MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
CHAPTER 1
INTRODUCTION
In Industry weighers & weighing mechanisms are to be very accurate. Without this accuracy,
extraction figures are meaningless. Weigher is the necessity either to weigh or to weigh the final
products to calculate extraction rate. Low cost automatic weighing machine using latest
technology of servo control and Programmable Logic Control (PLC) was designed and
developed considering the advantages of electronic weighing and linear motion guide ways
moving accuracies. The results of studies carried out for automatic weigher indicated that the
equipment could be used as weigher. Statistical analysis indicated that there was no significant
difference in mean value of measurements from set weights and measured weights at the 95%
probability level. Automatic weighing equipment can be successfully used for weighing and
dosing of products into bags, containers in automated production processes.
Automatic weighing machine consists of hopper, weigher with hooks arrangements for
empty bag & drop hole mechanism. Full open to half open or full close of the gate operates
through drop hole mechanism is used to fill the specified quantity of matter into the bag which
affects the accuracy of weighing. Continuous monitoring of set weight and matter feeding was
absent. Conventional filtering methods employed in dynamic weighing systems have limitation
in improving accuracy and throughput rate .Fluctuations in the bulk density of the raw materials
in volumetric or rotary charger dosing results in alterations in weight. Weighing machines
equipped with platform scales or beam balances with dials do not ensure the required accuracy of
weighing batch materials. Mechanical scales are not reliably precise and their applications in
automatic lines are complicated. Mechanically operated weighers are obsolete and maintenance
oriented. Electronic weighers are sophisticated and calibrate themselves by using built in
calibration procedures and saves the data themselves. Load cells are widely used in a variety of
industrial weighing applications such as wending machines and weighing systems. Load cells
interfaced with integrated electronics convert the weight force to an electric signal and deliver
the output signal to an automation system. Linear motion guide ways accompanied with
precision ball screw can greatly enhance moving accuracy. Hence, considering the advantages of
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 1
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
electronic weighing accuracy and linear motion guide ways moving accuracy, the present project
is undertaken to design and develop state of art technology i.e. low cost automatic weighing
machine using latest technology of servo control and Programmable Logic Control (PLC)
concepts.
The equipment works on the basic principle of batch weighing. Working flow diagram is as
shown in the Figure.1. Raw material to be weighed is automatically fed to the weighing hopper
through a quantity regulating servo slide. The movement of the slide is controlled by precision
linear motion guide way assembly which is driven by brushless servo motor. Feeding of the
material from the collection hopper to the weighing hopper is done in coarse and fine feed.
Automatic weighing cycle starts with wide opening of the servo slide followed by weight register
by the load cells. During rapid movement of the servo slide, more quantity of material is passed
to the weighing hopper. As the weight of the weighing hopper is nearing to the set weight, servo
slide moves slowly to provide fine feeding of the grain. As soon as the weight of the material in
the weigher hopper achieves the set value, the servo gate of the storage hopper closes and the
weigh hopper gate opens to discharge the set quantity of material on to a downstream process
line. Micro controller registers and updates the exact quantity of material discharged. When the
weigh hopper becomes empty, weigh hopper gate closes and the storage hopper servo slide
opens for the next weighing cycle.
The below figure shows how the process will go in the project . Firstly the the product which is
to be packed must be check that in what form it is present then the product is to placed in hopper
in bulk.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 2
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
Figure 1.1 Flow chart of process.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 3
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
CHAPTER 2
PROJECT DESCRIPTION
2.1 Shutter
The shutter is made up of iron in which we have use the iron sheet and ball bearings which help
in rotating the sheet according to our requirement . In this the size of the sheet is kept in such a
way that it covers the mouth of hopper from the bottom . The length and breadth of sheet is kept
(9x18 inches). The ball bearing which are used in it are such that when sheet is connected to the
motor used it drives the shutter forward & backward movement . Fig 2.1 sow the real shutter.
Figure 2.1 Closed Shutter
When the shutter moves in forward direction the path beside it left vacant which show that the
process is going on . Fig. 2.2 show the ball bearing & open view of shutter.
Figure 2.2 Opened Shutter
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 4
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
2.2 Hopper
A hopper is a large pyramidal shaped container used in industrial processes to hold particulate
matter that has been collected from expelled air. Hoppers are usually installed in groups to allow
for greater collection quantity. They are employed in industrial processes that utilize air pollution
control devices such as dust collectors, electrostatic precipitators, and bag houses/fabric filters.
Steel is the typical material of choice for hopper construction . Hopper walls are insulated in
order to protect the outside environment and personnel from the discarded contents. Oftentimes,
the bottom ¼ - 1/3 of the container is heated to eliminate the possibility of condensation inside
the hopper. The greatest difficulty associated with the removal of dust from the hopper is the
compaction of the ash. Moisture content, particle shape and size, and vibration are all factors that
contribute to the compaction. Typically vibrators are installed on the outer walls of a hopper to
shake and release the dust.
Figure 2.3 Hopper
2.3 LCD interfacing with Load Cell
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 5
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
The circuit shown below is of an 8051 based bi directional motor whose direction can be
controlled using 2 push button switches. The circuit is very similar to the previous one except
for the two push button switches . These pushbutton switches are interfaced to P0rt 3 of the
microcontroller. Resistors R2 and R3 are the pull down resistors for P3.0 and 3.1 respectively.
The code for the above project is so written that initially when power is switched ON, the motor
remains OFF. When push button switch S2 is pressed P1.0 goes high and P1.1 remains low. The
motor runs in the clockwise direction and this condition is maintained until S3 is pressed. When
push button switch S3 is pressed the logic of P1.0 and P1.1 toggles making the motor to run in
the opposite direction and this condition is maintained until the next press of S2.
Figure 2..4 Interfacing of LCD with DC Motor
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 6
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
CHAPTER 3
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 7
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
COMPONENTS DETAILS
3.1 LOAD CELL
The heart of any weighing system is the load cell. Whilst they are not exciting to watch, load
cells are highly accurate transducer which provides the user with information not generally
obtainable by other technology due to commercial factors. Load cells are designed to sense force
or weight under a wide range of adverse conditions; they are not only the most essential part of
an electronic weighing system, but also the most vulnerable. In order to get the most benefit from
the load cell, the user must have a thorough understanding of the technology, construction and
operation of this unique device. In addition, it is imperative that the user selects the correct load
cell for the application and provides the necessary care for the load cell during its lifetime.
Understanding these important issues and properly maintaining the load cells will ensure trouble
free weighing for a long period of time.
3.1.1 Origin of load cell
The sensing or spring element is the main structural component of the load cell. The element is
designed in such a way that it develops a strain, directly proportional to the load applied. Sensing
elements are normally made of high strength alloy steels (nickel plated for environmental
protection), precipitation - hardened stainless steels, heat treated aluminium alloys, or beryllium
copper alloys. By bonding strain gages to a precisely machined element, the force applied can be
identified in terms of resistance change. The strain gages, usually four or a multiple of four, are
connected into a Wheatstone bridge configuration in order to convert the very small change in
resistance into a usable electrical signal. Passive components such as resistors and temperature
depending wires are used to compensate and calibrate the bridge output signal.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 8
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
Figure 3.1: Strain gages
3.1.2 Accuracy of load cell
Load cells are ranked, according to their overall performance capabilities into differing accuracy classes. Some of these accuracy classes are related to standards which are used in legal for trade weighing instruments, while other accuracy classes are defined by the individual load cell manufacturer. Depending on the standard and the performance of a particular load cell type, an alphanumeric “accuracy grade” is given to the product. The alpha designate refers to the specific accuracy class, while the numeric part refers to the number of divisions. Revere Transducers manufactures products meeting NTEP, OIML and in-house specifications. These product are designated: Az Products meet the NTEP requirements for class III applications. Bz Products meet the NTEP requirements for class IIIL applications. Cz Products meet the OIML requirements for class III and IIII applications. CC/D3 These are arbitrary in-house classifications for products used in non-trade applications. Note “z” represents the number of divisions
(x1000), i.e. A3, B10, C6, etc.Most weighing systems use load cells where their working or measuring range is well below their rated capacity. In these situations, the values for the load cell utilisation and minimum verification interval (vmin) are important.The minimum verification interval is defined as the smallest value of a quantity (mass) which may be applied to a load cell without exceeding the maximum permissible error. It is specified as Emax/γ, where Emax represents the load cell’s rated capacity and γ represents a value which is specified by the load cell supplier.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 9
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
3.2: Digital Load Cell
Digital load cells are still niche products. They are available as calibrated C3 and C6 cells as well
as uncalibrated types. Typical applications are set-ups with long wires (where the digital signal
transmission is better than analog), when several load cells are processed by one single
controller, e.g. truck scales or in electro-magnetical noisy environments. The advantages can
therefore be concluded as: ƒ Long cable lengths possible without loss in signal strength.
Combination of several load cells processed by a single processor ƒ Reduced sensitivity to EMI
ƒ Good replaceability as intrinsically calibrated cells. In order to get a more detailed picture of
what a digital load cell is or how its concept is like we have a look at its set-up nowadays. As
mentioned in the introduction it basically consists of the load cell itself combined with the
electronics which is a converter and a microcontroller.
Figure3.2: Load cell with analog to digital converter
The signal generated by the strain gages on the load cell are given to the electronics . Here an
A/D converter digitizes the analog signal and feeds the micro- controller or DSP with the A/D
raw count. The controller processes then the raw values, corrects them in terms of linearization,
filtering, hysteresis, etc. and finally puts out the digital signal.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 10
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
Digital load cells are still only used in special applications like truck scales, silo scales, container
scales, etc. In common standard scales like i.e. bench scales or legal for trade scales they are not
used very often.
But exactly in this area there is a lot of benefit in using DLCs, some advantages cannot be
realized by using the analog load cell. The idea of a new possible structure is illustrated in the
following picture:
Figure 3.3: Separation of analog (weighing) part and the digital part
The analog part includes the sensor (load cell) and the electronic. The knowledge about weighing
lies in this part, i.e. construction of a good load cell or to make calibration, temperature
compensation, etc. The output is fully digital signal which delivers the weighing information
already fully calibrated.
The pure digital part on the other hand receives the digital data stream and just handles tasks like
displaying of the weight, recognition of buttons or interface other devices (e.g. network scales).
Also, language or country localization can be done in the software here. To make the digital part
there is not much knowledge about weighing itself needed.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 11
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
3.3 Circuit diagram of Digital Load cell
Figure 3.4: Circuit diagram of load cell
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 12
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
3.4 Components of load cell
1. Crytal Oscillator : It is an electronic oscillator circuit that uses the mechanical resonance of
a vibrating crystal of piezoelectric material to create an electrical signal with a very
precise frequency. This frequency is commonly used to keep track of time (as in quartz
wristwatches), to provide a stable clock signal for digital integrated circuits, and to stabilize
frequencies for radio transmitters and receivers. The most common type of piezoelectric
resonator used is the quartz crystal, but other piezoelectric materials including polycrystaline
ceramics are used in similar circuits.
Quartz crystals are manufactured for frequencies from a few tens of kilohertz to tens of
megahertz. More than two billion crystals are manufactured annually. Most are used for
consumer devices such as wristwatches, clocks, radios, computers, and cellphones. Quartz
crystals are also found inside test and measurement equipment, such as
counters, and oscilloscopes.
Figure 3.5:Crystal Oscillator
2. AT89S52: All four ports in the AT89C51 and AT89C52 are bidirectional . Each consists of a latch (Special Function Registers P0 through P3), an output driver, and an input buffer . The
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 13
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
output drivers of Ports 0 and 2, and the input buffers of Port 0, are used in accesses to external memory. In this application, Port 0 outputs the low byte of the external memory address, time-multiplexed with the byte being written or read. Port 2 outputs the high byte of the external memory address when the address is 16 bits wide. Otherwise the Port 2 pins continue to emit the P2 SFR content. All the Port 3 pins, and two Port 1 pins (in the AT89C52)are multifunctional . The alternate functions can only be activated if the corresponding bit latch in the port SFR contains a 1. Otherwise the port pin is stuck at 0. It has less complex feature than other microprocessor.
Figure 3.6:Microcontroller
3. DC Motor : A DC motor is a mechanically commutated electric motor powered from direct
current (DC). The stator is stationary in space by definition and therefore so is its current.
The current in the rotor is switched by the commutator to also be stationary in space . This is
how the relative angle between the stator and rotor magnetic flux is maintained near 90
degrees, which generates the maximum torque.
DC motors have a rotating armature winding but non-rotating armature magnetic field and a
static field winding or permanent magnet. Different connections of the field and armature
winding provide different inherent speed/torque regulation characteristics. The speed of a DC
motor can be controlled by changing the voltage applied to the armature or by changing the
field current. The introduction of variable resistance in the armature circuit or field circuit
allowed speed control. Modern DC motors are often controlled by power electronics systems
called DC drives.
The introduction of DC motors to run machinery eliminated the need for local steam or
internal combustion engines, and line shaft drive systems. DC motors can operate directly
from rechargeable batteries, providing the motive power for the first electric vehicles. Today
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 14
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
DC motors are still found in applications as small as toys and disk drives, or in large sizes to
operate steel rolling mills and paper machines.
Figure 3.7:DC Motor
4. Weighing scale :It is a measuring instrument for determining the weight or mass of an
object. A spring scale measures weight by the distance a spring deflects under its load.
A balance compares the torque on the arm due to the sample weight to the torque on the arm
due to a standard reference weight using a horizontal lever. Balances are different from
scales, in that a balance measures mass (or more specifically gravitational mass), where as a
scale measures weight (or more specifically, either the tension or compression force of
constraint provided by the scale). Weighing scales are used in many industrial and
commercial applications, and products from feathers to loaded tractor-trailers are sold by
weight. Specialized medical scales and bathroom scales are used to measure the body
weight of human beings.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 15
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
Figure 3.8:System Block Diagram
Figure 3.9: Digital Weighing Scale
5. Seven Segment Display: A seven-segment display (SSD), or seven-segment indicator, is
a form of electronic display device for displaying decimal numerals that is an alternative
to the more complex dot-matrix displays. Seven-segment displays are widely used in
digital clocks, electronic meters, and other electronic devices for displaying numerical
information. Seven-segment displays may use a liquid crystal display (LCD), arrays of
light-emitting diodes (LEDs), or other light-generating or controlling techniques such as
cold cathode gas discharge, vacuum fluorescent, incandescent filaments, and others. For
gasoline price totems and other large signs, vane displays made up of electromagnetically
flipped light-reflecting segments (or "vanes") are still commonly used. An alternative to
the 7-segment display in the 1950s through the 1970s was the cold-cathode, neon-lamp-
like nixie tube. Starting in 1970, RCA sold a display device known as the Numitron that
used incandescent filaments arranged into a seven-segment display. In a simple LED
package, typically all of the cathodes (negative terminals) or all of the anodes (positive
terminals) of the segment LEDs are connected and brought out to a common pin; this is
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 16
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
referred to as a "common cathode" or "common anode" device. Hence a 7 segment plus
decimal point package will only require nine pins (though commercial products typically
contain more pins, and/or spaces where pins would go, in order to match industry
standard pinouts). Common cathode implementations require logic low (0) to turn on a
segment, common anode implementations require logic high (1) to turn on a segment.
Integrated displays also exist, with single or multiple digits. Some of these integrated
displays incorporate their own internal decoder, though most do not: each individual LED
is brought out to a connecting pin as described. Multiple-digit LED displays as used in
pocket calculators and similar devices used multiplexed displays to reduce the number of
IC pins required to control the display. For example, all the anodes of the A segments of
each digit position would be connected together and to a driver pin, while the cathodes of
all segments for each digit would be connected. To operate any particular segment of any
digit, the controlling integrated circuit would turn on the cathode driver for the selected
digit, and the anode drivers for the desired segments; then after a short blanking interval
the next digit would be selected and new segments lit, in a sequential fashion. In this
manner an eight digit display with seven segments and a decimal point would require
only 8 cathode drivers and 8 anode drivers, instead of sixty-four drivers and IC pins.
Figure 3.10 Seven Segment
6. LCD Display: A liquid crystal display (LCD) is a flat panel display, electronic visual
display, or video display that uses the light modulating properties of liquid crystals. Liquid
crystals do not emit light directly. LCDs are available to display arbitrary images (as in a
general-purpose computer display) or fixed images which can be displayed or hidden, such as
preset words, digits, and 7-segment displays as in a digital clock. They use the same basic
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 17
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
technology, except that arbitrary images are made up of a large number of small pixels, while
other displays have larger elements. LCDs are used in a wide range of applications including
computer monitors, televisions, instrument panels, aircraft cockpit displays, and signage.
They are common in consumer devices such as video players, gaming devices, clocks,
watches, calculators, and telephones, and have replaced cathode ray tube (CRT) displays in
most applications. They are available in a wider range of screen sizes than CRT and plasma
displays, and since they do not use phosphors, they do not suffer image burn-in. LCDs are,
however, susceptible to image persistence. The LCD screen is more energy efficient and can
be disposed of more safely than a CRT. Its low electrical power consumption enables it to be
used in battery-powered electronic equipment. It is an electronically modulated optical
device made up of any number of segments filled with liquid crystals and arrayed in front of
a light source (backlight) or reflector to produce images in color or monochrome. Liquid
crystals were first discovered in 1888.[2] By 2008, worldwide sales of televisions with LCD
screens exceeded annual sales of CRT units; the CRT became obsolete for most purposes.
Displays for a small number of individual digits and/or fixed symbols (as in digital watches
and pocket calculators) can be implemented with independent electrodes for each segment. In
contrast full alphanumeric and/or variable graphics displays are usually implemented with
pixels arranged as a matrix consisting of electrically connected rows on one side of the LC
layer and columns on the other side, which makes it possible to address each pixel at the
intersections.
Figure 3.11 LCD Display
CHAPTER 4
RESULT
4.1 RESULT
Conceptual design was carried out and fabrication drawings were prepared. Assembly of
fabricated items and bought out items was carried out and trial run of the equipment was
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 18
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
conducted. Evaluation of the system was done by taking wheat for weighing experiments which
had the following characteristics on dry basis: 9% moisture, 76 kg per hectoliter weight, 32
grams per 1000 kernel weight and hardness value of 10kg per grain. Above parameters indicated
that wheat used was medium hard type. Table1. shows comparison of set weights and measured
weights of wheat samples from 1000 grams to 5000 grams with an incremental value of 500
grams. P-values for 1500, 3500, 5000 grams were 0.889, 0.068 and 0.48 respectively. Fstatistical
values for 1500, 3500, 5000 grams were 0.019, 3.766 and 0.507 respectively. Fcritical values for
1500, 3500, 5000 grams were 4.414, 4.414 and 4.098 respectively. Fstatistical < Fcritical and P-
values > 0.05, there is no statistical difference in mean value of measurements from set weights
and measured weights. For 1000, 2000, 2500, 3000, 4000 and 4500 grams, P-values > 0.05 and
Fstatistical > Fcritical indicated that there is a significant effect due to weight measurements at
the 95% probability level.
Differences could be minimized by proper tuning of storage hopper gate open speed, feed speed
and close rapid speed parameters . Average percentage error was observed from 0.1% to 0.6%.
Minimum average percentage error (< 0.2%) was observed for 3500, 4000, 4500 and 5000grams
weight measurement. Maximum average percentage error (>0.2% and <0.6%) was observed for
1000, 1500, 2000, 2500 & 3000 grams weight measurement. This could be further minimized by
altering the position of reader limit switch and by tuning of storage hopper gate open speed, feed
speed and close rapid speed parameters.
Weight measurements on the dispensed material under repeatability conditions produced results
within ± 0.22% of displayed set weight for 3000,3500,4000,4500 and 5000 grams. Repeatability
of greater than ± 0.22% was observed for 1000, 1500, 2000 and 2500 grams displayed set
weights which were due to material weighing speed. Improve in repeatability limit could be
possible by slowing down weigh up cycle.
4.2 PROBLEM FACED
Due to heavy and large machine we are getting problem in doing shuttering.
Difficult to understand the load cell circuit
Errors in weighing.
4.3 PRECAUTIONS
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 19
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
The load cell has to handle with care.
Its structure is to learn properly with conc.
Proper supply should be maintained and sensor should handled properly.
CHAPTER 5
FUTURE SCOPE AND CONCLUSION
5.1 CONCLUSION
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 20
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
The results of studies carried out for the Design & Development of low cost, servo based PLC
operated grain / grain products automatic weigher indicated that the equipment could be used as
weigher in Flour mills. Statistical analysis indicated that there was no significant difference in
mean value of measurements from set weights (1500, 3500, 5000 grams) and measured weights
at the 95% probability level. Minimum average percentage error (< 0.2%) was observed for
3500, 4000, 4500 and 5000grams weight measurements. Weight measurements on the dispensed
material under repeatability conditions produced results within ± 0.22% of displayed set weight
for 3000,3500,4000,4500 and 5000 grams revealed that weighing of product by auto grain
weigher is very precise. Automatic weighing equipment can be successfully used for weighing
and dosing of any granular products into bags, containers in automated production processes.
5.2 FUTURE SCOPE
In India from very last year we are watching that many bags are being packed and weighed
manually but now there is a great shortage of man power in every field so to overcome this
problem we have design a machine which automatically weigh and pack the material that has to
weighed or packed so that there is less use of man power & it also save the time and money.
5.3 Automatic Machines Vs Prices in India
The following figure show how the prices in India has affect the use of automatic machines. The
machines are used in each and every part of life.
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 21
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
Figure 5.1 Rate of uses of Automatic Machines in India
REFRENCES
1. http://www.radwag.com/pliki/artykuly/
good_weighing_practice_in_pharmaceutical_industry.pdf
2. http://mofpi.nic.in/images/cftri_rd.pdf
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 22
MINOR PROJECT REPORT AUTOMATIC WEIGHING AND PACKAGING MACHINE
3. http://en.wikipedia.org/wiki/Load_cell
4. http://www.rdjacobs.com/pdf/Loadcell_spec.pdf
DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERINGPage 23
Top Related