7/28/2019 Catalogue Mar-Ix ENG
1/57
MAR-IX IS A PRODUCT FROM MAV B.V. WWW.MAVE.NL English
MARINE AIR-CONDITIONING, HEATING
AND VENTILATION SYSTEMS
HVAC Catalogue
7/28/2019 Catalogue Mar-Ix ENG
2/57
7/28/2019 Catalogue Mar-Ix ENG
3/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
3
CONTENTS
Self contained units 04
Airco chiller units 06
Clima chiller units 08
Airco inverter chiller units 10
Clima inverter chiller units 12
Hydraulic driven chiller units 14
Reversed cycle chiller units 16
Fan coil units 18
Defroster units 33
Air handling units 34
Accessories 36
System possibilities 39
Compositions 46
Application form 55
7/28/2019 Catalogue Mar-Ix ENG
4/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
The self contained unit is a complete air
conditioning system. It is a compact system
that can easily cool any given chamber.
This compact system includes all cool technical
components that an air-conditioning unit
requires to cool a single compartment, such as
the seawater cooled condenser, compressor
and evaporator.
This unit can be easily installed in the
compartment without being entirely visible.
Included with this system are all basic
necessary components such as the seawater
pump and the thermostat. These items are
required to secure a fully functioning air
conditioning system.
Self Contained Units
Self contained units4
- self contained unit
- manual
- sea water pump
- sea water strainer
- digital thermostat
- isolated airhose
- skin fittings
Standard supply
- equipped with rotary compressor
- filled with environment friendly R407Crefrigerant
- mainly manufactured from stainless steel
- sea water resistant condenser
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- low current
- air outlet horizontally or vertically adjustable
Technical features
* 230V/60Hz-AC on request
SCU2 SCU3
Price 1.699,- 1.865,-
Voltage
Cool capacity
Refrigerant
Current
Max. air flow
Airhose connection
Dimensions (lxwxh)
230V 50Hz-AC* and 12-24VDC
2 kW (6.800Btu)
R407C
3A
350 m/h
100 mm
447 x 216 x 354 mm
230V 50Hz-AC* and 12-24VDC
3 kW (10.200Btu)
R407C
4,5A
650 m/h
150 mm
506 x 216 x 354 mm
Weight 27 kg 31 kg
7/28/2019 Catalogue Mar-Ix ENG
5/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Self contained units 5
See page 46 for an example composition.
SCU3
3kW (10.200Btu)
SCU2
2kW (6.800Btu)
7/28/2019 Catalogue Mar-Ix ENG
6/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
An airco chiller unit is a system which can be
installed in the engine compartment.
This chiller unit supplies a tubing circuit through
the boat with cold water (glycol). This fluid
flows through the fan coil units (through which
air is flowing at the same time) and as a result
it cools the surrounding areas.
This system can cool any given area, the
temperature can be controlled and adjusted
separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the airco chiller
unit.
A complete chiller system consists of the airco
chiller unit, fan coil units and thermostats.
Airco Chiller Unit
Airco chiller units6
- the chiller unit
- manual
- circulation pump
- sea water pump
- sea water strainer
- reservoir or expansion tank
- all required fluid connectors
- skin fittings
Standard supply
- equipped with rotary compressors
- filled with environment friendly R407Crefrigerant
- mainly manufactured from stainless steel
- sea water resistant condenser
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- low current
- quiet operation
- compact system
Technical features
* 230V/60Hz-AC on request
A5 A10 A15
Voltage
Cool capacity
Refrigerant
Number of compressors
Current
Dimensions (lxwxh)
Weight
230V 50Hz-AC* and 12-24VDC
5 kW (17.000Btu)
R407C
1
5A
268 x 387 x 418 mm
41 kg
230V 50Hz-AC* and 12-24VDC 230V 50Hz-AC* and 12-24VDC
10 kW (34.100Btu) 15 kW (51.200Btu)
R407C R407C
2 3
10A 15A
513 x 387 x 418 mm 758 x 387 x 418 mm
79 kg 115 kg
Price 3.610,- 5.135,- 6.870,-
7/28/2019 Catalogue Mar-Ix ENG
7/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Airco chiller units 7
A10
10kW (34.100Btu)
A1515kW (51.200Btu)
A5
5kW (17.000Btu)
See page 47 for an example composition.
7/28/2019 Catalogue Mar-Ix ENG
8/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
A clima chiller unit is a system which can be
installed in the engine compartment.
This chiller unit supplies a tubing circuit through
the boat with cold or warm water (glycol). This
fluid flows through the fan coil units (through
which air is flowing at the same time) and as a
result it can either cool down or heat up the
surrounding areas.
This system can control the temperature in any
given compartment separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the clima chiller
unit.
The integrated diesel heater is the main source
for heating the system.
A complete chiller system consists of the clima
chiller unit, fan coil units and thermostats.
Clima Chiller Unit
Clima chiller units8
- the chiller unit
- manual
- circulation pump
- sea water pump
- sea water strainer
- reservoir or expansion tank
- all required fluid connectors
- skin fittings
Standard supply
- equipped with rotary compressors
- filled with environment friendly R407Crefrigerant
- mainly manufactured from stainless steel
- sea water resistant condenser
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- low current
- quit operation
- compact system
Technical features
* 230v/60Hz-ac on request
C5 C10 C15
Voltage
Cool capacity
Refrigerant
Number of compressors
Current AC
Heat capacity
Current DC
230V 50Hz-AC* and 12-24VDC
5 kW (17.000Btu)
R407C
1
5A
5 kW (diesel)
10-37W
230V 50Hz-AC* and 12-24VDC 230V 50Hz-AC* and 12-24VDC
10 kW (34.100Btu) 15 kW (51.200Btu)
R407C R407C
2 3
10A 15A
9 kW (diesel) 9 kW (diesel)
36-125W 36-125W
Dimensions (lxwxh)
Weight
268 x 387 x 511 mm
45 kg
513 x 514 x 418 mm 758 x 514 x 418 mm
90 kg 130 kg
Price 5.400,- 7.145,- 8.920,-
7/28/2019 Catalogue Mar-Ix ENG
9/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Clima chiller units 9
C10
Koel vermogen 10kW (34.100Btu)
Verwarmend vermogen 10kW
C15
Koel vermogen 15kW (51.200Btu)Verwarmend vermogen 10kW
C5
Koel vermogen 5kW (17.000Btu)
Verwarmend vermogen 5kW
Zie pagina 48 voor een voorbeeld samenstelling.
7/28/2019 Catalogue Mar-Ix ENG
10/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
An airco inverter chiller unit is a system which
can be installed in the engine compartment.
This chiller unit will control its capacity
according to what is being demand in its
surroundings, due to the applied inverter
compressor technology.
There is no current peak when switching on the
compressor.
The chiller unit supplies cold water (glycol)which flows through a tubing circuit and fan coil
units, (through which air is flowing at the same
time) and as a result it cools the surrounding
areas.
This system can cool any given area/cabin and
the temperature and airflow can be controlled
and adjusted separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the chiller unit.
A complete system consists of the chiller unit,
fan coil units and thermostats.
Airco Inverter Chiller Units
Airco inverter chiller units10
- the chiller unit
- manual
- circulation pump
- sea water pump
- sea water strainer
- all required fluid connectors
- skin fittings
Standard supply
- equipped with variable capacity rotary
compressor- filled with environment friendly R410A
refrigerant
- mainly manufactured from stainless steel
- sea water resistant condensor
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- low current
- quit operation
- variable cool capacity
- compact system
- no current peak at start-up- energy saving
Technical features
AIV5 AIV8 AIV10
Voltage
Cool capacityRefrigerant
Current
Dimensions (lxwxh)
Weight
230V 50/60Hz-ACand 12-24VDC
R407C
1,5-5A
508 x 257 x 414 mm
39 kg
1-5kW (3.400-17.000Btu)
230V 50/60Hz-ACand 12-24VDC
R410A
2-10A
408 x 387 x 445 mm
47 kg
2-10kW (6.800-34.100Btu)
230V 50/60Hz-ACand 12-24VDC
R410A
2-8A
508 x 257 x 474 mm
48 kg
2-8kW (6.800-27.300Btu)
Price 4.900,- 5.985,- 5.620,-
AIV15
230V 50/60Hz-ACand 12-24VDC
R410A
3-15A
578 x 377 x 515 mm
68 kg
2-15kW (6.800-51.200Btu)
8.100,-
AIV25
380-440V 50/60HzL3+N+Pe and 12-24VDC
R410A
9A / 400V
678 x 457 x 597 mm
110 kg
4-25kW (13.600-85.300Btu)
14.900,-
Voltage
Cool capacity
Refrigerant
Current
Dimensions (lxwxh)
WeightPrice
AIV20
380-440V 50/60HzL3+N+Pe and 12-24VDC
R410A
7,5A / 400V
678 x 457 x 597 mm
108 kg
4-20kW (13.600-68.300)
13.700,-
AIV30
380-440V 50/60HzL3+N+Pe and 12-24VDC
R410A
11A / 400V
678 x 457 x 597 mm
114 kg
4-30kW (13.600-102.300)
15.600,-
7/28/2019 Catalogue Mar-Ix ENG
11/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Airco inverter chiller units 11
AIV5
5kW (17.000Btu)
AIV15
15kW (51.200Btu)
AIV20/AIV25/AIV30
AIV10
10kW (34.100Btu)
AIV8
8kW (27.300Btu)
See page 49 for an example composition.
7/28/2019 Catalogue Mar-Ix ENG
12/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Clima inverter chiller units12
A clima inverter chiller is a system which can
be installed in the engine compartment.
This chiller unit will control its capacity
according to what is being demanded in its
surroundings due to the applied inverter
compressor technology.
There is no current peak when switching on
the compressor.
The chiller unit supplies cold/hot water (glycol)which flows through a tubing circuit and fan
coil units, (through which air is flowing at the
same time) and as a result it cools/heats the
surrounding areas.
This system can cool any given area/cabin,
and the temperature and airflow can be
controlled and adjusted separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the chiller unit.
Furthermore this system is equipped with a
diesel heater, heat exchanger and boiler
function. The heat exchanger can be
connected to the cooling system of the main
engine or generator, to heat the boiler or the
heating system. The boiler function can be
connected to the diesel heater or heat
exchanger, and is able to function
simultaniously with the cooling function.
A complete system consists of the chiller unit,
fan coil units and thermostats.
Clima Inverter Chiller Units
- the chiller unit
- manual
- circulation pump
- sea water pump
- sea water strainer
- reservoir or expansion tank
- all required fluid connectors
- skin fittings
Standard supply
- equipped with variable capacity rotary
compressor- filled with environment friendly R410A
refrigerant
- mainly manufactured from stainless steel
- sea water resistant condensor
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- low current
- quit operation
- variable cool capacity
- compact system
- no current peak at start-up- energy saving
Technical features
Voltage
Cool capacity
Refrigerant
Number of compressors
Current AC
Heat capacity
Current DC
Dimensions (lxwxh)
WeightPrice
CIV15230V 50/60Hz-AC
and 12-24VDC
3-15 kW(10.200-51.200Btu)
R410A
1
3-15A
10 kW
36-125W
578 x 517 x 515 mm
88 kg 9.830,-
CIV10-10230V 50/60Hz-AC
and 12-24VDC
2-10 kW(6.800-34.100Btu)
R410A
1
2-10A
10 kW
36-125W
408 x 606 x 435 mm
68 kg 9.100,-
CIV10-5230V 50/60Hz-AC
and 12-24VDC
2-10 kW(6.800-34.100Btu)
R410A
1
2-10A
5 kW
10-37W
408 x 501 x 445 mm
62 kg 8.600,-
CIV8230V 50/60Hz-AC
and 12-24VDC
2-8 kW(6.800-27.300Btu)
R410A
1
2-9A
5 kW
10-37W
508 x 371 x 474 mm
61 kg 7.240,-
CIV5230V 50/60Hz-AC
and 12-24VDC
1-5 kW(3.400-17.000Btu)
R407C
1
1,5-5A
5 kW
10-37W
508 x 371 x 414 mm
52 kg 6.520,-
7/28/2019 Catalogue Mar-Ix ENG
13/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Clima inverter chiller units 13
CIV5
Cool capacity 5kW (17.000Btu)
Heat capacity 5kW
CIV8
Cool capacity 8kW (27.300Btu)
Heat capacity 5kW
CIV10
Cool capacity 10kW (34.100Btu)
Heat capacity 5kW or 10kW
CIV15
Cool capacity 15kW (51.200Btu)
Heat capacity 10kW
See page 50 for an example composition.
7/28/2019 Catalogue Mar-Ix ENG
14/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
The hydraulic driven chiller unit is a system
which can be placed in the engine room.
This chiller unit is equipped with a hydraulic
driven cool compressor, circulation pump and
sea water pump (intergrated).
The system is driven by a hydraulic installation
(usually already present on board) and a
battery supply of 24VDC.
This chiller unit supplies a tubing circuit throughthe boat with cold water (glycol). This fluid
flows through the fan coil units (through which
air is flowing at the same time) and as a result
it cools the surrounding areas.
This system can cool any given area/cabin,
and the temperature and airflow can be
controlled and adjusted separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the chiller unit.
A complete chiller system consists of the
hydraulic driven chiller unit,
fan coil units and thermostats.
Hydraulic Driven Chiller Units
- the hydraulic driven chiller unit
- manual
- the hydraulic driven circulation pump
(intergrated)
- the hydraulic driven sea water pump
(intergrated)
- sea water strainer
- reservoir or expansion tank
- all required fluid connectors
- skin fittings
Standard supply
- equipped with hydraulic driven compressor,
circulation and sea water pump- filled with environment friendly R134A
refrigerant
- mainly manufactured from stainless steel
- sea water resistant condenser
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- compact system
- resistant against rough seas and angles up
to 60
Technical features
* 12VDC on request
HC5 HC10
Price 9.320,- 11.900,-
Voltage
Cool capacity
Refrigerant
Current
Oil supply
Dimensions (lxwxh)
24VDC*
5kW (17.000Btu)
R134A
1
3A
8-12L/min. (at 150bar)
250 x 460 x 515 mm
24VDC*
10kW (34.100Btu)
R134A
1
3A
10-15L/min (at 150bar)
260 x 600 x 663 mm
Weight 40 kg 76 kg
Specially
designedf
orextrem
e
circumsta
nces!
14 Hydraulic driven chiller units
Number of compressors
7/28/2019 Catalogue Mar-Ix ENG
15/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
HC10
Cool capacity 10kW (34.100Btu)
HC5
Cool capacity 5kW (17.000Btu)
15Hydraulic driven chiller units
See page 51 for an example composition.
7/28/2019 Catalogue Mar-Ix ENG
16/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
A reversed cycle chiller unit is an alternative
current (AC) system (with Reverse Cycle
heating system) which can be installed in the
engine compartment.
This chiller unit supplies a tubing circuit
through the boat with cold or warm water
(glycol). This fluid flows through the fan coil
units (through which air is flowing at the same
time) and as a result it cools down or heats up
the surrounding areas.
This system can control the temperature in
any given compartment separately.
The sum of the capacity of the fan coil units,
which have to function at the same time,
results in the total capacity of the chiller unit.
A complete chiller system consists of the
reversed cycle chiller unit, fan coil units and
thermostats.
Reversed Cycle Chiller Units
Reversed cycle chiller units16
- the chiller unit
- manual
- circulation pump
- sea water pump
- sea water strainer
- expansion tank
- all required fluid connectors
- skin fittings
Standard supply
- equipped with scroll compressors
- filled with environment friendly R407Crefrigerant
- mainly manufactured from stainless steel
- sea water resistant condensor
- sea water resistant water pump
- standard equipped with vibration absorbers
- pressure and temperature protected
- quiet operation
- reverse cycle heating system
Technical features
A15RC A30RC A45RC
* 400v/60Hz-ac on request
Voltage
Cool capacity
Refrigerant
Current
Heat capacity
Dimensions (lxwxh)
Weight
400v 50Hz*L3+N+Pe and 12-24VDC
15 kW (51.200Btu)
R407C
3.600W
up to 20kW
412 x 660 x 570 mm
105 kg
400v 50Hz*L3+N+Pe and 12-24VDC
400v 50Hz*L3+N+Pe and 12-24VDC
30 kW (102.400Btu) 45 kW (153.600Btu)
R407C R407C
7.200W 10.800W
up to 40kW up to 60kW
779 x 660 x 570 mm 1.146 x 660 x 570 mm
205 kg 300 kg
Price 7.795,- 12.550,- 15.180,-
7/28/2019 Catalogue Mar-Ix ENG
17/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Reversed cycle chiller units 17
A45RC
Cool capacity 45kW (153.600Btu)
Heat capacity up to 60kW
A30RC
Cool capacity 30kW (102.400Btu)
Heat capacity up to 40kW
A15RC
Cool capacity 15kW (51.200Btu)
Heat capacity up to 20kW
See page 52 for an example composition.
7/28/2019 Catalogue Mar-Ix ENG
18/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Fan coil units are the components in a heating
and airconditioning system that ensures the
transport of energy from hot or cold air.
The MAR-IX fan coil units are designed as
compact as possible to minimize the
installation space.
The low profile (LP) range is designed to be
installed in narrow spaces. For example
vertically in cabinets or horizontally under
seating areas.
The fans used on the units are specially
selected to move a large volume of air at low
noise to guarantee comfort.
Besides the standard fan coil units it is
possible to provide the units with a 24VDC
fan, an electric 3-way valve or electric
heating.
Fan Coil Units - compact format
- rotatable fan housing- installation friendly
- high air flow air filter
- quiet operation
- low current
- external electronic device
Available with;
- 3-way valve 230VAC or 24VDC
- electric heating
- 1,5kW (5.800Btu) up to 13kW (40.200Btu)
Technical features
- the fan coil unit
- manual
- air filter
- electronic connection device
Standard supply
24 Equipped with 24VDC fan
V Equipped with electric 3-way valve
EL Equipped with electric heating
Explanation type numbers
Fan coil units18
1.5kW (5.800Btu) page 192kW (6.800Btu) page 20
2kW LP (6.800Btu) page 21
3kW (10.200Btu) page 22
3kW LP (10.200Btu) page 23
2x2kW (13.600Btu) page 24
4kW (13.600Btu) page 25
4kW LP (10.200Btu) page 26
5kW (17.000Btu) page 27
6kW (20.400Btu) page 28
7kW (23.800Btu) page 29
8kW (27.200Btu) page 30
10kW (34.00Btu) page 31
13kW (44.200Btu) page 32
Contents fan coil units
7/28/2019 Catalogue Mar-Ix ENG
19/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
10 kg 9 kg 14 kg
885,- 840,- 1.060,- 1.240,-
FC1.5 V-24 FC1.5 ELV FC1.5 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
1,5kW (5.100Btu)
4kW (80C water)
-
140 mm
310 m/h
100 mm
310 x 230 x 300
1,5kW (5.100Btu)
4kW (80C water)
0,75kW
140 mm
310 m/h
100 mm
310 x 230 x 300
1,5kW (5.100Btu)
4kW (80C water)
0,75kW
140 mm
310 m/h
100 mm
310 x 230 x
Weight 7,5 kg 9 kg 9 kg
FC1.5 FC1.5 - 24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
1,5kW (5.100Btu)
4kW (80C water)
-
140 mm
310 m/h
100 mm
270 x 210 x 300 mm
5,5 kg
1,5kW (5.100Btu)
4kW (80C water)
-
140 mm
310 m/h
100 mm
270 x 210 x 300 mm
5,5 kg
140 mm
310 m/h
100 mm
310 x 230 x 300
7,5 kgPrice 570,- 690,- 793,-
Voltage 230VAC 50/60Hz 24VDC
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 2,5A 3,7A 5,7A
Current 0,5A 2,5A 0,5A
Price 915,- 878,- 998,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC1.5 V1,5kW (5.100Btu)
4kW (80C water)
-
230VAC 50/60Hz
Fan coil units 19
FC1.5 ELV
Fan Coil Units 1.5kW
7/28/2019 Catalogue Mar-Ix ENG
20/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC2 V-24 FC2 ELV FC2 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
380 x 230 x 300
2kW (6.800Btu)
6kW (80C water)
1kW
140 mm
350 m/h
100 mm
380 x 230 x 300
2kW (6.800Btu)
6kW (80C water)
1kW
140 mm
350 m/h
100 mm
380 x 230 x 300
Weight 8,4 kg 9,9 kg 9,9 kg
FC2 FC2 - 24 FC2 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
340 x 210 x 300 mm
6,4 kg
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
340 x 210 x 300 mm
6,4 kg
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
380 x 230 x 300
8,4 kgPrice 620,- 740,- 845,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 2,5A 4,8A 6,8A
Surrent 0,5A 2,5A 0,5A
Price 965,- 928,- 1.048,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC2
FC2 ELV
Fan coil units20
Fan Coil Units 2kW
7/28/2019 Catalogue Mar-Ix ENG
21/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC2LP FC2LP - 24 FC2LP VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
340 x 160 x 510
8,3 kg
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
340 x 160 x 510
8,3 kg
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
380 x 160 x 510
10,3 kgPrice 840,- 960,- 1.163,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Current 0,5A 2,5A 0,5A
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
2kW (6.800Btu)
6kW (80C water)
-
140 mm
350 m/h
100 mm
380 x 160 x 510
10,3 kg 1.055,-
24VDC
2,5A
G O.D.
FC2LP V-24
FC2LP V
Fan coil units 21
Fan Coil Units 2kW low profile
7/28/2019 Catalogue Mar-Ix ENG
22/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC3 V-24 FC3 ELV FC3 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
480 x 250 x 320
3kW (10.200Btu)
10kW (80C water)
1,5kW
220 mm
650 m/h
150 mm
480 x 250 x 320
3kW (10.200Btu)
10kW (80C water)
1,5kW
220 mm
650 m/h
150 mm
480 x 250 x 320
Weight 11,3 kg 12,8 kg 12,8 kg
FC3 FC3 - 24 FC3 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
440 x 210 x 340 mm
9,3 kg
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
440 x 210 x 340 mm
9,3 kg
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
480 x 250 x 320
11,3 kgPrice 810,- 960,- 1.033,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 4,4A 7A 10,9A
Current 0,5A 4,4A 0,5A
Price 1.185,- 1.118,- 1.238,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC3 ELV
FC3 ELV
Fan coil units22
Fan Coil Units 3kW
7/28/2019 Catalogue Mar-Ix ENG
23/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC3LP FC3LP - 24 FC3LP VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
440 x 170 x 630 mm
13,7 kg
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
440 x 170 x 630
13,7 kg
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
480 x 170 x 630
15,7 kgPrice 1.060,- 1.210,- 1.383,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Current 0,5A 4,4A 0,5A
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
3kW (10.200Btu)
10kW (80C water)
-
220 mm
650 m/h
150 mm
480 x 170 x 630
15,7 kg 1.503,-
24VDC
4,4A
G O.D.
FC3LP V-24
Fan coil units 23
Fan Coil Units 3kW low profile
FC3LP
7/28/2019 Catalogue Mar-Ix ENG
24/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC2x2 V-24 FC2x2 ELV FC2x2 ELV-24Cool capacity
Heat capacity
Elec. Heat capacity
Type fan
Max. airflow
Airhose connectioon
Dimensions (lxwxh)
4kW (13.600Btu)
12kW (80C water)
-
2 x 140mm
2 x 350 m/h
2 x 100 mm
605 x 230 x 300
4kW (13.600Btu)
12kW (80C water)
2kW
2 x 140mm
2 x 350 m/h
2 x 100 mm
605 x 230 x 300
4kW (13.600Btu)
12kW (80C water)
2kW
2 x 140mm
2 x 350 m/h
2 x 100 mm
605 x 230 x 300
Weight 12 kg 15 kg 15 kg
FC2x2 FC2x2 - 24 FC2x2 VCool capacity
Heat capacity
Elec. Heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
4kW (13.600Btu)
12kW (80C water)
-
2 x 140mm
2 x 350 m/h
2 x 100 mm
565 x 210 x 300 mm
10 kg
4kW (13.600Btu)
12kW (80C water)
-
2 x 140mm
2 x 350 m/h
2 x 100 mm
565 x 210 x 300 mm
10 kg
4kW (13.600Btu)
12kW (80C water)
-
2 x 140mm
2 x 350 m/h
2 x 100 mm
605 x 230 x 300
12 kgPrice 885,- 1.125,- 1.108,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 5A 9,6A 13,6A
Current 1A 5A 1A
Price 1,348,- 1.278,- 1.518,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC2x2 V
Fan coil units24
Fan Coil Units 2x2kW
FC2x2 V
7/28/2019 Catalogue Mar-Ix ENG
25/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC4 V-24 FC4 ELV FC4 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
555 x 290 x 330
4kW (13.600Btu)
15kW (80C water)
2kW
225 mm
850 m/h
180 mm
555 x 290 x 330
4kW (13.600Btu)
15kW (80C water)
2kW
225 mm
850 m/h
180 mm
555 x 290 x 330
Weight 14,5 kg 16 kg 16 kg
FC4 FC4 - 24 FC4 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
510 x 240 x 350 mm
12,5 kg
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
510 x 240 x 350 mm
12,5 kg
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
555 x 290 x 330
14,5 kgPrice 915,- 1.115,- 1.125,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 4A 9,6A 12,7A
Current 0,9A 4A 0,9A
Price 1.340,- 1.223,- 1.343,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connectioon 16 mm 16 mm G O.D.
Airhose connectioon
Fan coil units 25
Fan Coil Units 4kW
FC4 ELV
FC4 ELV
7/28/2019 Catalogue Mar-Ix ENG
26/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC4LP FC4LP - 24 FC4LP VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
500 x 180 x 645 mm
17 kg
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
500 x 180 x 645 mm
17 kg
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
550 x 180 x 645
19 kgPrice 1.240,- 1.440,- 1.563,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Current 0,9A 4A 0,9A
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
4kW (13.600Btu)
15kW (80C water)
-
225 mm
850 m/h
180 mm
550 x 180 x 645
19 kg 1.687,-
24VDC
4A
G O.D.
FC4LP V-24
Fan coil units26
Fan Coil Units 4kW low profile
FC4LP (horizontal)
7/28/2019 Catalogue Mar-Ix ENG
27/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC5 V-24 FC5 ELV FC5 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
dimensions (lxwxh)
5kW (17.000Btu)
18kW (80C water)
-
225 mm
850 m/h
180 mm
540 x 320 x 330
5kW (17.000Btu)
18kW (80C water)
3kW
225 mm
850 m/h
180 mm
540 x 320 x 330
5kW (17.000Btu)
18kW (80C water)
3kW
225 mm
850 m/h
180 mm
540 x 320 x 330
Weight 15,7 kg 17,2 kg 17,2 kg
FC5 FC5 - 24 FC5 V
Type fan
Max. luchtopbrengst
Dimensions (lxwxh)
Weight
225mm
850 m p/u
180 mm
500 x 260 x 330
13,7 kg
225mm
850 m p/u
180 mm
500 x 260 330
13,7 kg
225mm
850 m p/u
180 mm
540 x 320 x 330
15,7 kgPrice 1.128,- 1.248,- 1.351,-
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 4A 13,9A 17A
Opgenomen stroom 0,9A 4A 0,9A
Price 1.471,- 1.436,- 1.556,-
Fluid connection G O.D. G O.D. G O.D.
Vloeistof aansluiting 16 mm 16 mm G O.D.
Luchtslang aansluiting
Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
5kW (17.000Btu)
18kW (80C water)
-
225 mm
850 m/h
180 mm
5kW (17.000Btu)
18kW (80C water)
-
225 mm
850 m/h
180 mm
5kW (17.000Btu)
18kW (80C water)
-
225 mm
850 m/h
180 mm
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Current 0,9A 4A 0,9A
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC5
FC5 (upper outlet)
Fan coil units 27
Fan Coil Units 5kW
7/28/2019 Catalogue Mar-Ix ENG
28/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC6 V-24 FC6 ELV FC6 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
6kW (20.400Btu)
20kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 150mm
720 x 250 x 320
6kW (20.400Btu)
20kW (80C water)
3kW
2 x 220 mm
2 x 650 m/h
2 x 150mm
720 x 250 x 320
6kW (20.400Btu)
20kW (80C water)
3kW
2 x 220 mm
2 x 650 m/h
2 x 150mm
720 x 250 x 320
Weight 15,5 kg 18,5 kg 18,5 kg
FC6 FC6 - 24 FC6 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
6kW (20.400Btu)
20kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 220mm
680 x 200 x 320
13,5 kg
6kW (20.400Btu)
20kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 220mm
680 x 200 x 320
13,5 kg
6kW (20.400Btu)
20kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 220mm
720 x 250 x 320
15,5 kgPrice 1.354,- 1.594,- 1.579,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 8,8A 14A 21,8A
Current 1A 8,8A 1A
Price 1.817,- 1.747,- 1.987,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC6
FC6
Fan coil units28
Fan Coil Units 6kW
7/28/2019 Catalogue Mar-Ix ENG
29/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC7 V-24 FC7 ELV FC7 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
7kW (23.800Btu)
22kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 150mm
830 x 250 x 325
7kW (23.800Btu)
22kW (80C water)
3kW
2 x 220 mm
2 x 650 m/h
2 x 150mm
830 x 250 x 325
7kW (23.800Btu)
22kW (80C water)
3kW
2 x 220 mm
2 x 650 m/h
2 x 150mm
830 x 250 x 325
Weight 17,8 kg 20,8 kg 20,8 kg
FC7 FC7 - 24 FC7 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
7kW (23.800Btu)
22kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 150mm
790 x 200 x 325
15,8 kg
7kW (23.800Btu)
22kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 150mm
790 x 200 x 325
15,8 kg
7kW (23.800Btu)
22kW (80C water)
-
2 x 220 mm
2 x 650 m/h
2 x 150mm
830 x 250 x 325
17,8 kgPrice 1.520,- 1.760,- 1.743,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 8,8A 14A 21,8A
Current 1A 8,8A 1A
Price 1.983,- 1.685,- 2.153,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC7
Fan coil units 29
Fan Coil Units 7kW
FC7
7/28/2019 Catalogue Mar-Ix ENG
30/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC8 V-24 FC8 ELV FC8 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
8kW (27.200Btu)
25kW (80C water)
-
250 mm
1000 m/h
180 mm
565 x 300 x 380
8kW (27.200Btu)
25kW (80C water)
4kW
250 mm
1000 m/h
180 mm
565 x 300 x 380
8kW (27.200Btu)
25kW (80C water)
4kW
250 mm
1000 m/h
180 mm
565 x 300 x 380
Weight 17 kg 18,5 kg 18,5 kg
FC8 FC8 - 24 FC8 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
8kW (27.200Btu)
25kW (80C water)
-
250 mm
1000 m/h
180mm
525 x 255 x 380
15 kg
8kW (27.200Btu)
25kW (80C water)
-
250 mm
1000 m/h
180mm
525 x 255 x 380
15 kg
8kW (27.200Btu)
25kW (80C water)
-
250 mm
1000 m/h
180mm
565 x 300 x 380
17 kgPrice 1,628,- 1.748,- 1.745,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 3,6A 18A 20,6A
Current 1A 3,6A 1A
Price 2.203,- 2.185,- 2.305,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC8 ELV
Fan coil units30
Fan Coil Units 8kW
FC8
7/28/2019 Catalogue Mar-Ix ENG
31/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC10 V-24 FC10 ELV FC10 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
10kW (34.000Btu)
28kW (80C water)
-
280 mm
1100 m/h
200 mm
650 x 320 x 400
10kW (34.000Btu)
28kW (80C water)
4kW
280 mm
1100 m/h
200 mm
650 x 320 x 400
10kW (34.000Btu)
28kW (80C water)
4kW
280 mm
1100 m/h
200 mm
650 x 320 x 400
Weight 22 kg 23,5 kg 23,5 kg
FC10 FC10 - 24 FC10 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
10kW (34.000Btu)
28kW (80C water)
-
280 mm
1100 m/h
200 mm
605 x 280 x 400
20 kg
10kW (34.000Btu)
28kW (80C water)
-
280 mm
1100 m/h
200 mm
605 x 280 x 400
20 kg
10kW (34.000Btu)
28kW (80C water)
-
280 mm
1100 m/h
200 mm
650 x 320 x 400
22 kgPrice 2.110,- 2.230,- 2.333,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 2,3A 18A 19,3A
Current 1A 2,3A 1A
Price 2.455,- 2.418,- 2.538,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC10 ELV
Fan coil units 31
Fan Coil Units 10kW
FC10 ELV
7/28/2019 Catalogue Mar-Ix ENG
32/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
FC13 V-24 FC13 ELV FC13 ELV-24Cool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Airhose connection
Dimensions (lxwxh)
13kW (44.200Btu)
35kW (80C water)
-
2 x 225 mm
2 x 850 m/h
2 x 180 mm
850 x 300 x 320
13kW (44.200Btu)
35kW (80C water)
6kW
2 x 225 mm
2 x 850 m/h
2 x 180 mm
850 x 300 x 320
13kW (44.200Btu)
35kW (80C water)
6kW
2 x 225 mm
2 x 850 m/h
2 x 180 mm
850 x 300 x 320
Weight 24,5 kg 27,5 kg 27,5 kg
FC13 FC13 - 24 FC13 VCool capacity
Heat capacity
Elec. heat capacity
Type fan
Max. airflow
Dimensioons (lxwxh)
Weight
13kW (44.200Btu)
35kW (80C water)
-
2 x 225 mm
2 x 850 m/h
2 x 180 mm
805 x 260 x 320
22,5 kg
13kW (44.200Btu)
35kW (80C water)
-
2 x 225 mm
2 x 850 m/h
2 x 180 mm
805 x 260 x 320
22,5 kg
13kW (44.200Btu)
35kW (80C water)
-
2 x 225 mm
2 x 850 m/h
2 x 180 mm
850 x 300 x 320
24,5 kgPrice 2.540,- 2.780,- 2.763,-
Voltage 230VAC 50/60Hz 24VDC 230VAC 50/60Hz
Voltage 24VDC 230VAC 50/60Hz 24VDC
Current 8A 27,8A 34A
Current 1,8A 8A 1,8A
Price 3.002,- 2.933,- 3.173,-
Fluid connection G O.D. G O.D. G O.D.
Fluid connection 16 mm 16 mm G O.D.
Airhose connection
FC13 ELV
FC13 ELV
Fan coil units32
Fan Coil Units 13kW
7/28/2019 Catalogue Mar-Ix ENG
33/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Defroster Units
DF2x2 - 24Cool capacity
Heat capacity
Elec. Heat capacity
Type fan
Max. airflow
Dimensions (lxwxh)
Weight
4kW (13.600Btu)
12kW (80C water)
-
2 x 140 mm
2 x 300 m/h
2 x 100 mm
793 x 289 x 170
14,3 kg
Price 2.642,-
Voltage 24VDC
Current 5A
Fluid connection 2 x G O.D.
Airhose connection
DF4LP - 244kW (13.600Btu)
15kW (80C water)
-
225 mm
750 m/h
180 mm
216 x 616 x 772
22 kg 2.953,-
24VDC
4A
G O.D.
For safety reasons it is important that the
windows in the wheelhouse are clean. To solve
that problem, a series of defroster units has
been developed and added to the assortment of
Mar-ix.
Just warming up the air to demist the windows,
generally gives poor results, especially when
the humidity in the wheelhouse is high because
of rainy weather.
The defroster units are equipped with a dualheat exchanger which warms up the air first and
cools and dehumidifies the air. This decreases
the humidity which cleans the windows faster
and better.
With the special developped control panel, the
temperature and airflow can be set stepless.
With the dry air mode activated, the defroster
unit will dehumidify the air.
Depending on the available space, the defroster
unit can be placed behind the ceiling, to blow
the air on the windows from above or the unit
can be placed in the stearing console, to blow
the air on the windows from below.
We are pleased to advise you about the
possibilities of the system.
DF2x2 - 24
DF4LP - 24
Control panel
Defroster units 33
7/28/2019 Catalogue Mar-Ix ENG
34/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Air Handling Units
New in the assortment of Mar-ix are the air
handling units.
A serie, especially designed for marine
application, produced with sustainable materials
and a high quality finish.
Air handling units are applied to provide the
ship with fresh, conditioned air.
The systems are avalaible in a large variety of
configurations. For almost every ship we cansupply a suitable system.
Mar-ix provides the unique possibility to apply a
system with heat recovery. By placing a supply
and return unit the energy in the used air can be
recovered and added to the fresh air.
In this way a energy saving from 40% till 60%
will be achieved. The total required energy to
heat and cool the air will be decreased.
We can advise you with a full calculation to
select a suitable system.
Air handling units34
Fam Ram
Fan
Type
Max. airflow
Voltage
1
2Heat recovery
140 EC 250 EC
250 - 1600m/h
24VDC / 220-230VAC 50-60Hz
HAF
F940-60%
140 EC 250 EC
250 - 1600m/h
24 VDC / 220-230VAC 50-60Hz
HAF
40-60%
Current 0,5A - 3A 0,5A 3A
Airhose connection In 125 300 / Uit 100 - 180 In 125 300 / Uit 100 - 180
Filter
Fam 1-10
Fam 6-10
Ram 1
7/28/2019 Catalogue Mar-Ix ENG
35/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Air handling units 35
Airinlet
Conditionedair
Airoutlet
Returnair
Heat
reco
very
FanF
ilter
Heatre
cove
ry
Coolin
g
Heatin
g
Coolin
g/h
eatin
g
Ele
ctric
alhe
atin
g
FAM
Posibilities:
RAM:
F
-
+
H
R-
M
+
M
-
+
M
EH
-
+
H
R
7/28/2019 Catalogue Mar-Ix ENG
36/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Electric Water Heaters
HE3 HE7.5Heat capacity
Water temperature
Dimensions (lxwxh)
Weight
3kW
30-90C
221 x 141 x 485
4 kg
7.5kW
30-90C
221 x 141 x 937
7 kg
15kW
30-90C
221 x 141 x 937
7 kg
Price 352,- 1.270,- 1.686,-
Voltage 230VAC of 400VAC 400VAC 400VAC
Current 13A/230V of 4.5A/400V 11A/400V 22A/400V
Fluid connection 2 x G O.T. 2 x G O.T. 2 x G O.T.
HE15
Accessories36
The Mar-ix electric heater gives the posibility to
heat the fluid circuit of the heating system in a
ship by electric power.
Unlike a diesel heater or a reverse cycle chiller
unit, an electric heating unit is completely silent.
The desired temperature can be preset and the
capacity can be controlled in two ways.
In the standard version, the temperature is
limited and controlled by an internal thermostat.
If the liquid temperature is reaching the setpoint
the heater will switch off, when the temperaturehas dropped to the preset level, the heater will
switch on automatically.
As an option it is possible to expand the electric
heater with an inverter system.
With this option, the output power of the heater
will be automatically adjusted to the required
capacity.
This achieves a constant heating capacity,
resulting in a constant temperature of the liquid
and equall loading of the electrical installation.
This reliable electric heater can also be used for
frost protection of the ship.The exceptional reliability is ensured because
each individual electric heater is equiped with
multiple elements. Failure of a single element
will not affect the operation of the other
elements.
HE3 HE15
7/28/2019 Catalogue Mar-Ix ENG
37/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Heat exchangers
37Accessories
Ball valve DN32 1G I.D. DN40 1G I.D.DN20 G I.D. DN25 - 1"G I.D.
2-way 3-way
24VAC/DC
230VAC
24VAC/DCMotor
Modulair
On/off
On/off
Electrical ball valve
Pumps
Circulatiepompen
SP208SP108
Voltage
Max. capacity
24VDC
45W
0,2A
230VAC
250W
1,2A
230VAC
400W
2A
Max. waterflow 1,6 m p/u 4 m p/u 8 m p/u
Max. current
MP20RZeewaterpompen SP-108 SP-208
BAC40-129
RS15/7 TOP S30-7 TOP S30-10Max. waterflow
Voltage
Max. capacity
2,5 m p/u
230VAC
125W
6,8 m p/u
230VAC
195W
10,6 m p/u
230VAC
400W
Max. current 0,55A 0,95A 1,95A
18 m p/u
230VAC
750W
2,1A
BAC40-129
Top S30-10Top S30-7
Circulatiepompen
MP20R
BPHE2x7.5 BPHE2x15
RS15/7
Mar-ix supplies heat exchangers in various
capacities and designs. These are applicable tovarious fluid systems, for separating technical
and/or heat transfer wherever desired.
These heat exchangers are often applied to use
the heat from the engines and/or generators, for
heating up the vessel and the drinking water.
7/28/2019 Catalogue Mar-Ix ENG
38/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
GrillsAir supply grill
Cherry
40,00
46,30
52,50
Mahogany
34,40
40,60
45,60
Red Oak
26,30
30,60
35,00
Walnut
28,10
32,50
37,50
Teak
51,30
58,10
65,60
Dimensions AxB
200 x 150 mm
250 x 150 mm
300 x 150 mm
Air return grill
Cherry
33,10
42,50
51,90
Mahogany
28,80
36,90
46,30
Red Oak
22,50
28,80
36,30
Walnut
23,10
30,00
38,10
Teak
41,30
51,90
63,80
Dimensions AxB
200 x 200 mm
250 x 250 mm
300 x 300 mm
L125
125 mm
145 mm
3 m
L150
150 mm
170 mm
3 m
L180
180 mm
200 mm
3 m
L200
200 mm
220 mm
3 m
L100
100 mm
120 mm
3 m
57,20 65,30 71,60 74,10 48,20
Type
Inner diameterOutside diameter
Length
Price
Air hoses Thermostaten
Type
Afmetingen (wxhxd)
Build in depth
DIGITH
120 x 90 x 30 mm
20 mm
- thermostat- manual- speed control- cables
Standard supply
Accessories38
7/28/2019 Catalogue Mar-Ix ENG
39/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
CONTENTS SYSTEM POSSIBILITIES
Clima chiller units
To cool and heat up with FC units 40
(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)
To cool and heat up with FC units including boiler function 41
(Only for the Clima inverter systems CIV series.)
To cool with FC units and heat up with radiators 42
(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)
To cool with FC units and heat up with FC units and radiators 43
(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)
To cool with FC units and heat up with radiators including boiler function 44(Only for the Clima inverter systems CIV series.)
To cool with FC units and heat up with FC units and radiators including boiler function 45
(Only for the Clima inverter systems CIV series.)
System possibilities 39
7/28/2019 Catalogue Mar-Ix ENG
40/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return
valve
Non-return
valve
Airco
HeaterM
12v
Flow circuit
during heating
To cool and heat up with FC units
40
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return
valve
Non-return
valve
Airco
HeaterM
12v
Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with anexternal heater.
7/28/2019 Catalogue Mar-Ix ENG
41/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Airco
HeaterM
12v
Flow circuit
during heating
and boiler in use
Fan coil
unit
Fan coil
unit
Fan coil
unit
Boiler
Circulation pump
Non-return
valve
To cool and heat up with FC units including boiler function
41
Cooling circuit mainengine/generator
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Boiler
Circulation pump
Non-return
valve
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Flow circuit
with boiler in use
Fan coil
unit
Fan coil
unit
Fan coil
unit
Boiler
Circulation pump
Non-return
valve
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Flow circuit
during cooling
and boiler in use
Fan coil
unit
Fan coil
unit
Fan coil
unit
Boiler
Circulation pump
Non-return
valve
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Only for the Clima inverter systems CIV series.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
7/28/2019 Catalogue Mar-Ix ENG
42/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Non-return valve
Airco
HeaterM
12v
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
Flow circuit
during heating
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Non-return valve
Airco
HeaterM
12v
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
To cool with FC units and heat up with radiators
42
Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with anexternal heater.
7/28/2019 Catalogue Mar-Ix ENG
43/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
To cool with FC units and heat up with FC units and radiators
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Non-return valve
Airco
HeaterM
12v
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Non-return valve
Airco
HeaterM
12v
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
Flow circuit
during heating
43
Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with anexternal heater.
7/28/2019 Catalogue Mar-Ix ENG
44/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
Flow circuit
during heating
and boiler in use
Flow circuit
with boiler in use
To cool with FC units and heat up with radiators including boiler function
44
Boiler
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-passBoiler
Airco
HeaterM
12v
Cooling circuit main
engine/generator
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-passBoiler
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Flow circuit
during cooling
and boiler in use
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By
-pass
By
-pass
By
-passBoiler
Airco
HeaterM
12v
Cooling circuit main
engine/generator
Only for the Clima inverter systems CIV series.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engineor generator if this is in use.
7/28/2019 Catalogue Mar-Ix ENG
45/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
To cool with FC units and heat up with FC units and radiators including boiler function
45
Flow circuit
during cooling
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-pass
Flow circuit
during heating
and boiler in use
Flow circuit
with boiler in use
Boiler
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-passBoiler
Airco
HeaterM
12v
Cooling circuit main
engine/generator
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By-pass
By-pass
By-passBoiler
Airco
HeaterM
12v
Cooling circuit mainengine/generator
Flow circuit
during cooling
and boiler in use
Fan coil
unit
Fan coil
unit
Fan coil
unit
Circulation pump
Non-return valve
Radiator Radiator Radiator
Thermostat valve Thermostat valve Thermostat valve
By
-pass
By
-pass
By
-passBoiler
Airco
HeaterM
12v
Cooling circuit main
engine/generator
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engine
or generator if this is in use.
Heat function will automatically
be supplied by the main engineor generator if this is in use.
Only for the Clima inverter systems CIV series.
7/28/2019 Catalogue Mar-Ix ENG
46/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
Example composition self contained unit installation.
Sea water strainer
Skin fitting
Ball valve
Sea water pump
Self contained unit
Skin fitting
Air return grill
Digital thermostat
Air supply grill
Isolated air hose
Example composition self contained unit installation.46
7/28/2019 Catalogue Mar-Ix ENG
47/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition airco chiller unit installation. 47
Seawaterstrainer
Skinfitting
Ballvalve
Seawate
rpump
Skinfitting
Circulationpump
Reservoir
Aircochillerunit
Fancoilunit
FC2LP
FancoilunitFC2
FancoilunitFC1.5
Digitalthermostat
FancoilunitFC3
Fanspeedcontrol
Headtubing25mmI.D.
Fan
coiltubin
g1
6mmI.D
.
Examplecompositionai
rcochillerunitinstallation.
7/28/2019 Catalogue Mar-Ix ENG
48/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition clima chiller unit installation.48
Examplecompostionclimachillerunitinstallation.
Seawaterstrainer
S
kinfitting
Ballvalve
Seawa
terpump
Skinfitting
Circulationpump
Reservoir
Climachillerunit
Fancoilunit
FC2LP
FancoilunitFC2
FancoilunitFC1.5
Digitalthermostat
FancoilunitFC3
Fanspe
edcontrol
Headtubing25mmI.D.
Fan
coil
tubin
g1
6mm
I.D
.
Exhaust
7/28/2019 Catalogue Mar-Ix ENG
49/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition airco inverter chiller unit installation. 49
Examplecompositionaircoinverterchillerunitinstallation.
Seawaterstrainer
Skinfittings
Ballvalve
Seawater
pump
Skinfittings
Circulationpump
Reservoir
Aircoinverterchillerunit
FancoilunitFC2LP
FancoilunitFC2
FancoilunitFC1.5
Digita
lthermostat
FancoilunitFC3
Fanspeedcontrol
Headtubing25mmI.D.
Fancoil
tubing
16
mmI.D
.
Digitalthermostat
Digitalthermostat
Fanspeedcontrol
Fanspeedcontrol
7/28/2019 Catalogue Mar-Ix ENG
50/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition clima inverter chiller unit installation.50
Seawaterstrainer S
kinfitting
Ballvalve
S
eawaterpump
Circulationpump
Reservoir
CIVinverterchillerunit
FancoilunitFC2LP
FancoilunitFC2
Fancoilu
nitFC1.5
Digitalthermostat
FancoilunitFC3
Headtubing25mmI.D.
Fa
ncoil
tubin
g1
6mmI.D
.
Exhaust
Digitalthermostat
Digitalthermostat
Fanspeedcontrol
Fanspeedcontrol
Fanspeed
control
Boiler
Generato
r/Mainengine
Examplecompositionclimainverterchillerunitinstallation.
7/28/2019 Catalogue Mar-Ix ENG
51/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition hydraulic driven chiller unit installation. 51
Examplecompositionhydraulicdriv
enchillerunitinstallation.
Seawaterstrainer
Skinfitting
Ballvalve
Hydropump
Oilreservoir
Reservoir
HC
chillerunit
Fancoilunit
FC2LP
FancoilunitFC2
FancoilunitFC1.5
Di
gitalthermostat
FancoilunitFC3
Fanspeedcontrol
Headtubing25mmI.D.
Fanc
oil
tubin
g1
6mm
I.D.
Skinfitting
7/28/2019 Catalogue Mar-Ix ENG
52/57
MA
RINEAIR-CONDITION
ING,
HEATINGA
ND
VENTILATION
SYSTE
MS
Example composition reversed cycle chiller unit installation.52
Examplecompositionreversedcy
clechillerunitinstallation.
Seawaterstrainer
SkinfittingB
allvalve
Seawaterpump
Skinfitting
Circulationpump
Expansiontank
RC
chillerun
it
FancoilunitFC2LP
FancoilunitFC2
FancoilunitFC1.5
Digitalthermostat
FancoilunitFC3
Fanspeedcontrol
Headtubing32-5
0mmI.D.
Fan
coiltubin
g1
6mm
I.D
.
7/28/2019 Catalogue Mar-Ix ENG
53/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
53
7/28/2019 Catalogue Mar-Ix ENG
54/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
All our systems come with 3 years full warranty!
Mentioned prices are in euros excluding V.A.T. and valid until 31 December 2012.
Prices, specifications and images are with reservations of compose, printers and type errors.
We continuously aspire improvement of our products, as a result, interim modifications may be
altered without possible notice.
Terms and conditions as per our conditions of sale (available on request).
54
7/28/2019 Catalogue Mar-Ix ENG
55/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
APPLICATION FORM
NAME
CONTACTPER
ADDRESS
POST CODE
PLACE
COUNTRY
TELEPHONE
FAX
CUSTOMER CODE
Project
Type of boat
Dimensions (lxw)
Use
System
Pleasure / Profession
Cooling / Cooling-heating
Voltage
Brand generator
Type generator
Generator capacity
Generator voltage
12v / 24v
Climate
Approval
Normal / Tropical Number of areas
Name area Place Length (m) Width (m) Hight (m)
02.
03.
04.
05.
06.
07.
08.
09.
10.
Notes:
01.
55Application form
7/28/2019 Catalogue Mar-Ix ENG
56/57
MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS
EXPLANATION FOR REQUEST FORMULAR
Explanation for request formular56
ProjectYour reference.
The type of boat gives us, together with the outside dimensions an impression of the possibillities for our
systems.
With this information we can choose a system that demands your needs, and at the same time will be as
economical as possible. Every situation can be different. Do you wish cooling in all spaces at the same time or
just in the saloon during the day and in the bedrooms at night? This information will decide the total capacity/size
of the system.
For just cooling our self contained and airco chiller units will be all you need. When a cooling and heating system
will be needed in warmer climates, than our reversed cycle chiller units will satisfy. The outside water temperature
must stay above 5 to 7 C for functioning. For climates like the Northern of Europe or other cold climates during
the winter our clima chiller systems will be satisfy. For heating these systems are provided with an Eberspcher
diesel heater. It is also possible to connect a excisting heating system onto our systems for an integral
adjustment of the digital thermostat. Also existing radiators can be connected.
Herewith we calculate an average of capacity: upper deck/ centre deck/ lower deck. Tothether with the choice of
climate we can decide the needed capacity. An upper deck cabin with a lot of windows will ask more coolingcapacity than a lower deck sleeping room.
To decide the needed capacity a cooling calculation will have to be made. The choice of climate (normal/tropical)
together with the place (upper/mid or lower deck) will give us a calculation figure.
When your situation subscribes an approved system we can take care of this.
All our systems will need a 12 or 24v-dc connection for memory and control. The 230/400v-ac 50/60Hz
connection to supply the compressors and pumps. Most of the generators are suitable for this power. If you do
not have these details please give us the brand and type of the generator.
Your defenition of the space as: saloon, sleeping room 1 /2 etc.
Type of boat (motor / sailboat) / Dimensions (lxw)
Use (pleasure / profession)
System (cooling / cooling-heating)
Place
Climate
Approval
Battery/generator details
Name area
7/28/2019 Catalogue Mar-Ix ENG
57/57
MAR-IX IS A PRODUCT FROM MAV B.V. WWW.MAVE.NL