBTB32-8DT Screw T. block
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
4 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 1.2A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against
overload, overvoltage
and overheat
0.5ms or lower
1.5ms or lower (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
14.6mA (at 24VDC, with all points ON)
Not including external load current
Zener diode
8 points/common (terminal block 2-wire type)
Input specifications
Output specifications
Description
DescriptionAJ65SBTB32-8DT AJ65SBTB32-8DT2
0.1mA or lower
None
Screw T. block
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Unit: mm
Unit: mm
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Max. load voltage
Max. load current
Min. load voltage/current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Max. load voltage
Max. load current
Min. load voltage/current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output module
AJ65SBTB2N-8SScrew T. block
Output module
AJ65SBTB2N-16SScrew T. block
External dimensions & terminal layoutExternal device connection diagram
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
-wire20.6A
-wire20.6ATriac
output
pts16
Triacoutput
pts8
Description
8 points
Photocoupler
100 to 240VAC 50/60Hz±5%
264VAC
0.6A/point 2.4A/common
50VAC 100mA, 100VAC 10mA, 240VAC 10mA
25A 10ms or less
1.5mA rms or lower (100VAC rms 60Hz),
3mA rms or lower (200VAC rms 60Hz)
1.5V rms or lower (at 0.6A)
1ms or less
1/2 cycles + 1ms max.
C/R absorber (0.01µF+47 )
8 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
55mA or lower (at 24VDC, with all points ON)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
2830VAC rms/3 cycles across AC external terminals
and ground (altitude 2000m), 500VAC for 1 minute
across DC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across AC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across DC external terminals and ground
0.25
Description
16 points
Photocoupler
100 to 240VAC 50/60Hz±5%
264VAC
0.6A/point 4.8A/common
50VAC 100mA, 100VAC 10mA, 240VAC 10mA
25A 10ms or less
1.5mA rms or lower (100VAC rms 60Hz),
3mA rms or lower (200VAC rms 60Hz)
1.5V rms or lower (when 0.6A)
1ms or less
1/2 cycles + 1ms max.
C/R absorber (0.01µF+47 )
16 points/common (Terminal block 2-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
85mA or lower (at 24VDC, with all points ON)
Fast transient/burst noise created by a noise
simulator of 1500Vp-p, noise width 1µs and
25 to 60Hz frequency (IEC61000-4-4): 1kV
2830VAC rms/3 cycles across AC external terminals
and ground (altitude 2000m), 500VAC for 1 minute
across DC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across AC external terminals and ground
10M or higher by 500VDC insulation resistance
tester across DC external terminals and ground
0.35
4 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5 ms or less (at 24 VDC)
1.5 ms or less (at 24 VDC)
8 points/common (terminal block 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple rate : within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across DC external terminals
and ground for 1 minute
10M or higher across DC external terminals and
ground by a 500VDC insulation resistance tester
IP2X
0.18
Y8 Y9 YA YB
COM+
X3
COM-
X2
COM+
X1
COM-
X0
COM+
COM+
COM+
COM+
DC24G
DC24V
Constant voltage circuit
Module power supply
DC DC
DADBDGSLD+24VFG24G
21
34567
Insulation
X0COM+X1COM-X2COM+X3
98
1011121314
COM-Y8COM+Y9COM+YACOM+
1615
1718192021
YBCOM+DC24VDC24G
22232425
L
3-wiretypesensor
II/O Modulepower supply
(External power supply)
RR
DC24G
DC24VY8 Y9 YA YB
X0PW L RUN L ERR. 1
X0 X1 X2 X3
COM+
2 3 Y8 9 A B
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
AJ65SBTB32-8DT
COM- COM+ COM- COM+ COM+ COM+ COM+
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
Y4 Y5 Y6 Y7 Y8 Y9Y3Y2Y1Y0
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMACOM
B
YE YFYDYCYBYA
Y4 Y5 Y6 Y7
COMB
Y3
COMB
Y2
COMB
Y1
COMB
Y0
COMB COMB COMB COMB COMB
COMA
Module power supply
DC/DC
DADBDGSLD+24VFG24G
21
34567
Insulation
COM B
Y0COM BY1COM BY2
Y3COM BY4COM BY5COM BY6COM BY7COM BY8COM BY9COM BYACOM BYBCOM BYCCOM BYDCOM BYECOM BYFCOM BCOM ACOM B
98
1011121314
1615
17181920
2221
23242526
2827
29303132
3433
35363738
4039
41
L
100/200VAC
L
R
Triac
Surge suppression
L
98
1011121314
1615
171819
2021
Y0COM B
Y1COM BY2COM BY3COM BY4
COM BY5COM BY6COM BY7COM B
COM ACOM B
22232425
DA
DBDGSLD+24VFG24G
2
1
34567
Module power supply
Insulation
100/200VAC
DC DC
R
Triac
Surge suppression
L
AJ65SBTB2N-16S
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
Y0 1 2 3 4 5 6 7 Y8 A B C D E9 F
Y1Y0 Y2 Y3COMB
Y4 Y8Y5 Y6 Y7 Y9 YA YB YC YD YE YF+24V 24G(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
(Mounting pich)
COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMBCOMBCOMB
COMA
DIN rail center
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
COMBCOMBCOMBCOMBCOMBCOMBCOMBCOMB
AJ65SBTB2N-8S
COMB
Y3Y2Y1Y0 Y7Y6Y5Y4 COMA
6 754321Y0
24G
(FG)DB
DA +24V
SLD
DG
ON
4STATION NO.
1B RATE
12248102040
47 48
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts4 -wire324VDC Protection
-wire20.5A
DC input
pts4 -wire324VDC
-wire20.5A
Transistoroutput
pts4
Transistoroutput
pts4Low
leakage
Unit: mm
I/O composite module
AJ65SBTB32-16DT2
I/O composite module
AJ65SBTB32-16DT
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load
voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
8 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against
overload, overvoltage
and overheat
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
14.6mA or lower (at 24VDC, with all points ON)
Not including external load current
Zener diode
16 points/common (terminal block 2-wire type)
Input specifications
Output specifications
Description
DescriptionAJ65SBTB32-16DT AJ65SBTB32-16DT2
0.1mA or lower
None
Screw T. block
Screw T. block
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Unit: mm
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area external
power supply
Surge suppression
8 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio : within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against overload, overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio : within 5%)
17.8mA or less (at 24VDC, with all points ON) Not including external load current
Zener diode
I/O composite module
AJ65SBTB1-16DT1
I/O composite module
AJ65SBTB1-16DT2
I/O composite module
AJ65SBTB1-16DT3
I/O composite module
AJ65SBTB1-16DT
Input specifications
Output specifications
DescriptionAJ65SBTB1-16DT AJ65SBTB1-16DT1 AJ65SBTB1-16DT2 AJ65SBTB1-16DT3
DescriptionAJ65SBTB1-16DT AJ65SBTB1-16DT2
0.1mA or lower
None
AJ65SBTB1-16DT1 AJ65SBTB1-16DT3
Screw T. block
Screw T. block
Screw T. block
Screw T. block
External dimensions & terminal layout
External dimensions & terminal layoutDetailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
DC input
pts8 -wire124VDC Protection
-wire10.5A
DC input
pts8 -wire124VDC Protection
-wire10.5A
DC input
pts8 -wire124VDC
-wire10.5A
DC input
pts8 -wire124VDC
-wire10.5A
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Transistoroutput
pts8
Lowleakage
Lowleakage
High speedinput
High speedinput
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5 ms or less (at 24VDC)
1.5 ms or less (at 24VDC)
Positive common (Sink type)
16 points/common (terminal block single wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p, noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals and ground for 1min
10M or higher, between DC external terminals and ground by a 500VDC insulation resistance tester
IP2X
0.25
Approx. 5mA
15VAC/3.0mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2 ms or less (at 24VDC)
0.2 ms or less (at 24VDC)
Approx. 7mA
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5 ms or less (at 24VDC)
1.5 ms or less (at 24VDC)
Approx. 5mA
15VAC/3.0mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2 ms or less (at 24VDC)
0.2 ms or less (at 24VDC)
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common (Terminal block 3-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
IP2X
0.25
Module power supply
DC DC
DADBDGSLD+24VFG24G
21
34567
Insulation
X0COM+X1COM-X2COM+X3
1011121314
COM-X4COM+X5COM-
1615
171819
X620COM+X7COM-Y8COM+
2221
232425
Y926COM+YACOM+YBCOM+
2827
293031
YC32COM+YDCOM+YECOM+
3433
353637
YF38COM+DC24VDC24G
4039
41
89
RR
L
Constant V. circuit
II/O Modulepower supply
(External power supply)
3 wiretypesensor
X4 X5 X6 X7 Y8 Y9X3X2X1X0 DC24V
DC24G
YE YFYDYCYBYA
COM+
COM-
COM+
COM-
COM+
COM+
COM-
COM+
COM-
COM+
COM+
COM+
COM+
COM+
COM+
COM+
AJ65SBTB32-16DT
X0 1 2 3 4 5 6 7 Y8 A B C D E9 F
X1X0 X2 X3
COM+
X4 Y8X5 X6 X7 Y9 YA YB YC YD YE YF DC24A
DC24B
+24V 24G
(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
COM- COM+ COM- COM+ COM- COM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
Constant voltagecircuit
RR
I/O Module power supply(External power supply)
Module power supply
DADBDGSLD+24VFG24G
21
34567
Insulation
X0X1X2X3X4X5X6
98
1011121314
X7Y8Y9YAYBYCYD
1615
1718192021
YEYF
2223
L
COM+COM-
2425
DC DC
Load voltage
COM+2425 CTL-
L When common power supplyis used for I/O and loads.
Y8 YA YC YE
Y9
X6
X7
X4
X5
X2
X3
X0
X1 YB YD YF COM-
COM+
COM-
COM+Y8 YA YC YE
X0PW L RUN L ERR. 1
X0 X1 X4 X6
X1
2 3 Y8 9 A B
+24V 24G
(FG)DB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
Y8 9 A B C D E F
AJ65SBTB1-16DT
X3 X5 X7 Y9 YB YD YF
DIN rail center
118
2-4.5x5.1 mounting hole(M4 mounting screw)
109 +10
450
16.5
40
About 105˚
7.5
7.9
(Mounting pitch)
49 50
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire324VDC Protection
-wire20.5A
DC input
pts8 -wire324VDC
-wire20.5A
Transistoroutput
pts8
Transistoroutput
pts8Low
leakage
Unit: mm
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
16 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
Protection against overload, overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
30mA or lower
(24 VDC/common)
Not including external
load current
Zener diode
I/O composite module
AJ65SBTB1-32DT1
I/O composite module
AJ65SBTB1-32DT2
I/O composite module
AJ65SBTB1-32DT3
I/O composite module
AJ65SBTB1-32DT
Input specifications
Output specifications
DescriptionAJ65SBTB1-32DT AJ65SBTB1-32DT1 AJ65SBTB1-32DT2 AJ65SBTB1-32DT3
DescriptionAJ65SBTB1-32DT AJ65SBTB1-32DT2
0.1mA or lower
None
30mA or lower
(24VDC/common)
Not including external
load current
AJ65SBTB1-32DT1
24.2mA or lower
(at 24VDC, with all point ON)
Not including external
load current
AJ65SBTB1-32DT3
24.2mA or lower
(at 24VDC, with all point ON)
Not including external
load current
Screw T. block
Screw T. block
Screw T. block
Screw T. block
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layout
Detailed specifications
External device connection diagram
Unit: mm
I/O composite module
AJ65SBTB1-32DTE1
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Degree of protection
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load
voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
16 points
Photocoupler
24VDC
19.2 to 26.4VDC
(ripple ratio: within 5%)
0.5A/point, 3.6A/common
1.0A 10ms or less
0.1mA or lower
0.5V or lower (TYP) 0.5A
0.8V or lower (MAX) 0.5A
Source type
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
10mA or lower (TYP. 24VDC/common) Not
including external load current
Zener diode
32 points/common (terminal block 1-wire type)
Input specifications
Output specifications
Description
Description
Screw T. block
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
DC input
pts16 -wire124VDC
-wire10.5ATransistor
output
pts16
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
32 points/common (terminal block single wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
60mA or lower (at 24VDC, with all points ON), not including external load current
Tested by a DC type noise simulator of 500Vp-p, noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals and ground for 1 min
10M or higher, between DC external terminals and ground by a 500VDC insulation resistance tester
IP2X
0.25
Approx. 5mA
15VAC/3.0mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
Approx. 7mA
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Approx. 5mA
15VAC/3.0mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Negative common (Source type)
32 points/common (Terminal block 1-wire type)
1 station 32 points assignment (32 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
50mA or lower (at 24VDC, with all points ON)
DC type noise voltage 500Vp-p
noise width 1µs, noise carrier frequency 25
to 60Hz (noise simulator condition)
500VAC for 1 minute between all DC external
terminals and ground
10M or higher, measured with a 500VDC
isulation resistance tester
IP2X
0.26
DADBDGSLD
DC DC+24VFG24G
X0X1X2X3X4X5X6X7X8X9XAXBXCXDXEXFY10
21
34567
98
10111213141516171819202122232425 Y11
R
R
Y12Y13Y14Y15Y16
262728293031 Y17
Y18Y19Y1AY1B
3233343536 Y1C
Y1DY1EY1FCOM+
3738394041 COM-
L
Module power supply
Insulation
I/O Module power supply(External power supply)
Constant V. circuit
Load voltage
COM+4041 CTL-
L When common power supplyis used for I/O and loads.
X8 XA XC XE X10 X12X6X4X2X0 COM+COM
-
X1C X1EX1AX18X16X14
X9 XB XD XF X11 X13X7X5X3X1 X1D X1FX1BX19X17X15
AJ65SBTB1-32DT
X0 1 2 3 4 5 6 7 X8 A B C D E9 F Y10 12 13 14 15 1611 17 Y18 1A1B 1C1D 1E19 1F
X2X0 X4 X6
X1 X3 X5 X7
X8
X9
Y10
Y11
XA
XB
XC
XD
XE
XF
Y12 Y14 Y16 Y18 Y1A Y1C Y1E
Y13 Y15 Y17 Y19 Y1B Y1D Y1F
COM+
COM-
+24V 24G
(FG)DB SLD
DGDA
PW L RUN L ERR.40 20 10 8 4 2 2 1
B RATE1
STATION NO.4
ON
2-4.5x5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
About 105˚
(Mounting pich)
DIN rail center
About 105˚
X8 XA XC XE Y10 Y12X6X4X2X0
X1 X3 X5 X7 X9 XB XD XF Y11 Y13 Y15 Y17 Y19 Y1B Y1D Y1F
COM+
CTL-
Y1C Y1EY1AY18Y16Y14
(FG)
PW L RUNL ERR.X0 1 2 3 4 5 6 7 X8 A B C D E9 F Y1011 12 13 14 15 16 17 Y18 1A1B1C1D1E19 1F
Y1E COM+
CTL-
X0 X2 X4 X6 X8 Y10XA XC XE Y12 Y14 Y16 Y18 Y1A Y1C+24V 24GDB SLD
DGDA
40 20 10 8 4 2 2 1B RATE
1STATION NO.
4
ON
Y1D Y1FY1BY19Y17Y15Y13Y11XFXDXBX9X7X5X3X1
AJ65SBTB1B-32DTE1
2-4.5 x 5.1 mounting hole (M4 mounting screw)
89
170+10
179
4050
4
16.5
7.5
7.9
(Mounting pich)
DIN rail center
I/O module power supply
DADBDGSLD+24VFG24G
234567
Insulation
X0X1X2X3X4X5X6
98
1011121314
X7X8X9XAXB
1615
171819
XC20XDXEXFY10Y11
2221
232425
DC/DC
1
Y1226Y1327Y1428Y1529Y1630Y1731Y1832Y1933Y1A34Y1B35Y1C36Y1D37Y1E38Y1F39COM+40COM-41
Load power supply
External power supplyfor output
COM+40COM-41
When external power supply for output and load power supply are common.
L
Constantvoltage circuit
L
51 52
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts16 -wire124VDC Protection
-wire10.5A
DC
16 1 10.5ADC input
pts16 -wire124VDC Protection
-wire10.5A
DC input
pts16 -wire124VDC
-wire10.5A
DC input
pts16 -wire124VDC
-wire10.5A
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
High speedinput
High speedinput
Screw/2-piece terminal block type
Overview
Part names and functions
Features
Screw/2-piece terminal block typeScrew T. block
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65BTB2-16DUnit: mm
Screw T. block+COM
-COM
* The actual modules may slightly differ in shapes from the photos shown.
The I/O terminal block is removable.The modules are mountable in 6 different orientations.The 2-piece structure allows easy servicing such asmodule replacement without rewiring.
External dimensions & terminal layoutExternal device connection diagram
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
Description
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 28.8VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
10ms or less
10ms or less
16 points/common
(terminal block single wire type)
Positive/Negative common shared type
(Sink/source shared type)
1 station
15.6 to 28.8VDC (ripple ratio : within 5%)
60mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC insulation
resistance tester resistance tester
0.32
Description
16 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 28.8VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
10ms or less
10ms or less
16 points/common (terminal block 2-wire type)
Positive/Negative common shared type
(Sink/source shared type)
1 station
15.6 to 28.8VDC (ripple ratio: within 5%)
60mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC insulation
resistance tester resistance tester
0.4
LED indication
PWL RUN
L ERR
X0 to 1F
LED name DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.ON: Communication errorFlashing at regular intervals:
The station No. and/or transmission rate switch setting has been changed while the power is on.
Flashing irregularly:The terminating resistor setting is incorrect, or the module and CC-Link dedicated cables are being affected by noise.
OFF: Communication is normal.Indicates the input ON/OFF status.Turns ON and OFF when the input is ON or OFF respectively.
Transmission rate setting switch
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Settingvalue Transmission rate
DIN rail mounting hookThis hook is used to mount the module on the DIN rail.
Terminal block
Input module
AJ65BTB1-16D
Unit: mm
Screw T. block+COM
-COM
DA DG
DB SLD
(FG)
1 3 5 7 9 11 13 15 17 19 21 23 25 27
2 4 6 8 10 12 14 16 18 20 22 24 26
+24V 24G
STATION NO.X10 X1
MITSUBISHI
5
0 1
46
23
5
0 1
46
9237
8
0 1
4
23
AJ65BTB1-16D B RATE
0
PW
1 2 3 4 5 6 7 8 9 A B C D E F
L RUN SD RD L ERR.
DADBDGSLD+24VFG24GX0X1X2X3X4X5X6X7COMNCX8X9XAXBXCXDXEXFCOMNC
DC DC
Insulation
R
R
R
R
123456789101112131415161718192021222324252627
24VDC
24VDC
DADBDGSLD+24VFG24GNCNCX0COMBX1X2COMBX3X4COMBX5X6COMBX7NCNCX8COMBX9XA
DC/DC
R
R
R
R
123456789101112131415161718192021222324252627
COMB28XB29XC30COMB31XD32XE33COMB34XF35COMA36COMB37
24VDC
24VDC
X6
NCCOMB
NCX7
X8 X9X1
NC COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMB
COMA
XE XF
XDXC
XBXA
X0
X2 X3
DB
+24V
NC
24G
SLD FG
DGDA
MITSUBISHI AJ65BTB1-16D0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
9.5
46
56
65
142.9
151.9
9.5
46
56
65
188.4
197.4
MITSUBISHI AJ65BTB2-16T0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
COM
X1 X3 X5 X7
X2
24G
X0
+24V
FG
DG
SLD
DA
DB X4 X6 COM
NC
X8
X9 XB
XA
XD
XC
XF
XE
NC
X4 X5
Terminal block can be removed.
Station No. setting switchSet the 10s place using the "X10" switch.Set the 1s place using the "X1" switch.Make sure that the setting is within the range of 1 to 64.
2- 4.5 mounting hole
2- 4.5 mounting hole
53 54
Remote I/O moduleRemote I/O modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts16 -wire124VDC
DC input
pts16 -wire224VDC
Output module
AJ65BTB2-16R
Unit: mm
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Voltage
Current
Output module
AJ65BTB2-16TUnit: mm
Output module
AJ65BTB1-16T
Unit: mm
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage/current
Minimum switching load
Maximum switching voltage
Response
time
Life
Maximum switching frequency
Output area
external
power supply
Surge suppression
Common wiring method
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Voltage
Current
Voltage
Current
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Voltage
Current
Screw T. block Screw T. block
Screw T. block
External dimensions & terminal layoutExternal device connection diagram
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
Mechanical
Electrical
OFF ON
ON OFF
Description
16 points
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.5 A/point, 4A/common
(Ta=45°C) 218A/common (Ta=55°C)
4A 10ms or lower
0.1mA or lower
0.9V or lower (TYP) 0.5A, 1.5V or
lower (MAX) 0.5A
Sink type
2ms or less
2ms or less (Resistive load)
10.2 to 28.8VDC (ripple ratio: within 5%)
100mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common (terminal block single wire type)
1 station
15.6 to 28.8VDC (ripple ratio: within 5%)
80mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC insulation
resistance tester resistance tester
0.34
Description
16 points
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
4A 10ms or less
0.1mA or lower
0.9V or lower (TYP) 0.5A, 1.5V or
lower (MAX) 0.5A
Sink type
2ms or less
2ms or less (Resistive load)
10.2 to 28.8VDC (ripple ratio: within 5%)
100 mA or lower (TYP.24 VDC/common)
Not including external load current
Zener diode
8 points/common (terminal block 2-wire type)
1 station
15.6 to 28.8VDC (ripple ratio: within 5%)
80mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC insulation
resistance tester resistance tester
0.41
Description
16 points
Photocoupler
24VDC (resistive load) 2A/Point,
240VAC (COS =1) 8A/common
5VDC 1mA
250VAC 110VDC
10ms or less
12ms or less
2million times or more
100,000 times or more under rated load
switching voltage/current
100,000 times or more at 200VAC,
1.5A or 240VAC, 1A (COS =0.7)
100,000 times or more at 200VAC,
1A or 240VAC, 0.5A (COS =0.35)
100,000 times or more at 24VDC,
1A or 100VDC, 0.1A (L/R=7ms)
3600 times/hour
24VDC ± 10% (ripple ratio : 4Vp-p or less)
90mA or lower
(at TYP.24 VDC, with all points ON)
None
8 points/common (Terminal block 2-wire type)
1 station
15.6 to 28.8VDC (ripple ratio: within 5%)
85mA or lower (at TYP.24 VDC)
Tested by a noise simulator of AC type
1500Vp-p or DC type 500Vp-p, noise
width 1µs and 25 to 60Hz frequency
500 VAC across all AC external terminals
and ground for 1 min
500 VAC across all DC external terminals
and ground for 1 min
500 VDC across all AC/DC external
terminals and ground,10M or higher by
insulation resistance tester
0.47
COM2-
Y1 Y3 Y5 Y7
Y2
24G
Y0
+24V
FG
DG
SLD
DA
DB Y4 Y6 COM1+
CTL1+
Y8
Y9 YB
YA
YD
YC
YF
YE
CTL2+
MITSUBISHI AJ65BTB1-16D0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
9.5
46
56
65
142.9
151.9
9.5
46
56
65
188.4
197.4
MITSUBISHI AJ65BTB2-16T0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
DADBDGSLD+24VFG24GY0Y1Y2Y3Y4Y5Y6Y7COM1+CTL1-Y8Y9YAYBYCYDYEYFCOM2-CTL2+
123456789
101112131415161718192021222324252627
L
DC/DC
R
RL
24VDC
12/24VDC
12/24VDC
DADBDGSLD+24VFG24GNCNCY0COM1+Y1Y2COM1+Y3Y4COM1+Y5Y6COM1+Y7COM1-COM1+Y8COM2+Y9YACOM2+YBYCCOM2+YDYECOM2+YFCOM2-COM2+
123456789
10111213141516171819202122232425262728293031323334353637
L
DC/DC
L
R
R
R
R
24VDC
12/24VDC
12/24VDC
DADBDGSLD+24VFG24GCTLGCTL+Y0COMBY1Y2COMBY3Y4COMBY5Y6COMBY7COMACOMBY8COMDY9YACOMDYBYCCOMDYDYECOMDYFCOMCCOMD
12345678910111213141516171819202122232425262728293031323334353637
L
DC/DC
L RA
RA
24VDC
24VDC
240VAC
240VAC
Y6
COM1-
COM1+
COM1+
Y7
Y8 Y9Y1
NC COM1+
COM1+
COM1+
COM2+
COM2+
COM2+
COM2+
COM2+
COM2-
YE YF
YDYC
YBYA
Y0
Y2 Y3
DB
+24V
NC
24G
SLD FG
DGDA
Y4 Y5
9.5
46
56
65
188.4
197.4
MITSUBISHI AJ65BTB2-16R0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
Y6
COM1-
COM1+
COM1+
Y7
Y8 Y9Y1
NC COM1+
COM1+
COM1+
COM2+
COM2+
COM2+
COM2+
COM2+
COM2-
YE YF
YDYC
YBYA
Y0
Y2 Y3
DB
+24V
NC
24G
SLD FG
DGDA
Y4 Y5
2- 4.5 mounting hole
2- 4.5 mounting hole
2- 4.5 mounting hole
55 56
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
-wire10.5A
-wire20.5A
-wire22.0ATransistor
output
pts16
Transistoroutput
pts16
Relayoutput
pts16
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
I/O composite module
AJ65BTB2-16DRUnit: mm
Voltage
Current
AJ65BTB2-16DR
Number of output points
Isolation method
Rated load
voltage/current
Minimum switching load
Maximum switching voltage
Response
time
Lifespan
Maximum switching frequency
Output area
external
power supply
Surge suppression
Wiring method for common
Screw T. block
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
Number of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
I/O composite module
AJ65BTB1-16DTUnit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
Description
8 points
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
4A 10ms or less
0.1mA or lower
0.9VDC or lower (TYP) 0.5A,
1.5VDC or lower (TYP) 0.5A
Sink type
2ms or less
2ms or less (Resistive load)
10.2 to 28.8VDC (ripple ratio: within 5%)
50 mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common
Output specifications
AJ65BTB2-16DT
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
Description
8 points
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
4A 10ms or less
0.1mA or lower
0.9VDC or lower (TYP) 0.5A,
1.5VDC or lower (TYP) 0.5A
Sink type
2ms or less
2ms or less (Resistive load)
10.2 to 28.8VDC (ripple ratio: within 5%)
50mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
8 points/common
Screw T. block I/O composite module
AJ65BTB2-16DTScrew T. block
AJ65BTB2-16DT
AJ65BTB2-16DR
AJ65BTB2-16DT
AJ65BTB2-16DR
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
OFF ON
ON OFF
Mechanical
Electrical
OFF ON
ON OFF
Voltage
Current
8 points
Photocoupler
24VDC (resistive load), 2A/1 point,
240VAC (COS =1), 8/common
5VDC 1mA
250VAC 110VDC
10ms or less
12ms or less
20million times or more
100,000 times or more under rated load
switching voltage/current
100,000 times or more at 200VAC,
1.5A or 240VAC, 1A (COS =0.7)
100,000 times or more at 200VAC,
1A or 240VAC, 0.5A (COS =0.35)
100,000 times or more at 24VDC,
1A or 100VDC, 0.1A (L/R=7ms)
3600 times/hour
24VDC ±10% (ripple ratio: 4Vp-p or less)
45mA or lower
(at TYP.24VDC, with all points ON)
None
8 points/1 common
Description
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 28.8VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
10ms or less
10ms or less
8 points/common (Terminal block 2-wire type)
Positive common (Sink type)
1 station
15.6 to 28.8VDC (ripple ratio : within 5%)
70mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator
of 500Vp-p, noise width 1µs and 25
to 60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.33
Description
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 28.8VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 3.3k
10ms or less
10ms or less
8 points/1 common (Terminal block 2-wire type)
Positive common (Sink type)
1 station
15.6 to 28.8VDC (ripple ratio: within 5%)
70mA or lower (at TYP.24VDC)
Tested by a DC type noise simulator
of 500Vp-p, noise width 1µs and 25
to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
500VDC across all DC external terminals
and ground, 10M or higher by insulation
resistance tester
0.41
NC
X1
X2 X3
X4 X5
X6 X7
Y8 Y9 YC
YA YB+24GDGDA
SLD
24G
X0
COM1COM
1-COM1
-COM1
-COM1
+
COM1-
COM2+
COM2+
YD
YFYECOM2+
COM2+
COM2-
COM2+
DB FG NC
CTL+
X1
X2 X3
X4 X5
X6 X7
Y8 Y9 YC
YA YB+24GDGDA
SLD
24G
X0
COMB
COMB
COMB
COMB
COMA
COMB
COMD
COMD
YD
YFYECOMD
COMD
COMC
COMD
DB FG CTLG
9.5
46
56
65
188.4
197.4
MITSUBISHI AJ65BTB2-16DT0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
COM2-
X1 X3 X5 X7
X2
24G
X0
+24V
FG
DG
SLD
DA
DB X4 X6 COM1+
NC
Y8
Y9 YB
YA
YD
YC
YF
YE
CTL2+
MITSUBISHI AJ65BTB1-16DT0 1
23
4
0 123
456
0 123
45678
9X10 X1
STATION NO.
B RATE
PW L RUN SD RD L ERR.
0 1 2 3 4 5 6 7 8 9 A B C D E F
9.5
46
56
65
142.9
151.9
DADBDGSLD+24VFG24GX0X1X2X3X4X5X6X7COM1+NCY8Y9YAYBYCYDYEYFCOM2-CTL2+
DC/DC
R
R
123456789101112131415161718192021222324252627
RL
24VDC
24VDC
12/24VDC
DADBDGSLD+24VFG24GNCNCX0COM1-X1X2COM1-X3X4COM1-X5X6COM1-X7COM1+COM1-Y8COM2+Y9YACOM2+YBYCCOM2+YDYECOM2+YFCOM2-COM2+
DC/DC
R
R
123456789
10111213141516171819202122232425262728293031323334353637
RL
24VDC
24VDC
12/24VDC
DADBDGSLD+24VFG24GCTLGCTL+X0COMBX1X2COMBX3X4COMBX5X6COMBX7COMACOMBY8COMDY9YACOMDYBYCCOMDYDYECOMDYFCOMCCOMD
DC/DC
R
R
123456789
10111213141516171819202122232425262728293031323334353637
LRA
24VDC
24VDC
24VDC
240VAC
2- 4.5 mounting hole
2- 4.5 mounting hole
57 58
Remote I/O modulesProduct information
Screw terminal block typeScrew T. block
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire224VDC
-wire20.5A DC input
pts8 -wire224VDC
-wire20.5A
DC input
pts8 -wire224VDC
-wire22.0A
Transistoroutput
pts8Transistor
output
pts8
Relayoutput
pts8
Spring clamp terminal block type
Overview The module can be mounted in 6 different orientations.
Features
Spring clamp terminal block typeSpring clamp
Voltage
Current
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise durability
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65VBTS3-16D
Unit: mm
Spring clamp
Refer to the derating curve on the left for input derating input points of the orientations other than Front mounting (Basic orientation).
Part names and functions
* The actual modules may slightly differ in shapes from the photos shown.
No screw tightening and retightening are needed, reducing wiring time.The 2-piece structure allows easy servcing such as module replacement without rewiring.DIN rail mounting or screw mounting is selectable.The modules are mountable in 6 different orientations.3-wire type sensor input is available.
Mounting orientation in which max. simultaneous input is not limited.
Mounting orientation max. simultaneous input is limited
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/75%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common
(Spring clamp terminal block 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC for 1minute between all DC
external terminals and ground
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.24
LED indication
PWL RUN
L ERR
X0 to 1F
LED name DescriptionON: Power ON OFF: Power OFFON: When communication is normal.OFF: When communication is interrupted (timeout error)ON: Communication errorFlashing at regular intervals: The station No. and/or
transmission rate switch setting has been changed while the power is on.
Flashing irregularly: The terminating resistor setting is incorrect, or the module and CC-Link dedicated cables are being affected by noise.
ON: Input is ON, OFF: Input is OFF
Set the 10s place using "10", "20" and/or "40" of STATION NO.Set the 1s place using "1", "2", "4" and/or "8" of STATION NO.Make sure that the setting is within the range of 1 to 64.
Transmission rate setting switch
Station No. setting switch
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Settingvalue 4
OFFOFFOFFOFFON
Transmissionrate
DIN rail mounting hookThis hook is used to mount themodule on the DIN rail.
Push-in communication connectorPush-in connector for communication line connection.
Mounting bracketThis removable fitting is used to mount the module to a panel.
Terminal block
4.5
137
5012
151±0.5
26±0
.3
51.5
23
2-M4 mounting screw hole
16.531
31.5
5
4
15.5
64±0
.3
106±0.55.0 13
.513
.5
13.5 13.5
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON CBA
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPW
D
ON
COM-COM-
COM+COM+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XFNC
AJ65VBTS3-16D
42
DIN rail center
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON CBA
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPW
D
ON
COM-COM-
COM+COM+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XFNC
AJ65VBTS3-16D
Pin No.12345
Signal Name
2OFFOFFONONOFF
Setting switch status
1OFFONOFFONOFF
LINKCABLE(IN)
12345
CON A
LINKCABLE(OUT)
DADBDG
SLD
CON B
CON CFG+24V(UNIT)24G(UNIT)
UNIT POWER CABLE(IN)+-
+-
DC DC
TB 1ATB 1B COM+TB 1C COM-TB 2ATB 2BTB 2CTB 3A
X0
TB 3B
COM+
TB 3C
COM-
TB 4A
X1
TB 4B
COM+
TB 4C
COM-
TB 5A
X2
TB 5B
COM+
TB 5C
COM-X3
COM+COM-
TB 16ATB 16BTB 16CTB 17A
XE
TB 17B
COM+
TB 17C
COM-XF
COM+COM-
CON DUNIT POWER CABLE(OUT)
12345
DADBDGVacancy
Vacancy
SLD
12345
VacancyVacancy
+24V(UNIT)24G(UNIT)VacancyVacancy
12345
Vacancy
Push-in connectorfor communication
Push-in connector for power supply & FG
Input area external power supply
3 wire sensor(Sink output)
Detectioncircuit
Detectioncircuit
2 wire sensor (Sink output)
2 wire sensor(Sink output)
Insulation
Terminal block
FG
4
123
5
4
123
5
4
123
5
4
123
5
[%]
[%]
100
75
50
0 10 20 30 40 50 55 [°C]
Ambient temperature [°C]
Derating curve
Terminal block can beremoved.
COM-COM-
COM+COM+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XFNC
DADBDGNCSLD
Power supply / FG connectorPush-in connector for module's power supplyline and FG connections.
Pin No.12345
Signal NameFG
+24V (UNIT)24G (UNIT)
NCNC
See page 59 for the pin-out of the push-in communication connector, and the power supply & FG connector.
CD
AJ65VBTS3-16D
Front mounting (Basic orientation)
Front mounting (Reverse orientation) Front mounting (Vertical orientation)
Ceiling mounting Flat surface mounting
Applicable modelsAJ65VBTS3-16D, AJ65VBTS3-32D, AJ65VBTS32-32DT(Refer to the derating curve)
59 60
Remote I/O modulesRemote I/O modulesProduct information
CONA
CONB
12345
CONC
COND
12345
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Con
nect
or p
in N
o.
Con
nect
or p
in N
o.
Max
. sim
ulta
neou
sin
put p
oint
s
DC input
points16 -wire324VDC
Output module
AJ65VBTS2-32TUnit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output module
AJ65VBTS2-16T
Unit: mm
Spring clamp
Spring clamp
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65VBTS3-32DUnit: mm
Spring clamp
Refer to the derating curve on the left for the max. input derating points of the orientations other than Front mounting (Basic orientation).
LINKCABLE(IN)
12345
CON A
LINKCABLE(OUT)
DADBDG
SLD
CON B
CON CFG+24V(UNIT)24G(UNIT)
UNIT POWER CABLE(IN)+-
DC DC
TB 1ATB 1B COM1+TB 1C COM1-TB 2ATB 2BTB 2CTB 3A
X0
TB 3B
COM1+
TB 3C
COM1-
TB 4A
X1
TB 4B
COM1+
TB 4C
COM1-
TB 15A
X2
TB 15B
COM1+
TB 15C
COM1-
XDCOM1+COM1-
TB 16ATB 16BTB 16CTB 17A
XE
TB 17B
COM1+
TB 17C
COM1-XF
COM1+COM1-
CON DUNIT POWER CABLE(OUT)
12345
DADBDGVacancy
Vacancy
SLD
12345
VacancyVacancy
+24V(UNIT)24G(UNIT)VacancyVacancy
12345
Vacancy
Push-in connectorfor communication
Push-in connector for power supply and FG
Input area external power supply
3 wire type sensor(Sink output)
2 wire type sensor(Sink output)
2 wire type sensor(Sink output)
3 wire type sensor(Sink output)
2 wire type sensor(Sink output)
2 wire type sensor(Sink output)
Detectioncircuit
Detectioncircuit
Insulation
Terminal block
FG
TB 18ATB 18B COM2+TB 18C COM2-TB 19ATB 19BTB 19CTB 20A
X0
TB 20B
COM2+
TB 20C
COM2-
TB 21A
X1
TB 21B
COM2+
TB 21C
COM2-
TB 33A
X2
TB 33B
COM2+
TB 33C
COM2-
X1ECOM2+COM2-
TB 34ATB 34BTB 34C
X1FCOM2+COM2-
VacancyInput area external power supply
Detectioncircuit
Detectioncircuit
4
123
5
4
123
5
4
123
5
4
123
5
COM2-COM1-
NC
COM2-
NC
COM1-
COM2+
CON
COM2+
CBA D
COM1+ COM1+
AJ65VBTS3-32D
236
222
23
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPW
ON
13.513.5
26 5012
42
51.5 4
DIN rail center
16.531
31.5
2-M4 mounting hole
5
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
[%]100
7569
11pts/common50
0 10 20 30 40 50 55 [˚C]
Ambient temperature [°C]
Derating curve
COM2-COM1-
NC
COM2-
NC
COM1-
COM2+ COM2+COM1+ COM1+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1BX1CX1DX1E X1F
See page 59 for the pin-out of the push-in communication connector, the powersupply and FG connector.
[%]
Max
. sim
ulta
neou
sin
put p
oint
s
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Description
32 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/69%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common
(spring clamp terminal block 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.41
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
1.0A 10ms or less
0.1mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
None
1ms or less
1ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
30mA or lower (at 24VDC with all point is ON)
Not including external load current
Zener diode
16 points/common
(spring clamp terminal block 2-wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.24
Description
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
1.0A 10ms or less
0.1mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (MAX) 0.5A
Sink type
None
1ms or less
1ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
30mA (at 24VDC, with all point ON)
Not including external load current
Zener diode
16 points/common
(spring clamp terminal block 2-wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4 VDC (ripple rate : within 5 %)
60mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.4
4.5
137
5012
151±0.5
26±0
.3
51.5
23
2-M4 mounting hole
16.531
31.5
5
4
15.5
64±0
.3
106±0.55.0 13
.513
.5
13.5 13.5
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON CBA
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPW
D
ON
NCCOM-
COM+COM+
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YFNC
AJ65VBTS3-16T
42
DIN rail center
COM2-COM1-
NC
COM2-
NC
COM1-
COM2+
CON
COM2+
CBA D
COM1+ COM1+
AJ65VBTS3-32T
236
222
23
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPWON
13.513.5
26 5012
42
51.5 4
DIN rail center
16.531
31.5
2-M4 mounting hole
5
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
Push-in connectorfor communication
VacancyCOM+COM-
Y0COM+Vacancy
Y1COM+Vacancy
Y2COM+Vacancy
YDCOM+Vacancy
YECOM+Vacancy
YFCOM+Vacancy
Output area external power supply
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG4 Vacancy5 SLD
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
CON B
12345
CON C
+24V(UNIT)24G(UNIT)
VacancyVacancy
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON D
FG+24V(UNIT)24G(UNIT)
VacancyVacancy
UNIT POWER CABLE(OUT)
TB 1ATB 1BTB 1CTB 2ATB 2BTB 2CTB 3ATB 3BTB 3CTB 4ATB 4BTB 4C
TB 15ATB 15BTB 15CTB 16ATB 16BTB 16CTB 17ATB 17BTB 17C
Insulation
Push-in connector for power supply and FG
Constant v.circuit
FG
Terminal block
12345
12345
12345
12345
VacancyCOM2+COM2-
Y10COM2+Vacancy
Y11COM2+Vacancy
Y12COM2+Vacancy
Y1DCOM2+Vacancy
Y1ECOM2+Vacancy
Y1FCOM2+Vacancy
VacancyCOM1+COM1-
Y0COM1+Vacancy
Y1COM1+Vacancy
Y2COM1+
COM1+Vacancy
YECOM1+Vacancy
YFCOM1+Vacancy
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG4 Vacancy5 SLD
12345
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)
VacancyVacancy
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON DUNIT POWER CABLE(OUT)
TB 1ATB 1BTB 1CTB 2ATB 2BTB 2CTB 3ATB 3BTB 3CTB 4ATB 4B
TB 15BTB 15CTB 16ATB 16BTB 16CTB 17ATB 17BTB 17CTB 18ATB 18BTB 18CTB 19ATB 19BTB 19CTB 20ATB 20BTB 20CTB 21ATB 21BTB 21C
TB 32ATB 32BTB 32CTB 33ATB 33BTB 33CTB 34ATB 34BTB 34C
Push-in connectorfor communication
Push-in connector for power supply and FG
Output area external power supply
Output area external power supply
Terminal block
Insulation
Constant v.circuit
VacancyTB 4C
YDTB 15A
Constant v.circuit
FG+24V(UNIT)24G(UNIT)
VacancyVacancy
NCCOM-
COM+COM+
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YFNC
NCNC
NC
COM2-
NC
COM1-
COM2+ COM2+COM1+ COM1+
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF Y10Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1BY1CY1DY1E X1F
See page 59 for the pin-out of the push-in communication connector, the powersupply and FG connector.
See page 59 for the pin-out of the push-in communication connector, the powersupply and FG connector.
61 62
Remote I/O modulesProduct information
Spring clamp terminal block typeSpring clamp
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts32 -wire324VDC
-wire20.5A
-wire20.5A
Transistoroutput
pts16
Transistoroutput
pts32
I/O composite module
AJ65VBTS32-32DTUnit: mm
Spring clamp
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for
common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio : within 5%)
0.5A/point, 4A/common
1.0A 10ms or less
0.1mA or lower
0.3V or lower (TYP) 0.5A,
0.6V or lower (MAX) 0.5A
Sink type
None
1 ms or less
1 ms or less (resistive load)
10.2 to 26.4VDC (ripple ratio : within 5%)
30mA or lower (at 24VDC, with all points
ON) Not including external load current
Zener diode
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
I/O composite module
AJ65VBTS32-16DT
Unit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Description
8 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 4A/common
1.0A 10ms or less
0.1mA or lower
0.3V or lower (TYP) 0.5A,
0.6V or lower (MAX) 0.5A
Sink type
None
1ms or less
1ms or less (resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
15 mA or lower (at 24VDC, with and all point
ON) Not including external load current
Zener diode
Spring clamp
VacancyCOM+COM-
X0COM+COM-
X1COM+COM-
X5COM+COM-
X6COM+COM-
X7COM+COM-
Y8COM+
VacancyY9
COM+Vacancy
YDCOM+
VacancyYE
COM+Vacancy
YFCOM+
Vacancy
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG4 Vacancy5 SLD
12345
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON B
12345
CON CUNIT POWER CABLE(IN)
DC DC
12345
12345
CON D
FG+24V (UNIT)24G (UNIT)
VacancyVacancy
UNIT POWER CABLE(OUT)
TB 1ATB 1BTB 1CTB 2ATB 2BTB 2CTB 3ATB 3BTB 3C
TB 7ATB 7BTB 7CTB 8ATB 8BTB 8CTB 9ATB 9BTB 9CTB 10ATB 10BTB 10CTB 11ATB 11BTB 11C
TB 15ATB 15BTB 15CTB 16ATB 16BTB 16CTB 17ATB 17BTB 17C
Push-in connectorfor communication
Push-in connector for power supply and FG
Input area external power supply
2 wire type sensor(Sink output)
Terminal blockConstant voltage circuit
Insulation12345
FG+24V (UNIT)24G (UNIT)
VacancyVacancy
NCCOM- COM-
COM+COM+
X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YFNC
4.5
137
5012
151±0.5
26±0
.3
51.5
23
2-M4 mounting hole
16.531
31.5
5
4
15.5
64±0
.3
106±0.55.0 13
.513
.5
13.5 13.5
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON CBA
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPW
D
ON
COM-COM-
COM+COM+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XFNC
AJ65VBTS3-16D
42
DIN rail center
See page 59 for the pin-out of the push-in communication connector, the powersupply and FG connector.
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Description
8 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5 ms or less (at 24VDC)
1.5 ms or less (at 24VDC)
Positive common (Sink type)
16 points/common
Spring clamp terminal block 3-wire type: input
Spring clamp terminal block 2-wire type: output
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.24
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/75%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common
Spring clamp terminal block 3-wire type: input
Spring clamp terminal block 2-wire type: output
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.41
VacancyCOM1+COM1-
X0COM1+COM1-
X1COM1+COM1-
XECOM1+COM1-
XFCOM1+COM1-VacancyCOM2+COM2-
Y10COM2+Vacancy
Y11COM2+Vacancy
Y1ECOM2+Vacancy
Y1FCOM2+Vacancy
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG4 Vacancy5 SLD
12345
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON B
12345
CON CUNIT POWER CABLE(IN)
DC DC
12345
12345
CON D
FG+24V(UNIT)24G(UNIT)
VacancyVacancy
UNIT POWER CABLE(OUT)
TB 1ATB 1BTB 1CTB 2ATB 2BTB 2CTB 3ATB 3BTB 3C
TB 16ATB 16BTB 16CTB 17ATB 17BTB 17CTB 18ATB 18BTB 18CTB 19ATB 19BTB 19CTB 20ATB 20BTB 20C
TB 33ATB 33BTB 33CTB 34ATB 34BTB 34C
Push-in connectorfor communication
Push-in connector for power supply and FG
Input area external power supply
Input area external power supply
2 wire type sensor(Sink output)
Terminal block
Constant voltage circuit
Insulation12345
FG+24V(UNIT)24G(UNIT)
VacancyVacancy
Refer to the derating curve on the left for the max. input derating points of the orientations other than Front mounting (Basic orientation).
[%]100
75
50
0 10 20 30 40 50 55 [˚C]
Ambient temperature [°C]
Derating curve
NCCOM1-
NC
COM2-
NC
COM1-
COM2+ COM2+COM1+ COM1+
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF Y10Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1BY1CY1DY1E Y1F
COM2-COM1-
NC
COM2-
NC
COM1-
COM2+
CON
COM2+
CBA D
COM1+ COM1+
AJ65VBTS3-32DT
236
222
23
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPWON
13.513.5
26 5012
42
51.5 4
DIN rail center
16.531
31.5
2-M4 mounting hole
5
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F
See page 59 for the pin-out of the push-in communication connector, the powersupply and FG connector.
[%]
Max
. sim
ulta
neou
sin
put p
oint
s63 64
Remote I/O modulesProduct information
Spring clamp terminal block typeSpring clamp
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts8 -wire324VDC
-wire20.5A DC input
pts16 -wire324VDC
-wire20.5A
Transistoroutput
pts8Transistor
output
pts16
Sensor connector type (e-CON)
Overview
Part names and functions
Features
Sensor connector type (e-CON)
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65VBTCE3-8D
Sensor
Sensor
Protective cover
Protective cover for 8-point module
A6CVR-VCE8Applicable models: AJ65VBTCE3-8D
AJ65VBTCE2-8T
Protective cover for 16-point module
A6CVR-VCE16Applicable models: AJ65VBTCE3-16D
AJ65VBTCE2-16T
When attached to module
When attached to module
See page 134 for the external dimensions.
The module can be mounted in 6 different orientations.
Front mounting (Basic orientation)
Horizontal mounting Vertical mounting
Front mounting (Reverse orientation) Front mounting (Vertical orientation)
Ceiling mounting Flat surface mounting
Convenient!
OFF ON
ON OFF
Voltage
Current
Industry-standard e-CON connectors have been
adopted.
Sensor connectors allow easy wiring.
DIN rail mounting or screw mounting is selectable.
The modules are mountable in 6 different orientations.
3-wire type sensor input is available.
The 16-point modules can be attached to the DIN rail
either vertically or horizontally.
Mounting orientation in which max, simultaneous input is not limited.
Mounting orientation in which max. simultaneous is limited.Applicable modelsAJ65VBTCE3-16D (Refer to the derating curve)
Protective cover for sensor connector type (e-CON) module.Prevents incorrect switch operation and disconnection of wiring connectors.Allows visual check of the LED states through the transparent cover.Can be attached or removed easily without any tool needed.
Description
8 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5 ms or less (at 24VDC)
1.5 ms or less (at 24VDC)
8 points/common
(Sensor connector (e-CON) 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
30mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.1
Unit: mm
LINKCABLE(IN)
LINKCABLE(OUT)
UNIT POWER CABLE(IN)
Push-in connectorfor communication
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
3 wire type sensor(Sink output)
With operation switching input
3 wire type sensor(Sink output)
2 wire type sensor(Sink output)
Push-in connector for power supply and FG
Operationswitching input
Insulation
8 F9 A B C D E
B RA
TE
24
14
220
1
0 71 2 3 4 5 6
STA
TIO
N N
O.
810
ONPW L RUN L ERR.40
CBA DCON X 8 FEDCBA9
X 0 7654321
AJ65VBTCE3-16D
LED indication
PWL RUN
L ERR
X0 to 1F
LED name DetailsON: Power ON OFF: Power OFFON: When communication is normal.OFF: When communication is interrupted (time-over error)ON: Communication errorFlashing at regular intervals: The station No. and/or
transmission rate switch setting has been changed while the power is on.
Flashing irregularly: The terminating resistor setting is incorrect, or the module and CC-Link dedicated cables are being affected by noise.
ON: Input is ON, OFF: Input is OFF
DIN rail hookUsed to mount the module to the DIN rail.
Mounting bracketThis removable fitting is used to mount the module to a panel.
I/O connectorConnector for I/O signal connection.
1 DA2 DB3 DG45 SLD
12345
CON A
1 DA2 DB3 DG45 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
DC DC
12345
12345
CON DFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
1234
CON1
1234
CON2
1234
CON8
1234
CON3Detection circuit
Vacancy
Vacancy
Detec
tion cir
cuit
Detec
tion cir
cuit
Detectioncircuit
X7
X6
X5
X4
X3
X2
X1
X0
76543210
L ERR.
L RUN
PWAJ65VBTCE3-8D
3116.5
43.540.5
2630.5
40
100
4
41.5
5
CON
A
B
C
D
ON12345678910
4020108421421
STATI
ON
N O.BRATE
DIN rail center
2-M4 mounting hole
40.5
54±0.3
13.5 13.5
83±0
.5
114±
0.5
13.5
13.510
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
Transmission rate setting switch
Station No. setting switch
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Setting value 4
OFFOFFOFFOFFON
Transmissionrate2
OFFOFFONONOFF
Setting switch
1OFFONOFFONOFF
Push-in communication connectorPush-in connector for communication line connection.
Pin No.12345
Signal NameDADBDGNCSLD
Power supply / FG connectorPush-in connector for module's power supply line and FG connections.
Pin No.12345
Signal NameFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
CONA
CONB
12345
CONC
COND
12345 8
7
6
5
4
3
2
1
CON4 3 2 1
1
2
3
4
+24V
+V
24G
X0 to X7
Pin No. Signal Name
CON1to
CON8
See page 65 for the pin-out of the push-in communication connector, the powersupply and FG connector.
AJ65V
BT
CE
3-16D
CD
AJ65VBTCE3-16D
AJ65VBTCE3-16D
AJ65VBTCE3-16D
AJ65VBTCE3-16D
Con
nect
or p
in N
o.
Con
nect
or p
in N
o.
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
65 66
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire324VDC Vertical
Output module
AJ65VBTCE2-16T
Unit: mm
Output module
AJ65VBTCE2-8TUnit: mm
Sensor
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Protective
function
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Sensor
Input module
AJ65VBTCE3-16DUnit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Sensor
Refer to the derating curve on the left for input derating of the orientations other than Front mounting (Basic orientation).
[%]100
75
50
0 10 20 30 40 50 55 [˚C]
Ambient temperature [°C]
Derating curve
[%]
Max
. sim
ulta
neou
sin
put p
oint
s
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
Input module
AJ65VBTCE3-32DUnit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Sensor
Refer to the derating curve on the left for input derating of the orientations other than Front mounting (Basic orientation).
[%]100
75
50
0 10 20 30 40 50 55 [˚C]
Ambient temperature [°C]
Derating curve
[%]
Max
. sim
ulta
neou
sin
put p
oint
s
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/62.5%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common
(Sensor connector (e-CON) 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.1
Description
32 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/75%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
32 points/common
(Sensor connector (e-CON) 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio : within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.16
Description
8 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 0.8A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
1 ms or less
1 ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
5mA (at 24VDC, with all points ON)
Not including external load current
Zener diode
8 points/common
(sensor connector (e-CON) 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.1
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
1ms or less
1ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
10 mA (at 24VDC, with all points ON)
Not including external load current
Zener diode
16 points/common
(Sensor connector (e-CON) 2-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.1
4.5
100
4
50
8.5
114±0.5
33±0
.3
8 F9 A B C D E
B R
ATE
24
14
220
1
0 71 2 3 4 5 6
STA
TIO
N N
O.
810
ONPW L RUN L ERR.40
CBA DCON X 8 FEDCBA9
X 0 7654321
AJ65VBTCE3-16D
41.5
23.5
2-M4 mounting hole
16.531
31.5
5
4
8.5
64±0
.3
41.5
83±0.55.0
13.5
13.5
13.5
DIN rail center
13.5
45.5
DIN rail center
X7
X6
X5
X4
X3
X2
X1
X0
76543210
L ERR.
L RUN
PWAJ65VBTCE3-8D
3116.5
43.540.5
2630.5
40
100
4
41.5
5
CON
A
B
C
D
ON12345678910
4020108421421
STATI
ON
N O.BRATE
DIN rail center
2-M4 mounting hole
40.5
54±0.3
13.5 13.5
83±0
.5
114±
0.5
13.5
13.510
1 DALINKCABLE(IN)
2 DB3 DG45 SLD
12345
CON A
1 DALINKCABLE(OUT)
2 DB3 DG45 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON DFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON2
1234
CON8
Vacancy
Vacancy
Push-in connectorfor communication
Push-in connector for power supply and FG
LINKCABLE(IN)
LINKCABLE(OUT)
Push-in connectorfor communication
Push-in connector for power supply and FG
Insulation
1 DA2 DB3 DG45 SLD
12345
CON A
1 DA2 DB3 DG45 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON DFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON2
1234
CON16
Vacancy
Vacancy
Insulation
Constant voltage circuit
Constant voltage circuit
8
7
6
5
4
3
2
1
CON4 3 2 1
4.5
100
4
50
8.5
114±0.5
33±0
.3
8 F9 A B C D E
B R
ATE
24
14
220
1
0 71 2 3 4 5 6
STA
TIO
N N
O.
810
ONPW L RUN L ERR.40
CBA DCON X 8 FEDCBA9
X 0 7654321
AJ65VBTCE3-16D
41.5
23.5
2-M4 mounting hole
16.531
31.5
5
4
8.5
64±0
.3
41.5
83±0.55.0
13.5
13.5
13.5
DIN rail center
13.5
45.5
DIN rail center
CON
1234
1234
7 8654321
CON 15 1614131211109
1
2
3
4
+24V
NC
NC
Y0 to Y7
Pin No. Signal Name
CON1to
CON8
1
2
3
4
+24V
+V
24G
X0 to XF
Pin No. Signal Name
CON1to
CON16
CON
1234
1234
7 8654321
CON 15 1614131211109
1
2
3
4
+24V
NC
NC
Y0 to YF
Pin No. Signal Name
CON1to
CON16
See page 65 for the pin-out of the push-in communication connector, the powersupply and FG connector.
See page 65 for the pin-out of the push-in communication connector, the powersupply and FG connector.
See page 65 for the pin-out of the push-in communication connector, and the powersupply & FG connector.
1
2
3
4
+24V
+V
24G
X0 to X1F
Pin No. Signal Name
CON1to
CON32
See page 65 for the pin-out of the push-in communication connector, and the powersupply & FG connector.
Insulation
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG45 SLD
12345
CON A
1 DA2 DB3 DG45 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(IN)
Push-in connectorfor communication
DC DC
12345
12345
CON DUNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON2
1234
CON16
1234
CON3
3 wire type sensor(Sink output)
With operation switching input
3 wire type sensor(Sink output)
2 wire type sensor(Sink output)
Push-in connector for power supply and FG
Operationswitching input
Detection circuit
Vacancy
Vacancy
Detectioncircuit
FG+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
Detec
tion cir
cuit
Detec
tion cir
cuit
1 DALINKCABLE(IN)
LINKCABLE(OUT)
2 DB3 DG45 SLD
12345
CON A
1 DA2 DB3 DG45 SLD
12345
CON B
12345
12345
CON CFG
+24V (UNIT)24G (UNIT)+24V (I/O)24G (I/O)
UNIT POWER CABLE(IN)
DC/DC
12345
12345
CON DFG
+24V (UNIT)24G (UNIT)+24V (I/O)24G (I/O)
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON2
1234
CON32
1234
CON3
One-touch connector for communication
One-touch connector forpower supply and FG
3 wire typesensor(sink output)
2 wire type sensor(sink output)
With operationswitch input3 wire typesensor(sink output)
Detectioncircuit
Insulation
Vacancy
Operationswich input
Vacancy
Detectioncircuit
Detec
tion cir
cuit
Detec
tion cir
cuit
26±0
.3
1D 1E 1F
FE
18 19 1A 1B 1C
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPWON
DA B C 11 12 13 14 15 16 1710X
31.5
3116
.5
15513.5
508.
54.
5
23.5
41.5
4
AJ65VBTCE3-32D
D9 A B C81 2 3 4 5 6 70X
13.5129±0.5
169±0.5
2-M4 mounting hole
5
DIN rail center
13.545.5
5.0
13.5
64±0
.3
4
72.5
DIN rail center
CON
CON
1234
1234
32313026 27 28 292518 19 20 21 22 23 2417
1514139 10 11 1281 2 3 4 5 6 7 16
67 68
Remote I/O modulesProduct information
Sensor connector typeSensor
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts16 -wire324VDC Vertical
DC input
pts32 -wire324VDC Vertical
Protection
-wire20.1A Vertical
Protection
-wire20.1A Vertical Transistor
output
pts16
Transistoroutput
pts8
SensorI/O composite module
AJ65VBTCE32-16DTUnit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for
common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Description
8 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7kΩ
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common
(Sensor connector (e-CON) 3-wire type: input)
(Sensor connector (e-CON) 2-wire type: output)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (at 24VDC, with all points ON)
DC type noise voltage 500Vp-p, noise
width 1µs, noise carrier frequency 25 to
60Hz (noise simulator condition)
500VAC across all DC external terminals
and ground for 1min
10MΩ or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.11
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Description
8 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 0.8A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A,
0.2V or lower (MAX) 0.1A
Positive common (Sink type)
Overload protection, overvoltage
protection, overheat protection
1ms or less
1ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
5mA or lower (at 24VDC, with all points ON)
Not including external load current
Zener diode
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
SensorI/O composite module
AJ65VBTCE32-32DTUnit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for
common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7kΩ
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
32 points/common
(Sensor connector (e-CON) 3-wire type: input)
(Sensor connector (e-CON) 2-wire type: output)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
DC type noise voltage 500Vp-p, noise
width 1µs, noise carrier frequency 25 to
60Hz (noise simulator condition)
500VAC across all DC external terminals
and ground for 1min
10MΩ or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.16
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Description
16 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A,
0.2V or lower (MAX) 0.1A
Positive common (Sink type)
Overload protection, overvoltage
protection, overheat protection
1ms or less
1ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
10mA or lower (at 24VDC, with all points ON)
Not including external load current
Zener diode
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications4.5
100
4
50
8.5
114±0.5
33±0
.3
8 F9 A B C D E
B R
ATE
24
14
220
1
0 71 2 3 4 5 6
STA
TIO
N N
O.
810
ONPW L RUNL ERR.40
CBA DCON X 8 FEDCBA9
X 0 7654321
AJ65VBTCE3-16D
41.5
23.5
2-M4 mounting hole
16.531
31.5
5
4
8.5
64±0
.3
41.5
83±0.5 5.0
13.5
13.5
13.5
DIN rail center
13.5
45.5
DIN rail center
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON DFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON8
1234
CON16
Constant voltage circuit
1234
CON9
Insulation
Operationswitching input
Push-in connector for power supply and FG
With operation switching input3 wire type sensor (Sink output)
Push-in connectorfor communication
LINKCABLE(IN)
LINKCABLE(OUT)
CON
1234
1234
7 8654321
CON 15 1614131211109
1
2
3
4
1
2
3
4
+24V
+V
24G
X0 to X7
+24V
NC
NC
Y8 to YF
Pin No. Signal Name
CON1to
CON8
CON9to
CON16
See page 65 for the pin-out of the push-in communication connector, the powersupply and FG connector.
Detec
tion cir
cuit
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON A
1 DA2 DB3 DG4 Vacancy5 SLD
12345
CON B
12345
12345
CON CFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(IN)
DC DC
12345
12345
CON DFG
+24V(UNIT)24G(UNIT)+24V(I/O)24G(I/O)
UNIT POWER CABLE(OUT)
I/O POWER CABLE(IN)
I/O POWER CABLE(OUT)
1234
CON1
1234
CON8
1234
CON16
Constant voltage circuit
1234
CON9
Insulation
Operationswitching input
Push-in connector for power supply and FG
With operation switching input3 wire type sensor (Sink output)
Push-in connectorfor communication
LINKCABLE(IN)
LINKCABLE(OUT)
Detec
tion cir
cuit
1
2
3
4
+24V
+V
24G
X0 to XF
Pin No. Signal Name
1
2
3
4
+24V
NC
NC
Y10 to Y1F
Pin No. Signal Name
CON1to
CON16
CON17to
CON32
See page 65 for the pin-out of the push-in communication connector, and the powersupply & FG connector.
26±0
.3
1D 1E 1F
FE
18 19 1A 1B 1C
401
202
104
81
42
B R
ATE
STA
TIO
N N
O.
CON
E
6
D
5
C
4
B
3
A
2
9
1
F
7
8
0
L ERR.L RUNPWON
DA B C 11 12 13 14 15 16 1710Y
31.5
3116
.5
15513.5
508.
54.
5
23.5
41.5
4
AJ65VBTCE32-32DT
D9 A B C81 2 3 4 5 6 70X
13.5129±0.5
169±0.5
2-M4 mounting hole
5
DIN rail center
13.545.5
5.0
13.5
64±0
.3
4
72.5
DIN rail center
CON
CON
1234
1234
32313026 27 28 292518 19 20 21 22 23 2417
1514139 10 11 1281 2 3 4 5 6 7 16
69 70
Remote I/O modulesProduct information
Sensor connector type (e-CON)Sensor
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire324VDC Protection
-wire20.1A VerticalTransistor
output
pts8DC input
pts16 -wire324VDC Protection
-wire20.1A VerticalTransistor
output
pts16
Push-in connector type
Overview
Part names and functions
Features
Push-in connector typePush-in
Push-in connectors allow easy wiring.
3-wire type sensor input is available.
The modules are mountable in 6 different orientations.
* The actual modules may slightly differ in shapes from the photos shown.
402010842
142
1
STATION NO
A
X0
X1
X2
X3
X4
X5
X6
X7
PW
L RUN
L ERR
01234567
J65VBTCU3-8D1
CONA
CONB
LINK
CONC
COND
402010842
142
1
STATION NO
PW
L RUN
L ERR
67
8 9 A B C D E F
45
23
01
A J65VBTCU3-16D1
CONA
CONB
LINK
CONC
COND
B RATE
B RATE
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
3. Station No. setting switch
3
4
6
5
4
6
5
2
1
1
3
2
4. Push-in communication connectorPush-in connector for communication line connection.
6. Connector for I/O signal connection
7. DIN rail hookUsed to mount the module to the DIN rail.
5. Push-in connector for power supply & FGPush-in connector for module's power supply line and FG connections.
2. Transmission rate setting switch
1. Operation status LEDs
PW
L RUN
L ERR
X0 to 1FY0 to 1F
LED name DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.Turns ON when a transmission error (CRC error) occurs and OFF when the timeout is reached (L RUN also goes out.)Turns ON due to incorrect station No. or transmission rate setting.Flashing when the station No. and/or transmission rate switch setting has been changed while the power is on.Indicates the input ON/OFF status. Indicator is ON when the input is ON, and is OFF when the input is OFF.
Connector pin No.
Pin No.Signal Name
5SLD
4NC
3DG
2DB
1DA
5 4 3 2 1
Pin No.SignalName
524G(I/O)
4+24V(I/O)
324G
(UNIT)
2+24V
(UNIT)
1
FG
Connector pin No.
5 4 3 2 1
4. Terminal block
5. Connector for I/O signal connection
6. DIN rail hookUsed to mount the module to the DIN rail.
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
3. Station No. setting switch
2. Transmission rate setting switch
1. Operation status LEDs
PWL RUN
L ERR
X0 to 1FY0 to 1F
LED name DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.Turns ON when a transmission error (CRC error) occurs and OFF when the timeout is reached (L RUN also goes out.)Turns ON due to incorrect station No. or transmission rate setting.Flashing when the station No. and/or transmission rate switch setting has been changed while the power is on.Indicates the input ON/OFF status. Indicator is ON when the input is ON, and is OFF when the input is OFF.
1
564
3 2
7
DB
DA
SLD
DG +24V 24G
(FG)
COM
COM
PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTC1-32D1
ONX1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F
X0-XF
X10-X1FX0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XA
XB
XC
XD
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Settingvalue 4
OFFOFFOFFOFFON
Transmissionrate2
OFFOFFONONOFF
Setting switch
1OFFONOFFONOFF
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Settingvalue 4
OFFOFFOFFOFFON
Transmissionrate2
OFFOFFONONOFF
Setting switch
1OFFONOFFONOFF
CON A
CON B
CON C
CON D
24G+24V
FG
DG
SLD
DA
DB
7
AJ65VBTCU -8 AJ65VBTCU -16
AJ65SBTC -16AJ65SBTC -32
71 72
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Unit: mm
Input module
AJ65VBTCU3-16D1Unit: mm
Input module
AJ65VBTCU3-8D1
Unit: mm
Input module
AJ65SBTC4-16DN
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Push-in Push-in
Push-in
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Detailed specificationsInput specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
OFF ON
ON OFF
Voltage
Current
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
External dimensions & terminal layoutExternal device connection diagram
Unit: mm
Input module
AJ65SBTC4-16DE
Push-in
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
OFF ON
ON OFF
Voltage
Current
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Description
8 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
15VAC/3mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
8 points/common (Push-in connector 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
15VAC/3mA or higher
3VAC/0.5mA or lower
Approx. 4.7k
0.2 ms or less (at 24VDC)
0.2 ms or less (at 24VDC)
16 points/common (Push-in connector 3-wire type)
Positive common (Sink type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.19
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common (Push-in connector 4-wire type)
Positive common (Sink type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common (Push-in connector 4-wire type)
Negative common (Source type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
12345
12345
DADBDGNCSLD
LINK CABLE(IN)
Push-in connectorfor communication
CON.A
12345
12345
DADBDGNCSLD
UNIT POWER CABLE (IN)
I/O POWER CABLE (IN)
UNIT POWERCABLE (OUT)I/O POWERCABLE (OUT)
CON.B
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
Push-in connector for power supply and FG
CON.C
1234
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
CON.D
CON1
DC DC
Insulation
R
R
3 wire type sensor (Sink output)
Det
ectio
nci
rcui
t
1234
CON2
R
R
2 wire type sensor (Sink output)
1234
CON8
R
R
(Sink output)
LINK CABLE(OUT)
3116.5
62
115
41
A
X0
X1
X2
X3
X4
X5
X6
X7
PW
L RUN
L ERR
01234567
J65VBTCU3-8D1
CONA
CONB
LINK
CONC
COND
PW/AUX
623116.5
115
60
X0~X7 X8~XF
PW
L RUN
L ERR
67
8 9 A B C D E F
45
23
01
A J65VBTCU3-16D1
CONA
CONB
LINK
CONC
COND
PW/AUX
12345
12345
DADBDGNCSLD
LINK CABLE(IN)
Push-in connectorfor communication
CON.A
12345
12345
DADBDGNCSLD
LINK CABLE(OUT)
UNIT POWER CABLE (IN)
I/O POWER CABLE (IN)
UNIT POWERCABLE (OUT)I/O POWERCABLE (OUT)
CON.B
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
Push-in connector forpower supply and FG
CON.C
1234
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
CON.D
CON1
DC/DC
Insulation
R
R
3 wire type sensor (Sink output)
1234
CON2
R
R
2 wire type sensor (Sink output)
Detectioncircuit
1234
CON16
R
R
(Sink output)
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
2341
CON2
CON1
CON3
CON4
CON5
CON6
CON7
CON8
234
1
CON2
CON1
CON3
CON4
CON5
CON6
CON7
CON8
234 1
CON10
CON9
CON11
CON12
CON13
CON14
CON15
CON16
234
1
2
3
4
X0 to X7
+V
+24V
24G
Pin No. Signal name
CON1
to
CON8
1
2
3
4
X0 to XF
+V
+24V
24G
Pin No. Signal name
CON1
to
CON16
1
2
3
4
1
2
3
4
X0
X8
+24V
24G
X1
X9
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X2
XA
+24V
24G
X3
XB
+24V
24G
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
X4
XC
+24V
24G
X5
XD
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X6
XE
+24V
24G
X7
XF
+24V
24G
Pin No. Signal name
CON5
CON6
CON7
CON8
Det
ectio
nci
rcui
tDe
tectio
ncir
cuit
4wire type sensor(sink output)
Black
Orange
Brown
Blue
Black
Orange
Brown
Blue
Black
Orange
Brown
Blue
21 DA
DB3 DG4 SLD
DC/DC5 +24V6 FG7 24G
8 CTL+9 COM-
Insulation
CON81
2
3
4
R
RCON11
2
3
4
R
R
R
R
RR
R
R
CON21
2
3
4 R
R
3wire type sensor(sink output)
2wire type sensor(sink output)
External power supplyfor input
I/O module power supply
Det
ectio
nci
rcui
tD
etec
tion
circ
uit
Det
ectio
nci
rcui
t
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
234
1
2
3
4
1
2
3
4
X0
X8
+24V
24G
X1
X9
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X2
XA
+24V
24G
X3
XB
+24V
24G
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
X4
XC
+24V
24G
X5
XD
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X6
XE
+24V
24G
X7
XF
+24V
24G
Pin No. Signal name
CON5
CON6
CON7
CON8
4-wire type sensor(source output)
Black
Orange
Brown
Blue
Black
Orange
Brown
Blue
Black
Orange
Brown
Blue
21 DA
DB3 DG4 SLD
DC/DC5 +24V6 FG7 24G
8 CTL+9 COM-
Insulation
CON81
2
3
4
R
RCON11
2
3
4
R
R
R
R
RR
R
R
CON21
2
3
4 R
R
3-wire type sensor(source output)
2-wire type sensor(source output)
External power supplyfor input
I/O module power supply
Det
ectio
nci
rcui
tD
etec
tion
circ
uit
Det
ectio
nci
rcui
t
24G(FG)DB
DA +24V
SLD
DG
COM-
COM+
ON1241248102040B RATESTATION NO.FEDCBA9X8
AJ65SBTC4-16DN
7654321X0
24G+24V
YFYEYDYCYBYAY9Y8X7X6X5X4X3X2X1X0
450
16.5
40
118
109 +1 0 (Mounting pitch)
Mounting hole (M4 mounting screw)DIN rail center
7.5
7.9
About 105˚
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
24G(FG)DB
DA +24V
SLD
DG
COM-
COM+
ON1241248102040B RATESTATION NO.FEDCBA9X8
AJ65SBTC4-16DE
7654321X0
24G+24V
YFYEYDYCYBYAY9Y8X7X6X5X4X3X2X1X0
450
16.5
40
118
109 +1 0 (Mounting pitch)
Mounting hole (M4 mounting screw)DIN rail center
7.5
7.9
About 105˚
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
24G+24V
73 74
Remote I/O modulesProduct information
Push-in connector typePush-in
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts8 -wire324VDC Vertical
DC input
pts16 -wire324VDC Vertical
DC input
pts16 -wire424VDC
DC input
pts16 -wire424VDC
Output module
AJ65SBTC1-32T1
Unit: mm
Output module
AJ65SBTC1-32T
Output module
AJ65VBTCU2-16TUnit: mm
Push-in
Push-in
Push-in
623116.5
115
60
X0~X7 X8~XF
PW
L RUN
L ERR
67
8 9 A B C D E F
45
23
01
A J65VBTCU3-16D1
CONA
CONB
LINK
CONC
COND
PW/AUX
Output specificationsNumber of output pointsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush current Leakage current at OFF Max. voltage drop at ONOutput formProtective function
ResponsetimeOutput area external power supplySurge suppression Wiring method for commonNo. of stations occupiedI/O module power supplyNoise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
0.1mA or lower
None
Output specificationsDescription
AJ65SBTC1-32T AJ65SBTC1-32T1
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ONON OFFVoltageCurrent
VoltageCurrent
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Input module
AJ65SBTC1-32D1
Unit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Input module
AJ65SBTC1-32D
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
15VAC/3mA or higher
3VAC/0.5mA or lower
0.2 ms or less (at 24VDC)
0.2 ms or less (at 24VDC)
Push-in
Push-in
Output module
AJ65VBTCU2-8TUnit: mm
Push-in
AJ65SBTC1-32D AJ65SBTC1-32D1Input specifications
Description
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Refer to the derating curve on the left for the input derating of the orientations other than Front mounting (Basic orientation).
[%]
[%]
100
80
50
0 10 20 30 40 50 55 [˚C]
Ambient temperature [°C]
Derating curve
Max
. sim
ulta
neou
sin
put p
oint
s
DC input
pts32 -wire124VDC
DC input
pts32 -wire124VDC
Protection
-wire20.1A VerticalTransistor
output
pts8
High speedinput
32 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/80%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5 ms or less (at 24VDC)
1.5 ms or less (at 24VDC)
32 points/common (Push-in connector 1-wire type)
Positive/negative shared common (sink/source type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.16
Description
8 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 0.8A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Sink type
Protection against overload, overvoltage
and overheat
1ms or less
1ms or less (Rated load, resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
5mA or lower (TYP.24VDC/common)
Zener diode
8 points/common (Push-in connector 2-wire type)
Assignment of 32 points/station (8 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
35mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 3.2A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.1A, 0.6V or lower (MAX) 0.1A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
16 points/common (Push-in connector 1-wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4 VDC (ripple rate: within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.19
Description16 pointsPhotocoupler12/24VDC10.2 to 26.4VDC (ripple ratio: within 5%)0.1A/point, 1.6A/common0.7A 10ms or less0.1mA or lower0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1ASink typeProtection against overload, overvoltage and overheat1ms or less 1ms or less (Resistive load)10.2 to 26.4VDC (ripple ratio: within 5%)10mA or lower (TYP.24VDC/common) Zener diode16 points/common (Push-in connector 2-wire type)Assignment of 32 points/station (16 points used)20.4 to 26.4VDC (ripple rate: within 5%)40mA or lower (at 24VDC, with all points ON)Tested by a DC type noise simulator of 500Vp-p, noise width 1µs and 25 to 60Hz frequency500 VAC across all DC external terminals and ground for 1 min10M or higher, between DC external terminals and ground by a 500VDC insulation resistance tester0.19
12345
12345
DADBDGNCSLD
Push-in connector for communication
CON.A
12345
12345
DADBDGNCSLD
LINK CABLE(OUT)
LINK CABLE(IN)
UNIT POWER CABLE(IN)
I/O POWER CABLE(IN)
UNIT POWERCABLE (OUT)I/O POWERCABLE (OUT)
CON.B
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
Push-in connector forpower supply and FG
CON.C
1234
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
CON.D
CON1
DC DC
Insulation
1234
CON2
1234
CON16
L
L
L
Constant voltage circuit
DADBDGSLD
DC DC+24VFG24G
CTL+COM-
L
L
L
L
CTL+COM-
L
CON11
2
3
4
CON81
2
3
4
89
89
21
34567
Module power supply
Insulation
I/O power supply(External power supply)
Constant voltagecircuit
Load power supply
When I/O power & load power is supplied
DB
DA
SLD
DG +24V 24G
(FG)
COM
COM
PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTC1-32T
ON
2-4.5 x 5.1 mounting hole (M4 mounting screw)
118
16.5
50
X1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F
X0-XF
X10-X1FX0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XB
XC
XD
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
4
109 (Mounting pitch)+1
0
7.5
11
20
7.9
(About 110°)
DIN rail
1
CON2
CON1
CON3
CON4
CON5
CON6
CON7
CON8
234 1
CON10
CON9
CON11
CON12
CON13
CON14
CON15
CON16
234
1
2
3
4
Y0 to YF
NC
+24V
NC
Pin No. Signal name
CON1
to
CON16
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
234
1
2
3
4
1
2
3
4
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Pin No. Signal name
1
2
3
4
1
2
3
4
Y8
Y9
YA
YB
YC
YD
YE
YF
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Pin No. Signal name
1
2
3
4
1
2
3
4
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
Pin No. Signal name
CON5
CON6
CON7
CON8
3116.5
62
115
41
A
X0
X1
X2
X3
X4
X5
X6
X7
PW
L RUN
L ERR
01234567
J65VBTCU3-8D1
CONA
CONB
LINK
CONC
COND
PW/AUX
DB
DA
SLD
DG +24V 24G
(FG)
COM
COM
PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTC1-32D1
ON
2-4.5 x 5.1 mounting hole (M4 mounting screw)
118
16.5
50
X1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F
X0-XF
X10-X1FX0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XB
XC
XD
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
4
109 (Mounting pitch)+1
0
12345
12345
DADBDGNCSLD
Push-in connectorfor communication
CON.A
12345
12345
DADBDGNCSLD
LINK CABLE(OUT)
LINK CABLE(IN)
UNIT POWER CABLE (IN)
I/O POWER CABLE (IN)
UNIT POWERCABLE (OUT)I/O POWERCABLE (OUT)
CON.B
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
Push-in connector for power supply and FG
CON.C
1234
12345
12345
FG+24V(UNIT) 24G(UNIT)+24V(I/O) 24G(I/O)
CON.D
CON1
DC DC
Insulation
1234
CON2
1234
CON8
L
L
L
Constant voltage circuit
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
234
7.5
11
20
7.9
(About 110°)
DIN rail
1
CON2
CON1
CON3
CON4
CON5
CON6
CON7
CON8
234
1
2
3
4
Y0 to Y7
NC
+24V
NC
Pin No. Signal name
CON1
to
CON8
1
2
3
4
1
2
3
4
X0
X1
X2
X3
X4
X5
X6
X7
Pin No. Signal name
1
2
3
4
1
2
3
4
X8
X9
XA
XB
XC
XD
XE
XF
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
X10
X11
X12
X13
X14
X15
X16
X17
Pin No. Signal name
1
2
3
4
1
2
3
4
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
Pin No. Signal name
CON5
CON6
CON7
CON8
21 DA
DB3 DG4 SLD
DC/DC5 +24V6 FG7 24G
8 COM9 COM
R
Insulation
Module power supply
I/O power supply
R
R
CON1
R
1
2
3
4
R
R
R
CON2
R
1
2
3
4
R
R
R
CON8
R
1
2
3
4
40
40
75 76
Remote I/O modulesProduct information
Push-in connector typePush-in
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Protection
-wire20.1A Vertical
Protection
-wire10.1A
-wire10.1A
Transistoroutput
pts16
Transistoroutput
pts32
Transistoroutput
pts32Low
leakage
Push-in
Push-in
Push-in
Push-in
Unit: mm
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
15V/3.0mA or higher
3V /0.5mA or lower
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area external
power supply
Surge suppression
16 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.1A, 0.6V or lower (TYP) 0.1A
Sink type
Protection against overload, overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
17mA or lower (at 24VDC, with all points ON) Not including external load current
Zener diode
I/O composite module
AJ65SBTC1-32DT1
I/O composite module
AJ65SBTC1-32DT2
I/O composite module
AJ65SBTC1-32DT3
I/O composite module
AJ65SBTC1-32DT
Input specifications
Output specifications
DescriptionAJ65SBTC1-32DT AJ65SBTC1-32DT1
14V /3.5mA or higher
6V/1.7mA or lower
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
AJ65SBTC1-32DT2
15V /3.0mA or higher
3 V/0.5mA or lower
0.2ms or less (at 24VDC)
0.2ms or less (at 24VDC)
AJ65SBTC1-32DT3
DescriptionAJ65SBTC1-32DT AJ65SBTC1-32DT2
0.1mA or lower
None
AJ65SBTC1-32DT1 AJ65SBTC1-32DT3
External dimensions & terminal layout
External device connection diagramDetailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
I/O composite module
AJ65SBTC4-16DT2
Unit: mm
I/O composite module
AJ65SBTC4-16DTPush-in
Push-in
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
8 points
Photocoupler
24VDC
19.2 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or less
0.25mA or lower
0.3V or lower (TYP) 0.5A, 0.6V or lower (TYP) 0.5A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
13mA or lower (at 24VDC, with all points ON)
Not including external load current
Zener diode
Input specifications
Output specifications
Description
DescriptionAJ65SBTC4-16DT AJ65SBTC4-16DT2
0.1mA or lower
None
External device connection diagram External dimensions & terminal layout
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
<Examples of 4-wire, 3-wire, and 2-wire type connections>
<Other connection examples>
DC input
pts8 -wire424VDC Protection
-wire40.5A
DC input
pts8 -wire424VDC
-wire40.5A
Transistoroutput
pts8
Transistoroutput
pts8Low
leakage
8 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14VAC/3.5mA or higher
6VAC/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common (Push-in connector 4-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (TYP. 24VDC)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.15
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14V/3.5mA or higher
6V/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
32 points/common (Push-in connector 1-wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (TYP. 24VDC)
Tested by a DC type noise simulator of 500Vp-p, noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals and ground for 1min
10M or higher, between DC external terminals and ground by a 500VDC insulation resistance tester
0.16
DADBDGSLD
DC/DC+24VFG24G
8 COM+9
L
L
8 COM+9 COM-
L
R
R
R
CON1 to CON4
R
1
2
3
4
CON5 to CON81
2
3
4
21
34567
Module power supply
Insulation
I/O power supply(External power supply)
Constant voltagecircuit
Load power supply
When common power supplyis used for I/O and loads.
COM-
DB
DA
SLD
DG +24V 24G
(FG)
COM
COM
PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTC1-32D1
ON
2-4.5 x 5.1 mounting hole (M4 mounting screw)
118
16.5
50
X1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F
X0-XF
X10-X1FX0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XB
XC
XD
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
4
109 (Mounting pitch)+10
7.5
11
20
7.9
(About 110°)
DIN rail
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
234
1
2
3
4
1
2
3
4
X0
X1
X2
X3
X4
X5
X6
X7
Pin No. Signal name
1
2
3
4
1
2
3
4
X8
X9
XA
XB
XC
XD
XE
XF
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Pin No. Signal name
1
2
3
4
1
2
3
4
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
Pin No. Signal name
CON5
CON6
CON7
CON8
1234567
DADBDGSLD+24VFG24G
89
CTL+COM-
DC DC
Insulation
Module powersupply
4-wire type sensor (Sink output / sink input)
Black (white)Orange (orange)Brown (red)Blue (black)
COM11234
RR
3 wire type sensor (Sink output)
Det
ectio
nci
rcui
t
COM21234
RR
2 wire type sensor (Sink output)
DC24V
COM31234
RR
Constantvoltagecircuit
(Sink output)
DC24V
(Sink input)
Constantvoltagecircuit
1234567
DADBDGSLD+24VFG24G
89
CTL+COM-
DC DC
Insulation
Module powersupply
COM11234
RR
COM31234
RR
L
DB
DA
SLD
DG +24V 24G
(FG)
COM
COM
PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
MITSUBISHI AJ65SBTC4-16DT
ON
2-4.5 x 5.1 mounting hole (M4 mounting screw)
118
16.5
50
X1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F
X0
X1
X2
X3
X4
X5
X6
X7
X8
X9
XB
XC
XD
XE
XF
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
4
109 (Mounting pitch)+1
0
7.5
11
20
7.9
(About 110°)
DIN rail
1
CO
N2
CO
N1
CO
N3
CO
N4
CO
N5
CO
N6
CO
N7
CO
N8
234
1
2
3
4
1
2
3
4
X0
Y8
+24V
24G
X1
Y9
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X2
YA
+24V
24G
X3
YB
+24V
24G
Pin No. Signal name
CON1
CON2
CON3
CON4
1
2
3
4
1
2
3
4
X4
YC
+24V
24G
X5
YD
+24V
24G
Pin No. Signal name
1
2
3
4
1
2
3
4
X6
YE
+24V
24G
X7
YF
+24V
24G
Pin No. Signal name
CON5
CON6
CON7
CON8
Det
ectio
nci
rcui
tD
etec
tion
circ
uit
40
40
77 78
Remote I/O modulesProduct information
Push-in connector typePush-in
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts16 -wire124VDC Protection
-wire10.1A
DC input
pts16 -wire124VDC Protection
-wire10.1A
DC input
pts16 -wire124VDC
-wire10.1A
DC input
pts16 -wire124VDC
-wire10.1A
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Transistoroutput
pts16
Lowleakage
Lowleakage
High speedinput
High speedinput
40-pin FCN connector type
Overview
Part names and functions
Features
40-pin FCN connector type40-pin
The module can be mounted in 6 different orientations.
Front mounting (Horizontal)
Front mounting
Ceiling mounting
Flat surface mounting
The 40-pin connector (FCN connector type) allows
connection of various devices.
The modules are mountable in 6 different orientations.
* The actual modules may slightly differ in shapes from the photos shown.
Mounting orientation in which max. simultaneous input is not limited.
Mounting orientation in which max. simultaneous input is limitedApplicable modelsAJ65SBTCF1-32DT (Refer to the derating curve)
124124102040 8
ON
STATION NO. B RATEX0-XF
X10-X1F
X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM
MITSUBISHI A J65SBTCF1-32D
AJ65VBTCF1-32DT1
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Setting value Transmission rate
Operation status LEDs Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
Transmission ratesetting switch
Station No. setting switch
I/O displayselector switch
DIN rail mounting hookThis hook is used to mount the module on the DIN rail.
Connector for I/O signal connections.
Terminal block for connection of compact remote I/O module power supply, transmissions, and input/output signals.
Terminal block Connector
4020
108421421
CON.A CON.B
PW
LINK X0
XF
CON.C CON.D
PW/AUX.
L RUN
L ERR
0 1 2 3 4 5 6 7
8 9 A B C D E F
Y10
Y1F
AJ65VBTCF1-32DT1
STATION NOB RATE
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Setting value Transmission rate
Transmission ratesetting switch
Connector for I/O signal connections.
Push-in connector forcommunication
Push-in connectorfor power supply & FG
I/O display selector switch
Connector
Operating status display LEDs
DIN rail mounting hookThis hook is used to mount the
module on the DIN rail.
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
Station No. setting switch
PW
L RUN
L ERR
X0 to 1FY0 to 1F
LED name DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.Turns ON when a transmission error (CRC error) occurs and OFF when the timeout is reached (L RUN also goes out.)Turns ON due to incorrect station No. or transmission rate setting.Flashing when the station No. and/or transmission rate switch setting has been changed while the power is on.Indicates the input ON/OFF status. Indicator is ON when the input is ON, and is OFF when the input is OFF.
PWL RUN
L ERR
X0 to 1FY0 to 1F
LED DescriptionTurns ON when the remote I/O module is powered ON.Turns ON when normal data are received from the master station and goes OFF when the timeout is reached.Turns ON when a transmission error (CRC error) occurs and OFF when the timeout is reached (L RUN also goes out.)Turns ON due to incorrect station No. or transmission rate setting.Flashing when the station No. and/or transmission rate switch setting has been changed while the power is on.Indicates the input ON/OFF status. Indicator is ON when the input is ON, and is OFF when the input is OFF.
AJ65SBTCF1-32
79 80
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Output module
AJ65SBTCF1-32TUnit: mm
Input module
AJ65SBTCF1-32D
Unit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
FCN
FCN
I/O composite module
AJ65SBTCF1-32DT
Unit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
FCN
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external power
supply
Surge suppression
Wiring method for common
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point (when all point is on: 0.1A/
point) 1.6A/common
1.0A 10ms or less
0.1mA or lower
0.085V or lower (TYP) 0.1A, 0.2V or lower (TYP) 0.1A
Sink type
Protection against overload,
overvoltage and overheat
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
30mA or less (at TYP24VDC and all point is on)
Not including external load current
Zener diode
16 points/common
(40-pin connector, with all points ON)
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Description
32 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14V/3.5mA or higher
6V/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or or less (at 24VDC)
32 points/common (40-pin connector 1-wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
45mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
Description
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 3.2A/common
1.0A 10ms or less
0.1mA or lower
0.085V or lower (TYP) 0.1A, 0.2V
or lower (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (TYP.24VDC/common)
Not including external load current
Zener diode
32 points/common (40-pin connector 1-wire type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
60mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500 VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%
14V/3.5mA or higher
6V/1.7mA or lower
Approx. 4.7k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common (40-pin connector 1-wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.15
124124102040 8
ON
STATION NO. B RATEX0-XF
X10-X1F
X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM
11
20
7.9 DIN rail
(About 110°)
4 50
16
.5
118
MITSUBISHI AJ65SBTCF1-32D
109 (Mounting pitch)+1 0
2-4.5 x 5.1 mounting hole (M4 mounting screw)
124124102040 8
ON
STATION NO. B RATEX0-XF
X10-X1F
X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM
11
20
7.9 DIN rail
(About 110°)
4 50
16
.5
118
MITSUBISHI AJ65SBTCF1-32D
109 (Mounting pitch)+1 0
2-4.5 x 5.1 mounting hole (M4 mounting screw)
21 DA
DB3 DG4 SLD
DC DC5 +24V6 FG7 24G
B19B20 X0
X1B18 X2B17 X3B16 X4B15 X5B14 X6B13 X7B12 X8B11 X9B10 XAB9 XBB8 XCB7 XDB6 XEB5 XFA20 X10A19 X11A18 X12A17 X13A16 X14A15 X15A14 X16A13 X17A12 X18A11 X19A10 X1AA9 X1BA8 X1CA7 X1DA6 X1EA5 X1FB2 COMB1 COM
R
R
R
R
Insulation
Modulepower supply
I/O power supply
21 DA
DB3 DG4 SLD
DC DC5 +24V6 FG7 24G
B19B20 Y0
Y1B18 Y2B17 Y3B16 Y4B15 Y5B14 Y6B13 Y7B12 Y8B11 Y9B10 YAB9 YBB8 YCB7 YDB6 YEB5 YFA20 Y10A19 Y11A18 Y12A17 Y13A16 Y14A15 Y15A14 Y16A13 Y17A12 Y18A11 Y19A10 Y1AA9 Y1BA8 Y1CA7 Y1DA6 Y1EA5 Y1FB1,2CTL+A1,2COM
L
L
B1,2 CTL+A1,2 COM
L
Insulation
Module power supply
Load power supply
I/O powersupply(External power supply)
When common power supplyis used for I/O and loads.
Constant voltagecircuit
124124102040 8
ON
STATION NO. B RATEX0-XF
X10-X1F
X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC
X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM
11
20
7.9 DIN rail
(About 110°)
4 50
16
.5
118
MITSUBISHI AJ65SBTCF1-32D
109 (Mounting pitch)+1 0
2-4.5 x 5.1 mounting hole (M4 mounting screw)
Module power supply
DC DC
Insulation
DADBDGSLD+24VFG24G
21
34567
RR
RR
L
L
Constant voltage circuit
I/O Module power supply(External power supply)
When common power supplyis used for I/O and loads.
A3A,B1A,B2
Y1FCTL+COM-
B19B20 X0
X1B18 X2B17 X3B16 X4B15 X5B14 X6B13 X7A20 X8A19 X9A18 XAA17 XBA16 XCA15 XDA14 XEA13 XFA,B12 COMA,B11 NCB10 Y10B9 Y11B8 Y12B7 Y13B6 Y14B5 Y15B4 Y16B3 Y17A10 Y18A9 Y19A8 Y1AA7 Y1BA6 Y1CA5 Y1DA4 Y1EA3 Y1FA,B1 CTL+A,B2 COM-
I/O Module power supply
L
B1
(CO
M)
B2
(CO
M)
B3
(Em
pty)B
4(E
mpty)
B5
(XF
)B
6(X
E)
B7
(XD
)B
8(X
C)
B9
(XB
)B
10(X
A)
B11
(X9)
B12
(X8)
B13
(X7)
B14
(X6)
B15
(X5)
B16
(X4)
B17
(X3)
B18
(X2)
B19
(X1)
B20
(X0)
A1 (E
mpty)
A2 (E
mpty)
A3 (E
mpty)
A4 (E
mpty)
A5
(X1F
)A
6(X
1E)
A7
(X1D
)A
8(X
1C)
A9
(X1B
)A
10(X
1A)
A11
(X19)
A12
(X18)
A13
(X17)
A14
(X16)
A15
(X15)
A16
(X14)
A17
(X13)
A18
(X12)
A19
(X11)
A20
(X10)
B1
(CT
L+)
B2
(CO
M-)
B3
(Y17)
B4
(Y16)
B5
(Y15)
B6
(Y14)
B7
(Y13)
B8
(Y12)
B9
(Y11)
B10
(Y10)
B11 (E
mpty)
B12
(CO
M)
B13
(X07)
B14
(X06)
B15
(X05)
B16
(X04)
B17
(X03)
B18
(X02)
B19
(X01)
B20
(X00)
A1
(CT
L+)
A2
(CO
M-)
A3
(Y1F
)A
4(Y
1E)
A5
(Y1D
)A
6(Y
1C)
A7
(Y1B
)A
8(Y
1A)
A9
(Y19)
A10
(Y18)
A11 (E
mpty)
A12
(CO
M)
A13
(X0F
)A
14(X
0E)
A15
(X0D
)A
16(X
0C)
A17
(X0B
)A
18(X
0A)
A19
(X09)
A20
(X08)
B1
(CT
L+)
B2
(CT
L+)
B3
(Em
pty)B
4(E
mpty)
B5
(Y0F
)B
6(Y
0E)
B7
(Y0D
)B
8(Y
0C)
B9
(Y0B
)B
10(Y
0A)
B11
(Y09)
B12
(Y08)
B13
(Y07)
B14
(Y06)
B15
(Y05)
B16
(Y04)
B17
(Y03)
B18
(Y02)
B19
(Y01)
B20
(Y00)
A1
(CO
M-)
A2
(CO
M-)
A3
(Em
pty)A
4 (Em
pty)A
5(Y
1F)
A6
(Y1E
)A
7(Y
1D)
A8
(Y1C
)A
9(Y
1B)
A10
(Y1A
)A
11(Y
19)A
12(Y
18)A
13(Y
17)A
14(Y
16)A
15(Y
15)A
16(Y
14)A
17(Y
13)A
18(Y
12)A
19(Y
11)A
20(Y
10)
40
40
40
81 82
Remote I/O modulesProduct information
40-pin connector type (FCN connector type)40-pin
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts32 -wire124VDC
Protection
-wire10.1A
DC input
pts16 -wire124VDC Protection
-wire10.1A
Transistoroutput
pts32
Transistoroutput
pts16
I/O composite module
AJ65SBTCF1-32DT1
Unit: mm
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
FCN
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area external
power supply
Surge suppression
Wiring method for common
Description
16 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A
Sink type
Protection against overload,
overvoltage and overheat
1ms or less
1ms or less (Rated load, resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
10mA or lower (at 24VDC, with all point ON)
Zener diode
16 points/common (40-pin connector 1-wire type)
MemoMemoMemoExternal dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Description
16 points
Photocoupler
24VDC
Approx. 5mA
19.2 to 26.4VDC (ripple ratio: within 5%)
100%/60%
15V/3mA or higher
3V/0.5mA or lower
Approx. 4.7k
0.2 ms or less (at 24VDC)
0.2 ms or less (at 24VDC)
16 points/common (40-pin connector 1-wire type)
Positive/Negative common shared type
(Sink/source shared type)
Assignment of 32 points/station (32 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
50mA or lower
(TYP. 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to
60Hz frequency
500VAC across all DC external terminals
and ground for 1 min
10M or higher, between DC external
terminals and ground by a 500VDC
insulation resistance tester
0.1611
5
41 67
CON.A CON.B
PW
LINK X0
XF
CON.C CON.D
PW/AUX.
L RUN
L ERR
0 1 2 3 4 5 6 7
8 9 A B C D E F
Y10
Y1F
AJ65VBTCF1-32DT1
46
16.5
31
12345
12345
DADBDGNCSLD
LINKCABLE(IN)
Push-in connectorfor communication
CON.A
12345
12345
DADBDGNCSLD
LINKCABLE(OUT)
UNIT POWER CABLE (IN)
I/O POWER CABLE (IN)
UNIT POWERCABLE (OUT)I/O POWERCABLE (OUT)
CON.B
12345
12345
FG+24V(UNIT) 24G(UNIT)
NC NC
Push-in connector for power supply & FG
I/O power supply
B3, A3B1, A1B2, A2
B3, A3
B10, A10
B12, A12
B13, A13
CON1
B20, A20CON1
B1, A1
B2, A2I/O power supply(External power supply)
When common power supply is used for I/O and loads.
CON.C
12345
12345
FG+24V(UNIT) 24G(UNIT)
NC NC
CON.D
DC DC
Insulation
L
L
L
Constant voltage circuit
R
R
R
R
A20 (X08)A19 (X09)A18 (X0A)A17 (X0B)A16 (X0C)A15 (X0D)A14 (X0E)A13 (X0F)A12 (COM)A11 (Empty)A10 (Y18)A9 (Y19)A8 (Y1A)A7 (Y1B)A6 (Y1C)A5 (Y1D)A4 (Y1E)A3 (Y1F)A2 (COM-)A1 (CTL+)
B20 (X00)B19 (X01)B18 (X02)B17 (X03)B16 (X04)B15 (X05)B14 (X06)B13 (X07)B12 (COM)B11 (Empty)B10 (Y10)B9 (Y11)B8 (Y12)B7 (Y13)B6 (Y14)B5 (Y15)B4 (Y16)B3 (Y17)B2 (COM-)B1 (CTL+)
1 (DA)
2(DB)
3(DG)
4(Empty)
5 (SLD)
CONA CONB
CONC COND
1(FG)
2(+24V)
3(24G)
4(Empty)
5(Empty)
Refer to the derating curve on the left for the input deration of the orientations other than Front mounting (Basic orientation).
[%]
[˚C]
Ambient temperature [°C]
Derating curve
[%]
100
0 10 20 30 40 5545
60
50
Max
. sim
ulta
neou
sin
put p
oint
s
83 84
Remote I/O modulesProduct information
40-pin connector type (FCN connector type)40-pin
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts16 -wire124VDC Protection
-wire10.1A
Transistoroutput
pts16High speed
input
Waterproof connector type
Overview
Part names and functions
Features
Waterproof connector typeWaterproof
Communication connector Pin-out
Power supply connector
* The actual modules may slightly differ in shapes from the photos shown.
The waterproof type modules are compliant with IP67
protection rating.
Modules can e replaced without stopping the system.
Easy connections are available without tools, saving
the labor time and cost.
Terminating resistors are built in the modules.
(switching between 110 and 130 )
The modules are mountable in 6 different orientations.
ON
40 10 4 1 220 8 2 4 1STATION NO B RATE
Communication adapter (frontside)
Connector
Communication adapter (back)
Connector
ON
TERMINATION110Ω 130Ω
AJ65FBTA42-16DTE
PROTECTY8Y9YAYBYCYDYEYF
Y
Y
Y
Y
Y
Y
Y
Y
Communicationadapter
Operation status LEDs
Waterproof connector for power supply line
Transmission rate setting switch
Waterproof connector for I/O
FG metal fittings
Waterproof connector for transmission line
Terminal resistor setting
OFFONOFFON
OFFOFFONON
DIP switch1 DIP switch2 Description
DetailsLED namePOWERL RUNL ERR.
PROTECT
X0 to FY0 to F
ON: Power is ON.ON: Communication is normal.OFF: Communication is normal.OFF: NormalON: Protective function is active.Indicates the input ON/OFF status.Turns ON or OFF when the input is ON or OFF respectively.
Station No. setting switchSet the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Setting value Transmission rate
View from module front
23
14
LINK INMale
214 35
LINK OUT Female
Male
Female
UNIT POWER AUX.
2 143 5
Male
2 143 5
214 35
I/O connector
Pin No.
1
2
3
4
5
LINK IN
SLD
DB
DG
DA
No pins
LINK OUT
SLD
DB
DG
DA
Vacant
Pin No.
1
2
3
4
5
UNIT POWER
+24V(UNIT)
Vacant
24G(UNIT)
Vacant
FG
AUX
+24V(I/O)
Vacant
24G(I/O)
Vacant
FG
No terminal resistor110 resistor ON130 resistor ONSetting prohibited
85 86
Remote I/O modulesRemote I/O modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Input module
AJ65FBTA4-16DE
Unit: mm
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method
for common
Input form
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Negative common
(Source type)
Output module
AJ65FBTA2-16TE
Unit: mm
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop
at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
1.0A/1point, 4.0A/common
2.0A 10ms or lower
0.3mA or lower
0.15V or lower (TYP) 1.0A,
0.2V or lower (MAX) 1.0A
Negative common
(Source type)
Overheat/short-circuit
protection
(LED turns ON upon
activation)
30mA or lower
Waterproof
Input module
AJ65FBTA4-16D Waterproof
to
Waterproof
Output module
AJ65FBTA2-16TWaterproof
Waterproofto
AJ65FBTA4-16D
Input specificationsDescription
AJ65FBTA4-16D AJ65FBTA4-16DEOutput specifications
Description
AJ65FBTA2-16T AJ65FBTA2-16TE
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X1
24G
X0
Vacant
+24V
X3
24G
X2
Vacant
+24V
X5
24G
X4
Vacant
+24V
X7
24G
X6
Vacant
X0--
X1
Pin No. Signal name
X2--
X3
X4--
X5
X6--
X7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X9
24G
X8
Vacant
+24V
XB
24G
XA
Vacant
+24V
XD
24G
XC
Vacant
+24V
XF
24G
XE
Vacant
X8--
X9
Pin No. Signal name
XA--
XB
XC--
XD
XE--
XF
AJ65FBTA4-16DE
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X1
24G
X0
Vacant
+24V
X3
24G
X2
Vacant
+24V
X5
24G
X4
Vacant
+24V
X7
24G
X6
Vacant
X0--
X1
Pin No. Signal name
X2--
X3
X4--
X5
X6--
X7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X9
24G
X8
Vacant
+24V
XB
24G
XA
Vacant
+24V
XD
24G
XC
Vacant
+24V
XF
24G
XE
Vacant
X8--
X9
Pin No. Signal name
XA--
XB
XC--
XD
XE--
XF
AJ65FBTA2-16T
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
Y1
Vacant
Y0
Vacant
+24V
Y3
Vacant
Y2
Vacant
+24V
Y5
Vacant
Y4
Vacant
+24V
Y7
Vacant
Y6
Vacant
Y0--
Y1
Pin No. Signal name
Y2--
Y3
Y4--
Y5
Y6--
Y7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
Y9
Vacant
Y8
Vacant
+24V
YB
Vacant
YA
Vacant
+24V
YD
Vacant
YC
Vacant
+24V
YF
Vacant
YE
Vacant
Y8--
Y9
Pin No. Signal name
YA--
YB
YC--
YD
YE--
YF
AJ65FBTA2-16TE
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Vacant
Y1
24G
Y0
Vacant
Vacant
Y3
24G
Y2
Vacant
Vacant
Y5
24G
Y4
Vacant
Vacant
Y7
24G
Y6
Vacant
Y0--
Y1
Pin No. Signal name
Y2--
Y3
Y4--
Y5
Y6--
Y7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Vacant
Y9
24G
Y8
Vacant
Vacant
YB
24G
YA
Vacant
Vacant
YD
24G
YC
Vacant
Vacant
YF
24G
YE
Vacant
Y8--
Y9
Pin No. Signal name
YA--
YB
YC--
YD
YE--
YF
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
16 points
Photocoupler
24VDC
Approx. 7mA
20.4 to 26.4VDC (ripple ratio: within 5%)
100%
14V/3.5mA or higher
6V/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
16 points/common
(waterproof connector 2 to 4-wire type)
Positive common
(Sink type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple ratio: within 5%)
40mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of 500Vp-p,
noise width 1µs and 25 to 60Hz frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher across DC external terminals and
ground by a 500VDC insulation resistance tester
0.40
16 points
Photocoupler
12 to 24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.5A/point, 4.0A/common
1.0A 10ms or lower
0.25mA or lower
0.15V or lower (TYP) 0.5 A,
0.25V or lower (MAX) 0.5 A
Positive common
(Sink type)
Overheat/short-circuit
protection
0.5ms or less
1.5ms or less (Resistive load)
10.2 to 28.8VDC (ripple ratio: within 5%)
20mA or lower
(At 24VDC, with all points ON)
Not including external load current
Zener diode
16 points/common (waterproof connector 2-wire type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
50mA or lower (at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher across DC external terminals and
ground by a 500VDC insulation resistance tester
0.40
6050±1
26.518.3
21.3
6824
25
200
M4 mounting screw
192±
1
4.135
4.3
Two 4.5mm x 6mm oblong holesfor M4 mounting screws
48
34±0.5
21.732
Label
33
+10
+1 0
2525
6
6
6050±1
26.518.3
21.3
6824
25
200
M4 mounting screw
192±
1
4.135
4.3
Two 4.5mm x 6mm oblong holesfor M4 mounting screws
48
34±0.5
21.732
Label
33
+10
+1 0
2525
6
6
R
R
R
R
R
R
R
R
R
R
R
R
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
RR
110Ω
130Ω
Communicationcircuit
DC/DC31
25
4
24
31
5
AUX.
Unit mountingscrew (FG)
31
25
44-wire sensor (Sink output)
3-wire sensor (Sink output)
2-wire sensor (Sink output)
24
31
5
24
31
5
I/O connector
Terminal resistance setting switch
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
RR
110Ω
130Ω
31
25
4
Terminal resistance setting switch
AUX.
Unit mountingscrew (FG)
31
25
4
I/O connector
Communicationcircuit
DC/DC
L
L
Load
24
31
5
L
L
Load
24
31
5
L
L
Load
24
31
5
Constant voltage circuit
Detec
tion c
ircuit
Detec
tion c
ircuit
Detec
tion c
ircuit
Unit mountingscrew (FG)
4-wire sensor (Sink output)
3-wire sensor (Sink output)
2-wire sensor (Sink output)
Terminal resistance setting switch
R
R
R
R
R
R
R
R
R
R
R
R
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
RR
110Ω
130Ω
DC/DC31
25
4
24
31
5
AUX.
31
25
4
24
31
5
24
31
5
I/O connector
Detec
tion c
ircuit
Detec
tion c
ircuit
Detec
tion c
ircuit
Terminal resistance setting switch
Unit mountingscrew (FG)
I/O connector
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
RR
110Ω
130Ω
31
25
4
AUX.
31
25
4
DC/DC
L
L
Load
24
31
5
L
L
Load
24
31
5
L
L
Load
24
31
5
AJ65FBTA2-16T
AJ65FBTA2-16TE
AJ65FBTA4-16D
AJ65FBTA4-16DE
Communicationcircuit
Communicationcircuit
Constant voltage circuit
87 88
Remote I/O modulesProduct information
Waterproof connector type
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
DC input
pts16 -wire224VDC
-wire424VDC
DC input
pts16 -wire224VDC
-wire424VDC
Protection
-wire20.5A
Protection
-wire21.0A
Transistoroutput
pts16
Transistoroutput
pts16
I/O composite module
AJ65FBTA42-16DTE
Unit: mm
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method
for common
Input form
No. of stations occupied
I/O module
power
supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
Negative common
(Source type)
45mA or lower
Waterproof
I/O composite module
AJ65FBTA42-16DT
to
Waterproof
to
Waterproof
AJ65FBTA42-16DT
Input specificationsDescription
AJ65FBTA42-16DT AJ65FBTA42-16DTE
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X1
24G
X0
Vacant
+24V
X3
24G
X2
Vacant
+24V
X5
24G
X4
Vacant
+24V
X7
24G
X6
Vacant
X0--
X1
Pin No. Signal name
X2--
X3
X4--
X5
X6--
X7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
Y9
Vacant
Y8
Vacant
+24V
YB
Vacant
YA
Vacant
+24V
YD
Vacant
YC
Vacant
+24V
YF
Vacant
YE
Vacant
Y8--
Y9
Pin No. Signal name
YA--
YB
YC--
YD
YE--
YF
AJ65FBTA42-16DTE
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
+24V
X1
24G
X0
Vacant
+24V
X3
24G
X2
Vacant
+24V
X5
24G
X4
Vacant
+24V
X7
24G
X6
Vacant
X0--
X1
Pin No. Signal name
X2--
X3
X4--
X5
X6--
X7
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Vacant
Y9
24G
Y8
Vacant
Vacant
YB
24G
YA
Vacant
Vacant
YD
24G
YC
Vacant
Vacant
YF
24G
YE
Vacant
Y8--
Y9
Pin No. Signal name
YA--
YB
YC--
YD
YE--
YF
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop
at ON
Output form
Protective function
Response
time
Output area
external power
supply
Surge suppression
Wiring method for common
8 points
Photocoupler
24VDC
20.4 to 26.4VDC (ripple ratio: within 5%)
0.5A/point, 2.4A/common
1.0A 10ms or lower
0.25 mA or lower
0.15V or lower (TYP) 0.5A,
0.25V or lower (MAX) 0.5A
Positive common
(Sink type)
Overheat protection,
short protection
0.5ms or less
1.5ms or less (Resistive load)
20.4 to 26.4VDC (ripple ratio: within 5%)
10mA or lower (at 24VDC, with all points ON)
Not including external load current
Zener diode
8 points/common (waterproof connector 2-wire type)
1.0A/1point, 4.0A/common
2.0A 10ms or lower
0.3 mA or lower
0.15V or lower (TYP) 1.0A,
0.2V or lower (MAX) 1.0A
Negative common
(Source type)
Overheat protection,
short protection
(LED lights when protect
function is activated)
Output specificationsDescription
AJ65FBTA42-16DT AJ65FBTA42-16DTE
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
8 points
Photocoupler
24VDC
Approx. 7mA
20.4 to 26.4VDC (ripple ratio: within 5%)
100%
14V/3.5mA or higher
6V/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
8 points/common
(waterproof connector 2- to 4-wire type)
Positive common
(Sink type)
Assignment of 32 points/station (16 points used)
20.4 to 26.4VDC (ripple rate: within 5%)
500mA or lower
(at 24VDC, with all points ON)
Tested by a DC type noise simulator of
500Vp-p, noise width 1µs and 25 to 60Hz
frequency
500VAC across all DC external terminals
and ground for 1min
10M or higher, between DC external terminals and
ground by a 500VDC insulation resistance tester
0.40
6050±1
26.518.3
21.3
6824
25
200
M4 mounting screw
192±
1
4.135
4.3
Two 4.5mm x 6mm oblong holesfor M4 mounting screws
48
34±0.5
21.732
Label
33
+10
+1 0
2525
6
6
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
R110Ω
130Ω
31
25
4
24
31
5
AUX.
Unit mountingscrew (FG)
31
25
44-wire sensor (Sink output)
24
31
5
I/O connector
R
R
R
R
R
R
R
R
R
R
R
R24
31
5
Communicationcircuit
DC/DC
L
L
Load
24
31
5
Terminal resistance setting switch
R
3-wire sensor (Sink output)
2-wire sensor (Sink output)
Dete
ctio
ncir
cuit
Dete
ctio
ncir
cuit
Dete
ctio
ncir
cuit Co
nsta
nt vo
ltage
circu
it
LINK IN
24
13
LINK OUT
24
13
5
UNIT POWER
RR
110Ω
130Ω
31
25
4
Terminal resistance setting switch
24
31
5
AUX.
Unit mountingscrew (FG)
31
25
4
24
31
5
R
R
R
R
R
R
R
R
R
R
R
R24
31
5
DC/DC
L
L
Load
24
31
5
I/O connector4-wire sensor (Source output)
3-wire sensor (Source output)
2-wire sensor (Source output)
AJ65FBTA42-16DT
AJ65FBTA42-16DTE
Communicationcircuit
Cons
tant
volta
gecir
cuit
Dete
ctio
ncir
cuit
Dete
ctio
ncir
cuit
Dete
ctio
ncir
cuit
89 90
Remote I/O modulesProduct information
Waterproof connector type
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
DC input
pts8 -wire224VDC
-wire424VDC
Protection
-wire20.5A
DC input
pts8 -wire224V DC
-wire424V DC
Protection
-wire21.0A
Transistoroutput
pts8
Transistoroutput
pts8
MemoMemoMemo
All of the following types operate as remote device stations. The optimum module for your application can be selected from a wide variation of the products.
Overview
Screw T. block
Screw T. block
AJ65VBTCU-68ADVN
AJ65VBTCU-68ADIN
AJ65VBTCU-68DAVN
AJ65SBT-64AD
AJ65BT-64AD
AJ65BT-64RD3
AJ65BT-64RD4
AJ65BT-68TD
AJ65SBT-62DA
AJ65BT-64DAV
AJ65BT-64DAI
Voltage input
Current input
Voltage output
Voltage/current input
Temperatureinput
Voltage output
Current output
95
95
96
99
103
105
105
105
100
104
104
Features Page
Model names
ModelProduct name
Push-inconnectortype
Screwterminal block type
Voltage/current output
Push-in connector type
Screw/2-piece terminal block type
Screw terminal block type
P.101
P.93 P.97Push-in
st.s1/3Occupied
CH8Channel Push-in
st.s1/3Occupied
CH8Channel Push-in
st.s1/3Occupied
CH8Channel Push-in
st.1Occupied
CH4Channel Screw T. block
st.s2Occupied
CH4Channel Screw T. block
st.s2Occupied
CH4Channel Screw T. block
st.s4Occupied
CH8Channel Screw T. block
st.s4Occupied
CH4Channel Screw T. block
st.s4Occupied
CH4Channel Screw T. block
st.s2Occupied
CH4Channel Screw T. block
st.1Occupied
CH2Channel Screw T. block
91 92
Analog modulesAnalog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Push-in connector type
Overview
Part names and functions
Features
Push-in connector typePush-in
AJ65VBTCU-68ADVN/AJ65VBTCU-68ADIN
AJ65VBTCU-68DAVN
Easy wiring with push-in connector
Supports CC-Link Ver.2
Operation status LEDs
Communication connectorSELECT/SET switch
Mode select switch
Station No. setting switch
Offset/gain adjusting LEDs
DescriptionAJ65VBTCU-68ADVN AJ65UBTCU-68ADIN
0: Normal mode1: Test mode(User range setting 1)2: Test mode(User range setting 2)
3: Normal mode4: Test mode(User range setting 1)5: Test mode(User range setting 2)6 to 7: Prohibited
Ver. 1 mode Ver. 2 mode0: Normal mode1: Test mode(User range setting)
3: Normal mode4: Test mode(User range setting)2, 5 to 7: Prohibited
Ver. 1 mode Ver. 2 mode
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
DescriptionLED namePOWER
RUN
L RUNL ERR.
ON: Power is turn on.Normal mode
Test mode
ON: When communication is normal.OFF: When communication is failed.
ON: Normal operationON: The SELECT/SET switch is set to SET.OFF: The SELECT/SET switch is set to SELECT or
center position.
Pin No.54321
SignalSLDNCDGDBDA
Connector pin No.
Connector pin No.
Connector for power supplyPin No.
54321
SignalFG1AG
24G(UNIT)+24V(UNIT)
FG
Connector for analog inputPin No.
4321
SignalSLDNCV-/I-V+/I+
Connector pin No.
4 3 2 1 Transmission rate setting switch
Operation status LEDs
Communication connectorSELECT/SET switch
Mode select switch
Station No. setting switch
Offset/gain adjusting LEDs
DescriptionAJ65VBTCU-68DAVN
0: Normal mode1: Test mode (User range setting 1)2: Test mode (User range setting 2)
3: Normal mode4: Test mode (User range setting 1)5: Test mode (User range setting 2)6 to 7: Prohibited
Ver. 1 mode Ver. 2 mode
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.Make sure that the setting is within the range of 1 to 64.
DescriptionLED namePOWER
RUN
L RUNL ERR.
ON: Power is turn on.Normal mode
Test mode
ON: When communication is normal.OFF: When communication is failed.
ON: Normal operationON: The SELECT/SET switch is set to SET.OFF: The SELECT/SET switch is set to SELECT or
center position.
Pin No.54321
SignalSLDNCDGDBDA
Connector pin No.
Connector for power supplyPin No.
54321
SignalNCNC
24G(UNIT)+24V(UNIT)
FG
Connector for analog outputPin No.
4321
SignalNC
COMNCV+
4 3 2 1 Transmission rate setting switch
12345
12345
Connector pin No.
12345
12345
01234
Settingvalue
Transmissionrate
156kbps625kbps2.5Mbps5Mbps10Mbps
01234
Settingvalue
Transmissionrate
156kbps625kbps2.5Mbps5Mbps
10Mbps
93 94
Analog modulesAnalog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Push-inPush-in
Push-in
Voltage input module
AJ65VBTCU-68ADVN
Unit: mm
Current input module
AJ65VBTCU-68ADIN
AJ65VBTCU-68ADVNInput specifications
AJ65VBTCU-68ADIN
Analog input
Digital value
I/O characteristics
Input range switching
Offset/gain setting
Maximum conversion speed
Absolute maximum input
Analog input points
Station type
Number of stations occupied
Expanded cyclic setting
CC-Link-compatible function
Withstand voltage
Isolation method
External wiring system
Applicable
wire size
Applicable DIN rail
External power supply
Inrush current
Internal current consumption (24VDC)
Weight (kg)
Push-in connector for
communication
Push-in connector
for power supply
Push-in connector for
analog I/O
AJ65VBTCU-68ADVN
Voltage
AJ65VBTCU-68ADIN
Current
-10 to +10V
User range setting 1
(-10 to +10V)
0 to 5V
1 to 5V
User range setting 2
(0 to +5V)
0 to 20mA
4 to 20mA
User range setting
(0 to 20mA)
-4000 to +4000
0 to 4000
0 to 4000
±0.3%
(±12digit*)
±0.2%
(±8digit*)
2.5mV
1.25mV
1.0mV
1.0mV
5µA
4µA
4µA
Analog input range Ambient temperature
0 to 55°C
Ambient temperature
25±5°CDigital value
Maximumresolution
Accuracy
Push-in connector for communication [Transmission circuit] (5-pin press-fitting type, connector plugs are sold separately)
Push-in connector for power supply/FG [Module power supply and FG] (5-pin press-fitting type, connector plugs are sold separately)
Push-in connector for analog input (4-pin press-fitting type, connector plugs are sold separately)
<Optional parts> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P
Voltage
Current
*: 1digit refers to one digital unit.
* Accuracy (accuracy relative to the maximum digital output value)
Voltage output module
AJ65VBTCU-68DAVN
Unit: mm
Output specifications
Digital input value
Analog output
I/O characteristics
Accuracy
(accuracy relative to the
maximum digital output value)
Output range switching
Offset/gain setting
Maximum conversion speed
Output short-circuit protection
Absolute maximum output
Analog output points
Station type
Number of stations occupied
Expanded cyclic setting
CC-Link-compatible function
Isolation method
External wiring system
Applicable
wire size
Applicable DIN rail
External power supply
Inrush current
Internal current consumption
Weight (kg)
Voltage
-10 to +10VUser range setting 1
(-10 to +10V)
0 to 5V1 to 5V
User range setting 2
(0 to 5V)
-4000 to +4000
0 to 4000
2.5mV
1.25mV1.0mV
1.0mV
Analog output Ambient temperature
0 to 55°C
±0.3%(±30mV)
±0.3%(±15mV)
Ambient temperature
25±5°C
±0.2%(±20mV)
±0.2%(±10mV)
Digital input value Maximumresolution
Accuracy
Push-in connector for
communication
Push-in connector
for power supply
Push-in connector for
analog I/O
Push-in connector for communication [Transmission circuit] (5-pin press-fitting type, connector plugs are sold separately)
Push-in connector for power supply/FG [Module power supply and FG] (5-pin press-fitting type, connector plugs are sold separately)
Push-in connector for analog input (4-pin press-fitting type, connector plugs are sold separately)
<Optional parts> Online connector for communication: A6CON-LJ5P Online connector for power supply: A6CON-PWJ5P
st.s1/3Occupied
CH8Channel
st.s1/3Occupied
CH8Channel
st.s1/3Occupied
CH8Channel External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specificationsDescriptions
-10 to +10VDC (input resistance 1M )_
16-bit signed binary (-4096 to +4095)
Voltage: ±15v
_
0 to 20mA DC (input resistance 250 )
16-bit signed binary (-96 to +4095)
Current: ±30mA
For each channel
Provided
1ms/channel
8 channels/module
Remote device station
3 Ver.1-mode station (RWr/RWw: 12 words each, RX/RY: 32 points)
1 Ver.2-mode station (Extended 16 words each (Wr/RWw), RX/RY: 32 points), quadruple setting
Cyclic transmission, extended cyclic transmission, reduction in station-to-station cable length
Between batch of power supply/communication systems and batch of analog inputs: 500 VAC for one minute
Across communication system terminals and all analog input terminals: Photocoupler isolation, Across power supply system terminals and all analog input terminals: Photocoupler isolation
Between channels: No isolation, Communication interface: Not isolated
Communication line: Ver. 1.10 compatible CC-Link dedicated cable 0.5mm2 (AWG20) [ 2.2 to 3.0],
shielded wire 0.5mm2 (AWG20)
0.66 to 0.98mm2 (AWG18) [ 2.2 to 3.0] wire diameter 0.08 mm2 or more
1.0 to 1.4 (A6CON-P214), 1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm2]
1.0 to 1.4 (A6CON-P514), 1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.3 mm2]
TH35-7.5Fe, TH35-7.5Al (conforming to JIS-C2812)
CC-Link connector type metal installation fitting : A6PLT-J65V1
24VDC (20.4 to 26.4VDC ripple ratio : within 5%)
4.2A, 1.2 ms or less
0.10A
0.17
Descriptions
16-bit signed binary (-4096 to +4095)
-10 to +10VDC (external load resistance: 2k to 1M )
For each channel
Provided
1ms/channel
Provided
±12V
8 channels/module
Remote device station
3 Ver.1-mode stations (RWr/RWw: 12 words each, RX/RY: 32 points)
1 Ver.2-mode stations (Extended 16 words each (Wr/RWw), RX/RY: 32 points), quadruple setting
Cyclic transmission, extended cyclic transmission, reduction in station-to-station cable length
Across communication system terminals and all analog output terminals: Photocoupler isolation
Across power supply system terminals and all analog output terminals: Photocoupler isolation
Between channels: No isolation
Communication line: Ver. 1.10 compatible CC-Link dedicated cable 0.5mm2 (AWG20) [ 2.2 to 3.0],
shielded wire 0.5mm2 (AWG20)
0.66 to 0.98mm2 (AWG18) [ 2.2 to 3.0] wire diameter 0.08 mm2 or more
1.0 to 1.4 (A6CON-P214), 1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm2]
1.0 to 1.4 (A6CON-P514), 1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.3 mm2]
TH35-7.5Fe, TH35-7.5Al (conforming to JIS-C2812)
CC-Link connector type metal installation fitting: A6PLT-J65V1
24VDC (20.4 to 26.4VDC ripple ratio: within 5%)
4.3A, 1.2 ms or less
0.15A
0.16
*1 Use a 2-core twisted shield wire.*2 Indicates input resistance of the AJ65VBTCU-68ADIN.*3 Be sure to ground FG1. AG should be also grounded in the case of
frequent noise.The offset and gain values must be set again if the ground wiring (grounded or not) is changed after setting the values.
*2
*3
*1 Shield
*1 Shield
AJ65VBTCU-68ADVN (Voltage input)
AJ65VBTCU-68ADIN (Current input)
Signal source 0 to ± 10V
Signal source 0 to ± 20mA
CH1
CH8
+15V
-15VGND
GND
1234
V+V-NCSLD
1234
I+I-NCSLD
AG
FG1
115
41 67
DIN
rai
l
(3.5)
57.5
57.5
31*16.5
*: It is 14.5mm when an online connector is not connected.
*1 Use a 2-core twisted shield wire.*2 Connect a capacitor of around 0.1 to 0.47 µF (it must be a able to
withstand voltages of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring.
115
41 67
DIN
rai
l
(3.5)
57.5
57.5
31*16.5
*: It is 14.5mm when an online connector is not connected.
D/Aconversion
CH1
CH8
*1 *2
Motor drivemodule, etc.
GND
Motor drivemodule, etc.
to
to
GND
V+NCCOMNC
1234
V+NCCOMNC
1234
500k
500k
500k250k
500k
2k
1M
2k
1M
95 96
Analog modulesProduct information
Push-in connector typePush-in
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Screw terminal block type
Overview
Part names and functions
Features
Screw terminal block typeScrew T. block
The use of self-up screws has reduced wiring works.
(No need to remove terminal screws when wiring
round solderless terminals)
The "finger protect" design allows direct installation to
machines.
AJ65SBT-64AD
AJ65SBT-62DA
LED name Details
Operation status LEDs
Offset/gain adjusting LEDs
PWRUN
L RUNL ERR.
LED name Description Station number setting switch
1234:
1011:
64
40OFFOFFOFFOFF
:OFFOFF
:ON
20OFFOFFOFFOFF
:OFFOFF
:ON
10OFFOFFOFFOFF
:ONON
:OFF
8OFFOFFOFFOFF
:OFFOFF
:OFF
4OFFOFFOFFON
:OFFOFF
:ON
2OFFONONOFF
:ONON
:OFF
1ONOFFONOFF
:OFFON
:OFF
Station Number
01234
Tens Units
Transmission rate setting switch
Settingvalue
Setting switch Transmissionrate4
OFFOFFOFFOFFON
2OFFOFFONONOFF
1OFFONOFFONOFF
156kbps625kbps2.5Mbps5Mbps
10Mbps
DIN rail hookUsed to mount the module to the DIN rail.
Terminal blockTerminal block for connection to the module power supply, transmission and I/O signal lines.
SELECT/SET switchON: Power is turn on.Normal mode
Test mode
ON: When communication is normal.ON: Indicates that transmission speed
setting or station number setting is outside of the range.
Normal modeTest mode
Always OFF
A lit LED is changed in turn each time the SELECT/SET switch is set to SELECT.
Normal operation 0.1s intervals Input range setting error.24VDC power failure or watchdog timer error occurred.The SELECT/SET switch is set to SET.0.1s intervals: Input range setting is not set to any of “user range setting 1 to 3”
0.5s intervals:The offset/gain setting is out of the setting range
ON:Flashing:
OFF:
ON:
Flashing:
CHOFFSETGAIN
PW RUN L RUN L ERR. CH1 2 OFFSET GAIN
MITSUBISHI AJ65SBT-64AD
DA DG +24V 24GDB SLD (FG)
TESTTEST V+ I+
AGV+ I+CH1 CH2
SELECT
SET
STATION NO. B RATE40 20 10 8 4 2 1 4 2 1 ON
3 4
(FG1)
COMSLDCOMV+ I+
V+ I+COMSLDCOM
CH3 CH4
LED name Details
Operation status LEDs
Offset/gain adjusting LEDs
PWRUN
L RUNL ERR.
LED name Description Station number setting switch
1234:
1011:
64
40OFFOFFOFFOFF
:OFFOFF
:ON
20OFFOFFOFFOFF
:OFFOFF
:ON
10OFFOFFOFFOFF
:ONON
:OFF
8OFFOFFOFFOFF
:OFFOFF
:OFF
4OFFOFFOFFON
:OFFOFF
:ON
2OFFONONOFF
:OFFOFF
:OFF
1ONOFFONOFF
:OFFON
:OFF
Station Number
01234
Tens Units
Transmission rate setting switch
Settingvalue
Setting switch Transmissionrate4
OFFOFFOFFOFFON
2OFFOFFONONOFF
1OFFONOFFONOFF
156kbps625kbps2.5Mbps5Mbps10Mbps
DIN rail hookUsed to mount the module to the DIN rail.
Terminal blockTerminal block for connection to the module power supply, transmission and I/O signal lines.
SELECT/SET switch
UP/DOWN switchON: Power is turn on.Normal mode
Test mode
ON: When communication is normal.ON: Indicates that transmission speed
setting or station number setting is outside of the range.
Normal modeTest mode
Always OFF
A lit LED is changed in turn each time the SELECT/SET switch is set to SELECT.
Normal operation 0.1s intervals Output range setting error.24VDC power failure or watchdog timer error occurred.The SELECT/SET switch is set to SET.0.1s intervals: Output range setting is not set to any of “user range setting 1 to 3”
0.5s intervals:The offset/gain setting is out of the setting range
ON:Flashing:
OFF:
ON:
Flashing:
CHOFFSETGAIN
PW RUN L RUN L ERR. CH1 2 OFFSET GAIN
MITSUBISHI AJ65SBT-62DA
DA DG +24V 24GDB SLD (FG)
TESTTEST NC NC NC
NCNC I+CH1 CH2
UP
DOWN
SELECT
SET
STATION NO. B RATE40 20 10 8 4 2 1 4 2 1 ON
NCI+V+NC I+
V+ NCNCCOMNC
97 98
Analog modulesAnalog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Voltage/current output module
AJ65SBT-62DA
Unit: mm
st.1Occupied
CH2Channel Screw T. block
Digital inputvalueAnalog output
I/O characteristics
VoltageCurrentVoltageCurrent
Output range switchingOffset/gain settingOutput short-circuit protectionMaximum conversion speedAnalog output pointsNumber of stations occupiedConnection terminal blockApplicable wire sizeModule mounting screwApplicable DIN railApplicable solderless terminalInternal current consumption (24 VDC)Weight (kg)
Output specifications Description
Analog output
Voltage
Current
-10 to +10V-10 to +10 (User range setting 1)
0 to 5V1 to 5V
0 to 5V (User range setting 2)
0 to 20mA4 to 20mA
0 to 20mA (User range setting 3)
For each channelProvidedProvided
1ms/channel2 channels/module
1 station (RX/RY: 32 points each, RWr/RWw: 4 words each)7-point 2-piece terminal block (transmission, power supply), directly mounted 18-point terminal block (analog output area), M3 screws
0.3 to 0.75 mm2
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN railTH35-7.5Fe, TH35-7.5Al (conforming to JIS-C2812)
RAV1.25 to 3.5 (conforming to JIS-C2805)0.16A
0.2
2.5mV2.5mV
1.25mV1.0mV1.0mV5µA4µA4mA
±0.4%
(±40mV)
±0.4%
(±20mV)
±0.4%
(±80µA)
±0.2%
(±20mV)
±0.2%
(±10mV)
±0.2%
(±40µA)
-4000 to +4000-4000 to +4000
0 to 40000 to 40000 to 40000 to 40000 to 40000 to 4000
Digital value Maximum resolutionAccuracy
Ambient temperature 0 to 55°C Ambient temperature 25±5°C* Accuracy (accuracy relative to the maximum digital output value)
Screw T. block
Screw terminal block type
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
Voltage/current input module
AJ65SBT-64AD
Unit: mm
st.1Occupied
CH4Channel
Analog input
Digital value
I/O characteristics
Input range switching
Offset/gain setting
Maximum conversion speed
Absolute maximum input
Analog input points
Station type
Number of stations occupied
Withstand voltage
Isolation method
External connection
Applicable wire size
Module mounting screw
Applicable DIN rail
Applicable solderless terminal
Internal current consumption (24VDC)
Weight (kg)
Voltage
Current
Analog input range
Voltage
Current
-10 to +10V-10 to +10 (User range setting 1)
0 to 5V1 to 5V
0 to 5V (User range setting 2)
0 to 20mA4 to 20mA
0 to 20mA (User range setting 3)
-4000 to +4000
0 to 4000
0 to 4000
For each channel
Provided
1ms/channel
Voltage: ±15V, Current: ±30mA
4 channels/module
Remote device station
1 station (RX/RY: 32 points each, RWr/RWw: 4 words each)
Between batch of power supply/communication systems and batch of analog inputs: 500 VAC for one minute
Across power supply system terminals and all analog input terminals: Photocoupler isolation,
Across communication system terminals and all analog input terminals: Photocoupler isolation, Between channels: No isolation
7-point 2-piece terminal block (transmission, powe supply), directly mounted 18-point terminal block (analog output area)
0.3 to 0.75mm2
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail
TH35-7.5Fe, TH35-7.5Al (conforming to JIS-C2812)
RAV1.25 to 3.5 (conforming to JIS-C 2805)
0.09A
0.20
2.5mV
1.25mV1.0mV1.0mV5µA4µA4µA
±0.4%
(±16 digit*)
±0.2%
(±8 digit*)
Digital value Maximum resolutionAccuracy
Ambient temperature 0 to 55°C Ambient temperature 25±5°C* Accuracy (accuracy relative to the maximum digital output value)
Output specifications Description
Screw T. block
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
-10 to +10VDC (input resistance 1M )
0 to 20mA DC (input resistance 250 )
-4096 to +4095
16-bit signed binary (-4096 to +4095)16-bit signed binary (0 to +4095)
-10 to +10VDC (external load resistance: 2k to 1M )0 to 20 mA DC (external load resistance: 0 to 600 )
*1 Use a 2-core twisted shield wire.*2 Connect a capacitor of around 0.1 to 0.47 µF (it must be able to
withstand voltages of 25 V or more) to the input terminals of an external device if noise or ripple is generated in the external wiring.
40
NP 40
NC V+ l+ NC
NC
l+
NC
V+
COM
NC
NC
TEST
TEST
24G+24V
(FG)
DG
SLD
DA
DB COM NC NC
NC
NC
V+COM
CH1
V+COM
CH2
GND
*1 *2
GND
Motor drive module, etc.
Motor drive module, etc.
Motor drive module, etc.
Motor drive module, etc.
D/Aconversion
I+COM
CH1
I+COM
CH2
GND
*1 *2
to
to
to
to
GND
Voltage output
Current outputPW RUN L RUN L ERR. CH1 2 OFFSET GAIN
MITSUBISHI AJ65SBT-62DA
DA DG +24V 24GDB SLD (FG)
TESTTEST NC
V+ I+ NC NCCOM NC NC COM NC NC NC
V+ I+ NCNCCH1 CH2
SELECT
SET
UP
DOWN
STATION NO. B RATE40 20 10 8 4 2 1 4 2 1 ON
2-4.5 X 5.1 Mounting hole (M4 mounting screw)
118
109
504
16.5
(4.5)(4.5)
D/Aconversion
2-4.5 X 5.1 Mounting hole (M4 mounting screw)
118
504
16.5
PW RUN L RUN L ERR. CH1 2 OFFSET GAIN
MITSUBISHI AJ65SBT-64AD
DA DG +24V 24GDB SLD (FG)
TESTTEST V+ I+
AGV+ I+CH1 CH2
SELECT
SET
STATION NO. B RATE40 20 10 8 4 2 1 4 2 1 ON
3 4
(FG1)
COMSLDCOMV+ I+
V+ I+COMSLDCOM
CH3 CH4
109(4.5) (4.5) 40
V+I+
COMSLD
V+I+
COMSLD
FG1
CH1+15V
-15V
GND
*4
*1 Shield
*1 Shield*5
*3
CH4
*2
Signal source 0 to ±10V
Signal source 0 to ±20mA
AG
Voltage input0 to ±10V
Voltage input0 to ±20mA
*1 Use a 2-core twisted shield wire.*2 Indicates each input resistance of the AJ65SBT-64AD.*3 Connect a capacitor of around 0.1 to 0.47 µF (it must be a product
that can withstand voltages of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring.
*4 Be sure to ground FG1. AG should be also grounded in the case of frequent noise.The offset and gain values must be set again if the ground wiring (grounded or not) is changed after setting the values.
NP 40
l+ COM SLD COM
V+
V+
COM
l+
SLD
V+
COM
TEST
TEST
24G+24V
(FG)
DG
SLD
DA
DB l+ V+ l+
AG
FG1
500K
500K250
500K
500K250
2k
1M
2k
1M
0
600
0
600
99 100
Analog modulesProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Screw/2-piece terminal block type
Overview
Part names and functions
Features
Screw/2-piece terminal block typeScrew T. block
MITSUBISHISTATION NO.
X10 X1
5
0 1
46
23
5
0 1
46
9237
8
1
4
23
CH. OFFSET GAIN RESET
MELSEC A J65BT-64AD0 1
4
23
B RATE
PW
RUN
L RUN
SD
RD
L ERR.
AJ65BT-64AD
AJ65BT-64DAV/AJ65BT-64DAI
MITSUBISHISTATION NO.
X10 X1
5
0 1
46
23
5
0 1
46
9237
8
1
4
23
CH. OFFSET
GAIN
SET
UP
DOWN
RESET
MELSEC A J65BT-64DAV0 1
4
23
B RATE
PW
RUN
L RUN
SD
RD
L ERR.
AJ65BT-68TDAJ65BT-64RD3/AJ65BT-64RD4
The I/O terminal block is removable.
The 2-piece structure allows easy servicing such as
module replacement without rewiring.
DOWNGAIN
MITSUBISHISTATION NO.
X10 X1
MODE OFFSET UP RESET
MELSEC A 0
B RATE
PWRUN
L RUNSDRD
L ERR.
432
1 0
6 5 432
1 0987
6 5 432
1
0987
6 5 432
1SW MODE0 NORMAL
TEST CH.9 TEST
SET
CD
AB
* When using in the range 0 to 20mA, select D.
Station number setting switch
Transmission rate setting switch
Channel selection switch
OFFSET switch
Analog input rangesetting pin
GAIN switchRESET switch
PWRUN
L RUNSDRDL ERR.
LED name Description
01234
0 to 4 other
Setting value Transmission rate156kbps (factory default)
625kbps2.5Mbps5Mbps10Mbps
Use prohibited(The L ERR. LED turns on, showing
a communication error.)
ABCD
Voltage0 to 10V1 to 5V
-10 to 10V0 to 5V
Current(0 to 20mA)*4 to 20mA
-20 to 20mA0 to 20mAOperation status LEDs
Terminal blockTerminal block for connection to the module power supply, transmission and I/O signals lines.
Set the analog input range. (side)
ON: Power is turn on.NormalmodeON: Normal communicationON: Data being sentON: Data being receivedON: Communication data error
ON: Normal operation
Station number setting switch
Transmission rate setting switch
Channel selection switch
OFFSET switch
UP/DOWN switchRESET switch
PWRUN
L RUNSDRDL ERR.
LED name Description
01234
Setting value Transmission rate156kbps (factory default)
625kbps2.5Mbps5.0Mbps10Mbps
Operation status LEDs
Terminal blockTerminal block for connection to the module power supply, transmission and I/O signal lines.
Terminal blockTerminal block for connection to the module power supply, transmission and I/O signal lines.
Station number setting switch
Transmission rate setting switch
01234
0 to 4 other
Setting value Transmission rate156kbps (factory default)
625kbps2.5Mbps5Mbps
10MbpsUse prohibited
(The L ERR. LED turns on, showing a communication error.)
UP/DOWN switchRESET switch
ON: Power is turn on.NormalmodeON: When communication is normal.ON: Data being sentON: Data being receivedON: When the baud rate or station
number setting is invalid
ON: Normal operation
PWRUN
L RUNSDRDL ERR.
LED name Description
Setting Description
Setting Description
Operation status LEDs
ON: Power is turn on.NormalmodeON: When communication is normal.ON: Data being sentON: Data being receivedON: Communication data error
(CRC error)
ON: Normal operation
Connecting Pt100
Circuitboard
Connecting JPt100Circuitboard
Offset/gain setting switch
Mode switch
OFFSETGAINSET
Compensation mode for the offset valueCompensation mode for the gain valueStores a temperature value, which is detected when this switch is changed from OFFSET/GAIN to SET, in the internal memory as an offset/gain value.
Pt100 RTDResistance temperature detector for measuring terminal block temperature (attached to the module)
Pins for specifying the platinum RTD type
0
1 to 8
9
NORMAL
TEST CH.
TEST
Terminates the test mode in normal operation. (Factory default)Used to select a channel in the test mode to compensate for errors of the channel.To compensate for errors, select this. After 2 seconds, the system enters the test mode.
J65BT-
101 102
Analog modulesAnalog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Voltage/current input module
AJ65BT-64AD
Unit: mm
st.s2Occupied
CH4Channel Screw T. block
Screw T. block
Detachable screw Terminal Block Type
Analog input
Digital value
Input/output characteristics
Input range switching
Offset/gain setting
Maximum conversion speed
Absolute maximum input
Analog input points
Station type
No. of stations occupied
Withstand voltage
Isolation method
External connection method
Applicable wire size
Module mounting screws
Applicable DIN rail
Applicable solderless terminal
Internal current consumption (24VDC)
Weight (kg)
External dimensions
Voltage
Current
Analog input range
Voltage/current
Voltage
Current
-10 to +10V0 to +100 to 5V1 to 5V
-20 to 20mA
0 to 20mA
4 to 20mA
0 to +4000or
-2000 to +2000
0 to +4000or
-2000 to +2000
All channels in batch
Provided
1 ms/channel
Voltage: ±15V, Current: ±30mA
4 channels/module
Remote device station
2 stations (RX/RY: 32 points each, RWr/RWw: 8 words each)
Between batch of power supply/communication systems and batch of analog inputs: 500 VAC for one minute
Between power supply system and batch of analog inputs: Photocoupler isolation/Between communication system and batch of analog inputs: Photocoupler isolation/Between channels: No isolation
27-point terminal block (M3.5)
0.75 to 2.00mm2
M4 x 0.7mm x 16mm or more, possible to mount on a DIN rail
TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
RAV1.25 to 3.5, RAV2 to 3.5
0.12A
0.35kg
151.9(W) x 65(H) x 63(D)mm
5mV2.5mV
1.25mV1mV20µA10µA5µA4µA
Digital value Maximum resolutionAccuracy
Ambient temperature 0 to 55°C
±1%
(±40 digit*)
*: 1digit refers to one digital unit.
* Accuracy (accuracy relative to the maximum digital output value)
Output specifications Description
Current output module
AJ65BT-64DAI
Unit: mm
st.s2Occupied
CH4Channel Screw T. block
Voltage output module
AJ65BT-64DAV st.s2Occupied
CH4Channel Screw T. block
Digital value
Analog output
I/O characteristics
Output range switching
Offset/gain setting
Output short-circuit protection
Maximum conversion speed
Analog output points
No. of stations occupied
Terminal block
Applicable wire size
Module mounting screws
Applicable DIN rail
Applicable solderless terminal
Internal current consumption (24VDC)
Weight (kg)
Model name
Voltage
Current
Voltage
Current
+2000+1000
0-1000-2000
--
+10V+5V±0-5V
-10V
--
5mV
--
±1%(±100mV)
--
0.18 A 0.27A
None
Provided
Provided
1 ms/channel
4 channels/module
2 stations (RX/RY: 32 points each, RWr/RWw: 8 words each)
17-point terminal block, M3.5 screws
0.75 to 2.00mm2
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail
TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
RAV1.25 to 3.5, RAV2 to 3.5
0.4
Digital value Analog output Max. resolution Accuracy (overall)
AJ65BT-64DAV
* Accuracy (accuracy relative to the maximum digital output value)
AJ65BT-64DAI
40002000
0
+20mA+12mA+4mA
4µA±1%
(±200µA)
Digital value
--
Analog output
--
Max. resolution
--
Accuracy (overall)
--
Description
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
-10 to +10VDC (input resistance 1M )
-20 to 20 mADC (input resistance 250 )
-2000 to +2000 or 0 to +4000
16-bit signed binary (-2048 to +2047)
---10 to +10VDC (external load resistance: 2k to 1M )
--
-
16-bit signed binary (0 to 4095)-
4 to 20mA DC (external load resistance: 0 to 600 )
l+ SLD l+ SLD
COM
COM
V+
V+
l+SLDI+
V+
TEST
24G
TEST
+24V
(FG)
DG
SLD
DA
DB V+ COM AG
FG1
63
PW RUN
L RUN SD RD
LERR.
0
546
1932
78
0
546
132
0
4
BRATEX10
CH. OFFSETGAIN.
MELSEC A J65BT-64AD
RESET
151.9
X1STATION NO.
132
4
132
142.9
56 65
CH2V+
CH3V+
COMTESTTEST
HLD/CLR
HLD/CLR
CH1V+
24G+24V
(FG)
DG
SLD
DA
DB COM COM
CH4V+
COM
CH2I+
CH3I+
COMTESTTEST
HLD/CLR
HLD/CLR
CH1I+
24G+24V
(FG)
DG
SLD
DA
DB COM COM
CH4I+
COM
63
PW RUN
L RUN SD RD
LERR.
0
546
1932
78
0
546
132
0
4
BRATEX10
CH. OFFSETGAIN.
MELSEC A J65BT-64DAV
RESET
151.9
X1STATION NO.
132
4
132
142.9
56 65
V+COM
CH1
V+COM
CH4
GND
*1 *2
GND
Motor drive module, etc.
Motor drive module, etc.
I+COM
CH1
I+COM
CH4
GND
*1 *2
to
to
to
to
GND
Motor drive module, etc.
Motor drive module, etc.
*1 Use a 2-core twisted shield wire.*2 Connect a capacitor of around 0.1 to 0.47 µF (it must be a product that
can withstand voltages of 25 V or more) to the input terminals of an external device if noise or ripple is generated in the external wiring.
V+I+
COMSLD
V+I+
COMSLD
FG1
CH1+15V
-15V
GND
*4
*1 Shield
*1 Shield*5
*3
CH4
*2
Signal source 0 to ±10V
Signal source 0 to ±20mA
AG
Voltage inputSignal source0 to ±10V
Current inputSignal source0 to ±20mA
*1 Use a 2-core twisted shield wire.*2 Indicates each input resistance of the AJ65BT-64AD.*3 In the case of current input, be sure to connect (V+) and (I+)
terminals.*4 Connect a capacitor of around 0.1 to 0.47 µF (it must be able to
withstand voltages of 25 V or more) between the V and COM terminals if noise or ripple is generated in the external wiring.
*5 Be sure to ground FG1. AG should be also grounded in the case of frequent noise.The offset and gain values must be set again if the ground wiring (grounded or not) is changed after setting the values.
AJ65BT-64DAV
AJ65BT-64DAI
AJ65BT-64DAV
AJ65BT-64DAICOM
500K
500K250
500K
500K250
2- 4.5 mounting hole
2k
1M
2k
1M
0
600
0
600
2- 4.5 mounting hole
103 104
Analog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Thermocouple temperature input module
AJ65BT-68TD
Unit: mm
*1 Use shielded compensating lead wires.*2 Be sure to ground it.
st.s4Occupied
CH8Channel Screw T. block
Screw T. block
Detachable screw terminal block type
Connectable thermocouples
Temperature input range
Temperature detection
value
Scaling value
Overall accuracy
Cold-junction compensation accuracy
Resolution
Conversion speed
(sampling time: ms/ch) *2
Temp. sensor input channel
Station type
No. of stations occupied
Isolation method
Applicable solderless terminal
Terminal block
Allowable momentary power failure period
Applicable wire size
Module mounting
screws
Applicable DIN rail
External power supply
Internal current
consumption (24 VDC)
Weight (kg)
B, R, S, K, E, J, T
-200 to 1700°C
16-bit signed binary
(-2000 to 17000: Value to 1 decimal place x 10)
16-bit signed binary (0 to 2000)
*1
±1.0°C
B, R, S: 0.3°C, K, E, J, T: 0.1°C
45 ms/channel
8 + 1 (Pt100 connected) channels
Remote device station
4 stations
(RX/RY: 128 points each, RWr/RWw: 16 words each)
Between thermocouple input and CC-Link transmission
system and between channels: Transformer isolation
RAV1.25 to 3, RAV2 to 3.5 (compliant to JIS C 2805)
27-point terminal block (M3.5 x 7 screws)
1ms
0.75 to 2.00 mm2
M4 x 0.7 mm x 16 mm or more,
possible to mount on a DIN rail
TH35-7.5Fe, TH35-7.5Al,
TH35-15Fe (compliant to JIS C 2812)
24 VDC (18 to 30 VDC)
0.081A
0.4
Input specifications Description
The calculation method of overall accuracy is as shown below:(Overall accuracy) = (Conversion accuracy) + (Temperature characteristic) x(Operating ambient temperature change) + (Cold-junction compensation accuracy)Here, the operating ambient temperature change denotes a value varied from the operating ambient temperature range of 25±5°C.Example: The overall accuracy with operating thermocouple of K, measured temperature of 150°C, and operating ambient temperature of 35°C is: (±0.5°C) + (±0.06°C) x (5°C) + (±1°C) = ±1.8°C
Platinum RTDPt 100 temperature input module
AJ65BT-64RD4Unit: mm
*1: Depending on the operating environment, it may be better to be connected.
st.s4Occupied
CH4Channel Screw T. block
Platinum RTD Pt 100 temperature input module
AJ65BT-64RD3 st.s4Occupied
CH4Channel Screw T. block
Measurement methodConnectable platinum RTDTemperature input rangeTemperature detection value
Overall accuracy
Resolution (°C)Conversion speed (sampling time: ms/ch) *2Temp. sensor input channelStation typeNo. of stations occupied
Isolation method
Applicable solderless terminalTerminal blockAllowable momentary power failure periodApplicable wire sizeModule mounting screwsApplicable DIN rail
External power supplyInternal current consumption (24VDC)Weight (kg)
0.025°C
40ms/channel
4 channels/moduleRemote device station
4 stations (RX/RY: 128 points each, RWr/RWw: 16 words each)
Between platinum RTD inputs and CC-Link transmission system: Photocoupler isolation,
Between channels: Not isolatedRAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805)
27-point terminal block (M3.5 x 7 screws)
1ms
0.75 to 2.00 mm2
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN rail
TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
24 VDC (18 to 30 VDC)
0.17A
0.38
Pt100, JPt100-180 to 600°C
16-bit signed binary (-1800 to 6000: Value to 1 decimal place x 10)
32-bit signed binary (-180000 to 600000: Value to 3 decimal places x 1000
Input specificationsDescription
AJ65BT-64RD33-wire type
AJ65BT-64RD44-wire type
*1
±0.1%(relative to the maximum value)
±0.25% (relative to the maximum value)
Ambient temperature (25±5°C)
Ambient temperature (20°C or less, 30°C or more)
MemoMemoMemoExternal dimensions & terminal layoutExternal device connection diagram
Detailed specifications
External dimensions & terminal layoutExternal device connection diagram
Detailed specifications
CH1-
CH2-
CH3-
CH4-
CH1+
CH2+
CH3+
CH4+
CH5-
CH6-
CH7-
CH8-
CH5+
CH6+
CH7+
CH8+
RTD RTD24G+24V
(FG)
DG
SLD
DA
DB
RTD
CH1+-
CH8
Pt100
*1*2
+-
142.9151.9
56.0
65.0
63.0
DOWNGAIN
MITSUBISHISTATION NO.
X10 X1
MODE OFFSET UP RESET
MELSEC AJ65BT-68TD 0
B RATE
PWRUN
L RUNSDRD
L ERR.
432
1 0
6 5 432
1 0987
6 5 432
1
0987
6 5 432
1 SET
9
MODENORMALTEST CH.
TEST
0SW
NC B1 SLD NC
A1 b1 SLD A2
B2 NC B3 SLD
b2 A3 b3 SLD A4 b424G+24V
(FG)
DG
SLD
DA
DB
142.9151.9
56.0
65.0
63.0
The highest accuracy can be obtained for AJ65BT-64RD3 by using 3-wire type platinum RTD.Example of connecting a 3-wire type platinum RTD.
The highest accuracy can be obtained for AJ65BT-64RD4 by using 4-wire type platinum RTD.Example of connecting a 4-wire type platinum RTD.
SLDb1B1A1
GND
Shield
*1
a1CH1 Constant
V.circuit
SLDb4B4A4a4
CH4
A1B1b1
SLD
Inte
rnal
circ
uit
Inte
rnal
circ
uit
Inte
rnal
circ
uit
Inte
rnal
ci
rcui
t
GND
GND Shield
*1
CH1
A1B1b1
SLD
CH4 DOWNGAIN
MITSUBISHISTATION NO.
X10 X1
MODE OFFSET UP RESET
MELSEC AJ65BT-64RD3 0
B RATE
PWRUN
L RUNSDRD
L ERR.
432
1 0
6 5 432
1 0987
6 5 432
1
09
432
1 SETSW MODE0 NORMAL
TEST CH.9 TEST
B4NC
a1 B1 SLD a2
A1 b1 SLD A2
B2 a3 B3 SLD
b2 A3 b3 SLD A4 b424G+24V
(FG)
DG
SLD
DA
DB B4a4
Am
plifi
er
inpu
tA
mpl
ifier
in
put
Filt
erF
ilter
Am
plifi
er
inpu
t
Tran
sfor
mer
Tran
sfor
mer
AJ65BT-64RD4
AJ65BT-64RD3AJ65BT-64RD4
AJ65BT-64RD3
2- 4.5 mounting hole
2- 4.5 mounting hole
105 106
Analog modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Features
High-speed counter module
AJ65BT-D62AJ65BT-D62DAJ65BT-D62D-S1
Counting speed switch settingNumber of channelsCount input signalCounter
Coincidence outputExternal input
External outputStation typeNo. of stations occupiedPower supply voltageCurrent consumption (at 24VDC)Terminal blockApplicable wire sizeApplicable solderless terminalAllowable momentary power failure periodModule mounting screwsApplicable DIN railWeight (kg)
Model name
1-phase input2-phase input
AJ65BT-D62
24-bit binarySet value < Count value, Set value = Count value, Set value > Count value
2A/1 common0.1 ms or less
Remote device station4 stations
18 to 28.8 VDC100mA
27-point terminal block (M3.5 x 7 screws)0.75 to 2.00 mm2
RAV1.25 to 3, RAV2 to 3.5 (compliant to JIS C 2805)
1ms
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN railTH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
5/12/24VDC2 to 5mA
200kpps
200kpps
10kpps
7kpps
400kpps
300kpps
10kpps
7kpps
400kpps
300kpps
10kpps
7kpps
EIA standard, RS-422-A differential type line driver level [Equivalent to Am26L31 (Japan Texas Instruments, Inc)]
HIGH side LOW side
5/12/24VDC2 to 5mA
DC5/12/24VDC 2 to 5mA
70mA
0.41kg
120mA
0.42kg
EIA standard, RS-422-A differential type line driver level [Equivalent to Am26L31 (Japan Texas Instruments, Inc)]
5/12/24VDC 2 to 5mA
2 channels1-phase input, 2-phase input
24-bit binary 0 to 16777215
Up/down preset counter and ring counter functions
AJ65BT-D62D AJ65BT-D62D-S1HIGH side LOW side HIGH side LOW side
5µs 100µs 142µs
2.5µs 50µs
50µs
71µs
71µs
2.5µs
(1- and 2-phase input)*1 *1 *2 *2 *2 *2(1-phase input) (2-phase input)
100µs 142µs
50µs
50µs
71µs
71µs
(1-phase input) (2-phase input)
100µs
50µs
50µs
142µs
71µs
71µs
(1-phase input) (2-phase input)
2.5µs 3.3µs
1.25µs
1.25µs
1.65µs
1.65µs
(1-phase input) (2-phase input)
2.5µs 3.3µs
1.25µs
1.25µs
1.65µs
1.65µs
(1-phase input) (2-phase input)
*1 The rise or fall time of the input signal should be 2 µs or less and have a duty ratio of 50%.*2 The rise or fall time of the input signal should be 0.1 µs or less and have a duty ratio of 50%.
Unit: mm
User's manual IB-66823C (13JL45)
OFF ON : 0.5 ms or less, ON OFF : 3 ms or less
PhaseSignal level( A, B)Countingspeed (Max.)Counting rangeTypeMinimum count pulse width
Comparison rangeComparison resultPreset
Function startResponse timeCoincidence outputResponse time
Wide counting range, from 0 to 16777215 (24-bit binary).External input: 5/12/24VDC (2 to 5mA)Multiplication of count values is possible.Counting speed switching enables error-free counting even in the case of slow rise or fall.The following 4 counter functions are available.
Latch counter functionSampling counter functionPeriodic pulse counter functionCount disable function
Part names and functions
External connection diagram (Example of connection with a pulse generator) External dimensions
Related manual
Performance specifications
RESET
B RATE STATION NO.X10 X1
5
0
6
92
78
1
345
0
6
21
34
02
1
34
RINGCH. 1 2
PLSCH. 1 2
LOW
HIGH
DECPREF ST.
EQU1EQU2
DECPREF ST.EQU1EQU2
CH.1 CH.2
ON
PWRUN
L RUNSDRD
L ERR.
MITSUBISHI MELSEC A J65BT-D62
AJ65BT-D62 AJ65BT-D62D AJ65BT-D62D-S1
F ST.PRE
24V
12V 5V
CH.1
(When the jumper is connected to 12 V)
F ST.
24V
12V 5V
CH.1
(When the jumper is connected to 24 V)
CH.1
PREF ST.
24V
12V 5V 24V
12V 5V
Circuit board
Jumper(When the jumper is connected to 5 V)
LED indication
Ring counter setting switchThis is used to set whether to enable or disable the ring-counter function.
Mode switch
Terminal block
Pulse input setting pin (same for CH.2)
PWRUNL RUNSDRDL ERR.
LED name Description
LED name Description
Station number setting switches
Reset switch
LED indicationThe station number of the high-speed counter module is set within the range from 1 to 61.Set the 10s place using the “X10” switch.Set the 1s place using the “X1” switch.
Transmission rate setting switchThe transmission rate of the high-speed counter module is set (for data link).
01234
Other than0 to 4
Setting number Transmission speed156 kbps (factory default)
625kbps2.5Mbps5Mbps
10MbpsNot used (Setting a value other than 0 to 4 turns
on the L ERR. LED, generating a communication error.)
ON: Power supply onON: Normal operationON: Normal communicationON: Data being sentON: Data being receivedON: Communication error
142.9151.9
56 65
RESET
B RATE STATION NO.X10 X1
5
0
6
92
78
1
345
0
6
21
34
02
1
34
RINGCH. 1 2
PLSCH. 1 2
LOW
HIGH
DECPREF ST.
EQU1EQU2
DECPREF ST.EQU1EQU2
CH.1 CH.2
ON
PWRUN
L RUNSDRD
L ERR.
MITSUBISHI MELSEC AJ65BT-D62
9.5
63
PRE PRE
FST FST
CH.1 CH.2
24V
12V 5V 24V
12V 5V 24V
12V 5V 24V
12V 5V
A
A
Twisted shielded cable
Twisted shielded cable
Pulse generator
External power supply
VCCGND GND
VCC
B
B
E
EAm26LS32
A
A
B
B
E+24V
OUTTwisted shielded cable
Shield
Twisted shielded cable
Shield E+24V
OUT
Pulse generator
External power supply
DC24V0V 0V
+24V
EGND
OUT
EGND
OUT
0VDC+5V
Twisted shielded cable
Twisted shielded cable
External power supply
DC24V0V
Pulse input voltage setting p in*
Pulse input voltage setting p in*
Pulse input voltage setting p in*
Pulse input voltage setting p in*
Twisted shielded cable
Pulse generator
External power supply
VCCGND
Twisted shielded cable
E
Am26LS32 E
GNDVCC
A
A
B
B
A
A
B
B14050
Twisted shielded cable
Am26LS32 E
PRESET Z
Z14050 PRESET
Example of connection with an open-collector output type pulse generator (24VDC)
Example of connection with a line driver pulse generator (equivalent to Am26L31)
Example of connection with a voltage-output type pulse generator (5VDC)
Remark:* Set the pulse input voltage setting pin to the position.Remark:* Set the pulse input voltage setting pin to the position.
COM24G+24V
(FG)
DG
SLD
DA
DB RESET F.START
RESET
COM
F.START
EQU1
EQU2
EQU1
EQU1 COM
12/24V
COM24G+24V
(FG)
DG
SLD
DA
DB RESET F.START
RESET
COM
F.START
EQU1
EQU2
EQU1
EQU1 COM
12/24V
RESET F.START24G+24V
(FG)
DG
SLD
DA
DB RESET F.START RESET
RESET
F.START
F.START
EQU1
EQU1 COM
12/24V
AJ65BT-D62 AJ65BT-D62
AJ65BT-D62D AJ65BT-D62D-S1
A B
B
B
BA
A
A
AA
BB
AA
BB
AA
AA
BB
BB
AA
BB
BB
AA
AA
AA
BB
BB
2- 4.5 Mounting hole
A
B
DECPRE
F ST.
EQU1
EQU2
Turns on when voltage is applied to the phase A pulse input terminal.Turns on when voltage is applied to the phase B pulse input terminal.Turns on when the counter value is decremented.Turns on and remains on when voltage is applied to the RESET terminal.Turns off when the external preset detection reset command signal turns on.Turns on when voltage is applied to the F.START terminal.Turns on when coincidence output setting No.1 = counter valueTurns on when coincidence output setting No.2 = counter value (Not available for AJ65BT-D62D-S1)
5101/3W
4.7K 1/3W4.7K 1/3W
5101/3W
4.7K 1/3W4.7K 1/3W
5101/3W
4.7K 1/3W4.7K 1/3W
5101/3W
4.7K 1/3W4.7K 1/3W
107 108
High-speed counter modulesHigh-speed counter modulesProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
AJ65BT-D62
AJ65BT-D62D
AJ65BT-D62D-S1
Features
Positioning module
AJ65BT-D75P2-S3
Item SpecificationNo. of control axesInterpolation functionControl method
Control unit Positioning data Peripheral device/software package
Teaching unit Backup
Positioning method
Positioning range
Speed command
Acc/DecprocessingAcc/Dec time
Sudden stop deceleration timeStarting time
2 axes2-axis linear interpolation, 2-axis circular interpolation *1PTP (Point to Point) control, locus control (both linear and circular interpolation), speed control, speed/position switching controlmm, inch, degree, pulseUp to 600 data (positioning data No.: 1 to 600) per axisWindows version 75PGX Configurator-APA7HGP /SW1RX-AD75P or laterPC-9800 series /SW1NX-AD75P or later *2DOS/V PC IBM PC/AT compatible PC/SW1IVD-AD75P or later *3AD75TU (software version D or later)Parameters and positioning data are stored in the flash memory (battery-less).PTP control: Incremental/absolute systemSpeed/position switching control: Incremental/absolute system *4Locus control: Incremental/absolute systemAbsolute system. -214748364.8 to 214748364.7 (µm)/ -13421772.8 to 13421772.7 (µm) *5
. -21474.83648 to 21474.83647 (inch)/ -1342.17728 to 1342.17727 (inch)
. 0 to 359.99999 (degree)/0 to 359.99999 (degree)
. -2147483648 to 2147483647 (pulse)/ -134217728 to 134217727 (pulse)
Incremental system. -214748364.8 to 214748364.7 (µm)/ -13421772.8 to 13421772.7 (µm)
. -21474.83648 to 21474.83647 (inch)/ -1342.17728 to 1342.17727 (inch)
. -21474.83648 to 21474.83647 (degree)/ -1342.17728 to 1342.17727 (degree)
. -2147483648 to 2147483647 (pulse)/ -134217728 to 134217727 (pulse)
Speed/position switching control (incremental system). 0 to 214748364.7 (µm)/0 to 13421772.7 (µm)
. 0 to 21474.83647 (inch)/0 to 1342.17727 (inch)
. 0 to 21474.83647 (degree)/0 to 1342.17727 (degree)
. 0 to 2147483647 (pulse)/0 to 134217727 (pulse)
Speed/position switching control (absolute system). 0 to 359.99999 (degree)/0 to 359.99999 (degree)
0.01 to 6000000.00 (mm/min)/0.01 to 375000.00 (mm/min) *50.001 to 600000.000 (inch/min)/0.001 to 37500.000 (inch/min)0.001 to 600000.000 (degree/min)/0.001 to 37500.000 (degree/min)1 to 1000000 (pulse/s)/1 to 62500 (pulse/s)Automatic trapezoidal acceleration/deceleration andS-curve acceleration/deceleration *6Can be switched between “1 to 65535” and “1 to 8388608” (ms).4 patterns can be set for each of the acc. and dec. times.Can be switched between “1 to 65535” and “1 to 8388908” (ms).(The ranges are same as those of the Acc/Dec time.)20 ms or less (excluding link scan time)
Item Specification
Connector
Applicable wire size
Maximum output pulseMaximum connection distance between servosStation type No. of stations occupiedExternal power supplyApplicable wire size Module mounting screwsApplicable DIN railApplicable solderless terminal 24 VDC internal current consumptionExternal dimensions Weight (kg)
10136-3000VE (soldering-type, accessory)10136-6000EL (pressure connection type, sold separately)10136-3000VE: AWG#24 to #30 (approx. 0.05 to 0.2SQ)10136-6000EL: AWG#28 (approx. 0.08SQ)When connected to differential driver: 400kbpsWhen connected to open collector: 200kbpsWhen connected to differential driver: 10mWhen connected to open collector: 2mIntelligent device station4 stations (RX/RY: 128 points each, RWr/RWw: 16 words each)24VDC (20.4 to 26.4VDC)0.75 to 2.00 mm2
M4 x 0.7 mm x 16 mm or more, possible to mount on a DIN railTH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
RAV1.25 to 3.5, RAV2 to 3.5
0.30A
170 (W) x 63.5 (H) x 80 (D) mm0.50
The positioning modules can be utilized in distributed control.
An absolute position detection system can be easily constructed by using the AC servo MELSERVO-H/J2/J2S Series.
A built-in differential driver has realized the following:High-speed pulse output (400kpps)Longer connection distance to a driver unit (up to 10m)
Various positioning control functionsA large number of positioning data can be set up to 600 per axis.Seven kinds of zero return functions are available.Automatic trapezoidal acceleration/deceleration or S-curve acceleration/deceleration functions are selectable.
Related manualUser's Manual IB-66824 (13JL46)
Performance specifications
Positioning
*1 The circular interpolation function is not available when a stepping motor is used.*2 PC-9800 Series is a registered trademark of NEC*3 DOS/V is a registered trademark of IBM Japan, Ltd.*4 In the absolute system, the control unit of the speed/position switching control is
"degree" only.*5 Indicates a setting range of "standard mode/stepping motor mode."*6 The automatic S-curve acceleration/deceleration is not available when a stepping
motor is used.
Part names and functions
External dimensions
63.5
9.5
161
170
8071
The axis corresponding to “17-segment LED” message is indicated.
Axis LEDs display
Depending on the mode, an operating status message is displayed.
17-segment LED display
RS-422 connector for peripheralsThis connector is used for connection with peripheral devices.
Data link terminal block Connect the power supply and the twisted cable for the data link. (2-piece terminal block)
These connectors are used to connect to drive units, mechanical system inputs and manual pulse generators.
Drive unit connectors (AX1 and AX2)
CC-Link status LEDsThese LEDs display power-supply status and data-communication status.
Transmission rate setting switchThe data communication is set.
Station number setting switches The station number of the D75P2 is set.
Press this switch to initialize the input signal, remote register, and operation processing.
Reset switch
The information displayed in the "[1] Axis LED" and the "17-segment LED display" is switched every time this switch is pressed.
LED display mode selector switch
01234
156kbps625kbps2.5Mbps5Mbps
10Mbps
Setting number Transmission ratePWRUNL RUNSDRDL ERR.
LED name DescriptionON: Power supply onON: Normal operationON: Normal communicationON: Data being setON: Data being receivedON: Communication error
B RATE
Unit: mm
2- 4.5 Mounting hole
109 110
Positioning modulePositioning module Product information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
*1*2
*3*4*5*6
External connection diagram External connection diagram
"AD75C20SNJ2 type cable (for differential driver)" can be used for the connection between D75P2 and MR-J2/J2S-MA.
The same connector pin numbers of D75P2 are used for axes 1 and 2.The upper limit (FLS) and lower limit (RLS) of D75P2 are used in the retry function at the time of zero point return. Set them inside the limit switches for the servo.Limit switch for servo (for stopping)Indicates the distance between the controller and amplifier. It is 2m or less when using the open collector.For the D75P2, select “Negative logic” in “Logic selection for pulse output to the drive unit” of Detailed parameters 1.The in-position signal line is not necessarily to be wired. (The signal is output only to the in-position flag (RX (n+1)4, rx(n+4)4), not being used in the internal processing of the D75P2.)
The figure below does not have a connection for recovering absolute position. See the next page for the connection for recovery of absolute position.
Configure a sequence which will cut off the MC in case of an alarm or emergency stop.
Power supply3-phase 200 VAC
NF MCTE1
CN1A
*
D75P2
DC24V
Near point dogUpper limitLower limitStopSpeed/position switchingStart
External emergency stopServo onResetProportional controlTorque limitForward stroke endReverse stroke end
5VAB
0VManual pulse generator MR-HDP01
RA1
RA2
RA3
FailureZero speed detection
Limiting torque
Within 2 m
Analog torque limit+10V/maximum current
*
*6
*2*2
*3*3
+5V
5G
PULSE F+PULSE F-PULSE R+PULSE R-CLEARCLEAR COMREADYCOMINPS
PGO (5V)PGO COMCOMCOM
DOGFLSRLSSTOPCHGSTRTPULSER A+PULSER A-PULSER B+PULSER B-
OPCPPPGNPNGCRSGRDCOMINP
LZLZR
LGSDCN1BENGSONRESPCTLLSPLSNSGSGVDOCOMALMZSPTLC
P15RTLALGSD
CN3TxDRxDLGLGLGLG
MO1LGMO2LGSD
PULSE F
PULSE COM
PULSE R
PULSE COM
PP
SG
NP
1
19
2
20
3
10
2
D75P2 CN1A
RDSDGNDGNDRSCSDRER
Commercially available PC
Monitor output
10k
A
A
10k
Within 2m
Measurements may oscillate up to 1mA.
* Use the following wiring when connecting with an open collector.
1221
115
15
43
1413
Plate
Plate
Plate
113
1328
10199
18
515
1
155
1489
161710203
1318196
11121
3214
225
237
268
24253536
1112131415169
271028
Within 10 m (within 2 m) *4
L1L2L3
L11L21C TE2DP
UVW
UVWE
SM
EMG
DC24V
B1
B2 Electromagnetic brake
Det
ecto
r
The servo on signal is switched off in case of an alarm signal, shutting down the motor.
CN2
HC-MF, HA-FF Series motor
PEPE
READY
COM 26
PGO (5V) 24
PGO COM 25
CLEAR 5
CLEAR COM 23
PULSE F+ 3
PULSE F- 21
PULSE R+ 4
PULSE R- 22
INPS
D01
8
ABSR
17
SON
31
ABSM
29
ZSP
30
TLC
18
34
PULSE A+ 9
PULSE A- 27
PULSE B+ 10
PULSE B-
DOG
28
FLS
11
RLS
12
STOP
13
CHG
14
STRT
15
COM
16
COM
35
36
COM
COM
DC24V
Plate
33
32
SD
7 RD19
COM9
INP18
LZ5
LZR15
CR8
SG10
PP3
PG13
NP36
NG3
SD
ENG15
ALM18
VDD3
COM13
RES14
LSP16
LSN17
SG10
SG20
P15R
PULSE F
PULSE COM
PULSE R
PULSE COM
D75P2 CN1A
1
19
2
20
11
TLA12
LG1
SON5
PC8
TL9
D014
ZSP19
TLC6
RA2
RA3
RA1
5V
0V
+5V
5G
AB
Manual pulse generator (MR-HDP01)
D75P2
(CN1B)
(CN1A)
Plate
*
PP
SG
NP
3
10
2
* Use the following wiring when connecting with an open collector.
Example of connection between D75P2 and MR-J2/J2S-MA (Differential Driver (Open collector), Negative Logic *5) Example of connection for performing absolute position recovery
MR-J2/J2S- A
Remark
MR-J2/J2S- A
111 112
Positioning module Product informationPositioning module
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Features
Peripheral device connection module
AJ65BT-G4-S3
Peripheral device connector
Station type
No. of stations occupied
Allowable momentary power failure period
Applicable solderless terminal
Module mounting screws
Applicable DIN rail
24 VDC internal current consumption
External power supply (for driving the module)
Weight (kg)
External dimensions
Model name AJ65BT-G4-S3
D-sub 25 pin 1 channel
Intelligent device station
1 station (RX/RY: 32 points each, RWr/RWw: 4 words each)
1ms
RAV1.25 to 3, RAV2 to 3.5 (compliant to JIS C 2805)
M4 x 0.7 mm x 16 mm screws or larger
TH35-7.5Fe, TH35-7.5Al, TH35-15Fe (compliant to JIS C 2812)
Possible to mount on a DIN rail
0.19A
DC24V (15.6 to 28.8V)
0.36
80 (W) x 170 (H) x 63.5 (D) mm
User's Manual SH-080105 (13JR17)
Peripheral devices having MELSEC PLC programming software are connectable.
Compatible MELSEC PLC programming software RemarkConnectable personal computer
GX Developer (SWMD5C-GPPW)
GX Configurator-CC (SWMD5C-J61P)
GX Configurator-AD Ver.2.00A or later (SWMD5C-QADU)
GX Configurator-DA Ver.2.00A or later (SWMD5C-QDAU)
GX Configurator-SC Ver.2.06G or later (SWMD5C-QSCU-J)
SWMIVD-GPPA, SWMIVD-GPPQ
SWMNX-GPPA, SWMNX-GPPQ
GX Explorer (SWMD5C-EXP-J)
GX RemoteService-I (SWMD5C-RAS-J)
MX Component (SWMD5C-ACT)
Windows compatible
IBM PC/AT compatible PC
PC-9800
QCPU is supported
by GX Developers,
SW6D5C-GPPW
or later.
Remote control is available via CC-Link.Online operations, such as writing data to PLC, reading data from PLC, monitoring and testing, can be performed from peripheral devices to QCPUs, QnACPUs or ACPUs that are remotely installed onto a common CC-Link network.
Related manual
Performance specifications
Part names and functions
External dimensions
Peripheral device connections
Unit: mm
63.5
9.5
Rated plate
161
170
4.5
71 80
4.5
B RATE STATION NO.X10 X1
SW1 82 3 4 5 6 7
ONRESET
PWRUN
L RUNSDRD
L ERR.
MITSUBISHI AJ65BT-G4-S3
RS-422
5
0
6
92
78
1
345
0
6
21
34
02
1
34
SW1 MODE
QnAA
non-usedQ
SW6OFFOFFONON
OFF
OFFON
ON
B RATE STATION NO.X10 X1
SW1 82 3 4 5 6 7
ONRESET
PWRUN
L RUNSDRD
L ERR.
MITSUBISHI AJ65BT-G4-S3
RS-422
5
0
6
92
78
1
345
0
6
21
34
02
1
34
SW1 MODE
QnAA
non-usedQ
SW6OFFOFFONON
OFF
OFFON
ON
Reset switchHardware reset
RS-422 interfaceInterface for connecting peripheral devices
Data link terminal block Connect the power supply and the twisted cable for the data link. (2-piece terminal block)
LED indication01234
Other
Settingvalue
156kbps625kbps2.5Mbps5Mbps
10MbpsNot used (Setting a value other than 0 to 4 turns
on the L ERR. LED, generating a communication error.)
Transmission rate
Station number setting switchesStation number of G4-S3 is set in the range from 1 to 63 or 64.
Operation setting DIP switchThis is used for setting the operation specification of G4-S3.
Switchnumber
1.6
2.3
4.578
Setting item
Operation mode
Peripheral device
transmission speed (bps)
Not usedNot used
Test mode
Status of setting switch
Fixed at OFF-
Transmission rate setting switch
ON
SW1OFFONOFFON
SW6OFFOFFONON
Operation modeA mode
QnA modeQ mode
Setting not allowed
OFF
Test mode Online mode
SW2OFFONOFFON
SW3OFFOFFONON
Transmission speed9600bps19200bps38400bps
Setting not allowed
(factory default)PWRUNL RUNSDRDL ERR.
LED name DescriptionON: Power supply onON: Normal operationON: Normal communicationON: Data being sentON: Data being receivedON: Communication data error
Q172CPU
USB
PULLCH1
CH2
FRONT
SSCNET
RS-232
QJ71C24-R2QJ61BT-11
PULL
POWERQ25HCPU
USB
QJ71LP21-25QJ61CL12
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
PULL
MODERUNERR
USERBAT
BOOT
MODERUNERR
USERBAT
BOOT
Q64P
40 20 10 8 4 2 1 4 2 1
B RATESTATION NO.
ON
AJ65SBTB1-16DTDA DG +24V 24GDB SLD (FG)
PW L RUN L ERR X0 1 2 3 4 5 6 7 Y8 9 A B C D E F
YEYCYAY8X6X4X2X0
COM+X7X5X3X1
Y9 9B YD YF COM-
Note. An RS-422/RS-232 conversion cable is required to connect a PC to this module.Refer to the table below for connectable peripheral devices and compatible MELSEC PLC programming software. For details regarding compatible converters and cables, refer to the operation manuals for the peripheral device and the MELSEC PLC programming software being used.
AJ65BT-G4-S3
RS-422 interface
Peripheral device
MELSEC PLC programming software
2- 4.5 Mounting hole
113 114
Peripheral device connection modulePeripheral device connection moduleProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Features
RS-232 interface module
AJ65BT-R2
Unit: mm
Interface specificationTransmission methodSynchronization methodTransmission speed
Dataformat
Error detectionCommunication control (flow control)Transmission distanceReceive area in OSGeneral-purpose I/O specificationCC-Link station typeNo. of stations occupiedPower supply voltageCurrent consumptionEEPROM writingExternal dimensionsWeight (g)
RS-232 specification
Data link specification
Model name
Start bitData bitParity bitStop bit
AJ65BT-R2RS-232-compliant, 1 channel (A)
Full duplex communication methodAsynchronous method
300,600,1200,2400,4800,9600,19200bps (Selected by the RC-232 transmission specification setting switch)1
7/81 (yes)/0 (no)
1/2Odd/Even/None
DTR/DSR (ER/DR) controlDC1/DC3 control
15m5120 bytes
Input side: 24VDC (sink/source shared type) 2 pointsOutput side: Transistor output (sink type) 12/24 VDC 2-point terminal block (B) (C)
Intelligent device station1 station (RX/RY: 32 points each, RWr/RWw: 4 words each)
24VDCTypically 110mA (24VDC), 180mA (16.8V) maximum
100,000 times170 (W) x 80 (H) x 63.5 (D) mm
395g
123456789
Pin no. NameSignal code
Signal direction
Reception carrier detectionReception data
Transmission dataData terminal ready
Signal groundData set ready
Transmission requestClear to send
Not used
CDRD (RXD)SD (TXD)ER (DTR)
SGDR (DSR)RS (RTS)CS (CTS)
- -
(A) Specifications of the RS-232 interface for connecting external devices
(B) Specifications of general-purpose input of AJ65BT-R2
The following type of connector is mounted on the AJ65BT-R2 side; use a suitable connector on the connected side.
9-pin D-sub (female) screw type connector manufactured by DDK Ltd. 17JE-13090-37 (D23A)
Number of input pointsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. simultaneous input pointsON voltage/ON currentOFF voltage/OFF currentInput resistanceResponse timeWiring method for commonExternal connection method
Applicable wire sizeApplicable solderless terminal
AJ65BT-R2 External connection
DC
inpu
t (si
nk/s
ourc
e sh
ared
type
)
Tra
nsis
tor
outp
ut (
sink
type
)
AJ65BT-R2 External connection
Terminal Number
TB1TB2
Inte
grat
ed c
ircui
t
Signal nameXC
COM1
Terminal Number
TB3TB4
Signal nameXDNC
Number of output pointsIsolation methodRated load voltageRated load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ONOutput methodResponse timeExternal powersupply in the output areaSurge suppressionWiring method for commonExternal connection methodApplicable wire sizeApplicable solderless terminal
TerminalNumber
TB5TB6
SignalnameYC
COM2
TerminalNumber
TB7
Signalname
YD
(C) Specifications of general-purpose output of AJ65BT-R2
COM12
XD3 R
1 XC R
R
R
COM26
YD7L
5 YCL
DC24V
1 2 3 4
6 7 8 9
5
Inte
grat
ed c
ircui
t
One RS-232 channel is provided.
The general-purpose I/O function is also available.Two points are provided for each of general-purpose inputs and outputs.
Easy programming with the automatic buffer memory refresh function.The FROM/TO instruction can be used to write data to or read data from external devices, which makes programming easy.
Any given data can be sent to or received from external devices with the non-procedural communication function.
Related manualUser's Manual IB-66781 (13JL24)
2 pointsPhotocoupler isolation12/24VDC10.2 to 28.8VDC (with a ripple ratio of 5% or less)0.1A/point, 0.2A/common0.4A, 10msec or loess0.1mA or lower1.5VDC or lower (MAX) 0.1ASink typeOFF ON : 2msec or less ON OFF: 2msec or less10.2 to 28.8VDC (with a ripple rate of 5% or less), 50A or lower (TPY 24VDC/common), External load power supply is not included.Zener diode2 points 1 common (COM2)9-pin connector (I/O area) 7-point terminal block (M3.5 screws), Includes transmission circuit and module power supply terminal.0.75 to 2mm2
RAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805)
Part names and functions
External connection External dimensions
Performance specifications
AJ65BT-R2 External device
2 pointsPhotocoupler isolation24VDCApprox. 7mA19.2 to 28.8VDC (with a ripple ratio of 5% or less)
100%
14V/3.5mA or higher6V /1.7mA or lowerApprox. 3.3kOFF ON: 10msec or less ON OFF: 10msec or less2 points/1 common (COM1) sink/source shared type9-pin connector (I/O area) 7-point terminal block (M3.5 screws), Includes transmission circuit and module power supply terminal.0.75 to2mm2
RAV1.25 to 3.5, RAV2 to 3.5 (compliant to JIS C 2805)
RS-232 transmission specification setting switchThe RS-232 transmission details are specified.
Data link terminal block Connect the power supply and the twisted cable for the data link. (2-piece terminal block)
RS-232 interfaceThis is used for an RS-232 cable connected to an external device.
PWRUNL RUNL ERR.SDRD
Initialstatus
StatusOther
XC, XDYC, YDRS-232 SDRS-232 RDRS-232 ERR
Turns on when the power is normally supplied.Turns on when the module is normal, and turns off at a WDT error.Turns on when the network communication is normal.Turns on when the network communication is abnormal (e.g., CRC error).Flashing when sending data link data.Flashing when receiving data link data.Status of general-purpose inputs.Status of general-purpose outputs.Turns on when sending RS-232 data.Turns on when receiving RS-232 data.Turns on at an RS-232 transmission error, etc.
Terminal block for general-purpose input/outputThis is used for connecting I/O wires.
Reset switchPressing this makes the module return to the power-on status.
SW1 to 8
SW4
SW5
SW6
SW7
SW8
Number Setting item
Not used
Number of data bits
Parity bit enable/disable
Number of stop bits
Transmissionspeed
Status of setting switch
1
0
1
0
1
0
1
0
8
Enable
Even
2
7
Disable
Odd
1
SW
0: OFF 1: ON
ON OFF
2
0
0
1
1
0
0
1
3
0
0
0
0
1
1
1
300bps
600bps
1200bps
2400bps
4800bps
9600bps
19200bps
LED indication Transmission rate setting switchDescriptionLED name
Station number setting switchesThe station number of the module is set.
SDRDRSCSDRSGCDER
Signal codeSDRDRSCSDRSGCDER
Signal code
External device (DTE)AJ65BT-R2 side (DTE)
32786514
Pin No.
SDRDRSCSDRSGCDER
Signal codeSDRDRSCSDRSGCDER
Signal code
External device (DTE)AJ65BT-R2 side (DTE) Cable connection andsignal method
Cable connection andsignal method
32786514
Pin No.
Mode setting switchThe operating condition of the module is set.
No.0
1
D
NameOnline mode
(No automatic buffer memory refresh)Online mode
(With automatic buffer memory refresh)Hardware test mode
SettingCommunications are performed without the automatic buffer memory refresh function.Communications are performed with the
automatic buffer memory refresh function active.The module operation can be tested in this mode.
The following shows how to connect the AJ65BT-R2 and an external device via RS-232 interface. Example: DC code control and DTR/DSR signal control are possible.
Example: DC code control only is possible.
63.5
9.5
161170
4.5
71 804.
5
01234
5 to 9
156kbps625kbps2.5Mbps5Mbps
10MbpsSetting error
Settingnumber Transmission rate
2- 4.5 Mounting hole
RS-232 interface moduleRS-232 Interface moduleProduct information
115 116
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Features
Unit: mm
IBM PC/AT compatible PC
Programming language
Required free hard disk spaceDisk drive (necessary at installation)
Operating system (OS)
Item Description
Required memory32MB or more64MB or more
Operating system (OS)Description
*1: A CC-Link Ver. 2 board and Ver. 1 board (A80BDE-J61BT11/13) cannot be used together in the same PC.
Station typeNo. of occupied stations (for local station)No. of mountable modulesSlotNumber of occupied slotsCurrent consumption (5VDC)External dimensionsWeight (kg)
Model name Q80BD-J61BT11NMaster station, standby master station or local station
1 to 4 stations (changed using the parameter settings of Utilities)Up tp 4 modules *1
IBM PC/AT compatible PC PCI bus (5VDC, 32-bit bus, basic clock: 33MHz, PCI Standard Rev. 2.2)1 slot0.56A
158 (W) x 121 (H) x 18 (D) mm0.11kg
Required memory128MB or more128MB or more
Description
PC Interface board
Q80BD-J61BT11N
Part names and functions
External dimensions
Performance specificattions
Operating environment
Applicable operating system and the corresponding required PC performance
SW1DNC-CCBD2-B
The CC-Link Ver. 2 compatible PC interface board allows you to build a an IBM PC/AT compatible PC into a CC-Link system. By mounting a CC-Link Ver. 2 board onto a IBM PC/AT compatible PC, the IBM PC/AT compatible PC can be used as a Ver. 2 compatible master station, standby master station or local station. (Usable in Ver.1 systems)
The board is QCPU (Q mode) multi-CPU system compatible.Communication with each QCPU (Q mode) of a multi-CPU system is possible by utilizing the logic station number specification using CC-Link Ver. 2 Utilities.
Related manualUser's Manual SH(NA)-080527 (13JR77)
CC-Link Ver.2 utility, device monitor utility, and user's manual (PDF) are included in
the CD-ROM (SW1DNC-CCBD2-B) supplied with the board.
The parameters can be easily set.The parameters required for CC-Link system operation can be easily set using CC-Link Ver. 2 Utilities.
The IBM PC/AT compatible PC displays CC-Link system related test and monitor information.The CC-Link system test and monitor status information can be easily displayed using the IBM PC/AT compatible PC.
User program functions are provided.The provided Microsoft Visual C++ , Microsoft Visual Basic , Microsoft Visual C++ .NET 2003 and Microsoft Visual Basic .NET 2003 functions allow you to remotely control remote I/O stations, remote device stations, intelligent device stations and local stations, perform read and write operations and easily develop user programs.Examples: Remote I/O station input X and output Y ON/OFF control
Remote device station (analog module) analog voltage output controlIntelligent device station (RS-232C module) communication control
IBM-PC/AT-compatible personal computer with one or more PCI bus slots, satisfying the specifications described below in "Applicable operating system and the corresponding required PC performance" *2,3
Microsoft Windows NT Workstation Operating System Version 4.0 (English version) orMicrosoft Windows 2000 Professional Operating System (English version) orMicrosoft Windows XP Professional Operating System (English version) or
Microsoft Windows XP Home Edition Operating System (English version) *4,5
Microsoft Visual Basic 5.0 (English version) or Microsoft Visual Basic 6.0 (English version) or Microsoft Visual C++ 5.0 (English version) or Microsoft Visual C++ 6.0 (English version) or Microsoft Visual C++ .NET 2003 or Microsoft Visual Basic .NET 2003 *6
20MB or higherCD-ROM disc drive
*2: This product does not work with a multiprocessor IBM-PC/AT-compatible personal computer, as the driver is incompatible.*3: This board can be used in IBM PC/AT compatible PCs which conform to the PCI standard.
Using a PC not compliant with the PCI standard may result in a problem due to bad electrical contact, erroneous operation or other reason.*4: Mitsubishi Electric Corporation onerously discloses "Open Field Network CC-Link Compatible Product Development Reference Manual CC-Link Ver.2 Q80BD-J61BT11N
Driver" (L(NA)-080601ENG) as information to develop drivers compatible with various operating systems.For details, refer to "Open Field Network CC-Link, CC-Link/LT Compatible Product Development Guidebook" (L(NA)-08052E-A).
*5: Both Japanese and English version of utilities are included in the supplied CD-ROM (SW1DNC-CCBD2-B).For Japanese OS, the Japanese version of utility, and for English OS, the English version of utility is installed. For other than Japanese or English OS, the English version of utility is installed, but an operation is not guaranteed.
*6: Visual Basic Ver.5.0 and Visual C++ Ver.5.0 cannot be used when Windows 2000 Professional or Windows XP is used.
Windows NT Workstation 4.0Windows 2000 Professional
CPUPentium 133Hz or higherPentium 133Hz or higher
Windows XP ProfessionalWindows XP Home Edition
CPUPentium 300Hz or higherPentium 300Hz or higher
BDNO.
BD808C182G51
SLDDGDBDA
SD RD
RUNERR.
Operation indicator LEDs
Terminal block for data linkChannel number setting switch
ERR
RD
RUN
SD
DA
DB
DG
SLD
CC-Link Ver.2 utility (supplied)
Device monitor utility (supplied)
User's manual
147153
19
9990
141
121
158
BDNO.
BD808C182G51
SLDDGDBDA
SD RD
RUNERR.
Normal modeRUN
ERR.
SD
RD
Error modeRUN
ERR.
SD
RD
OFF
ONOFF
ONFlicker
OFF
ONOFF
ON
FlickerONOFFOFFONOFFONOFFON
A WDT error has occurred, or the board is being reset. Operating normally.No communication error has occurred, or the board is being reset.All stations are faulty.There is a faulty station or station No. is duplicated.No data have been transmitted, or the board is being reset. Data are being transmitted.No data have been received, or the board is being reset.Data are being received.
Indicates the board is in the error mode.
No error
No OS start error has occurred.An OS start error has occurred.No driver response error has occurred.A driver response error has occurred.No PCI bus error has occurred.A PCI bus error has occurred.
LED name DescriptionStatus
RemarkBoardNo.0123
ChannelNo.81828384
OFFONOFFON
OFFOFFONON
Switch1 2
Set the channel number of the CC-Link Ver.2 board.
If 2 or more CC-Link Ver.2 boards are mounted, prevent duplication of the board numbers.
BDNO.
Default setting
Both Japanese and English version of user's manuals (PDF) are included.
The Device Monitor Utility software package provides the following functions: Batch monitor and 16-point registration monitor Device value change
The CC-Link Ver.2 Utility software package provides
the following functions: Board information display Line monitor (other stations) Memory and I/O diagnosis Test Parameter setting Target setting for multi-CPU system compatible PLC communication
etc.
PC Interface boardRemote I/O moduleProduct information
117 118
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Lineup of repeater modules covers a wide range of CC-Link applications and improves flexibility in network constructions.
Overview Model names
Product name
Low profile waterproof type repeater hub module
Spring clamp terminal block type repeater hub module
Repeater (T-branch) module
Optical repeater module
Spatial optical repeater module
AJ65FBTA-RPH
AJ65BTS-RPH
AJ65SBT-RPT
AJ65SBT-RPS
AJ65SBT-RPG
AJ65BT-RPI-10A
AJ65BT-RPI-10B
Model name
User's Manual IB-0800288 (13JP55)
User's Manual IB-0800346 (13JP97)
User's Manual IB-0800078 (13JQ81)
User's Manual IB-0800089 (13JQ85)
User's Manual IB-0800090 (13JQ86)
Related manual
This module allows star topology wiring.
Wireless transmission via infrared light enables interconnection with the devices such as slave devices mounted on mobile objects, for which physical cable connection is difficult.
Using optical fiber cables extend the transmission distance and prevent problems caused by transmission line noise. T-branch wiring is also available.
T-branch wiring is available for use of CC-Link at any transmission speed, and the transmission distance can be extended.
Low profile waterproof type repeater hub moduleAJ65FBTA-RPH
Repeater (T-branch) moduleAJ65SBT-RPT
Spatial optical repeater moduleAJ65BT-RPI-10A/AJ65BT-RPI-10B
Optical repeater moduleAJ65SBT-RPS/AJ65SBT-RPG
Spring clamp terminal block type repeater hub moduleAJ65BTS-RPH
Up to 64 modules of remote I/O stations, remote device stations, local stations, standby master stations, intelligent device stations and repeaters can be connected within one segment*1. The number of slave stations that can be controlled by one master station is unchanged regardless of whether repeater(s) are used or not.
By using repeater modules, the master station can communicate with slave stations on up to 10 stages away from the master station (when using AJ65SBT-RPT). (The maximum number of accessible states is 3 for AJ65SBT-RPS, and 2 for AJ65SBT-RPG, AJ65SBT-RPI-10A or AJ65SBT-RPI-10B.)
*1: A block of devices connected from one terminal resistor to another is referred to as a segment in the CC-Link system that uses repeater(s).
P.125
P.129
P.127
P.121 P.123
119 120
Repeater moduleRepeater moduleProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Features
Low profile waterproof type repeater hub module
AJ65FBTA-RPH
Model name
Remote station number
Remote type
No. of occupied stations
Transmission rate
No. of slave stations
Connection position
Max. segment stages
Max. cable length (total)
Terminating resistor (integrated)
Connector
Module orientation
Module mounting screw
Power supply voltage
User's Manual IB-0800288(13JP55)
Hub only
Combination of hub and AJ65SBT-RPT
Combination of hub and AJ65SBT-RPS/RPG and AJ65BT-RPI
2 stages
3 stages
2 stages
Unit: mm
The following figure shows how to connect AJ65FBTA-RPH to the CC-Link system with cables.Star topology network of 8 branch lines is configurable.
Up to 8 branch lines (segments) can be connected in star topology and used at any transmission speed available for the CC-Link.
Max. transmission distance of 1200m per branch, and further extendable by connecting 2 stagesThe transmission distance can be extended up to 1200m (at 156kbps) per branch line (segment). The overall length can be more increased if a hub is connected to each branch. Up to 64 slave stations (local, remote I/O, remote device and/or intelligent device stations, etc.) are connectable. This module can be used together with other conventional repeater modules, enabling flexible networking.
Waterproof structure permits external installation.With IP67 waterproof and dustproof design, external installation is available, reducing the installation works and cost.
Easy to add modules to the existing systemSlave stations can be easily added without rewiring the existing system, realizing flexible network construction.Also, when any network problem has occurred, this repeater module allows module replacement by each branch line.
Performance specifications
Related manual
Part names and functions
System configuration
External dimensions
Module connection
(1) Connect a terminating resistor to the module connected to the end of the AJ65FBTA-RPH trunk line.Select a suitable resistor that is applicable to the communication cable type.For details, refer to the relevant module manual.
(2) When the AJ65FBTA-RPH is connected to other than the trunk line ends, turn off the terminating resistor setting switch.Connect the shielded wire of the CC-Link dedicated cable to "SLD" of each module, and ground both cable ends via "FG".Note that "SLD" and "FG" are connected inside the module.
(3) When the AJ65FBTA-RPH is connected to the trunk line end, turn on the terminating resistor setting switch.Select a suitable resistor that is applicable to the communication cable type.For details, refer to the relevant manual.Connect the shielded wire of the CC-Link dedicated cable to "SLD" of each module, and ground both cable ends via "FG".Note that "SLD" and "FG" are connected inside the module.
(4) Connect a 100 terminating resistor to the module connected to the end of each AJ65FBTA-RPH branch line.For details refer to the relevant module manual.
(5) The branch line's terminating resistor (110 ) is integrated in the AJ65FBTA-RPH. (Switch setting not required)Connect the shielded wire of the CC-Link dedicated cable to “SLD” of each module, and ground both cable ends via "FG".Note that "SLD" and "FG" are connected inside the module.
AJ65FBTA-RPH
- (No station number)
- (No type restrictions)
- (does not occupy any stations)
10M/5M/2.5M/625k/156kbps (Transmission rate between trunk line and branch line is determined automatically)
Total of 64 stations connectable to trunk and branch lines (For details, see the CC-Link specs.)
Trunk line: No restrictions (based on the CC-Link specs.), Branch line: Branch line end (segment end)
Trunk line: The max. length for each transmission rate, Branch line: The max. length for the transmission rate of each branch
Trunk line: 130 , 110 , no resistance (dip switch setting) Branch line: Fixed at 110
M12 waterproof connectors (IEC947-5-2)
No restrictions (Available in 6 orientations)
M4 mounting screws, 2-4.5mm x 6mm oblong holes for M4 mounting screws
24VDC externally supplied (20.4V to 26.4V, ripples within ±5%)
*1: It is necessary to match the transmission speed of each segment to that of the master station.
*2: Two more stages can be connected as segments.*3: Use a terminating resistance of 110 for the AJ65FBTA-RPH. Use of 130 is not
allowed.
Master station *1
[Segment]
Remote I/O station
Remote I/O station
Local station
Remote I/O station
Remote device station
Remote device station
Remote device station
Intelligent device station
Intelligent device station
Terminating resistor(Required)
Terminating resistor(Required)
Repeater (AJ65FBTA-RPH)
Repeater (AJ65FBTA-RPH) Repeater (AJ65FBTA-RPH)
[Segment (1st stage)]
[Segment (2nd stage)]*2
6
4.3
6
60.3 48+1
0
50
26.518.3
13.8
+10 34+1
0
32
21.74.1
35
6
+0.5 0
2525
2524
67.5
21.3
200+
1 0
192±
1
2-4.5 x 6 oblong holes (for M4 mounting screws)
(M4 mounting screws)
Master station Remote I/Ostation
Intelligent device station
Repeater (AJ65FBTA-RPH)
Repeater (AJ65FBTA-RPH)
Remote I/Ostation
Remote I/Ostation
(1)
(4)
(3)
(2)
(5)
Communication adapter (front side)
Communication adapter connector
Communication adapter (back side)
Connector
ON
TERMINATION110Ω 130Ω
Communication adapter
Mounting screw for communication adaptor
FG metal fittingsModule fixing hole
terminating resistor setting
OFFOFFONON
OFFONOFFON
Dip switch1
Dip switch2
Description
ON
24 1B RATE
1 2
Transmission rate setting switch The transmission speed of the module is set. (Factory default: 0)Be sure to set it as shown in the right table.Transmission speeds of the trunk and branch lines will be automatically matched.
Waterproof connector for transmission lineLINK IN (left side) LINK OUT (right side)
Operation indicator LEDsThe status of the module can be checked by the on/off status of the LEDs.
POWER
RUN
SD
RD
ERR.
156k,625k,2.5M,5M,10ML1 RDto L8 RD
LED name Description
Settingvalue
156kbps625kbps2.5Mbps5Mbps10Mbps
Transmissionrate
Status of setting switch2
OFFOFFONONOFF
1OFFONOFFONOFF
4OFFOFFOFFOFFON
01234
ON: Power supply is onOFF: Power supply is off ON: Operation is normal.OFF: Module is not operable.ON: Data are being sent to LINK IN or LINK OUT of trunk lineOFF: No data are being sent to LINK IN or LINK OUT of trunk lineON: Data are being received to LINK IN or LINK OUT of trunk lineOFF: No data are being received to LINK IN or LINK OUT of trunk lineON: Invalid transmission rate setting, communication errorFlashing: Terminating resistor is missing, or noise affects the module or CC-Link dedicated cable.OFF: Operation is normal.A LED showing the transmission rate set by the Transmission rate setting switch is lit.ON: Data are being received from LINK1 to 8 of branch lines.OFF: No data are being received from LINK1 to 8 of branch lines.
Waterproof connector for transmission lines
LINK 1 to 8
Waterproof connector for power-supply line
UNIT POWER
No terminal resistor110 resistor On130 resistor OnSetting prohibited
Terminating resistor 110(Required)*3
Terminating resistance 110 ON specified by terminating resistance selector switch (Required) *3
Terminating resistor 110 (Required)*3
Terminating resistor 110 (Required)*3
Terminating resistor 110 (Required)*3
Terminating resistor 110 (Required)*3
121 122
Repeater moduleRepeater moduleProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Features
Spring clamp terminal block type repeater hub module
AJ65BTS-RPH
User's Manual IB-0800346(13JP97)
Performance specifications
Related manual
Part names and functions
System configuration
External dimensions
Module connection
Station number
CC-Link station type
Number of occupied stations
Transmission rate
Max. No. of modules connected to the trunk line
Connection position
Max. number of stages connected
to configure segment
Terminating resistor
Terminal block
Mounting orientation
Module installation screw
Applicable DIN rail
Power supply
Terminal block type
Applicable cable size
Voltage
Current
Item
AJ65BTS-RPH only
Combination of AJ65BTS-RPH and AJ65SBT-RPT
Combination of AJ65BTS-RPH and (AJ65FBTA-RPH and AJ65SBT-RPS/RPG and AJ65BT-RPI)
2nd stage
3nd stage
2nd stage
Unit: mm
Star-topology wiring (T-branch) with 8 branch lines (segments) available in CC-Link systemBy placing the AJ65BTS-RPH between modules of the CC-Link system, star-topology wiring (T-branch) with up to 8 branch lines (segments) can be used in the CC-Link system of all transmission rates (10Mbps, 5Mbps, 2.5Mbps, 625kbps, and 156kbps).
The transmission distance in CC-Link systemUse of this module enables the transmission distance of the CC-Link system to be extended.In addition, use of multiple modules enables the transmissiondistance of the CC-Link system to be extended up to 2 stages.
Energy saving realized by adoption of a spring clamp terminal blockThe AJ65BTS-RPH has adopted a spring clamp terminal block.Because screw tightening is not needed, working steps can be reduced.The terminal block can be installed to or removed from the module, which reduces the maintenance cost and improves the maintainability.All the operation and wiring parts are placed on the module front,allowing easier operation and wiring.
Improved maintenability by system separationBy using the AJ65BTS-RPH, any of the systems can be separated and error location can be identified quickly.This prevents the whole system from being seriously affected by an error.
AJ65BTS-RPH
- (none)
- (none)
0 (none)
Can select from 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps
64
Trunk line side :No restriction (compliant with the CC-Link specifications) Branch line side :Connect to the end of the branch line (segment end)
Trunk line side :110 /130 Branch line side :110
Spring clamp terminal block
AWG #24 to 12, 0.5 to 1.78mm2 single cable, 0.2 to 2.5mm2 stranded cable
No restriction (mountable in six orientations)
M4 mounting screw
TH35-7.5Fe, TH35-7.5AI (conforming to IEC 60715)
24V DC external power supply (20.4 to 26.4V, ripple within ±5%)
0.36A (TYP. 24V DC)
*1: It is necessary to match the transmission speed of each segment to that of the master station.
*2: Two more stages can be connected as segments.*3: Use a terminating resistance of 110 for the AJ65FBTA-RPH. Use of 130 is not
allowed.
(1) For the segment connected to the trunk line side of the AJ65BTS-RPH, connect a terminating resistor to the module connected at the end.Select a type for terminating resistor in accordance with the type of the connected communication cable.For details, refer to the manual of the module connected.
(2) Do not connect any terminating resistor to the AJ65BTS-RPH when the trunk line side is connected to a station that is not located at the end of the segment.In addition, connect the shielding wire of the CC-Link dedicated cable to “SLD” of each module, and ground both ends via “FG.” The interval between SLD and FG is connected in the module in advance.
(3) Connect the included terminating resistor to the AJ65BTS-RPH when the trunk line side is connected to a station that is located at the end of the segment.Select a type for terminating resistor in accordance with the type of the connected communication cable.In addition, connect the shielding wire of the CC-Link dedicated cable to “SLD” of each module, and ground both ends via “FG.” The interval between SLD and FG is connected in the module in advance.
(4) Connect the included 110 terminating resistor to the module located at the end of a segment when the branch line side of the AJ65BTS-RPH is connected to the segment.For the connection of terminal resistor, refer to the manual of the module connected.
(5) For the branch line side of the AJ65BTS-RPH, use the incorporated 110Ω terminating resistor.In addition, connect the shielding wire of the CC-Link dedicated cable to “SLD” of each module, and ground both ends via “FG.”Note that SLD and FG are connected to each other in the module.
Mounting pitch 188.4±0.2
37
197.5
Mou
ntin
g pi
tch
56±0
.2
6520
.5
28.545
.5
9
Transmission rate setting switch The transmission speed of the module is set. (Factory default: 0)Be sure to set it as shown in the right table.Transmission speeds of the trunk and branch lines will be automatically matched.
Power terminal blockConnects the module power supply (24V DC) and the ground cable (FG: Functional Ground).
Communication terminal block (Trunk line side)Connects the transmission lines on the trunk line side (LINK IN/OUT).
Communication terminal block (Branch line side)Connects the transmission lines on the branch line side (LINK 1 to 8).
Operation indicator LEDsThe status of the module can be checked by the on/off status of the LEDs.
POWER
RUN
SDLINK IN/OUTRDLINK IN/OUTERR.
RDLINK 1 to 8
LED name Description
Settingvalue
156kbps625kbps2.5Mbps5Mbps10Mbps
Cannot be set.If set to other than 0 to 4, the ERR.LED
is turned on and data are not transferred.
Status of setting switch
01234
Otherthan0 to 4
ON: Power supply onOFF: Power supply offON: Module is operating normallyOFF: Module is not operating normallyON: Data are being sent to the LINK IN or LINK OUT of the trunk lineOFF: Data are not being sent to the LINK IN or LINK OUT of the trunk lineON: Data are being received from the LINK IN or LINK OUT of the trunk lineOFF: Data are not being received from the LINK IN or LINK OUT of the trunk lineON: Transmission rate setting out-of-range error or communication error occurredFlickering : Terminating resistor is missing. The module and CC-Link
cables are affected by noise. Or the transmission rate was changed after power up.
OFF: Module is operating normallyON: Data are being received from the LINK1 to 8 of the branch lineOFF: Data are not being received from the LINK1 to 8 of the branch line
+24V24GNC
FG FG
+24V24GNC
FG FG
DADBDGSLD
DADBDGSLD
DADBDGSLD
Module fixing hole
Terminal block fixing screw
The following figure shows how to connect AJ65BTS-RPH to the CC-Link system with cables.
Master station Remote I/Ostation
Intelligent device station
Repeater (AJ65FBTA-RPH)
Repeater (AJ65FBTA-RPH)
Remote I/Ostation
Remote I/Ostation
(1)
(4)
(3)(2)
(5)
Master station *1
Remote I/O station
Remote I/O station
Local station
Remote I/O station
Remote device station
Remote device station
Remote device station
Intelligent device station
Intelligent device station
Terminating resistor(Required)
Terminating resistor(Required)
Repeater (AJ65BTS-RPH)
Repeater (AJ65BTS-RPH) Repeater (AJ65BTS-RPH)
[Segment]
[Segment (1st stage)]
[Segment (2nd stage)]*2
2- 4.5
Terminating resistor,110 (Indispensable)*3
Terminating resistor,110 (built-in)*3
Terminating resistor,110 (Indispensable)*3
Terminating resistor,110 (Indispensable)*3
Terminating resistor,110 (Indispensable)*3
Terminating resistor,110 (Indispensable)*3
123 124
Repeater moduleProduct information
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Repeater module
Features
Repeater (T-Branch) module
AJ65SBT-RPT
Unit: mm
User's Manual IB-0800078 (13JQ81)
Max. segment stages
Maximum transmission distance
of each segment
No. of occupied stations
Station numbers that can be set
Power supply voltage
Current consumption
External dimensions
Weight (kg)
Model name
10
Varies depending on the transmission speed.
The max. transmission distance between repeaters is the same as that of a general CC-Link system (with no repeater).
- (does not occupy any stations)
No station number
20.4 to 26.4VDC
0.06 A (at TYP 24VDC)
87.3 (W) X 54 (H) X 40 (D) mm
0.2
AJ65SBT-RPT
T-branch wiring in the CC-Link system is available.Connecting this module between other CC-Link system modules enables T-branch wiring at any CC-Link system transmission speed (10Mbps, 5Mbps, 2.5Mbps, 625kbps or 156kbps).
The transmission distance of the CC-Link system can be extended.Use of this module allows extension of the transmission distance in the CC-Link system.Extensions of up to 10 stages are possible by using multiple AJ65SBT-RPT modules.
Related manual
Performance specifications
Part names and functions
System configuration
External dimensions
Module connection
Transmission rate setting switchThe transmission speed of the module is set.(Factory default: 0)Be sure to set it as shown in the table below.Any other setting will light up the “ERR.” LED.
Operation LEDsThe status of the module can be checked by the on/off status of the LED.
PW
TEST
ERR.
SD1
RD1
SD2
RD2
LED name During hardware test Normal operation
Settingvalue
156kbps625kbps2.5Mbps5Mbps10Mbps
Transmissionrate
Status of setting switch2
OFFOFFONONOFF
1OFFONOFFONOFF
4OFFOFFOFFOFFON
01234
Reset switchPressing this switch resets the module's hardware. (Factory default: OFF)
AJ65SBT-RPT
ON
SD1 RD1 SD2 RD2PW TEST ERR.
IN OUT
DA1 DG1 +24V 24G
DB1 SLDIN
DA2 DG2
DB2 SLD (FG)
NC NC
OUT(FG)
124TEST
B RATE
RESET
*1: A repeater is used to make connection between different segments and extend the CC-Link system.
*2: In the CC-Link system using repealers, a block of devices connected from one terminating resistor to another is referred to as a segment. (The conventional CC-Link system is made up of one segment.)
*3: It is necessary to match the transmission speed of each segment device to that of the master station.
IMPORTANTCC-Link dedicated cables of different specifications can be used for each of different segments. However, CC-Link dedicated cables within the same segment must have the same specifications. If not, normal data transmission is not guaranteed.
POINT• Always connect terminating resistors to modules on both segment ends.
A terminating resistor should be connected between DA and DB (DA1 and DB1, or DA2 and DB2 for the AJ65SBT-RPT).(Terminating resistors are supplied with the module.)
• The terminating resistor varies depending on the type of the cable used.For details, refer to the User's Manual of the master module.
• Connect the shielded wire of the CC-Link dedicated cable to “SLD” of each module, and ground both cable ends via “FG”.Note that “SLD” and “FG” are connected inside the module.
Remote I/O station
Remote I/O station
Remote I/O station
Local station
Remote device station
Remote device station
Repeater(AJ65SBT-RPT)
Repeater (AJ65SBT-RPT)
Repeater (AJ65SBT-RPT)
Intelligent device station
Intelligent device station
Master station
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
Terminating resistor(Required)
[Segment]
IN OUT
IN OUT
IN OUT
[Segment (first level)]
[Segment (first level)]
[Segment (second level)]
AJ65SBT-RPT
SD1 RD1 SD2 RD2
DA1 DG1 +24V 24G
DB1 SLD (FG)
124
ON
TESTB RATE
87.3
2-4.5 x 5.1 mounting hole (M4 mounting screw)
16.5
504
40
78.3 (Mounting pitch)+1 0
DA2 DG2
DB2 SLDIN (FG)
NC NC
OUT
RESETPW TEST ERR.
IN OUT
Terminatingresistor
Terminatingresistor
Terminatingresistor Terminating
resistor
Master module AJ65SBT-RPT Remote I/O module
Local module
DA
DB
DG
SLD
FG
DA
DB
DG
FG
SLDCC-Link dedicated cable CC-Link dedicated cable
CC-Link dedicated cable CC-Link dedicated cable
Terminatingresistor
Terminatingresistor
Terminatingresistor
CC-Link dedicated cable CC-Link dedicated cable
Terminatingresistor
CC-Link dedicated cable
AJ65SBT-RPT
DA
DB
DG
FG
SLD
DA1
DB1
DG1
FG
SLD
DA2
DB2
DG2
FG
SLD
AJ65SBT-RPT
DA
DB
DG
FG
SLD
DA
DB
DG
FG
SLD
DA1
DB1
DG1
FG
SLD
DA2
DB2
DG2
FG
SLD
DA1
DB1
DG1
FG
SLD
DA2
DB2
DG2
FG
SLD
IN side terminal blockThis terminal block is used to connect the CC-Link dedicated cable on the side where the power supply and master station exist.
DIN rail hookHook for mounting the module to the DIN rail.When mounting, press the center of the hook by your finger until it clicks.
OUT side terminal blockThis terminal block is used to connect the CC-Link dedicated cable on the side where the master station does not exist.
ON: Power supply is on.OFF: Power supply is off, or the reset switch is pressed.ON: A hardware test is performed. OFF: CommunicatingON: Hardware errorSwitch setting is not correct.Flashing: Switch setting was changed during operation.OFF: NormalFlashing: Circuit is normal.OFF: Circuit is faulty.Flashing: IN side circuit is normal.OFF: IN side circuit is faulty.Flashing: Circuit is normal.OFF: Outside circuit is faulty.Flashing: Circuit is normal.OFF: Outside circuit is faulty.
ON: Communication errorSwitch setting is not correct.Flashing: Switch setting was changed during operation.OFF: Normal communicationFlashing: Sending data to IN sideOFF: Not sending data to IN sideFlashing: Receiving data from IN sideOFF: Not receiving data from IN sideFlashing: Sending data to OUT sideOFF: Not sending data to OUT sideFlashing: Receiving data from OUT sideOFF: Not receiving data from OUT side
Test switchThis is used to set the operating condition of the module. (Factory default: OFF)
Switch statusONOFF
Operation statusHardware test
Normal operation
7.5
7.9
About 105°
DIN rail
The following figure shows how to connect AJ65SBT-RPT to the CC-Link system with cables.
POINTThe settings of the test switch and the transmission speed setting switch are made effective when to the module is powered ON from OFF or the reset switch is turned off.If any setting has been changed with the module power ON, perform the operation again.
125 126
Repeater moduleProduct informationRepeater module
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Features
Optical repeater module
AJ65SBT-RPSAJ65SBT-RPG
Unit: mm
User's Manual IB-0800089 (13JQ85)
Common specification
CC-Link communication specification
Optical communication specification
Model name
External dimensions
Weight (kg)
Supplied parts
Max. number of connectable stages per system
Number of stations occupied
Connection cable
Applicable connector
Maximum transmission distance of
optical fiber cable between repeaters
Voltage
CurrentPowersupply
AJ65SBT-RPS
3 stages 2 stages
QSI-185/230
CA7003 CA9103S
1000m
GI-50/125
2000m
SI-200/220
500m
AJ65SBT-RPG
The transmission distance of the CC-Link system can be extended.Using pairs of the same models, AJ65SBT-RPS (for SI/QSI type optical fiber cable) or AJ65SBT-RPG (for GI type optical fiber cable), allows extension of the transmission distance in the CC-Link system.Extensions of up to 3 stages are possible by using multiple pairs of modules (up to 2 stages for the AJ65SBT-RPG).
T-branch wiring in the CC-Link system is available.Connecting these modules between other CC-Link system modules enables T-branch wiring.
Stable and noise-tolerant systemUsing optical fiber cables for branching or extension prevents problems caused by noise, improving the system stability.
Related manual
Performance specifications
Part names and functions
System configuration Module connection
External dimensions
20.4 to 26.4VDC
0.06A (at TYP 24VDC)
118 (W) X 54 (H) X 40 (D) mm
0.2
Terminal resistors (110 to 1, 130 to 1)
- (does not occupy any stations)
DB
DA
SLD
DG +24V 24G
(FG)
PW TEST ERR.
4 2 1B RATE
TEST
MITSUBISHI AJ65SBT-RPS
ON
SD RD SD RD
TWI. OPT.
OUT IN
Transmission rate setting switchThe transmission rate of the module is set.(Factory default: 0)Be sure to set it as shown in the table below.Any other setting will light up the “ERR.” LED.
Operation indocator LEDs The status of the module can be checked by the on/off status of the LED.
PW
TEST
ERR.
TWI.SD
TWI.RD
OPT.SD
OPT.RD
LED name At hardware test At normal operation
Settingnumber
156kbps625kbps2.5Mbps5Mbps10Mbps
Transmissionrate
Status of setting switch2
OFFOFFONONOFF
1OFFONOFFONOFF
4OFFOFFOFFOFFON
01234
POINTThe settings of the test switch and the transmission speed setting switch are made effective when the module is powered ON from OFF. If any setting has been changed with the module power ON, perform the operation again.
*1: A repeater is used to make connection between different segments and extend the CC-Link system.
*2: In the CC-Link system using repealers, a block of devices connected from one terminating resistor to another is referred to as a segment. (The conventional CC-Link system is made up of one segment.)
*3: It is necessary to match the transmission speed of each segment device to that of the master station.
*4: Up to 3 stages can be added to a system. (Up to 2 stages for use of the AJ65SBT-RPG)
IMPORTANTCC-Link dedicated cables within the same segment must have the same specifications. If not, normal data transmission is not guaranteed.
POINT• Always connect terminating resistors to modules on both segment ends.
A terminating resistor should be connected between DA and DB.(Terminating resistors are supplied with the module.)
• The terminating resistor varies depending on the type of the cable used.For details, refer to the User’s Manual of the master module.
• Connect the shielded wire of the CC-Link dedicated cable to “SLD” of each module, and ground both cable ends via “FG”.Note that “SLD” and “FG” are connected inside the module.
Terminal blockThis terminal block is used for connecting the power supply and CC-Link dedicated cables.
DIN rail mounting hookThis hook is used to mount the module on the DIN rail.
Optical interface
ON: Power supply is on.OFF: Power supply is off.ON: A hardware test is being performed.OFF: CommunicatingON: Hardware errorSwitch setting is not correct.Flashing: Switch setting has been changed during operation.OFF: NormalFlashing: Circuit is normal.OFF: Circuit is faulty.Flashing: CC-Link side circuit is normal.OFF: Optical communication side circuit is faulty.Flashing: Circuit is normal.
OFF: Circuit is faulty.
Flashing: CC-Link side circuit is normal.OFF: Optical communication side circuit is faulty.
ON: Communication errorSwitch setting is not correct.
OFF: Normal communicationFlashing: Sending data to CC-Link sideOFF: Not sending data to CC-Link sideFlashing: Receiving data from CC-ink sideOFF: Not receiving data from CC-Link sideFlashing: Sending data to optical communication sideOFF: Not sending data to optical communication sideFlashing: Receiving data from optical communication sideOFF: Not receiving data from optical communication side
Test switchThis is used to set the operating condition of the module. (Factory default: OFF)
Switch statusONOFF
Operation statusHardware test
Normal operation
The following figure shows how to connect AJ65SBT-RPS/RPG to the CC-Link system with cables.
Remote I/O station
Remote I/O station
Master station*3
Remote devicestation
Intelligent device station
Intelligent device station
Remote devicestation
Repeater*1
(AJ65SBT-RPS/RPG)
Remote I/O station
Remote I/O station Remote I/O station
[Segment *2]
[Segment (1st stage)]
[Segment (1st stage)]
[Segment (2ns stage)*4]
Repeater*1
(AJ65SBT-RPS/RPG)
Repeater*1
(AJ65SBT-RPS/RPG)
Repeater*1
(AJ65SBT-RPS/RPG)
Repeater*1
(AJ65SBT-RPS/RPG)
: Terminating resistor (Required)
: Optical fiber cable
: CC-Link dedicated cable
Local station
Combinations of optical repeater modules and optical fiber cablesThe optical repeater modules can be used in the following combinations with optical fiber cable.
AJ65SBT-RPS
AJ65SBT-RPG
Optical repeater module Optical fiber cableSI-type optical fiber cable (maximum extension distance of cable: 500 m)
QSI-type optical fiber cable (maximum extension distance of cable: 1000 m)GI-type optical fiber cable (maximum extension distance of cable: 2000 m)
DB
DA
SLD
DG +24V 24G
(FG)
PW TEST ERR.
4 2 1B RATE
TEST
MITSUBISHI AJ65SBT-RPS
ON
2-4.5 x 5.1 mounting hole (M4 mounting screw)
118
16.5
504
109 (Mounting pitch)+10
40
SD RD SD RD
TWI. OPT.
OUT IN
7.5
7.9
About 105°
DIN rail
Terminatingresistor
Terminatingresistor
Terminatingresistor
Terminatingresistor
Master module Remote module
Local module
AJ65SBT-RPS/RPG
DA
DB
DG
SLD
FG
DA
DB
DG
FG
SLDCC-Link dedicated cable CC-Link dedicated cable
CC-Link dedicated cable
DA
DB
DG
FG
SLD
DA
DB
DG
FG
SLD
DA
DB
DG
FG
SLD
Optical fiber cable
AJ65SBT-RPS/RPG
Optical interface
Optical interface
127 128
Repeater moduleProduct informationRepeater module
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
Features
Spatial optical repeater module
AJ65BT-RPI-10AAJ65BT-RPI-10B
User's Manual IB-0800090 (13JQ86)
Common specification
Specially noted general specification
CC-Link communication specificationOpticalcommunication specification
Model name
Powersupply
VoltageCurrent
External dimensionsWeight (kg)Transmission rateMax. No. of connectablestagesNo. of occupied stationsOptical transmission distanceAngle of beam spread (°)
Modulation frequency
Modulation methodAmbient illumination *
AJ65BT-RPI-10A AJ65BT-RPI-10B
* Reference values (based on JIS Z9110) of ambient illumination are shown below.* l Illumination required for work using visual attention in a plant: 3000 to 1500 lx* Illumination required for work in an office: 2000 to 750 lx
20.4 to 26.4VDC0.137 A (at TYP 24VDC)
161 (W) X 100 (H) X 57.5 (D) mm0.5
2.5M/625k/156kbps2 stages
When the monitoring function is used: 1 (remote I/O station), when the monitoring function is not used: 0 (no station)0 to 100m
When the optical transmission distance is 0 to 50 m: Total angle ±2When the optical transmission distance is 50 to 100 m: Total angle ±1
Module A to module B: 36 ±3MHz Module B to module A: 44 ±2.5MHz
FSK
10000 lx or less (avoid direct sunlight)
Wireless transmission using infrared light can be realized.Combination of the AJ65BT-RPI-10A and AJ65BT-RPI-10A allows wireless transmission in the CC-Link system over distances from 1 to 100m using infrared light. By adopting these modules, CC-Link systems can be used in places where wiring is difficult.The maximum transmission speed is 2.5Mbps.
Communication status of modules can be monitored.By setting a station number and parameters on the master station (regarding a pair as a remote I/O station), the optical reception status of connected modules can be monitored (Data are loaded to the master station.)Also, reception status indication with the LEDs is available by sequence programs in the master station, allowing fine adjustment of the optical axis.
AJ65BT-RPI-10A and AJ65BT-RPI-10B must be used as a pair.
Performance specifications
Related manual
Names and settings of each part
5 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
6
B RATE
ST NO.X10
ST NO.X1
C
1
2
3
S
C
1
2
3
R
PW
LRUN
LERR
ERR
SD1
RD1
SD2
RD2
Enlarged view
Enlarged view
FG
DA DB DG SLD
TERMINATEROFF ON
+24V 24G
5 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
6
B RATE
ST NO.X10
ST NO.X1
C
1
2
3
S
C
1
2
3
R
PW
LRUN
LERR
ERR
SD1
RD1
SD2
RD2
FG
DA
DB
DG
SLD
TE
RM
INA
TE
RO
FF
ON
+24
V24
G
LensUsed for optical communication
Operation indicator LEDsThe status of the module can be checked by the on/off status of the LEDs.
Transmission rate setting switchThis is used for setting the transmission rate of the module. (Factory default: 0)
PW
LRUN
LERR
ERR
SD1
SD2
RD1
RD2
SC
S1
S2
S3
RC
R1
R2
R3
LED name Description
ON: Power supply is on.OFF: Power supply is off.ON: Normal communication with the monitoring function usedOFF: Communication error has occurred with the
monitoring function used, or the monitoring function is not used.
ON: Communication error has occurred with the monitoring function used, or the monitoring function is not used.
OFF: Normal communication with the monitoring function usedON: Communication errorOFF: NormalON: Sending data to the cable sideOFF: Not sending data to the cable sideON: Sending data to the optical output sideOFF: Not sending data to the optical output sideON: Receiving data from the cable sideOFF: Not receiving data from the cable sideON: Receiving data from the optical input sideOFF: Not receiving data from the optical input sideON: RY (n+1) 0 is on.OFF: RY (n+1) 0 is off.ON: RY (n+1) 1 is on.OFF: RY (n+1) 1 is off.ON: RY (n+1) 2 is on.OFF: RY (n+1) 2 is off.ON: RY (n+1) 3 is on.OFF: RY (n+1) 3 is off.ON: Optical reception is enabled on this module.OFF: Optical reception is disabled on this module.ON: This module’s light reception level margin is
1.5 times or more.OFF: This module’s light reception level margin is
less than 1.5 times.(Using RC as standard)ON: This module’s light reception level margin is
2.0 times or more.OFF: This module’s light reception level margin is
less than 2.0 times.(Using RC as standard)ON: This module’s light reception level margin is
2.5 times or more.OFF: This module’s light reception level margin is
less than 2.5 times.(Using RC as standard)
Turns on only when the monitoring function is used.
012
3 to 9
156kbps625kbps2.5Mbps
Prohibited
Monitoring function not usedStation number with monitoring function used
Prohibited
Station number setting switch (10s place)
Station number setting switch (1s place)The module’s station number is set. Also, whether to use the monitoring function or not is set. (Factory default: OFF)
0001 to 6465 to 99
POINTThe settings of the transmission rate setting switch and the station number setting switch are made effective when the module is powered ON from OFF. If any setting has been changed with the module power ON, perform the operation again.
Module mounting screwsUsed to fix the module to the mounting metal fittings.
Metal fittingsMetal fittings for mounting the module
Display window mounting screwUsed to fix the display window to the module.Remove the display window when setting the switches.
5 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
65 0
4
9
3
8
2
7
1
6
B RATE
ST NO.X10
ST NO.X1
C
1
2
3
S
C
1
2
3
R
PW
LRUN
LERR
ERR
SD1
RD1
SD2
RD2
Terminal blockThis terminal block is used for connecting the power supply and CC-Link dedicated cables.
Setting value Transmission rate
Terminating resistor switchWhether or not to use the module's built-in terminating resistor (110 ) is set. (Factory default: 0)
129 130
Repeater moduleProduct informationRepeater module
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Unit: mm
System configuration
External dimensions
Module connection
IMPORTANTCC-Link dedicated cables within the same segment must have the same specifications. If not, normal data transmission is not guaranteed.
POINT• Always connect terminating resistors to modules on both segment ends.
A terminating resistor should be connected between DA and DB.(Terminating resistors are supplied with the module.)
• The terminating resistor varies depending on the type of the cable used.For details, refer to the User’s Manual of the master module.
• Connect the shielded wire of the CC-Link dedicated cable to “SLD” of each module. Ground “FG” to the protective ground connector.Note that “SLD” and “FG” are connected inside the module.
The following explains how to connect the AJ65BTRPI-10A/10B to the CC-Link system with the CC-Link dedicated cables.
*1 A repeater is used to make connection between different segments and extend the CC-Link system.AJ65BT-RPI-10A (module A) and AJ65BT-RPI-10B (module B) must be used as a pair.
*2 In the CC-Link system using repeeaters, a block of device connected from one terminal resistor to another is referred to as a segment. (The conventional CC-Link system is made up of one segment.)
*3 It is necessary to match the transmission speed of each segment device to that of the master station (2.5 Mbps/625 kbps/156 kbps).
*4 Up to 2 stages can be added to a system.
[Segment *2]
[Segment (1st stage)]
[Segment (1st stage)]
[Segment (2nd stage) *4]
Remote I/O station
Remote I/O station
Remote I/O station
Remote I/O station Remote I/O station
Local station
Remote devicestation
Remote devicestation
Master station*3
Intelligent device station
Intelligent device station
Repeater*1 (module A/B)
Repeater*1 (module A/B)
Repeater*1 (module A/B)
Repeater*1 (module A/B)
Repeater*1 (module A/B)
Repeater*1 (module A/B) : Terminating resistor (Required)
: Wireless transmission
: CC-Link dedicated cable
Top face Top face Top face
Top face 0 to 100m
1m or more
A shield is required.
Set the modules alternately and 1 m or more apart.
Module A Module B
Module B Module A
1m m
in.
Terminating resistor
Terminating resistor
Terminating resistor
Terminating resistor
Master module Remote module
Local module
AJ65BT-RPI-10A/10B
DA
DB
DG
SLD
FG
DA
DB
DG
FG
SLDCC-Link dedicated cable CC-Link dedicated cable
CC-Link dedicated cable
DA
DB
DG
FG
SLD
DA
DB
DG
FG
SLD
DA
DB
DG
FG
SLD
Wireless transmission
AJ65BT-RPI-10A/10B
Lenssurface
Lenssurface
35.5
57.5
44.0
45.0
130.0
145.0
161.0
40.0
84.0
100.
0
8.0
35.5
12.0 128.0
2.0
5
3 2
0
87
5
3 2
0
87
5
3 2
0
87
B RATE
ST NO.X10
ST NO.X1
C
1
2
3
S
C
1
2
3
R
PW
LRUN
LERR
ERR
SD1
RD1
SD2
RD2
Optical axis adjustment angle ±4° for both left/right and up/down
When mounting the AJ65BT-RPI-10A/10B, mounting orientations are not restricted.However, the module top must face the same direction as the top face of the module with which optical communications will be made. When mounting it in any other orientation, keep a 1m or more distance between the modules.
If multiple pairs of AJ65BT-RPI-10A and -10B are placed in series, provide a shield between pairs. Failure to do so may cause malfunction.
If multiple pairs of AJ65BT-RPI-10A and -10B are placed in parallel, position modules A and B alternately for each pair and keep a 1m distance or more between pairs. Failure to do so may cause malfunction due to interference.
mounting hole (for M6 mounting screw)
42
Three 7 x 16 mounting holes (for M6 mounting screws)
131 132
Repeater moduleProduct informationRepeater module
Rem
ote I/OA
nalogH
igh-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
l
AccessoriesPush-in connector plug
Model name: A6CON-P214 (20PCS)
A6CON-P220 (20PCS)
A6CON-P514 (20PCS)
A6CON-P520 (20PCS)
Push-in connector plug for communication
Model name: A6CON-L5P (10PCS)
Push-in connector plug for power supply and FG
Model name: A6CON-PW5P (10PCS)
A6CON-PW5P-SOD (10PCS)
Protective cap for unused connector
Push-in connector plug with terminating resistor
Model name: A6CON-TR11 (1PC)
Online connector for communication
Model name: A6CON-LJ5P (5PCS)
Online connector for power supply (containing 5PCS)
Model name: A6CON-PWJ5P (5PCS)
Protective cover (for remote I/O module)
Model name: A6CVR-8 (10PCS)
A6CVR-16 (10PCS)
A6CVR-32 (10PCS)
Protective cover (for e-CON type remote I/O module)
Model name: A6CVR-VCE8 (10PCS)
A6CVR-VCE16 (10PCS)
40-pin connector (FCN connector)
Mode namel: A6CAP-DC1 (20PCS)
A6CAP-WP1 (20PCS)
Model name: A6CAP-WP2 (20PCS)
Optional parts
Model: A6CON1 (1PC) < Soldered>name A6CON2 (1PC) <Solderless>
A6CON3 (1PC) <Press-fitting>
A6CON4 (1PC)
Module fixing bracket
Model name: A6PLT1V (5PCS)
A6PLT2V (5PCS)
Product nameProtective cover for 8-point module
(10PCS)Protective cover for 16-point module
(10PCS)Protective cover for 32-point module
(10PCS)
Modelname
A6CVR-8
A6CVR-16
A6CVR-32
W87.3118179
When the protective cover for 8-point module is attachedWhen the protective cover for 16-point module is attachedWhen the protective cover for 32-point module is attached
* The minimum length of the upper part of the protective cover is 10mm or more.
H
62
D
54
A
10.1
Applicable module
W
HA
D
*
40 20 10 8 4 2 1 4 2 1B RATESTATION NO.
ON
AJ65SBTB1-16DT
DA DG +24V 24G
DB SLD (FG)
MITSUBISHI
PW L RUN L ERR X0 1 2 3 4 5 6 7 Y8 9 A B C D E F
YEYCYAY8X6X4X2X0 COM+X7X5X3X1 Y9 9B YD YF COM-
Push-in connector for I/O module communicationsAdopting the press-fitting connection method and providing connectors on the same face will improve wiring works.
Push-in connector for I/O module inputs/outputsAdoption of the press-fitting connection method can drastically reduce wiring steps.
Push-in connector for I/O module power supply and FGAdopting the press-fitting connection method and providing connectors on the same face will improve wiring works.
Push-in connector for I/O module communicationsModule replacement is possible without stopping communication.
Push-in connector with terminating resistor for I/O moduleAdopting the press-fitting connection method and providing connectors on the same face will improve wiring works.
Push-in connector for I/O module power supply and FGModule replacement is possible without stopping communication.
Protective cap for I/O module connector unused.
40-pin (FCN) connector for I/O module
Mounting bracket for I/O or analog modules
AccessoriesM4 x 8 P round-head screws with SW & PW(10 screws)Applicable model (Note)<A6PLT1V>AJ65VBTCU3-8D, AJ65VBTCU2-8T, AJ65VBTCU-68ADVN, AJ65VBTCU-68ADIN, AJ65VBTCU-68DAVN<A6PLT2V>AJ65VBTCU3-16D1, AJ65VBTCU2-16T
Protective cover for e-CON type I/O modulePrevents wiring connector disconnections, and erroneous switch operation.
Protective cover for I/O modulePrevents foreign matter from entering the terminal block.
Applicable model<A6CVR-VCE8 type>AJ65VBTCE3-8D, AJ65VBTCE2-8T type remote I/O modules<A6CVR-VCE16V type>AJ65VBTCE3-16D, AJ65VBTCE2-16T type remote I/O modules
List of models
External dimensions
External dimensions
Applicable modelAJ65VBTS - type remote I/O modulesAJ65BTCF - type remote I/O modulesAJ65VBTCF - type remote I/O modules
Applicable modelAJ65SBTW - type remote I/O modules
Applicable modelAJ65FBTA - type remote I/O modules
AJ65SBTB1-8 , AJ65SBT-RPT
AJ65SBTB1-16 , AJ65SBTC1-32 , AJ65SBT-RPG, AJ65SBT-RPS, AJ65SBTC4- , AJ65SBTB2N-8 , AJ65SBTB2-8 , AJ65SBTB3-8D, AJ65SBTB32-8DTAJ65SBTB1-32 , AJ65SBTB2-32 , AJ65SBTB2N-16 , AJ65SBTB3-16 , AJ65SBTB32-16DT
< Soldered (for straight slant type only) >
Unit: mm
Unit: mm
103.5 86.5
89
Module installation dimension
86.5104
A6CVR-VCE8
A6CVR-VCE16
54
39
29
43.5
2929
907
7
Module installation dimension
Model name
A6CON-PW5PA6CON-PW5P-SOD
Applicable cablecore (mm2)
0.75(0.66 to 0.98)(AWG#18)
Model name
A6CON-P214A6CON-P220A6CON-P514A6CON-P520
Applicable cablecore (mm2)0.14 to 0.2
(AWG#26 to 24)0.3 to 0.5
(AWG#22 to 20)
Applicable modelAJ65SBTC - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modules
Applicable modelAJ65VBTS - type remote I/O modulesAJ65VBTCE - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modulesAJ65SBT-CLBM-M type CC-Link-CC-Link/LT bridge modules
Applicable modelAJ65VBTS - type remote I/O modulesAJ65VBTCE - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modulesAJ65SBT-CLBM-M type CC-Link-CC-Link/LT bridge modules
Applicable modelAJ65VBTS - type remote I/O modulesAJ65VBTCE - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modulesAJ65SBT-CLBM-M type CC-Link-CC-Link/LT bridge modules
Applicable modelAJ65VBTS - type remote I/O modulesAJ65VBTCE - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modulesAJ65SBT-CLBM-M type CC-Link-CC-Link/LT bridge modules
Applicable modelAJ65VBTS - type remote I/O modulesAJ65VBTCE - type remote I/O modulesAJ65VBTCU - type remote I/O modulesAJ65VBTCU- type analog modulesAJ65SBT-CLBM-M type CC-Link-CC-Link/LT bridge modules
Applicable cableoutside diameter (mm)
1.0 to 1.4 1.4 to 2.0 1.0 to 1.4 1.4 to 2.0
Applicable cableoutside diameter (mm)
2.2 to 3.0 2.0 to 2.3
*For details of open sensor connectors (e-CON), refer to page 187.
133 134
Optional partsProduct information
Rem
ote
I/OA
nalo
gH
igh-
spee
dco
unte
rP
ositi
onin
gPe
riphe
ral d
evice
conn
ectio
nR
S-2
32 I/
FP
C in
terf
ace
Rep
eate
rO
ptio
nO
ther
/S
oftw
are
Em
bedd
edT
echn
ical
Info
rmat
ion
Sup
port
Mas
ter/
Loca
lR
emote I/O
Analog
High-speedcounter
Positioning
Peripheral deviceconnection
RS
-232 I/FP
C interface
Repeater
Option
Other/
Softw
areE
mbedded
Technical
Information
Support
Master/Local
135
MemoMemoMemo
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
r
Product Information141
147
149
179
183
187
137
139
Master modules/Bridge module
Bridge module
Remote I/O modules
Analog modules
Dedicated power supply/Power supply adapter
Optional parts
System Configuration ExamplesUsing dedicated flat cables only
Using various cables
Em
bedd
ed
136
Screw terminal block type analog modules
P.179Cable type remote I/O modules
P.175
Dedicated power supply
CL2XY16-DTP1C5V
IN
Y
0
1
2
3
4
5
6
7
OUT
ST.No.
1 2 3 4 5 6 7 8 9ONLINK/PW
Screw terminal block type remote I/O modules
P.153
P.171P.165
CC-Link/LT master modules
CC-Link-CC-Link/LTBridge module MIL connector type
remote I/O modules
* Install the master module at one end of the trunk line.
* Use identical terminating resistors at both ends. Place it close to the master module (within 20cm).
Manufactured by Mitsubishi Electric Engineering Co., Ltd.
Handy line tester
Terminatingresistor
Terminatingresistor
P.147
P.187
P.183
P.183
P.187
Dedicated flatcable
Connector for dedicated flat cable connection
Separation and extensionusing connectors
* When separating or extending a trunk line, up to 10 connections are available using connectors.
P.187Open sensor
connector
P.187
Sensor connector type remote I/O modules
Spring clamp terminal block type remote I/O modules
P.159
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
FX2N-64CL-M CC-Link/LT PLCwith master function FX3UC-32MT-LT
QJ61CL12
AJ65SBT-CLB
CL1PSU-2A
CL9-CNF-18 CL9-FL4-18
EHLT01
CL9-TERM
CL1PAD1POWER
+24V
24G
DBDA
24GDBDA
+24V
LCNET/POWER
LINK
CL2Y8-TP1B2
Y0Y1Y2Y3
Y4Y5Y6Y7
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO.0.5ms1.5ms
ON
OUT
0 1 2 3 4 5 6 7
IN
X0X1X2X3
0 1 2 3
PW L RUN L ERR.
STATION NO.
ON
Y3Y2Y1Y0DC24V
COM+COM+
COM+COM+
DC24V
40 20 10 8 4 2 1STATION NO. HLD
ON
0 1 2 3
PW L RUN. L ERR.
LINK/PW
OUTCL1Y4-T1S2
Spring clamp typecommon terminal block
P.188
CL1PSU-2A
24V
DBDA
24GDBDA
+24V
LCNET/POWER
LINKACBS-2SW L N
24VDC
General-purpose power supply
FX2N-32MR
0 1 2 3 4 5 6 710 11 12 13 14 15 16 17
IN
0 1 2 3 4 5 6 710 11 12 13 14 15 16 17
IN
POWERRUNBATT.VPROG.ECPU.E
PULL
USB
PULL
Q25HCPU
MODERUNERR
USERBAT
BOOT
RS-232
POWER
Q61P-A1
QJ71C24 QJ61BT11
QX10QJ61CL12
QJ71LP21-25
SW ON
12345678
NPO
B RATE
MODE
TEST
PW
L RUN
L ERR.
0123456789ABCDEF
CL2X16-D1M1V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
PW
L RUN
L ERR.
0123456789ABCDEF
CL2Y16-TP1M1V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
OUT
ON
Power supply adaptor (for expansion)
FX2N-64CL-M
RUNERR.
L RUNL ERR.
SDRD
POWER
AJ65SBT-CLB
40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1
PW L RUN L ERR.
STATION NO. B RATE NOS TST MODE B RATE NC
ON
CC-Link
CC-Link/LT
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8
CC-Link
L RUN L ERR. L ERR.
CC-Link/LTCC-Link
CC-Link/LT
P.141
FX3UC-32MT-LT
* Can be used with any of dedicated flat cable, VCTF cable and flexible cable.
137 138
CL2X8-D1C3V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
System Configuration ExamplesUsing dedicated flat cables only
CL1X2-D1D3S
PW L RUN 0
STATION NO.
402010 8 4 2 1HLD
COMM.
1
24G X0 Y0 +24VIN OUT
Module holder P.188
CL1Y2-T1D2S
PW L RUN 0
STATION NO.
402010 8 4 2 1HLD
COMM.
1
24G X0 Y0 +24VIN OUT
Screw terminal block typecommon terminal block
P.188Screw terminal block type
common terminal blockP.188
CH1
CH2
CH3
CH4
0~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFF
OFFOFFOFFOFFOFF
0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW
L ERR.RUN
9 107 85 63 4
4 5 6 7 8 9 1 2
1 2 310
ON
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.
0 1 2NC
CH1
CH2
0~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFF
OFFOFFOFFOFFOFF
0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW
L ERR.RUN
9 107 85 63 4
4 5 6 7 8 9 1 2
1 2 310
ON
CL2AD2-B
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.
0 1 2NC
Power supply adapter
CL2TE-10SCL2TE-5
CL9-TERM
ECN-******
CL1PAD1
CL1-HLD
CL2TE-5
PW
L RUN
L ERR.
0123456789ABCDEF
CL2X16-D1M1V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
CL1PSU-2A
24V
DBDA
24GDBDA
+24V
LCNET/POWER
LINKACBS-2SW L N
IN
X0X1X2X3
0 1 2 3
PW L RUN L ERR.
STATION NO.
ON
Branch line: dedicated flat
CL2X8-D1C3V
ST.No.
1 2 3 4 5 6 7 8
LINK/PW
IN
ON
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL1PSU-2A
24V
DBDA
24GDBDA
+24V
LCNET/POWER
LINKACBS-2SW L N
PULL
USB
PULL
Q25HCPU
MODERUNERR
USERBAT
BOOT
RS-232
POWER
Q61P-A1
QJ71C24 QJ61BT11
QX10QJ61CL12
QJ71LP21-25
SW ON
12345678
NPO
B RATE
MODE
TEST
Flexible cable connector
CC-Link/LT master module
Body: Light blueCover: Green
Body: Light blueCover: Yellowish green
VCTF cable connector
Dedicated flat cable connector
Power supply adaptor (for expansion) Terminating resistor
Flexible cable
P.187P.187 P.187
Dedicated flat cable
P.187
VCTF cable
P.187
* Can be used with any of dedicated flat cable, VCTF cable and flexible cable.
* Use a commercially- available terminal block.
* Use identical terminating resistors at both ends. Place it close to the master module (within 20cm).
* Use cables approved by the CC-Link Partner Association.
T-branching using connector
T-branching using terminal blockT-branching using connector
Branch line: dedicated flat
Trunk line: VCTF
Branch line: VCTF
Trunk line: VCTF
Branch line: VCTF
Branch line: flexible
139 140
CL1X2-D1D3S
PW L RUN 0
STATION NO.
402010 8 4 2 1HLD
COMM.
1
24G X0 Y0 +24VIN OUT
CL1Y2-T1D2S
PW L RUN 0
STATION NO.
402010 8 4 2 1HLD
COMM.
1
24G X0 Y0 +24VIN OUT
Terminatingresistor
PULL
USB
PULL
RS-232
SW ON
12345678
NPO
B RATE
MODE
TEST
Body: Light blueCover: Light blue
Using various cables
QJ61CL12
CL1PSU-2A
CL9-TERM
CL1PSU-2A
CL9-CNR-23 CL9-CNR-20CL9-CNF-18
CL9-FL4-18
CL9-TERM
141 142
Master modules/Bridge moduleProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Using the point mode
Master and bridge modules supporting MELSEC CPUs are available.
For Q seriesQJ61CL12
Model names
Product name
Q series master module
FX3UC PLC (built-in master function)
FX Series master module
CC-Link - CC-Link/LT
bridge module
QJ61CL12
FX3UC-32MT-LT
FX2N-64CL-M
AJ65SBT-CLB
Model
QJ61CL12 type CC-Link/LT Master Module User's Manual
FX3UC Series User's Manual (Hardware)
FX2N-64CL-M type CC-Link/LT Master Module User's Manual
AJ65SBT-CLB type CC-Link - CC-Link/LT Bridge Module User's Manual
Related manual
For FX seriesFX2N-64CL-M
4-point mode
8-point mode
16-point mode
2- or 4-point module
1 station occupied
1 station occupied
1 station occupied
8-point module
2 stations occupied
1 station occupied
1 station occupied
16-point module
4 stations occupied
2 stations occupied
1 station occupied
Q master
FX master
FX master
Q master FX master
Q master FX master
For FX seriesFX3UC-32MT-LT
For CC-LinkAJ65SBT-CLBBridge
Bridge
Bridge
Master modules/Bridge module
Overview
P.144 P.145
P.146 P.147
<Overview>
A new "point number mode" has been adopted to promote efficient handling of CC-Link/LT input/output points.
The "point number mode" comprises a 4-point mode, an 8-point mode, and a 16-point mode, allowing the number of controlled remote stations to be changed by a "point number mode" setting, even when the "number of occupied I/O points" setting is the same. (The FX series master module has only 2 modes: a 4-point mode, and a
16-point mode.)
The "point number mode" allows the occupied station number to be changed even though the remote I/O module is the same.
Unit: mm
Part Names and Settings
QJ61CL12 Master module (For Q series)Point mode setting examples
For
ForQ master Bridge
FX master
Q master
External dimensions
QJ61CL12
Operation setting switch setting details
LED indicationLED name Description
RUN
ERR.
L RUN
L ERR.
SD
RD
On: Module is operating normally
On: Switch setting error
Flicker: Switch moved during operation
On: Data link in execution
On: Data link error station (detected), any station outside control range
Flicker: Data link error stations (all stations)
On: Data being sent
On: Data being received
LED
Operationsetting switches
CC-Link/LTinterface connector
LINK
ON
TEST
MODE
B RATE
87654321
SW
POINTSI/O
16 points 32 points 48 points 64 points 128 points 256 points 512 points 1024 points
1
2
3
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF ON
OFF
OFF ON
OFF
ON
OFF
ON
ON ON
ON
ONI/O POINTS
Transmissionspeed setting
4
5
*ERR. LED is lit if the switches are moved to the position that must not be set.
MODE6
7
625Kbps
OFF
ON
4 points
OFF
ON
2.5Mbps
OFF
ON
16 points
OFF
ON
Must not be set *
*
ON
ON
Must not be set
ON
ON
Number of occupied I/O points
B RATE
Point mode setting
TEST8
Test mode
156Kbps
OFF
OFF
8 points
OFF
OFF
OFF: ON LINE (normal operation)
Pin No.
4
3
2
1
Signal Name
24G
DB
DA
+24V
Ope
ratio
n se
tting
sw
itche
s
ON: TEST mode (loopback test)
RUN
ERR. L ERR.RDSDL RUN
27.4
QJ61CL21
LINK
QJ61CL21
TEST
MODE
B RATE
87654321
SW
90
98
POINTSI/O
X /Y 0
X /Y 10
X /Y 20
X /Y 30
1) 4 points
2) 8 points
3) 4 points
4) 2 points
5) 16 points
6) 4 points
7) 4 points
Vacant: 4 points
Vacant: 4 points
Vacant: 6 points
Vacant: 4 points
Vacant: 4 points
Total No. of stations: 8
No. of occupied I/O points: 64
1 station
2 stations
1 station
1 station
1 station
1 station
1 station
X /Y 0
X /Y 10
X /Y 20
1) 4 points
2) 8 points
3) 4 points4) 2 points
5) 16 points
6) 4 points
7) 4 points
1 station
2 stations
1 station
1 station
4 stations
1 station
1 station
1 station
Vacant: 2) points
Vacant: 4 points
No. of occupied I/O points: 48Total No. of stations: 12
X /Y 0
X /Y 10
X /Y 20
X /Y 30
X /Y 40
X /Y 50
X /Y 60
X /Y70
1) 4 points
2) 8 points
3) 4 points
4) 2 points
5) 16 points
6) 4 points
7) 4 points
Vacant: 12 points
Vacant: 8 points
Vacant: 12 points
Vacant: 14 points
Vacant: 12 points
Vacant: 12 points
Vacant: 16 points
Total No. of stations: 8
No. of occupied I/O points: 128
1 station
1 station
1 station
1 station
1 station
1 station
1 station
1 station
System configuration example2-point module: 1 4-point module: 48-point module: 1 16-point module: 1
In this example, the 4-point mode is the most effective "number of occupied points" setting. It is advisable to select the point mode corresponding to the I/O points of the remote I/O modules which quantity is the largest in the system.
8-point mode (8 points/station)4-point mode (4 points/station) 16-point mode (16 points/station)
Station 1)Input
4 points
Station 2)Output8 points
Station 3)Output4 points
Station 5)Input
16 points
Station 6)Input
4 points
Station 7)Output4 points
Station 4)Comon2 points
FX2N-32M
As a whole system, the FX series canbe used within the following ranges.FX1N, FX1NC ≤ 128 pointsFX2N, FX2NC ≤ 256 points
1)
2)
3)
4)
5)
6)
7)
Empty
The remote I/O modules 1) to 7) are assigned consecutive I/O numbers in units of 8 points.When an extension module/block is connected after the master module in this example, it is assigned the I/O numbers of X60 and later/Y50 and later.
I/O Numbers (In the case of FX2N-32M)
FX2N-32MFX2N-
64CL-M
1 station
2 stations
1 station
1 station
4 stations
1 station
1 station
1 station
1 station
1 station
1 station
1 station
1 station
1 station
Input: X
X0 to X17
X20 to X23
X24
X25 to X44
X45 to X50
X51 to X57
Output: Y
Y0 to Y17
Y20 to Y27
Y30 to Y33
Y34
Y35 to Y40
Y41 to Y47
Rem
ote
I/O m
odul
e
The I/O numbers of the remote I/O modules connected to the FX series master module are continued from the preceding ones to eliminate unassigned numbers.(However, as the I/O numbers of the FX series are assigned in units of 8 points, there will be a maximum of 14 (7/7) unassigned numbers if 8 points are not occupied by the last module.)
For the FX series master module, the number of occupied points does not change if the setting is either the 4- or 16-point mode. (64 stations can be connected.)
4-points modeTotal number ofstations : 11 stations
16-points modeTotal number ofstations : 7 stations
Number of stations that can be connected for each setting of master module
Number of stations that can be connected for each setting of bridge
<Example>When the number of occupied I/O points is 256, the master module can connect:4-point mode: Up to 64 stations8-point mode: Up to 32 stations16-point mode: Up to 16 stations
Number of maximumCC-Link/LT connected stations
4-point mode
8-point mode
16-point mode
2 Stations Occupied
12
6
3
4 Stations Occupied
28
14
7
8 Stations Occupied
56
28
14
Number of Master Module'sOccupied I/O Points
16Points
32Points
48Points
64Points
128Points
256Points
512Points
1024Points
4-point mode
8-point mode
16-point mode
4
2
1
8
4
2
12
6
3
16
8
4
32
16
8
64
32
16
-
64
32
-
-
64
Pointmodesetting
Number of CC-Link OccupiedI/O Stations
Q master
Bridge
QCPU
QJ61CL12
Station 1)Input
4 points
Station 2)Output8 points
Station 3)Output4 points
Station 5)Input
16 points
Station 6)Input
4 points
Station 7)Output4 points
Station 4)Comon2 points
Powersupply
Input/output
Current consumption: 130mA (5VDC, power supplied from PLC),
28mA (24VDC, power supplied from power supply adaptor)
Starting current : 70mA (24VDC, power supplied from power supply adaptor)
Weight : 0.09kg
QCPU High Performance model
QCPU Basic model
Process CPU
NET/H remote station
PC CPU *3
Connectable CPU Models Number of Mountable Modules
Max. 64
modules
Q02CPU,Q02HCPU,Q06HCPU,Q12HCPU,Q25HCPU
Q00JCPU*2,Q00CPU,Q01CPU
Q12PHCPU,Q25PHCPU
QJ72LP25-25,QJ72LP25G(E),QJ72BR15
PPC-CPU686(MS)-64, PPC-CPU686(MS)-128
*1:The number of usable master modules changes depending on the occupied I/O point setting of the master module.
*2:Having a maximum of 256 I/O points, the Q00JCPU can use only the I/O points within the 256-point range.(When the occupied I/O point setting is more than 256 points, the Q00JCPU detects an error and does not operate.)
*3:The PC CPU is made by CONTEC CO., LTD.
*1
Applicable CPU
ON
143 144
Master modules/Bridge moduleMaster modules/Bridge moduleProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Part Names and Settings FX2N-64CL-M(With top cover open)
FX2N-64CL-M Master module (FX series)
LED indication
FX1N, FX1NC
FX2N, FX2NC, FX3UC
Connectable CPU models Number of I/O points used
Base unit + extension unit/block + special module (8 occupied points) x No. of modules used + occupied points for CC-Link/LT <= 128 points
Base unit + extension unit/block + special module (8 occupied points) x no. of modules used + occupied points for CC-Link/LT <= 256 points
Actual size
* Because the FX2N-64CL-M is handled as a special module, it occupies 8 I/O points (inputs or outputs). (This does not include the no. of points occupied by CC-Link/LT.)
The FX2NC-CNV-IF is required in order to connect with the FX1NC, FX2NC, FX3UC.
Unit: mm
LED name DescriptionPOWER
RUN
ERR.
L RUN
L ERR.
SD
RD
ON: Module power is supplied (excluding communication power).
OFF: No module power is supplied (excluding communication power).
ON: Module is operating normally.
ON: Switch setting error
Flashing: Switch changed during operation
ON: Data link in execution
ON: Data link error station (detected), a station out of control range exists.
Flashing: Data link error stations (all stations)
ON: Sending data
ON: Receiving data
Part Names and Settings
FX3UC-32MT-LT Micro PLC (Built-in master function)
FX3UC
CPU models Number of I/O points used
Base unit + extension unit/block + special module (8 occupied points) x No. of modules used + occupied points for CC-Link/LT <= 256 points
Unit: mm
LED indicationLED name DescriptionPOW
RUN
ERR.
L RUN
L ERR.
SDRD
ON: PLC power suppliedOFF: PLC power not suppliedON: PLC runningOFF: PLC stoppedON: Low battery voltageOFF: Normal battery voltageFlashing: Program error has occurred.ON: CPU error has occurred.ON: Data link in execution (CC-Link/LT network)OFF: Data link stopped (CC-Link/LT network)ON: Data link error (CC-Link/LT network)Flashing: Data link error has occurred on all stations (CC-Link/LT network)OFF: Data link is normally operated.
FX3UC-32MT-LT(With display module removed)
Actual size
Operation setting switch detailsTransmission rate setting
1
2
* The “ERR.” LED will light up if the switches are set to the prohibited positions.
MODE3
625Kbps
OFF
ON
16 points
ON
2.5Mbps
OFF
ON
Setting prohibited *
ON
ONB RATE
Point mode setting
TEST7
Test mode
156Kbps
OFF
OFF
4 points
OFF
CONFIG6
CONFIG mode OFF: ON LINE (normal operation)ON: CONFIG mode (checks connected stations and saves that information to the internal EEPROM.)
OFF: ON LINE (normal operation)ON: TEST mode (loop-back test)
4
5
Unused
Unused
Unused
Unused8
12
34
56
78
OFFON
B RATE
16pts. 4pts.
ONLINE
-
TEST
-
3
2
1
4
5
6
7
8
- -
CONFIG ONLINE
FX2N-64CL-M
- -
O N
LINK
Operation setting switch detailsTransmission rate setting
1
2
* The “ERR.” LED will light up if the switches are set to the prohibited positions.
MODE3
625Kbps
OFF
ON
ON
2.5Mbps
OFF
ON
Setting prohibited *
ON
ONB RATE
Point mode setting
TEST7
Test mode
156Kbps
OFF
OFF
4 points 16 points
OFF
CONFIG6
CONFIG mode OFF: ON LINE (normal operation)ON: CONFIG mode (checks connected stations and saves that information to the internal EEPROM.)
OFF: ON LINE (normal operation)ON: TEST mode (loop-back test)
4
5
Unused
Unused
Unused
Unused8
FX master FX master
Ope
ratio
n se
tting
sw
itch
Ope
ratio
n se
tting
sw
itch
FX2N-64CL-M
FX2N
-64C
L-M
RUN
ERR.
L RUN
L ERR.
SD
RD
POWER
43
4
87
90
80±0
.5 (
Mou
ntin
g di
men
sion
s)
90
55
83
87
13 74
: 7W
: Max. 30mA 0.5 ms/24VDC
: 24VDC 350mA (for CC-Link/LT network)
: 0.25kg
: 190mA (5VDC, supplied from PLC)
25mA (24VDC, supplied from power adapter)
: 35mA (24VDC, supplied from power adapter)
: 0.15kg
Current consumption
Inrush current
Built-in power supply
Weight
External dimensions External dimensions
Current consumption
Current at start-up
Weight
Applicable CPUApplicable CPU
145 146
Master modules/Bridge moduleMaster modules/Bridge moduleProduct Information
No power supply adapter is needed up to 350mA as a power supply is built in.
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Names and settings of each part
AJ65SBT-CLB Bridge module (For CC-Link)
Unit: mm
Operation setting switch details
Description
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.
8 points
4 points
16 points
2
OFF
OFF
ON
1
OFF
ON
OFF
Settings other than the above cause a setting error. ("L ERR." turns ON)
156kbps
625kbps
2.5Mbps
2
OFF
OFF
ON
1
OFF
ON
OFF
Settings other than the above cause a setting error. ("L ERR." turns ON)
LED indication
Common
CC-Link part
CC-Link/LTpart
Red
Tens digitStationNo. 40
OFF
OFF
OFF
OFF
OFF
OFF
ON
20
OFF
OFF
OFF
OFF
OFF
OFF
ON
10
OFF
OFF
OFF
OFF
ON
ON
OFF
Units digit
Setting value
Setting value
Setting value
Setting value
Setting switch
Setting switch
Setting switch
Setting switch
Occupied Stations
Points mode
Transmissionrate
Transmission rate
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
OFF
ON
OFF
OFF
OFF
2
OFF
ON
ON
OFF
OFF
OFF
ON
1
ON
OFF
ON
OFF
OFF
ON
ON
0 (Factory default)
1
2
3
4
0 (Factory default)
1
2
0 (Factory default)
1
2
0 (Factory default)
1
2
2
OFF
OFF
ON
ON
OFF
4
OFF
OFF
OFF
OFF
ON
1
OFF
ON
OFF
ON
OFF
2
OFF
OFF
ON
1
OFF
ON
OFF
156kbps
625kbps
2.5Mbps
5.0Mbps
10Mbps
Settings other than the above cause a setting error. ("L ERR." turns ON)
Settings other than the above cause a setting error. ("L ERR." turns ON)
2 stations
4 stations
8 stations
Station no. setting switchSTATION NO.
Transmission rate setting switchB RATE
Occupied stations setting switchNOS: Numbers of Occupied Stations
Self-loopback test setting switch TEST
Point mode setting switchMODE
Transmission rate setting switchB RATE
CC
-Lin
k/LT
CC
-Lin
k
OFF: Regular operation mode (factory default)ON: Self-loopback test mode
PW
L RUN
L ERR.
L RUN
L ERR.
ERR.
NameDescriptionLED name ColorON: The module is normaliy operating.OFF: Module error or no power supply.ON: Data link communication is normal.OFF: Data link communication failure (timeout)ON: CC-Link switch setting error
Data link communication errorFlashing: CC-Link switch changed during operationOFF: Normal
<During regular operation>ON: Data link in executionOFF: Data link stopped<Self-loopback test mode>ON: Self-loopback test normalOFF: Self-loopback test fault
<During regular operation>ON: Data link error station (detected), a station out of control range exists.Flashing: Data link error stations (all stations)OFF: No error<Self-loopback test mode>ON: Self-loopback test faultOFF Self-loopback test normal
Setting error detectionON: LT side switch setting errorFlashing: LT side switch changed during operationOFF: No error
Actual size
All are set to OFF prior to shipment.When 2, 4 or 8 stations are occupied, numbers ranging 1 to 63, 61 or 57 can be set respectively. Any other number setting causes a setting error. (“L ERR.” turns on.)
1
2
3
4
10
11
63
Push-in communicationconnector plug
Push-in connector plug with terminating resistor
CC-Link wiring connectors for the AJ65SBT-CLB bridge module.
Online communication connector
Bridge module accessories
Bridge
Q series
QnA series
A series
FX series
PCI board
Other
Connectable master models
QJ61BT11, QJ61BT11N
AJ61QBT11, A1SJ61QBT11
AJ61BT11, A1SJ61BT11
FX2N-16CCL-M*
A80BD-J61BT11, Q80BD-J61BT11N
CC-Link partner manufacturers’ master modules
Model name
Max. No. of connectable stations (CC-Link/LT)
4-point mode
8-point mode
16-point mode
No. of occupiedstations
No. of occupied stations (CC-Link)
AJ65SBT-CLB
CC-Link/LT
CC-Link
2 stations
12 stations
6 stations
3 stations
4 stations
28 stations
14 stations
7 stations
8 stations
56 stations
28 stations
14 stations
1 to 56
Connected at end of trunk line
Remote station no.
Bridge station position
Remote device station
Selected from 2, 4 and 8 stations
When 2 stations is selected: RX/RY: 64 points each (including 16 for system use), RWr/RWw: 8 words each
When 4 stations is selected: RX/RY: 128 points each (including 16 for system use), RWr/RWw: 16 words each
When 8 stations is selected: RX/RY: 256 points each (including 32 for system use), RWr/RWw: 32 words each
Station type
* When 8 stations are occupied, make a parameter setting so that two consecutive 4-station-occupying modules are connected.
: 75mA (24VDC, supplied from power adapter)
: 165mA (24VDC, supplied from power adapter)
: 0.09kg
External dimensions
Applicable master module
Bridge module configuration example
Performance specifications
Current consumption
Current at start-up
Weight
* The FX series can be used in a system within the following range:FX1N, FX1NC 128 pointsFX2N, FX2NC 256 points
LED Operation setting switches
CC-Linkinterface connector
CC-Link/LTinterface connector
AJ65SBT-CLB
(FG)
ON
8
ERR. LERR.RUNLLRUN ERR.PW L RATE RATE NCBNOSBSTATION NO. TST112121241248102040
MODE
4 5 6 7 8 9 1 2 4 526 71 2 3 10 3
CC-Link/LTCC-Link CC-Link CC-Link/LT
CC-Link/LTCC-Link
AJ65SBT-CLB
(FG)
ON
9
ERR. L ERR.RUNLLRUN ERR.PW L RATE RATE NCBNOSBSTATION NO. TST112121241248102040
MODE
4 5 6 7 8 9 1 2 4 526 71 2 3 10 3
CC-Link/LTCC-Link CC-Link CC-Link/LT
CC-Link/LTCC-Link
DIN rail center
22
(4.5)
87 40
10
(4)
(4)
4.5
49
78 0.4
41
0.2
2- 4.5 5.1 mounting hole(M4 mounting screw)
CL1PSU-2A
24V
DBDA
24GDBDA
+24V
LCNET/POWER
LINKACBS-2SW L N
CL1PSU-2A
Product name Model name Specification
Push-in communicationconnector plug (10 PCS)
Online communicationconnector (5 PCS)
Push-in connector plug with terminating resistor (1 PC)
A6CON-L5P
A6CON-LJ5P
A6CON-TR11
Bridge module
CC-Link master module
Push-in connector plug for communication: 5 pins [transmission circuit terminal (press-fitting type)]Applicable cable: FANC-110SBH (Kuramo Electric Co., Ltd.) CS-110 (Daiden Co., Ltd.)
Online connector for communication: 5 pairs (10 pins)
Push-in connector plug for communication with terminating resistor (110 )* Make sure to use this terminating resistor if a
connector type I/O module is used at the terminal station.
147 148
Master modules/Bridge moduleMaster modules/Bridge moduleProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Overview
A variety of modules have been produced for supporting many kinds of external connection devices and applications.
Suitable for the general type connection, solderless terminal connection. No retightening needed.
Easy sensor connection
Direct wiring to sensors, etc.
Wiring is easy and it is convenient when a connecting device is located nearby.
Screw T. block
Sensor
How to read the model name
Cable
CL1 2 3 4 5 6
Connection formatB: Screw terminal blockS: Spring clamp terminal blockC: Sensor connectorM: MIL connectorD: Cable type
5
6
7
Wire type1: Single wire type2: 2-wire type3: 2- or 3-wire type5: 2- or 3-wire type for inputs,
2-wire type for outputs
ShapeS: Ultra-compact typeV: Vertical type
None: Standard type (horizontal type)
7Module for CC-Link/LT
Total number of I/O points
Module type
: 1 or 2
X: InputY: Output
XY: I/O composite
1
2
2: 2 points4: 4 points8: 8 points
16: 16 points
I/O specificationsD1: 24VDC inputR1: Relay output 2AT1: Transistor output 0.1A
TP1: Transistor output 0.1A (with output protection function)
DT1: 24VDC input/transistor output 0.1ADR1: 24VDC input/relay output 2A
DTP1: 24VDC input/transistor output (with output protection function)
3
4
MIL
P.159
P.171
P.153
P.165
Screw terminal block type Spring clamp terminal block type
Sensor connector type (e-CON)
Cable type
MIL connector type
Common Terminal Block
Convenient!
Spring clamp
Screw terminal block
CL2TE-5 Compatible models: CL2X8-D1B2, CL2Y8-TP1B2
When using an input module
Spring clamp terminal block
CL2TE-10S Compatible models: CL2X8-D1S2
Usable as 1 point / common.
When using an output module
Usable as 1 point / common. By connecting a +24V wire to the common terminal block, connection of a 3-wire sensor is available.
When using an input moduleBy connecting a +24V wire to the common terminal block, connection of a 3-wire sensor is available.
CL2Y8-TP1B2
Y0Y1Y2Y3
Y4Y5Y6Y7
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO.0.5ms1.5ms
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
Included: 1 daisy chain cable with solderless terminal (100mm)
P.175External connection (wiring example)
External connection (wiring example)
X0COM BX1X2COM BX3X4COM BX5X6COM B
Pin No.12345678910
CL2TE-10S
Connected I/O moduleReference (CL2X8-D1S2)
Signal codeCOMCOMCOMCOMCOMCOMCOMCOMCOMCOM
X7
DC24VDC24V
DC24VExternal wiring
12345
891011121314
67
1
2
3
4
5
CL2TE-5
Included: 1 daisy chain cable with solderless terminal(between CL2TE-5 and I/O module)
I/O module
2-wire sensor(Sink output)
(NPN output type)
3-wire sensor(Sink output)
(NPN output type)
- +COM
COM
COM
COM
COM
Detectioncircuit
Detectioncircuit
DC24VExternal wiring
Crossover wiring between CL2TE-10S and I/O module
I/O module
3-wire sensor(Sink output)
(NPN output type)
CL2TE-10S
- +
DC24ADC24BX0COM BX1COM BX2COM BX3COM B
COM B
DC24ADC24B
12345
89
1011121314
67
1
2
3
4
5
COM
COM
COM
COM
COM
6
7
8
9
10
COM
COM
COM
COM
COM
X515COM B16X617COM B18
19COM B20
X4
X7
Pin No.12345
CL2TE-5
Connected I/O moduleReference (CL2X8-D1B2)
Signal codeCOMCOMCOMCOMCOM
Detectioncircuit
Detectioncircuit
149 150
Remote I/O modulesRemote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Protection
Protection
Protection
CL1X2-D1D3S
CL1X4-D1B2
CL1X4-D1S2
CL1X4-D1C3
CL2X8-D1B2
CL2X8-D1C3V
CL2X8-D1S2
CL2X16-D1M1V
CL2X16-D1C3V
CL1Y2-T1D2S
CL1Y4-T1B2
CL1Y4-R1B2
CL1Y4-R1B1
CL1Y4-T1S2
CL1Y4-T1C2
CL2Y8-TP1B2
CL2Y8-TP1C2V
CL2Y8-TP1S2
CL2Y8-TPE1S2
CL2Y16-TP1M1V
CL2Y16-TPE1M1V
CL2Y16-TP1C2V
CL1XY2-DT1D5S
CL1XY4-DT1B2
CL1XY4-DR1B2
CL1XY8-DT1B2
CL1XY8-DR1B2
CL2XY16-DTP1C5V
175
154
161
167
154
167
161
172
168
176
155
155
156
162
168
156
169
162
163
172
173
169
176
157
157
158
158
170
Features
Prod
uct
nam
e
Input Output Type OthersPage
Transistoroutput
pts2Transistor
output
pts4
Transistoroutput
pts4
Transistoroutput
pts8Transistor
output
pts8
Transistoroutput
pt1
Transistoroutput
pts8
Transistoroutput
pts2
Transistoroutput
pts4
Transistoroutput
pts8
Transistoroutput
pts16
Transistoroutput
pts16
DC input
pts2
DC input
pts2
DC input
pts4DC input
pts4DC input
pts4DC input
pts8DC input
pts8DC input
pts8
2
DC input
pt1
DC input
pts4DC input
pts4DC input
pts8
-wire2
-wire2pts4Relayoutput
pts4Relayoutput
pts4Relayoutput
0.1A
-wire20.1A
-wire20.1A
-wire20.1A
-wire20.1A
-wire20.1A
-wire20.1A
2A
-wire20.1A
-wire2
-wire20.1A
2A
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Screw T. block
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
MIL
MIL
Model list
Model
DC input
pts16DC input
pts16
-wire20.1A
-wire10.1A
-wire20.1A
-wire20.1A
-wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire124VDC
Cable
Cable
Cable
or
or
-wire324VDC
-wire324VDC
-wire324VDC
-wire324VDC
-wire324VDC
-wire324VDC
or
or
or
or
Hold
Hold
Hold
Hold
Hold
Hold
Hold
Hold
Hold
Hold
ProtectionTransistoroutput
pts16MIL
-wire10.1A Hold
Hold
Hold
Hold
Hold
Hold
Hold
-wire12A
Protection
VerticalProtection
Hold VerticalProtection
DC input
pts2 -wire22A
Spring clamp
Transistoroutput
pts8 -wire20.1A HoldProtectionSpring clamp
Spring clamp
Spring clamp
Spring clamp
pts4Relayoutput
pts2Relayoutput
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
2 -wire224VDC
Inpu
t mod
ule
Out
put m
odul
eC
ombi
ned
I/O m
odul
e
Input switch
Input switch
Input switch
Input switch
Input switch
Input switch
Input switch
Input switch
Input switch
Input switch
For the icons, refer to pages 217 to 218.
MemoMemoMemo
151 152
Remote I/O modulesRemote I/O modulesProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Screw terminal block type
Overview
Part names and settings
Features
Installation
Screw terminal block type
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. nput derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Module
power
supply
No. of occupied stations
Weight (kg)
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage range
Max. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistance
Res
pons
e tim
e
Voltage
Current consumptionCurrent at start-up
Unit: mm
Unit: mm
Q, bridge
Poi
nt m
ode 4 pts
8 pts
16 pts
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
TYP.MAX.TYP.MAX.
Wiring method for common
Module powersupply
No. of stations occupied
Weight (kg)
0.5ms(high-speed response type)
0.05ms 0.1ms 0.2ms 0.5ms
1.5ms(standard type)
-1.5ms-
1.5ms8 points/common (4 points) (terminal block 2-wire type)20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5 %40mA or lower (with all points ON)70mAFor 4-point mode: 2 stations occupiedFor 8- and, 16-point modes: 1 station occupied (see table on the right)0.09
Response timesetting
Screw T. block
Input module
CL1X4-D1B2
Input module
CL2X8-D1B2
Input switch
Input switch
DC input
pts4 -wire224VDC Screw T. block
DC input
pts8 -wire224VDC Screw T. block
4 pts
8 pts
16 ptsPoi
nt m
ode
Direct or DIN rail mounting is possible
The industry's most compact sizeTerminal block cover with nameplate showing connected devicesInput modules with a shared common (+COM/-COM)Terminal block structure enabling simple connection of 2-wire sensors or other loads
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
Voltage
Current consumption
Current at start-up
Description
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC (-15% to +20%)
Ripple ratio: within 5 %
100% (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6k
0.5 ms/1.5 ms or less (at 24VDC)
0.5 ms/1.5 ms or less (at 24VDC)
4 points/common (2 points)
(terminal block 2-wire type)
20.4 to 28.8VDC (-15% to +20%)
Ripple ratio: within 5%
40mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.06
DescriptionPhotocoupler24VDCApprox. 4mA20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%100% (at 24VDC)19V/3 mA or higher11V/1.7mA or lower5.6k
LED name
PW
L RUN
L ERR.
I/O operation indicator LEDs
ON : LED is on
OFF: LED is off
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
Terminal block
CC-Link/LT interface connector
Description
ON: Power is supplied.
ON: Operating normally
ON: Communication error
Pin No.
4
3
2
1
Signal code
24G
DB
DA
+24V
DIP switch
Setting
Station no.
setting
switch
I/O
operation
setting
The DIP switches are all set to OFF prior to shipment.
Switch name
STATION
NO.
0.5ms
1.5ms
10s
place
1s
place
Description
For input module: response speed setting
OFF: 1.5ms (standard type)
ON : 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON : Output HOLD
For I/O composite module: HOLD function setting
OFF: Output CLEAR
ON : Output HOLD
40
20
10
8
4
2
1
ON : 40
ON : 20
ON : 10
ON : 8
ON : 4
ON : 2
ON : 1
HLD
OFF : 0
ST.No.
1
2
3
4
5
6
7
8
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Actual size
DIN rail mounting
DC24A
DC24B
X0
COMB
X1
X2 X3
COMB
X0 X4X1 COMBDC24A
12345
X0COMBX1X2COMBX3X4COMBX5X6COMBX7
89
101112
67
I/O I/F terminal block (+ common)
I/O I/F terminal block (- common)
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
DC DC
Insulation
DC24A
1314
DC24B
12
DC24ADC24B
Connector for CC-Link/LT interface
Input area externalpower supply
24VDC
Input area externalpower supply
24VDC
CL2X8-D1B2
IN
PW L ERR.L RUN
ON
0 1 2 3 4 5 6 7
LINK/PW
X5
X4
X1
X0
X2
X3
X6
X7
10
40
22
DIN rail center
DIN rail center
4.5
49
64
Input area externalpower supply
24VDC
0 1 2 3PW L RUN L ERR.
LINK/PW
CL1X4-D1B2ON
IN
X1
X0
X2
X3
494.
540
40
10
X1
X0
X2
X3
DC24ADC24BX0COMB
1234
X1X2COMBX3
+24VDADB24G
1234
5678
DC24ADC24B
12
R
R
DC DC
Input area externalpower supply
24VDC
Insulation
I/O I/F terminal block (+ common)
I/O I/F terminal block (- common)
X5 COMB
COMB COMBX2 X3 X6 X7DC24B
50
226
6.5
41±0
.4
41.5±0.4
41±0
.2
55.5±0.4402010 8 4 2 1 0.5ms1.5msSTATION NO.
0 1 2 3PW L RUN L ERR.
LINK/PW
CL1X4-D1B2ON
IN 402010 8 4 2 1 0.5ms1.5msSTATION NO.
40 20 10 8 4 2 1 0.2ms1.5msSTATION NO.
R
R
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw) (2)
2- 4.5 mounting holes (M4 mounting screw)
153 154
Remote I/O modulesRemote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Output specifications
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
Module
power
supply
No. of stations occupied
Weight (kg)
Description
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.1A/point 0.4A/common
0.4A 10ms
0.1mA or lower/30VDC
0.3V or lower (TYP) 0.1A,
0.6V or lower (MAX) 0.1A
1.0ms or less
1.0ms or less
Zener diode
4 points/common (2 points)
(terminal block 2-wire type)
20.4 to 28.8VDC (ripple ratio: within 5%)
60mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.06
Output specifications
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
Output area
external
power supply
Module
power
supply
No. of stations occupied
Weight (kg)
Description
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.1A/point 0.8 A/common
0.7A 10ms or less
0.1mA or lower
0.3V or lower (TYP) 0.1A,
0.6V or lower (MAX) 0.1A
0.5ms or less
0.5ms or less (resistive load)
Zener diode
8 points/common (4 pts)
(terminal block 2-wire type)
Same as load power supply
15mA or lower (at TYP.24VDC and with all
points ON) Not including external load current
20.4 to 28.8VDC (ripple ratio: within 5%)
40mA or lower (with all points ON)
70mA
For 4-point mode: 2 station occupied
For 8- and 16-point modes: 1 station
occupied (see table on the right)
0.09
Output specifications
Isolation method
Max. load current
Rated load voltage
Response
time
Wiring method for common
Contact lifespan
Module
power
supply
No. of stations occupied
Weight (kg)
Q, bridge
4 pts
8 pts
16 pts
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridgeXYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 pts
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Output specifications
Isolation method
Max. load current
Rated load voltage
Response
time
Wiring method for common
Contact lifespan
Module
power
supply
No. of stations occupied
Weight (kg)
Screw T. block
Screw T. blockScrew T. block
Output module
CL1Y4-R1B1
Output module
CL2Y8-TP1B2
Output module
CL1Y4-T1B2
Output module
CL1Y4-R1B2Protection
Hold
HoldHold
Hold
Poi
nt m
ode
Poi
nt m
ode 4 pts
8 pts
16 pts
Q, bridge
Poi
nt m
ode
Poi
nt m
ode 4 pts
8 pts
16 pts
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specificationsDescription
Mechanical isolation
2A/point 4A/common
250VAC or lower, 30VDC or lower
Approx. 10ms or less
Approx. 10ms or less
4 points/common (5 pts)
(terminal block 2-wire type)
200VAC 1.5A,
240VAC 1A (COS =0.7)
100,000 times or more
200VAC 1A,
240VAC 0.1A (COS =0.35)
100,000 times or more
24VDC 1A 100VDC 0.1A (L/R=7ms)
100,000 times or more
20.4 to 28.8VDC (ripple ratio: within 5%)
65mA or lower (with all points ON)
70mA
For 4- , 8- and 16-point modes: 1 station
occupied (see table on the right)
0.11
Description
Mechanical isolation
2A/point 2A/common
250VAC or lower, 30VDC or lower
Approx. 10ms or less
Approx. 10ms or less
1 point/common (independent)
(terminal block 1-wire type)
200VAC 1.5A,
240VAC 1A (COS =0.7)
100,000 times or more
200VAC 1A,
240VAC 0.1A (COS =0.35)
100,000 times or more
24VDC 1A 100VDC 0.1A (L/R=7ms)
100,000 times or more
20.4 to 28.8VDC (ripple ratio: within 5%)
65mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.11
OFF ON
ON OFF
Voltage
Current consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current
consumption
Voltage
Current consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current consumption
Current at start-up
Transistoroutput
pts4 -wire20.1A Screw T. block
pts4Relayoutput
-wire22A
pts4Relayoutput
-wire12A
Transistoroutput
pts8 -wire20.1A
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
DC24V
DC
24G
Y0
COM +
Y1
Y2 Y3
COM +
Y0 Y1 Y4 Y5 COM +COM +
COM + COM +Y2 Y3 Y6 Y7
DC24V
DC24G
NC NC NC
NC NC NC
Y0 Y1 COM1
COM2COM2COM2COM2COM2
Y2 Y3
LINK/PW
CL1Y4-T1B2
Y1
Y0
Y2
Y3
+24VDADB24G
1234
DC24VDC24GY0COM+
1234
Y1Y2COM+Y3
5678
DC DC
Load power supply/output area external
power supply24VDC
L
L
Insulation
+24VDADB24G
1234
I/O I/F terminal block
Load power supply
DC DC
Insulation
RA
LINK/PW
CL1Y4-R1B2
80
Y1
Y0
Y2
Y3
CL2Y8-TP1B2
LINK/PW
PW L ERR.L RUN
ON
HLD40 20 10STATION NO.
Y4Y0
Y5Y1
Y7Y3
Y6Y2
10
64
494.
5
22
40
DIN rail center
Connector for CC-Link/LT interface
Connector for CC-Link/LT interface
DIN rail center
494.
540
40
1050
DIN rail center
494.
540
40
10
40
41.5±0.4
55.5±0.4
41±0
.2
71.5±0.6
41±0
.4
41±0
.4
Unit: mm Unit: mm
Unit: mm Unit: mm
I/O I/F terminal block (sink output)
PW L RUN L ERR.
ON
402010 8 4 2 1HLD
STATION NO.
0 1 2 3
1
6789
10111213141516
NC
NCY0COM 2Y1COM 2Y2COM 2Y3COM 2COM 1COM 2
PW L RUN L ERR.
ON
402010 8 4 2 1HLD
STATION NO.
12345
Y0COM+Y1Y2COM+Y3Y4COM+Y5Y6COM+Y7
89
101112
67
I/O I/F terminal block (sink output)
L
L
DC24V
1314
DC24G
Load power supply/output area external
power supply24VDC
Connector for CC-Link/LT interface
1234
+24VDA
24GDB DC DC
Insulation
226
6.522
66.5
NC NC NC
NC NC NC NC
NC Y0 Y1 Y2 Y3
Y0 Y1 Y2 Y3
LINK/PW
CL1Y4-R1B1
80
Y1
Y0
Y2
Y3
DIN rail center
494.
540
40
10
71.5±0.6
41±0
.4
PW L RUN L ERR.
ON
402010 8 4 2 1HLD
STATION NO.
226
6.5
+24VDADB24G
1234
I/O I/F terminal block
Load power supply
Load power supply
DC DC
Insulation
RA
Connector for CC-Link/LT interface
1
89
10111213141516
NC
NCY0Y0Y1Y1Y2Y2Y3Y3
Constant V. circuit
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw) (2)4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw) (2)
L
L
L
L
155 156
Remote I/O modulesProduct Information
Screw terminal block typeScrew T. block
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Output specifications
Isolation method
Rated load voltage
Operating load
voltage range
Max. load current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method
for common
Description
Photocoupler
12/24VDC
10.2 to 28.8VDC
(ripple ratio: within 5%)
0.1A/point 0.4A/common
0.1mA or lower
0.3V or lower (TYP) 0.1A, 0.6V or lower (MAX) 0.1A
1.0ms or less
1.0ms or less
Zener diode
4 points/common (2 points)
(Terminal block 2-wire type)
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage
range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Module
power
supply
No. of stations occupied
Weight (kg)
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage
range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Module
power
supply
No. of stations occupied
Weight (kg)
Output specificationsMax. load currentRated load voltageResponse timeWiring method for common
Contact life
Description2A/point 4A/common 250VAC or lower, 30VDC or lowerApprox. 10ms or lessApprox. 10ms or less
Output specifications
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
Description
Photocoupler
12/24VDC
10.2 to 28.8VDC (ripple ratio: within 5%)
0.1A/point 0.2A/common
0.1mA or lower
0.3V or lower (TYP) 0.1 A, 0.6V or lower (MAX) 0.1A
1.0ms or less
1.0ms or less
Zener diode
2 points/common (2 points)
(Terminal block 2-wire type)
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage
range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for
common
Module
power
supply
No. of stations occupied
Weight (kg)
Output specifications
Max. load current
Rated load voltage
Response
time
Wiring method for common
Contact lifespan
100000 times or more
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage
range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method
for common
Module
power
supply
No. of stations
occupied
Weight (kg)
100000 times or more
100 thousand times or more
100 thousand times or more
100 thousand times or more
100000 times or more
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridgeXYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 pts
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Screw T. block
Screw T. block
Screw T. block I/O composite module
CL1XY8-DT1B2
I/O composite module
CL1XY8-DR1B2
I/O composite module
CL1XY4-DT1B2
I/O composite module
CL1XY4-DR1B2
Unit: mm Unit: mm
Unit: mm Unit: mm
Screw T. blockDC input
pts2 -wire224VDC
pts2Relayoutput
-wire22A
Hold
Hold Hold
Hold
Poi
nt m
ode 4 pts
8 pts
16 pts
Poi
nt m
ode
Q, bridge
Poi
nt m
ode 4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
Q, bridge
Poi
nt m
ode
OFF ON
ON OFFOFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Description
2A/point 4A/common
250VAC or lower, 30VDC or lower
Approx. 10ms or less
Approx. 10ms or less
2 points/common (3 points)
(Terminal block 2-wire type) 200VAC 1.5A, 240VAC 1A (COS =0.7)200VAC 1A, 240VAC 0.1A (COS =0.35)
24VDC 1A 100VDC 0.1A
(L/R=7ms)
OFF ONON OFF
4 points/common (3 points) (Terminal block 2-wire type) 200VAC 1.5A, 240VAC 1A (COS =0.7)200VAC 1A, 240VAC 0.1A (COS =0.35)24VDC 1A 100VDC 0.1A (L/R=7ms)
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Detailed specifications
OFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Description
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5%
100% (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6k
1.5ms
1.5ms
2 points/common (2 pts)
(Terminal block 2-wire type)
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5 %
55mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.10
Description
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5 %
100 % (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6k
1.5ms
1.5ms
4 points/common (2 points)
(Terminal block 2-wire type)
20.4 to 28.8VDC (24VDC -15 % to +20 %)
Ripple ratio: within 5 %
65mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.10
Description
Photocoupler
24VDC
Approx. 4 mA
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5%
100% (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6k
1.5ms
1.5ms
4 points/common (2 points)
(Terminal block 2-wire type)
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5 %
70mA or lower
(with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.11
Description
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5%
100% (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6k
1.5ms
1.5ms
2 points/common (2 pts)
(Terminal block 2-wire type)
20.4 to 28.8VDC (24VDC -15% to +20%)
Ripple ratio: within 5%
60mA or lower (with all points ON)
70mA
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.11
DC24A
DC24B
DC24V
DC24G
X0 X1
COMB
COMB
X2 X3
COM +
Y3
Y0 Y1
COM + Y2
DC24A
DC24B
X0
COMB
X1
X2 X3
COMB Y0
COM2
Y1
COM2
Y2
COM2 COM1
Y3
DC24A
DC24B
DC24V
DC24G
X0 X1
COMB
NC
COMB NC
Y1
COM+
NC Y0
COM+NC
DC24A
DC24B
X0
COMB
X1
COMB NC
NC NC
NC
Y0
COM2
Y1
COM2 COM2
COM1
DC input
pts2 -wire224VDC Transistor
output
pts2 -wire20.1A DC input
pts4 -wire224VDC Transistor
output
pts4
-wire20.1A
DC input
pts4 -wire224VDC
pts4Relayoutput
-wire22A
0 1 2 3
LINK/PW
CL1XY8-DT1B2
0 1 2 3
80
71.5±0.6
41±0
.4INO U T
Y1
Y0
Y2
Y3
X1
X0
X2
X3
0 1 2 3PW L RUN L ERR.
LINK/PW
CL1XY8-DR1B2
0 1 2 3
ON
INO U T
40 20 10 8 4 2 1ST.NO.
HLD
Y1
Y0
Y2
Y3
X1
X0
X2
X3
DC24ADC24BX0COMB
1234
X1X2COMBX3
5678
DC DCInput area external
power supply24VDC
Input area externalpower supply
24VDC
Input area externalpower supply
24VDC
+24VDADB24G
1234
Y0COM+Y1Y2COM+Y3DC24VDC24G
910111213141516
DC24ADC24B
12
Insulation
DC24ADC24BX0
X1
1234 COMB
X2
X3COMB
5678
DC24ADC24B
12
R
R
Input area externalpower supply
24VDC
I/O I/F terminal block (+ common input)
I/O I/F terminal block (sink output)
I/O I/F terminal block (- common input/ sink output)
Connector for CC-Link/LT interface
I/O I/F terminal block (- common input/ sink output)
Connector for CC-Link/LT interface +24V
DADB24G
1234
Y0COM2Y1COM2Y2COM2Y3COM1
910111213141516
I/O I/F terminal block (sink output)
DC DC
Insulation
I/O I/F terminal block (+ common input)
DIN rail center
494.
540
40
10
80
DIN rail center
494.
540
40
10
71.5±0.6
41±0
.4
PW L RUN L ERR.
ON
402010 8 4 2 1HLD
STATION NO.R
R
RA
226
6.522
66.5
0 1
LINK/PW
CL1XY4-DT1B2
0 1
80
71.5±0.6
41±0
.4
INO U T
X1
X0
0 1PW L RUN L ERR.
LINK/PW
CL1XY4-DR1B2
0 1
ON
INOUT
40 20 10 8 4 2 1ST.NO.
HLD
X1
X0
DC24ADC24BX0COMBX1COMBNCNC
12345678
DC DCInput area external
power supply24VDC
Input area externalpower supply
24VDC
+24VDADB24G
1234
NCNCY0COM+Y1COM+DC24VDC24G
910111213141516
DC24ADC24B
12
Insulation
DC24ADC24BX0COMB
1234
X1COMBNCNC
5678
DC24ADC24B
12
R
R
Input area externalpower supply
24VDC
Input area externalpower supply
24VDC
I/O I/F terminal block (+ common input)
I/O I/F terminal block (sink output)
I/O I/F terminal block (- common input/ sink output)
Connector for CC-Link/LT interface
I/O I/F terminal block (-common input/ sink output)
Connector for CC-Link/LT interface +24V
DADB24G
1234
NCNCY0COM2Y1COM2COM1COM2
910111213141516
I/O I/F terminal block (sink output)
DC DC
Insulation
I/O I/F terminal block (+common input)
DIN rail center
494.
540
40
10
80
DIN rail center
494.
540
40
10
71.5±0.6
41±0
.4
PW L RUN L ERR.
ON
402010 8 4 2 1HLD
STATION NO.
R
R
RA
226
6.522
66.5
Y1
Y0
Y1
Y0
157 158
Remote I/O modulesProduct Information
Screw terminal block typeScrew T. block
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
L
L
L
L
L
L
L
L
2- 4.5 mounting hole (M4 mounting screw)
2- 4.5 mounting hole(M4 mounting screw)
2- 4.5 mounting hole (M4 mounting screw)
2- 4.5 mounting hole(M4 mounting screw)
Spring clampSpring clamp terminal block type
Spring clamp terminal block type
Overview
Part names and settings
CL1X4-D1S2/CL1Y4-T1S2
CL2X8-D1S2/CL2Y8-TP1S2
Features Retightening is not required. Applicable wire size is 0.3 to 1.5mm2 (AWG22 to 16).Two-piece structure (The terminal block is removable.)Input modules have shared commons (negative and positive).
Connect cables to the spring clamp terminal block in the following steps.
* Use the dedicated spring clamp terminal block tool (KD-5339) (refer to page 187). Do not use a general flat-blade screwdriver as it may damage the spring clamp terminal block or its coating.
Wiring cables to spring terminal blockConnect wires
in 3 easy steps!
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
DC24BDC24B
DC24ADC24A
COMBCOMBCOMBCOMBCOMBCOMBCOMBCOMB
X0 X1 X2 X3 X4 X5 X6 X7
LINK/PW
CL2X8-D1S2
ON
1.5ms0.5ms40 20 10 8 4 2 1
STATION NO.
IN
PW L ERR.L RUN 3 4 5 6 7210
LED name
PW
L RUN
L ERR.I/O operation indicator LEDs
ON: LED is on
OFF: LED is off
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
Spring clamp terminal block
CC-Link/LT interface connector
Description
ON: Power is supplied.
ON: Operating normally
ON: Communication error,
or invalid switch setting
Pin No.
1
2
3
4
Signal code
+24V
DA
DB
24G
IN 0.5ms1.5ms
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
Description
10s
place
1s
place
40
20
10
8
4
2
1
ON: 40
ON: 20
ON: 10
ON: 8
ON: 4
ON: 2
ON: 1
OFF:0
HLD
ST.No.
1
2
3
4
5
6
7
8
Actual size
LED name
PW
L RUN
L ERR.I/O operation indicator LEDs
ON: LED is on
OFF: LED is off
CC-Link/LT interface connector
Description
ON: Power is supplied.
ON: Operating normally
ON: Communication error,
or invalid switch setting
Pin No.
1
2
3
4
Signal code
+24V
DA
DB
24G
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
DIP switches are all set to OFF prior to shipment.
Switch name
STATION
NO.
0.5ms
1.5ms
Description
10s
place
1s
place
40
20
10
8
4
2
1
HLD
ST.No.
1
2
3
4
5
6
7
8
Actual size
CL1X4-D1S2
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
CL2Y8-TP1B2
DC24V DC24V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+
40 20 10 8 4 2 1
PW L RUN L ERR.
STATION NO. HLD
ON
OUT
0 1 2 3 4 5 6 7
1 Insert a dedicated tool. 2 Insert a cable. 3 Remove the dedicated tool.
DC24A
DC24B
ON:40
ON: 20
ON: 10
ON: 8
ON: 4
ON: 2
ON: 1
OFF:0
DIN rail mounting
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
Spring clamp terminal block
The DIP switches are all set to OFF prior to shipment.
For input module: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
For input module: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
InstallationDIN rail screw mounting
2- 4.5 mounting holes (M4 mounting screw)
159 160
Remote I/O modulesRemote I/O modulesProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Input module
CL2X8-D1S2Output module
CL2Y8-TP1S2
Input module
CL1X4-D1S2Output module
CL1Y4-T1S2
Unit: mm
Unit: mm
Unit: mm
Unit: mm
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage range
Max. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistanceResponsetime
Wiring method for common
Module power supply
No. of occupied stations
Weight (kg)
8 points/common (8 pts) (terminal block 2-wire type)24VDC (-15% to +20%)Ripple ratio: within 5%40mA or lower (with all points ON)70mA or lowerFor 4-point mode: 2 stations occupiedFor 8- and 16-point modes: 1 station occupied (see table on the right)0.12
Voltage
Current consumptionCurrent at start-up
TYP.MAX.TYP.MAX.
Response timesetting
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush current Leakage current at OFF Max. voltage drop at ON
Response timeSurge suppression Wiring method for common
Module power supply
No. of occupied stations
Weight (kg)
DetailsPhotocoupler12/24VDC10.2 to 28.8VDC (ripple ratio: within 5%)0.1A/point, 0.4A/common0.4A 10ms or less0.1mA or lower0.3V or lower (TYP) 0.1A, 0.6V or lower (MAX) 0.1A1.0ms or less1.0ms or lessZener diode4 points/common (4 points) (terminal block 2-wire type)20.4 to 28.8VDC (24VDC -15% to +20%)Ripple rate: within 5%60mA or lower (with all points ON)
70mAFor 4-, 8- and 16-point modes: 1 station occupied (see table on the right)0.09
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. simultaneous input points Leakage current at OFF Max. voltage drop at ON
Response timeSurge suppression Wiring method for common
Output area external power supplyModule power supply
No. of occupied stations
Weight (kg)
DetailsPhotocoupler12/24VDC24VDC (ripple ratio: within 5%)0.1A/point, 0.8A/common0.7A 10ms or less0.1mA or lower0.3V or lower (TYP) 0.1A, 0.6V or lower (MAX) 0.1A0.5ms or less0.5ms or less (resistive load)Zener diode8 points/common (8 points) (terminal block 2-wire type)10.2 to 28.8VDC (ripple ratio: within 5%)15mA (at 24VDC, with all points ON) Not including external load current24VDC (-15 % to +20 %)Ripple ratio: within 5 %40mA or lower (with all points ON)70mAFor 4-point mode: 2 stations occupiedFor 8- and 16-point modes: 1 station occupied (see table on the right)0.12
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. simultaneous input pointsON voltage/ON currentOFF voltage/OFF currentInput resistanceResponsetime
Voltage
Current consumptionCurrent at start-up
Wiring method for common module power supply
No. of occupied stations
Weight (kg)
0.5ms(high-speed response type)
0.05ms0.1ms0.2ms0.5ms
1.5ms(standard type)
-1.5ms-
1.5ms
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 pts
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 ptsPoi
nt m
ode
Poi
nt m
ode 4 pts
8 pts
16 pts
Q, bridge
Poi
nt m
ode
Poi
nt m
ode 4 pts
8 pts
16 pts
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
OFF ONON OFF
Voltage
Current consumptionCurrent at start-up
OFF ONON OFF
VoltageCurrentconsumptionVoltage
Current consumptionCurrent at start-up
DescriptionPhotocoupler24VDCApprox. 4mA20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%100% (at 24VDC)19V/3mA or higher11V/1.7mA or lowerApprox. 5.6k0.5ms/1.5ms or less (at 24VDC)Selectable by DIP SW (default = OFF / 1.5ms)0.5ms/1.5ms or less (at 24VDC)Selectable by DIP SW (default = OFF / 1.5ms)4 points/common (4 pts) (terminal block 2-wire type)20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5 %40mA or lower(with all points ON)70mAFor 4-, 8- and 16-point modes: 1 station occupied (see table on the right)0.09
DescriptionPhotocoupler24VDCApprox. 4mA24VDC (-15% to +20%)Ripple ratio: within 5%100% (at 24VDC)19V/3mA or higher11V/1.7mA or lowerApprox. 5.6k
DC24GDC24G
DC24ADC24A
COM+COM+COM+COM+COM+COM+COM+COM+
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
LINK/PW
CL2Y8-TP1S2
ON
HLD40 20 10 8 4 2 1STATION NO.
OUT
PW L ERR.L RUN 3 4 5 6 7210
DIN rail center
69
494.
5
4.5
40
226
6.5
41±0
.4
10
60.5±0.4 40
IN 0.5ms1.5ms
DC
24A
DC
24B
X0
COMB
X1
COMB COMB
X2 X3
COMB
DC
24V
DC
24G
Y0
COM+
Y1
COM+ COM+
Y2 Y3
COM+
DC24A
DC24B
DC24BDC24B
DC24ADC24A
COMBCOMBCOMBCOMBCOMBCOMBCOMBCOMB
X0 X1 X2 X3 X4 X5 X6 X7
LINK/PW
CL2X8-D1S2
ON
1.5ms0.5ms40 20 10 8 4 2 1
STATION NO.
IN
PW L ERR.L RUN 3 4 5 6 7210
494.
5 4.5
40
4.5 x 5.1 oblong mounting hole (M4 mounting screw)
10
41±0
.24
60.5±0.4 40
69
4 22
DIN rail center
DC24A
DC24B
X0
COMB
X1
COMB
X2
COMB
X3
COMB
X4
COMB
X5
COMB
X6
COMB
X7
COMB
4940
4.5 x 5.1 oblong mounting hole (M4 mounting screw)
10
41±0
.24
60.5±0.4 40
69
4 22
DIN rail center
DC24V
DC24G
DC24V
DC24G
Y0
COM+
Y1
COM+
Y2
COM+
Y3
COM+
Y4
COM+
Y5
COM+
Y6
COM+
Y7
COM+
12345
Y0COM+Y1COM+Y2COM+Y3COM+
89
10
67
I/O I/F terminal block (sink output)
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
DC DC
Insulation
DC24VDC24G
Connector for CC-Link/LT interface
24VDC
DC24ADC24BX0COMB
1234
X1COMBX2COMBX3COMB
+24VDADB24G
1234
5678910
DC24ADC24B
12
R
R
DC DC
Input area externalpower supply
24VDC
Load voltage
Input area externalpower supply
24VDC
Insulation
I/O I/F terminal block (+ common)
I/O I/F terminal block (- common)
L
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
DC24ADC24BDC24ADC24B
I/O I/F terminal block
R
R
R
R20
12
19
11
18
10
17
9
16
8
15
7
14
6
13
5 X0
DC24V+-
COMB
COMB
X7
X3
COMB
COMB
X6
X2
COMB
COMB
X5
X1
COMB
COMB
X4
Input area external power supply
DC24V+-
Load voltage/I/O external power supply
DC DC
Insulation
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
123456789
1011121314151617181920
DC24VDC24GDC24VDC24G
I/O I/F terminal blockConstant V. circuit
Y0
LCOM+
COM+
Y7
Y3
COM+
COM+
Y6
Y2
COM+
COM+
Y5
Y1
COM+
COM+
Y4
DC DC
Insulation
DIN rail center
69
4940
226
6.5
41±0
.4
10
60.5±0.4 40
Spring clamp Spring clamp
Spring clamp Spring clamp Protection
Input switch
Input switch
DC24A
DC24B
DC input
pts4 -wire224VDC
DC input
pts8 -wire224VDC
Transistoroutput
pts4
-wire20.1A
-wire20.1A
Transistoroutput
pts8Hold
Hold
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw)
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw)
Spring clamp terminal block type
161 162
Spring clamp
Remote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Output module
CL2Y8-TPE1S2
Unit: mm
MemoMemoMemo
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush current Leakage current at OFF Max. voltage drop at ON
Response timeSurge suppression Wiring method for common
External powersupply of theoutput partModule power supply
No. of occupied stations
Weight (kg)
DetailsPhotocoupler12/24VDC10.2 to 28.8VDC (ripple ratio: within 5%)0.1A/point, 0.8A/common0.7A 10ms or less0.1mA or lower0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A1.0ms or less1.0ms or less (resistive load)Zener diode8 points/common (8 points) (terminal block 2-wire type)10.2 to 28.8VDC (ripple rate: within 5%)10mA or lower (24VDC, when all points are ON)Not including external load current24VDC (-15% to +20%)Ripple rate: within 5%40mA or lower (with all points ON)
70mAFor 4-point modes: Occupies 2 stations For 8- or 16-point mode: Occupies 1 station0.13
Poi
nt m
ode 4 pts
8 pts
16 pts
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ONON OFF
VoltageCurrentconsumptionVoltage
Current consumptionCurrent at start-up
Spring clampTransistoroutput
pts8 -wire20.1A HoldProtection
DC24V
DC24G
DC24V
DC24G
Y0
COM-
Y1
COM-
Y2
COM-
Y3
COM-
Y4
COM-
Y5
COM-
Y6
COM-
Y7
COM-
DC24GDC24G
DC24ADC24A
COM-COM-COM-COM-COM-COM-COM-COM-
Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7
LINK/PW
CL2Y8-TPE1S2
ON
HLD40 20 10 8 4 2 1STATION NO.
OUT
PW L ERR.L RUN 3 4 5 6 7210
4.5
4940
4.5 x 5.1 oblong mounting hole(M4 mounting screw)
10
41±0
.24
60.5±0.4 40
69
4 22
DIN rail center
DC24V+-
Load voltage/I/O external power supply
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
123456789
1011121314151617181920
DC24VDC24GDC24VDC24G
I/O I/F terminal block
Y0
LCOM-
COM-
Y7
Y3
COM-
COM-
Y6
Y2
COM-
COM-
Y5
Y1
COM-
COM-
Y4
DC DC
Insulation
Constant V. circuit
4.5 mounting hole (M4 mounting screw)
Spring clamp terminal block type
163 164
Spring clamp
Remote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
CL1X4-D1C3/CL1Y4-T1C2
CL2X8-D1C3V/CL2Y8-TP1C2V
CL2X16-D1C3V/CL2Y16-TP1C2V/CL2XY16-DTP1C5V
Sensor connector type (e-CON)
Sensor connector type (e-CON)
Overview
Part names and settings
Features
Sensor
Open sensor connector (e-CON)
To sensor or valve
Operation indication LEDs
When ON : LED is on
When OFF: LED is off Operation indication LEDs
ON : LED is on
OFF: LED is off
CC-Link/LT interface connector
LED name
PW
L RUN
L ERR.
Description
ON: Power is supplied.
ON: Operating normally
ON: Communication error,
or invalid switch setting
Pin No.
1
2
3
4
Signal code
24G
DB
DA
+24V
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
ST.No.
1
2
3
4
5
6
7
8
Description
10s
place
1s
place
40
20
10
8
4
2
1
ON: 40
ON: 20
ON: 10
ON: 8
ON: 4
ON: 2
ON: 1
OFF: 0
HLD
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
CON1
Actual size
The DIP switches are all set to OFF prior to shipment.
Operation indication
LEDs
ON : LED is on
OFF: LED is off
I/O operation indicator LEDs
ON : LED is on
OFF: LED is off
CC-Link/LT interface connector
LED name
PW
L RUN
L ERR.
Description
ON: Power is supplied.
ON: Operating normally
ON: Invalid switch setting
Pin No.
1
2
3
4
Signal code
+24V
DA
DB24G
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
ST.No.
1
2
3
4
5
6
7
8
Description
10s
place
1s
place
40
20
10
8
4
2
1
ON : 40
ON : 20
ON : 10
ON : 8
ON : 4
ON : 2
ON : 1
HLD
OFF : 0
IN
ST.No.ON1 2 3 4 5 6 7 8
LIN/PW
CL2X8-D1C3V
X
0
1
2
3
4
5
6
7
PW
L RUN
L ERR.
76543210
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
CON1
CON2
CON3
CON4
CON5
CON6
CON7
CON8Actual size
The DIP switches are all set to OFF prior to shipment.
Operation indicator
LEDs
ON : LED is on
OFF: LED is off
I/O operation indicator LEDs
ON : LED is on
OFF: LED is off
CC-Link/LT interface connector
LED name
PW
L RUN
L ERR.
Description
ON: Power is supplied.
ON: Operating normally
ON: Communication error,
or invalid switch setting
Pin No.
1
2
3
4
Signal code
+24V
DA
DB
24G
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
ST.No.
1
2
3
4
5
6
7
8
9*
Description
10s
place
1s
place
40
20
10
8
4
2
1
HLD
Actual size
The DIP switches are all set to OFF prior to shipment.
* Input/output composite module (CL2XY-16-DTP1C5V) only
IN
CON2 CON3 CON4
No.
IN IN
CL2X16-D1C3V
PW
L RUN
L ERR.
LINK/PW
ON87654321
ST.
76543210
76543210
X
0
1
2
3
4
5
6
7
X
8
9
A
B
C
D
E
F
DIN rail mounting hook* Refer page 177 for the DIN rail mounting specifications.
CON9
CON10
CON11
CON12
CON13
CON14
CON15
CON16
CON1
CON2
CON3
CON4
CON5
CON6
CON7
CON8
ON: 40
ON: 20
ON: 10
ON: 8
ON: 4
ON: 2
ON: 1
OFF: 0
For input module: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
For input module: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
For input, I/O composite modules: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
Installationwork
DIN rail mounting.
The industry's most compact sizeAdoption of open sensor connectors (e-CON) for easy sensor connectionSimple module replacement by only disconnecting the connector
165 166
Remote I/O modulesRemote I/O modulesProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Input module
CL2X8-D1C3V
Input module
CL1X4-D1C3
Output module
CL1Y4-T1C2
Unit: mm
Unit: mm Unit: mm
Input module
CL2X16-D1C3V
Unit: mm
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
494.
5
69
23.6
23.6
60.5±0.4
41±0
.4
DIN rail center
226
6.5
10
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24V+V24GX0+24V+V24GX1+24V+V24GX2+24V+V24GX3
Terminal no.CON5-1CON5-2CON5-3CON5-4CON6-1CON6-2CON6-3CON6-4CON7-1CON7-2CON7-3CON7-4CON8-1CON8-2CON8-3CON8-4
Signal code+24V+V24GX4+24V+V24GX5+24V+V24GX6+24V+V24GX7
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4
Signal code+24V+V24GX0+24V+V24GX1
Terminal no.CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24V+V24GX2+24V+V24GX3
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4
Signal code+24VNCNCY0+24VNCNCY1
Terminal no.CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24VNCNCY2+24VNCNCY3
IN
ST.No.ON
1 2 3 4 5 6 7 8
LINK/PW
CL2X8-D1C3V
X
0
1
2
3
4
5
6
7
PW
L RUN
L ERR.
76543210
248
4
39
854
43
DIN rail center
Connector for CC-Link/LT interface
1234 X0
+V+24V
24G R
R
DC DC
Insulation
1234
CON2
X1
+V+24V
24GR
R
1234
CON4
X3
+V+24V
24G
CON1 I/O I/F sensor connector
L
L
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
CON1
Y0
NC+24V
NC
I/O I/F sensor connector
1234
CON2
Y1
NC+24V
NC
1234
CON4
Y3
NC+24V
NC
DC DC
Insulation
1234
+24VDA
24GDB
Connector for CC-Link/LT interface
1234 X0
+V+24V
24G R
R
DC DC
Insulation
2-wire sensor (sink output)
1234
CON2
X1
+V+24V
24GR
R
1234
CON8
X7
+V+24V
24GR
R
CON1 I/O I/F sensor connector
1234
+24VDA
24GDB
IN
494.
5
69
23.6
23.6
60.5±0.4
41±0
.4
R
R
or+COMDC input
pts4
DIN rail center
226
6.5
10
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24VNCNCX0+24VNCNCX1+24VNCNCX2+24VNCNCX3
Terminal no.CON5-1CON5-2CON5-3CON5-4CON6-1CON6-2CON6-3CON6-4CON7-1CON7-2CON7-3CON7-4CON8-1CON8-2CON8-3CON8-4
Signal code+24VNCNCX4+24VNCNCX5+24VNCNCX6+24VNCNCX7
Terminal no.CON9-1CON9-2CON9-3CON9-4CON10-1CON10-2CON10-3CON10-4CON11-1CON11-2CON11-3CON11-4CON12-1CON12-2CON12-3CON12-4
Signal code+24VNCNCX8+24VNCNCX9+24VNCNCXA+24VNCNCXB
Terminal no.CON13-1CON13-2CON13-3CON13-4CON14-1CON14-2CON14-3CON14-4CON15-1CON15-2CON15-3CON15-4CON16-1CON16-2CON16-3CON16-4
Signal code+24VNCNCXC+24VNCNCXD+24VNCNCXE+24VNCNCXF
Connector for CC-Link/LT interface
1234 X0
+V+24V
24G R
R
DC DC
Insulation
2-wire sensor (sink output)
1234
CON2
X1
+V+24V
24GR
R
3-wire sensor (sink output)
(NPN output type)
1234
CON16
XF
+V+24V
24GR
R
CON1 I/O I/F sensor connector
1234
+24VDA
24GDB
43
39
4
85
488 4
No.
IN IN
CL2X16-D1C3V
DIN rail center
PW
L RUN
L ERR.
LINK/PW
ON87654321
ST.
76543210
FEDCBA98
X
0
1
2
3
4
5
6
7
X
8
9
A
B
C
D
E
F
Input switchSensor
-wire224VDC
-wire324VDC
or+COMDC input
pts8Input switchSensor
-wire224VDC
-wire324VDC Vertical
or+COMDC input
pts16Input switchSensor
-wire224VDC
-wire324VDC Vertical
Transistoroutput
pts4Sink
-wire20.1A Sensor Hold
3-wire sensor(NPN output type)
Detectioncircuit
Detectioncircuit
2-wire sensor(NPN output type)
3-wire sensor (sink output)
(NPN output type)
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw) (2)
RDetectioncircuit
Detectioncircuit
RDetectioncircuit
Detectioncircuit
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistanceResponse time
Wiring method for common
I/O power supply maximum allowable currentModule power supply
No. of occupied stations
Weight (kg)
Voltage
Current consumptionCurrent at start-up
TYP.MAX.TYP.MAX.
0.5ms(high-speed response type)
0.05ms 0.1ms 0.2ms 0.5ms
1.5ms(standard type)
-1.5ms-
1.5ms
Response timesetting
8 points/common (sensor connector 3-wire type)1.0A or less/common
20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%40mA or lower (with all points ON)Not including external load current70mAFor 4-point mode: 2 stations occupiedFor 8- and 16-point modes: 1 station occupied (see table on the right)0.05
Q, bridgeXYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
OFF→ONON→OFF
Voltage
Current consumptionCurrent at start-up
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ON
Response timeSurge suppressionWiring method for common
Output area external power supplyModule power supply
No. of occupied stations
Weight (kg)
DescriptionPhotocoupler24VDC20.4 to 28.8VDC (ripple ratio: within 5%)0.1A/point 0.4A/common0.4A 10ms or less0.1mA or lower0.3V or less (TYP) 0.1A, 0.6V or less (MAX) 0.1A1.0ms or lower1.0ms or lowerZener diode4 points/common (sensor connector 3-wire type) Same as module power supply
20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%60mA or lower (with all points ON)70mAFor 4-, 8- and 16-point modes: 1 station occupied (see table on the right)0.04
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage range
Max. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistanceResponse time
Wiring method for common
I/O power supply maximum allowable currentModule power supply
No. of occupied stations
Weight (kg)
Voltage
Current consumptionCurrent at start-up
OFF→ON
ON→OFF
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistanceResponse time
Wiring method for common
I/O power supply maximum allowable currentModule power supply
No. of occupied stations
Weight (kg)
Voltage
Current consumptionCurrent at start-up
TYP.MAX.TYP.MAX.
0.5ms(high-speed response type)
0.05ms 0.1ms 0.2ms 0.5ms
1.5ms(standard type)
- 1.5ms-
1.5ms
Response time setting
16 points/common (sensor connector 3-wire type)1.0A or less/common
24VDC (-15% to +20%) Ripple ratio: within 5%45mA or lower (with all points ON) 70mAFor 4-point mode: 4 station occupiedFor 8-point mode: 2 station occupiedFor 16-point mode: 1 station occupied (see table on the right)0.08
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
4 pts
8 pts
16 ptsPoi
nt m
ode
Poi
nt m
ode
Poi
nt m
ode
Poi
nt m
ode
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
DescriptionPhotocoupler24VDCApprox. 4mA20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%100% (at 24VDC)19V/3mA or higher11V/1.7mA or lower5.6k0.5ms/1.5ms or less (at 24VDC)Selectable by DIP SW (default = OFF / 1.5ms)0.5ms/1.5ms or less (at 24VDC)Selectable by DIP SW (default = OFF / 1.5ms)4 points/common (sensor connector 3-wire type)0.5A or less/common
20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%35mA or lower (with all points ON)70mAFor 4-, 8- and 16-point modes: 1 station occupied (see table on the right)0.04
DescriptionPhotocoupler24VDCApprox. 4mASame as module power supply100% (at 24VDC)19V/3mA or higher11V/1.7mA or lower5.6k
DescriptionPhotocoupler24VDCApprox. 4mASame as module power supply100%19V/3mA or higher11V/1.7mA or lower5.6k
Sensor connector type (e-CON)
167 168
Remote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Sensor
I/O composite module
CL2XY16-DTP1C5V
Output module
CL2Y16-TP1C2
Unit: mm
Output module
CL2Y8-TP1C2V
Unit: mm
Transistoroutput
pts8
-wire20.1A Sensor Hold VerticalProtection
Transistoroutput
pts16
-wire20.1A Sensor Hold VerticalProtection
Transistoroutput
pts8
-wire20.1A
Sensor Hold VerticalProtection
orDC input
pts8 -wire224VDC
-wire324VDC
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ON
ResponsetimeSurge suppressionWiring method for common
Output area external power supplyModule power supply
No. of stations occupied
Weight (kg)
DescriptionPhotocoupler24 VDCSame as module power supply0.1 A/point 1.6 A/common0.7 A 10 ms or less0.1 mA or lower0.3 V or lower (TYP) 0.1 A, 0.6 V or lower (MAX) 0.1 A0.5 ms or less0.5 ms or less (resistive load)Zener diode16 points/common (sensor connector 2-wire type) Same as module power supply24 VDC (-15%+20%) ripple ratio: within 5 %55 mA or lower (with all points ON) Not including external load current70 mAFor 4-point mode: 4 station occupiedFor 8-point mode: 2 station occupiedFor 16-point mode: 1 station occupied (see table on the right)0.08
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. input deratingON voltage/ON currentOFF voltage/OFF currentInput resistanceResponse time
Wiring method for common
I/O power supply maximum allowable currentModule power supply
No. of stations occupied
Weight (kg)
Voltage
Current consumptionCurrent at start-up
TYP.MAX.TYP.MAX.
0.5ms(high-speed response type)
0.05ms 0.1ms 0.2ms 0.5ms
1.5ms(standard type)
- 1.5ms-
1.5ms
Response time setting
8 points/common (sensor connector 3-wire type) 1.0A or less/common
24VDC (-15% to +20%)Ripple ratio: within 5%50mA or lower (with all points ON)
70mA
For 4-point mode: 2 station occupiedFor 8- and 16-point modes: 1 station occupied (see table on the right)0.08
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FXOutput specificationsIsolation method
Rated load voltage
Operating load
voltage range
Max. load current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
Output area external power supply
DescriptionPhotocoupler
24VDC
24VDC (-15% to +20%)
Ripple ratio: within 5%
0.1A/point 0.8A/common
0.1mA or lower
0.3V or lower (TYP) 0.1A,
0.6V or lower (MAX) 0.1A
0.5ms or less
0.5ms or less (resistive load)
Zener diode
8 points/common (2 points)
(sensor connector 2-wire type)
Same as module power supply
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ON
ResponsetimeSurge suppressionWiring method for common
Output area external power supplyModule power supply
No. of stations occupied
Weight (kg)
DescriptionPhotocoupler24 VDCSame as module power supply0.1 A/point 0.8 A/common0.7 A 10 ms or less0.1 mA or lower0.3 V or lower (TYP) 0.1 A, 0.6 V or lower (MAX) 0.1 A0.5 ms or less0.5 ms or less (resistive load)Zener diode8 points/common (sensor connector 2-wire type) Same as module power supply
20.4 to 28.8 VDC (ripple ratio: within 5 %)45 mA or lower (with all points ON) Not including external load current70 mAFor 4-point mode: 2 station occupiedFor 8- and 16-point modes: 1 stationoccupied (see table on the right)0.05
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
Poi
nt m
ode
Poi
nt m
ode
Poi
nt m
ode
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
OFF ON
ON OFF
OFF ONON OFF
VoltageCurrent consumptionCurrent at start-up
OFF ONON OFF
VoltageCurrent consumptionCurrent at start-up
DescriptionPhotocoupler24VDCApprox. 4mASame as module power supply100% (at 24VDC)19V/3mA or higher11V/1.7mA or lower5.6k
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24VNCNCY0+24VNCNCY1+24VNCNCY2+24VNCNCY3
Terminal no.CON5-1CON5-2CON5-3CON5-4CON6-1CON6-2CON6-3CON6-4CON7-1CON7-2CON7-3CON7-4CON8-1CON8-2CON8-3CON8-4
Signal code+24VNCNCY4+24VNCNCY5+24VNCNCY6+24VNCNCY7
Terminal no.CON9-1CON9-2CON9-3CON9-4CON10-1CON10-2CON10-3CON10-4CON11-1CON11-2CON11-3CON11-4CON12-1CON12-2CON12-3CON12-4
Signal code+24VNCNCY8+24VNCNCY9+24VNCNCYA+24VNCNCYB
Terminal no.CON13-1CON13-2CON13-3CON13-4CON14-1CON14-2CON14-3CON14-4CON15-1CON15-2CON15-3CON15-4CON16-1CON16-2CON16-3CON16-4
Signal code+24VNCNCYC+24VNCNCYD+24VNCNCYE+24VNCNCYF
L
Constant V. circuit
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
+24VNCNCY0
I/O I/F terminal blockCON 1
DC DC
Insulation
L 1234
+24VNCNCY1
CON 2
L 1234
+24VNCNCYF
CON 16
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24VNCNCX0+24VNCNCX1+24VNCNCX2+24VNCNCX3
Terminal no.CON5-1CON5-2CON5-3CON5-4CON6-1CON6-2CON6-3CON6-4CON7-1CON7-2CON7-3CON7-4CON8-1CON8-2CON8-3CON8-4
Signal code+24VNCNCX4+24VNCNCX5+24VNCNCX6+24VNCNCX7
Terminal no.CON9-1CON9-2CON9-3CON9-4CON10-1CON10-2CON10-3CON10-4CON11-1CON11-2CON11-3CON11-4CON12-1CON12-2CON12-3CON12-4
Signal code+24VNCNCY0+24VNCNCY1+24VNCNCY2+24VNCNCY3
Terminal no.CON13-1CON13-2CON13-3CON13-4CON14-1CON14-2CON14-3CON14-4CON15-1CON15-2CON15-3CON15-4CON16-1CON16-2CON16-3CON16-4
Signal code+24VNCNCY4+24VNCNCY5+24VNCNCY6+24VNCNCY7
Unit: mm
43
39
4
854
No.
CL2Y16-TP1C2V
DIN rail center
PW
L RUN
L ERR.
LINK/PW
ON87654321
ST.
Y
0
1
2
3
4
5
6
7
Y
8
9
A
B
C
D
E
F
Unit: mm
43
39
4
854
No.
IN
CL2XY16-DTP1C5V
DIN rail center
PW
L RUN
L ERR.
LINK/PW
ON87654321
ST.
9
76543210
X
0
1
2
3
4
5
6
7
Y
0
1
2
3
4
5
6
7
488
488
Connector for CC-Link/LT interface
1234 X0
+V+24V
24G R
R
DC DC
Insulation
2-wire sensor (sink output) 1
234
CON2
X1
+V+24V
24GR
R
Detectioncircuit
3-wire sensor (sink output)
(NPN output type)
1234
CON8
XF
+V+24V
24GR
R
CON1 I/O I/F sensor connector
1234
+24VDA
24GDB
L 1234
+24VNCNCY0
CON 9
L 1234
+24VNCNCY1
CON 10
L 1234
+24VNCNCYF
CON 16
Constant V. circuit
I/O I/F sensor connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON2-1CON2-2CON2-3CON2-4CON3-1CON3-2CON3-3CON3-4CON4-1CON4-2CON4-3CON4-4
Signal code+24VNCNCY0+24VNCNCY1+24VNCNCY2+24VNCNCY3
Terminal no.CON5-1CON5-2CON5-3CON5-4CON6-1CON6-2CON6-3CON6-4CON7-1CON7-2CON7-3CON7-4CON8-1CON8-2CON8-3CON8-4
Signal code+24VNCNCY4+24VNCNCY5+24VNCNCY6+24VNCNCY7
4
8
L ERR.
L RUN
PW
7
6
5
4
3
2
1
0
Y
CL2Y8-TP1C2V
LINK/PW
ONST.No.
24
39
854
43
DIN rail center
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
CON1
Y0
NC+24V
NC
I/O I/F sensor connector
1234
CON2
Y1
NC+24V
NC
1234
CON8
Y7
NC+24V
NC
Constant V. circuit
L
L
DC DC
Insulation87654321
OUT OUT
76543210
FEDCBA98
OUT
76543210
Input switch
RDetectioncircuit
Sensor connector type (e-CON)
169 170
Remote I/O modulesProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Sensor
MIL connector type
MIL connector type
Overview
Part names and settings
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ON
Response timeSurge suppressionWiring method for common
Output area external power supply
Module power supply
No. of stations occupied
Weight (kg)
DescriptionPhotocoupler12/24VDC10.2 to 28.8VDC (ripple ratio: within 5%)0.1A/point 1.6A/common0.7A 10ms or less0.1mA or lower0.3V or lower (TYP) 0.1A, 0.6V or lower (MAX) 0.1A1.0ms or less1.0ms or less (resistive load)Zener diode16 points/common (2 points) (MIL connector 1-wire type) 10.2 to 28.8VDC (ripple ratio: within 5%)15mA or lower (at TYP.24VDC, with all point ON) Not including external load current20.4 to 28.8VDC Ripple ratio: within 5%45mA or lower (with all points ON)
70mA
For 4-point mode: 4 stations occupiedFor 8-point mode: 2 stations occupiedFor 16-point mode: 1 station occupied (see table on the right)0.05
Input specificationsIsolation methodRated input voltageRated input currentOperating voltage rangeMax. simultaneous input pointsON voltage/ON currentOFF voltage/OFF currentInput resistance
Voltage
Current consumptionCurrent at start-up
* For COM+, use either a pin 1 or 2, and 3 or 4.
When a common power supply is used for the output area and load.
*1) Refer to page 171 for derating curve details.
Actual size
16 points/common (2 points) (MIL connector 1-wire type) 20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%45mA or lower (with all points ON)
70mA
For 4-point mode: 4 stations occupiedFor 8-point mode: 2 stations occupiedFor 16-point mode: 1 station occupied (see table on the right)0.05
Wiring method for commonModule power supply
No. of stations occupied
Weight (kg)
TYP.MAX.TYP.MAX.
0.5ms(high-speed response type)
0.05ms 0.1ms 0.2ms 0.5ms
1.5ms(standard type)
- 1.5ms-
1.5ms
Response time setting
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
To I/O devices or terminal block conversion units Refer to page 178.
Input module
CL2X16-D1M1V
Output module
CL2Y16-TP1M1V
Unit: mm
Unit: mm
Installation
Transistoroutput
pts16
-wire10.1A Hold VerticalProtection
4 ps
8 pts
16 pts
4 ps
8 pts
16 ptsPoi
nt m
ode
Poi
nt m
ode
DIN rail mounting.
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Detailed specifications
Response tim
e
OFF ON
ON OFF
OFF ONON OFF
VoltageCurrent consumption
VoltageCurrent consumptionCurrent at start-up
DescriptionPhotocoupler24VDCApprox. 4mA20.4 to 28.8VDC (-15% to +20%)Ripple ratio: within 5%62.5% (at 24VDC) (*1)19V/3mA or higher11V/1.7mA or lower5.6k
Operation indicator LEDs
ON : LED is on
OFF: LED is off
I/O operation indicator LEDs
ON : LED is on
OFF: LED is off
MIL connector (20-pin)
CC-Link/LT interface connector
LED name
PW
L RUN
L ERR.
Description
ON: Power is supplied.
ON: Operating normally
ON: Invalid switch setting
Pin No.
1
2
3
4
Signal code
+24V
DA
DB
24G
DC input
pts16 -wire224VDC Input switch Vertical
I/O I/F MIL connectorTerminal no.CON1-1CON1-2CON1-3CON1-4CON1-20CON1-18CON1-16CON1-14CON1-12CON1-10
Signal codeCOM+COM+COM+COM+X0X1X2X3X4X5
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
CON1COM+COM+COM+COM+
I/O I/F MIL connector
R
R
R
R
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 X0
24VDC
XF
X7
XE
X6
XD
X5
XC
X4
XB
X3
XA
X2
X9
X1
X8
I/O power supply
DC DC
Insulation
Terminal no.CON1-1CON1-2CON1-3CON1-4CON1-20CON1-18CON1-16CON1-14CON1-12CON1-10
Signal codeCTL+CTL+COM-COM-Y0Y1Y2Y3Y4Y5
L
Constant V. circuit
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
CON1CTL+CTL+COM-COM-
I/O I/F MIL connector
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 Y0
L YF
Y7
YE
Y6
YD
Y5
YC
Y4
YB
Y3
YA
Y2
Y9
Y1
Y8
Output area external power supply
Load power supply
L
CTL+COM-COM-
CTL+
YF
DC DC
Insulation
Terminal no.CON1-8CON1-6CON1-19CON1-17CON1-15CON1-13CON1-11CON1-9CON1-7CON1-5
Signal codeX6X7X8X9XAXBXCXDXEXF
I/O I/F MIL connectorTerminal no.CON1-8CON1-6CON1-19CON1-17CON1-15CON1-13CON1-11CON1-9CON1-7CON1-5
Signal codeY6Y7Y8Y9YAYBYCYDYEYF
IN
76543210
89ABCDEF
85424
39
53
FE
CBA98
01234567
L E R R .
L R U N
P W
CL2X16-D1M1V
LINK/PW
ONST.No.
43
DIN rail center
IN
76543210
89ABCDEF
L E R R .
L R U N
P W
CL2X16-D1M1V
LINK/PW
ONST.No.
ST.No.ON
LINK/PW
CL2Y16-TP1M1V
PW
L RUN
L ERR.
85424
39
53
43
DIN rail center
Features
4
4
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
ST.No.
1
2
3
4
5
6
7
8
Description
10s
place
1s
place
40
20
10
8
4
2
1
ON : 40
ON : 20
ON : 10
ON : 8
ON : 4
ON : 2
ON : 1
HLD
OFF : 0
DIP switch
DIN rail mounting hook
* Refer to page 177 for the DIN rail mounting specifications.
1 2 3 4 5 6 7 8
10 20 30 40 500 550
1214
16(Points)
24.0V
26.4V
28.8V
(˚C)
68
10
24
20
18
16
14
12
10
8
6
4
2
19
17
15
13
11
9
7
5
3
1
The DIP switches are all set to OFF prior to shipment.
OUT
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
For input module: response speed setting
OFF: 1.5ms (standard type)
ON: 0.5ms (high-speed response type)
Ambient temperature CL2X16-D1M1VDerating curve
Max
. sim
ulta
neou
s in
put p
oint
s
The industry's most compact size.Supporting MIL connectors that enable simple connection to relay terminals, terminal block conversion units, etc.Simple module replacement by only removing the connector.
171 172
Remote I/O modulesRemote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Output specificationsIsolation methodRated load voltageOperating load voltage rangeMax. load currentMax. inrush currentLeakage current at OFFMax. voltage drop at ON
Response timeSurge suppressionWiring method for common
Output area external power supply
Module power supply
No. of stations occupied
Weight (kg)
DescriptionPhotocoupler12/24VDC10.2 to 28.8VDC (ripple ratio: within 5%)0.1A/point 1.6A/common0.7A 10ms or less0.1mA or lower0.1V or lower (TYP) 0.1A, 0.2V or lower (MAX) 0.1A1.0ms or less1.0ms or less (resistive load)Zener diode16 points/common (2 points) (MIL connector 1-wire type) 10.2 to 28.8VDC (ripple ratio: within 5%)15mA or lower (at TYP.24VDC, with all point on) Not including external load current20.4 to 28.8VDC Ripple ratio: within 5%50mA or lower (with all points ON)
70mA
For 4-point mode: 4 stations occupiedFor 8-point mode: 2 stations occupiedFor 16-point mode: 1 station occupied (see table on the right)0.05
When a common power supply is used for the output area and load.
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Output module
CL2Y16-TPE1M1V
Unit: mm
Transistoroutput
pts16 -wire10.1A Hold VerticalProtection
4 ps
8 pts
16 ptsPoi
nt m
ode
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ONON OFF
VoltageCurrent consumption
VoltageCurrent consumptionCurrent at start-up
MemoMemoMemo
Terminal no.CON1-1CON1-2CON1-3CON1-4CON1-20CON1-18CON1-16CON1-14CON1-12CON1-10
Signal codeCTL-CTL-COM+COM+Y0Y1Y2Y3Y4Y5
L
Connector for CC-Link/LT interface
1234
+24VDA
24GDB
1234
CON1CTL-CTL-COM+COM+
I/O I/F MIL connector
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 Y0
L YF
Y7
YE
Y6
YD
Y5
YC
Y4
YB
Y3
YA
Y2
Y9
Y1
Y8
Output area external power supply
Load power supply
L
CTL-COM+COM+
CTL-
YF
DC DC
Insulation
I/O I/F MIL connectorTerminal no.CON1-8CON1-6CON1-19CON1-17CON1-15CON1-13CON1-11CON1-9CON1-7CON1-5
Signal codeY6Y7Y8Y9YAYBYCYDYEYF
ST.No.ON
LINK/PW
CL2Y16-TPE1M1V
PW
L RUN
L ERR.
85424
39
53
43
DIN rail center
4
OUT
Constant V. circuit
173 174
Remote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
MIL connector type
Cable type
Cable type
Overview Part names and settings
Output specifications
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
I/O flat cable(wire dia.)
Description
Photocoupler
24 VDC
Same as module power supply
0.1 A/point 0.1 A/common
0.4 A 10 ms or less
0.1 mA or lower
1 V or lower (MAX) 0.1 A
1.0 ms or less
1.0 ms or less
Zener diode
1 points/common (1 point)
AWG18 (34/0.18)
Voltage
Current
consumption
Current at start-up
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Wiring method for common
Input resistance
Module
power
supply
No. of stations occupied
Weight (kg)
Output specifications
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Response
time
Surge suppression
Wiring method for common
Module
power
supply
I/O flat cable (wire dia.)
No. of stations occupied
Weight (kg)
Description
Photocoupler
24VDC
Same as module power supply
0.1A/point 0.2A/common
0.4A 10ms or less
0.1mA or lower/30VDC
1V or lower (MAX) 0.1A
1.0ms or less
1.0ms or less
Zener diode
2 points/common (1 point)
20.4 to 28.8VDC (ripple ratio: within 5%)
40mA or lower (with all points ON)
Not including load current.
70mA
AWG18 (34/0.18)
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.07 (includes the 500mm
communication and output cables)
Input specifications
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Wiring method for common
Module
power
supply
I/O flat cable (wire dia.)
No. of stations occupied
Weight (kg)
Actual size
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Q, bridge
XYXYXY
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17FX
Sensor
Output module
CL1Y2-T1D2S
I/O composite module
CL1XY2-DT1D5SInput module
CL1X2-D1D3S
Unit: mm
Unit: mm Unit: mm
Installation
Cable
Cable
Transistoroutput
pts2
-wire20.1A HoldCable
Transistoroutput
pts1
-wire20.1A HoldCable
4 pts
8 pts
16 pts
4 pts
8 pts
16 pts
4 pts
8 pts
16 ptsPoi
nt m
ode
Poi
nt m
ode
Poi
nt m
ode
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Voltage
Current
consumption
Current at start-up
OFF ON
ON OFF
Description
Photocoupler
24VDC
Approx. 4mA
Same as module power supply
100% (at 24VDC)
19V/3mA or higher
11V/1.7mA or lower
5.6 k
0.5ms/1.5ms or less (at 24VDC)
0.5ms/1.5ms or less (at 24VDC)
2 points/common (1 point)
20.4 to 28.8VDC (-15% to +20%)
Ripple ratio: within 5 %
40mA or lower (with all points ON)
Not including input current.
70mA
AWG18 (34/0.18)
For 4-, 8- and 16-point modes: 1 station
occupied (see table on the right)
0.07 (includes the 500mm
communication and input cables)
Description
Photocoupler
24VDC
Approx. 4mA
Same as module power supply
100% (at 24 VDC)
19V/3mA or higher
11V/1.7mA or lower
1 points/common (1 point)
5.6 k
20.4 to 28.8VDC (-15% to +20%)
Ripple ratio: within 5%
40mA or lower (with all points ON)
Not including input and load current.
70mA
For 4-,8- and 16-point modes: 1 station
occupied (see table on the right)
0.07 (includes the 500mm communication
and I/O cables)
DIP switch
Setting
Station
no.
setting
switch
I/O
operation
setting
Switch name
STATION
NO.
0.5ms
1.5ms
10s
place
1s
place
Description
For input module: response speed setting
OFF: 1.5ms (standard type)
ON : 0.5ms (high-speed response type)
For output module: HOLD function setting
OFF: Output CLEAR
ON: Output HOLD
For I/O composite modules: HOLD function setting
OFF: Output CLEAR
ON : Output HOLD
40
20
10
8
4
2
1
ON : 40
ON : 20
ON : 10
ON : 8
ON : 4
ON : 2
ON : 1
HLD
OFF : 0
ST.No.
1
2
3
4
5
6
7
8
Switch
Connector
CL1-HLD
DC input
pts2 or-wire2
24VDC
-wire324VDC
DC input
pts1 or-wire2
24VDC
-wire324VDC
External dimensions & terminal layoutExternal connection diagram
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
Detailed specifications
24G
DA
DB
+24V
DC DC
InsulationCC-Link/LT dedicated flat cable
R
X1
X0
0.5A
0.5A
+24V
24G
R
I/O flat cable
Operation indicator
LEDs
ON : LED is on
OFF: LED is offLED name
PW
L RUN
ON: Power is
supplied.
ON: Operating
normally
Description
I/O operation indicator LEDs
ON : LED is on
OFF: LED is off
24G X0 X1 +24V 24G X0 Y0 +24V
24G Y0 Y1 +24V
20
65
12
20
65
12
24G X0 X1 +24V
24G Y0 Y1 +24V
Blue Black White Brown
500
500
500
500
500
500
20
65
12
Features
CL1X2-D1D3S
CL1Y2-T1D2S
CL1XY2-DT1D5S
402010 8 4 2 10.5ms1.5ms
402010 8 4 2 1
402010 8 4 2 1
0
24G
DA
DB
+24V
DC DC
InsulationCC-Link/LT dedicated flat cable
Y1 L
LY0
+24V
24G
I/O flat cable
Internalcircuit
R
24G
DA
DB
+24V
DC DC
InsulationCC-Link/LT dedicated flat cable
Y0
X0
+24V
24G
I/O flat cable
Internalcircuit
R
R
R
With cover open
24G X0 Y0 +24V
L
0.5A
0.5A
The DIP switches are all set to OFF prior to shipment.
CC-Link/LT dedicated flat cable
I/O flat cable
Refer to page 177 for cable connection examples.
* The cable type I/O module has a dedicated flat cable connected directly. Therefore, the module-side cable length should not exceed 20cm when connecting a VCTF cable or a flexible cable.
175 176
Remote I/O modulesRemote I/O modulesProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Internalcircuit
Input switch
The industry's most compact size.Can be housed in a duct like cables.Integration of communication cables and external device connection cables for easy wiring.
Lamp, solenoid, etc.
Insulated crimp connector or closed-end connector, etc.
Screw T. block
Screw T. block
Sensor
Sensor
MIL
MIL
Screw T. block
Spring clamp
Spring clamp
0.3
0.35
0.3
0.3
Remote I/O module information
Optional parts for MIL connector type
The following units convert a MIL connector type remote I/O module into a terminal block type and can be used as relay terminal blocks or in-panel relays.
The cable length from the module to a sensor shall be 3m or less. Measure the sensor’s drive voltage externally to ensure a proper voltage.
* Using a holder together allows the cable type module mounting with both DIN rail and screws.
When the diameter of an I/O device connection cable is same as that of the I/O flat cable, it can be connected through a CC-Link/LT dedicated connector.
30mm 30mmInsulated crimp connector or closed-end connector, etc.
Sensor, switch, etc.
CC-Link/LT dedicated connector Wire dia.:AWG18 (34/0.18)
Output device
Input device
Cable handlingDo not bend the cable in the area within 30mm from the module.
Outputmodule
Outputmodule
Resistor Load Inductance Load
The following explains input circuit troubleshooting.
The following explains the precautions and specifications for selecting the remote I/O modules available for the CC-Link/LT system.(1) When using the output module to drive a load L, the
maximum switching frequencies should be ON for 1s or more and OFF 1s or more.
(2) When the counter or timer that uses a DC/DC converter as a load is used with the transistor output module of
maximum load current 0.1A, a rush current will flow at given intervals when it is ON or operating. Therefore, selecting the output module in terms of an average current can cause a malfunction or failure.When using the above load, connect a resistor or inductance in series with the load to reduce the influence of the rush current, or use an output module that has a larger maximum load current.
Inputmodule
Leakage current
DC input (sink)
Inputmodule
DC input (sink)
Resistor
Inputmodule
DC input
E1
E1>E2
E2
Inputmodule
DC input
E1 E2
Condition
Cause
CorrectiveAction
Example 1 Example 2
Input signal does not turn off. Input signal does not turn off.
The connected LED indicator switch feeds a 4mA leakage current when 24VDC power is input to the input module
(1) The input signal will not turn off since the OFF current of the input module does not satisfy 1.7mA. Therefore, connect a resistor as shown below.
(2) Calculate the resistor value, R, so that a 2.3mA or higher current will flow in the resistor to be connected in order to satisfy the 1.7mA OFF current of the input module.
(3) Using a safety factor of 3 to 5 to select the power capacity of the resistor for the actual power consumption, connect the resistor 3.9kW, 1W.
Inputmodule
24VDC
Leakage current4mA
Inputimpedance
24VDC
4mA
IR=2.3mA
IZ=1.7mA
R Z
IR:IZ=Z (Input impedance) : R
The following table provides input circuit troubleshooting methods. (Those of the sensor and cable type remote I/O modules are not included.)
Precautions when selecting a remote I/O module
Input circuit troubleshooting
<Calculation example for Example 1>
IR 2.3
Leakage current due to the LEDindicator switch
Connect a proper resistor as shownon the right to drop the voltageacross the input terminal and COM1below the OFF voltage.
Current flow due to use of two power supplies
Use a single power supply.Connect a diode to prevent a current flow (as shown on the right).
R is less than 4.1k . When the resistor R is 3.9 k , the power capacity W of the resistor R is as follows.
R IZ
(Input impedance) = 1.7
5.6 = 4.1
Input Output
Ceilingmounting
Front mountingFront mounting
Flat surfacemounting
DIN rail
Screw
SpecificationsType Details
DIN-rail mounting,
TH35-7.5Fe, TH35-7.5AI
(compliant with to JIS C 2812 standard)
Screw mounting: M4 x 0.7mm x 16mm or more
(Tightening torque range is 78 to 108N/cm)
* 4-point type sensor connector only.
Specifications Details
Applicable crimp terminal / wire size
DIN-rail mounting example Mountable in 6 postures
Cable
Cable type connection examples I/O flat cable connection example (for I/O composite module)
Terminal block type wiring specifications
Mounting
Terminal block conversion unit list
RAV1.25-3 (compliant with to JIS C 2805 standard) V1.25-3 (JST Mfg., Co., Ltd.) 1.25-3, TG1.25-3 (Nichifu Moris) (Applicable wire size: 0.3 to 1.25mm2)
Appearance Model Input points Output points Function External dimensions (mm)
FX-16EX-A1-TB
FX-32E-TB
FX-16E-TB
A6TE2-16SRN
Terminal block conversion DC input signal type
AC input signal type
Relay output type
16 -
32 -
16 -
- 16
150
55
45
180
67
40
150
55
45
150
55
45
Weight (kg)
1) FX-16E-150CAB (1.5m)2) FX-16E-300CAB (3m)3) FX-16E-500CAB (5m)
Appearance Model Description
FX-16E-500CAB-S (5m)
1) FX-16E-150CAB-R (1.5m)2) FX-16E-300CAB-R (3m)3) FX-16E-500CAB-R (5m)
Appearance Model Description
Appearance Model Description
FX2C-I/O-CON
Appearance Model Description
1) FX2C-I/O-CON-S2) FX2C-I/O-CON-SA
Flat cable connector AWG28 (0.1mm2): 10-piece setCrimp connector: FRC2-A020-30S 1.27 pitch, 20-coreOptional crimp tool (357J-5538) made by DDK, Ltd.
1. Connecter for singlewiresAWG22 (0.3mm2): 5-piece setHousing: HU-200S2-001Solderless contact: HU-411SOptional solderless tool (357J-5538) made by DDK, Ltd.
2. Connecter for singlewiresAWG20 (0.5mm2): 5-piece setHousing: HU-200S2-001Solderless contact: HU-411SAOptional solderless tool (357J-13963) made by DDK, Ltd.
Terminal block conversion unit connection cable list
MIL connector type connector & cable
I/O cable for terminal block20-pin connectors attached to both ends of a flat cable (with tube)
I/O cable for terminal block20-pin connectors attached to both ends of a round multi-core cable
General-purpose I/O cableA 20-pin connector attached to one end of single wires
177 178
Remote I/O ModulesRemote I/O modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
CH1
CH2
CH3
CH4
0~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFF
OFFOFFOFFOFFOFF
0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW
L ERR.RUN
9 107 85 63 4
4 5 6 7 8 9 1 2
1 2 310
ON
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.
0 1 2NC
DIN rail mountingCH1
CH2
CH3
CH4
0~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFF
OFFOFFOFFOFFOFF
0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW
L ERR.RUN
9 107 85 63 4
4 5 6 7 8 9 1 2
1 2 310
ON
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.
0 1 2NC
Screw terminal block type
Screw terminal block type
Overview Part names and settings
Installation
Screw T. block
DIN rail mounting.
4.5 mounting hole (M4 mounting screw) (2)
Common Terminal Block
Convenient!
Features
CH1
CH2
0 10V-10 10V
0 5V1 5V
0 20mA
ONON
ONONON
ON
ON
OFF
OFF OFFOFF
OFF OFF
OFF OFF
OFFOFFOFF0 1 2
SWITCH MODEFUNCTION4 20mA
ON ON
ONONON
OFF
L RUNPW L ERR.RUN
9 107 85 63 44 5 6 7 8 9 1 21 2 3 10
ON
CH4
CH3
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.0 1 2
NC
9 107 85 63 44 5 6 7 8 9 1 21 2 3 10
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.0 1 2
NC
2) 3) 4)
9 107 85 63 44 5 6 7 8 9 1 21 2 3 10
NCCH2CH1
402010 8 4 2 1 0 1 2STATION NO.
0 1 2HLD
2) 5) 4) 3)
PWRUN
L RUN
L ERR.
LED name Description
1) Operation status indicator LEDs
ON: Power is on. OFF: Power failure or large voltage dropON: Module operating normallyFlashing: All channels are set to “Conversion disable” by Analog
input setting switch. Setting of Analog input setting switch was changed during operation. Or, NC is switched ON.
OFF: Watchdog timer error or hardware failureON: Normal communicationOFF: Communication failure (timeout error)ON: Communication data error
Station number switch setting is invalid. Other than 16-point mode is set. Communication is interrupted (timeout error). Or, all channels are set to “Conversion disable” by Analog input setting switch.
Flashing at regular intervals (0.4s): Station number setting switch was changed after power-on.
Flashing at irregular intervals: A terminating resistor is missing. The module or cables are affected by noise.
OFF: Communication is normal.
Set the 10s place using “10”, “20” and/or “40” of STATION NO.Set the 1s place using “1”, “2”, “4” and/or “8” of STATION NO.Be sure to set a station number within the range from 1 to 64.Setting any other invalid value will generate an error, lighting up the “L ERR.” LED. Duplicate station number setting is not allowed.
Terminal block
Left face
DIN rail mounting hookThis hook is used to mount the module on the DIN rail.
CC-Link/LT interface connectorConnector for CC-Link/LT communication line and module power supply connection (optional)
Cable guideUsed when direct-connection cable is connected in a downward direction.
2) Station number setting switch
The DIP switches are all set to OFF prior to shipment.
Switch nameSTATIONNO.
Station no.40
OFFOFFOFFOFF
:OFFOFF
:ON
10s place20
OFFOFFOFFOFF
:OFFOFF
:ON
1s place10
OFFOFFOFFOFF
:ONON
:OFF
8OFFOFFOFFOFF
:OFFOFF
:OFF
4OFFOFFOFFON
:OFFOFF
:ON
2OFFONONOFF
:OFFOFF
:OFF
1ONOFFONOFF
:OFFON
:OFF
1234:
1011:
64
Specify whether to enable or disable A/D conversion and an input range for each channel. For unused channels, set the conversion to be disabled.
4) Analog input setting switchSwitch nameCH1 to 4
Description
Description
Input range
4 to 20mA0 to 20mA
1 to 5V0 to 5V
-10 to 10V0 to 10V
0OFFOFFOFFOFFONONONON
Setting switch1
OFFOFFONONOFFOFFONON
2OFFONOFFONOFFONOFFON
Conversionenable
Conversion disable
3) NCNot used (System use only)This must be OFF at all times. Turning it ON will flash the RUN LED.5) HOLD/CLEAR selector switchSet whether to retain or hold analog values when communications are interrupted. (This setting applies to all channels.)OFF: ClearON: Hold
Screw terminal block
CL2TE-5 Applicable model: CL2AD4-B
When using an output moduleAttaching the common terminal block to the above analog module and using a shielded cable make the cable grounding easy.
Included: 1 daisy chain cable with solderless terminal (100mm)
CH1
CH2
CH3
CH4
0~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFF
OFFOFFOFFOFFOFF
0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW
L ERR.RUN
9 107 85 63 4
4 5 6 7 8 9 1 2
1 2 310
ON
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.
0 1 2NC
Efficient usage of I/O points (No. of stations occupied) is available because the points can be changed by the preset conversion-enabled channel.(No. of stations occupied changes depending on the setting of the channel for which conversion is enabled.)Dedicated flat cable (50cm) is directly connected to a module.
CL2AD4-B
CL2DA2-B
179 180
Analog modulesAnalog modulesProduct Information
Actualsize
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Input specifications
Analog
input
Digital value
I/O characteristics
* Accuracy (accuracy
relative to maximum
digital output value)
Conversion speed
Absolute max. input
Analog input points
CC-link/LT station type
No. of stations occupied
Isolation method
Connection terminal block
Applicable wire size
Applicable solderless
terminal
Installation
Applicable DIN rail
Module
power
supply
Weight (kg)
Voltage
Current
consumption
Current at start-up
200µs/4 channels *4
Voltage: ±15V Current: ±30mA
4 channels/module
Remote device station
Four 16-point-mode stations *5
Across communication system terminals and all analog input terminals: Photocoupler isolation, transformer isolation
Across power supply system terminals and all analog input terminals: Photocoupler isolation, transformer isolation
Across communication system terminals and power supply system terminals: Photocoupler isolation, transformer isolation
Between channels: Not isolated
Directly mounted 14-point terminal block (M3 screws)
0.3 to 1.25 mm2
RAV1.25-3 (compliant with JIS C 2805), V1.25-3 (J.S.T. Mfg Co., Ltd.), 1.25-3, TG1.25-3 (NICHIFU Co. Ltd.)
DIN rail mounting, screw mounting: M4 x 0.7mm x 16mm or more.
Mountable in 6 orientations.
TH35-7.5Fe, TH35-7.5Al (compliant with JIS C 2812)
24VDC (20.4 to 28.8VDC, ripple ratio: within 5%)
0.125A
-
0.20
Analog input module
CL2AD4-B
Unit: mm
Voltage
Current
-10 to +10V
0 to 10V
0 to 5V
1 to 5V
0 to 20mA
4 to 20mA
-4000 to +4000
0 to 4000
0 to 4000
±0.4%
(±16digit *2)
±0.2%
(±8digit *2)
2.5mV
1.25mV
1.0mV
5µA
4µA
Analog input
rangeAmbient
temperature
0 to 55°C
Ambient
temperature
25±5°C *1
Digital value Max. resolution
Accuracy
±80ppm/˚C(±0.008%/˚C)
Temperature
coefficient *3
Voltage
Current
Output specifications
Digital
value
Analog
output
I/O characteristics,
max. resolution
* Accuracy (accuracy
relative to maximum
digital output value)
Conversion speed
Output short-circuit
protection
Absolute max. output
Analog input points
CC-link/LT station type
No. of stations occupied
Isolation method
Connection terminal block
Applicable wire size
Applicable solderless terminal
Installation
Applicable DIN rail
Module
power
supply
Weight (kg)
Voltage
Current
consumption
Current at start-up
200µs/2 channels
Provided
Voltage: ±12V Current: ±21mA
2 channels/module
Remote device station
Two 16-point-mode stations *3
Across communication system terminals and all analog output terminals: Photocoupler isolation, transformer isolation
Across power supply system terminals and all analog output terminals: Photocoupler isolation, transformer isolation
Across communication system terminals and power supply system terminals: Photocoupler isolation, transformer isolation
Between channels: Not isolated
Directly mounted 14-point terminal block (M3 screws)
0.3 to 1.25 mm2
RAV1.25 to 3 (compliant with JIS C 2805), V1.25-3 (J.S.T. Mfg Co., Ltd.), 1.25-3, TG1.25-3 (NICHIFU Co. Ltd.)
DIN rail mounting, screw mounting: M4 x 0.7mm x 16mm or more.
Mountable in 6 orientations.
TH35-7.5Fe, TH35-7.5Al (compliant to JIS C 2812)
24 VDC (20.4 to 28.8 VDC, ripple ratio: within 5 %)
0.250A
-
0.20
Analog output module
CL2DA2-B
Unit: mm
Screw T. block
Voltage
Current
-10 to +10V
0 to 10V
0 to 5V
1v5V
0 to 20mA
4 to 20mA
-4000 to +4000
0 to 4000
0 to 4000
±0.4%
(±40mV)
±0.4%
(±20mV)
±0.4%
(±80µA)
±0.2%
(±20mV)
±0.2%
(±10mV)
±0.2%
(±40µA)
2.5mV
1.25mV
1.0mV
5µA
4µA
Analog output
rangeAmbient
temperature
0 to 55°C
Ambient
temperature
25±5°C *1
Digital value Max. resolution
Accuracy
±80ppm/˚C(±0.0080%/˚C)
Temperature
coefficient *3
Voltage
Current
Voltage
Current
Screw T. block
Screw T. block
Remotedevice
*1: Reference accuracy*2: Accuracy for each 1 degree ˚C temperature change*3: The number of occupied I/O points (stations) varies depending on the final channel for which conversion is enabled.*4: Power is supplied from a power supply module or a power supply adapter.
*1: Reference accuracy*2: 1digit refers to one output digital unit.*3: Accuracy for each 1 degree ˚C temperature change*4: When the first order lag filter is used, the conversion speed of the first order lag filter channel is 400µ s.*5: The number of occupied I/O points (stations) varies depending on the final channel for which conversion is enabled.*6: Power is supplied from a power supply module or a power supply adapter.
Screw terminal block type
st.s4Occupied
CH4Channel Remote
devicest.s2Occupied
CH2Channel
External dimensions & terminal layout
External connection diagram
Detailed specifications
External dimensions & terminal layout
External device connection diagram
Detailed specifications
Description
-10 to +10VDC (input resistance 1M )
0 to 20mA DC (input resistance 250 )
15-bit signed binary (-4096 to +4095)
Description
15-bit signed binary (-4096 to 4095)
15-bit signed binary (-96 to 4095)
-10 to +10VDC (external load resistance: 1k to 1M )
0 to 20mA DC (external load resistance: 0 to 600 )
4.6
4 8
4 9
49
4
CH1
CH2
69
22
10
9.4
29
4021
40~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFFOFFOFF
OFFOFFOFF0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONONON NO CONVERTOFF
L RUNPW L ERR.RUN
9 107 85 63 44 5 6 7 8 9 1 21 2 3 10
ON
(55)(51)
CH4
CH3
CL2AD4-B
CH40 1 2
CH30 1 2
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.0 1 2
NC
Cable length: 500mm
DIN railcenter41
±0.2
60.25±0.4
V+I+
V-/I-
V+I+
V-/I-
FG
CH1 +15V
-15VANALOG GND
ANALOG GND
*1 Shield
*1 Shield*4
*3
CH4
*2
Signal source: 0 to ±10V
In case of voltage input
Signal source: 0 to ±20mA
In case of current input
AG
*2
+15V
-15V
V+I+
V-/I-
V+I+
V-/I-
FG
CH1 +15V
-15VANALOG GND*1 Shield
*1 Shield*4
*3
CH4
*2
Signal source: 0 to ±10V
In case of voltage input
Signal source: 0 to ±20mA
In case of current input
AG
*2
ANALOG GND
+15V
-15V
1 COM
2 COM
3 COM
4 COM
5 COM
CL2TE-5 *5
D/Aconversion V+
COM
*1Motor drive module, etc.
GND
CH1
to
toV+
COM
Motor drive module, etc.
GND
CH2
to
to
D/Aconversion I+
COM
*1Motor drive module, etc.
GND
CH1
I+
FG FG
COM
Motor drive module, etc.
GND
CH2
1
AG
3CH1V+
5CH1V-/I-
7CH2
I+
9CH3V+
11CH3V-/I-
13CH4
I+
2
FG
4CH1
I+
6CH2V+
8CH2V-/I-
10CH3
I+
12CH4V+
14CH4V-/I-
4.6
4 8
4 9
49
4
CH1
CH2
69
22
10
9.4
29
4021
40~10V
-10~10V0~5V1~5V
0~20mA
ONONON
ONONON
ON
OFFOFFOFF
OFFOFF OFFOFFOFF
OFFOFFOFF0 1 2
SWITCH MODEFUNCTION4~20mA
ON ONON ONON NO CONVERT
OFF
L RUNPW L ERR.RUN
9 107 85 63 44 5 6 7 8 9 1 21 2 3 10
ON
(55)(51)
CL2DA2-B
CH2CH1402010 8 4 2 1 0 1 2
STATION NO.0 1 2
HLD NC
Cable length: 500mm
DIN railcenter41
±0.2
60.25±0.4
1 3CH1V+
5CH1
I+
7CH2V+
CH2I+
9 11 13
2
FG COM COM
4 6 8 10 12 14
*1 Use a 2-core twisted shield wire.*2 Indicates input resistance of the CL2AD4-B.*3 In the case of current input, be sure to connect (V+) and (I+)
terminals.*4 Be sure to ground FG. AG should be also grounded in the case of
frequent noise.*5 Using the CL2TE5 allows grounding of all shield wires.
*1 Use a 2-core twisted shield wire.*2 Indicates input resistance of the CL2AD4-B.*3 In the case of current input, be sure to connect (V+) and (I+)
terminals.*4 Be sure to ground FG. AG should be also grounded in the case of
frequent noise.
*1 Use a 2-core twisted shield wire. *1 Use a 2-core twisted shield wire.
With a CL2TE-5 common terminal block Without a CL2TE-5 common terminal block
4.5 Mounting hole (M4 mounting screw) (2)
4.5 Mounting hole (M4 mounting screw) (2)
Voltage output Current output
500k
500k
500k
500k250
500k
500k
500k
500k250
1k
1M
1k
1M
0
600
0
600
181 182
Analog modulesProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Dedicated power supply/Power supply adapter
CL1PAD1 Power supply adapter
Unit: mm
Unit: mm
CL1PSU-2A Power supply
External dimensions
Terminal layout
External connection diagram
Detailed specifications
Features
Terminal layout
Specifications
Voltage input range
Max. rated current
Insulation
resistance
External wiring
method
Weight (kg)
Connector for CC-Link/LT I/F
1234
--DA
--DB
1234
123
External power supply24VDC 5A
Internalcircuit
Connector for CC-Link/LT I/F
Power supply adapterPower terminal block
+24VDA
24GDB
LINK LINK/POWER
This power supply adapter is designed to stabilize the whole system when power is supplied from the external power supply to the CC-Link system.
24G
+24V
+-
L N
Connector for CC-Link/LT I/F
1234
--DA
--DB
1234
123
Connector for CC-Link/LT I/F
LINK LINK/POWER
Dedicated power supplyPower terminal block
Class D grounding
100/120/200/230/240VAC(allowable voltage range: 85 to 264VAC)
+24VDA
24GDB
LINK LINK/POWER
* In regular operation, use so that the max. rated current is not exceeded. (Refer to 184 page)
Specifications
Noise immunity
Withstand voltage
Allowable instantaneous
power failure period
Insulation
resistance
External wiring
method
Weight (kg)
Rated voltage
Allowable voltage range
Rated frequency
Power fuse
Inrush current
Output voltage
Output current
Ripple noise
Overvoltage
protection
Overcurrent
protection
The CC-Link/LT system requires 1 or more of these modules. (*)
The CC-Link/LT system dedicated power supply has a built-in 2A power supply.
66 9010
75–0
.2 85
5
43
DIN rail center
Internalcircuit
LED24V
9090
90
82–0.3
8
82–0
.3 CL1PSU-2A
AC85- 264V
MITSUBISHI
24V
LINKDBDA
LINK/POWER
24GDBDA
+24V
L N
45
DIN rail center
LED24V
Selecting a power supply
CC-Link/LT system’s current consumption
Total current consumption of each CC-Link/LT module (see table below)
Current consumption (mA)
404035604045455550455550404040
Module typeMaster/Bridge modules
Screw terminal block type
Spring clamp terminal block type
Current consumption (mA)
28257540606565404055606570406040
Module typeSpring clamp terminal block typeSensor connector type
MIL connector type
Cable type
Model nameCL2Y8-TP1S2CL2Y8-TPE1S2CL1X4-D1C3CL1Y4-T1C2CL2X8-D1C3VCL2Y8-TP1C2VCL2X16-D1C3VCL2Y16-TP1C2VCL2XY16-DTP1C5VCL2X16-D1M1VCL2Y16-TP1M1VCL2Y16-TPE1M1VCL1X2-D1D3SCL1Y2-T1D2SCL1XY2-DT1D5S
Specifications8-point terminal block 0.1A Tr source output8-point terminal block 0.1A Tr output4-point sensor connector 24VDC input4-point sensor connector 0.1A Tr output8-point sensor connector 24VDC input8-point sensor connector 0.1A Tr output16-point sensor connector 24VDC input16-point sensor connector 0.1A Tr output16-point terminal block 24VDC input/2A relay output16-point MIL connector 24VDC input16-point MIL connector 0.1A Tr output16-point MIL connector 0.1A Tr source output2-point cable type 24VDC input2-point cable type 0.1A Tr output2-point cable type 24VDC input/0.1A Tr output
Model nameQJ61CL12FX2N-64CL-MAJ65SBT-CLBCL1X4-D1B2CL1Y4-T1B2CL1Y4-R1B2CL1Y4-R1B1CL2X8-D1B2CL2Y8-TP1B2CL1XY4-DT1B2CL1XY4-DR1B2CL1XY8-DT1B2CL1XY8-DR1B2CL1X4-D1S2CL1Y4-T1S2CL2X8-D1S2
SpecificationsCC-Link/LT master module for Q seriesCC-Link/LT master module for FX seriesCC-Link - CC-Link/LT bridge module4-point terminal block 24VDC input4-point terminal block 0.1A Tr output4-point terminal block 2A relay output4-point terminal block 2A relay output8-point terminal block 24VDC input8-point terminal block 0.1A Tr output4-point terminal block 24VDC input/0.1A Tr output4-point terminal block 24VDC input/2A relay output8-point terminal block 24VDC input/0.1A Tr output8-point terminal block 24VDC input/2A relay output4-point terminal block 24VDC input4-point terminal block 0.1A Tr output8-point terminal block 24VDC input
Total current consumption of all I/O devices (sensors, etc.)
**
***
Module typeScrew terminal block type
Current consumption (mA)
12.525
Model nameCL2AD4-BCL2DA2-B
Specifications4-channel voltage/current input2-channel voltage/current input
1) Current consumption calculation
2) Voltage drop calculation
1) Current consumption calculation (with power supply adapter (CL1PAD1))
1) Current consumption calculation
3) Starting current calculation
The CC-Link/LT system requires one or more dedicated power supply (CL1PSU-2A) or power supply adaptor (CL1PAD1). The number of required power supply adaptors is obtained by 1) and 2).
A general-purpose power supply must be prepared to drive the CC-Link/LT system. The general-purpose power supply’s current capacity is obtained by 1) and 3) below.
When the following conditions 1) Current consumption calculation and 2) Voltage drop calculation are satisfied, one dedicates power supply or power supply adapter is enough for normal system operation. If not satisfied, 2 or more power supplies or power supply adapters are required.
YES
YES
NO
NO
NO
Power supply adaptor installation
Consider using multiple power supply adaptors in the system.
Select on appropriate power supply for the CC-Link/LT system, considering the following 3 check points.
Number of dedicated power supplies or power supply adaptors
Power supply adaptor installation: Number of power supply adaptors
General-purpose power supply selection (for power supply adaptor): General-purpose power supply’s current capacity
* The FX3uc PLC has an internal 350mA power supply. For details, refer to the "FX3uc PLC User's Manual (Hardware Edition)".
The operation voltage for the CC-Link/LT system must be maintained at 20.4V or higher. For selection and power supply capacity calculation (technical information), refer to page 177.
Completed
Voltage dropcalculation
(separate manual)
Total current consumption
General-purpose power supply selection
3) Starting current calculation
1) Current consumption calculation
2) Voltage drop calculation(Simple calculation)
External dimensionsExternal connection diagram
Detailed specifications
Features
4.5 mounting hole (M4 mounting screw) (2)
4.5 mounting hole (M4 mounting screw) (2)External power supply should be provided by the customer.
InputO
utputP
rotectionfunction
As the module marked with an asterisk (*) in the table below supplies power to I/O devices, its value must be included in the current consumption of the CC-Link/LT system.
Because the current capacity for 1 power supply adaptor is 5A, the total current consumption is less than or equal to 5A.
List of CC-Link/LT modules and their current consumption Remote I/O modules
Analog module
5A
Voltage drop 3.6V
Voltage drop 3.6V
Description
100/120/200/230/240VAC
85 to 264VAC
50/60Hz
3.15A
Max. 60A/200VAC
24VDC +10% / -5%
0.01A to 2A derating according to ambient
temperature and line voltage [The current
consumption should not exceed 2A when power is
supplied (excluding immediately after power ON).]
500mVp-p or less
Noise voltage 1000Vp-p, noise width 1µs, noise
carrier frequency 25 to 60Hz (by noise simulator)
AC type 1500VAC for 1 minute
DC type 500VAC for 1 minute
Operation continues at momentary power
outages of 10ms or less.
Across all external terminals and ground terminal,
10M by 500VDC insulation resistance tester
27V to 33V
output shut-off No automatic recovery
110 to 160%
drooping characteristic Automatic recovery
Allowable power supply terminal blocks 3
points to dedicated power supply (M3 screws)
Communication section and power supply
section to CC-Link/LT system: CC-Link/LT
dedicated connector (4-pin) x 2
0.40
Description
Depending on connected model. Max. 28.8 VDC
5.0A *
Across all external terminals and ground terminal,
10M by 500VDC insulation resistance tester
Module power supply: terminal block
3 pins (M3 screws)
Communication line/module power supply:
CC-Link/LT dedicated connector (4p) compatible
with CC-Link/LT dedicated flat cable x 2
0.26
24G+24V
NL
183 184
Dedicated power supply/Power supply adapter
Dedicated power supply/Dedicated adapterProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
The voltage drop can be calculated as shown below.
For details, refer to the power supply adaptor (CL1PAD1) manual.
a. Using look up chert b. Using calculation formula
<Current consumption change at CC-Link/LT system power ON>
If the point is within the area enclosed by the curved line, the number of power
supply adapter can be one.
Using the lookup chart or calculation formula, a voltage drop value can be calculated easily. (Ambient temperature: 20˚C)
Max. distance:
Total currentconsumption
The station farthest from the power supply adapter
Total current consumption of all CC-Link/LT modules
Total current consumption of all connected I/O devices (sensors, etc.)
+
(Max. distance (m) + Constant: 11)Voltage drop
(V) = Constant: 0.06 <= 3.6V
(Max. distance (m) + Constant: 9)Voltage drop
(V) = Constant: 0.08 Total current consumption (A)
Total current consumption (A)
<= 3.6V
Max. output current of general power supply or less
Total starting current consumption of CC-Link/LT modules(See the table below.)
List of refer to CC-Link/LT modules and their starting currentsCurrent consumption (mA)
707070707070707070707070707070
Module typeMaster/Bridge modules
Screw terminal block type
Current consumption (mA)
703516570707070707070707070707070
Module type
Sensor connector type
MIL connector type
Cable type
Model nameCL2Y8-TP1S2CL2Y8-TPE1S2CL1X4-D1C3CL1Y4-T1C2CL2X8-D1C3VCL2Y8-TP1C2VCL2X16-D1C3VCL2Y16-TP1C2VCL2XY16-DTP1C5VCL2X16-D1M1VCL2Y16-TP1M1VCL2Y16-TPE1M1VCL1X2-D1D3SCL1Y2-T1D2SCL1XY2-DT1D5S
Specifications8-point terminal block 0.1A Tr source output8-point terminal block 0.1A Tr output4-point sensor connector 24VDC input4-point sensor connector 0.1A Tr output8-point sensor connector 24VDC input8-point sensor connector 0.1A Tr output16-point sensor connector 24VDC input16-point sensor connector 0.1A Tr output16-point terminal block 24VDC input/2A relay output16-point MIL connector 24VDC input16-point MIL connector 0.1A Tr output16-point MIL connector 0.1A Tr source output2-point cable type 24VDC input2-point cable type 0.1A Tr output16-point cable type 24VDC input/0.1A Tr output
Model nameQJ61CL12FX2N-64CL-MAJ65SBT-CLBCL1X4-D1B2CL1Y4-T1B2CL1Y4-R1B2CL1Y4-R1B1CL2X8-D1B2CL2Y8-TP1B2CL1XY4-DT1B2CL1XY4-DR1B2CL1XY8-DT1B2CL1XY8-DR1B2CL1X4-D1S2CL1Y4-T1S2CL2X8-D1S2
SpecificationsCC-Link/LT master module for Q seriesCC-Link/LT master module for FX seriesCC-Link - CC-Link/LT bridge module4-point terminal block 24VDC input4-point terminal block 0.1A Tr output4-point terminal block 2A relay output4-point terminal block 2A relay output8-point terminal block 24VDC input8-point terminal block 0.1A Tr output4-point terminal block 24VDC input/0.1A Tr output4-point terminal block 24VDC input/2A relay output8-point terminal block 24VDC input/0.1A Tr output8-point terminal block 24VDC input/2A relay output4-point terminal block 24VDC input4-point terminal block 0.1A Tr output8-point terminal block 24VDC input
Total current consumption of all I/O devices (sensors, etc.)
**
***
1) Current consumption calculation (see the expression on page 182) <= General-purpose power supply's rated output current3) Starting current calculation
Spring clamp terminalblock type
Spring clamp terminal block type
When using dedicated flat cables
When using various cables
As the module marked with an asterisk (*) in the table below supplies power to I/O devices, its value must be included in the current consumption of the CC-Link/LT system.
Simple calculation method
Voltage drop <= 3.6V
[General-purpose power supply voltage - voltage drop] >= 20.4V
Current consumption [A]
Max
. cab
le le
ngth
[m] 0.1
1
0.1 1 3 5
10
50100
560
To calculate the current capacity of a general power supply, use the value found by 1) Current consumption calculation as the rated current (steady state).Also, when the CC-Link/LT system is started (at power-on), the value found by 3) Starting current calculation given below should be within the maximum output current* of the general power supply.*On some general power supplies, the maximum output current may be indicated as a <peak output current> or <overcurrent (protective) function>. Refer to these values.
Current capacity calculation for general-purpose power supply
Calculation examples
4m
1m
2m
5m
0.5m
5m 10m 10m
0.2m4m
0.2m
3m
4m
4m
3m
0.2m
0.2m
Trunk line
Branch line
Max. distance
<System configuration example> (Using dedicated flat cables)
Master station28mA (QJ61CL12)
From the above 1) and 2), appropriate current and voltage can be supplied with one power supply adapter.
Station 1)100mA
Station 2)60mA
Station 3)80mA
Station 4)200mA
Station 5)60mA
Station 6)150mA
Station 7)250mA
Power supply adapter
General-purpose power supply
24VDC input
* In the above figure, the current consumption of each station includes that of each I/O device connected to the station.
Total current consumption for all I/O devices: 550mA
Branch line A
Branch line C
Branch line B
Branch line D
From the above calculations, select a general-purpose power supply whosemax. output current is 111% or more relative to the rated current of 1A.
2) Voltage drop calculationTo ensure stable system operation,
Since the minimum operating voltage of each module is 20.4V,
1) Current consumption calculation
2) Voltage drop calculation
Sum of current consumptions
28mA + 100mA + 60mA + 80mA + 200mA + 60mA + 150mA + 250mA
Max. distance: Station from power supply adaptor, station 7) on branch line D
Station 1)Master station Station 2) Station 3) Station 4) Station 5) Station 6) Station 7)
= 928mA 1A 5A
(35.5m + constant: 11) constant: 0.06 1A = 2.79V 3.6V
24V -- 2.79V = 21.21V 20.4V
0.5m + 4m + 5m + 5m + 10m + 4m + 4m + 3m = 35.5m
Power supply adaptor installation: Number of power supply adaptors
General-purpose power supply selection: General-purpose power supply's current capacity
3) Starting current calculationTotal starting current
Master station Remote I/O station Total current consumption of I/O devices
+ + =Starting current: 70mA 7 modules Starting current: 70mA 550mA 1110mA=1.11A
General-purpose power supply's rated current1) Calculated current consumption = 1A
Maximum output current of general power supplyMaster station
General-purpose power supply's power ON
3) Starting current calculation(Max. output current of general power supply or less)
1) Current consumption calculation(Rated current of general power supply)
185 186
Selecting a power supplyProduct Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
AccessoriesDedicated flat cable connector
Model name: CL9-CNF-18
Whenassembled
VCTF cables connector
Model name: CL9-CNR-23
Flexible cable connector
Model name: CL9-CNR-20
Model name: CL2TE-10SModel name: CL2TE-5
Holder
Model name: CL1-HLD (5 pcs/package)
Open sensor connector (e-CON)
Model name: ECN-******
Terminating resistor
Model name: CL9-TERM
Terminating resistor
Model name: CL9-RYVK
Dedicated flat cable
Model name: CL9-FL4-18
Dedicated flexible cable
Model name: CL9-MV4-075
Tool for spring clamp terminal block
Model name: KD-5339
Crimping tool for communication connector
Model name: L-TOON-N
Crimping tool for open sensor connector
Model name: e-TOOL-N
Common terminal blockScrew terminal block
Common terminal blockSpring clamp terminal block
If you have any inquiries, contact: MITSUBISHI ELECTRIC SYSTEM & SERVICE;CO.,LTD.
Common terminal block for remote I/O modules (screw terminals) / analog modulesApplicable model: CL2X8-D182, CL2Y8-TP1B2,
CL2AD4-BIncluded: 1 daisy chain cable with solderless
terminal (100mm)
Common terminal block for remote I/O modules (spring clamp terminal block)Applicable model: CL2X8-D1S2
Holder for remote I/O modules (cable types).
Connector designed specially for use in the CC-Link/LT system (10 pcs/package)This connector consists of 2 components.
Connector designed specially for use in the CC-Link/LT system (20 pcs/package)This connector consists of 2 components.
Connector designed specially for use in the CC-Link/LT system (20 pcs/package)This connector consists of 2 components.
I/O connector for sensor connector type only. *The model name varies depending on the connector color or cable diameter.
Terminating resistor for dedicated flat cable, VCTF cable, and flexible cable. (2 pcs/package)
Terminating resistor for dedicated flat cable (CL9-FL4-18). (2 pcs/package)
CC-Link/LT dedicated flat cableTo prevent incorrect cable insertion, the number of grooves is decreased by 1 on one side.
Highly flexible insulator (ETFE) and strand structure has realized excellent flexing performance of 4 million times* or more. *Measured under the specified conditions
Special tool used for cable connection to or disconnection from a spring clamp terminal.
Special tool used for crimping a cable to a communication connector.
Special tool used for connecting a cable to an open sensor connector (e-CON).
187 188
Optional productsOptionProduct Information
Other/
Softw
areE
mbedded
Technical
Information
Support
Rem
ote I/OA
nalogPow
er supply/Adapter
Option
Master
Bridge
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Brid
geR
emot
e I/O
Ana
log
Pow
er s
uppl
y/Ad
apte
rO
ptio
nM
aste
rE
mbe
dded
189
MemoMemoMemo
Other/SoftwareConfigurator for CC-Link (GX Confiturator-CC)
MELSEC Programming Software (GX Developer)
FX Series interface block
AC servo/interface modules
Inverters
Mitsubishi graphic operation terminal GOT series
CNC (Computerized Numerical Control)
Industrial robots
Breaker
Energy Measurement Module
Power measurement modules
Multi-circuit power measuring module [Eco Monitor II]
Protective relays
199
200
201
202
203
205
207
208
209
210
211
212
213
Technical InformationCC-Link specifications
T-Branch communication specification(When Repeater (T-Branch) Modules are not used)
CC-Link communication
CC-Link specifications
Differences between CC-Link Versions 2 and 1
CC-Link/LT specifications
CC-Link/LT network wiring specifications
Cable specifications
General specifications
Terminology list
Icon List
215
216
217
218
219
220
220
221
221
222
223
SupportMELFANSweb
CC-Link Partner Association (CLPA)
Global support system
Warranty
225
226
227
230
Embedded ModulesEmbedded I/O modules
CC-Link Ver.2 Embedded type interface board
Object development
Communication LSI dedicated
191
195
196
197
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
190
Overview
Names and settings of each part
Cascade connection method
Features
Embedded
Circuit board mounting example
PW L RUN
402010STATION NO. B RATE
8 4 2 1 4 2 1
L ERR. X0 X1 X2 X3 X4J65MBTL1N-16DT
X5 X6A
X7
Y8
INPUT / OUTPUT UNIT
JAPAN
DATE
ON Y9 YA YB YC YD YE YF
LED display
PWL RUN
L ERR
XO to XF/XO to X1FYO to YF/YO to Y1F
LED name Description
Transmission rate setting switch
Station No. setting switch
Turns on when power supply of CC-Link embedded I/O module is turned on.Checks if the input module is communicating with the master station of CC-Link embedded I/O adapter normally.Turns on when normal data is received from master station, and turns off when time has expired.ON: When communication data errors (CRC error) occur, and when the station No. setting or data link transmission speed setting violates the setting switch range.Flashing at regular intervals:Indicates that the station number setting or transmission speed setting switch position was changed while power is on.Flashing at irregular intervals:Indicates that the terminal resistor is left unconnected or that the CC-Link embedded I/O adapter or CC-Link dedicated cable is affected by noise.Indicates the input/output ON/OFF status. Indicator is ON when the input is ON, and is OFF when the input is OFF.Set the 10s place using “10”, “20”
and/or “40” of STATION NO.Set the 1s place using “1”, ”2”, “4” and/or “8” of STATION NO.
01234
156kbps625kbps2.5Mbps5Mbps10Mbps
Pin No. Signal name
OE-INOE-IN
SD-IN
RD
OE-OUT
SD-OUT
SD-IN
RD
(OPEN)
A29
A28
B27
A29
A28
A27
RDGON GND
A26
B27
B28
A30
A31
B30
B31 DA
DB
DG
FG
OE-OUT
SD-OUT
DADA
DB
DG
SLD
FG
DB
DG
FG
B29
B28
A30
A31
B30
B31
B29
A27 A26
RDGON GND
CC-Link embeddedI/O module (2)
CC-Link embeddedI/O module (1)
* Reserve at least 5mm between I/O modules.
OE-INOE-IN
SD-IN
RD
OE-OUT
SD-OUT
SD-IN
RD
(OPEN)
A20
A19
B18
A20
A19
A18RDGON GND
A17
B18
B19
A21
A22
B21
B22 DA
DB
DG
FG
OE-OUT
SD-OUT
DADA
DB
DG
SLD
FG
DB
DG
FG
B20
B19
A21
A22
B21
B22
B20
A18 A17
CC-Link embeddedI/O module (2)
CC-Link embeddedI/O module (1)
RDGON GND
* The shapes of actual modules may differ somewhat from the shapes depicted in these photographs.
Mounting this product to your circuit board allows easy development of remote I/O stations.
AJ65MBTL1N-M
AJ65MBTL1N-16DAJ65MBTL1N-16T
AJ65MBTL1N-32DAJ65MBTL1N-32T
AJ65MBTL1N-16DT
191
Embedded ModulesEmbedded I/O modules
Other/
Softw
areE
mbedded
Technical
Information
Support
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
External wiring method
Input module
AJ65MBTL1N-16D
Unit: mm
7.5
D=
22H
=31
.5
3.5
W=53
5.5 5.5
2±0.
052±0.0542±0.1
A22 A01
B01B22
PW L RUN
402010STATION NO. B RATE
8 4 2 1 4 2 1
L ERR. X0 X1 X2 X3 X4J65MBTL1N-16D
X5 X6A
X7
X8
INPUT / OUTPUT UNIT
JAPAN
DATE
ON X9 XA XB XC XD XE XF
B22A22B21A21B20A20B19A19B18A18B17A17B16A16B15A15B14A14B13A13B12A12B11A11B10A10B09A09B08A08B07A07B06A06B05A05B04A04B0322000pF
630V A03B02A02B01A01
DA
AJ65MBTL1N-16DPin No.
*2
Module powersupply
*1
Insulation
DADBDGSLD
Signal name Circuit board Signal name
Vacant
VacantVacantVacantVacant
VacantVacantVacantVacantVacantVacant
DBDGFG
OE-OUTOE-INSD-OUTSD-IN
RDRDGON
GND
X0X1X2X3X4X5X6X7X8X9XAXBXCXDXEXF
COMCOM
+24VDC DC+24V
+24V
24G
FG
24G24G
X0X1X2X3X4X5X6X7X8X9XAXBXCXDXEXF
24VDCCOM
R
Internal circuit
R
RR
*1: Add the circuit for noise reduction capability. *2: Connect A17 and A18 without fail if cascade connection is not made.
Input specifications
Number of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
External wiring method
Input module
AJ65MBTL1N-32D
Unit: mm
*1: Add the circuit for noise reduction capability. *2: Connect A17 and A18 without fail if cascade connection is not made.*3: Connect A28 and A27 without fail if cascade connection is not made.
A14
B13A13B12A12B11A11B10A10B09A09B08A08B07A07B06A06
B05A05B04A04B03
A03B02A02
X13
X14X15X16X17X18X19X1AX1BX1CX1DX1EX1FCOMCOM
+24V+24V
X13
X14X15X16
X17X18
X19X1AX1B
X1CX1D
X1EX1F
24VDC
COM
VacantVacantVacantVacantVacantVacant
Insulation
DC DC
A15B14
X11X12
X11
X12
A17B16A16B15
B31A31B30A30B29A29B28A28B27A27B26A26B25A25
B24A24B23
A23B22
*3
*1
DA
AJ65MBTL1N-32D
DADBDGSLD
Circuit board
DBDGFG
OE-OUTOE-IN
SD-OUTSD-IN
RD
RDGON
GND
X0
X1X2
RX0X1X2
R
RR
Signal name Signal namePin No.
Vacant
VacantVacantVacantVacant
A22B21A21
B20A20B19A19B18
A18B17
X3X4X5
X6X7X8X9XA
XBXC
X3X4X5X6X7X8X9XAXBXC
XDXEXFX10
XDXEXF
X10
COM
+24V
24G
FG
22000pF630V
Module powersupply
B01A01
24G24G
VacantVacant
Internal circuit
[Recommended circuit board dimensions](top view)
[Recommended circuit board dimensions](top view)
H=
31.5
3.5
D=
22
W=85
7.55.5 19.5
2±0.
052±0.0560±0.1
A31 A01
B01B31
DC input
pts16
DC input
pts32
24VDCInput Embedded
24VDCInput Embedded
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
0.95±0.04
0.95±0.04
OFF ON
ON OFF
Voltage
Current
Description
16 points
Photocoupler
24VDC
Approx. 4mA
19.2 to 26.4VDC (ripple ratio: within 5%)
50%
18VAC/3.5mA or higher
6VAC/1.7mA or lower
5.1k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common
1 station 32 points assignment (use 16 points)
20.4 to 26.4VDC (ripple rate: within 5%)
35mA or lower (When TYP.24VDC)
DC type noise voltage 500Vp-p, noise
width 1µs, noise carrier frequency 25 to
60Hz (noise simulator condition)
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals and ground,
10 M or higher by insulation resistance tester
0.03
44-pin, 2-row, 2mm-pitch pin header
Description
16 points
Photocoupler
24VDC
Approx. 4mA
19.2 to 26.4VDC (ripple ratio: within 5%)
50%
18VAC/3.5mA or higher
6VAC/1.7mA or lower
5.1k
1.5ms or less (at 24VDC)
1.5ms or less (at 24VDC)
Positive common (Sink type)
16 points/common
1 station 32 points assignment (use 16 points)
20.4 to 26.4VDC (ripple rate: within 5%)
35mA or lower (When TYP.24VDC)
DC type noise voltage 500Vp-p, noise
width 1µs, noise carrier frequency 25 to
60Hz (noise simulator condition)
500VAC across all DC external terminals
and ground for 1min
500VDC across all DC external terminals and ground,
10 M or higher by insulation resistance tester
0.03
62-pin, 2-row, 2mm-pitch pin header
192
Embedded
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Input specifications
Nunmber of input points
Isolation method
Rated input voltage
Rated input current
Operating voltage range
Max. Input derating
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response
time
Input form
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
External wiring method
I/O module
AJ65MBTL1N-16DT
Unit: mm
Embedded
7.5
D=
22H
=31
.5
3.5
W=53
5.5 5.5
2±0.
052±0.0542±0.1
A22 A01
B01B22
PW L RUN
402010STATION NO. B RATE
8 4 2 1 4 2 1
L ERR. X0 X1 X2 X3 X4J65MBTL1N-16DT
X5 X6A
X7
Y8
INPUT / OUTPUT UNIT
JAPAN
DATE
ON Y9 YA YB YC YD YE YF
*1: Add the circuit for noise reduction capability. *2: Connect A17 and A18 without fail if cascade connection is not made.
[Recommended circuit board dimensions](top view)
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
External wiring method
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Wiring method for common
No. of stations occupied
I/O module
power supply
Noise immunity
Withstand voltage
Insulation resistance
Weight (kg)
External wiring method
Output module
AJ65MBTL1N-16T
Unit: mm
Output specifications
Number of output points
Isolation method
Rated load voltage
Operating load voltage range
Max. load current
Max. inrush current
Leakage current at OFF
Max. voltage drop at ON
Output form
Protective function
Response
time
Output area
external
power supply
Surge suppression
Description
8 points
Photocoupler
24VDC
20.4 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 0.8A/common
0.7A 10ms or less
0.1mA or lower
0.1V or less (TYP) 0.1A,
0.2V or less (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
1ms or lower
1ms or lower (rated load, resistive load)
19.2 to 26.4VDC (ripple ratio: within 5%)
5mA or lower (when 24VDC and all point is on)
Not including external load current
Zener diode
Embedded
7.5
D=
22H
=31
.5
3.5
W=53
5.5 5.5
2±0.
052±0.0542±0.1
A22 A01
B01B22
PW L RUN
402010STATION NO. B RATE
8 4 2 1 4 2 1
L ERR. Y0 Y1 Y2 Y3 Y4J65MBTL1N-16T
Y5 Y6A
Y7
Y8
INPUT / OUTPUT UNIT
JAPAN
DATE
ON Y9 YA YB YC YD YE YF
*1: Add the circuit for noise reduction capability. *2: Connect A17 and A18 without fail if cascade connection is not made.
Output module
AJ65MBTL1N-32T
Unit: mm
*1: Add the circuit for noise reduction capability. *2: Connect A26 and A27 without fail if cascade connection is not made.
[Recommended circuit board dimensions](top view)
[Recommended circuit board dimensions](top view)
H=
31.5
3.5
D=
22
W=85
7.55.5 19.5
2±0.
052±0.0560±0.1
A31 A01
B01B31
Embedded
Embedded I/O modules
B22A22B21A21B20A20B19A19B18A18B17A17B16A16B15A15B14A14B13A13B12A12B11A11B10A10B09A09B08A08B07A07B06A06B05A05B04A04B0322000pF
630V A03B02A02B01A01
DA
AJ65MBTL1N-16TPin no.
*2
Module powersupply
*1
Insulation
DADBDGSLD
Signal name Circuit board Signal name
Vacant
VacantVacantVacantVacant
VacantVacantVacantVacant
DBDGFG
OE-OUTOE-IN
SD-OUTSD-IN
RDRDGON
GND
Y0Y1Y2Y3Y4Y5Y6Y7Y8Y9YAYBYCYDYEYF
CTL+CTL+COM-COM-
+24VDC DC+24V
+24V
24G
FG
24G24G
Y0L
Y1Y2Y3Y4Y5Y6Y7Y8Y9YAYBYCYDYEYF24VDC
CTL+COM-
L
Constant V.circuit
Internal circuit
A14B13A13B12A12B11A11B10A10B09A09B08A08B07A07B06A06B05A05B04A04B03A03B02A02
Insulation
Y13Y14Y15Y16Y17Y18Y19Y1AY1BY1CY1DY1EY1F
CTL+CTL+
DC DC
Y13Y14Y15Y16Y17Y18Y19Y1AY1BY1CY1DY1EY1F
CTL+
COM-
VacantVacant
A15B14
Y11Y12
Y11Y12
A17B16A16B15
B31A31B30A30B29A29B28A28B27A27B26A26B25A25B24A24B23A23B22
*2
*1
DA
AJ65MBTL1N-32T
DADBDGSLD
Circuit board
DBDGFG
OE-OUTOE-INSD-OUTSD-IN
RDRDGON
GND
Y0Y1Y2
Y0Y1Y2
Signal name Signal namePin no.
Vacant
VacantVacantVacantVacant
A22B21A21B20A20B19A19B18A18B17
Y3Y4Y5Y6Y7Y8Y9YAYBYC
Y3Y4Y5Y6Y7Y8Y9YAYBYC
YDYEYFY10
YDYEYFY10
CTL+
22000pF630V
12/24VDCL
L
COM-COM-COM-COM-
COM-COM-COM-
Constant V.circuit
+24V
24G
FG
Module powersupply
B01A01
24G24G
+24V+24V
VacantVacant
Internal circuit
24VDCInput
B22A22B21A21B20A20B19A19B18A18B17A17B16A16B15A15B14A14B13A13B12A12B11A11B10A10B09A09B08A08B07A07B06A06B05A05B04A04B0322000pF
630V A03B02A02B01A01
DA
AJ65MBTL1N-16DTPin no.
*2
Module powersupply
*1
Insulation
DADBDGSLD
Signal name Circuit board Signal name
Vacant
VacantVacantVacantVacant
VacantVacantVacantVacant
DBDGFG
OE-OUTOE-IN
SD-OUTSD-IN
RDRDGON
GND
X0X1X2X3X4X5X6
R
R
X7Y8Y9YAYBYCYDYEYF
DC24VDC24VDC24GDC24G
+24VDC DC+24V
+24V
24G
FG
24G24G
X0X1X2X3X4X5X6X7Y8Y9YAYBYCYDYEYF
L
L
24VDCDC24VDC24G
R
R
Internal circuit
Constant V.circuit
0.1AOutput L.current
J65MBTL1N-32TAY0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF
Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F
Transistoroutput
pts16 Protection
Embedded
0.1AOutput L.current
Transistoroutput
pts32 Protection
Embedded
0.1AOutput L.current
Transistoroutput
pts8 ProtectionDC input
pts8External dimensions & terminal layoutExternal connection diagram
Detailed specifications
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
0.95±0.04
0.95±0.04
0.95±0.04
OFF ON
ON OFF
Voltage
Current
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Voltage
Current
External dimensions & terminal layoutExternal connection diagram
Detailed specifications
OFF ON
ON OFF
Voltage
Current
OFF ON
ON OFF
Voltage
Current
Description
16 points
Photocoupler
12/24VDC
20.4 to 26.4VDC (ripple ratio: within 5%)
0.1A/point, 1.6A/common
0.7A 10ms or less
0.1mA or lower
0.1V or lower (TYP) 0.1A,
0.2V or lower (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
1ms or less
1ms or less (rated load, resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
10mA or less (at 24VDC and all point is on)
Not including external load current
Zener diode
16 points/common
1 station 32 points assignment (use 16 points)
20.4 to 26.4VDC (ripple ratio: within 5%)
50mA or lower (When TYP.24VDC)
Noise voltage 500Vp-p, noise carrier frequency
25 to 60Hz (noise simulator condition)
500VAC across all DC external
terminals and ground for 1min
500VDC across all DC external terminals and ground,
10 M or higher by insulation resistance tester
0.03
44-pin, 2-row, 2mm-pitch pin header
Description
32 points
Photocoupler
12/24VDC
10.2 to 26.4VDC (ripple ratio: within 5%)
0.1 A/point, 3.2A/common
0.7A 10ms or lower
0.1mA or lower
0.1V or lower (TYP) 0.1A,
0.2V or lower (MAX) 0.1A
Sink type
Overload protection, overvoltage
protection, overheat protection
1ms or less
1ms or less (rated load, resistive load)
10.2 to 26.4VDC (ripple ratio: within 5%)
15mA or less (at 24VDC and all point is on)
Not including external load current
Zener diode
32 points/common
1 station 32 points assignment (use 32 points)
20.4 to 26.4VDC (ripple ratio: within 5%)
60mA or less (at TYP.24VDC)
Noise voltage 500Vp-p, noise carrier frequency
25 to 60Hz (noise simulator condition)
500VAC across all DC external
terminals and ground for 1min
500VDC across all DC external terminals and ground,
10 M or higher by insulation resistance tester
0.04
62-pin, 2-row, 2mm-pitch pin header
Description
8 points
Photocoupler
24VDC
Approx. 7mA
19.2 to 26.4VDC (ripple ratio: within 5%)
50%
14VAC/3.5mA or higher
6 VAC/1.7mA or lower
Approx. 3.3k
1.5ms or less (at 24VDC)
1.5ms or less (ay 24VDC)
Positive common (sink type)
16 points/common
1 station 32 points assignment (use 16 points)
19.2 to 26.4VDC (ripple rate: within 5%)
50mA or less (at TYP.24VDC)
Noise voltage 500Vp-p, noise width 1µs, noise carrier
frequency 25 to 60Hz (noise simulator condition)
500VAC across all DC external
terminals and ground for 1 min
500VDC across all DC external terminals and ground,
10 M or higher by insulation resistance tester
0.03
44-pin, 2-row, 2mm-pitch pin header
194
Embedded
193
Other/
Softw
areE
mbed ded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
CC-Link Ver.2 embedded type interface board
Embedded
Embedded modules
Features
Q50BD-CCV2
Bus, CPU
Internal memory
Communication sectionDisplaySwitchCurrent consumptionCircuit board dimensions (mm)Weight (kg)
Bus I/F
CPU
ROM
SRAM
Communication chip
SpecificationsGeneral bus I/F
SH3(HD6417708RF60A)QFP 144pin
ROM 512Kword x 16bit (8Mbit)Dual port RAM 32Kword x 16bit (512Kbit)
Work RAM 256Kword x 16bit (4Mbit)MFP1
6 LEDs: Green (RUN, L RUN, SD, RD) Red (ERR., L ERR.)Station no. setting switch, transmission rate setting switch, mode setting switch, select switch
0.32A70.0 x 80.0
0.03
ItemClassification
Easy to develop master stations, standby master stations, local stations, and intelligent device stations. These station functions can be obtained simply by installing an interface board at the user board.
Supports CC-Link Ver.2 With CC-Link Ver.2, the number of cyclic points can be expanded to a maximum of 8192 points for RX/RY, and 2048 words for RWr/RWw per network. Moreover, there is full backward compatibility with the previous version (Ver.1).
Space-saving design
Compact dimensions of 70mm x 80mm.
A general-purpose bus interface offers easy communication with the user board. The interface between the user board and interface board handles general type memory control signals (address bus, data bus, read/write, etc.) making communication with the user board easy.
Basic specifications
Object development
Features
MFP1NDevice kit
MFP: Mitsubishi Field-network ProcessorFor MFP1, a separate license agreement is required. For the development of CC-Link products that use MFP, "Open Field Network CC-Link, CC-Link/LT Compatible Product Development Guidebook (L(NA)-08052E-A)" is available.For details or lead-free/RoHS compatible products, contact the Open System Center.
Order model name
Application
Package unit
LSI external shape
Item MFP1N
Master station / local station / intelligent device station
100-pin QFP (Quad FLAT Package)
20 x 14mm body, 0.65mm between pins
A6GA-CCMFP1NN300F
300pcs
A6GA-CCMFP1NN60F
60pcs
Device kit
Q6KT-NPC2OG51
Network circuit
40pcs
-
List of models
Easy to develop master stations, standby master stations, local stations, and intelligent device stations by using the CC-Link Ver.2 compatible product development tool with object software.
Supports CC-Link Ver.2.With CC-Link Ver.2 compatibility, the number of cyclic points can be expanded to a maximum of 8192 points for RX/RY, and 2048 words for RWr/RWw per network.Moreover, there is full backward compatibility with the previous specifications (Ver.1.10).
Easy data communicationUse of dual port RAM enables easy data communication between the network circuit and user application circuit.
Object code installation method is selectable. Object code installation is required for Ver.2 compatible products.As a transmission tool for serial communication, use the "HyperTerminal" function provided in Windows 2000 or Windows XP.
The CC-Link Ver.2 compatible product development tool with object software is composed of the object code (SW1D5C-CCV2OBJ) and a network circuit.The network circuit is made up using a device kit (Q6KT-NPC20G51).
196
Embedded
195
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Embedded
Embedded modules
Communication LSI dedicated
Features
MFP2NMFP2ANMFP3N
Features
CLC13CLC21CLC31
Order model nameApplicationPackage unit
LSI external shape
Item MFP2NMFP2ANA6GA-CCMFP2N 60F
Remote I/O station
100-pin QFP (Quad FLAT Package)
14 x14mm body, 0.5mm between pins
80-pin QFP (Quad FLAT Package)
12 x 12mm body, 0.5mm between pins
A6GA-CCMFP2N 300F
60pcs 300pcs
A6GA-CCMFP3N 60F
Remove device station
A6GA-CCMFP3N 300F
60pcs 300pcs
A6GA-CCMFP2AN 60F
Remote I/O station
A6GA-CCMFP2AN 300F
60pcs 300pcs
MFP3N
MFP: Mitsubishi Field-network ProcessorFor the development of CC-Link products that use MFP, "Open Field Network CC-Link, CC-Link/LT Compatible Product Development Guidebook (L(NA)-08052E-A)" is available.For details or lead-free/RoHS compatible products, contact the Open System Center.
Order model nameApplicationPackage unit
Product NameCL2GA21-60
300pcs
CL2GA21-60
60pcs
CLC21
Remote master station
80-pin QFP (Quad FLAT Package)
12 x12mm body, 0.5mm between pins
CLC13
CL2GA13-60
Master station
60pcs
100-pin QFP (Quad FLAT Package)
14 x14mm body, 0.5mm between pins
CLC31
CL2GA31-60
Remote device station
60pcs
80-pin QFP (Quad FLAT Package)
12 x12mm body, 0.5mm between pinsCLC: CC-Link/LT Controller
LSI external shape
CC-Link compatible devices can be developed easily without worrying about the communication protocol. Also the CC-Link communication protocol is built-in.
MFP2N /MFP2AN (for remote I/O stations)Devices that handle bit information (digital input/output) can be developed easily without a CPU.MFP2N can control max. 32 points and MFP2A can control max. 16 points.MFP3N (for remote device stations)Simply access to an external CPU via the two port RAM. Devices that handle bit information (digital input/output) and word information (remote register) can be developed easily without concern for communication protocol.
List of models
CC-Link compatible devices can be developed easily without worrying about the communication protocol. Also the CC-Link communication protocol is built-in.
CLC13 (for master stations)An internal communication protocol makes it easy (by memory reading from an external CPU) to develop devices for data communication and remote station control without worrying about the communication protocol.CLC21 (for remote I/O stations)An internal communication protocol makes it easy to develop devices for handling bit data without using an external CPU (programless).CLC31 (for remote device stations)Communication LSI for CC-Link/LT remote devices.
List of models
Embedded modulesEmbedded
(L(NA)-08052E)
When developing CC-Link and CC-Link/LT compatible products using development tools (such as embedded type interface board, object development, communication LSI dedicated) offered by Mitsubishi Electric Corporation, "Open Field Network CC-Link, CC-Link/LT Compatible Product Development Guidebook", which describes more details of development tools, is available.
MemoMemoMemo
The Open System Center provides development support for embedded modules.Admission (regular member, executive member or board member) into the CC-Link Partner Association (CLPA) is required in order to purchase embedded modules.(For details of CLPA, refer to page 226.)
Contact info for inquiries:CC-Link Partner Association (Japan)TEL: +81-52-919-1588 FAX: +81-52-916-8655
Open Field Network CC-Link, CC-Link/LT Compatible Product Development Guidebook
198
Embedded
197
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Configurator for CC-LinkGX Configurator-CC
Features
Features
OS
CPUDisplayMemoryRequired free hard disk spaceDisk driveCommunicationinterface
Item
GX Configurator-CCDescription Related manual, etc.Product name
MELSEC Programming SoftwareGX Developer
*1 Pentium 150MHz or faster processor is recommended to use Windows® Millennium Edition.
*2 64MB or more memory is recommended to use Windows® 2000 Professional.
Software package for parameter setting of the CC-Link master module as well as parameter setting, line test, and monitoring of remote device stations
Operating manual SH-080103Mitsubishi Integrated FA Software Catalog L(NA)08008
OS
CPUDisplayMemoryRequired free hard disk spaceDisk driveCommunicationinterface
Item
GX DeveloperDescription Related manual, etc.Product name
*1 Pentium 150MHz or faster processor is recommended to use Windows® Millennium Edition.
*2 64MB or more memory is recommended to use Windows® 2000 Professional.
*3 For Windows® XP: 128MB
*4 Ver. 2 mode is supported by Ver. 8.03D or later.
*5 Parameters can be set with GX Developer not supporting Ver. 2 if they are entered
with sequence programs.
MELSEC PLC programming software package Operating manual SH-080373EMitsubishi Integrated FA Software Catalog L(NA)08008
Software/Other
Precaution FX PLCs cannot be used. The master station parameters for the Q and QnA Series PLC CPUs must be set by GX Developer.
<Sequence program when GX Configurator-CC is used>
Set parameters on GX Configurator-CCand write them to E2PROM.
<Conventional sequence program>
Xn7
Xn6
SET Yn0
SET Yn6
Xn9
Xn8
SET Yn0
SET Yn8
You can makeparameter setting onGX Configurator-CC!
Parameter setting programis not necessary.Yn6 is changed to Yn8 sincedata link start is made withE2PROM parameter.
It is possible to set parameters directly in Windows without having to create a sequence program.
Master parameter setting is available for A series master modules.
Parameters of remote device stations connected to a QnA or A series master module can be uploaded or
downloaded, and monitoring and tests are also executable.
Via an A series master module, buffer memory setting is available for the AJ65BT-R2.
Enriched diagnostic function is provided.
Operating environment
List of models
CC-Link parameter setting can be done with GX Developer alone.Ver. 2 mode parameters can be entered simply.
The parameter setting function "Network Parameter (CC-Link)" of GX Developer allows the setting of parameters
without a sequence program for QCPU (Q mode) and QnA PLC CPUs.
Networks with Q, QnA and A PLC CPUs can be monitored with the "CC-Link Diagnostic function of GX Developer.
Operating environment
List of modelsModel name
SW D5C-GPPW
SW D5C-GPPW
Model nameSW D5C-J61P
SW D5C-J61P
Operating environmentWindows 95 (English version), Windows 98 (English version), Windows NT, Workstation 4.0 (English version),
Windows 2000 Professional (English version), Windows ME (English version)Pentium 133 MHz or more*1
Resolution: 800 x 600 or more (1024 x 768 are recommended.)32MB min.*2
120MB min.CD-ROM disc drive
RS-232C port: Necessary for communication with PLC CPU (Required for access to PLC CPU other than Q02H/Q06H/Q12H/Q25HCPU)USB port: Usable for communication with QCPU (Q mode) (Except for Q00J/Q00/Q01/Q02CPU and Remote I/O module)
Operating environmentWindows 95 (English version), Windows 98 (English version), Windows NT, Workstation 4.0 (English version), Windows 2000 Professional
(English version), Windows ME (English version), MS-Windows XP Professional*3, MS-Windows XP Home Edition*3
Pentium 133MHz or more*1
Resolution: 800 x 600 or more (1024 x 768 are recommended.)32MB min., for Windows 2000: 64MB min., for Windows XP: 128MB min.*2
150MB min.CD-ROM disc drive
RS-232C port: Necessary for communication with PLC CPU (Required for access to PLC CPU other than Q02H/Q06H/Q12H/Q25HCPU)USB port: Usable for communication with QCPU (Q mode) (Except for Q00J/Q00/Q01/Q02CPU and Remote I/O module)
199 200
Software
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
FX Series interface block
Features
FX2N-32CCL
No. of stations occupiedPower supply
Applicable PLC
No. of occupied I/O pointsExternal dimensions (mm)Weight (kg)
Specifications1 to 4 stations (set by the rotary switch) (remote device station)
5VDC 130mA (Supplied from a PLC)24VDC 50mA (Supplied from external power supply. PLC’s service power supply is usable.)
Mitsubishi micro-PLCsFX1N, FX2N series
FX1NC, FX2NC, FX3UC series (connector conversion module required)8 points for the FX PLC
43 (W) X 90 (H) X 87 (D)0.2
Item
AC servo amplifier / Interface module
Features
MR-J2S-MCP-S084MR-J2S-T01
Feeding method
Absolute position systemNo. of stations occupied
Point tablePosition data input*
Com
man
dm
etho
d
SpecificationsPositioning method
Up to 31 points√
(When occupying 2 stations)√
1 station/2 stations (remote device station)
Item
* The position data input method: The positioning data is transferred directly to the servo amplifier via CC-Link communication.
Note: A servo amplifier (MR-J2S-MCP-S084) and a CC-Link interface module (MR-J2S-T01) are necessary. Supply power (5VDC) from the servo amplifier to MR-J2S-T01.
Position data (feed rate)Speed data
This interface block is used to connect Mitsubishi Micro-PLCs of the FX1N, FX2N, FX1NC, FX2NC and FX3UC series to a CC-Link network as remote-device stations.
Introduction of a micro PLC realizes distributed control easily and cost effectively.
The maximum data of up to 112 bits and 16 words can be sent or received with the master station (when 4 stations are occupied).
Since the number of occupied stations can be selected (1 to 4), a system of a desired communication scale can be constructed.
No positioning controller may be needed because the servo amplifier has a built-in positioning function.
This servo has sophisticated functions such as high level real time auto tuning, machine resonance suppression filter, etc.
These models are suitable for high frequency positioning.
Transmission of positioning data, start/stop and monitoring are executable through a CC-Link network.
Servomotors ranging from 50W to 7kW are applicable.
A distributed control system with AC servos can be easily constructed.
Performance specifications
Performance specifications
201 202
OtherOther
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Features
FREQROL-F700
Catalog numberCapacity range
Output frequency rangeControl methodFrequency setting signal
Start torque
Acceleration/deceleration time settingAcceleration/deceleration patternProtection/alarm functionsAmbient temperatureNo. of stations occupied
Item Specifications
L (NA) 06040ENG0.75kW to 110kW (200V)0.75kW to 110kW (400V)
0.5 to 400HzV/F control, optimum excitation control, simple magnetic flux vector control
Input via CC-Link communication and/or operation panel, or parameter unit (optional)(Analog input: 0 to 5VDC, 0 to 10VDC, 0 to ±10VDC, 4 to 20mA)
120%: 3Hz(When simple magnetic flux vector control and slip compensation are set.)
0 to 3600s (Individual setting is allowed.)Switchable among linear, S-pattern type A, and S-pattern type B
Overcurrent shutdown, regenerative overvoltage, overload shutdown, output short-circuit, stall prevention, momentary power failure, etc.-10°C to + 50°C (no freezing allowed)
1 station (remote device station)Expanded cyclic settings of x1, x2, x4, x8 (selectable)
Inverters
Features
FREQROL-M500
Catalog number
Capacity range
Output frequency range
Control method
Frequency
setting signal
Start torque
Acceleration/
deceleration
time setting
Acceleration/
deceleration pattern
Protection/
alarm functions
Ambient temperature
No. of stations
occupied
FREQROL-E500
(200V class (CC-Link type), 400V class)
L-174-9-C3984
0.1kW to 7.5kW(200V)
0.4kW to 7.5kW(400V)
General-purpose magnetic-flux
vector control and V/F control
Input via CC-Link communication
or Parameter module (optional).
150%: At 1Hz
(When general-purpose flux vector
control and slip compensation are set)
0.01 to 3600s
(Individual setting is allowed.)
Item
0.2 to 400Hz
150%: At 0.5Hz
(in case of advanced magnetic
-flux vector control)
0 to 3600s
(Individual setting is allowed.)
Input via CC-Link communication, operation panel, or parameter
unit (optional) (Analog input: 0 to 5VDC, 0 to 10VDC,
0 to ±10VDC, 4 to 20mA)
Switchable among linear, S-pattern type A, and S-pattern type B
Overcurrent shutdown, regenerative overvoltage, overload shutdown,
output short-circuit, stall prevention, momentary power failure, etc.
-10°C to + 50°C (no freezing allowed)
1 station (remote device station)
FEQROL-V500/V500L
L (NA) 06037E
1.5kW to 55kW/75kW(200V)
1.5kW to 55kW/75kW to 250kW(400V)
0 to 3000r/min
Vector control and V/F control
Input via CC-Link communication
and/or panel, and parameter
module (option) (Analog input:
0 to 10VDC, 0 to ±10VDC)
150% 1r/min
(in case of vector control)
Switchable among linear,
S-pattern A, B and C
Overcurrent shutdown,
regenerative overvoltage,
overload shutdown, stall prevention
momentary power failure, etc.
FREQROL-C500
L (NA) 06034
0.1kW to 3.7kW(200V)
0.5 to 120Hz
V/F control
CC-Link communication,
RS-485 communication
and digital setting using
built-in PLC function
0.01 to 999s
(Individual setting is allowed.)
linear
Overcurrent shutdown,
regenerative overvoltage,
overload shutdown, overheat fin,
stall prevention, etc.
FEQROL-A500/A500L
L-174-8-C3377
0.4kW to 55kW/75kW, 90kW(200V)
0.4kW to 55kW/75kW to 450kW(400V)
Advanced magnetic-flux
vector control and V/F control
FEQROL-F500/F500L
L-174-9-C4223
0.75kW to 55kW/75kW to 110kW(200V)
0.75kW to 55kW/75kW to 530kW(400V)
0.5 to 120Hz
Optimum excitation control
and V/F control
FREQROL-E500series FR-E520-0.1KN to 7.5KN 9 models, FR-E540-0.4K to 7.5K 7 models, 16 models in total
FREQROL-A500series FR-A520-0.4K to 55K 15 models, FR-A540-0.4K to 55K 15 models, 30 models in totalFREQROL-A500Lseries FR-A520L-75K, 90K 2 models, FR-A540L-75K to 280K 7 models, 9 models in total
FREQROL-F500series FR-F520-0.75K to 55K 14 models, FR-F540-0.75 K to 55K 14 models, 28 models in totalFREQROL-F500Lseries FR-F520L-75K to 110K 3 models, FR-F540L-75K to 375K 9 models, 14 models in total
FREQROL-C500series FR-C520-0.1KN to 3.7KN 7 models
FREQROL-V500Series FR-V520-1.5K to 55K 13models FR-A540-1.5K to 55K 13 models 26models in totalFREQROL-V500Lseries FR-V520L-75K 1 models FR-A540L-75K to 250K 7models 8models in total
Using the optional unit, FR-A5NC allows connection to the CC-Link network. Up to 42 inverters can be connected.The operations of connected inverters can be stopped or monitored from the CC-Link master station, and parameter reading/writing is also available.Mitsubishi’s Soft-PWM control system suppresses noise to a minimum level.
These models are suitable for applications such as fans or pumps. The optimum excitation control system has realized the industry’s highest level of energy saving.Using the optional unit, FR-A5NC allows connection to the CC-Link network. Up to 42 inverters can be connected.The operations of connected inverters can be stopped or monitored from the CC-Link master station, and parameter reading/writing is also available.Mitsubishi’s Soft-PWM control system suppresses noise to a minimum level.
The PLC function built in this series inverter allows sequence control using the inverter only (without I/O options).The ladder sequence can be programmed with “GX Developer”.The built-in CC-Link function allows communication between the master station and inverter with one CC-Link cable only, reducing the number of cables.
Using the optional unit, FR-A5NC allows connection to the CC-Link network. Up to 42 inverters can be connected.The adaptive magnetic flux observer can reduce torque fluctuations caused by changes in motor temperature.Easy gain tuning function automatically adjusts the speed control gain and position loop gain.
Performance specifications
FREQROL-F700 seriesFR-F720-0.75K to 110K 17 modelsFR-F740-0.75K to 560K 29 models 46 models in total
Dedicated model for fan pumps, and successor to the F500 Series. Offers optimal excitation control (upgraded version), and reduced power consumption due to functions such as a energy-saving monitor monitor.
New functions include a life assessment function and an internal EMC filter, etc., making it more useful than ever.
CC-Link operation is possible by using the FR-A7NC inverter option. Up to 42 inverters can be connected.
Performance specifications
High torque output (150%) can be realized at low speed (1Hz).FR-E540- K can be connected to the CC-Link network when the optional unit, FR-A5NC is used. Up to 42 inverters can be connected.The operations of connected inverters can be stopped or monitored from the CC-Link master station, and parameter reading/writing is also available.
203 204
OtherOther
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Mitsubishi Graphic Operation Terminal GOT Series
Features
GOT-A900 seriesFeatures
Handy GOT
Features
GOT1000 series
Item A8GT-J61BT13
Station typeNo. of stations occupied
Monitor device
Connection terminal blockApplicable solderless terminalPower supply methodCurrent consumption
External dimensions (mm)Weight (kg)
Intelligent device stationSelectable from 1 station/4 stations
1 station (RX/RY: 30 points each, RWr/RWw: 4 words each)4 stations (RX/RY: 126 points each, RWr/RWw: 16 words each)
Writing from GOT: RX and RWw assigned to GOT(varies depending on the no. of occupied stations)
Reading to GOT: All points of RX/RY and RWw/RWr
All devices of PLCs of the master/local stations
-RAV1.25 - 3, RAV3 - 3.5 (compliant with JIS C 2805)
0.25A
0.21
A8GT-J61BT15
Remote device stationSelectable from 2 stations/4 stations
2 stations (RX/RY: 84 points each, RWr/RWw: 8 words each)4 stations (RX/RY: 128 points each, RWr/RWw: 16 words each)
Writing from GOT / reading to GOT: RX/RY and RWw/RWr assignedto GOT(varies depending on the no. of occupied stations)
-
8-point terminal block (M3 x 8 screws)RAV1.25 - 3, 1.25 - YS3, RAV1.25 - 3, V1.25 - YS3
0.1A
0.20
Monitoring by cyclic transmission
Monitoring by transient transmission
Supplied from GOT
(Included in the current consumption of the main body. Only the power consumption of A850GOT is added to the current consumption of the main body.)
149 (W) x 99 (H) x 34 (D)
A complete lineup offers a variety of sizes and functions.
The PLC ladder monitor function is built in.When a machine in a system has gone down, the error cause can be easily identified by the touch search function that enables search of coils and contacts only by touching the GOT screen.The servo amplifier and motion controller monitoring function allows setting of current values and parameters, and viewing of error history on the GOT screen.Integrated drawing software “GT Designer2” enables efficient screen creation.Connection to CC-Link networkThe A900 series GOT can be connected to a PLC via a CC-Link network by mounting a communication unit onto it.
With sophisticated basic performance, GOT1000 is a next generation standard.
Beautiful screens with 60,000 colors can be displayed.The processing speeds in “drawing”, “computing” and “communication” have been improved, realizing the response performance 4-times faster than before.The TrueType font supporting Unicode 2.1 has been adopted.Multiple languages all over the world can be displayed clearly.A USB interface is provided on the front.Data transmission is easy without opening the panel and operability can be improved.A function connecting the GOT1000 to a PLC via CC-Link is soon available.
Performance specifications (For GOT 900 series CC-Link connection module)
Enriched functions are portable! Compact display unit of 0.79g
Using as an operation terminal for your machineOperation switch names can be changed as desired.Even in a limited installation space where a general operation panel can be hardly installedThis GOT can be used in such a space only when it is necessary.Convenient for start-up, adjustment or setup changeTeaching operations can be set viewing from various directions.Using as a peripheral of a PLCThe program list display function and monitoring function allow easy program debugging.Connection to CC-Link networkBy using the CC-Link interface unit (F9GT-CCL), the handy GOT (F940GOT- BD-H, F950GOT- BD-M3-H) can be connected to a Q series PLC via a CC-Link network.
205 206
OtherOther
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Industrial robots
Features
RP, RV-A, RH-A, RV-T, RH/RC-G series<Controller>
Item CR2A-572 CR4-533CR1-571
Control method No. of control axesMain functions
No. of stations occupied
PTP control, CP control4 to 6 axes (Simulaneous control of 2 additional axes)
Joint interpolation, linear interpolation, 3-dimensional circular interpolation, palletizing, conditional branching, subroutine, multitask, adaptive acceleration/deceleration control, deflection correction, Cartesian compliance control, etc.
1 station to 4 stations [set by the DIP switch] (intelligent device station)
<Robot>
Micro robot RP Series Verticaliy articulated robot RV Series Horizontally articulated robot RH Series
Palletizing robot RV-T Series LCD glass substrate transfer robot RH/RC-G Series
* Our standard conditions
CNC (Computerized Numerical Control)
Features
MELDAS series
Item MELDAS C6
5
16/80
1/65
-
-
512/512
40/60032000 Step
Machining center family
Lathe family
Tape length (standard/max.)PLC/APLC memory capacity (max.)Station typesNo. of stations occupied
Max. no. of axes (NC axis + spindle + PLC axis)Peripheral axes (MR-J2-CT)Machine contacts (standard/max.)
Operation board I/F (DI/DO)Max. remote I/O (DI/DO)
DI
DO
12
-
FTL C6(L family)
7
MELDAS 64AS
*1) 64/512(RIO type)*1) 48/512(RIO type)
64/4864/48
(Total: 128/96)
-
40/60032000 steps
M64ASL
5
4
TORAMAN C6
(T family)
-
7
M64ASM
5
4
M64SL
7
4
M64SM
7
4
MELDAS C64
7
16/80
1/65
-
-
512/512
40/60032000 steps
Master station / Local station1 station to 4 stations
FTL C64(M family)
-
14
-
FTL C64(L family)
14
TORAMAN C6
(T family)
-
14
MELDAS 64S
*1) 64/512(RIO type)*1) 48/512(RIO type)
64/4864/48
(Total: 128/96)
-
40/512032000 steps
M65SL
14
4
M65SM
7
4
MELDAS 65S
*1) 64/256(RIO type)*1) 48/256(RIO type)
64/4864/48
(Total: 128/96)
-
40/512032000 steps
M66SL
14
4
M66SM
7
4
MELDAS 66S
*1) 64/512(RIO type)*1) 48/512(RIO type)
64/4864/48
(Total: 128/96)
-
40/512032000 steps
Con
trol
axi
sM
achi
ne in
terf
ace
Performance specifications
The reinforced network functionality enables various system configurations.This robot controller can be used with the robots shown below. (Please consult us for combinations.)Global CNC MELDAS 64AS/64S/65S/66S
The world highest-level hardware performance: The CPU performance has been upgraded more than previous M60 series with 64-bit CPU and PLC LSI.
Major 12 languages are supported.
Connection to various networks is available.
Introduction of this series model allows comfortable system development.
High-speed and high-accuracy machining has been thoroughly pursued.
Multiple axes and systems can be controlled.
CNC for machining line C6/C64The built-in 64-bit RISC has improved the basic performance and control functionality.
The time and cost for designing electrical circuits can be reduced by the enhanced built-in PLC.
The improved maintenance function has realized reduction in system downtime.
Connection to various networks is available.
Adoption of the 64-bit RISC processor allows high-speed and highly accurate locus control, realizing a variety of operations.
With the additional axis control function (optional), traveling axes and turntables can be controlled. (Up to 8 axes)
Using PC support software, operations such as program editing or monitoring are executable. (Optional)
Only by installing a CC-Link card into the option slot, this controller can communicate with the master station via CC-Link.
Use of the dedicated programming language (MELFA-BASIC IV) makes access to devices on the CC-Link network easy.
Performance specifications
These robots are compatible with the controllers specified above. (Contact us for combinations.)
Small size, high speed and high accuracy are realized.
Max. load: 1kg to 5kgArm length: 236mm to 453mmCycle time: 0.28 sec *
Processing is available from various angles.
Max. load: 1kg to 20kgArm length: 418mm to 1561mmOil mist proof type, applicable to clean-room environment [special specifications]5-axis model, 6-axis model
This series is suitable for high-speed and high-precision operation.
Max. load: 5kg to 15kgArm length: 350mm to 850mmOil mist proof type, applicable to clean-room environment [special specifications]Cycle time: 0.46 sec *
High-speed palletizing robot suitable for material handling
Max. load: 100kg to 150kgArm length: 2360mm to 2730mmProcessing capacity: Max. 1600 cycles/hour *
High-speed large glass substrate transfer robotVarious axis structures are available in cylindrical, scalar and double-arm types.
This series is applicable to various substrate sizes and layouts.
Deflection correction function allows high-speed and high-precision transfer.
207 208
OtherOther
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Breaker
Features
MDU Breaker
Measured values
No. of stations occupied
SpecificationLoad current (current value, demand value, and max. demand value)
Line voltage (current value, demand value, and maximum demand value)Electric power (current value, demand value, and max. demand value)
Electric energy (integration value, hourly electric energy, and max. value of hourly electric energy)Leakage current (current value, demand value, and max. demand value)
Power factor (current value)1 station (remote device station)
Item
A breaker with a display functionSpace-saving breaker with built-in VT (Voltage Transformer) and CT (Current Transformer)
A display function has been added to the previous low-voltage breaker
Measurement and display of load current, line voltage, electric power, harmonic current, leakage current and power factor allows check of consuming energy, supporting energy saving activities.
Since the VT and CT are built in the unit, installation space can be saved.High cost-performance can be achieved for new and renewed applications.
A wide range from rated 50A (225A frame) to 800A (800A frame) can be supported, which makes this breaker suitable for various applications.
Models compatible with CC-Link, B/NET and pulse transmission are available, allowing flexible transmission of measured data.
Performance specifications
Energy Measurement Module
Features
EMU2-HM1-C EMU2-RD1-C EMU2-RD3-CEMU2-RD5-C EMU2-RD7-CEMU2-RD2-C-4WEMU2-RD4-C-4W
Phase/wire typeApplicable circuitNo. of circuits measuredRated voltage
Rated current
Measured valuesCC-Link communication
EMU2-HM1-C
Low-voltage only
110/220V shared (for single phase 2-wire
and 3 phase 3-wire) 100/200V
(for single phase 3-wire)
1 circuit
EMU2-RD1-C EMU2-RD3-CSingle phase 2-wire / single phase 3-wire / 3 phase 3-wire
3 circuits
110/220V (for single phase 2-wire and 3 phase 3-wire) 100/200V (for single phase 3-wire)
EMU2-RD5-C
5 circuits
50A, 100A, 250A, 400A, 600A (for a separate type current sensor)5A (for a separate type 5A current sensor)
Electric energy, current, current demand, voltage, electric power, electric power demand, and powe factor
No. of stations occupied: One station (remote device station) Version: Ver.1.10
EMU2-RD7-C
7 circuits
High/Low-voltage
Reactive power energy, reactive power, frequency, harmonic current, and harmonic voltage
EMU2-RD2-C-4W
2 circuits
EMU2-RD4-C-4W
4 circuits
Single phase 4-wire
63.5/110V, 110/190V, 120/208V, 220/380V, 240/415V
Item
Performance specifications
Streamlined system configuration is available with different types of modules for 1, 3, 5 and 7 circuits provided. (3-phase 4-wire is for 2 and 4 circuits)
Modules for both low-voltage only and high/low-voltage are availabe, allowing configuration of incoming circuit (high-voltage) and distribution circuit (low-voltage) in one module.
The existing CT wiring can be used without rewiring the system with the support of a separate type 5A current sensor.
209 210
OtherOther
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Multi-Circuit Power Measuring Module[Eco Monitor II]
Features
EMU-C7P4-6-A
Measured values
No. of occupied stations
SpecificationsLoad current (current value, demand value, and max. demand value)Line voltage (current value, demand value, and max. demand value)
Electric power (current value, demand value, and max. demand value)Electric energy (integration value, haurly electric energy, and max. value of hourly electric energy)
Leakage current (current value, demand value, and max. demand value)Power factor (current value)
1 station (remote device station)
Item
Current, voltage, electric power and energy values of multiple low-voltage circuits can be measured at the same time. Also, because single module can store, display and transfer measured data, installation space and steps can be saved.
Pulse inputs of up to 4 circuits allow production count for management based on energy consumption rate, or measurement of energy other than electric power, such as steam flow or gas flow.
By collecting and handling data via networks (CC-Link, B/NET and/or LONWORKS), energy-saving system can be managed. When data are stored in this stand-alone module, they can be analyzed and used for energy saving control. Adding some cassette-type network communication modules enables various kinds of system expansions depending on your budget.
Performance specifications
Measurement of multiple circuits (6 in 3-phase 3-wire case) is available with one Eco Monitor II
Power Measurement Module
Features
EMU-C3P5EMU-C33P5-5AEasily installed to existing circuit!Applicable to many kinds of applications
Phase/wire typeRated voltageRated currentMeasured values
No. of stations occupied
Item EMU-C3P5
250A / 100A / 50A (selectable)
EMU-C3P5-5A
5A (current on the primary side current sensor)
Single phase 2-wire / single phase 3-wire / 3-phase 3-wire (selected by the setting switch)110/220V (selected by the setting switch)
Current (each phase, total, demand, and max. demand value)Voltage (each phase, total, and max. value)
Electric power (current, demand, and max. demand value)Electric energy (integration value, hourly integration value, and max. value of hourly electric energy)
Leakage current (current value, demand value, and max. demand value)Time of max. value detection
1 station (remote device station)
In combination with a separate type current sensor (50A, 100A, 250A), this module can be easily installed to the existing circuit.Measurement is available in many items (current, voltage, electric power, electric energy, leakage current, time of max. value detection), supporting a variety of system configurations.By installing a display unit (sold separately), measured data can be displayed on the module.The display unit can be set vertically or horizontally, since its "rotation mechanism" allows the unit rotation of 90 degrees in both right and left directions
Performance specifications
211 212
OtherOther
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Protective Relay
Features
MELPRO-D series
Phase/wire typeRated voltageRated currentMeasured values
No. of occupied stations
Item EMU-C3P5
250 A/100 A/50 A (selectable)
EMU-C3P5-5A
5A (current on the primary side current sensor)
Single phase 2-wire / single phase 3-wire / 3 phase 3-wire (selected by the setting switch)110/220 V (selected by the setting switch)
Current (each phase, total, demand, and max. demand value)Voltage (each phase, total, and max. value)
Electric power (current, demand, and max. demand value)Electric energy (integration value, hourly integration value, and max. value of hourly electric energy)
Leakage current (current value, demand value, and max. demand value)Time of max. value detection
1 station (remote device station)
Advanced communication network compatible relay supports automatic power distribution.
Performance specifications
Full access is available from the central control system.(Integer constant, measured value, operating status, constant monitoring, time, etc.)
A wide range of models is applicable to protection of various high-voltage or extra-high-voltage systems. (Protection for power distributor, transformer, motor, power generator, system interconnection, etc.)
Various measurement functions are available.(Error memory, measurement of current, voltage, power, frequency, etc.)
Other features include:
Programmable contacts (Any values can be set as output contacts using or logic)
Highly accurate protection of high-speed sampling using digital calculation
Advanced constant monitoring function
Drawer mechanism designed for ease of maintenance
213 214
OtherOther
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
MemoMemoMemo
CC-Link (Version1.10) specifications T-Branch communication specifications(When repeater (T-Branch) modules are not used)
Maximum no. of link points
No. of link points per station
Remote I/O (RX, RY)Remote register (RWw)Remote register (RWr)
10M/5M/2.5M/625k/156kbpsBroadcast polling methodFrame synchronous methodNRZI methodBus type (conforming to EIA RS485)Conforming to HDLCCRC (X16 + X12 + X5 + 1)64 modules. However, the following conditions must be satisfied.
Item
Con
trol
spec
ifica
tion
Com
mun
icat
ion
spec
ifica
tion
Fun
ctio
n
Specification
Transmission rate156kbps625kbps2.5Mbps5Mbps10Mbps
Auto refresh function *1
RAS function(Standby master, automatic return, slave station separation, error detection by link special relay and register, test/monitor)
Remote I/O network mode *1
Scan synchronizationAutomatic CC-Link startup *2
Reserved station specificationError invalid station specificationSupport for redundant system *2
*1 May not be supported depending on CPUs to be used together.*2 This function is available only for the Q series.
(1 x a) + (2 x b) + (3 x c) + (4 X d) <= 64a: No. of modules occupying 1 station, b: No. of modules occupying 2 stations, c: No. of modules occupying 3 stations, d: No. of modules occupying 4 stations(16 X A) + (54 X B) + (88 X C) <= 2304A: No. of remote I/O stations Max. 64B: No. of remote device stations Max. 42C: No. of local, standby master, intelligent device stations Max. 26
Max. total cable length1200m900m400m160m100m
Cable length between stations
20cm or more
Master station
Cable lengthbetween stations
Max. total cable length
Remote I/O station or remote
device station
Remote I/O station or remote
device station
Local station or intelligent device station
Local station or intelligent device station
Remote I/O (RX, RY)Remote register (RWw)Remote register (RWr)
1 to 64
: 2048 points each: 256 words: 256 words: 32 points each: 4 words: 4 words
Communication speedTransmission methodSynchronous methodEncoding methodTransmission pathTransmission formatError control system
No. of connected modules
Remote station number
Max. total cable length and cable length between stations
Connection cable
If cables compatible with Version 1.10 and Version 1.00 are used together, the specifications of Version 1.00 are used for maximum total cable length and cable length between stations.
Dedicated cable compatible with CC-Link Version 1.10 Use the dedicated cable certified by CC-Link Partner Association. Please note that operation will not be guaranteed if the other cable is used. Cables of different manufacturers can be used together if they support Version 1.10. For the specifications of the CC-Link dedicated cable or vendor information, refer to the partner
product catalogs published by CC-Link Partner Association or visit its web site at http://www.cc-link org.
CC-Link Version 1.10 cable (Terminating resistor 110 is used)
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Remote I/O /remote device station
Local station/intelligent
device station
Local station/intelligent
device station
Local station/intelligent
device station
Master station
System configuration
R Master station
R
R
RL/I L/I
R R RR
R
L/I
R
R R R R
L/I L/I
Terminatingresistor
Terminatingresistor
Branch line
Up to connect up to 6 modules are connectable. Up to connect up to 6 modules are connectable.
T-branchTerminal block/connector
Trunk line
Branch line Branch line Branch line
625kbps100m
50m
625kbps156kbps
Communicationspeed
Max. trunkline length
Distance betweenT-branch lines
Cable length between remote I/Ostations or remote device stations *1
Cable length between the master, local or intelligent device station and adjacent station *2
*1 1m or more, in case of a system configuration with remote I/O and remote device stations only.*2 2m or more, in case of a system configuration that includes local station(s) and intelligent device station(s).
Indicates a remote I/O station or a remote device station.
Indicates a local station or an intelligent device station.
100m500m
No limit 30cm or more 1m or more (*1) / 2m or more (*2)
10M, 5M and 2.5Mbps cannot be used.Cable length between terminating resistors, not including any T-branch cable length
Total cable length per branchOverall branch cable length
Total no. of connectable modules is conformed to the CC-Link specifications.
ItemTransmission rate
Max. trunk line lengthMax. branch lengthTotal branch length
Max. no. of modules/branch
Specification Remarks
Connection cable
T-branchTerminal block
/connector
Max. trunk line length,distance betweenT-branch lines,
length, and cable length between stations
Item not listed below are conformed to the CC-Link specifications.The table below lists the communication specifications for T-branch connections without repeater (T-branch) modules.
156kbps500m
200m8m
6 per branch
*2Terminatingresistor
Terminatingresistor
Max. trunk line length (not including branch line length)
(Branch line length is 8m or less)
(Branch line length is 8m or less)
*2 *2
*2
*2
*2 *2 *2*1
*1
*1
*1
*1 *1 *1 *1
CC-Link dedicated cable
Terminal block: Any commercially available terminal block Connector: FA sensor connectors compliant with NECA4202 (IEC947-5-2) or equivalent are recommended. (NECA: Nippon Electric Control Equipment Industries Association standard)
CC-Link dedicated cable (Terminating resistor 110 is used)
Do not use CC-Link dedicated high performance cables (e.g., FANC-SBH). Do not use cables of different manufacturers together.
When wiring, do not strip the trunk line cable sheaths as much as possible.
215 216
Technical InformationTechnical
Information
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
CC-Link communication
Bit transmissionWord transmission
Dedicated instruction
Data of 32 input points and 32 output points per station can be transmitted.Data of 4 points can be read or written per station.Transient transmission is executable to local stations or intelligent device stations.
Network parameters
PLC CPU
Cyclic transmission
Transient transmission
Master station Remote I/O station(station No. 1)
Remote device station(station No. 2)
Local station(station No. 3)
Local station(station No. 4)
X
X
X
X
Y
Y
Y
Y
D
D
D
D
D
D
Network parameters
Buffer memory Buffer memory Buffer memory
Remote output (RY)
Remote register (RWw)
Remote register (RWr)
Buffer for transienttransmission
Buffer for transienttransmission
Remote input (RX)
Remote input (RX)
Remote input (RX)
Remote output (RY)
Remote output (RY)
Remote register (RWw)
Remote register (RWr)
Receive area from remote I/O
station no. 1Receive area
from remote devicestation no. 2
Receive area fromlocalstation no. 3
Receive area fromlocal station no. 4
Send area to remote I/O station
no. 1Send area to
remote device stationno. 2
Send area to localstation no. 3
Send area to localstation no. 4
Send area to localstation no. 3
Send area to localstation no. 4
Not used(station no. 1)
Dedicated instruction
Dedicated instruction
Receive area from remote device station
no. 2
Transienttransmission
Cyclictransmission
Buffer for transienttransmission
Buffer for transienttransmission
This station(station no. 4) send area
Receive area from local station no. 3
Receive area from local station no. 4
Not used(station no. 1)Send area from
remote device station no. 2
Remote input (RX)
Remote register (RWr)
Remote register (RWw)
Remote output (RY)Receive area
from remote I/O station no. 1
Receive area from remote device
station no. 2
Receive area(station no. 1) fromthe master station
Receive area(station no. 2) fromthe master station
Receive area(station no. 3) fromthe master station
Receive area(station no. 4) fromthe master station
Receive area(station no. 2) fromthe master station
Receive area(station no. 3) fromthe master station
Receive area(station no. 4) fromthe master station
Receive area from remote device station
no. 2
This station (station no. 3) send area
This station(station no. 3) send area
Receive area from local station no. 4
Receive area fromlocal station no. 4
Not used(station no. 1)
Not used(station no. 1)
Remote input (RX)
Remote register (RWr)
Remote register (RWw)
Remote output (RY)
Receive area fromremote device station
no. 2
Receive areafrom remote I/O
station no. 1
Receive area from localstation no. 3
This station(station no. 4) send area
Receive area(station no. 1) fromthe master station
Receive area(station no. 2) fromthe master station
Receive area(station no. 3) fromthe master station
Receive area(station no. 4) fromthe master station
Receive area (station no. 2) from the master station
Receive areafrom remote device
station no. 2Receive area
from localstation no. 3
Receive area (station no. 3) from the master station
Receive area (station no. 4) from the master station
Not used(station no. 1)
Not used(station no. 1)
Refresh parameters
CC-Link specifications
CC-Link Version 1.00 specifications (Differences from Version 1.10)
Max. total cable length and cable length
between stations
Connection cable
156kbps625kbps2.5Mbps
5Mbps
10Mbps
Max. totalcable length
1200m600m200m110m150m50m80m100m
Cable length between stations
1m or more A)/
2m or more B)
*1
30 cm or more
30cm to 59cm60 cm min.
30cm to 59cm60cm to 99cm
1m or more
*2
CC-Link dedicated cable (Terminating resistor 110Ω is used)
Master station
Transmissionrate
Maximum total cable length
*2
*1 Cable length between remote I/O stations or remote device stations*2 Cable length between the master, local or intelligent device station and adjacent station
When a cable length within the above range is used between remote I/O stations or remote device stations, the corresponding max. total cable length should be applied.
*1 *2 *2
Remote I/O station or remote
device station
Remote I/O station or remote
device station
Local station or intelligent
device station
Local station or intelligent
device station
1m or more, in case of a system
configuration with remote I/O and
remote device stations only.
2m or more, in case of a system
configuration that includes local
station(s) and intelligent device
station(s).
A) :
B) :
Item Specification
The following 2 items of the CC-Link Ver.1.00 are different from those of Ver.1.10:Maximum total cable length and cable length between stationsConnection cable
CC-Link dedicated cable/CC-Link dedicated high performance cable The dedicated cable and dedicated high performance cable cannot be used together. Cables of different manufacturers cannot be used together.
TechnicalInformation
TechnicalInformation
217 218
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Differences Between CC-Link Versions 2 and 1 CC-Link/LT specifications
CC-Link/LT network wiring specifications
With Ver. 2, the cyclic data size can be increased through extended cyclic setting.
CC-Link Ver. 1 specifications
Max. number of link pointsNo. of link points per station
No. of link points for each no. ofoccupied stations
No. of connected modules
1 station occupied2 stations occupied3 stations occupied4 stations occupied
Item Specification
Remote I/0 (RX, RY): 2048 points each Remote register (RWw): 256 words Remote register (RWr): 256 wordsRemote I/0(RX, RY): 32 points each Remote register (RWw): 4 words each Remote register (RWr): 4 words eachRemote I/0 (RX, RY): 32 points each Remote register (RWw): 4 words each Remote register (RWr): 4 words eachRemote I/0 (RX, RY): 64 points each Remote register (RWw): 8 words each Remote register (RWr): 8 words eachRemote I/0 (RX, RY)]: 96 points each Remote register (RWw): 12 words each Remote register (RWr): 12 words eachRemote I/0 (RX, RY): 128 points each Remote register (RWw): 16 words each Remote register (RWr): 16 words each
1) Total no. of stations(1 x a) + (2 x b) + (3 x c) + (4 x d) <= 64a: No. of modules occupying 1 station, b: No. of modules occupying 2 stations, c: No. of modules occupying 3 stations, d: No. of modules occupying 4 station
2) No. of connected modules(16 x A) + (54 x B) + (88 x C) <= 2304A: No. of remote I/O stationsB: No. of remote device stationsC: No. of local, standby master and intelligent device stations
Max. 64Max. 42Max. 26
CC-Link Ver. 2 specifications
Max. number of link pointsExpanded cyclic setting
No. of link points per station
Remote I/0 (RX, RY)Remote register (RWw)Remote register (RWr)Remote I/0 (RX, RY)Remote register (RWw)Remote register (RWr)Remote I/0 (RX, RY)Remote register (RWw)Remote register (RWr)
Remote I/0 (RX, RY)Remote register (RWw)Remote register (RWr)Remote I/0 (RX, RY)Remote register (RWw)Remote register (RWr)
1 station occupied
2 stations occupied
3 stations occupied
4 stations occupied
No.
of l
ink
poin
ts fo
r ea
choc
cupi
ed s
tatio
ns
No. of connected modules
Single Double Quadruple Octuple
Item SpecificationRemote I/0 (RX, RY): 8192 points each, Remote register (RWw): 2048points, Remote register (RWr): 2048points
1) Total no. of stations(a + a2 + a4 + a8) + (b + b2 + b4 + b8) x 2 + (c + c2 + c4+c8) x 3 + (d + d2 + d4 + d8) x 4 <= 64
2) No. of all remote I/O points(a x 32 + a2 x 32 + a4 x 64 + a8 x 128) + (b x 64 + b2 x 96 + b4 x 192 + b8 x 384) + (c x 96 +c2 x 160 +c4 x 320 + c8 x 640) + (d x 128 + d2 x 224 + d4 x 448 + d8 x 896) <= 8192
3) No. of all remote register words(a x 4 + a2 x 8 + a4 x 16 + a8 x 32) + (b x 8 + b2 x 16 + b4 x 32 + b8 x 64) + (c x 12 + c2 x 24 + c4 x 48 + c8 x 96) + (d x 16 + d2 x 32 + d4 x 64 + d8 x 128) <= 2048
4) No. of connected modules16 x A + 54 x B + 88 x C <= 2304A: No. of remote I/O stations Max. 64B: No. of remote device stations Max. 42C: No. of local and intelligent device stations Max. 26
32 points each4 words4 words
32 points each4 words4 words
64 points each8 words8 words
96 points each12 words12 words
128 points each16 words16 words
32 points each8 words8 words
32 points each8 words8 words
96 points each16 words16 words
160 points each24 words24 words
224 points each32 words32 words
64 points each16 words16 words
64 points each16 words16 words
192 points each32 words32 words
320 points each48 words48 words
448 points each64 words64 words
128 points each32 words32 words
128 points each32 words32 words
384 points each64 words64 words
640 points each96 words96 words
896 points each128 words128 words
* 2) and 3) are Ver. 2 mode only; calculation is necessary.* There is no change in the cable and wiring specifications for CC-Link Ver. 2. Use Ver. 1 cable for the connection of Ver. 2 devices.
Max. no. of link points (When I/O is used) No. of link points per station (When I/O is used)
Link scantime (ms)
Transmission rate (bps)ProtocolNetwork topologyError control methodNo. of connected modulesRemote station numbersMax. no. of connectable modules per in branchDistance between stationsDistance between T-branch linesMaster station connection positionRAS functionsConnection cable
No. of points2.5Mbps625kbps156kbpsNo. of points2.5Mbps625kbps156kbps
2.5 M/625 k/156 kBITR (Broadcast polling + Interval Timed Response)T-branchCRC641 to 648No restrictionNo restrictionConnected to the end of the trunk lineNetwork diagnostics, internal loopback diagnostics, slave station separation, automatic return to systemDedicated flat cable (0.75mm2 x 4), VCTF cable, Flexible cable
4-point mode256 points (512 points)
4 points (8 points)128 points
0.72.28.0
256 points1.24.315.6
8-point mode512 points (1024 points)
8 points (16 points)256 points
0.82.710.0
512 points1.55.420.0
16-point mode1024 points (2048 points)
16 points (32 points)512 points
1.03.8
14.11024 points
2.07.4
27.8
Item
---
Cable length between terminating resistors (Branch line length not included)
-Cable length per branch
Sum of all branch line lengths*1 Always install the master module at one end of the trunk line.*2 Install a terminating resistor near the master module (within 20 cm).
*3 The length of a line branched from a branch line is also included in the max. branch line length and overall branch line length.*4 Cables cannot be connected between branch lines.
T-branch connectionT-branch interval
Trunk line
Branch line
*4
Branch length
Branchlength
Terminatingresistor
RemoteI/O station
RemoteI/O station
RemoteI/O station Remote
I/O station
RemoteI/O station
RemoteI/O station
RemoteI/O station
RemoteI/O station
Remotedevice station
RemoteI/O station
Power supplyadaptor
Trunk line length (branch line length not included)
Master station
Transmission rateDistance between stationsMax. no. of connectable modules per branch
Max. trunk line length
Distance between T-branch linesMax. branch line lengthOverall branch line length
2.5Mbps
35m
4m15m
156kbps
500m
60m200m
625kbpsNo restriction
8 units
100m
No restriction16m50m
Item Specifications Remarks
*1
*2
*3
1 Different types of cables cannot be used together on the trunk line.
2 Different types of cables cannot be used together on the same branch line.
3 Dedicated flat cables, VCTF cables and flexible cables can be used together for branch lines. * The wiring specifications will not change due to the cable type used or combined use of different cable types.
* When the module with cable (e.g. CL1Y2-T1D2S) is used, shortening the dedicated flat cable length to 20cm or less allows connection to a different type of cable.
a: No. of modules occupying 1 station in single settingb: No. of modules occupying 2 stations in single settingc: No. of modules occupying 3 stations in single settingd: No. of modules occupying 4 stations in single settinga2: No. of modules occupying 1 station in double settingb2: No. of modules occupying 2 stations in double settingc2: No. of modules occupying 3 stations in double settingd2: No. of modules occupying 4stations in double setting
a4: No. of modules occupying 1 station in quadruple setting b4: No. of modules occupying 2 stations in quadruple settingc4: No. of modules occupying 3 stations in quadruple settingd4: No. of modules occupying 4 stations in quadruple settinga8: No. of modules occupying 1 station in octuple setting b8: No. of modules occupying 2 stations in octuple settingc8: No. of modules occupying 3 stations in octuple settingd8: No. of modules occupying 4 stations in octuple setting
Con
trol
spe
cific
atio
nsC
omm
unic
atio
n sp
ecifi
catio
ns
When 32 stations are connected
When 64 stations are connected
Precautions for using different types of cables together
Terminatingresistor
219 220
TechnicalInformation
TechnicalInformation
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
CC-Link/LT cable specifications Terminology list
General specifications
CC-Link/LT dedicated flat cable specifications
Cross section
0.75mm2 30/0.18mm 1.1mm 0.6mm 1.0mm
VCTF cable specifications (quoted from JIS C 3306 standard)
Manufacturer nameMITSUBISHI ELECTRIC SYSTEM & SERVICE; CO., LTD.
DAIDEN CO., LTD.Yoshinogawa Electric Wire & Cable Inc.
KURAMO ELECTRIC CO., LTD.
List of flexible cables certified by CC-Link partner AssociationThe following CC-Link Association certified dedicated flexible cables should be used.
Dedicated Flexible cable modelCL9-MV4-075
CM/LT(2586) AWG19/4CCRFV-A075C04-LT
FANC-Z/LT
Base color (light blue) Polarity mark (orange)
10.16mm
2.54mm
2.5
4m
m
CC-Link
-20 to 75˚C*4
10 to 90% RH, no condensation allowed *5
(The waterproof type remote I/O modules conform to the IP67 standard. *7)10 to 90% RH, no condensation allowed *6
CC-Link/LT
-25 to 75˚C*5
5 to 95% RH, no condensation allowed(conforming to JIS B 3502, IEC61131-2, level RH-2)
5 to 95% RH, no condensation allowed
0 to 55˚C*4
Frequency10 to 57Hz
57 to 150Hz10 to 57Hz
57 to 150Hz
Under intermittentvibration
Under continuousvibration
Acceleration-
9.8m/s2
-4.9m/s2
Amplitude0.075mm
-0.035mm
-
Sweep count
10 times each in X, Y, Z
directions (for 80 minutes)
Conforming to JIS B 3502, IEC61131-2
Operating ambient temperatureStorage ambient temperatureOperating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistanceDielectric withstand voltage *1
Insulation resistor *1
Operating atmosphereOperating altitudeInstallation placeOvervoltage category *2
Pollution level *3
Item
Operating ambient temperature
Not wired (product only)
Wired (after inserting cable)
Storage ambient
temperature
ACPUA generic term for the A1CPU, A2CPU (-S1), A3CPU, A1NCPU, A2NCPU (-S1), A3NCPU, A3MCPU and A3HCPU.
Additional modeA mode used when a Ver.2 slave station is added to the system configured in the Ver.1 mode. Use of this mode can reduce steps for program modification.
AnACPUA generic term for the A2ACPU (-S1) and A3ACPU.
AnSCPU A generic term for the A1SCPU, A1SJCPU (-S3) and A2SCPU.
AnSHCPUA generic term for the A1SHCPU, A1SJHCPU and A2SHCPU.
AnUCPUA generic term for the A2UCPU (-S1), A3UCPU and A4UCPU.
AnUSCPUA generic term for the A2USCPU (-S1) and A2USHCPU-S1.
Automatic returnThis function allows a module disconnected from the data link (due to power-off, etc.) to automatically rejoin the data link when the module is recovered to normal status.
A0J2(H)CPUA generic term for the A0J2CPU and A0J2HCPU.
Bit data1-bit data that is represented as either 0 (OFF) or 1 (ON)
Broadcast polling method A method by which polling and data communication to each station is performed using the same communication packet, which in turn transmits data to all stations simultaneously.
Cyclic transmissionA communication method where data are refreshed across the CC-Link network periodically
Error invalid station settingA setting that prevents a station specified with a network parameter from being treated as a data link error station. This setting allows the station to stay ON even in the case where it is to be turned OFF in the system configuration.
Extended cyclic setting In the extended cyclic transmission, the extended cyclic points can be set as 2 times, 4 times or 8 times of the normal cyclic transmission points.
I/O modeA mode in which the PLC CPU cannot receive transient transmission requests from intelligent device stations.
Intelligent device moduleA module that can perform transient transmission (AJ65BT-R2, local station module, etc.).
Intelligent device stationA station that can perform cyclic transmission and transient transmission on a 1:n basis with the master station (AJ65BT-R2, local station, etc.).
Intelligent modeA mode in which the PLC CPU can receive transient transmission requests from intelligent device stations.
Local moduleA generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11 and A1SJ61QBT11 modules when used as local stations.
Local stationA station that can perform n: n cyclic transmission and transient transmission with the master station and other local stations. It can also monitor RX, RY, RWr and RWw of remote stations.
Master/local moduleA generic term for the QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11 and A1SJ61QBT11 modules.
Master module A generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11 and A1SJ61QBT11 modules when used as master stations.
Master stationA station that controls one or more slave stations (remote I/O stations, remote device stations, intelligent device stations and/or local stations). The master station retains control information (parameters) and controls the entire network. One master station is required per network system.
Message Data that is exchanged by transient transmission.
Number of modulesThe number of physical devices connected to one CC-Link network.
Number of stationsThe total number of occupied stations of all slave stations connected to the CC-Link network.
No. of stations occupiedThe number of stations used by a single slave station. One to four stations can be set depending on the number of data. A remote I/O station can only be set to occupy one station.
QCPU (A mode) A generic term for the Q02CPU-A, Q02HCPU-A and Q06HCPU-A.
QCPUA generic term for the Q00JCPU, Q00CPU, Q01CPU, Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU, Q12PH and Q25PH.
Off-line testThe hardware test (operation check of the module), line test (connection status check) and parameter check test (check of set parameters) can be performed.
QnACPUA generic term for the Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU, Q2ASHCPU-S1, Q2ACPU, Q2ACPU-S1, Q3ACPU, Q4ACPU and Q4ARCPU.
RAS functionR (Reliability) A (Availability) S (Serviceability).
Remote device stationA remote station that can handle bit data and word data (Input from/output to external devices, analog data exchange: AJ65BT-64AD, AJ65BT-64DAV and AJ65BT-64DAI, etc.)
Remote I/O network modeA special mode used for high-speed data communication with remote I/O stations (Using this mode can reduce the link scan time when the system consists of a master station and remote I/O stations only.)
Remote I/O station A remote station than can only handle bit data and occupy only one station. (Input from/output to external devices: AJ65BTB1-16D, AJ65SBTB1-16D, etc.)
Remote network modeA mode in which the master station can communicate with all stations on the CC-Link network (remote I/O stations, remote device stations, local station, intelligent device stations and the standby master station).
Remote stationA generic term for remote I/O stations and remote device stations; controlled by the master station.
Reserved stationWhen a station is to be connected to the network in the future, setting the station as a reserved station prevents it from being treated as a data link error station. If a connected module is specified for this, it cannot perform the data link.
RWrRemote register (read area): Word data transmitted to each station using cyclic transmission. For convenience, the area that stores this information is expressed as RWr. Input data is referred to as RWr at the master station.
RWw Remote registers (write area): Word data transmitted to each station using cyclic transmission. For convenience, the area that stores this information is expressed as RWw. Output data is referred to as RWw at the master station.
RXRemote input: Bit data transmitted to each station using cyclic transmission. For convenience, the area that stores this information is expressed as RX. Input data is referred to as RX at the master station.
RYRemote output: Bit data transmitted to each station using cyclic transmission. For convenience, the area that stores this information is expressed as RY. Output data is referred to as RY at the master station.
SBLink special relay: Special bit data that stores the data link status (either ON or OFF) of the master station, local station and intelligent device station. This area is expressed as SB for convenience.
Slave stationA generic term for stations other than the master station (remote I/O station, remote device station, intelligent device station, and local station).
Slave station separationWhen a module on a network has failed to perform the data link due to some reason such as power-off, it is disconnected from the network and only normal modules continue the data link.
Station A device that exists on the CC-Link network, where the station number assignment can be from 0 to 64.
Station number This is used to distinguish between stations on the CC-Link network. Zero is assigned to the master station, and any of 1 to 64 can be assigned to a slave station. Unique station numbers without duplication must be used.
Standby master stationIf the master station is forced to stop due to an error, this station inherits the master station control. The standby master station has functions equivalent to those of the master station, and operates as a local station when there are no errors in the master station.
SWLink special register: Special word data that stores the data link status of the master station, local station and intelligent device station. This area is expressed as SW for convenience.
Transient transmissionThis type of communication is performed between 1:1 stations when required in a specific time instance.
Ver. 1 modeMode of conventional CC-Link (Ver. 1.10)
Ver. 2 modeIn this mode, cyclic data can be increased with extended cyclic setting.
Word dataData type consisting of 16 bits. One word data can express a value between “-32,768 and 32,767” in signed decimal, between “0 and 95,535” in unsigned decimal, and between “0 and FFFFh” in hexadecimal.
Item
Item
TypeNumberof cores
4
Conductor
Nominal cross-section area
No. of strands/stand diameter
Outsidediameter
Insulatorthickness
Sheaththickness
Specification
Specification
Vinyl cabtyre round cord
*5: The ambient operating/storage temperatures satisfy requirements in excess of the JIS B 3502, IEC61131-2 standards.
*6: Use the master module for the Q Series within an ambient operating humidity of 5 to 95%.
*7: This is applicable to conditions where waterproof connectors are used for all modules or waterproof caps are placed in unused through-pipes.
*8: Do not operate or store the programmable logic controller at altitude 0m or more in a pressurized environment. It may malfunction if it is operated.Contact us when operating in a pressurized state.
*1: Interface boards for use in PCs depend on the PC used.*2: This indicates to which power-distribution area the device is connected until it reaches
the mechanical device within the premises from the public distribution grid.Category II is applied to devices to which power is supplied from a fixed facility.Voltage-surge resistance of devices is provided up to a rating of 300 V is 2500 V.
*3: This index shows the degree of generation of conductive substances in the environment where the device is used.Only non-conductive pollution occurs in pollution level 2. However, conduction may occur temporarily due to accidental condensation.
*4: The table below shows the operating ambient temperature and storage ambient temperature for the AJ65SBTW4-16 type waterproof remote I/O modules and Q Series master module.
Flat cable-10 to 80 C30V423.4 /Km or lessUL Subject758UL VW-1 -F-
Cable typeOperating temperature rangeRated voltageNumber of core wiresConductor resistance (20 C)SafetyFlame resistance
25.1 /km
Conductorresistance (20 C)
Conforming to JIS B 3502, IEC 61131-2 (147m/s2, 3 times in each of directions X, Y, Z)500 VAC across all DC external terminals and ground for 1 min
500 VAC across all DC external terminals and ground, 10 M or more by insulation resistance testerNo corrosive gases
Conforming to JIS B 3502, IEC 61131-2 (2000 m or less) *8
Inside control panelConforming to JIS B 3502, IEC 61131-2 (category II or less)
Conforming to JIS B 3502, IEC 61131-2, pollution level 2 or less
AJ65FBTA-RPH
0 to 45 C
-25 to 75 C
-
Q Series
Master module
0 to 55 C
-25 to 75 C
-
AJ65SBTW4-16 0 to 45 C
-20 to 65 C
-10 to 55 C
221 222
TechnicalInformation
TechnicalInformation
Other/
Softw
areE
mbedded
Technical
Information
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
ed
Icon Identification
Connection Types
Input
Output
Others
This is the most popular type of cable connection, and screws are used for device connection.
Modules equipped with self-up screws enable cable connection without removing terminal screws. (Modules adopting the “Finger protect” design) * Finger protect
This allows installation of a module without contact with its live part.
Screw T. block
Cable connection can be made by inserting a cable and clamping it with a spring. Because no screw tightening is required, cables can be connected or disconnected easily with excellent contact reliability and high resistance to vibration.Note that a dedicated tool must be used not to damage the terminal block and its coating.
The industry standard “e-CON” system allows easy sensor replacement for each plug.This connection type supports a wide range of cable diameters and realizes excellent contact reliability by using a press-fitting method.Wiring steps can be drastically reduced since soldering, stripping and screwing are not needed.Dedicated pliers are available although commercially available pliers can also be used.
By inserting individual cables into the plug and pressing the plug into the connector, cables can be connected.Wiring steps can be drastically reduced since soldering, stripping and screwing are not needed.
Use of 40-pin connector allows connections to various devices.Cable connection made easily by inserting or removing connectors remarkably reduces wiring steps.
Adoption of the IP67-compliant waterproof structure allows installation in the environment where it may be exposed to water or moisture and also outside panels.
This type can be connected to devices meeting the MIL standard.Connection to a relay terminal or terminal block converter module is easy, and modules can be replaced simply by using the connector.
This type can be set in a conduit like general cables.A communication cable and an external device connection cable is integrated, which enables easy wiring.Two-point input, 2-point output and 1-point input/output modules are available, allowing connection to devices of small I/O points.
Sensor
Spring clamp
Embedded
Waterproof
40-pin
Push-in
VerticalProtection
Cable
This type can be mounted to boards that have been designed and manufactured by customers, and can be embedded to devices.
MIL
DC input and AC input power supply types are available.
Number of input points available for the module is indicated.4-point, 8-point, 16-point, and 32-point modules are available.
Number of input points available for communication of the module is indicated.Modules that can handle data amount of 2-point, 4-point, 8-point and 16 points are available.
The positive common input is DC input in which input terminals are positive. Connecting an input terminal to the negative pole turns ON the circuit. Connections to switches, relays, NPN transistor output of sensors, etc. are available. Widely used in Japan and the U.S.A.
Upper part: Power supply specifications
Lower part: Number of input points
The rated input voltage is indicated.Please observe the specifications to prevent failure or damage of input terminals.
Modules supporting 1- to 4-wire types are available.Select a connection type suitable for the specifications of the connected device.
Upper part: Input voltage
Lower part: Connection format
The negative common input is DC input in which input terminals are negative. Connecting an input terminal to the positive pole turns ON the circuit. Connections to switches, relays, PNP transistor output of sensors, etc. are available. Widely used in Europe.
This indicates the output type of the output module outputting ON/OFF signals.There are the following 3 types: Non-contact transistor output for DC, non-contact triac output for AC and relay output for AC/DC.
Number of output points available for the module is indicated.4-point, 8-point, 16-point, and 32-point modules are available.
Number of output points available for communication of the module is indicated.Modules that can handle data amount of 2-point, 4-point, 8-point and 16 points are available.
A transistor is used for this DC output type, and current flows from a load to an output terminal when the output turns ON.Connect a load between an output terminal and the positive terminal of the power supply.Widely used in Japan and the U.S.A.
This type has a function by which the response speed of an input filter (input time constant) can be switched between “High –speed” and “Standard”. The “High-speed” setting increases the accuracy while more noise may be picked up.
Excessive current or voltage may damage a module by heat. This protective function stops the module to prevent its damage in such a case.
In the event of a communication error, this function allows the module to hold the output data immediately before the error without clearing. Whether to hold or clear the data can be changed in the setting.
The overload (overcurrent) protection, overvoltage protection and overheat protection functions have been provided.
The overload (overcurrent) protection and overheat protection functions have been provided.
Upper part: Type specifications
Lower part: Number of output points
The maximum load current is indicated.Current exceeding this will damage the elements of output modules. The maximum current can be discharged through a common line.
Modules supporting 1- to 4-wire types are available.Select a connection type suitable for the specifications of the connected device.
Upper part: Output load current
Lower part: Wire type
A transistor is used for this DC output type, and current flows from an output terminal to a load when the output turns ON.Connect a load between an output terminal and the negative terminal of the power supply.Widely used in Europe.
Input switch Hold
The module can be vertically installed. This enables module installation in small spaces.
The module has a high-speed input response time.
The module has minimal current leakage when the output signal is OFF.
The cyclic data amount can be increased up to 8 times in the setting compared with the old models. This setting can reduce unused points.
Overload (overcurrent) protection function:This function prevents a current exceeding a prescribed level from flowing to output elements. Although output devices turn on or off properly even if an excessive current flows, if the condition is kept unchanged, the overheat protection function will be activated.When the protection function is triggered, recover the external output devices as soon as possible.Overheat protection function:This function stops the operation when an output element is extraordinarily heated. This function is activated when an excessive current flows to an output element due to short circuit, or when surge occurs frequently.
High-speed
Low leakage
-wire224VDC
DC input
pt1
Transistoroutput
pt1
-wire20.1A
223 224
TechnicalInformation
TechnicalInformation
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
CC-Link - Open and global network!CLPA is supporting the spread of CC-Link.
Exhibiting in trade shows, conducting conformance tests, sending out the latest information...Through these and other popularization activities, CLPA is extending the possibilities of CC-Link.
CC-Link - Open and Global!CC-Link is accelerating toward a global network.
6F Meiji Yasuda Seimei Ozone Bldg., 3-15-58, Ozone, Kita-ku, Nagoya 462-0825, JapanTEL : +81-52-919-1588 / FAX :+81-52-916-8655URL: http://www.cc-link.org E-mail: [email protected]
This web site provides the latest CC-Link information.The CC-Link Partner Association (CLPA) is an organization established to make the CC-Link, an open field network, spread worldwide. Through vigorous activities such as holding trade shows and/or seminars, conducting conformance tests, and offering information by catalogs, pamphlets and the Internet, the numbers of partner manufacturers and CC-Link compatible products have been increasing steadily.
Conformance tests support the rapid increase of compatible products. Exhibitions and seminars are held to recruit new partner members.
CC-Linkpromotion center ASEAN
CLPA-Headquarter
CLPA-Korea
CLPA-Taiwan
CLPA-North America
CLPA-EU
CC-Linkpromotion center China
CLPA has established CLPA offices all over the world in order to spread CC-Link to Japanese and overseas manufacturers. Through positive activities such as exhibiting in trade shows in the major cities and setting up conformance test organizations, CLPA sends out information designed to expand the potential of CC-Link and increasing the number of CLPA partners.
CC-Link Partner Association
CC-Link - Open and GlobalCC-Link - Open and GlobalCC-Link - Open and Global
225 226
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Support
http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/
MELFANSweb home page URL
Get more information on the Website. MELFANSweb answers your questions about Mitsubishi FA products.
Point 1 :Point 2 :
Point 3 :
MELFANSweb offers a variety ofFA device information.
"MELFANSweb" covers many kinds of information related to Mitsubishi FA devices. With over 100,000 hits each day, this website has received overwhelming support of the users. It contains various information such as technical news and product information to powerfully back up all of Mitsubishi FA product users. The advantages include:
Real-time internet search for the latest FA informationMore than 2000 online manuals with enormous amount of informationWide range of information from basic technique to advanced working-level CAD data
Support
CLPA-Headquarter6F Meiji Yasuda Seimei Ozone Bldg., 3-15-58, Ozone, Kita-ku, Nagoya 462-0825, JapanPhone:+81-52-919-1588 Fax:+81-52-916-8655
North America500 Corporate Woods Parkway, Vernon Hills, IL60061, U.S.A. Phone:+1-847-478-2341 Fax:+1-847-478-2253
CLPA-EUTravellers Lane, Hatfield, Hertfordshire, AL10 8XB U.K. (P.O.Box 50, Hatfiled, AL10 8XB U.K.) Phone:+44-1707-278953 Fax:+44-1707-282873
KoreaDongseo Game Channel Bldg. 2F, 660-11, Deungchon-Dong, Kangseo-ku, Seoul, 157-030, Korea Phone:+82-2-3663-6178 Fax:+82-2-3660-9509
China4F Block 5 Building Automation Instrumentation Plaza 103 Cao Bao Rd., Shanghai 200233, China Phone:+86-21-64940523 Fax:+86-21-64940525
Taiwan6th Fl, No.105, Wu Kung 3 Rd., Wu-Ku Hsiang, Taipei, Taiwan Phone:+886-2-8990-1573 Fax:+886-2-8990-1572
ASEAN307 Alexandra Road #05-01/02, Mitsubishi Electric Bldg., Singapore 159943 Phone:+65-64732308 Fax:+65-64767439
If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company.However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer's discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module.
Gratis Warranty Term
The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place.Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs.
Gratis Warranty Range
(1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc., which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product.
(2) Even within the gratis warranty term, repairs shall be charged for in the following cases.
1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design.
2. Failure caused by unapproved modifications, etc., to the product by the user.
3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided.
4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced.
5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage.
6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi.
7. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user.
(1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is discontinued.Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc.
(2) Product supply (including repair parts) is not available after production is discontinued.
Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ.
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation of damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not , compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.
The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice.
(1) In using the Mitsubishi MELSEC programmable logic controller, the usage conditions shall be that the application will not lead to a major accident even if any problem or fault should occur in the programmable logic controller device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault.
(2) The Mitsubishi programmable logic controller has been designed and manufactured for applications in general industries, etc. Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or Public service purposes shall be excluded from the programmable logic controller applications.In addition, applications in which human life or property that could be greatly affected, such as in aircraft, medical applications, incineration and fuel devices, manned transportation, equipment for recreation and amusement, and safety devices, shall also be excluded from the programmable logic controller range of applications.However, in certain cases, some applications may be possible, providing the user consults their local Mitsubishi representative outlining the special requirements of the project, and providing that all parties concerned agree to the special circumstances, solely at the users discretion.
227 228
Support
Oth
er/
Sof
twar
eT
echn
ical
Info
rmat
ion
Sup
port
Em
bedd
edO
ther/S
oftware
Em
beddedT
echnicalInform
ationS
upport
Responding to the amenable running of FA systems through an enhanced support system.
Shanghai FA CenterRYODEN AUTOMATION (SHANGHAI) LTD.1-3F Block5 Cao Bao Road. Shanghai 200233 ChinaTelephone +86-21-6484-9360/Fax +86-21-6121-2424Area covered: China
Beijing FA CenterRYODEN AUTOMATION (SHANGHAI) LTD. BEIJING OFFICEUnit 917-918, 9/F Office Tower 1, Henduson Center, 18 Jianguomennei Dajie, Dongcheng District, Beijing. 100005 ChinaTelephone +86-10-6518-8830/Fax +86-10-6518-8030Area covered: China
Taipei FA CenterSETSUYO ENTERPRISE CO., LTD.6F No.105 Wu Kung 3rd RD, Wu-ku Hsiang, Hsiene Taipei, TaiwanTelephone +886-2-2299-2499/Fax +866-2-2299-2509Area covered: Taiwan
Taichung FA CenterSETSUYO ENTERPRISE CO., LTD.7F-7, No.77, Zheng Bei 1st RD, Taichung City, TaiwanTelephone +886-4-2258-1027/Fax +866-4-2252-0967Area covered: Taiwan
ASEAN FA CenterMITSUBISHI ELECTRIC ASIA PTE, LTD.307 Alexandra Road #05-01/02 Mitsubishi Electric Building Singapore, 159943Telephone +65-6473-2480/Fax +65-6476-7439Area covered: Southeast Asia, India
North American FA CenterMITSUBISHI ELECTRIC AUTOMATION, INC.500 Corporate Woods Parkway, Vernon Hills, IL60061 U.S.ATelephone +1-847-478-2000/Fax +1-847-478-2396Area covered: North America, Mexico
European FA CenterMITSUBISHI ELECTRIC EUROPE B.V.GERMAN BRANCH(Industrial Automation Division)Gothaer Strasse 8 D-40880 Ratingen, GermanyTelephone +49-2102-486-2630/Fax +49-2102-486-7170Area covered: Europe
UK FA CenterMITSUBISHI ELECTRIC EUROPE B.V.UK BRANCH(Customer Technology Center)Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, UKTelephone +44-1707-276100/Fax 44-1707-278992Area covered: UK, Ireland
Korea FA CenterMITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.Dong seo Game Channel Bidg. 2F 660-11,Deungchon-dong, Kangseo-ku, Seoul, 157-030, KoreaTelephone +82-2-3660-9607/Fax +82-2-3663-0475Area covered: Korea
Hong Kong FA CenterMITSUBISHI ELECTRIC AUTOMATION (HONG KONG) LTD.10/F., Menulife Tower, 169 Electric Road,North Point, Hong KongTelephone +852-2887-8870/Fax +852-2887-7984Area covered: China
Tianjin FA CenterRYODEN AUTOMATION (SHANGHAI) LTD.TIANJIN OFFICERoom No.909, Great Ocean Building,No.200 Shi ZiLin Avenue, HeBei District, Tianjin 300143 ChinaTelephone +86-22-26359090/Fax +86-22-26359050Area covered: China
G l o b a l FA C e n t e r s
"Mitsubishi Global FA Centers" have been established at each of the North America, Europe and Asia regions for the development ofproducts matched to overseas planning and to enhance regional-based services. Full-time staff will provide you with optimum service.
Support
WARRANTY
Gratis warranty term and gratis warranty range
Onerous repair term after discontinuation of production
Overseas service
Exclusion of loss in opportunity and secondary loss from warranty liability
Changes in product specifications
Product application
Please confirm the following product warranty details before using this product.
MemoMemoMemo MemoMemoMemo
229 230
Module type
Remote I/O module
Analogmodule
High-speed counter module
Positioning modulePeripheral device connection moduleRS-232 interface moduleInterface boardfor personal computer
FX Series interface block
Repeatermodule
Sensor connector type
Immediate installationconnector type
40-pin connector type(FCN connector type)
Waterproof connector type
Screwterminalblock type
Immediateinstallationconnector type
IPindicationIP2XIP2X
IP2X
IP2X
IP1XBIP1XBIP2XIP2X
IP2X
IP2X
IP1XBIP1XB
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2XIP2XIP2XIP2X
IP2X
IP1XB
IP67IP67
IP67
IP67IP67
IP67
IP67
IP67
IP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2X
IP1XBIP1XBIP1XBIP2XIP2XIP2XIP2XIP2XIP2X
IP67
IP2XIP2XIP2XIP2XIP2X
Specifications
Output 8 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire typeOutput16 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire typeInput 8 points: 24 VDC/5 mA (positive common type) 3-wire type Response time 1.5 msOutput 8 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire typeInput 16 points: 24 VDC/5 mA (positive common type) 3-wire type Response time 1.5 msOutput 16 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire typeInput 8 points: 24 VDC (positive common) 3-wire type Response time 0.2 ms Immediate installation connector typeInput16 points: 24 VDC (positive common) 3-wire type Response time 0.2 ms Immediate installation connector typeInput16 points: 24 VDC (positive common) 4-wire type Response time 1.5 ms Immediate installation connector typeInput16 points: 24 VDC (negative common) 4-wire type Response time 1.5 ms Immediate installation connector typeInput 32 points: 24 VDC (positive common/negative common shared type) 1-wire type Immediate installation connector type (plug: sold separately) Response time 1.5 msInput 32 points: 24 VDC (positive common/negative common shared type) 1-wire type High-speed response Immediate installation connector type (plug: sold separately) Response time 0.2 msOutput 8 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire type Immediate installation connector typeOutput 16 points: 12/24 VDC (0.1 A) Transistor output (sink type) 2-wire type Immediate installation connector typeOutput 32 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (plug for immediate installation connector: sold separately)Output 32 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (low-leakage current type)Input 8 points: 24 VDC (positive common) 4-wire type (for 8 sensors) Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 4-wire type Immediate installation connector type (plug: sold separately)Input 8 points: 24 VDC (positive common) 4-wire type Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 4-wire type Immediate installation connector type (plug: sold separately) (low-leakage current type)Input 16 points: 24 VDC (positive common) 1-wire type Response time 1.5 msOutput 16 points: 24 VDC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (plug: sold separately)Input 16 points: 24 VDC (positive common) 1-wire type High-speed response Response time 0.2 msOutput 16 points: 24 VDC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (plug: sold separately)Input 16 points: 24 VDC (positive common) 1-wire type Response time 1.5 msOutput 16 points: 24 VDC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (plug: sold separately) (low-leakage current type)Input 16 points: 24 VDC (positive common) 1-wire type High-speed response Response time 0.2msOutput 16 points: 24V DC (0.1 A) Transistor output (sink type) 1-wire type Immediate installation connector type (plug: sold separately) (low-leakage current type)Input 32 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 1.5 ms FCN connector type (40-pin connector)Input 32 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 10 ms FCN connector type (40-pin connector)Output 32 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type FCN connector type (40-pin connector)Output 32 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type FCN connector type (40-pin connector)Input 16 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 1.5 ms Output 16 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type FCN connector type (40-pin connector)Input 16 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 0.2 msOutput 16 points: 12/24 VDC (0.1 A) Transistor output (sink type) 1-wire type FCN connector typeInput 24 VDC (positive common) 4-wire type Thin, waterproof type Response time 1.5 msInput 24 VDC (negative common) 4-wire type Thin, waterproof type Response time 1.5 msInput 16 points: 24 VDC Response time 1.5 ms Waterproof type 4-wire type (for 8 sensors)(positive common/negative common shared: select by switch) (cap: sold separately) Waterproof typeOutput 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire type Thin, waterproof typeOutput 16 points: 12/24 VDC (1.0 A) Transistor output (source type) 2-wire type Thin, waterproof typeInput 8 points: 24 VDC (positive common) 4-wire type Response time 1.5 msOutput 8 points: 24 VDC (0.5 A)Transistor output sink type 2-wire type Thin, waterproof typeInput 8 points: 24 VDC (negative common) 4-wire type Response time 1.5 msOutput 8 points: 24 VDC (1.0 A) Transistor output (source type) 2-wire type Thin, waterproof typeInput 8 points: 24 VDC (positive common) Waterproof type 4-wire type (for 8 sensors) Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) (cap: sold separately)4-channel voltage/current input A/D conversion module (analog input module)4-channel voltage/current input A/D conversion module (analog input module)4-channel Pt100 (3-wire type) input Platinum RTD Pt100 temperature input4-channel Pt100 (4-wire type) input Platinum RTD Pt100 temperature input8-channel thermocouple output Thermocouple temperature input module2-channel voltage/current input D/A conversion module (analog input module)4-channel voltage output D/A conversion module (analog input module)4-channel current output D/A conversion module (analog input module)CC-Link Ver.2-compatible 8-channel voltage input A/D conversion module (analog input module)CC-Link Ver.2-compatible 8-channel current input A/D conversion module (analog input module)CC-Link Ver.2-compatible 8-channel voltage output D/A conversion module (analog input module)DCinput Preset DC input Differential input Preset DC input Differential input Preset differential input 2axes (independent, w/ linear and circular interpolation)PC read/PC write/monitor/test of master and local stationsRS-232 1-channel, w/ DC input 2 points Transistor output 2 pointsCC-Link interface board for an IBM PC/AT compatible PC (for PCI bus slot: master station, standby master station or local station)
Interface block for FX1N, FX2N, FX3U, FX1NC, FX2NC, FX3UC Series
8-port star wiring hub module repeater function, IP67-compatible
8-port star wiring hub module repeater function, Spring clamp terminal block type
T-branch module w/ repeater functionFor SI/QSI type fiber cable (2 units used in combination)For GI type fiber cable (2 units used in combination)
AJ65BT-RPI-10A and AJ65BT-RPI-10B used as a pair, 156k/625k/2.5Mbps supported
Model name
AJ65VBTCE2-8TAJ65VBTCE2-16T
AJ65VBTCE32-16DT
AJ65VBTCE32-32DT
AJ65VBTCU3-8D1AJ65VBTCU3-16D1AJ65SBTC4-16DNAJ65SBTC4-16DE
AJ65SBTC1-32D
AJ65SBTC1-32D1
AJ65VBTCU2-8TAJ65VBTCU2-16T
AJ65SBTC1-32T
AJ65SBTC1-32T1
AJ65SBTC4-16DT
AJ65SBTC4-16DT2
AJ65SBTC1-32DT
AJ65SBTC1-32DT1
AJ65SBTC1-32DT2
AJ65SBTC1-32DT3
AJ65SBTCF1-32DAJ65BTC1-32DAJ65SBTCF1-32TAJ65BTC1-32T
AJ65SBTCF1-32DT
AJ65VBTCF1-32DT1
AJ65FBTA4-16DAJ65FBTA4-16DE
AJ65SBTW4-16D
AJ65FBTA2-16TAJ65FBTA2-16TE
AJ65FBTA42-16DT
AJ65FBTA42-16DTE
AJ65SBTW4-16DT
AJ65SBT-64ADAJ65BT-64ADAJ65BT-64RD3AJ65BT-64RD4AJ65BT-68TDAJ65SBT-62DAAJ65BT-64DAVAJ65BT-64DAIAJ65VBTCU-68ADVNAJ65VBTCU-68ADINAJ65VBTCU-68DAVNAJ65BT-D62AJ65BT-D62DAJ65BT-D62D-S1AJ65BT-D75P2-S3AJ65BT-G4-S3AJ65BT-R2
Q80BD-J61BT11N
FX2N-32CCL
AJ65FBTA-RPH
AJ65BTS-RPH
AJ65SBT-RPTAJ65SBT-RPSAJ65SBT-RPGAJ65BT-RPI-10AAJ65BT-RPI-10B
Module type
Master/local module
Remote I/O module
Screw terminal block type
Screw/2-pieceterminal block type
Spring clampterminal block type
Sensor connector type
IPindication
IP1XB
IP1XIP1XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP1XIP1XIP1XIP1X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2X
IP2XIP2XIP2XIP2XIP1X
IP2X
IP2X
IP1X
IP2XIP2XIP2XIP2X
IP2X
IP2X
IP2XIP2XIP2X
Specifications
Master/local module for AnN/AnA/AnUCPUMaster/local module for AnS/AnSH/AnUS/AnUSHCPUMaster/local module for QnACPUMaster/local module for QnAS/QnASHCPUMaster/local module for CC-Link Ver.2-compatible QCPUMaster block for FX Series (FX1N/FX2N/FX2NC/FX3UC)
Input 8 points: 100 to 120 VAC 2-wire type Response time 20 ms Terminal block typeInput 16 points: 100 to 120 VAC 2-wire type Response time 20 ms Terminal block typeInput 8 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 1.5 ms Terminal block typeInput 8 points: 24 VDC (positive common/negative common shared type) 3-wire type Response time 1.5 ms Terminal block typeInput 16 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 1.5 ms Terminal block typeInput 16 points: 24 VDC (positive common/negative common shared type) 1-wire type High-speed response Response time 0.2 ms Terminal block typeInput 16 points: 24 VDC (positive common/negative common shared type) 3-wire type Response time 1.5 ms Terminal block typeInput 32 points: 24 VDC (positive common/negative common shared type) 1-wire type Response time 1.5 ms Terminal block typeInput 32 points: 24 VDC (positive common/negative common shared type) 1-wire type High-speed response Response time 0.2 ms Terminal block typeOutput 8 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeOutput 8 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Output 8 points: 12/24VDC (0.5A) Transistor output (sink type) 2-wire type Terminal block typeOutput 8 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block type (low-leakage current type)Output 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeOutput 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Output 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block typeOutput 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block type (low-leakage current type)Output 32 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeOutput 32 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Output 8 points: 12/24 VDC (0.1 A) Transistor output (source type) 1-wire type Terminal block typeOutput 16 points: 12/24 VDC (0.1 A) Transistor output (source type) 1-wire type Terminal block typeOutput 16 points: 12/24 VDC (0.5 A) Transistor output (source type) 1-wire type Terminal block typeOutput 32 points: 12/24 VDC (0.5 A) Transistor output (source type) 1-wire type Terminal block typeOutput 8 points: 24 VDC/240 VAC (2 A) Relay output 2-wire type Terminal block typeOutput 16 points: 24 VDC/240 VAC (2 A) Relay output 2-wire type Terminal block typeOutput 8 points: 100 to 240 VAC (0.6 A) Triac output 2-wire type Terminal block typeOutput 16 points: 100 to 240 VAC (0.6 A) Triac output 2-wire type Terminal block typeInput 4 points: 24 VDC (positive common) 3-wire type Response time 1.5 msOutput 4 points: 24 VDC(0.5 A) Transistor output (sink type) 2-wire type Terminal block typeInput 4 points: 24 VDC (positive common) 3-wire type Response time 1.5 msOutput 4 points: 24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block type(low-leakage current type)Input 8 points: 24 VDC (positive common)1-wire type Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeInput 8 points: 24 VDC (positive common)1-wire type High-speed response Response time 0.2 msOutput 8 points: 24 VDC (0.5 A)Transistor output (sink type) 1-wire type Terminal block typeinput 8 points: 24 VDC (positive common) 1-wire type Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Input 8 points: 24 VDC (positive common) 1-wire type High-speed response Response time 0.2 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Input 8 points: 24 VDC (positive common) 3-wire type Response time 1.5 msOutput 8 points: 24 VDC(0.5 A)Transistor output(sink type)2-wire type Terminal block typeInput 8 points: 24VDC (positive common) 3-wire type Response time 1.5 msOutput 8 points: 24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block type (low-leakage current type)Input16 points: 24 VDC (positive common) 1-wire type Response time 1.5 msOutput16 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeInput16 points: 24 VDC (positive common) 1-wire type High-speed response Response time 0.2 msOutput16 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeInput16 points: 24 VDC (positive common) 1-wire type Response time 1.5 msOutput16 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Input16 points: 24 VDC (positive common) 1-wire type High-speed response Response time 0.2 msOutput16 points: 24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block type (low-leakage current type)Input16 points: 24 VDC (negative common) 1-wire type High-speed response Response time 1.5 msOutput16 points: 24 VDC (0.5 A) Transistor output (source type) 1-wire type Terminal block typeInput16 points: 24 VDC (positive common/negative common shared type) 1-wire type Terminal block type Response time 10 msInput16 points: 24 VDC (positive common/negative common shared type) 2-wire type Terminal block type Response time 10 msOutput16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 1-wire type Terminal block typeOutput16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire type Terminal block typeOutput16 points: 24 VDC/240 VAC (2 A) Relay output 2-wire type Terminal block typeInput 8 points: 24 VDC (positive common) Response time 10 msOutput 8 points: 12/24 VDC (0.5A) Transistor output (sink type) 1-wire type Terminal block typeInput 8 points: 24 VDC (positive common) Response time 10 msOutput 8 points: 12/24 VDC (0.5 A)Transistor output (sink type) 2-wire type Terminal block type Input 8 points: 24 VDC (positive common/negative common shared type) Response time 10 msOutput 8 points: 24 VDC/240 VAC (2 A) Relay output 2-wire type Terminal block type Input16 points: 24 VDC/5 mA (positive common type) 2-wire type Response time 1.5 msInput32 points: 24 VDC/5 mA (positive common type) 2-wire type Response time 1.5 msOutput16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire typeOutput32 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire typeInput 8 points: 24 VDC/5 mA (positive common type) 2-wire type Response time 10.1 msOutput 8 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire typeInput 16 points: 24 VDC/5 mA (positive common type) 2-wire type Response time 10.1 msOutput 16 points: 12/24 VDC (0.5 A) Transistor output (sink type) 2-wire typeInput 8 points: 24 VDC/5 mA (positive common type) 3-wire type Response time 1.5 msInput 16 points: 24 VDC/5 mA (positive common type) 3-wire type Response time 1.5 msInput 32 points: 24 VDC/5 mA (positive common type) 3-wire type Response time 1.5 ms
Model name
AJ61BT11A1SJ61BT11AJ61QBT11A1SJ61QBT11QJ61BT11NFX2N-16CCL-MAJ65SBTB2N-8AAJ65SBTB2N-16AAJ65SBTB1-8DAJ65SBTB3-8DAJ65SBTB1-16DAJ65SBTB1-16D1AJ65SBTB3-16DAJ65SBTB1-32DAJ65SBTB1-32D1AJ65SBTB1-8TAJ65SBTB1-8T1AJ65SBTB2-8TAJ65SBTB2-8T1AJ65SBTB1-16TAJ65SBTB1-16T1AJ65SBTB2-16TAJ65SBTB2-16T1AJ65SBTB1-32TAJ65SBTB1-32T1AJ65SBTB1-8TEAJ65SBTB1-16TEAJ65SBTB1B-16TE1AJ65SBTB1-32TE1AJ65SBTB2N-8RAJ65SBTB2N-16RAJ65SBTB2N-8SAJ65SBTB2N-16S
AJ65SBTB32-8DT
AJ65SBTB32-8DT2
AJ65SBTB1-16DT
AJ65SBTB1-16DT1
AJ65SBTB1-16DT2
AJ65SBTB1-16DT3
AJ65SBTB32-16DT
AJ65SBTB32-16DT2
AJ65SBTB1-32DT
AJ65SBTB1-32DT1
AJ65SBTB1-32DT2
AJ65SBTB1-32DT3
AJ65SBTB1-32DTE1
AJ65BTB1-16DAJ65BTB2-16DAJ65BTB1-16TAJ65BTB2-16TAJ65BTB2-16R
AJ65BTB1-16DT
AJ65BTB2-16DT
AJ65BTB2-16DR
AJ65VBTS3-16DAJ65VBTS3-32DAJ65VBTS2-16TAJ65VBTS2-32T
AJ65VBTS32-16DT
AJ65VBTS32-32DT
AJ65VBTCE3-8DAJ65VBTCE3-16DAJ65VBTCE3-32D * Positive common: sink, negative common: source
Voltage/current input
Temperature input
Voltage/current outputVoltage outputCurrent outputVoltage inputCurrent inputVoltage output
CC-Link Related Product Model Names
Thin, waterproof type repeater hub moduleSpring clamp terminal block type repeater hub moduleRepeater (T-branch) module
Optical repeater module
Spatial opticalrepeater module
231 232
233
Product Name Model nameSpecifications
Product Name Model name Specifications
Plug colorTransparent
YellowRedBlue
Applicable cable core (mm2)0.14 to 0.2
(AWG #26 to 24)0.3 to 0.5
(AWG #22 to 20)
Applicable cable outside diameter (mm)1.0 to 1.4 mm dia.1.4 to 2.0 mm dia.1.0 to 1.4 mm dia.1.4 to 2.0 mm dia.
A6CON-P214A6CON-P220A6CON-P514A6CON-P520
A6CON-L5P
A6CON-PW5P
A6CON-PW5P-SOD
A6CON-TR11
Immediate installation connector plugs(20pcs)
Immediate installation connector plugs for communication (10pcs)
Immediate installation connector plugs for power supply/FG(10pcs)
Immediate installation connector plugs w/ terminator (1pcs)
Immediate installation connector type for communication 5-pin [transmission circuit terminal (pressure welding type)]Applicable cable: FANC-110SBH (made by Kurashiki Denko Co., Ltd.) CS10 (made by Daiden Co., Ltd.)Power supply: Immediate installation connector type for power supply 5-pin [module power supply terminal, I/O power supply terminal, FG terminal (pressure welding type)]Applicable wire size: 0.66 to 0.98 mm2 (AWG18) [2.2 to 3.0 mm dia.] wire diameter 0.16 mm or morePower supply: Immediate installation connector type for power supply 5-pin [module power supply terminal, I/O power supply terminal, FG terminal (pressure welding type)]Applicable wire size: 0.66 to 0.98 mm2 (AWG18) [2.2 to 3.0 mm dia.] wire diameter 0.16 mm or moreImmediate installation connector type for communication w/ terminator (110 W)When the connector type remote I/O is used for the end station on the network, be sure to use this terminator.
Product Name Model name Applicable module
Online connector for communication (5pcs)Online connector for power supply (5pcs)
Protective cover for 8-point module (10pcs)
Protective cover for 16-point module(10pcs)
Protective cover for 32-point module(10pcs)
A6CON-LJ5P
A6CON-PWJ5P
A6CVR-8A6CVR-VCE8
A6CVR-16
A6CVR-VCE16
A6CVR-32
Online connector for communication 5-pole (10-pin)
Online connector for power supply 5-pole (10-pin)
AJ65SBTB1-8D, AJ65SBTB1-8T, AJ65SBTB1-8TE, AJ65SBT-RPTAJ65VBTCE3-8D, AJ65VBTCE2-8TAJ65SBTB1-16D, AJ65SBTB1-16D1, AJ65SBTC1-32D, AJ65SBTC1-32D1, AJ65SBTB3-8D, AJ65SBTB2-8A, AJ65SBTB2N-8A, AJ65SBTB1-16T, AJ65SBTB1-16T1, AJ65SBTC1-32T, AJ65SBTB2-8T, AJ65SBTB1-16TE, AJ65SBTB2-8R, AJ65SBTB2N-8R, AJ65SBTB2-8S, AJ65SBTB2N-8S, AJ65SBTC1-32DT, AJ65SBTC1-32DT1, AJ65SBTC4-16D, AJ65SBTC4-16DT, AJ65SBTB1-16DT, AJ65SBTB1-16DT1, AJ65SBTB32-8DT, AJ65SBT-RPG, AJ65SBT-RPSAJ65VBTCE3-16D, AJ65VBTCE2-16T, AJ65VBTCE32-16DTAJ65SBTB1-32D, AJ65SBTB1-32D1, AJ65SBTB3-16D, AJ65SBTB2-16A, AJ65SBTB2N-16A, AJ65SBTB1-32T, AJ65SBTB1-32T1, AJ65SBTB2-16T, AJ65SBTB2N-16R, AJ65SBTB2-16S, AJ65SBTB2N-16S, AJ65SBTB1-32DT, AJ65SBTB1-32DT1, AJ65SBTB32-16DT
Product Name Model name SpecificationsDustproof cap (20pcs)
Waterproof cap (20pcs)
A6CAP-DC1A6CAP-WP1A6CAP-WP2
For unused connector protective cap, dustproof dedicated (not IP67-compatible)For unused connector protective cap, waterproof protective structure: IP67-compatible, applicable for AJ65SBTW I/O moduleFor unused connector protective cap, waterproof protective structure: IP67-compatible, applicable for AJ65SFBTA I/O module
Product Name Model name Specifications40-pin connector(FCN connector)(1pcs)
A6CON1A6CON2A6CON3
Soldered type (straight-out type)Pressure welding type (straight-out type)Pressure welding type (flat cable type)
Immediate installation connector type
Protective cover for remote I/O module
Online connector
Unused connector protective cap
40-pin connector (FCN connector)
Module mounting fixture Product Name Model name Applicable module
Module mounting fixture (5pcs)
A6PLT-J65V1A6PLT-J65V2
AJ65VBTCU3-8D1, AJ65VBTCU2-8T, AJ65VBTCU3-16DT, AJ65VBTCU2-16T
Optional parts for I/O module
Module type
Embedded type I/O module
Embedded type interface board
Object development
Dedicated communication LSI
MFP1N
Device kit
MFP2AN
MFP2N
MFP3N
IPindication
Specifications
Input 16 points : 24 VDC (positive common) Pin header type 44-pin (2 rows) Embedded type Response time 1.5msOutput 16 points : 12/24 VDC (0.1 A) Transistor output (sink type)Pin header type 44-pin (2 rows) Imbedded typeInput 8 points : 24 VDC (positive common) Response time 1.5msOutput 8 points : 24 VDC (0.1 A) Transistor output (sink type) Pin header type 44-pin (2 rows) Imbedded typeInput 32 points : 24 VDC (positive common) Pin head type 62-pin (2 rows) Imbedded type Response time 1.5msOutput 32 points : 12/24 VDC (0.1 A) Transistor output (sink type)Pin head type 62-pin (2 rows) Imbedded typeFor CC-Link Ver.2 compatible master/local/intelligent device stationCommunication LSI for lead-free/RoHS compatible master/local/intelligent device station (60pcs)Communication LSI for lead-free/RoHS compatible master/local/intelligent device station (300pcs)For network circuit (Flash ROM x 1pc, SPLD x 2pcs)Communication LSI for lead-free/RoHS compatible remote I/O station (16 points) (60pcs)Communication LSI for lead-free/RoHS compatible remote I/O station (16 points) (300pcs)Communication LSI for lead-free/RoHS compatible remote I/O station (32 points) (60pcs)Communication LSI for lead-free/RoHS compatible remote I/O station (32 points) (300pcs)Communication LSI for lead-free/RoHS compatible remote device station (60pcs)Communication LSI for lead-free/RoHS compatible remote device station (300pcs)
Model name
AJ65MBTL1N-16D
AJ65MBTL1N-16T
AJ65MBTL1N-16DT
AJ65MBTL1N-32D
AJ65MBTL1N-32T
Q50BD-CCV2A6GA-CCMFP1NN60FA6GA-CCMFP1NN300FQ6KT-NPC2OG51A6GA-CCMFP2ANN 60FA6GA-CCMFP2ANN 300FA6GA-CCMFP2NN 60FA6GA-CCMFP2NN 300FA6GA-CCMFP3NN 60FA6GA-CCMFP3NN 300F
* Positive common: sink, negative common: source
234
Bridge module
Module type
Accessories
Communication connector
Cable
Terminator connector
Open sensor connector(e-CON)
Tool
CL9-CNF-18CL9-CNR-23CL9-CNR-20CL9-FL4-18CL9-MV4-075CL9-TERMCL9-RYVK
ECN-******
L-TOOL-Ne-TOOL-NKD-5339
Model name Specifications
Connector for CC-Link/LT dedicated flat cable connectionConnector for CC-Link/LT dedicated VCTF connectionConnector for CC-Link/LT dedicated flexible cable connectionCC-Link/LT dedicated flat cableCC-Link/LT dedicated flexible cableTerminator for dedicated flat cable, VCTF and dedicated flexible cableTerminator for dedicated flat cableI/O connector for sensor connector type*: The model name varies according to the connector color or wire diameterPressure welding tool for communication connectorPressure welding tool for open sensor connectorTool for spring clamp terminal block
Mitsubishi Electric Corporation
Mitsubishi Electric System & Service Engineering Co.,Ltd.
Module type
Master module
Remote I/O module
Analog module
Dedicated power supplyPower supply adapterCommunication LSI for master stationCommunication LSI for remote I/O stationCommunication LSI for remote device station
Accessories
Screw terminal block type
Spring clamp terminalblock type
Sensor connector type (e-CON)
MIL connector type
Cable type
Screw terminal block type
CLC13
CLC21
CLC31
Common terminal block
Holder
IP indicationIP2XIP2X
IP2XIP2XIP2XIP2XIP2XIP1XIP1X
IP2X
IP2X
IP1X
IP1X
IP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2XIP2X
IP2X
IP2XIP2XIP2XIP2XIP2X
IP2X
IP1XIP2X
Specifications
CC-Link/LT master module for Q SeriesCC-Link/LT master module for FX1N, FX2N, FX1NC, FX2NC
FX3UC series Micro PLC (Built-In CC-Link/LT master function)CC-Link - CC-Link/LT bridge moduleInput 4 points : 24 VDC (positive common/negative common shared)Input 8 points : 24 VDC (positive common/negative common shared)Output 4 points : 12/24 VDC (sink type) 0.1A Transistor outputOutput 8 points : 12/24 VDC (sink type) 0.1A Transistor module (w/ output protection function)Output 4 points : 30 VDC , 250 VAC or less 2A Relay outputOutput 4 points : 30 VDC , 250 VAC or less 2A Relay output 1 point 1 common (independent)Input 2 points : 24 VDC (positive common/negative common shared)Output 2 points : 12/24 VDC (sink type) 0.1A Transistor outputInput 4 points : 24 VDC (positive common/negative common shared)Output 4 points : 12/24 VDC (sink type) 0.1ATransistor outputInput 2 points : 24 VDC (positive common/negative common shared)Output 2 points : 30 VDC , 250 VAC or less (sink type) 2A Relay outputInput 4 points : 24 VDC (positive common/negative common shared)Output 4 points : 30 VDC , 250 VAC or less 2ARelay outputInput 4 points : 24 VDC (positive common/negative common shared)Input 8 points : 24 VDC (positive common/negative common shared)Output 4 points : 12/24 VDC (sink type) 0.1A Transistor outputOutput 8 points : 12/24 VDC (sink type) 0.1A Transistor outputOutput 8 points : 12/24 VDC (source type) 0.1A Transistor outputInput 4 points : 24 VDC (positive common)Input 8 points : 24 VDC (positive common)Input 16 points : 24 VDC (positive common)Output 4 points : 24 VDC (sink type) 0.1A Transistor outputOutput 8 points : 24 VDC (sink type) 0.1A Transistor module (output protection function)Output 16 points : 24 VDC (sink type) 0.1A Transistor module (output protection function)Input 8 points : 24 VDC (positive common)Output 8 points : 24 VDC (sink type) 0.1A Transistor module (output protection function)Input 16 points : 24 VDC (positive common)Output 16 points : 12/24 VDC (sink type) 0.1A Transistor module (output protection function)Output 16 points : 12/24 VDC (source type) 0.1A Transistor module (output protection function)Input 2 points : 24 VDC (positive common)Output 2 points : 24 VDC (sink type) 0.1ATransistor outputInput 1 points : 24 VDC (positive common)Output 1 points : 24 VDC (sink type) 0.1ATransistor output4-channel voltage/current input A/D conversion module (analog input module)2-channel voltage/current output D/A conversion module (analog output module)CC-Link/LT dedicated power supply (2A)Power supply adapter (5A) for CL1PAD1 CC-Link/LT
Communication LSI for lead-free/RoHS compatible master station (60pcs)
Communication LSI for lead-free/RoHS compatible remote I/O station (60pcs)Communication LSI for lead-free/RoHS compatible remote I/O station (300pcs)
Communication LSI for remote device station (60pcs)
Common terminal block for screw terminal block (applicable model: CL2X8-D1B2, CL2Y8-TP1B2)Spring clamp terminal block type common terminal block (applicable model : CL2X8-D1S2)Holder for cable type mounting (5pcs)
Model name
QJ61CL12FX2N-64CL-MFX3UC-32MT-LTAJ65SBT-CLBCL1X4-D1B2CL2X8-D1B2CL1Y4-T1B2CL2Y8-TP1B2CL1Y4-R1B2CL1Y4-R1B1
CL1XY4-DT1B2
CL1XY8-DT1B2
CL1XY4-DR1B2
CL1XY8-DR1B2
CL1X4-D1S2CL2X8-D1S2CL1Y4-T1S2CL2Y8-TP1S2CL2Y8-TPE1S2CL1X4-D1C3CL2X8-D1C3V CL2X16-D1C3VCL1Y4-T1C2CL2Y8-TP1C2V CL2Y16-TP1C2V
CL2XY16-DTP1C5V
CL2X16-D1M1V CL2Y16-TP1M1VCL2Y16-TPE1M1VCL1X2-D1D3SCL1Y2-T1D2S
CL1XY2-DT1D5S CL2AD4-BCL2DA2-BCL1PSU-2ACL1PAD1
CL2GA13-60
CL2GA21-60CL2GA21-300
CL2GA31-60
CL2TE-5CL2TE-10SCL1-HLD
Voltage/current inputVoltage/current output
CC-Link/LT related product model names
• To use the products given in this catalog properly, always read the "manuals" before starting to use them.
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
For safe useThis catalog explains the typical features and functions of the Q series PLCs and does not provide restrictions and other information on usage and module combinations. When choosing the products, always check the detailed specifications, restrictions, etc. of the products in the Q series data book. When using the products, always read the user's manuals of the products.Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
Precautions for Choosing the Products
When exported from Japan, this manual does not require application to theMinistry of International Trade and Industry for service transaction permission.
L(NA)08039E-B 0703(MDOC)New publication, effective Mar. 2007
Specifications subject to change without notice.
Open field NetworkCC-Link and CC-Link/LT Compatible product databook O
pen field Netw
ork CC
-Link and CC
-Link/LT C
ompatible product databook
Mar
2007
Top Related