Page: Architectural Details
Architectural Details
Metal Siding with Girts, Wall Sections Page Standard Sidewall Section (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Standard Sidewall Section (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
Standard Sidewall Section (Flush Girt System) with Eave Extension. . . . . . . . . . . . . . . . Sec-03
Standard Sidewall Section (Bypass Girt System) with Eave Extension. . . . . . . . . . . . . . Sec-04
Bearing Endwall Section (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-05
Rigid Frame Endwall Section (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-06
Bearing Endwall Section (Flush Girt System) with Rake Extension . . . . . . . . . . . . . . . . . Sec-07
Rigid Frame Endwall Section (Flush Girt System) with Rake Extension . . . . . . . . . . . . . Sec-08
Metal Siding with Girts and Studs, Wall Sections Page Standard Sidewall Section (Flush Girt System) with Stud Walls . . . . . . . . . . . . . . . . . . . Sec-01
Standard Sidewall Section (Bypass Girt System) with Stud Walls . . . . . . . . . . . . . . . . . . Sec-02
Standard Sidewall Section (Flush Girt System) with Eave Extension & Stud Walls . . . . . Sec-03
Standard Sidewall Section (Bypass Girt System) with Eave Extension & Stud Walls . . . Sec-04
Bearing Endwall Section (Flush Girt System) with Stud Walls . . . . . . . . . . . . . . . . . . . . . Sec-05
Rigid Frame Endwall Section (Flush Girt System) with Stud Walls . . . . . . . . . . . . . . . . . Sec-06
Bearing Endwall Section (Flush Girt System) with Rake Extension & Stud Walls . . . . . . Sec-07
Rigid Frame Endwall Section (Flush Girt System) with Rake Extension & Stud Walls . . Sec-08
Brick, Wall Sections
Sidewall Sections (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Sidewall Sections (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
Sidewall Sections (Flush Girt System) with Eave Extension . . . . . . . . . . . . . . . . . . . . . . Sec-03
Sidewall Sections (Bypass Girt System) with Eave Extension . . . . . . . . . . . . . . . . . . . . . Sec-04
Rigid Frame Endwall Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-05
Rigid Frame Endwall Section with Rake Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-06
Partial Brick, Wall Sections
Sidewall Section (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Endwall Section (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
E.I.F.S., Wall Sections
Sidewall Section (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Sidewall Section (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
Sidewall Section (Flush Girt System) with Eave Extension . . . . . . . . . . . . . . . . . . . . . . . Sec-03
Sidewall Section (Bypass Girt System) with Eave Extension . . . . . . . . . . . . . . . . . . . . . . Sec-04
Rigid Frame Endwall Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-05
Rigid Frame Endwall Section with Rake Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-06
Metal Siding with Hat Sections and Studs, Wall Sections
Sidewall Section with Wall Panels (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Sidewall Section with Wall Panels (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
Sidewall Section with Wall Panels and Eave Extensions . . . . . . . . . . . . . . . . . . . . . . . . . Sec-03
Rigid Frame Endwall Section with Wall Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-04
Rigid Frame Endwall Section with Rake Extension & Wall Panels . . . . . . . . . . . . . . . . . . Sec-05
Concrete Tilt-Wall, Wall Sections
Sidewall Section (Flush Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-01
Sidewall Section (Bypass Girt System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-02
Rigid Frame Endwall Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec-03
PURLIN
EAVE STRUT
BLANKET INSULATION
"X" BRACING
FLANGE BRACE
RAFTER
5 1/2"
"X" BRACING (IF REQ'D)
METAL ROOF PANEL
COLUMN
4"
DOWNSPOUT
GUTTER STRAP
DOWNSPOUT
GUTTER
WALL PANEL
BRICK (NOT BY T.B.S.METAL BUILDING DIVISION)
DRIP TRIM
OUT OF SLAB & BUILDING STEEL
ANCHOR RODS
STUD FRAMING(NOT BY T.B.S. METALBUILDING DIVISION)
WALL SHEATHING(NOT BY T.B.S. METALBUILDING DIVISION)
BLANKET INSULATION
EA
VE
HT
.
BACKSPLASH TRIM (OPTIONAL)
1 1
/2"
BR
ICK
HE
IGH
T A
BO
VE
AL
L F
RA
ME
D O
PE
NIN
GS
DOWNSPOUT STRAP(MK~T-116)
(2) 1/4"x1 1/4" CONKWIK SCREW
4"
1 1/4"
MOISTURE BARRIER(NOT BY T.B.S. METALBUILDING DIVISION)
5 1/2"x1 1/2" BRICK NOTCH
CONTINUOS GIRTDESIGNED TOSUPPORT WALL(CANNOT BE CUT TORECIEVE ANY FRAMEDOPENINGS)
DO
OR
S, W
IND
OW
S, O
VE
RH
EA
D D
OO
RS
, E
TC
.M
US
T B
E B
EL
OW
TO
P O
F B
RIC
K
SIDEWALL SECTION AT PARTIAL BRICK WALL
(BYPASS GIRT SYSTEM REQUIRED)
GIRT
I:\Wall Sections\Partial Brick\Sec-01.dwg
5 1/2"
WALL PANEL
BRICK (NOT BY T.B.S.METAL BUILDING DIVISION)
OUT OF SLAB & BUILDING STEEL
ANCHOR RODS
STUD FRAMING(NOT BY T.B.S. METALBUILDING DIVISION)
WALL SHEATHING(NOT BY T.B.S. METALBUILDING DIVISION)
BLANKET INSULATION
MOISTURE BARRIER(NOT BY T.B.S. METALBUILDING DIVISION)
5 1/2"x1 1/2" BRICK NOTCH
ENDWALL COLUMN
PURLIN
METAL ROOF PANEL
RAKE TRIM
SHEETING ANGLE
4"
1 1
/2"
DRIP TRIM
RAFTER
FLANGE BRACE
DO
OR
S,
WIN
DO
WS
, O
VE
RH
EA
D D
OO
RS
, E
TC
.M
US
T B
E B
EL
OW
TO
P O
F B
RIC
K
CONTINUOS GIRTDESIGNED TOSUPPORT WALL(CANNOT BE CUT TORECIEVE ANY FRAMEDOPENINGS)
BR
ICK
HE
IGH
T A
BO
VE
AL
L F
RA
ME
D O
PE
NIN
GS
ENDWALL SECTION AT PARTIAL BRICK WALL
(BYPASS GIRT SYSTEM REQUIRED)
ENDWALL COLUMNCLIP
GIRT
I:\Wall Sections\Partial Brick\Sec-02.dwg