CARTESIONEONGOAGUIDEDOWNLOAD THE COMPLETECRESSI INSTRUCTION MANUALat: www.cressi.com/manuals
LONG LIFE
BATTERY
HIGH CONTRAST
DISPLAY
WIDE DIAMETER
DISPLAY
EASY ACCESS MULTI MODE
MENU
35
[ [
* Not avaible for GOA.
OPERATING BUTTONS
SCROLL DOWN (short press)
• decrease one step
In surface or dive mode:
SEL
SEL
ESC
ESC
MIX
MIX
SCROLL UP (short press)
• increase one step (long press):• enter the function or confirm• light is available in:- top menu- chrono mode- dive mode
(long press)
• return to the TOP menu • switch depth AVG/stopwatch (GAGE mode)
(long press) Gas change (in NITROX mode)*
*
3
TOP MENU
DATE AND TIME DISPLAY 2ND TIMENO FLY TIMECOUNTDOWN
DESAT TIME COUNTDOWNSURF TIME
DESAT
(If the Watch is in desat Mode)
TOP(If the 2nd Time is ON)
2nd TIME
4
* If the computer is in OFF (lock) mode. The underwater diving funtcions are disabled.
STAGEINDICATOR
OXYGENDEEP STOP INDICATOR
ASCENT ALARMSPEED OFF
PPO2 VIOLATION
ALTITUDE MODEDAILY ALARM
BATTERY LOW
SAFETY FACTORINDICATOR
OXYGEN TOXICITY BAR
OFF MODE *
!
!
HIGH SPEED ASCENT!
5
MAIN SURFACE MENU
SEL ESC
DIVE-SET
SEL ESC
CHRONO
START / STOPRESET
SEL ESC
LOGBOOK
see page 10
MODE SELECT
SEL ESC
Scroll the Modeand confirm SEL
AIRMODE( )
NITROXMODE( )
APNEAMODE( )
GAUGEMODE( )LOCKMODE( )
• Deep stop ON /OFF• Safety Factor SF 0/1/2• Altitude ALT 0/1/2/3• PPO2 1.2 - 1.6
AIRMODE( )
• Deep stop ON /OFF• Safety Factor SF 0/1/2• Altitude ALT 0/1/2/3• % 02 21 - 50% GAS 1• PPO2 1.2 - 1.6 GAS 1• * % 02 21 - 99% GAS 2• * PPO2 GAS 2
NITROXMODE( )
• Surf Time Alarm SURF-T F1-F5 (surf time factor) /1’:00”-10’:00”/OFF• Depth Alarm DEPTH 1 - 50 m. (3-164 FT)/OFF• Step Depth Alarm STEP 2 - 25 m. (6-82 FT)/OFF• Dive Time Alarm DIVE-T 0’:10”-6’:00”/OFF
APNEAMODE( )
Scroll the SETand confirm SELScroll +/- and confirm SELESC TO RETURN
* Not avaible for GOA.
In off (lock) mode, the computer doesn’t monitor the body tissue. Don’t dive in off (lock) mode with residual desaturationAfter a dive in off (lock) mode wait at least 24hours before diving again.
!
6
SEL ESC
SETTING & INFO SYSTEM
see page 8/9
SEL ESC
PRE DIVE
see page 11
SEL ESC SEL ESC
TIME SET PLANNING
SLEEP ALARM ON/OFF
• SET H. 12/24• SET HOUR• SET MINUTE• SET D-M/M-D• SET DAY or MONTH• SET MONTH or DAY• SET YEAR
• SET HOUR• SET MINUTE
PO2 % 02
NO DECOTIME
DEPTH
INCREASE DEPTH
DECREASE DEPTH- SET 2nd TIME ON/OFF
Scroll +/- 30 Min.and confirm SEL
Scroll the SETand confirm SELScroll +/- and confirm SELESC TO RETURN
7
SYSTEM MENUPC LINK CHANGE UNITS
SEL TO CHANGE UNITS
ESC TO RETURN
ESC TO RETURN
HISTORY
HOURS IN USE
COUNTER
MAX DEPTH
HISTORY CONNECT THE INTERFACEAND DOWNLOAD LATESTSOFTWAREUPDATES
[ [
8
TISSUE ERASE
SEL ESC
SWITCH TO YESAND PUSH SEL.FOR 5 SEC.TO ERASETHE TISSUE
If you decide to erase the tissue nitrogen satu-ration using the T.ERASE function,the computer will not be able to calculate any successive dives in relation to nitrogen saturation! In any event, do not use this function if 48 hours have not passed since the last dive.
!
An ascent at too high speed increases the risk of decompression sickness! This function is strictly reserved for instructors who take full responsibility for the disactivation of the high speed ascent alarm (AL.SP).In any event, when activating this function the computer will show a barred speaker icon du-ring the entire dive.
!
HIGH SPEED ASCENT ALARM
SEL TO CHANGE ON/OFF ALARM SPEED
ESC TO RETURNFIRMWAREVERSION
NUMBEROF BATTERYCHANGES
SERIALNUMBER
INFO
9
LOGBOOK MENUAIR
MODE( )SAFETY FACTOR
DIVE TIME
MAX DEPTH
AVGDEPTH
TEMP.
(Page 1)
PPO2 MODE
(Page 2)
GAGEMODE( )
(Page 1)DIVE TIME
(Page 2)
MAX DEPTH AVG
DEPTHTEMP.
DEPTH STOPWATCH
(Page 2)
(Page 1)
NITROXMODE( )
(Page 3)
PPO2 O2%
* Not avaible for GOA.
DIVE TIME
SAFETY FACTOR
MAX DEPTH AVG
DEPTHTEMP.
APNEAMODE( )
(Page 1)
SCROLL DIP
TEMPSEL. DIP
NUMBERSEL. DIP
SURF TIMEPREV. DIP
DIVE TIMESEL. DIP
MAX DEPTH
SEL. DIP
(Page 2)
SESSION TIME
MAX SESS.DEPTH N° DIP TEMP.
SEL ESC
SURF TIME DIVE TIME
BEST SESS.
DIP TIME
10
PRE DIVE MENUAIR
MODEPPO2 MAX
NO DECO TIMEPPO2 MAX
DEPTH
FREE
DIVE TIME (MIN.)
MAX DEPTH
DIVE TIME(SEC.)
DEPTHDEPTH
GAGE
DIVE TIME (MIN.)
MAX DEPTH
DIVE TIME(SEC.)
NITROX
GASINDICATOR
PPO2 MAXDEPTH GAS 1
O2% GAS 1PPO2 MAX GAS 1
(Page 2)
GASINDICATOR
PPO2 MAXDEPTH GAS 2
O2% GAS 2PPO2 MAXGAS 2
Gas 1-2 Not avaible for GOA. 11
DIVE MENUAIR
DIVE TIME (MIN.)
MAX DEPTH
NO DECOTIME/ TOTALASCENT TIME
TEMP.DEPTH
(Page 2)
TIME
PPO2 MAX / PPO2 DEPTH MAX MODE
NITROX GAS SWITCH*
* Not avaible for GOA.
NITROXDIVE TIME
(MIN.)MAX DEPTH
NO DECOTIME/ TOTALASCENT TIME
TEMP.DEPTH
(Page 2)
MODETIME
02%
02%PPO2 MAX
PPO2 MAXDEPTH
GAS SWITCHINDICATOR
LONG PRESSFOR CHANGE
GAS1/2(Page 2)
Select the GASand confirm SEL
MIX*
12
GAGEDIVE TIME
(MIN.)MAX DEPTH
DEPTH
TEMP.AVG DEPTH
DIVE TIME(SEC.)
DEPTH STOPWATCH
START / STOPRESET
MODETIME
LONG PRESS FOR SWITCH DEPTH/AVG STOPWATCH
(Page 2)
AIRDESAT TIME
COUNTDOWNSURF TIME
DIVETIMEMAX
DEPTHNO FLYTIME
COUNTDOWN
NITROXDESAT TIME
COUNTDOWNSURF TIME
DIVETIME
MAX DEPTH NO FLY
TIMECOUNTDOWN
POST DIVEFREE
DIVE TIME (MIN.)
MAX DEPTH
TEMP.
DIVE TIME(SEC.)
DEPTHN° DIP
(Page 2)
TIME
SESSION TIME
13
BATTERYSURFACE
ESC TO END THE SESSION (SURFACE)
Scroll YES / NOand confirm SEL
FREEDIVE TIME
LAST DIPMAX DEPTH
LAST DIP
TEMP.SURFACE
TIME TOTALDIP
(Page 2)
LOW BATTERY (YOU SHOULD CHANGE THE BATTERY SOON)
YOU MUST CHANGE THE BATTERY
(DIVE FUNCTION IS DISABLED)
14
Note:
CARTESIOGOAGUIDE
DOWNLOAD THE COMPLETECRESSI INSTRUCTIONMANUALat: www.cressi.com/manuals
LONG LIFE
BATTERY
HIGH CONTRAST
DISPLAY
WIDE DIAMETER
DISPLAY
EASY ACCESS MULTI MODE
MENU
35
Via G. Adamoli, 501 - 16165 GENOVA - ITALY TEL. +39 010 830.79.1 - FAX +39 010 830.79.220
[email protected] - www.cressi.com
REV.
04_2
019