AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  1 

 

AECOsim Building Designer V8i (SELECTseries 3) to (SELECTseries 4) Delta Deployment Guide: ProjectWise V8i Managed Workspaces   Version 1.0 – May 2013 AECOsim Building Designer V8i (SELECTseries 4) with ProjectWise V8i (SELECTseries 4) or later: 

Deployment Guide Intro: 

This document:  is a delta document, highlighting the configuration changes from AECOsim Building Designer V8i, 

(SELECTseries 3) to AECOsim Building Designer V8i (SELECTseries 4). It is intended to assist users in updating their ProjectWise manage workspace to work with AECOsim Building Designer V8i (SELECTseries 4) and is a supplement to the AECOsim Building Designer V8i (SELECTseries3) Deployment Guide: ProjectWise V8i Managed Workspaces, Version 1.0/1.5. 

will provide guidance on integrating the IFC2x3 Dataset Extensions introduced in AECOsim Building Designer V8i (SELECTseries 4) with ProjectWise Manage Workspaces and ProjectWise Projects 

Restriction and Limitations of integrating Building Application in a ProjectWise Managed workspace   

AECOsim Building Designer V8i (SELECTseries 4) is compatible with a ProjectWise Integration Server V8i (SELECTseries 3) or greater but requires a ProjectWise Explorer Client (SELECTseries 4)   

 

If you have an existing ProjectWise Manage workspace deployment of AECOsim Building Designer V8i (SELECTseries 3) , Please note: The AECOsim Building Designer V8i, (SELECTseries 4)  datasets are not backwards compatible with AECOsim Building Designer V8i (SELECTseries 3).  Therefore, we encourage user to create a new and separate workspace and dataset dedicated for use with AECOsim Building Designer V8i (SELECTseries 4)  

Please reference AECOsim Building Designer V8i Deployment Guide: ProjectWise V8i Managed Workspaces, Version 1.0/1.5 for additional restrictions and limitations. 

               

ProjectWise and MicroStation are registered trademarks or trademarks of Bentley Systems, Inc., in the USA and other countries. All other brand names, product names, or trademarks belong to their respective holders.   

Page 2: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

  

 

COsim Buildin

Before Y

A4)(Scoim PBin 

  InapP D Inafinpr Thdnco 

ng Designer V

Copyrig

ou Begin 

 fully operatio) server and aSELECTseries orrespondingmplementatio

rojectWise Exentley Applicantegration for

nstall and conpplication worojectWise. U

esktop integrThe AE

ntegration witfter the instanstallation unrogram.   

he ProjectWiialog when Aot required foonsult your P

V8i Deployme

ht © 2012 Be

onal and confa defined data4) and the Prg administratoon team and/

xplorer V8i (Sation base Inr  ProjectWise

nfigure AECOsorkspace has Use this client

ration: ECOsim Buildthin the “Cusllation by initder the Wind

se Desktop InECOsim Buildor a successfurojectWise im

 

nt Guide  P

entley System

figured Projeasource mustojectWise Exor privileges a/or administra

SELECTseries 4tegration, in e Managed W

sim Building Dall the requirt to complete

ing Designertom” optionstiating the “Chdows Control 

ntegration opding Designerul ProjectWismplementatio

ProjectWise 

ms, Incorporat

ctWise integrt be availableplorer V8i Cliare also requiators before i

4) Client mustorder to fully

Workspaces. 

Designer V8i oed componen the instructi

V8i installer os during instahange” optioPanel>Progra

ens the Projeis initiated vie managed won team and/

Managed W

ted| AECOsim

ration Servere.  Access to Pent (SELECTsired. Please cinitiating Proj

t be installedy support AEC

onto a client nts for your aons in this do

offers the optllation. The ons for active ams>Program

ectWise reposia an applicatworkspace wit/or administra

Workspace 

m Building Des

V8i (SELECTsProjectWise Aeries 4) appliconsult your PjectWise Man

d to include thCOsim Buildin

workstation. application procument. 

tion to includoption can alsAECOsim Buims and Featur

sitory verses tion shortcut.th AECOsim Bators. 

signer Techno

series 3) or (SAdministratorcations with ProjectWise nage workspa

he iDesktop Inng Designer V

 

This will ensurior to import

de ProjectWisso be applied lding Designeres>Uninstall 

the standard. This step is oBuilding Desig

ote  2 

ELECTseries r V8i 

aces. 

ntegration fo8i application

ure that the ting it into 

se Desktop at any point er V8i or change 

 manager optional and gner ‐ Please 

r n 

Page 3: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  3 

 

Local Disk Space:   In a ProjectWise Managed workspace, documents from the ProjectWise Server are downloaded to the local machine and made available to the intended applications. The local machine may require a significant amount of available disk space to accommodate several projects, dataset and other supporting documents.   Once project documents are local, the exchange between the ProjectWise Server and the local machine are conducted using Delta file transfer.  Delta file transfer is a ProjectWise technology that improves performance when sending large files over networks by only sending the changes needed to update the file, rather than the entire file. This local repository can easily be managed by the Local Document Organizer, found in Project Explorer (Tools> Local Document Organizer…). 

   

Page 4: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  4 

 

Overview of Steps:  

The AECOsim Building Designer V8i, (SELECTseries 4)  datasets are not backwards compatible with AECOsim Building Designer V8i (SELECTseries 3). Therefore, we encourage user to create a new and separate workspace and dataset dedicated for use with AECOsim Building Designer V8i (SELECTseries 4). If you have invested in a customized dataset, it is always best to migrate your customization and test prior to importing them into ProjectWise.  1. Please follow all the steps (Steps 1‐7) outlined in AECOsim Building Designer V8i Deployment Guide: 

ProjectWise V8i Managed Workspaces, Version 1.0/1.5. 2. Create new Project CSBs  ‐ to enable access to Dataset Extensions. 3. Apply Dataset Extensions to a Project (two methods) 

 

   

Page 5: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  5 

 

 Step 1: Please follow all the steps (Steps 1‐7) outlined in AECOsim Building Designer V8i   Deployment Guide: ProjectWise V8i Managed Workspaces, Version 1.0/1.5  

 If you have an existing ProjectWise Manage workspace deployment of AECOsim Building Designer V8i (SELECTseries 3) , Please note: The AECOsim Building Designer V8i, (SELECTseries 4)  datasets are not backwards compatible with AECOsim Building Designer V8i (SELECTseries 3).  Therefore, we encourage user to create a new and separate workspace and dataset dedicated for use with AECOsim Building Designer V8i (SELECTseries 4).  Please follow all the steps (Steps 1‐7) outlined in AECOsim Building Designer V8i  Deployment Guide: ProjectWise V8i Managed Workspaces, Version 1.0/1.5.   

 Step 2: Create new Project CSBs 

In ProjectWise Administrator, under Workspace Profiles>Managed   

In this step, you are going to complete the following tasks: 

Create a new ‘Project’ CSB  called IFC2x3 Extension 

Create a new ‘Project’ CSB  called IFC2x3 + FM Handover Extension  The goal of the IFC2x3 dataset extension is to allow users to quickly and easily extend their projects with properly constructed and DataGroup compatible IFC 2x3 schema and property sets. Currently there are three options for this dataset extensions, all controlled by the configuration value IFC_PROJECT.    

IFC_PROJECT = 0 (default ) or Undefined– The dataset is NOT extended with any IFC2x3 Property sets and maintains the original delivered schema. 

IFC_PROJECT = 1 – The dataset is extended with the common IFC 2x3 Property Set, an extended version of the IFC ‘Coordination View’ model view definition. 

IFC_PROJECT = 2 ‐ The dataset is extended with the common IFC 2x3 Property Set, plus additional property sets as defined by the  IFC 'Facility Management Handover' model view definition and additional considerations for the COBIE (Construction Operation Business information Exchange) specification 

 

   Tip:  To learn more about COBie, Please see our “COBie User Guide” posted on BE Communities.  

   

Page 6: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

  

 

COsim Buildin

Create a 

  

ng Designer V

Copyrig

new ‘Projec(Th

1. In cli

2. In 

de

ch

 

  

V8i Deployme

ht © 2012 Be

ct’ Level CSBhis CSB will m

ProjectWise ck over the ‘P

 

the New Con

escription IFC2

ange to IFC2x

 

nt Guide  P

entley System

B called "IFCmake the vital

AdministratoPredefined’ L

nfiguration Blo

2x3 Dataset E

x3_Extension

ProjectWise 

ms, Incorporat

C2x3 Extensi connection b

or , under Woevel and sele

ock Propertie

Extension.  O

n Properties.  

Managed W

ted| AECOsim

on“  between to th

orkspace Profiect New> Conf

es, enter the n

Once complete

 

Workspace 

m Building Des

he dataset ex

iles>Managedfiguration Blo

name IFC2x3 

e click Apply.

 

signer Techno

xtensions.) 

d>Project, rigock 

Extension an

 The dialog ti

ote  6 

ght mouse 

 

nd the 

tle will 

Page 7: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

 

  

 

COsim Buildin

A

ng Designer V

Copyrig

AddVariable

3. SwVa

4. Ad 

V8i Deployme

ht © 2012 Be

etotheIFC2

witch to the Cariable. dd the followi

Name 

Description 

Add Value 

Locked 

  

nt Guide  P

entley System

2x3Extension

Configuration 

ing Variable

IFC_PRO

Enable I

OperatioValue TyValue:  1

YES 

ProjectWise 

ms, Incorporat

nCSB

tab, Select th

OJECT 

FC2x3 Datase

on Type: '='‐Aype: String 1 

Managed W

ted| AECOsim

he ‘+’ (plus) ic

et Extension

Assignment 

Workspace 

m Building Des

con and selec

signer Techno

ct the option t

  

ote  7 

to Add 

Page 8: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

 

 

 

 

COsim Buildin

A

 

ng Designer V

Copyrig

AddDirectiv

5. In 6. Ad

7. Se8. Se

V8i Deployme

ht © 2012 Be

etotheIFC2

the Configurdd the followi

Directive 

Description 

Add Value 

elect  OK on thelect  OK on th

 

nt Guide  P

entley System

2x3Extensio

ation tab, Seling Directive.

%includ

Include 

Value tyValue: $

he Modify Dirhe Project CS

ProjectWise 

ms, Incorporat

onCSB

lect the ‘+’ (p  

Dataset Conf

ype: String $(IFCDIR)data

rective dialogB’s propertie

Managed W

ted| AECOsim

lus) icon and 

figuration File

set.cfg 

g accept the des dialog to sa

Workspace 

m Building Des

 select the op

directive assigave changes 

signer Techno

ption to Add D

 

gnment 

ote  8 

Directive. 

Page 9: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  9 

 

Create a new ‘Project’ Level CSB called " IFC2x3 + FM Handover Extension “  (This CSB will make the vital connection between to the dataset extensions.) 

  1. In ProjectWise Administrator , under Workspace Profiles>Managed>Project, right mouse 

click over the ‘Predefined’ Level and select New> Configuration Block  

  

 2. In the New Configuration Block Properties, enter the name IFC2x3 + FM Handover Extension 

and the description IFC2x3 + FM Handover Dataset Extension.  Once complete click Apply. 

The dialog title will change to IFC2x3 + FM Handover Extension Properties.   

 

      

 

Page 10: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  10 

 

AddVariabletotheIFC2x3ExtensionCSB 

3. Switch to the Configuration tab, Select the ‘+’ (plus) icon and select the option to Add Variable. 

4. Add the following Variable.   

Name  IFC_PROJECT 

Description  Enable IFC2x3 + FM Handover Dataset Extension 

Add Value  Operation Type: '='‐Assignment Value Type: String Value:  2 

Locked  YES 

  

     

Page 11: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

 

 

 

 

COsim Buildin

A

ng Designer V

Copyrig

AddDirectiv

5. In 6. Ad

 7. Se8. Se

V8i Deployme

ht © 2012 Be

etotheIFC2

the Configurdd the followi

Directive 

Description 

Add Value 

elect  OK on thelect  OK on th

 

nt Guide  P

entley System

2x3Extensi

ation tab, Seling Directive.

%includ

Include 

Value tyValue: $

he Modify Dirhe Project CS

ProjectWise 

ms, Incorporat

onCSB

lect the ‘+’ (p  

Dataset Conf

ype: String $(IFCDIR)data

rective dialogB’s propertie

Managed W

ted| AECOsim

lus) icon and 

figuration File

set.cfg 

g accept the des dialog to sa

Workspace 

m Building Des

 select the op

directive assigave changes 

signer Techno

ption to Add D

gnment 

ote  11 

Directive. 

Page 12: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  12 

 

 Step 3: Apply Dataset Extensions to a Project 

  Apply Dataset Extensions to a Project   Before you can extend a project with a dataset extension in ProjectWise, you MUST first remove the configuration variable definition for IFC_PROJECT which is automatically included from importing the SELECTseries 4 project configuration files into Project CSBs  

 Back in the Configuration tab, locate the variable IFC_PROJECT, it can be found towards the bottom of the text preview panel.  Insert you cursor over the IFC_PROJECT variable. This will highlight the entire variable definition, as indicated in the image below. Then, click the “X” icon to delete this variable from the Project CSB and select ‘Apply’ to save these changes.  

       There are two methods in ProjectWise in which a project can be extended with the Dataset Extension. (Pick one) 

1. Add Directive to source Project CSB  ‐ Add either the IFC2x3 Extension or the IFC2x3 + FM Handover Extension CSB to the source Project CSB that represents the project configuration file (pcf) 

2. Add CSB to ProjectWise Project Workspace Properties (Recommend Method) ‐  Add either the IFC2x3 Extension or the IFC2x3 + FM Handover Extension CSB to ProjectWise Project workspace properties.  

 

Page 13: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

 

COsim Buildin

M

ng Designer V

Copyrig

Method1:Ad

1. In thco

2. In 3. Ad

 

  

4. Se5. Se

  

Note: 

Datase

V8i Deployme

ht © 2012 Be

ddDirective

ProjectWise e properties fonfiguration fithe Configurdd the followi

Directive 

Description 

Add Value 

elect  OK on thelect  OK on th

Any ProjectW

et Extension.

nt Guide  P

entley System

etosourceP

Administratofor the Projecile (pcf) that wation tab, Seling Directive.

%includ

Include 

Value tyValue: IF

he Modify Dirhe Project CS

Wise project a

ProjectWise 

ms, Incorporat

ProjectCSB:

or , under Wocts CSB that rwill be extendlect the ‘+’ (p  

IFC2x3 Exten

ype: ConfiguraFC2x3 Extens

rective dialogB’s propertie

associated to 

Managed W

ted| AECOsim

orkspace Profirepresent theded with onelus) icon and 

sion 

ation Setting sion: IFC2x3 D

g accept the des dialog to sa

this Project C

Workspace 

m Building Des

iles>Managede Project defin the IFC2x3 D select the op

Block Dataset Exten

  

directive assigave changes 

CSB, will inclu

signer Techno

d>Project, locnition or projDataset Extenption to Add D

sion 

gnment 

ude the define

ote  13 

cate and openect sions. Directive. 

ed IFC2x3 

Page 14: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AEC

 

 

 

 

 

COsim Buildin

M

ng Designer V

Copyrig

Method2:Ad

1. In Sw

2. Se

V8i Deployme

ht © 2012 Be

ddCSBtoPr

ProjectWise witch to the Welect the Proje

 

nt Guide  P

entley System

rojectWiseP

Explorer, locaWorkspace tabect container 

ProjectWise 

ms, Incorporat

ProjectWork

ate and openb. from the wo

Managed W

ted| AECOsim

kspaceProp

n the properti

orkspace hiera

Workspace 

m Building Des

perties(Rec

ies for the pa

archy and  

signer Techno

commendM

rent ProjectW

ote  14 

Method):

Wise Project. 

Page 15: AECOsim V8i (SELECTseries 3) to (SELECTseries 4) Delta Guide: ProjectWise V8i Managed ... · 2013-11-07 · are conducted using Delta file transfer. Delta file transfer is a ProjectWise

AECOsim Building Designer V8i Deployment Guide  ProjectWise Managed Workspace 

 

Copyright © 2012 Bentley Systems, Incorporated| AECOsim Building Designer Technote  15