Glass fragmentations
are the main cause of
serious injures in
blast scenarios
Al-Sorag offers
five levels of
proven
solutions
Level 1- Safety Film
Safety film is a very efficient answer to prevent scattering of shattered glass.
Safety film fits to any type of flat glass .
System withstands -Up to 4 P.S.I and 28 P.S.I*msec
Without safety film
Sharp glass shards fly across the room
With safety film
The window is retained in its frame
Level 2 - No-Bar TM system
No-Bar TM system – An original anchoring system, developed,
produced, installed and marketed by Al-Sorag Ltd.
No-Bar TM system– Includes most varied installation options.
No-Bar TM system– More then 5,000 sqm installed during 2004.
System withstands - Up to 6 P.S.I and 100 P.S.I*m/sec
Blast test in Israel – November 2004
Standoff - 80 meter
830 k”g T.N.T
The window stays fully attached
Level 2 - NO-BAR TM system
Completed Project
“Orange” – cellular phone companyOver 1000 sq/m project
Level 3 - Cable system
Cable system- A retrofit solution that combines safety film with
a “smart” blast wave energy absorbing mechanism.
Cable system- Including most varied installation options.
Cable system- Executed over 100 projects during 2002-2004
around the world by Al-Sorag Ltd.
System withstands – Up to 15 P.S.I and 115 P.S.I*msec
Blast test- Israel 2000
�� 3000 lbs ANFO3000 lbs ANFO
�� 85 meters standoff85 meters standoff
�� 15 PSI15 PSI
�� 89 PSI*89 PSI*msecmsec
�� GSA level DGSA level D
Level 3 - Cable system
Completed Projects
Bank Leumi in Jerusalem
Level 3 - Cable system
Level 4 - Clear Bar TM
System withstands - Up to 29 P.S.I and 203 P.S.I *msec
Clear Bar TM - Advanced retrofit solution of ultra-
clear “bars” anchored to the building
construction.
Clear Bar TM - High performance blast resistance
Superior break- in barrier, with a
transparency advantage.
Clear Bar TM - An original clear system – developed,
tested, produced and marketed by
Al-Sorag Ltd.
Level 4 - Clear Bar TM
System withstands - Up to 29 P.S.I and 203 P.S.I*msec
Official Test performed November 11th, 2004 in Israel
Before
“No-Bar” 700 micron + Clear Bar
During
830 k”g T.N.T,
40 m’ standoff
Level 4 - Clear Bar TM
Official Test performed November 11th, 2004 in Israel
Pressure: 23 P.S.I impulse: 203 P.S.I*msec
After
Al-Sorag Solutions and Corresponding Security Levels
Test ResultsImpulsePressureBack SystemCoating Attachment CoatingAssembly
Type(GSA ranking)[psi-msec][psi]TypeTypeType
3b30.34.4--R012306T
4mil (100
mic)
"Day-
Light"
3a586-No-BarTMR32303T
12mil (350
mic)
No-BarTM
350/2s
3a7015-No-BarTMR32303T
24mil (700
mic)
No-BarTM
700/2s
3a95.2420.5-No-BarTMR32303T
24mil (700
mic)
No-BarTM
700/4s
3a15018Cabling-
System-
R32303T
12mil (350
mic)
"Day-light"
+ Cabling
3a203.2320.17Clear-
BarTMNo-BarTM
R32303T
24mil (700
mic)
No-Bar
700/2s +
Clear-
BarTM
Level 5 - Blast & Bullet Proof Solutions
200 k”g Anti Tank Mines – 21 meter distance
Level 5 - Blast & Bullet Proof Solutions
Canadian facility in RamallahCanadian facility in Ramallah
Blast & ballistics windows& doors
Thank you for your interest in the Al-Sorag Safety and Security Solutions.
Looking forward to doing business with you
www.al-sorag.co.il