8/17/2019 BOP requirement post BOP
1/17
Lloyd’
s Register energy services
BOP and control systems –What’s new post Macondo?
Jeffry P. Sattler, P.E.Sr Vice President, EngineeringWEST Engineering ServicesSeptember 2012
8/17/2019 BOP requirement post BOP
2/17
Lloyd’
s Register energy services
Jeff Sattler• Sr. Vice President Engineering
• 33-year oil and gas career
• Began with West in 1993
• 15 years at Shell in various positions inthe Americas
• Degrees in Chemical and PetroleumRefining Engineering
8/17/2019 BOP requirement post BOP
3/17
Lloyd’
s Register energy services
Manufacturing, Testing, Maintenance,and Certification Requirements
• Current Status
• Issues
8/17/2019 BOP requirement post BOP
4/17
Lloyd’
s Register energy services
Current Status• Subsea failure rate comparison
SINTEF V
SINTEF II DW
Current JIP2000
0
1000
3000
4000
5000
6000
7000
7000
9000
10000
R a t e
, M T T F
, D a y s
106,526
8/17/2019 BOP requirement post BOP
5/17
Lloyd’
s Register energy services
Current Status• MTTF by Rig (Subsea)
13 (35%) of rigs had no associated failures
8/17/2019 BOP requirement post BOP
6/17
Lloyd’
s Register energy services
Current Status• Existing standards
• Class
• API• Specifications (design and manufacture)
• Recommended Practices (operations and maintenance)• Private
• Regulatory
• Generally considered minimums
8/17/2019 BOP requirement post BOP
7/17
Lloyd’
s Register energy services
Compliance to Standards
• Who verifies compliance?• What are competence requirements?
• How often?
8/17/2019 BOP requirement post BOP
8/17
Lloyd’
s Register energy services
WEST Verification Process
• Procedure developed over 26 years• Job specific
• Regulations, standards, best industry practices
• Decide what is mandatory• Includes controls (hydraulic and electronic)
• This standard is one among several in the oil
industry
8/17/2019 BOP requirement post BOP
9/17
Lloyd’
s Register energy services
Unintended Consequences?
• Consideration of reduced redundancy• Increased wellbore pressure testing
• Increased focus on repair work (non-
floaters)
8/17/2019 BOP requirement post BOP
10/17
Lloyd’
s Register energy services
Issues
• Focus on asking questions• Considerations
• And the answer is . . . . . ?
8/17/2019 BOP requirement post BOP
11/17
Lloyd’
s Register energy services
Manufacturing Standards
• Base (minimum) requirements• Compromises inevitable
• Consistent between manufacturers
• Gaps• Technology advances
8/17/2019 BOP requirement post BOP
12/17
Lloyd’
s Register energy services
Maintenance Systems
• Centralized or decentralized?• Control vs optimization
• _____ BEST ways to maintain?
• Is more better?
8/17/2019 BOP requirement post BOP
13/17
8/17/2019 BOP requirement post BOP
14/17
Lloyd’
s Register energy services
Repair
• Parts• RP 53 – “equal or better”
• Mix and match
• Buy out equipment• Upgrade (may not be available from OEM)
• Discontinued
8/17/2019 BOP requirement post BOP
15/17
8/17/2019 BOP requirement post BOP
16/17
Lloyd’
s Register energy services
Wrap-up
Compliance related answers will vary byproviders
• What is minimum standard?
• and are we happy with minimum?
8/17/2019 BOP requirement post BOP
17/17
For more information, please contact:
Jeffry P. Sattler, P.E.Sr Vice President, Engineering
WEST Engineering Services907 Bains StreetBrookshire, TX 77423
T +1 (281) 375 5515
E [email protected] w www.westengineer.com
The materials contained herein are summary in nature, subject to change and intended for general information only.Lloyd’s Register is the trading name of the Lloyd’s Register Group of entities. Services are provided by members of the Lloyd’s RegisterGroup. For further details, pleas e see our website: http://www.lr.org/about_us/our_Group/index.aspx.