Air ConditioningAIR CONDUCTING FANPRODUCT FLYER
Installation Examples for Large Spaces
Air Conducting Fans are supporting equipment for ventilators and air conditioners to move exhaust gas in car parks and help to improve the efficiency of ventilation or air conditioning in factories and warehouses.
Car Parks: Removing exhaust gasAir Conducting Fans are particularly useful for moving and expelling stagnant, dirty exhaust gas and hot air that stagnates in the midsections of buildings with complicated floor plans.
Warehouses and Factories: Circulating cool airAir Conducting Fans help circulate air conditioned air; they improve the working environments by reducing temperature variations throughout large indoor spaces. They enhance the effectiveness of cooling over a wider area, and the airflow they generate creates a refreshing breeze.
Air Conducting FanAH SERIES
Quiet and CompactThe compact axial fan (quiet propeller design) reduces noise level yet still makes it possible to achieve substantial airflow. The slim and lightweight design offers greater flexibility in your installation plans.
Low Power ConsumptionWith the compact and high-efficiency motor, and also the axial fan, Air Conducting Fan saves lots of energy.
Easy Installation The Air Conducting Fan can be easily installed by simply mounting it to suspension bolts on the ceiling. The angle of the air vent is adjustable to six levels.
Air Velocity Distribution
Air Conducting Fans not in use Air Conducting Fans in use
More equipments and higher installation cost
Ductsystem
Less equipments and lower installation cost
-
Ductlesssystem
0ppm
100ppm
Low
High
*Thermal distribution graphic for reference only. Actual results may differ.
Air Conducting Fans in use
Air Conducting Fans not in use
More equipments and higher installation cost
Ductsystem
Less equipments and lower installation cost
-
Ductlesssystem
0ppm
100ppm
Low
High
Temperature Distribution Using Air Conducting Fans help the air conditioned air to reach all corners, improving comfort levels.
CO DistributionThe airflow created by Air Conducting Fans allow fresh air to permeate all corners of a car park, while at the same time reliably directing the vehicle exhaust gas toward the exhaust fans.
²
LW
H
L5 - 1010 - 1515 - 2020 - 30
Model W4 - 65 - 76 - 87 - 9
AH-1006S-EAH-1509S-EAH-2009S-EAH-3009S-E
H2 - 43 - 64 - 8
5 - 10
There are cases where the reach distance is extended by angled venting, which causes the Wind to flow along the floor's surface.The Wind velocity distribution may be disturbed by enclosing walls, beams,pillars and other obstructions.Depending on conditions of the building, there may be difference in the spacingof units during installation.
AH-1006S-E
High speed
345
210
151050
0.3m/s0.5m/s1m/s
0.3m/s0.5m/s1m/s
3
321
210
150 5 10
345
2
01
3
321
210
0.3m/s0.5m/s1m/s
0.3m/s0.5m/s1m/s
Side view
Plan view
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)1050
Distance from air outlet (m)
Distance from air outlet (m)0 5 10
Distance from air outlet (m)
Side view
Plan view
Unit (mm)
Low speed
0.3m/s0.5m/s1m/s
0.3m/s0.5m/s1m/s
151050
150 5 10
345
210
3
321
210
Side view
Plan view
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)
Distance from air outlet (m)
0.3m/s0.5m/s1m/s
1m/s 0.5m/s 0.3m/s
0 5 10
0 5 10
012
123
3
012
543
Side view
Plan view
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)
Distance from air outlet (m)
0.3m/s0.5m/s1m/s
200 5 10 15012
543
Side view
Plan view
0.3m/s0.5m/s1m/s
200 5 10 15
012
123
3
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)
Distance from air outlet (m)
0.3m/s0.5m/s1m/s
0.3m/s0.5m/s1m/s
0 5 10 15
0 5 10 15012
543
012
123
3Plan view
Side view
Dist
ance
from
cen
ter (
m)
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)
Distance from air outlet (m)
AH-1509S-E
High speed Low speed
AH-2009S-E
High speed Low speed
AH-3009S-E
High speed Low speed
Plan view
Dist
ance
from
cen
ter (
m)
Distance from air outlet (m)0 10 20 30
3210123
1m/s 0.5m/s 0.3m/s
Side view
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)0 10 20 30
6543210
1m/s 0.5m/s 0.3m/s
Plan view
Dist
ance
from
cen
ter (
m)
Distance from air outlet (m)0 10 20 30
3210123
1m/s 0.5m/s 0.3m/s
Side view
Dist
ance
from
floo
r sur
face
(m)
Distance from air outlet (m)0 10 20 30
6543210
1m/s 0.5m/s 0.3m/s
* The mounting angle of the unit body can be adjusted in 8 steps. (0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90°)
Attachment details
*Figures in parentheses is the value of the AH-1509S-E and AH-2009S-E.
Internal attachment pitch
External attachment pitch
489(789)
525(825)
680(980)
716(1016)
100
12
137
58
7
600(900)
80 130
197
15380
256
190
223
Air flow
Terminal box
Unit (mm)
152
74
910
100
210
390
Power cableEffective length 1m
130
4-12x40mounting hole
Air flow
297
220
292
210
1110
1032
794
716
* The mounting angle of the unit body can be adjusted in 8 steps. (0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90°)
AH-1006/1509/2009S-E AH-3009S-E
Specifications
Model Fan Speed
Single-phase, 50Hz 220-240VStarting
Current (A)Weight (kg)
Dimensions (HxWxD)
mmAir Volume (m³/h)
Running Current (A)
Input Power (W)
Air Velocity Max. (m/sec)
Noise (dB)
AH-1006S-EHigh 700-750 0.14-0.15 30-34 6.5-6.9 42-44
0.23 7 190x600x197Low 570-620 0.13-0.13 28-32 5.3-5.7 39-40
AH-1509S-EHigh 1180-1270 0.26-0.26 55-62 7.3-7.8 43.5-45
0.43 10.5 190x900x197Low 940-1040 0.24-0.25 51.5-59 5.8-6.4 39-41.5
AH-2009S-EHigh 1350-1400 0.43-0.47 90-105 8.3-8.6 46.5-47.5
0.85 11 190x900x197Low 1130-1200 0.36-0.37 77-87 7.0-7.4 44-46
AH-3009S-EHigh 2100 0.87-0.94 191-223 8.2 58-58 2.53
20.5 210x910x220Low 1860 0.74-0.75 150-165 7.3 55.5-56 1.55