HARMSCO® HBCPoly Coat Filter Housings
Harmsco® HBC filter housings are designed with a universal bottom plate to accept 2-1/2” or 2-3/4” diameter cartridges with DOE (double open end), 222/Flat and 222/Fin end cap configurations.
HARMSCO® Filtration Products
Ground Water RemediationProcess WaterUtility WaterWell Water
Industrial Waste Water TreatmentCooling Tower FiltrationCommercial Drinking Water
Reverse Osmosis Pre-filtration
304 stainless steel construction, standard
Universal bottom seal cups to accept DOE, 222/Flat or 222/Fin style cartridgesExterior poly coat finish, standardHeavy duty legs included on all models
Two gauge ports - inlet and outlet side
Bottom drain providedVented lid
304 stainless steel cap/spring assemblies, standard150 PSI (10.3 bar) pressure rating
Multi-Round Cartridge Housings
Options:316 stainless steel constructionAlternative O-ring material
Universal Design
Features
Applications
22R
4R / 5R
7R
12R
Filter Model Rec’d FlowRate* (GPM)
Max FlowRate* (GPM)
Max FlowRate* (LPM)
Max FlowRate* (M3/Hr)
Inlet/Outlet Connection
No. of Cartridges
Cartridge Service Height
Housing Service Ht. (in.)
Housing Wt. (lbs.)
HBC 4-1 20 28 106 6 2” MNPT 4 9-3/4” or 10” 34 37
HBC 4-2 40 56 212 13 2” MNPT 4 19-1/2” or 20” 54 41
HBC 4-3 58-60 84 318 19 2” MNPT 4 29-1/4” or 30” 74 49
HBC 4-4 80 112 424 25 2” MNPT 4 40” 94 60
HBC 5-1 25 35 132 8 2” MNPT 5 9-3/4” or 10” 34 37
HBC 5-2 50 70 265 16 2” MNPT 5 19-1/2” or 20” 54 41
HBC 5-3 75 105 397 24 2” MNPT 5 29-1/4” or 30” 74 49
HBC 5-4 100 140 530 32 2” MNPT 5 40” 94 60
HBC 7-1 35 49 185 11 2” MNPT 7 9-3/4” or 10” 35 49
HBC 7-2 70 98 371 22 2” MNPT 7 19-1/2” or 20” 55 54
HBC 7-3 105 147 556 33 2” MNPT 7 29-1/4” or 30” 75 68
HBC 7-4 138 196 742 45 2” MNPT 7 40” 95 73
HBC 12-3 178-180 252 954 57 3” Flange 12 29-1/4” or 30” 81 128
HBC 12-4 235 336 1,272 76 3” Flange 12 40” 101 139
HBC 22-3 325 462 1,749 105 4” Flange 22 29-1/4” or 30” 75 206
HBC 22-4 435 616 2,332 140 4” Flange 22 40” 95 223
Finish - Poly Coat standard (exterior only)Inlet/Outlet - 2” MNPT, 3” flange, 4” flange
Temperature - up to 250°F (121°C); filter housing only
Pressure - up to 150 PSI (10.3 bar) maxClosure - Band clamp closure, O-ring, Buna-N
Construction - 304 stainless steel standard, 316 optional
Harmsco® Poly Coat Filter Housings HBC
*Flow rates shown above are for guidelines only. Actual flow rates are based on cartridge type, micron rating, viscosity, solids content and various other factors. For complete flow and pressure drop information please refer to your cartridge manufacturer guidelines.
Note: add suffix “-6” for 316 option. Example: HBC 4-1-6 (4 round, 9-3/4” or 10” cartridge, 316 stainless steel).
Ordering Information
End Caps
Specifications
HARMSCO®
Filtration ProductsP.O. Box 14066, North Palm Beach, FL 33408(561) 848-9628 • Toll-free: (800) 327-3248 • Fax: (561) 845-2474 • E-mail: [email protected]
© Harmsco, Inc. 12E 08 7/11
www.harmsco.com
Note: This publication is to be used as a guide. The data within has been obtained from many sources and is considered to be accurate. Harmsco does not assume liability for the accuracy and/or completeness of this data. Changes to the data can be made without notification. Temperature, Pressure, Flow Rates, Differential Pressures, Chemical Combinations and other unknown factors can affect performance in unknown ways. Limited Warranty: Harmsco warrants their products to be free of material and workmanship defects. Determination of suitability of Harmsco products for uses and applications contemplated by Buyer shall be the sole responsibility of Buyer. The end user/installer/buyer shall be liable for the product’s performance and suitability regarding their specific intended applications. End users should perform their own tests to determine suitability for each application.
4R
5R
12R
7R
22R
Uses 2-1/2” or 2-3/4” O.D. Cartridges
Harmsco® HBC Cartridge Housings come standard with alternative compression / hold down plates that allow for the use of DOE, 222 / Flat or 222 / Fin end caps.
Drawings available upon request.
4R / 5R7R12R22R DOE 222 Fin
±.138.35
4
REF
16.8 B.C.LOCATED ON
9 33 3
8 "
QTY 2
"
1/2" FNPT
"8115
43 "3
90°
12"
16.70
9
45°
REF5.94
REF11.88
5.94REF
"X"
.55, QTY 3 AS SHOWN
16.8
±.25
34 "
14.34REF
1/2" FNPT
3" FLANGE1/4" FNPT
INLET
OUTLET3" FLANGE
3" FLANGE
INLET OUTLET3" FLANGE
HBC12 _POLY COAT HOUSING
12 ROUNDMULTI-CARTRIDGE
RS 7-14-11
OF HARMSCO INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT
DIMENSIONS ARE IN INCHES
+/- 30'
DESCRIPTION DATE APPROVEDREVISIONSE FILE:
DECIMALS
APPROVED
HBC 12PROPRIETARY / CONFIDENTIALREV.
SCALE
"1:8"FRACTIONS +/- 1/8
EXPRESSED WRITTEN CONSENT IS PROHIBITED.
+/- .060
PART NO.
DATEDRAWN HARMSCO INC.
P.O. BOX 14066 N. PALM BEACH, FL
DRAWN ON CAD DO NOT SCALE
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY
TOLERANCES ARE:
APPROVALS
UNLESS OTHERWISE SPECIFIED
ANGLES
DRAWING SIZE: B
STOCK MAX. CART. SERVICE CUSTOMERCODE LENGTH HEIGHT * INITIALS
HBC12-3 51" 30" 81" 20" x 19" x 56" 128 lbHBC12-4 61" 40" 101" 20" x 19" x 64" 139 lbHBC12-3-6 51" 30" 81" 20" x 19" x 56" 128 lbHBC12-4-6 61" 40" 101" 20" x 19" x 64" 139 lb* - SERVICE HEIGHT BASED ON MAXIMUM CARTRIDGE LENGTH.PORTS ARE NPT ANSI B1.20.1 UNLESS NOTED OTHERWISE.FINISH - POLY COAT, EXTERIOR ONLYO-RING MATERIAL: BUNA-NALL STOCK CODES RATED FOR 150 PSI @ 250°F MAX WORKING PRESSURE.
COMPANY:
NAME (printed):
SIGNATURE:
DATE:
CUSTOMER APPROVAL
316SS
MATERIAL"X" WEIGHTSHP. BOX SIZE
304SS
1
HBC Cartridge Filter Vessel
Installation & Service Instructions
1. Place vessel on a flat surface and secure using mounting legs. 2. Prior to install, note port labels to confirm proper flow direction (inlet/outlet). 3. Connect piping to inlet/outlet ports. 4. Loosen T-nut and remove band-clamp. 5. Open lid. 6. Inspect lid o-ring to confirm that it is free of defects and/or debris. 7. Loosen & remove hand-nut(s) from threaded rods and remove hold-
down/compression plate(s). 8. Install filter cartridges. If using DOE cartridges, place cap/spring assembly on top of
each cartridge. 9. Install hold-down/compression plate. 10. Tighten hand-nut(s) to compress springs/secure cartridges. 11. Close lid & reinstall band-clamp. 12. Tighten T-nut and confirm that band-clamp is evenly engaged around the vessel lid
(a gap of ~1/2” should remain between each of the clamp segments). 13. Close outlet valve. 14. Slowly open inlet valve to allow liquid to fill vessel. 15. Open vent valve at top of vessel- leave open until steady stream of liquid is present. 16. Close vent valve. 17. Slowly open outlet valve. 18. Open inlet valve completely. 19. Inspect lid and all port connections for leaks.
Removal of Spent Cartridges
1. Close inlet valve. 2. Open vent valve. 3. Open drain valves. 4. Loosen T-nut and remove band-clamp. 5. Open lid. 6. Loosen & remove hand-nut(s) from threaded rods and remove hold-
down/compression plate(s). 7. Remove spent filter cartridges. 8. Inspect lid o-ring to confirm that it is free of defects and/or debris. Replace if
necessary. 9. Repeat steps #8-19.
Warning/Safety
• If improperly used, pressure vessels may cause serious injury or death. • Always wear proper protective clothing for the liquid being filtered. Check your MSDS
sheets for instructions or suggestions. • Do not operate the vessel in excess of the rated pressure and/or temperature found on
the vessel label. • Confirm chemical compatibility of selected o-ring and vessel material prior to vessel
installation.
HARMSCO® BCBBand Clamp Bag Housings
Paint
Coatings
LubricantsProcess Water Solvents
Ground Water Remediation
Plating Solutions Hydraulic Fluids
Industrial Waste Water TreatmentCutting Fluids
Designed with Snap Fit “V” Ring Bag
BCB Series Bag Housings are designed for a variety of industrial filtration applications where clean effluent is critical. Offered in Extended Area bag sizes to increase contaminant removal and provide longer bag life.
Made in USAHARMSCO® Filtration Products
304 stainless steel construction, standard
Band clamp closure to simplify maintenanceInternal parts are 304 stainless steelDrill in-place legs
150 psi (10.3 bar) pressure ratingFlow rates up to 200 gpmAll filter housings hydrostatically tested
Electropolished finish, standard
Patented Extended Area replacement bags available (approx. 30% more surface area vs. Std. bags)1.5” FNPT or 2” FNPT connections available316 stainless steel perforated basket, standard
Options:316 stainless steelChemical resistant coating
BCB-1 BCB-2
Features
Applications
Commercial Grade
Harmsco® Band Clamp Bag Housings BCB
Chemical Resistant CoatingHarmsco® Band Clamp Bag Housings are available with a 3M fusion bonded epoxy coating for chemical resistance. The coating is NSF Standard 61 Certified. It is applied to all stainless steel surfaces (inside and out), and is far more resistant than 316L stainless steel. Fusion bonded epoxy coating is ideal for sea water applications and when resistance to agressive chemicals is required.
#2
B
AC
Standard #2 Bag Housing
BCB-2D
Extended #2
Basket Option
Extended #1
Basket Option
Standard #2
Basket Option
Standard #1
Basket Option
Chemical Resistant Coating Available
Finish - ElectropolishedInlet/Outlet - 1.5” FNPT or 2” FNPTConstruction - 304 stainless steel, standard; 316 stainless steel and/or chemical resistant coating, optional
Closure - O-ring Housing Seal - Buna-NTemperature - up to 250°F(121°C), housing onlyPressure - Up to 150 psi (10.3 bar)
Specifications
HARMSCO®
Filtration ProductsP.O. Box 14066, North Palm Beach, FL 33408(561) 848-9628 • Toll-free: (800) 327-3248 • Fax: (561) 845-2474 • E-mail: [email protected]
© Harmsco, Inc. 16B 10 7/11
www.harmsco.comMade in USA
Note: This publication is to be used as a guide. The data within has been obtained from many sources and is considered to be accurate. Harmsco does not assume liability for the accuracy and/or completeness of this data. Changes to the data can be made without notification. Temperature, Pressure, Flow Rates, Differential Pressures, Chemical Combinations and other unknown factors can affect performance in unknown ways. Limited Warranty: Harmsco warrants their products to be free of material and workmanship defects. Determination of suitability of Harmsco products for uses and applications contemplated by Buyer shall be the sole responsibility of Buyer. The end user/installer/buyer shall be liable for the product’s performance and suitability regarding their specific intended applications. End users should perform their own tests to determine suitability for each application.
#1
A
BC
Standard #1 Bag Housing
BCB-1D
Bag Options
Standard #1 Standard #2 (shown)Extended #1Extended #2
Standard #1 and #2 Bag Housings
Ordering Information
FilterModel
Max FlowRate*(GPM)
Max FlowRate*(LPM)
Max FlowRate*(M3/Hr)
AHeight
BDiameter
CHeight
DHeight
I/OFNPT
StandardBag Size
BCB-1-1.5-STD 90 341 20.4 28-1/4” 8” 22-3/4” 4-1/2” 1.5” 1 StdBCB-1-2-STD 90 341 20.4 28-1/4” 8” 22-3/4” 4-1/2” 2” 1 StdBCB-2-1.5-STD 200 757 45.4 42-3/4” 8” 37-1/4” 4-1/2” 1.5” 2 StdBCB-2-2-STD 200 757 45.4 42-3/4” 8” 37-1/4” 4-1/2” 2” 2 Std
FilterModel
Max FlowRate*(GPM)
Max FlowRate*(LPM)
Max FlowRate*(M3/Hr)
AHeight
BDiameter
CHeight
DHeight
I/OFNPT
ExtendedBag Size
BCB-1-1.5-EXT 90 341 20.4 28-1/4” 8” 22-3/4” 4-1/2” 1.5” 1 ExtBCB-1-2-EXT 90 341 20.4 28-1/4” 8” 22-3/4” 4-1/2” 2” 1 ExtBCB-2-1.5-EXT 200 757 45.4 42-3/4” 8” 37-1/4” 4-1/2” 1.5” 2 ExtBCB-2-2-EXT 200 757 45.4 42-3/4” 8” 37-1/4” 4-1/2” 2” 2 Ext
*Flow rates shown above are for guidelines only. Actual flow rates are based on bag type, micron rating, viscosity, solids content and various other factors. For complete flow and pressure drop information please refer to your bag manufacturer guidelines.
Extended #1 and #2 Bag Housings
1
BCB Bag Filter Vessel
Installation & Service Instructions
1. Place vessel on a flat surface and secure using mounting legs. 2. Prior to install, note port labels to confirm proper flow direction (inlet/outlet). 3. Connect piping to inlet/outlet ports. Recommended that isolation valves be installed
in inlet, and outlet ports or piping. A drain port can be created by fitting a pipe tee with a drain valve in the outlet piping between the vessel and outlet isolation valve (valves & fittings provided by others).
4. Loosen T-nut and remove band-clamp and open lid. 5. Remove ¼” NPT plug from lid vent port and install venting valve or petcock (valve
provided by others). 6. Inspect lid o-ring to confirm that it is free of defects and/or debris. 7. Remove bag basket. Inspect inside of vessel for any shipping or construction debris
and remove as needed. 8. Reinstall bag basket and install filter bag (sold separately). Flange of filter bag must
be set into the filter bag receiver ring for proper seal. 9. Close lid & reinstall band-clamp. 10. Tighten T-nut of band-clamp and confirm that band-clamp is evenly engaged around
the vessel lid (a gap of ~1/2” should remain between each of the clamp segments). 11. Close outlet valve, if open and drain valve, if installed. 12. Slowly open inlet valve to allow liquid to fill vessel. 13. Open vent valve at top of vessel, leave open until steady stream of liquid is present. 14. Close vent valve. 15. Slowly open outlet valve. 16. Open inlet valve completely. 17. Inspect lid and all port connections for leaks.
Removal of Spent Filter Bag 1. Close inlet and outlet valve. 2. Slowly open drain valve, if installed, if not use vent valve to release any pressure
inside vessel. Use caution while slowly opening valves. 3. Open vent valve and allow vessel to drain. 4. Loosen band-clamp T-nut, remove band-clamp and open lid. 5. Remove spent filter bag. 6. If drain valve is installed flush any debris inside of vessel to drain as needed. 7. Install new filter bag. Flange of filter bag must be set into the filter bag receiver ring
for proper seal. 8. Inspect lid o-ring to confirm that it is free of defects and/or debris. Replace if
necessary. 9. Repeat steps #9-17.
Warning/Safety • If improperly used, pressure vessels may cause serious injury or death. • Always wear proper protective clothing for the liquid being filtered. Check your MSDS
sheets for instructions or suggestions. • Do not operate the vessel in excess of the rated pressure and/or temperature found on
the vessel label. • Confirm chemical compatibility of selected o-ring, filter bag, and vessel material prior to