We take care of it.

EORSys

An expert solution is within your reach.•Systemsolutionforcompensated,

isolatedandsolidlygroundedgrids

•Precisecontrolofarcsuppressioncoils

•Reliablelocatingofearthfaults

•Detectionofrestrikingfaults

•Detectionofshortcircuits

•Faultdatarecording

•Extensivecommunicationcapabilities

fordevicesremoteconnection

•Servicing,commissioningandfailure

analysis

Page 2: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

EORSys

Transient method using the qu2 principle, suitable for detection•offaultsupto3kOhm•ofparallelcablesandinringgrids•offaultsinspurcables

Detecting restriking faults using the qui method•directionaldisplayofrestrikingfaults•faultindication

Watt-metric Method cos(ϕ)•forWattresidualcurrent•forWattresidualpowerincrease withadditionalresistance

Harmonic method for 250 Hz

Harmonic method for locating with ripple control signals

Pulse location method •classicalwithcapacitors•fastpulselocation

Short-circuit detection using the definite time overcurrent principle (EOR-3D only)•directional•non-directional

TheEORSysproductfamilyoffersacompletesolutionforgridswithresonantearthed,isolatedandsolidlygroundedneutral .

Solutions for compensated grids

Usingthecontrollerforvariablearcsuppressioncoils(REG-DPandREG-DPA)youcancomfortablyregulateincompensatedgridstothecorrecttuningpoint.Ifregulationisabitmorecomplicatedormoredifficultduetonon-linearloads,theoptionalyavailableREG-DPandREG-DPAcurrentinjec-tionprovidesaremedy.Thecurrentinjectionenablesprecisecompensa-tion/tuningofthearcsuppressioncoilsunderthemostdifficultconditions.

Ifanearthfaultoccursinthegrid,multipleA.Eberledevicesaresi-multaneouslyavailabletoaccuratelylocateit.Thefollowinglocalisationmethodsareincludedfordetectionincompensatedgrids:

EORSysproductrangedeployment

Page 3: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

Quickly locating earth faults. Safe control of Petersen coils

Earthfaulttests-restrikingfaults

EORSys

Solution for isolated grids

Indistributiongridswithaninsolatedneutralthefollowingdetectionproce-duresareavailable.

Transient method using the qu2 principle, suitable for location•inparallelcablesandinringgrids•offaultsinradialfeeders

Detecting restriking faults using the qui method•directionaldisplayofrestrikingfaults•faultindicationdisplay

Harmonics method sin(ϕ)

Harmonic method for 250 Hz

Harmonic method for locating with ripple control signals

Short-circuit detection using the definite time overcurrent principle (EOR-3D only)•directional•non-directional

Engineering serviceControl

Location

Report

Data analysis

Solution for rigid/low impedance grounded systems

Insolidlyorlow-impedancegroundedgrids,nosignificantincreaseinthezerosequencevoltageoccurswithasingle-phasefault.Inaddition,thefaultcurrent,whencomparedtocompensatedandisolatedgridsismuchhigherinthatcase.Onlyoneformoffaultdetectionremainsthenavailable.

Short-circuit detection using the definite time overcurrent principle (EOR-3D only)•directional•non-directional

Page 4: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

EORSys

A Controller for arc suppression coils

REG-DPandREG-DPA

TheREG-DPdevices(19"technology)andREG-DPA(industrialenclosures)areprimarilyusedfortheauto-tuningofadjustablearcsuppressioncoils.Theyareusedincoilsinmediumvoltagegridsandhigh-voltagegridsupto110kV.

Forgoodcontrolperformance,thephaseangleinformationistakenintoaccountinadditiontothevalueofthezerosequencevoltage.Consequently,evensmallchangesinthevaluescanbecompensated.

Ofcourse,eachcontrollercanperformothertasksthatsupportthecontrolorevenapossibleearthfaultlocalisation.

Thecontrollersalsoprovidethefollow-ingfeatures:

•Controlforfixedcoils,parallelfor plunge-corecoils•Parallelcontrolofplunge-corecoils throughcommunicationbetween controldevices•Parallelcontrolofplunge-core coilswithoutcommunication betweencontroldevices•ControllingtheresistorfortheWatt residualcurrentincrease;includingthe thermalimageoftheresistanceand thusoverheatingprotection•Connectionandcontrolofthe currentinjection•Compensationduringanearthfault (onlyincombinationwiththeEOR-D)•Controlofthepulsingcurrentfor classicalpulselocatingmethod

Thecontrolofthepulsingcurrentcanbefreelyprogrammedindividuallytoyourrequirements.

Henceaprogramensuresthecorrectdegreeofovercompensation,thecon-trolofthepulsedevicesandthemoni-toringofthepulsecycles.

Forcommunicationwiththecontrolcentretherearesufficientrelayoutputsorallcurrentcommunicationprotocolsavailable.

Current injection

ThecontrolofarcsuppressioncoilscanbedifficultundercertainconditionsWhy?Becauseoftheincreasinglevelofcablingofmoderngrids.Thisincreasesthenaturalsymmetryoftheconductor.

Page 5: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

Petersencoilwithintegratedcurrentinjection

EORSys

Ontheotherhand,itreducesthemag-nitude(zerosequencevoltage),whichisusedforthecontrolpurpose.

Thecurrentinjectioniscapable,withouttheadjustmentoftheplunge-corecoil,toidentifythetuningpointbyapplyingadefinedsignal.Thusitisparticularlysuitableforthesedifficultsituations:

•Verysmallzerosequencevoltage•Unstablezerosequencevoltagedue toloadcrosstalk

•Changingthenaturalsymmetryper phaseatconstanttotalcapacity

Theso-calledcurrentinjectionwasdevelopedpreciselyforsuchcases.

REG-DP/DPA: The expert solution.

Unstable history of the zero sequence voltage over 14 days with a constant grid capacity

Page 6: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

EORSysProductrange:ThePetersencoilcontrolandfaultlocationsystem

EORSys

EOR-D earth fault locating relay

Reliableearthfaultlocationisnecessaryincompensatedandisolatedgridsduetothelowfaultcurrents.

TheEOR-Dprovidestheabilitytomonitor4outputfieldsforearthfaultsperunit.Multipledevicescanbecon-nectedtoasinglesystem.Theadvan-tageisthatoneneedsonlyonecon-figurationfortheearthfaultrecordingpersubstationorperstation.Inaddi-tion,thissimplifiestheremotecontrolcenterconnection.Onlyoneprotocolconverterisrequiredforeachsystem.

Sinceeachgridisdifferent,thereisnoonelocationmethodforallsituations.TheEOR-Dprovidesachoiceofsev-eralmethods:

•Directionaltransientdetectionusing thequ2method•Directionaldetectionofrestriking faultsusingthequimethod•Directionaldetectionusingthe harmonicmethod•Localisationusingripple-control signalsandtheharmonicmethod•watt-metricmethodcos(ϕ)•Pulselocationmethod•Harmonicsmethodsin(ϕ)usedfor isolatedgrids

Combined earth fault and short circuit indicator - EOR-3D

Thedevicefordirectionaldetectionofearthfaultsandshort-circuitsforasingleoutputfieldistheEOR-3D.ItcanhandlealllocalisationmethodsusingthesamealgorithmsastheEOR-D.Inaddition,ithasdirectionalornon-directionalshort-circuitdetection.

Duetoitscompactdesign,itisalsoeasytoinstallinsmallstations.

Page 7: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

EORSys

Special features of the EOR-3D

•4GBofinternalmemoryforfault recordinginsecondranges -oscilloscoperecording -displayofthedigitaltraces•CommunicationusingTCP/IP, USB2.0,RS232,RS485•colourOLEDdisplay•forlocaloperationviakeyboard andgraphicdisplay•integratedcontrolprotocolsfor –IEC60870-5-101/103/104 –MODBUSRTUandTCP –DNP3.0RS485andTCP•Useincombinationwithconven- tionaltransducersandsensors

One system, many solutions

EOR-3DDINrailversion

EOR-1ESwithloadcurrentmonitoring

EOR-3Dindustrialhousing

NEW! EOR-1 - simple earth fault and short circuit indicator with matching sen-sors in set for cables and overhead lines

TheEOR-1rangeofdevicesissuitableforwideuseinallformsofgrids.Theyarecharacterizedbytheirsimplicityofoperationandinstallation:

•Earthfaultandshortcircuitindica- torusingcurrentdetection•Signallingthroughrelaycontacts•Externalsignallingunitsavailable•Nooperatingsoftwarenecessary•Powersupplyfrominternal battery(externalpowersupply availableasoption)

•unexpensiveandrobustcurrent sensorsforallcommonconductor diameters•Currentsensorsfordirectwire installation(withfibre-opticoutput)•Remotesignallingthroughrelay contacts•EOR-1ESmodelwithintegrated MODBUSmodulewithpower savingmode-noexternalsupply needed!•Overheadlineindicatorwithremote controlanddatareadout

Page 8: An expert solution is within your reach. · 2019-05-10 · An expert solution is within your reach. • System solution for compensated, isolated and solidly grounded grids • Precise

A. Eberle GmbH & Co. KGFrankenstraße160D-90461NurembergFon +49(0)911628108-0Fax +49(0)911628108-99Email [email protected] www.a-eberle.deEO

RSys

_E_0

4_20

14_n

ue

Yoursalespartner

Protocol REG-DPREG-DPA

EOR-D EOR-3D EOR-1 ES

MODBUS RTU x x x

MODBUS TCP x x

DNP 3.0 x x x

DNP 3.0 TCP x x x

IEC 60870-5-101 x x x

IEC 60870-5-103 x x x

IEC 60870-5-104 x x x

IEC 61850 (Ed. 1/2 x x

REG-DP/REG-DPA–Thecontrollerforplunge-corecoils.

EOR-D–Earthfaultdetectionforsubstationsandstationswithmultiplefeeders.

EOR-3D–Earthfaultandshortcircuitindicator forsubstations,compactstationsuptolocalgridstationswithspecialrequirements.

EOR-1 ES–Earthfaultandshortcircuitindicatorforcompactandlocalgridstations;optimizedandreducedtoessentialfunctions.

AlldevicesintheEORSysrangecanbeconnectedeasilyusingcontroltech-nology.Thereareenoughrelayoutputsavailableforconventionaltelecontrol.Alternatively,thedevicessupportthefollowingcommunicationprotocols:

Remote signalling/communication